Xseries 345 Type 8670 - Hardware Maintenance Manual
Xseries 345 Type 8670 - Hardware Maintenance Manual
Xseries 345 Type 8670 - Hardware Maintenance Manual
ERserver
xSeries 345 Type 8670
Hardware Maintenance Manual and Troubleshooting
Guide
ERserver
xSeries 345 Type 8670
Hardware Maintenance Manual and Troubleshooting
Guide
Eleventh Edition (February 2004)
The most recent version of this document is available on the World Wide Web at http://www.ibm.com/pc/support.
© Copyright International Business Machines Corporation 2004. All rights reserved.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract
with IBM Corp.
Contents
Chapter 1. General information . . . . . . . . . . . . . . . . . . . 1
Related publications . . . . . . . . . . . . . . . . . . . . . . . 1
Notices and statements in this book . . . . . . . . . . . . . . . . . 2
Features and specifications . . . . . . . . . . . . . . . . . . . . . 3
Server controls and indicators . . . . . . . . . . . . . . . . . . . . 4
Front view . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Server power features . . . . . . . . . . . . . . . . . . . . . . . 6
Turning on the server . . . . . . . . . . . . . . . . . . . . . . 6
Turning off the server . . . . . . . . . . . . . . . . . . . . . . 6
Standby mode . . . . . . . . . . . . . . . . . . . . . . . . 7
Chapter 3. Diagnostics . . . . . . . . . . . . . . . . . . . . . 25
General checkout . . . . . . . . . . . . . . . . . . . . . . . . 25
Diagnostic tools overview . . . . . . . . . . . . . . . . . . . . . 26
POST error logs . . . . . . . . . . . . . . . . . . . . . . . . 27
Viewing error logs from the Configuration/Setup Utility program . . . . . . 27
Viewing error logs from diagnostic programs . . . . . . . . . . . . . 28
ServerGuide error symptoms . . . . . . . . . . . . . . . . . . . . 28
Small computer system interface messages . . . . . . . . . . . . . . 28
Diagnostic programs and error messages . . . . . . . . . . . . . . . 28
Text messages . . . . . . . . . . . . . . . . . . . . . . . . 29
Starting the diagnostic programs . . . . . . . . . . . . . . . . . 30
Diagnostic error message tables . . . . . . . . . . . . . . . . . 31
Identifying problems using status LEDs . . . . . . . . . . . . . . . . 31
Power supply LEDs . . . . . . . . . . . . . . . . . . . . . . 31
Light Path Diagnostics . . . . . . . . . . . . . . . . . . . . . 32
Recovering the BIOS code . . . . . . . . . . . . . . . . . . . . 36
Power checkout . . . . . . . . . . . . . . . . . . . . . . . . 37
Troubleshooting the Ethernet controller . . . . . . . . . . . . . . . . 38
Network connection problems . . . . . . . . . . . . . . . . . . 38
Ethernet controller troubleshooting chart . . . . . . . . . . . . . . 39
Ethernet controller messages . . . . . . . . . . . . . . . . . . 40
iv xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Fan error messages . . . . . . . . . . . . . . . . . . . . . . 109
Power error messages . . . . . . . . . . . . . . . . . . . . . 109
System shutdown . . . . . . . . . . . . . . . . . . . . . . . 110
Voltage related system shutdown . . . . . . . . . . . . . . . . . 110
Temperature related system shutdown . . . . . . . . . . . . . . . 110
Hard disk drive checkout . . . . . . . . . . . . . . . . . . . . . 111
Host built-in self test (BIST) . . . . . . . . . . . . . . . . . . . . 111
Bus fault messages . . . . . . . . . . . . . . . . . . . . . . . 111
Undetermined problems . . . . . . . . . . . . . . . . . . . . . 112
Problem determination tips . . . . . . . . . . . . . . . . . . . . 113
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Contents v
vi xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Chapter 1. General information
Your IBM® Eserver xSeries® 345 Type 8670 server is a high-performance server
that can be upgraded to a symmetric multiprocessing (SMP) server through a
microprocessor upgrade. It is ideally suited for networking environments that require
superior microprocessor performance, efficient memory management, flexibility, and
reliable data storage.
The xSeries 345 server contains several IBM X-Architecture™ technologies, which
help increase server performance and reliability.
Your server comes with a limited warranty. If you have access to the World Wide
Web, you can obtain up-to-date information about your server model and other IBM
server products at http://www.ibm.com/pc/us/eserver/xseries/.
Your server serial number and model number are on labels on the bottom of the
server and on the front below the bezel. You will need these numbers when you
register your server with IBM. The information label with the serial number, machine
type, model number, and agency marks for your server are on the bottom of the
server.
Related publications
This Hardware Maintenance Manual and Troubleshooting Guide is provided in
Portable Document Format (PDF) on the IBM xSeries Documentation CD. It
contains information to help you solve the problem yourself or to provide helpful
information to a service technician.
The following types of notices and statements are used in this book:
v Note: These notices provide important tips, guidance, or advice.
v Important: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
v Attention: These notices indicate possible damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which
damage could occur.
v Caution: These statements indicate situations that can be potentially hazardous
to you. A caution statement is placed just before the description of a potentially
hazardous procedure step or situation.
v Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the
description of a potentially lethal or extremely hazardous procedure step or
situation.
2 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Features and specifications
The following table provides a summary of the features and specifications for your
server.
Table 1. Features and specifications
Microprocessor: PCI expansion slots: Security features:
v Intel™ Xeon, 3.067 GHz or higher v Two PCI-X non-hot-plug 133 MHz/64-bit v Power-on password
depending on server model v Two PCI-X non-hot-plug 100 MHz/64-bit v Remote-control security settings
v 533 MHz front-side bus (FSB) (low profile) v Selectable drive startup
v Support for up to two v One PCI non-hot-plug, 33 MHz/32-bit v Keyboard password
microprocessors with Intel v System management security
Hyper-Threading technology Integrated functions: – User login password
v IBM integrated system management – Read-only or read/write access
Memory: processor (ISMP) – Dial-in call-back
v Minimum: 512 MB, expandable to 8 – Service processor with Light Path
GB Diagnostics Predictive Failure Analysis®(PFA) alerts:
v Type: 100 MHz, PC2100 (CL2.5), – Interconnect port v Power supplies
downward compatible with PC1600 – Dedicated I/O port
(CL2), registered, ECC, double data – Support for IBM Remote Supervisor v Fans
rate (DDR), SDRAM Adapter v Memory
v Sizes: 256 MB, 512 MB, 1 GB or 2 v Two 10BASE-T/100BASE- v Hard disk drives
GB, in pairs TX/1000BASE-T Ethernet ports (Intel
v Connectors: Two-way interleaved, v Microprocessors
Ethernet controller on system board)
four dual inline memory module v One serial port v Voltage regulator modules (VRMs)
(DIMM) connectors v One external and one internal Ultra320
v Maximum: Two pairs of DIMMs Size (2 U):
SCSI port (dual-channel integrated v Height: 85.4 mm (3.36 in.)
Drives standard: controller with RAID capability) v Depth: 698 mm (27.48 in.)
v Diskette: 1.44 MB v Three Universal Serial Bus (USB) v1.1
v Width: 443.6 mm (17.5 in.)
v CD-ROM: IDE ports v Weight: 21.09 kg (46.5 lb.) to 28.12 kg (62
v Keyboard port lb.) depending upon configuration
Expansion bays: v Mouse port
v Six hot-swap, slim-high, 3.5-inch v ATI Rage XL video (controller on Heat output:
drive bays (hot-swap hard disk drives system board)
installed, some models) – Compatible with SVGA and VGA Approximate heat output in British thermal
– 8 MB video memory units (Btu) per hour
v One 5.25-inch bay (CD-ROM drive
installed) v Minimum configuration: 341 Btu/hour (100
Acoustical noise emissions:
watts)
v One 3.5-inch removable-media drive v Declared sound power, idle: 6.5 bel v Maximum configuration: 2250 Btu/hour (660
bay (diskette drive installed) v Declared sound power, operating: 6.5 watts)
bel
Hot-swap fans: Electrical input:
v Bystander sound pressure, idle: 48 dBa
v Minimum: Five v Sine-wave input (50-60 Hz) required
v Bystander sound pressure, operating: v Input voltage range automatically selected
v Maximum: Eight - provide redundant
48 dBa v Input voltage low range:
cooling
– Minimum: 90 V ac
Environment: – Maximum: 137 V ac
Hot-swap power supplies:
v Air temperature: v Input voltage high range:
350 watts (115-230 V ac) or 514 watts Maximum altitude: 2133 m (7000 ft) – Minimum: 180 V ac
(115-230 V ac) depending on server – Server on: 10° to 35°C (50° to 95°F). – Maximum: 265 V ac
model – Server off: -40° to +60°C (-40° to v Input kilovolt-amperes (kVA) approximately:
v Minimum: One 140°F). – Minimum: 0.1 kVA
v Humidity: – Maximum: 0.7 kVA
v Maximum: Two - provide redundant – Server on: 8% to 80%
power – Server off: 8% to 80% Power available for drives:
Upgradeable microcode: v +5 V dc
v +12 V dc
BIOS, diagnostics, and IBM Advanced
System Management upgrades (when
available) can update EEPROM on the
system board
Note: The illustrations in this document might differ slightly from your hardware.
Front view
SCSI or IDE
bus activity LED
Power-on
(green) Diskette drive
LED (green)
Power-control System-error activity LED
button LED (amber) (green)
Reset CD-ROM drive CD-eject button
button activity LED (green) Diskette-eject
button
Power-on LED: This green light-emitting diode (LED) is lit and stays on when you
turn on your server and flashes when the server is in Standby mode.
Attention: If the power-on LED is off, it does not mean there is no electrical
current present in the server. The LED might be burned out. To remove all electrical
current from the server, you must unplug the server power cords from the electrical
outlets or from the uninterruptible power device.
Power-control button: Press this button to manually turn on the server and put the
server in Standby mode (see “Server power features” on page 6).
Reset button: Press this button to reset the server and run the power-on self-test
(POST). You might need to use a pen or the end of a straightened paper clip to
press the button.
SCSI or IDE bus activity LED: This LED is on when there is activity on the SCSI
or IDE bus.
System-error LED: This amber LED is lit when a system error occurs. An LED on
the diagnostic LED panel will also be on to further isolate the error.
CD-ROM drive activity LED: When this LED is lit, it indicates that the CD-ROM
drive is in use.
Diskette drive activity LED: When this LED is lit, it indicates that the diskette drive
is in use.
Diskette-eject button: Press this button to release a diskette from the drive.
4 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Hard disk drive activity LED: Each of the hot-swap drives has a hard disk drive
activity LED. When this green LED is flashing, the controller is accessing the drive.
Hard disk drive status LED: Each hot-swap drive has a hard disk drive status
LED. When this amber LED is lit continuously, the drive has failed. If a RAID
adapter is installed in the server, when the LED flashes slowly (one flash per
second), the drive is being rebuilt. When the LED flashes rapidly (three flashes per
second), the controller is identifying the drive.
Information LED: This amber LED is lit when the information log contains
information about certain conditions in your server that might affect performance.
For more information, see “Diagnostic panel LEDs” on page 33.
Rear view
This section identifies the indicators on the rear of your server.
Ethernet 2 activity LED
(green)
Ethernet 2 link status LED
(green)
AC power LED
(green)
DC power LED
(green)
Ethernet 1 link status LED
(green)
Ethernet 1 activity LED
(green)
Ethernet 2 activity LED: This green LED is lit when the server is transmitting or
receiving signals to the Ethernet LAN that is connected to Ethernet port 2.
Ethernet 2 link status LED: This green LED is lit when there is an active link
connection on the 10BASE-T, 100BASE-TX, or 1000BASE-TX interface for Ethernet
port 2.
AC power LED: This green LED provides status information about the power
supply. During typical operation, both the ac and dc power LEDs are lit. For any
other combination of LEDs, see “Power supply LEDs” on page 31.
DC power LED: This green LED provides status information about the power
supply. During typical operation, both the ac and dc power LEDs are lit. For any
other combination of LEDs, see “Power supply LEDs” on page 31.
Ethernet 1 link status LED: This green LED is lit when there is an active link
connection on the 10BASE-T, 100BASE-TX, or 1000BASE-TX interface for Ethernet
port 1.
Note: You can install a circular disk over the power-control button to prevent
accidental manual power-off. This disk, known as the power-control-button shield,
comes with your server.
v If the server is turned on and a power failure occurs, it restarts automatically
when power is restored.
v You can turn on the server by using the Integrated System Management
Processor (ISMP).
v You can turn on the server by using the optional Remote Supervisor Adapter.
v If your operating system supports the Wake on LAN® feature, the Wake on LAN
feature can turn on the server.
Note: While the server is powering up, the power-on LED on the front of the server
is lit.
6 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
CAUTION:
The power control button on the device and the power switch on the
power supply do not turn off the electrical current supplied to the device.
The device also might have more than one power cord. To remove all
electrical current from the device, ensure that all power cords are
disconnected from the power source.
2
1
3. Press the power-control button on the front of the server. This will put the server
in Standby mode.
4. Disconnect the server from the power source.
Notes:
a. After you turn off the server, wait at least 5 seconds before you turn on the
server again.
b. You might need to press and hold the power-control button for more than 4
seconds to cause an immediate shutdown of the server and to force the
power off. You can use this feature if the operating system stops functioning.
Standby mode
Standby mode refers to the condition in which the server operating system is not
running and all core logic is shut down except for the service processor.
Complete the following steps to put the server into Standby mode:
1. See the operating-system documentation for the proper procedure to shut down
the operating system.
Note: Each operating system is different. Read all the documentation about
shutting down the operating system before continuing.
2. Press the power-control button on the front of the server.
You can put the server into Standby mode remotely by using the service processor.
If a later version of the ServerGuide program is available, you can download a free
image of the ServerGuide Setup and Installation CD, or you can purchase the CD.
To download the latest ServerGuide program, go to the IBM ServerGuide Web page
at http://www.ibm.com/pc/qtechinfo/MIGR-4ZKPPT.html. To purchase the latest
ServerGuide Setup and Installation CD, see the “ServerGuide Updates” flyer that
comes with your server library, or go to the ServerGuide fulfillment Web site at
http://www.ibm.com/pc/coupon/.
The ServerGuide program has the following features to make setup easier:
v An easy-to-use interface with online help
v Diskette-free setup and configuration programs that are based on detected
hardware
v A system BIOS update program, which updates the BIOS code directly from the
CD
v Device drivers that are provided for your server model and detected hardware
v NOS partition size and file-system type that are selectable during setup
System partition
The ServerGuide program creates a 50 MB system partition on the default drive.
The system partition contains server-specific utility programs such as service
processor disk operating system (DOS) utilities, system diagnostics, flash BIOS
updates, and other programs. Programs in the system partition vary by server
model, and not all server models run utility programs from the system partition. To
determine which ones do, start the ServerGuide Setup and Installation CD and view
the online overview.
After setup is complete, you can access programs in the system partition by
restarting the server and pressing Alt+F1 when the prompt is displayed. The
System Partition menu displays the programs that are available on your server
model.
Note: Features and functions can vary slightly with different versions of the
ServerGuide program.
1. After you have completed the setup process, the NOS installation program
starts. (You will need your NOS CD to complete the installation.)
2. The ServerGuide program stores information about the server model, service
processor, hard disk drive controllers, and network adapters. Then, the program
checks the CD for newer device drivers. This information is stored and then
passed to the NOS installation program.
3. With some NOS installations, you can create a NOS-replication diskette for
setting up additional servers. This diskette contains the Internet protocol (IP)
address, server name, and other selections.
4. The ServerGuide program presents NOS partition options that are based on
your NOS selection and the installed hard disk drives.
10 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
5. If you are installing the NOS from diskette, the ServerGuide program lists the
diskettes that you must create and the optional diskettes that you might want to
create. The diskettes that you can create are the device-driver diskettes for the
installed adapters or controllers.
6. The ServerGuide program prompts you to insert your NOS CD and restart the
server. At this point, the installation program for the NOS automatically
completes the installation.
Note: Availability and function can vary by server model and by the hardware that
is installed.
You can create a NOS-replication diskette, which contains information that you need
to complete multiple installations. Not all operating systems support NOS-replication
diskettes.
Using passwords
The System Security choice appears only on the full Configuration/Setup Utility
menu. After you select this choice, you can implement two levels of password
protection: power-on password and administrator password.
Power-on password
After you set a power-on password, you can enable the Unattended-Start mode.
This locks the keyboard and mouse but enables the system to start the operating
system. The keyboard and mouse remain locked until you type the correct
password.
You can use any combination of up to seven characters (A–Z, a–z, and 0–9) for
your power-on password. Keep a record of your password in a secure place. When
a power-on password is set, POST is not completed until you type the password. If
you forget the power-on password, you can regain access to the server through one
of the following methods:
v If an administrator password is set, type the administrator password at the
power-on prompt. (If necessary, see “Administrator password” for details.) Start
the Configuration/Setup Utility program, and change the power-on password.
v Remove the battery, and then reinstall the battery (see “Replacing the battery” on
page 69 for instructions).
v Change the position of the power-on password override switch (switch 6 on
switch block 1) to bypass the power-on password check. You can then start the
Configuration/Setup Utility program and change the power-on password.
Notes:
1. Before changing any switch settings or moving any jumpers, turn off the
server; then, disconnect all power cords and external cables.
2. Any system-board switch or jumper blocks that are not shown in the
illustrations in this book are reserved.
3. Changing the position of the power-on password override switch bypasses
the power-on password check the next time the server is turned on. You do
not need to move the switch back after the password is overridden. The
default position is Off. To bypass the power-on password check, move the
switch to the opposite position.
4. Changing the position of this switch does not affect the administrator
password.
Administrator password
Select this choice to set an administrator password. The administrator password
provides access to all choices on the Configuration/Setup Utility main menu.
Note: This choice is available on the Configuration/Setup Utility menu only if the
optional IBM Remote Supervisor Adapter is installed in your server.
When you use an administrator password, you can set, change, or delete both the
administrator and power-on passwords and allow a user to change a power-on
password. You can use any combination of up to seven characters (A–Z, a–z, and
0–9) for your administrator password. Keep a record of your password in a secure
place.
12 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Attention: If an administrator password is set and then forgotten, it cannot be
overridden or removed. You must replace the system board.
The information in this section provides instructions for running ServeRAID Manager
in Startable CD mode to configure your integrated SCSI controller with RAID
capabilities and perform an initial RAID configuration on your server. See the
ServeRAID documentation on the IBM ServeRAID Support CD for additional
information about RAID technology and instructions for using ServeRAID Manager
to configure your integrated SCSI controller with RAID capabilities. For information
about installing ServeRAID Manager, see the documentation on the IBM ServeRAID
Support CD.
Notes:
1. The integrated SCSI controller with RAID capabilities in your server supports
only RAID level-1 with a hot spare device. Installing an optional ServeRAID-5i
controller provides additional RAID levels. If a ServeRAID-5i controller is
installed and later removed, you must re-enable the on-board SCSI controller
using the Configuration/Setup Utility program (see “Starting the
Configuration/Setup Utility program” on page 11).
2. If you install a different type of RAID adapter in your server, use the
configuration method supplied with the RAID adapter to view or change SCSI
settings for attached devices.
To run the ServeRAID Manager program in Startable CD mode, turn on the server;
then, insert the IBM ServeRAID Support CD into the CD-ROM drive. If the
ServeRAID Manager program detects an unconfigured controller and ready drives,
the program automatically starts the Configuration wizard, and a window similar to
that shown in Figure 1 opens.
Note: If the integrated RAID controller has two channels, it will appear in the
ServeRAID Manager tree as two controller objects. However, you can configure
only one array and one RAID level-1 logical drive.
14 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
3. Click Next. The “Configuration summary” window opens.
4. Review the information that is displayed in the Configuration summary window.
To change the configuration, click Modify arrays.
5. Click Apply; then, click Yes when asked if you want to apply the new
configuration. The configuration is saved in the controller and in the physical
drives.
6. Exit from the ServeRAID Manager program and remove the CD from the
CD-ROM drive.
7. Restart the server.
4. From the list of ready drives, select the two drives you want to move to the
array.
16 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
7. Click Next. The Configuration summary window opens.
To display available actions for an item, click the item in the ServeRAID Manager
tree and click Actions.
18 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Getting assistance
For more information about ServeRAID Manager, see the online help system. To
start the help system, either click (Information about this window) on the
toolbar, or select an item from the Help menu.
The help system (ServeRAID Assist) will open within the ServeRAID Manager
interface.
20 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Complete the following steps to start the LSI Logic Configuration Utility program:
1. Turn on the server and watch the monitor screen.
2. When the Press CTRL C to start LSI Logic Configuration Utility prompt
appears, press Ctrl+C.
Note: If an administrator password has been set, a prompt appears asking you
to type the password to start the LSI Logic Configuration Utility program.
3. Use the arrow keys to select a controller (channel) from the list of adapters;
then, press Enter.
4. Follow the instructions on the screen to change the settings of the selected
items; then, press Enter.
You can use the LSI Logic Configuration Utility program to perform a low-level
format on a SCSI hard disk drive. Complete the following steps to format a drive:
Attention: The Low-Level Format program erases all data and programs. Backup
any data before running the Low-Level Format program.
1. Select the controller channel for the drive from the list of adapters.
2. Select Device Properties.
3. Use the arrow keys to highlight the drive to format.
4. Use the arrow keys or the End key to scroll to the right.
5. Highlight the Format item; then, press Enter to start.
The Ethernet connectors on the rear panel each have two LEDs. When the
Ethernet link-status LED is on, there is an active connection on the Ethernet port.
When the Ethernet transmit/receive TX/RX LED is on, there is activity between the
server and the network. For a description of the server Ethernet ports, see
t“Ethernet ports” on page 77.
When you connect the server to the network, the Ethernet controller automatically
detects the data-transfer rate (10 Mbps, 100 Mbps, or 1000Mbps) on the network
and sets the controller to operate at the appropriate rate. In addition, if the Ethernet
port that the server is connected to supports auto-negotiation, the Ethernet
controller will set the appropriate duplex state. That is, the Ethernet controller will
adjust to the network data rate, whether the data rate is standard Ethernet
(10BASE-T), Fast Ethernet (100BASE-TX), Gigabit Ethernet (1000BASE-T), half
duplex (HDX), or full duplex (FDX). The controller supports half-duplex (HDX) and
full-duplex (FDX) modes at all speeds.
The Ethernet controller is a PCI Plug and Play device. You do not need to set any
jumpers or configure the controller for the operating system before you use the
controller. However, you must install a device driver to enable the operating system
to access the controller. The device driver is provided on the ServerGuide Setup
and Installation CD.
If you install an optional Ethernet adapter or use both Ethernet ports on your server,
you can use optional modes, such as teaming, priority packets, and virtual LANs,
which provide higher performance and throughput for the server. These modes
apply to the integrated Ethernet controller and to the controllers on the supported
Ethernet adapters.
Teaming mode
Teaming options increase throughput and fault tolerance when running with
Windows NT®, Windows® 2000, or NetWare 4.1x or later.
v Adapter fault tolerance (AFT) provides automatic redundancy for the Ethernet
controller. If the primary controller fails, the optional Ethernet adapter takes over.
Adapter fault tolerance supports from 2 to 4 controllers per team.
v Adaptive load balancing (ALB) enables you to balance the transmission data
flow among 2 to 4 Ethernet controllers. ALB also includes the AFT option. You
can use ALB with any 100BASE-TX or 1000BASE-T switch.
v Cisco Fast EtherChannel (FEC) creates a team of 2 to 4 Ethernet controllers to
increase transmission and reception throughput. FEC also includes the AFT
option. You can only use FEC with a switch that has FEC capability.
22 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Priority packet prioritizes traffic based on priority filters. These are parameters you
assign to outgoing (transmit) packets. Using the Priority Filter wizard, you can set
up predefined or custom priority filters based on a node (MAC) address, Ethernet
type, or by various properties of the protocol and port. Priority packet provides two
different methods for prioritizing traffic: IEEE 802.1p tagging and high priority queue.
You can assign values to packets based on their priorities when you use the IEEE
802.1p standard for packet tagging. This method requires a network infrastructure
that supports packet tagging. The routing devices receiving and transferring these
packets on the network must support 802.1p for tagging to be effective.
After you set up the priority filter in priority packet, you must start PROSet, click the
Advanced tab, and select QoS Packet Tagging from the list.
Note: IEEE 802.1p tagging increases the size of the packets it tags. Some hubs
and switches will not recognize the larger packets and will drop them. Check the
hub or switch documentation to see if they support 802.1p. (You can configure the
switch to strip the tags from the packets and send it on to the next destination as
normal traffic.) If these devices do not support 802.1p or if you are not sure, use
high priority queue (HPQ) to prioritize network traffic.
If the network infrastructure devices do not support IEEE 802.1p or you are not
sure, you can still define filters and send packets as high priority. Although high
priority queue (HPQ) does not provide the precise priority levels of 802.1p tagging,
it does assign traffic as either high or low priority and sends high priority packets
first. Therefore, if there are multiple applications on a system sending packets, the
packets from the application with a filter are sent out first. HPQ does not change
network routing, nor does it add any information to the packets.
To assign HPQ, you can specify it using priority packet mode when you create or
assign a filter.
VLANs offer you the ability to group users and devices together into logical
workgroups. This can simplify network administration when connecting clients to
servers that are dispersed geographically across a building, campus, or enterprise
network.
Typically, VLANs are configured at the switch and any system can be a member of
one VLAN per installed network adapter. The Ethernet controller supersedes this by
communicating directly with the switch, enabling multiple VLANs on a single
network adapter (up to 64 VLANs).
When you set up VLAN membership, the Ethernet controller must be attached to a
switch that has VLAN capability. You also need to use Windows 2000, Windows NT
4.0 or later, or Novell NetWare 4.1x or later.
Notes®:
1. Windows NT versions prior to 4.0 do not support VLANs.
2. VLANs require Windows NT 4.0 with Service Pack 3.0 and the network driver
interface specifications (NDIS) driver hotfix from Microsoft®.
3. In Windows NT, VLANS cannot be implemented on controllers that have been
configured for teaming options. Netware can support teaming options and
VLANS on the same adapters.
24 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Chapter 3. Diagnostics
This section provides basic troubleshooting information to help you resolve some
common problems that might occur with your server.
If you cannot locate and correct the problem using the information in this section,
see Appendix A, “Getting help and technical assistance,” on page 123 for more
information.
General checkout
The server diagnostic programs are stored in upgradeable read-only memory
(ROM) on the system board. These programs are the primary method of testing the
major components of the server: the system board, Ethernet controller, video
controller, RAM, keyboard, mouse (pointing device), diskette drive, serial ports, and
hard disk drives. You can also use the diagnostic programs to test some external
devices. See “Diagnostic programs and error messages” on page 28.
When you run the diagnostic programs, a single problem might cause several error
messages. When this occurs, work to correct the cause of the first error message.
After you correct the cause of the first error message, the other error messages
might not occur the next time you run the test.
A failed system might be part of a shared hard disk drive cluster (two or more
systems sharing one or more external storage devices). Before you run diagnostics,
verify that the failing system is not part of a shared hard disk drive cluster.
If the failing system is suspected to be part of a shared hard disk drive cluster, run
all diagnostic tests except the diagnostic tests that test the storage unit (hard disk
drive residing in the storage unit) or the storage adapter attached to the storage
unit.
Notes:
1. For systems that are part of a shared hard disk drive cluster, run one test at a
time in looped mode. Do not run all tests in looped mode. This could enable the
hard disk drive diagnostic tests.
2. If multiple error codes are displayed, diagnose the first error code that is
displayed.
3. If the server stops with a POST error, go to “POST error codes” on page 102.
4. If the server stops and no error is displayed, go to “Undetermined problems” on
page 112.
5. For power supply problems, see “Power-supply LED errors” on page 101.
6. For safety information, see “Safety information” on page 125.
26 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
v ServerGuide error symptoms
ServerGuide error symptoms are explained at “ServerGuide error symptoms” on
page 28.
v SCSI error messages
For information on SCSI errors, see “Small computer system interface messages”
on page 28 and “SCSI error codes” on page 108.
v Diagnostic programs and error messages
The server diagnostic programs are stored in read-only memory (ROM) on the
system board. These programs are the primary method of testing the major
components of your server. See “Diagnostic programs and error messages” on
page 28 for more information.
v Light Path Diagnostics
The Light Path Diagnostics™ feature provides a series of LEDs that are built into
your server so that you can quickly identify problems with server components by
following the path of LEDs. See “Light Path Diagnostics” on page 32 for more
information.
v Error symptom charts
These charts list problem symptoms, along with suggested steps to correct the
problems. See the “Error symptoms” on page 93 for more information.
If POST finishes without detecting any problems, a single beep sounds, and the first
screen of your operating system or application program appears.
If POST detects a problem, more than one beep sounds, and an error message
appears on your screen. See “Beep symptoms” on page 83 and “POST error
codes” on page 102 for more information.
Notes:
1. If you have a power-on password or administrator password set, you must type
the password and press Enter, when prompted, before POST will continue.
2. A single problem might cause several error messages. When this occurs, work
to correct the cause of the first error message. After you correct the cause of
the first error message, the other error messages usually will not occur the next
time you run the test.
The POST error log contains the three most recent error codes and messages that
the system generated during POST. The system-error log contains all messages
issued during POST and all system status messages from the service processor.
You can view the contents of the system-error log from the Configuration/Setup
Utility program or from the diagnostic programs.
Chapter 3. Diagnostics 27
Viewing error logs from diagnostic programs
To view error logs from diagnostic programs, complete the following steps:
1. Start the diagnostic programs.
2. Select Hardware Info from the top of the diagnostic programs screen.
3. Select System Error Log from the list that appears; then, follow the instructions
on the screen.
See “Starting the diagnostic programs” on page 30 for more information.
Note: If your server does not have a hard disk drive, ignore any message that
indicates that the BIOS is not installed.
Diagnostic error messages indicate that a problem exists; they are not intended to
be used to identify a failing part. Troubleshooting and servicing of complex
problems that are indicated by error messages should be performed by trained
service personnel.
28 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Sometimes the first error to occur causes additional errors. In this case, the server
displays more than one error message. Always follow the suggested action
instructions for the first error message that appears.
The following sections contain the error codes that might appear in the detailed test
log and summary log when the diagnostic programs are run.
where:
fff is the three-digit function code that indicates the function being
tested when the error occurred. For example, function code 089 is
for the microprocessor.
ttt is the three-digit failure code that indicates the exact test failure that
was encountered. (These codes are for trained service personnel;
see “Diagnostic error codes” on page 88).
iii is the three-digit device ID. (These codes are for trained service
personnel; see “Diagnostic error codes” on page 88).
date is the date that the diagnostic test was run and the error recorded.
cc is the check value that is used to verify the validity of the
information.
text message is the diagnostic message that indicates the reason for the problem.
Text messages
The diagnostic text message format is as follows:
Function Name: Result (test specific string)
where:
Function Name
is the name of the function being tested when the error occurred. This
corresponds to the function code (fff) shown in the error code format in the
previous section.
Result
can be one of the following:
Passed This result occurs when the diagnostic test
is completed without any errors.
Failed This result occurs when the diagnostic test
discovers an error.
User Aborted This result occurs when you stop the
diagnostic test before it is complete.
Not Applicable This result occurs when you specify a
diagnostic test for a device that is not
present.
Aborted This result occurs when the test could not
proceed, for example, because of the
system configuration.
Warning This result occurs when a possible problem
Chapter 3. Diagnostics 29
is reported during the diagnostic test, such
as when a device driver is not found.
test specific string
is additional information that you can use to analyze the problem.
Note: To run the diagnostic programs, you must start the server with the
highest level password that is set. That is, if an administrator password is set,
you must enter the administrator password, not the power-on password, to run
the diagnostic programs.
2. When the message F2 for Diagnostics appears, press F2.
3. Type the appropriate password; then, press Enter.
4. Select either Extended or Basic from the top of the screen.
5. When the Diagnostic Programs screen appears, select the test you want to run
from the list that appears; then, follow the instructions on the screen.
Notes:
a. Press F1 while running the diagnostic programs to obtain help information.
Press F1 from within a help screen to obtain online documentation from
which you can select different categories. To exit from the help information
and return to where you left off, press Esc.
b. If the server stops during testing and you cannot continue, restart the server
and try running the diagnostic programs again. If the problem remains,
replace the component that was being tested when the server stopped.
c. The keyboard and mouse (pointing device) tests assume that a keyboard
and mouse are attached to the server.
d. If you run the diagnostic programs with either no mouse or a USB mouse
attached to your server, you will not be able to navigate between test
categories using the Next Cat and Prev Cat buttons. All other functions
provided by mouse-selectable buttons are also available using the function
keys.
e. You can test the USB keyboard by using the regular keyboard test. The
regular mouse test can test a USB mouse. Also, you can run the USB
interface test only if there are no USB devices attached.
f. Select Hardware Info from the top of the screen to view server configuration
information (such as system configuration, memory contents, interrupt
request (IRQ) use, direct memory access (DMA) use, device drivers, and so
on).
If the diagnostic programs do not detect any hardware errors but the problem
persists during normal server operations, a software error might be the cause. If
you suspect a software problem, see the information that comes with the software
package.
30 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Notes:
1. You can view the test log only while you are in the diagnostic programs. When
you exit the diagnostic programs, the test log is cleared (saved test logs are not
affected). To save the test log so that you can view it later, click Save Log on
the diagnostic programs screen, and specify a location and name for the saved
log file.
2. To save the test log to a diskette, you must use a diskette that you have
formatted yourself; this function does not work with preformatted diskettes. If the
diskette has sufficient space for the test log, the diskette may contain other
data.
Your server is designed so that any LEDs that are lit remain lit when the server
shuts down as long as the ac power source is good and the power supply can
supply +5 V dc current to the server. This feature helps you isolate the problem if
an error causes the server to shut down. See “Light Path Diagnostics table” on
page 34.
DC power LED
(green)
Chapter 3. Diagnostics 31
The following table describes the ac and dc power LEDs.
Possible causes:
1. The server is not turned on (the power LED is flashing on the front of
the server).
Action: Press the power-control button to start the server.
2. The power supply has failed.
Action: Replace the power supply.
Off Off There is an ac power problem.
Possible causes:
1. There is no ac power to the power supply.
Actions: Verify that:
v The electrical cord is properly connected to the server.
v The electrical outlet functions properly.
2. Disconnect the ribbon cable from connector J25 on the system board. If
the ac power LED comes on, see “Undetermined problems” on page
112.
3. The power supply has failed.
Action: Replace the power supply.
Your server is designed so that LEDs remain lit when the server shuts down, as
long as the power supply is operating properly. This feature helps you to isolate the
problem even if an error causes the server to shut down.
32 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Diagnostic panel LEDs
The following illustration shows the LEDs on the diagnostics panel inside the server.
See “Light Path Diagnostics table” on page 34 for information about identifying
problems using these LEDs.
Light Path
1 Diagnostics™
POWER
SUPPLIES
2
VRM CPU
NON
MEMORY
REDUNDANT
REMIND
OVER SPEC DASD
NMI A
PCI
ISMP B FAN
BUS
CPU/VRM
C TEMP
MISMATCH
The Light Path Diagnostics LEDs are described in the following table.
Table 4. Diagnostics panel LEDs
Diagnostic panel LED Description
POWER SUPPLY 1 The power supply in bay 1 failed.
POWER SUPPLY 2 The power supply in bay 2 failed.
VRM Error on microprocessor voltage regulator module (VRM).
CPU One or both microprocessors failed, or one is seated in the wrong socket.
NON-RED Server power supplies are no longer redundant (applicable only with redundant power
feature).
MEMORY Memory failure. One or more dual inline memory modules (DIMMs) failed.
OVER SPEC The system has shut down due to a system overload condition.
DASD The SCSI backplane or a device connected to a SCSI bus failure.
NMI Nonmaskable interrupt occurred.
PCI BUS A Error occurred on an adapter in PCI-X slots 1 or 2 or one of the integrated PCI
devices on the system board.
ISMP Integrated system-management detects an internal error.
PCI BUS B Error occurred on an adapter in PCI-X slots 3 or 4.
FAN A fan (1, 2, 3, 4, 5, 6, 7, or 8) failed or is operating slowly.
CPU/VRM MISMATCH The service processor detected a microprocessor or VRM mismatch.
PCI BUS C Error occurred on an adapter in PCI slot 5.
TEMP System temperature exceeded maximum rating.
Notes:
1. Depending on your server model, these items might appear in a different
orientation on the LED panel.
2. The server supports a maximum of three PCI buses.
3. See the documentation that comes with the system-management software for
more information about the service processor.
Chapter 3. Diagnostics 33
Remind button
You can use the Remind button to place the front panel system-error LED into the
Remind mode. By pressing the button, you acknowledge the failure but indicate that
you will not take immediate action. If a new failure occurs, the system-error LED will
turn on again.
In the Remind mode, the system-error LED flashes every 2 seconds. The
system-error LED remains in the Remind mode until one of the following situations
occurs:
v All known problems are resolved
v The system is restarted
v A new problem occurs
You can use the Remind button to delay server maintenance until a later time. Also,
resetting the system-error LED enables the LED to react to another error. If the LED
is still flashing from the first error, it will not mask additional errors.
Use the following table to help determine the cause of the error and the action you
should take when the system error LED is on and:
Table 5. Light Path Diagnostics
Diagnostics Cause Action
panel LED
on
None The system error log is 75% or more Check the system-error log, and correct any problems.
full or a PFA alert was logged. Disconnecting the server from all power sources for at least 20
seconds will turn off the system-error LED.
CPU One of the microprocessors has 1. Check the microprocessor-error LEDs on the system
failed, or a microprocessor is board. If a microprocessor-error LED is on for a
installed in the wrong socket. microprocessor socket that is empty, the microprocessors
are not installed in the correct order (see “Installing a
microprocessor” on page 59).
2. Turn off the server, reseat the microprocessor indicated by
the lit microprocessor-error LED, and restart the server.
3. If the problem remains, replace the microprocessor.
VRM One of the microprocessor VRMs has 1. Check the microprocessor VRM connectors on the system
failed. board to locate the error LED next to the failing
component. See “Installing a microprocessor” on page 59
for information about installing VRMs.
2. Turn off the server, reseat the microprocessor VRM
indicated by the lit VRM error LED, and restart the server.
3. If the problem remains, replace the microprocessor VRM.
MEMORY A memory error occurred. 1. Check the DIMM error LEDs on the system board.
2. Replace the DIMM indicated by the lit DIMM error LED.
34 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Table 5. Light Path Diagnostics (continued)
Diagnostics Cause Action
panel LED
on
PCI BUS A An error occurred on PCI bus A, B, 1. Check the adapter slots to locate the error LED next to the
or C. An adapter in PCI slot 1, 2, 3, failing bus.
PCI BUS B 4, or 5 or the system board caused 2. Check the error log for additional information.
the error. 3. If you cannot correct the problem from the error LED or
PCI BUS C information in the error log, try to determine the failing
adapter by removing one adapter at a time from PCI bus A
(PCI-X slots 1 or 2), PCI bus B (PCI-X slots 3 or 4), or PCI
bus C (PCI slot 5) and restarting the server after each
adapter is removed.
DASD A hot-swap hard disk drive has failed 1. Check the error log for additional information. If the error
on internal SCSI channel A. log indicates a temperature problem and the fans are
working correctly, verify that the ambient temperature is
within normal limits (see “Features and specifications” on
page 3).
2. If the amber hard disk status LED on one of the hot-swap
hard disk drives is on, see “Server controls and indicators”
on page 4 for more information.
NMI A nonmaskable interrupt occurred. If the PCI BUS LED is on, follow the instructions for those
The PCI BUS LED will probably also LEDs.
be on.
If the PCI BUS LED is not on, restart the server.
ISMP Integrated system management 1. Update ISMP firmware with latest level code. Unplug ac
detects an internal error. power, wait at least 30 seconds before restarting the
system.
2. System board
POWER The power supply in bay 1 has failed. Replace the power supply in bay 1.
SUPPLY 1
POWER The power supply in bay 2 has failed. Replace the power supply in bay 2.
SUPPLY 2
NON-RED The server is operating in a Check the power supply LEDs to determine the failing power
nonredundant power mode, if: supply.
v Two power supplies are installed in 1. Check the power supply connections.
the server, and one power supply 2. If a power supply has failed, replace the failing power
has either failed or is not supply.
connected to a functioning ac
3. If neither LED is lit, you can remove optional devices from
electrical outlet.
the server to restore redundancy.
v The system has exceeded the
power capabilities of one of the
redundant power supplies.
Note: This LED will not be lit if your
server has only one power supply;
however, the power is not redundant
with only one power supply installed.
FAN One of the fans has failed or is The LED on the failing fan will be lit. Replace the fan.
operating too slowly.
Note: A failing fan can also cause
the TEMP and DASD LEDs to be on.
TEMP The system temperature has 1. Check to see if a fan has failed. If it has, replace the fan.
exceeded the maximum rating. 2. Make sure the room temperature is not too high. (See
“Features and specifications” on page 3.)
Chapter 3. Diagnostics 35
Table 5. Light Path Diagnostics (continued)
Diagnostics Cause Action
panel LED
on
CPU/VRM The service processor detected a 1. Move the microprocessor in socket 1 to socket 2, and
MISMATCH microprocessor or VRM mismatch. move the microprocessor in socket 2 to socket 1.
2. Ensure that both microprocessors are of the same type,
with the same core frequency and the same L2 size.
3. Ensure that both VRMs are of the same type.
4. Ensure that both VRMs are supported in your server
model.
5. If a microprocessor is missing from socket 1, install a
microprocessor in socket 1.
None The Light Path Diagnostics feature None
has not detected a system error.
If the system error LED is off, the Light Path Diagnostics feature has not detected a
system error.
Note: You can obtain a BIOS flash diskette from one of the following sources:
v Use the ServerGuide Setup and Installation CD to make a BIOS flash diskette.
v Download a BIOS flash diskette from the World Wide Web. Go to
http://www.ibm.com/pc/support, click IBM Server Support, and make the
selections for your server.
v Contact your IBM service representative.
The flash memory of your server contains a protected area that cannot be
overwritten. The recovery boot block is a section of code in this protected area that
enables the server to start up and to read a flash diskette. The flash utility recovers
the system BIOS code from the BIOS recovery files on the diskette.
36 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
3. Locate the flash boot block recovery jumper block (J34) on the system board.
SW2
ON
8 7 6 5 4 3 2 1
System board
switch block
(SW2)
4. Move the jumper from pins 1 and 2 to pins 2 and 3 to enable the BIOS
recovery mode.
5. Insert the BIOS flash diskette into the diskette drive.
6. Reinstall the server cover; then, reconnect all power cords.
7. Restart the server. The system begins the power-on self test (POST).
8. Select 1 - Update POST/BIOS from the menu that contains various flash
update options.
9. When prompted as to whether you want to save the current code to a diskette,
press N.
10. When prompted to choose a language, select a language (from 0 to 7), and
press Enter to accept your choice.
11. Remove the BIOS flash diskette from the diskette drive.
12. Turn off the server, and disconnect all power cords and external cables; then,
remove the server cover.
13. Remove the jumper from the Flash boot block recovery jumper block, or move
it to pins 1 and 2 to return to normal startup mode.
14. Reconnect all external cables and power cords, and turn on the peripheral
devices; then, reinstall the server cover.
15. Restart the server. The server starts up normally.
Power checkout
Power problems can be difficult to solve. For example, a short circuit can exist
anywhere on any of the power distribution buses. Usually, a short circuit will cause
the power subsystem to shut down because of an overcurrent condition.
Chapter 3. Diagnostics 37
A general procedure for troubleshooting power problems is as follows:
1. Turn off the server, and disconnect all ac power cords.
2. Check for loose cables in the power subsystem. Also check for short circuits, for
example, if there is a loose screw causing a short circuit on a circuit board.
3. Remove adapters, and disconnect the cables and power connectors to all
internal and external devices until the server is at the minimum configuration
required to start the server (see “Minimum operating requirements” on page
112).
4. Reconnect all ac power cords, and turn on the server. If the server starts up
successfully, replace adapters and devices one at a time until the problem is
isolated. If the server does not start up from the minimal configuration, replace
FRUs of minimal configuration one at a time until the problem is isolated.
To use this method, it is important to know the minimum configuration required for a
system to start (see page 101). For specific problems, see “Power-supply LED
errors” on page 101.
38 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Ethernet controller troubleshooting chart
Use the following troubleshooting chart to find solutions to 10/100/1000 Mbps
Ethernet controller problems that have definite symptoms.
Table 6. Ethernet troubleshooting chart
Ethernet controller FRU/actions
problem
The server stops Check the following:
running when loading v Determine if the interrupt (IRQ) setting assigned to the Ethernet controller is also
device drivers. assigned to another device in the Configuration/Setup Utility program.
Although interrupt sharing is allowed for PCI devices, some devices do not function well
when they share an interrupt with a dissimilar PCI device. Try changing the IRQ
assigned to the Ethernet controller or the other device. For example, for NetWare
Versions 3 and 4, it is recommended that disk controllers not share interrupts with LAN
controllers.
v Make sure that you are using the most recent device driver available from the World
Wide Web.
v Run the network diagnostic program.
v Reseat or replace the adapter.
Ethernet link status LED Check the following:
is off. v Make sure that the hub is turned on.
v Check all connections at the Ethernet controller and the hub.
v Use another port on the hub.
v If the hub does not support auto-negotiation, manually configure the Ethernet controller
to match the hub.
v If you manually configured the Duplex mode, make sure that you also manually
configure the speed.
v Run diagnostics on the LEDs.
v Reseat or replace the adapter.
The Ethernet Check the following:
transmit/receive activity v Make sure that you have loaded the network device drivers.
LED is off. v The network might be idle. Try sending data from this server.
v Run diagnostics on the LEDs.
Data is incorrect or Check the following:
sporadic. v Make sure that you are using Category 5 or higher cabling when operating the server at
100 Mbps or at 1000 Mbps.
v Make sure that the cables do not run close to noise-inducing sources like fluorescent
lights.
The Ethernet controller Check the following:
stopped working when v Make sure that the cable is connected to the Ethernet controller.
another adapter was v Make sure that your PCI system BIOS code is current.
added to the server. v Reseat the adapter.
v Determine if the interrupt (IRQ) setting assigned to the Ethernet adapter is also assigned
to another device in the system. Use the Configuration/Setup Utility program to
determine if this is the case.
Although interrupt sharing is allowed for PCI devices, some devices do not function well
when they share an interrupt with a dissimilar PCI device. Try changing the IRQ
assigned to the Ethernet adapter or the other device.
v Reseat or replace the adapter.
The Ethernet controller Check the following:
stopped working without v Run diagnostics for the Ethernet controller.
apparent cause. v Try a different connector on the hub.
v Reinstall the device drivers. See your operating-system documentation and the
ServerGuide information.
v Reseat or replace the adapter.
Chapter 3. Diagnostics 39
Ethernet controller messages
The integrated Ethernet controller might display messages from certain device
drivers. The latest information available concerning these messages will be made
available at the IBM Support Web site at http://www.ibm.com/pc/support.
40 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Chapter 4. Customer replaceable units
This chapter provides instructions for adding options to your server and replacing
damaged components. Some option-removal instructions are provided in case you
need to remove one option to install another.
42 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Major components of the xSeries 345 Type 8670 server
The following illustration shows the major components in your server.
Note: The illustrations in this document might differ slightly from your hardware.
Microprocessor
air baffle
Heat sink
PCI riser card
assembly
Microprocessor
Memory module
Air baffle
System board
VRM
Hot-swap
Power-supply power supply
blank (some models)
Shuttle
Hot-swap fan
W LI
ER ES
Li ag
VR
gh no
Di
M
t st
Pa ic
NO DU SP
RE
th s™
N ND EC
OV
ER
AN
NM
T
I
SP
CP
U
CP IS
M
M
EM
U/ AT
VR CH
M
OR
DA
M
Y
SD
A
B
PC S
BU
RE
C
M
IN
D
FA
N
TE
M
P
Microprocessor 2
(J6)
ONLY
FSB CPU
533MHz
PCI-X slot 1
64-bit 3.3V
100 MHz
(J14) Microprocessor 1
(J7)
PCI-X slot 2
64-bit 3.3V
100 MHz
VRM 1
(J13)
(J8)
Battery
(BH1)
PCI riser
card
(J16)
44 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
System-board internal cable connectors
The following illustration shows the internal cable connectors on the system board.
Fans 4 and 8
(J28)
Fans 3 and 7
(J27)
USB 3
operator panel
Power signal
(J25)
Fans 2 and 6
(J29)
Fans 1 and 5
(J26)
Power
(J24)
Mouse/keyboard
(J10)
Ethernet 1
(J11)
Ethernet 2
(J12)
RS485-A and B
(J15)
USB 1
(J17)
USB 2
(J18)
External
SCSI
(J19)
ON
8 7 6 5 4 3 2 1
System board
switch block
(SW2)
The following table describes the function for each switch on the switch block.
Switch Switch
number Default value description
8 Off Reserved.
7 Off Reserved.
6 Off Reserved.
5 Off Reserved.
4 Off Reserved.
3 Off Power-on override. When toggled to On, this switch forces the power on, overriding
the power-on button.
2 Off Power-on password override. Changing the position of this switch bypasses the
power-on password check the next time the server is turned on and starts the
Configuration/Setup Utility program so that you can change or delete the power-on
password. You do not need to move the switch back to the default position after the
password is overridden.
Changing the position of this switch does not affect the administrator password check
if an administrator password is set.
See Chapter 2, “Configuring your server,” on page 9 for additional information about
the power-on password.
1 Off H8 out serial port. This switch is reserved for service use only.
46 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Notes:
1. Before changing any switch settings or moving any jumpers, turn off the server;
then, disconnect all power cords and external cables.
2. Any system-board switch or jumper blocks that are not shown in the illustrations
in this book are reserved.
Microprocessor 2
error LED (CR17)
Microprocessor 1
error LED (CR18)
Cover-release latch
Bezel
Note: You can reach the cables on the back of the server when the server is in
the locked position.
4. Lift the cover-release latch. Lift the cover off the server and set the cover aside.
Attention: For proper cooling and airflow, replace the cover before turning on
the server. Operating the server for extended periods of time (over 30 minutes)
with the cover removed might damage server components.
48 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
v You can install standard full-length adapters, with the adapter guides removed
from the adapters, in slots 3 and 4.
v You can install only a half-length adapter in slot 5.
v A ServeRAID-5i adapter can be installed only in PCI slot 2. The low-profile 2-U
bracket that comes with the controller is required to install the controller.
v The optional IBM Remote Supervisor Adapter can be installed only in PCI slot 5.
Use the ribbon cable that comes with the adapter to connect the adapter to the
system management connector on the PCI riser card.
v Your server supports 5.0 V and universal PCI adapters on the 32-bit PCI slot 5;
your server supports only 3.3 V and universal PCI adapters in the 64-bit
PCI/PCI-X slot 3 and 4.
v The PCI bus configuration is:
– Non-hot-plug, 64-bit PCI-X slots 1 and 2 (PCI bus A, 100 MHz)
– Non-hot-plug, 64-bit PCI-X slots 3 and 4 (PCI bus B, 133 MHz)
– Non-hot-plug, 32-bit PCI slot 5 (PCI bus C, 33 MHz)
v The server scans PCI and PCI-X slots 1 through 5 to assign system resources.
Then, the server starts (boots) the system devices in the following order, if you
have not changed the default boot precedence: integrated Ethernet controller,
integrated SCSI controller, and then PCI and PCI-X slots 5, 3, 4, 1, and 2.
Notes:
1. If a ServeRAID-5i adapter is installed, it takes control of the integrated SCSI
controller with RAID capabilities and operates at 66 MHz. A ServeRAID-5i
adapter can be installed only in slot 2.
2. To have SCSI capabilities if you remove the ServeRAID-5i adapter or other
RAID adapter, start the Configuration/Setup Utility program, and select
Devices and I/O Ports from the main menu to enable the SCSI controller
with RAID capabilities. See “Using the Configuration/Setup Utility program” on
page 11 for details about using the Configuration/Setup Utility program.
3. To change the startup (boot) precedence for PCI and PCI-X devices, start the
Configuration/Setup Utility program, and select Start Options from the main
menu. See “Using the Configuration/Setup Utility program” on page 11 for
details about using the Configuration/Setup Utility program.
System board
DIMM 1 DIMM 4
(J1) (J4)
DIMM 3 VRM 2
DIMM 2
(J3) (J5)
(J2)
Microprocessor 2
(J6)
PCI-X slot 1
64-bit 3.3V
100 MHz
(J14) Microprocessor 1
(J7)
PCI-X slot 2
64-bit 3.3V
100 MHz
VRM 1
(J13)
(J8)
Battery
(BH1)
PCI riser
card
(J16)
50 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
4. If you are installing an adapter in PCI slot 3, 4, or 5, remove the PCI riser-card
assembly.
a. Lift the retention latch to release the PCI riser-card assembly.
b. Lift the assembly from the server.
c. Place the assembly on a flat, level surface.
PCI riser-card
assembly
Retention
latch
Guide tab
5. Open the adapter retainer, and slide the expansion-slot cover out of the server
or PCI riser-card assembly. Store it in a safe place for future use.
Attention: Expansion-slot covers must be installed on all empty slots. This
maintains the electronic emissions characteristics of the system and ensures
proper cooling of system components.
6. See the documentation that comes with your adapter for any cabling
instructions. It might be easier for you to route cables before you install the
adapter.
7. Remove the adapter from the static-protective package.
Attention: Avoid touching the components and gold-edge connectors on the
adapter.
Adapter guide
b. Carefully grasp the adapter by its top edge or upper corners, and align it
with the expansion slot.
c. Press the adapter firmly into the expansion slot, and close the adapter
retainer.
Attention: When you install an adapter in the server, be sure that it is
completely and correctly seated in the connector. Incomplete insertion
might cause damage to the system board or the adapter.
52 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
The following illustration shows how to install a PCI or PCI-X adapter in
slots 1 and 2.
Low-profile
PCI adapter
Adapter
retainer
1 PO P
S
2
W PL
U
E IE
R S
L iag
ig n
V
D
R
h o
M
t s
P ti
N ED
ath c
O U
R
N N
O
s
V
™
D
E
A
R
N
N
T
M
P
I
E
C
S
C
P
P
U
C IS
M
P M
M
E
U A
M
/V T
O
R CH
R
M
Y
S
D
A
B
P US
C
B
R
C
E
M
IN
D
FA
N
T
E
M
P
PCI adapter
Adapter retainers
PCI riser-card
assembly
Retention
latch
Note: Make sure that the PCI riser-card assembly is properly seated on the
system-board connector and that the cables under the PCI riser-card assembly
are not pinched.
10. Connect any needed cables to the adapter. See the documentation that comes
with your adapter for cabling instructions.
Attention:
v When you route the cables, do not block the ventilated space around any of
the fans. In addition, route any cables that are plugged into the PCI adapter
under adjacent adapters so they are not pinched between the top edge of
the adapter and the shuttle side wall.
v To ensure system reliability, an optional SCSI adapter cannot control internal
hard disk drives.
54 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
v The ServeRAID-5i adapter can be installed only in PCI-X slot 2. Slot 2 is the only
PCI-X slot that supports the ServeRAID-5i adapter requirements.
v Connections made to external SCSI devices will be asynchronous.
v To have SCSI capabilities if you remove the ServeRAID-5i adapter or other RAID
adapter, start the Configuration/Setup Utility program, and select Devices and
I/O Ports from the main menu to enable the SCSI controller with RAID
capabilities. See “Using the Configuration/Setup Utility program” on page 11 for
details about using the Configuration/Setup Utility program.
Attention: To maintain proper system cooling, do not operate the server for more
than 10 minutes without either a drive or a filler panel installed in each bay.
1. Read the safety information beginning on page 125 and “System reliability
considerations” on page 41.
2. Remove the filler panel from one of the empty hot-swap bays by inserting your
finger into the depression at the left side of the filler panel and pulling it away
from the server.
3. Install the hard disk drive in the hot-swap bay:
a. Ensure that the tray handle is open (that is, perpendicular to the drive).
b. Align the drive assembly with the guide rails in the bay.
c. Gently push the drive assembly into the bay until the drive stops.
d. Push the tray handle to the closed (locked) position.
Drive-tray assembly
Drive handle
Filler panel
e. Check the hard disk drive status LED to verify that the hard disk drive is
operating properly.
If the amber hard disk drive status LED for a drive is lit continuously, that
individual drive is damaged and needs to be replaced. If the green hard disk
drive activity LED is flashing, the drive is being accessed.
Note: If you have a RAID configuration on your server using the integrated
SCSI controller with RAID capabilities, or if your server has a RAID adapter
installed, you might need to reconfigure your disk arrays after installing hard
disk drives. See the RAID documentation on the IBM xSeries Documentation
CD for information about RAID adapters.
56 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Installing memory modules
The following notes describe the types of dual inline memory modules (DIMMs) that
your server supports and other information that you must consider when installing
DIMMs:
v The system board contains four DIMM connectors and supports two-way memory
interleaving.
v The DIMM options available for your server are 256 MB, 512 MB, 1 GB, and 2
GB.
v The amount of usable memory will be reduced depending on the system
configuration. The BIOS will display the total amount of installed memory and the
amount of configured memory.
v Your server supports a minimum of two 256 MB DIMMs (for a total of 512 MB)
installed in the DIMM 1 and DIMM 2 memory connectors (J1 and J2,
respectively). When you install additional DIMMs, install them in pairs, with the
next pair in DIMM connectors 3 and 4 (J3 and J4).
v Both DIMMs in a pair must be the same size, speed, type, and technology. You
can mix compatible DIMMs from various manufacturers.
v The second pair of DIMMs do not have to be the same size, speed, type, and
technology as the first pair.
v Install only 2.5 V, 184-pin, double-data-rate (DDR), PC2100, registered
synchronous dynamic random-access memory (SDRAM) with error correcting
code (ECC) DIMMs. These DIMMs must be compatible with the latest PC2100
(and downward compatible with PC1600) SDRAM Registered DIMM
specification, which is available from http://www.jedec.org/ on the World Wide
Web. For a list of supported options for your server, go to
http://www.ibm.com/us/compat/ on the World Wide Web.
v Your server supports Chipkill technology if the DIMMs are all of the type 4x.
v Save new configuration information only if you replace a damaged DIMM that
was marked as Disabled in the Configuration/Setup Utility program Memory
Settings menu. In this case, re-enable the memory row in the
Configuration/Setup Utility program or reload the default memory settings. See
“Using the Configuration/Setup Utility program” on page 11 for more information.
v Before you begin, read the documentation that comes with your option.
v Install the DIMMs in the order shown in the following table:
Table 7. DIMM order of installation
Pair DIMM connectors
First 1 and 2 (J1, J2)
Second 3 and 4 (J3, J4)
58 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
5. To install the DIMM, repeat the following steps for each DIMM that you install:
a. Turn the DIMM so that the DIMM keys align correctly with the connector on
the system board.
Attention: To avoid breaking the retaining clips or damaging the DIMM
connectors, handle the clips gently.
b. If closed, open the retaining clips; then, insert the DIMM by pressing the
DIMM straight into the connector. Be sure that the retaining clips snap into
the closed position.
DIMM 3 (J3)
DIMM 4 (J4)
DIMM 1 (J1)
DIMM 2 (J2)
Note: If a gap exists between the DIMM and the retaining clips, the DIMM
has not been properly installed. In this case, open the retaining clips and
remove the DIMM; then, reinsert the DIMM.
Installing a microprocessor
The following notes describe the type of microprocessor that your server supports
and other information that you must consider when installing a microprocessor:
v Your server supports up to two microprocessors. With two microprocessors, your
server can operate as a symmetric multiprocessing (SMP) server. With SMP,
certain operating systems and application programs can distribute the processing
load between the microprocessors. If your server comes with one
microprocessor, you can install a second microprocessor.
v You might need to update the server BIOS code. Be sure to read the
documentation that comes with the microprocessor so that you can determine
whether you need to update the server BIOS code. You can download the latest
level of BIOS code and many other code updates for your server at
http://www.ibm.com/pc/support/ on the World Wide Web.
v (Optional) Obtain an SMP-capable operating system. For a list of supported
operating systems and other options, go to http://www.ibm.com/pc/us/compat/ on
the World Wide Web.
If your server supports a 533 MHz front-side bus, install only a microprocessor
with one pin missing from each of two adjacent corners. If your server supports a
533 MHz front-side bus, the heat-sink retention mechanism surrounding the
microprocessor connector is black.
v If the thermal-grease protective cover (for example, a plastic cap or tape liner) is
removed from the heat sink or fan sink, do not touch the thermal grease on the
bottom of the heat sink or fan sink or set down the heat sink or fan sink.
Note: Removing the heat sink or fan sink from the microprocessor destroys the
even distribution of the thermal grease and requires replacing the thermal
grease. Setting down the heat sink or fan sink onto any surface when the
thermal-grease protective cover is removed will contaminate the thermal grease.
If the thermal grease becomes contaminated with particles, it must be replaced.
For information about replacing contaminated thermal grease on the heat sink or
fan sink, contact IBM Integrated Technology Services. For the most up-to-date
phone numbers, go to http://www.ibm.com/planetwide/, or in the U.S. and
Canada, call 1-800-IBM-SERV (1-800-426-7378).
Have the following information ready when you call:
– Machine type and model
– Serial number of your server
v Do not remove the first microprocessor from the system board to install the
second microprocessor.
60 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
The following illustration is a simplified layout of the microprocessor connector
locations and other microprocessor-related components on the system board.
VRM 2 connector
(J5)
Microprocessor 2
(J6)
Microprocessor 1
(J7)
VRM 1 connector
(J8)
1 PO P
S
2
W PL
U
E IE
R S
L iag
ig n
V
D
R
h o
M
t s
P ti
N ED
ath c
O U
R
N N
O
s™
V
D
E
A
R
N
N
T
M
P
I
E
C
S
C
P
P
U
C IS
M
P M
M
E
U A
M
/V T
O
R CH
R
M
Y
S
D
A
B
P US
C
B
R
C
E
M
IN
D
FA
N
T
E
M
P
62 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
5. Install a VRM in the VRM connector (J5). See the illustration at the beginning of
these instructions for the location of the connectors:
a. Center the VRM over the connector. Make sure that the VRM is oriented
and aligned correctly.
b. Carefully but firmly push down the VRM to seat the VRM in the connector.
c. Insert one end of the retainer clip on the side of the connector, and fit the
retainer clip over the VRM. Insert the free end of the retainer clip on the
other side of the connector.
6. Locate the second microprocessor socket (connector J6) on the system board.
7. Install the microprocessor:
a. Touch the static-protective package containing the microprocessor to any
unpainted metal surface on the server. Then, remove the microprocessor
from the package.
b. Remove the protective cover, tape, or label from the surface of the
microprocessor socket, if present.
Attention: You must ensure that the locking lever on the microprocessor
socket is in the fully open position before you insert the microprocessor in
the socket. Failure to do so might result in permanent damage to the
microprocessor, microprocessor socket, and system board.
c. Rotate the locking lever on the microprocessor socket from its closed and
locked position until it stops or clicks in the fully open position
(approximately 135° angle).
Lever fully
open
Lever closed
Attention:
v Do not use excessive force when pressing the microprocessor into the
socket.
v Make sure that the microprocessor is oriented and aligned correctly with
pin number 1 in the socket before you try to close the lever.
Alignment marks
Microprocessor
socket 2
Heat sink
v Do not touch the thermal grease on the bottom of the heat sink or set down
the heat sink. Any contact with the thermal grease will contaminate it. For
details, see the thermal grease information on page 60.
a. Remove the plastic protective cover from the bottom of the heat sink.
b. Align and place the heat sink on top of the microprocessor with the thermal
grease side down. Press firmly on the heat sink.
Attention: If you do not alternate the tightening of the two captive screws,
you might damage the microprocessor. Ensure that the screws are
completely tightened; otherwise, the server will not function properly.
64 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
c. Alternate the tightening of the captive screws to secure the heat sink to the
microprocessor. Turn one screw a few turns and then turn the other screw a
few turns, alternating between the screws until the heat sink is secure.
Captive screws
Heat sink
Microprocessor
VRM
Microprocessor
release lever
9. Install the air baffle over the microprocessor section of the system board.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following label
attached.
Hazardous voltage, current, and energy levels are present inside any component that
has this label attached. There are no serviceable parts inside these components. If you
suspect a problem with one of these parts, contact a service technician.
66 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
3. Install the power supply in the bay:
a. Move the handle on the power supply into the open position, pinch the side
clip, and slide the power supply into the chassis.
b. Gently close the handle to seat the power supply in the bay.
Power supply
Handle
(open position)
AC power
LED (green)
DC power Power supply blank
LED (green) (some models)
4. Plug the power cord for the new power supply into the power-cord connector on
the power supply.
The following illustration shows the power-supply connectors on the back of the
server.
Power supply 1
power cord connector
Power supply 2
power cord connector
5. Route the power cord through the cable-management arm. (See “Installing the
server in a rack” on page 71).
6. Plug the power cord into a properly grounded electrical outlet.
7. Verify that the dc power LED and ac power LED on the power supply are lit,
indicating that the power supply is operating correctly.
Fan 7
Fan 8
Fan 1
Fan 2
Fan 5
Fan 3 Fan 4
Fan LED
1 PO P
S
2
W PL
U
E IE
R S
L iag
ig n
V
D
R
h o
M
t s
P ti
N ED
ath c
O U
R
N N
O
s™
V
D
E
A
R
N
N
T
M
P
I
E
C
S
C
P
P
U
C IS
M
P M
M
E
U A
M
/V T
O
R CH
R
M
Y
S
D
A
B
P US
C
B
R
C
E
M
IN
D
FA
N
T
E
M
P
68 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Replacing the battery
The following notes describe information that you must consider when replacing the
battery:
v IBM has designed this product with your safety in mind. The lithium battery must
be handled correctly to avoid possible danger. If you replace the battery, you
must adhere to the following instructions.
Note: In the U. S., call 1-800-IBM-4333 for information about battery disposal.
v If you replace the original lithium battery with a heavy-metal battery or a battery
with heavy-metal components, be aware of the following environmental
consideration. Batteries and accumulators that contain heavy metals must not be
disposed of with normal domestic waste. They will be taken back free of charge
by the manufacturer, distributor, or representative, to be recycled or disposed of
in a proper manner.
v To order replacement batteries, call 1-800-772-2227 within the United States, and
1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and
Canada, call your IBM reseller or IBM marketing representative.
Note: After you replace the battery, you must reconfigure your server and reset
the system date and time.
Statement 2
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has a
module containing a lithium battery, replace it only with the same module type made
by the same manufacturer. The battery contains lithium and can explode if not
properly used, handled, or disposed of.
Do not:
v Throw or immerse into water.
v Heat to more than 100° C (212° F)
v Repair or disassemble
Battery
(BH1)
10. Reinstall the adapters that you removed, and reconnect the internal cables that
you disconnected.
11. Connect all external cables and all power cords.
12. Reinstall the server cover (see “Installing the server cover and bezel” on page
71).
70 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
13. Start the Configuration/Setup Utility program, and set configuration parameters
as needed. See “Using the Configuration/Setup Utility program” on page 11 for
additional information about using the Configuration/Setup Utility program.
Attention:
v For proper cooling and airflow, replace the server cover before or shortly after
turning on the server. Operating the server for extended periods of time (over 30
minutes) with the server cover removed might damage server components.
v To ensure proper server operation, do not remove the air-baffle assembly from
the server except when installing or removing the components that are located
under the air baffle.
Cover-release latch
Bezel
Some options have device drivers that you need to install. See the documentation
that comes with your option for information about installing any required device
drivers.
Your server comes with one or two microprocessors installed on the system board.
If your server comes with two microprocessors or if your server comes with one
microprocessor and you have installed an additional microprocessor, your server
can now operate as an SMP server. Therefore, you might need to upgrade your
operating system to support SMP. See the User’s Guide on the IBM xSeries
Documentation CD and your operating-system documentation for additional
information.
If you have a RAID configuration on your server using the integrated SCSI
controller or if your server has a RAID controller installed and you have installed or
removed a hard disk drive, you might need to reconfigure your disk arrays. See the
RAID documentation on the IBM xSeries Documentation CD for information about
reconfiguring your disk arrays.
Note: If you are attaching an external SCSI device, see “Ultra320 SCSI controller
system-board connectors” on page 75 for information about SCSI cabling and SCSI
IDs.
72 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Cabling the server
Notes:
1. You must turn off the server (see “Turning off the server” on page 6) before
connecting any cables to or disconnecting any cables from the server.
2. See the documentation that comes with your options for additional cabling
instructions. It might be easier for you to route cables before you install certain
options.
3. Cable identifiers are printed on the cables that come with your server and
options. Use these identifiers to connect the cables to the correct connectors.
The following illustrations show the locations of the input and output connectors on
your server.
Rear view
Mouse
Universal Serial Bus (USB)
1 and 2
Serial
Video
Keyboard
RS 485-A
Ethernet 1 SCSI
(ISMP)
Ethernet 2 RS 485-B
(ISMP)
Front view
USB 3
Input/output ports
This section provides information about the I/O ports on the rear of your server.
These ports include the following:
v One video port
v One keyboard port
v One auxiliary-device port (pointing device) port
v One dual channel Ultra320 SCSI controller (LVD) SCSI port
v One serial port
v Three Universal Serial Bus (USB) version 1.1 ports (USB 1 and USB 2 on the
rear, USB 3 on the front)
v Two Ethernet ports
v Two RS-485 communication ports dedicated to the integrated
system-management processor (ISMP)
Note: If you install a PCI video adapter, the server BIOS will automatically disable
the integrated video controller.
The following illustration shows the 15-pin analog video connector on the rear of
your server. This connector conforms to the industry standard.
5 1
15 11
Keyboard port
There is one keyboard connector on the rear of your server.
Note: If you attach a standard (non-USB) keyboard to the keyboard connector, the
USB ports and devices will be disabled during the power-on self-test (POST).
The following illustration shows the keyboard connector on the rear of your server.
This connector conforms to the industry standard for a PS/2® keyboard.
6 5
4 3
2 1
The following illustration shows the auxiliary-device connector on the rear of your
server. This connector conforms to the industry standard for a PS/2 pointing device.
6 5
4 3
2 1
74 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Ultra320 SCSI controller system-board connectors
Your server has an integrated dual channel small computer system interface (SCSI)
controller with RAID capabilities. This controller supports two independent Ultra320
SCSI channels: one external and one internal. Each channel supports up to 15
SCSI devices. You can use the external LVD SCSI channel connector on the rear of
your server to connect different types of SCSI devices, such as drives or printers.
This controller uses:
v Double-transition clocking to achieve up to 320 MB-per-second data-transfer
rates
v Domain name validation to negotiate compatible data-transfer speeds with each
device
v Cyclic redundancy checking (CRC), instead of the usual parity checking, to
improve data reliability
v An active terminator for SCSI bus termination
The server comes with one SCSI cable, which connects the internal connector on
the system board to the standard hot-swap-drive backplane. If you plan to attach
external SCSI devices, you must order additional cables. To select and order the
correct cables for use with external devices, contact your IBM reseller or IBM
marketing representative.
SCSI IDs
Each SCSI device that is connected to a SCSI controller must have a unique SCSI
ID. This ID enables the SCSI controller to identify the device and ensure that
different devices on the same SCSI channel do not attempt to transfer data
simultaneously. SCSI devices that are connected to different SCSI channels can
have duplicate SCSI IDs. Table 8 lists the SCSI IDs for the hard disk drives and
backplanes that are connected to one channel.
Table 8. SCSI IDs for standard hot-swap hard disk drives, SCSI controller, and backplane
Device SCSI ID
Drive bay 1 0
Drive bay 2 1
Drive bay 3 2
Drive bay 4 3
Drive bay 5 4
Drive bay 6 5
SCSI controller 7
Backplane 8
The hot-swap-drive backplane controls the SCSI IDs for the internal hot-swap drive
bays. However, when you attach an external SCSI device to an optional SCSI
adapter, you must set a unique ID for the device. See the information that comes
with the device for instructions to set its SCSI ID.
68 35
Serial port
Your server has one standard serial port. Some application programs require
specific ports, and some modems function properly only at certain communication
port addresses. You might need to use the Configuration/Setup Utility program to
change communication port address assignments to prevent or resolve address
conflicts.
Note: The Devices and I/O Ports choice appears only on the full configuration
menu. If you set two levels of passwords, you must type the administrator
password to access the full configuration menu.
4. Select the serial port; then, use the arrow keys to advance through the available
settings.
5. Select Save Settings; then, select Exit Setup to exit from the
Configuration/Setup Utility main menu.
Serial-port connector
The following illustration shows the 9-pin, male D-shell serial-port connector on the
rear of your server. This connector conforms to the industry standard.
1 5
6 9
USB is a serial interface standard for telephony and multimedia devices. It uses
Plug and Play technology to determine the type of device that is attached to the
connector.
Notes:
1. If you attach a standard (non-USB) keyboard to the keyboard connector, the
USB ports and devices will be disabled during the power-on self-test (POST).
2. If you install a USB keyboard that has a mouse port, the USB keyboard
emulates a mouse, and you will not be able to disable the mouse settings in the
Configuration/Setup Utility program.
76 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
3. Check to make sure that your network operating system (NOS) supports USB
devices.
4. For additional information about USB version 1.1 devices, go to
http://www.usb.org/.
USB-port connectors
Each USB port has an external connector on the front or rear of the server for
attaching USB-compatible devices.
Ethernet ports
Your server comes with an integrated dual-port Ethernet controller. This controller
provides an interface for connecting to 10-Mbps, 100-Mbps, or 1000-Mbps networks
and provides full-duplex capability, which enables simultaneous transmission and
reception of data on the Ethernet LAN.
There are two RS-45 Ethernet connectors on the back of the server. See
“System-board external port connectors” on page 45 for the location of these
connectors.
8 1
Important: The field-replaceable unit (FRU) procedures are intended for trained
servicers who are familiar with IBM xSeries products. See the parts listing in
“System” on page 116 to determine if the component being replaced is a
customer-replaceable unit (CRU) or a FRU.
Complete the following steps to remove the hard disk drive backplane:
1. Turn off the server and any attached devices.
2. Disconnect external cables and option cables from the back of the server.
3. Remove the hard disk drives.
4. Remove the server cover (see “Removing the cover and bezel” on page 48).
5. Disconnect the two cables from the diagnostics/operator panel card.
6. Disconnect the hard disk drive cable from the backplane.
7. Disconnect the two cables from the back of the CD-ROM drive.
8. Press on the two backplane release tabs, and remove the backplane from the
server.
W PL
U
E IE
R S
L iag
ig n
V
D
R
h o
M
t s
P ti
N ED
ath c
O U
R
N N
O
s™
V
D
E
A
R
N
N
T
M
P
I
E
C
S
C
P
P
U
C IS
M
P M
M
E
U A
M
/V T
O
R CH
R
M
Y
S
D
A
B
P US
C
B
R
C
E
M
IN
D
FA
N
T
E
M
P
To replace the hard disk drive backplane, reverse the previous steps.
Note: When reinstalling the hard disk drive backplane, engage the left-most tab
first.
W PL
U
E IE
R S
L iag
ig n
V
D
R
h o
M
t s
P ti
N ED
ath c
O U
R
N N
O
s™
V
D
E
A
R
N
N
T
M
P
I
E
C
S
C
P
P
U
C IS
M
P M
M
E
U A
M
/V T
O
R CH
R
M
Y
S
D
A
B
P US
C
B
R
C
E
M
IN
D
FA
N
T
E
M
P
80 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Power-supply cage
This section contains instructions for removing and replacing the power-supply
cage.
Note: To disconnect the powr cable to the hard disk drive backplane, partially
remove the hard disk drive backplane. (See “Hard disk drive backplane” on
page 79..)
6. Remove the three screws from the power-supply cage.
Power
supply cage
Air baffle
Raised tabs
1 PO P
S
2
W PL
U
E IE
R S
L iag
ig n
V
D
R
h o
M
t s
P ti
N ED
ath c
O U
R
N N
O
s
V
™
D
E
A
R
N
N
T
M
P
I
E
C
S
C
P
ME
U
C IS
MO
P M
M
U A
/V T
RY
R CH
D
M
A
S
D
A
B
P US
C
B
R
C
E
M
IN
D
FA
N
T
E
M
P
Note: Tilt the power-supply cage during installation so that you insert the rear of
the cage first.
Note: When replacing the system board, you must either update the server
with the latest firmware or restore the pre-existing firmware that the customer
provides on a diskette or CD image.
2. Disconnect external cables and option cables from the back of the server.
3. Remove the cover (see “Removing the cover and bezel” on page 48).
4. Disconnect and remove adapters (see “Working with adapters” on page 48).
5. Disconnect all cables from the system board.
6. Remove all microprocessors and VRMs, and set them aside on a
static-protected surface for reinstallation (see “Installing a microprocessor” on
page 59).
7. Remove the memory modules, and set them aside on a static-protected surface
for reinstallation (see “Installing memory modules” on page 57).
8. Release the shuttle locking latch, and remove the shuttle from the server.
1 PO PP
SU
2
W LI
ER ES
Li iagn
VR
gh
D
M
t os
P tic
N ED
at
O U
R
N N
h s™
O
VE
DA
R
N
N
SP
T
M
I
EC
SP
C
PU
ME
C IS
MO
PU M
M
/V AT
RY
R CH
DA
M
SD
A
B
PC S
BU
R
C
EM
IN
D
FA
N
TE
M
P
Shuttle locking
latch
To replace the system board shuttle, slide the shuttle into the server and close the
shuttle locking latch. Reverse steps 4 through 7 to replace the components that
were removed.
82 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Chapter 6. Symptom-to-FRU index
This index supports xSeries 345 servers.
Notes:
1. Check the configuration before you replace a FRU. Configuration problems can
cause false errors and symptoms.
2. For IBM devices not supported by this index, refer to the manual for that device.
3. Always start with “General checkout” on page 25.
The symptom-to-FRU index lists symptoms, errors, and the possible causes. The
most likely cause is listed first. Use this symptom-to-FRU index to help you decide
which FRUs to have available when servicing the system.
The first column of the two-column tables in this index lists error codes or
messages, and the second column lists one or more suggested actions or FRUs to
replace. Take the action (or replace the FRU) suggested first in the list of the
second column, then try the server again to see if the problem has been corrected.
The POST BIOS code displays POST error codes and messages on the screen.
Beep symptoms
Beep symptoms are short tones or a series of short tones separated by pauses
(intervals without sound). See the examples in the following table.
Beeps Description
1-2-3 v One beep
v A pause (or break)
v Two beeps
v A pause (or break)
v Three beeps
4 Four continuous beeps
One beep after successfully completing POST indicates the system is functioning
properly.
Note: See “System” on page 116 to determine which components a field service technician should replace.
Beep/symptom FRU/action
1-1-2 1. Optional microprocessor (if installed)
(Microprocessor register test failed)
2. Microprocessor
3. System board
1-1-3 1. Battery
(CMOS write/read test failed)
2. System board
1-1-4 1. Recover BIOS
(BIOS EEPROM checksum failed)
2. System board
84 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Beep/symptom FRU/action
3-1-3 1. DIMM
(RAM test failed above address
2. System board
OFFFFH))
3-1-4 1. Battery
(Time-Of-Day clock failed)
2. System board
3-2-1 System board
(Serial port failed)
3-2-2 System board
(Parallel port failed)
3-2-3 1. Microprocessor
(Math coprocessor test failed)
2. System board
3-2-3 1. DIMM
(Failure comparing CMOS memory
2. Battery
size against actual)
3-3-1 1. DIMM
(Memory size mismatch occurred.)
2. Battery
3-3-2 1. Disconnect the server power cord from outlet, wait 30 seconds, and
(Critical SMBUS error occurred) retry.
2. System board.
3. DIMMs.
4. Hard disk drive backplane.
5. Power supply.
6. Power cage assembly.
7. 12C Cable.
3-3-3 1. Install or reseat the memory modules, and then do a 3 boot reset.
(No operational memory in system) (For more information on a 3 boot reset, see “Using the
Configuration/Setup Utility program” on page 11).
2. DIMMs.
3. Memory board.
4. System board.
4-4-4 (Optional system management 1. Verify that the adapter is installed in slot 1.
adapter not installed in slot 1 or not
2. Adapter.
functioning correctly)
3. System board.
Two short beeps 1. Run Diagnostics.
(Information only, the configuration
2. Run the Configuration/Setup Utility program.
has changed)
Three short beeps 1. DIMM
2. System board
One continuous beep 1. Microprocessor
2. Optional microprocessor (if installed)
3. System board
Repeating short beeps 1. Keyboard
2. System board
No-beep symptoms
Note: See “System” on page 116 to determine which components a field service technician should replace.
No-beep symptom FRU/action
No beep and the system 1. Check speaker cables.
operates correctly.
2. Speaker.
3. System board.
No beeps occur after 1. Run the Configuration/Setup Utility program, and set the Start Options
successfully completing POST Power-On Status to enable.
(the power-on status is disabled)
2. Check the speaker connection.
3. System board.
No ac power (power supply ac 1. Check the power cord.
LED is off)
2. Power supply. (If two are installed, swap them to determine if one is
defective.)
3. Disconnect the ribbon cable from connector J25 on the system board. If the
ac power LED comes on, see “Undetermined problems” on page 112.
4. Power cage assembly.
No beep and no video See “Undetermined problems” on page 112.
System will not start (power See “Power-supply LED errors” on page 101.
supply ac LED is on)
86 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
4. The DIMM error LEDs, microprocessor error LEDs, and VRM error LEDs turn
off when the system is turned off.
Note: See “System” on page 116 to determine which components a field service technician should replace.
Diagnostics panel LED FRU/action
All LEDs off 1. Check the system-error log for the error condition; then, clear the
(System-error log is 75% full; clear system-error log when the problem is found.
the log.)
2. PFA alert; check log for failure; clear PFA alert; remove ac power for at
least 20 seconds, reconnect, then turn on the system.
3. Run Light Path Diagnostics.
FAN LED on (The LED next to the 1. Failing fan.
failing fan is on.)
2. System board
MEMORY LED on (The LED next 1. Failing DIMM.
to the failing DIMM is on.)
2. System board
CPU LED on (The LED next to the 1. Run the Configuration/Setup Utility program to verify that all
failing CPU is on.) microprocessors have identical cache sizes, clock speeds and clock
frequencies.
2. Microprocessor 1 or 2.
3. System board.
PCI BUS LED on 1. Remove all PCI adapters from slots on affected bus (see
“System-board LED locations” on page 47 for bus information, see
“Working with adapters” on page 48).
2. System board.
VRM LED on (The LED next to the 1. Voltage regulator module indicated by the lit VRM LED
failing VRM is on.)
2. Microprocessor indicated by the microprocessor LED
DASD LED on (The LED located 1. Be sure the fans are operating correctly and the airflow is good.
next to the drive bay that the failing
2. If installed, reseat I2C cable between hard disk drive backplane and hard
drive is installed in is lit. Check the
disk drive I2C on the system board (J10).
amber drive LED for the failing hard
drive.) 3. Failing drive. SCSI channel A has failed. (This is the SCSI channel for the
hot-swap hard disk drives).
4. Hard disk drive backplane.
ISMP LED (Integrated System 1. Update ISMP firmware with latest level code. Unplug ac power from
Management detects an internal the server for at least 30 seconds, and then retry.
error.)
2. System board.
POWER SUPPLY 1 LED on 1. Check the dc good LED on power supply 1. If it is off, replace power
supply 1.
2. Power cage assembly.
POWER SUPPLY 2 LED on 1. Check the dc good LED on power supply 2. If it is off, replace power
supply 2.
2. Power cage assembly.
NONREDUNDANT LED on 1. Check the PS1 and PS2 LEDs and replace any indicated power supply.
2. Install an additional power supply or remove optional devices from the
server.
NMI LED on 1. Restart the server.
2. Check the system-error log.
For all error codes, replace the FRU or take the action indicated.
88 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Error code/symptom FRU/action
001-XXX-000 System board
(Failed core tests)
001-XXX-001 System board
(Failed core tests)
001-250-000 System board
(Failed system board ECC)
001-250-001 System board
(Failed system board ECC)
005-XXX-000 System board
(Failed video test)
011-XXX-000 System board
(Failed COM1 serial port test)
011-XXX-001 System board
(Failed COM2 serial port test)
014-XXX-000 System board
(Failed parallel port test)
015-XXX-001 System board
(USB interface not found, board damaged)
015-XXX-015 1. Make sure the parallel port is not disabled.
(Failed USB external loopback test)
2. Run the USB external loopback test again.
3. System board.
015-XXX-198 1. Remove USB devices from USB1 and USB2.
(USB device connected during USB test)
2. Run the USB external loopback test again.
3. System board.
020-XXX-000 System board
(Failed PCI interface test)
020-XXX-001 1. PCI hot-swap latch assembly
(Failed hot-swap slot 1 PCI latch test)
2. System board
020-XXX-002 1. PCI hot-swap latch assembly
(Failed Hot-swap slot 2 PCI latch test)
2. System board
020-XXX-003 1. PCI hot-swap latch assembly
(Failed hot-swap slot 3 PCI latch test)
2. System board
020-XXX-004 1. PCI hot-swap latch assembly
(Failed hot-swap slot 4 PCI latch test)
2. System board
030-XXX-000 System board
(Failed internal SCSI interface test)
035-XXX-099(No adapters were found.) If adapter is installed re-check connection.
035-XXX-S99 1. Adapter
(Failed RAID test on PCI slot S. S =
2. SCSI backplane
number of failing PCI slot. Check System
Error Log before replacing a FRU.) 3. Cable
035-XXX-SNN Hard disk drive with SCSI ID nn on RAID adapter in PCI slot s.
(Check System Error Log before replacing
a FRU. s = number of failing PCI slot, nn =
SCSI ID of failing fixed disk.)
90 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Error code/symptom FRU/action
166-250-000 System Management: Failed 1. If installed, reseat the I2C cable between the Remote
(I2C cable is disconnected. Reconnect I2C Supervisor Adapter (in PCI slot 5/J5 on the PCI riser card) and
cable between Remote Supervisor Adapter system-management connector on the PCI riser card.
and system board.)
2. I2C cables.
3. Advanced System Management adapter.
4. System board.
166-260-000 System Management: Failed 1. Disconnect all server and option power cords from the server,
(Restart ASM Error. After restarting, ASM wait 30 seconds, reconnect, and retry.
communication was lost. Unplug and cold
2. Reseat the Remote Supervisor Adapter in PCI slot 5/J5 on the PCI
boot to reset ASM.)
riser card.
3. Remote Supervisor Adapter.
166-342-000 System Management: Failed 1. Ensure the latest firmware levels for Remote Supervisor
(ASM adapter BIST indicate failed tests.) Adapter and BIOS.
2. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
3. Remote Supervisor Adapter.
166-400-000 System Management: Failed 1. Reflash or update firmware for ISMP.
(ISMP self test result failed tests: x where x
2. System board.
= Flash, RAM, or ROM.)
180-XXX-000 (Diagnostics LED failure) Run diagnostics panel LED test for the failing LED.
180-XXX-001 1. Operator information panel
(Failed front LED panel test)
2. System board
180-XXX-002 1. Diagnostics panel
(Failed diagnostics LED panel test)
2. System board
180-361-003 1. Fan(s)
(Failed fan LED test)
2. System board
180-XXX-003 System board
(Failed system board LED test)
180-XXX-005 1. SCSI backplane
(Failed SCSI backplane LED test)
2. SCSI backplane cable
3. System board
201-XXX-0NN 1. DIMM Location slots 1-6 where nn = DIMM location.
(Failed memory test.) Note: nn 1=DIMM 1; 2=DIMM 2; 3=DIMM 3; 4=DIMM 4.
2. System board
201-XXX-999 1. See error text for failing DIMMs.
(Multiple DIMM failure, see error text)
2. System board.
202-XXX-001 1. VRM 1
(Failed system cache test)
2. Microprocessor 1
202-XXX-002 1. VRM 2
(Failed system cache test)
2. Microprocessor 2
92 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Error code/symptom FRU/action
405-XXX-000 1. Verify that Ethernet is not disabled in BIOS.
(Failed Ethernet test on controller on the
2. System board.
system board)
405-XXX-00N 1. Adapter in PCI slot n
(Failed Ethernet test on adapter in PCI slot
2. System board
n)
415-XXX-000 1. Cable.
(Failed Modem test) Note: Ensure modem is present and attached to server.
2. Modem.
3. System board.
Error symptoms
You can use the error symptom table to find solutions to problems that have definite
symptoms.
If you cannot find the problem in the error symptom charts, go to “Starting the
diagnostic programs” on page 30 to test the server.
If you have just added new software or a new option and the server is not working,
complete the following steps before using the error symptom charts:
1. Remove the software or device that you just added.
2. Run the diagnostic tests to determine if the server is running correctly.
3. Reinstall the new software or new device.
In the following table, if the entry in the FRU/action column is a suggested action,
perform that action; if it is the name of a component, reseat the component, and
replace it if necessary. The most likely cause of the symptom is listed first.
Note: See “System” on page 116 to determine which components should be replaced by a field service technician.
CD-ROM drive problems
Symptom FRU/action
CD-ROM drive is not 1. Verify that:
recognized.
v The IDE channel to which the CD-ROM drive is attached (primary or
secondary) is enabled in the Configuration/Setup Utility program.
v All cables and jumpers are installed correctly.
v The correct device driver is installed for the CD-ROM drive.
2. Run CD-ROM drive diagnostics.
3. CD-ROM drive.
CD is not working properly. 1. Clean the CD.
2. Run CD-ROM drive diagnostics.
3. CD-ROM drive.
CD-ROM drive tray is not 1. Insert the end of a straightened paper clip into the manual tray-release
working. (The server must be opening.
turned on.)
2. Run CD-ROM drive diagnostics.
3. CD-ROM drive.
Note: See “System” on page 116 to determine which components a field service technician should replace.
Expansion enclosure problems
Symptom FRU/action
The SCSI expansion enclosure 1. Verify that:
used to work but does not work v The cables for all external SCSI options are connected correctly.
now. v The last option in each SCSI chain, or the end of the SCSI cable, is
terminated correctly.
v Any external SCSI option is turned on. You must turn on an external SCSI
option before turning on the server.
2. For more information, see your SCSI expansion enclosure documentation.
Note: See “System” on page 116 to determine which components a field service technician should replace.
General problems
Symptom FRU/action
Problems such as broken cover Broken CRU/FRU
locks or indicator LEDs not
working
Note: See “System” on page 116 to determine which components a field service technician should replace.
Hard disk drive problems
Symptom FRU/action
Not all drives are recognized by 1. Remove the first drive not recognized, and try the hard disk drive
the hard disk drive diagnostic diagnostic test again.
test (Fixed Disk test).
2. If the remaining drives are recognized, replace the drive you removed with a
new one.
System stops responding during 1. Remove the hard disk drive being tested when the server stopped
hard disk drive diagnostic test. responding, and try the diagnostic test again.
2. If the hard disk drive diagnostic test runs successfully, replace the drive you
removed with a new one.
94 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Intermittent problems
Symptom FRU/action
A problem occurs only 1. Verify that:
occasionally and is difficult to v All cables and cords are connected securely to the rear of the server and
detect. attached options.
v When the server is turned on, air is flowing from the rear of the server at the
fan grill. If there is no airflow, the fan is not working. This causes the server
to overheat and shut down.
v Ensure that the SCSI bus and devices are configured correctly and that the
last external device in each SCSI chain is terminated correctly.
2. Check the system-error log.
Note: See “System” on page 116 to determine which components a field service technician should replace.
Keyboard, mouse, or pointing-device problems
Symptom FRU/action
All or some keys on the 1. Verify that:
keyboard do not work. v The keyboard cable is securely connected to the server, and the keyboard
and mouse cables are not reversed.
v Both the server and the monitor are turned on.
2. Keyboard.
3. System board.
The mouse or pointing device 1. Verify that:
does not work.
v The mouse or pointing-device cable is securely connected, and that the
keyboard and mouse cables are not reversed.
v The mouse device drivers are installed correctly.
v Both the server and the monitor are turned on.
2. Mouse or pointing device.
3. System board.
Note: See “System” on page 116 to determine which components a field service technician should replace.
Microprocessor problems
Symptom FRU/action
The server emits a continuous 1. Verify that the startup microprocessor is seated properly.
tone during POST. (The startup
2. Startup microprocessor.
(boot) microprocessor is not
working properly.)
96 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Monitor problems
Symptom FRU/action
Testing the monitor. See the information that comes with the monitor for adjusting and testing
instructions. (Some IBM monitors have their own self-tests.)
The screen is blank. 1. Verify that:
v The server power cord is plugged into the server and a working electrical
outlet.
v The monitor cables are connected properly.
v The monitor is turned on and the Brightness and Contrast controls are
adjusted correctly.
v If the servers are C2T chained together, verify that:
– The C2T chain cables are securely connected to the servers.
– The C2T breakout cable is connected properly.
– A server that is turned on is selected.
Important: In some memory configurations, the 3-3-3 beep code might sound
during POST followed by a blank display screen. If this occurs and the Boot
Fail Count feature in the Start Options of the Configuration/Setup Utility
program is set to Enabled (its default setting), you must restart the server three
times to force the system BIOS code to reset the CMOS values to the default
configuration (memory connector or bank of connectors enabled).
2. If you have verified these items and the screen remains blank, replace:
a. Monitor
b. Video adapter, if installed
c. System board
Only the cursor appears. See “Undetermined problems” on page 112.
The monitor works when you 1. Verify that:
turn on the computer but goes
v The application program is not setting a display mode higher than the
blank when you start some
capability of the monitor.
application programs.
v The primary monitor cable is connected to the C2T device breakout cable.
v You installed the necessary device drivers for the applications.
2. If you have verified these items and the screen remains blank, replace the
monitor.
3. Video adapter.
4. System board.
98 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Option problems
Symptom FRU/action
An IBM option that was just 1. Verify that:
installed does not work. v The option is designed for the server (see the ServerProven® list on the
World Wide Web at http://www.ibm.com/pc/compat/).
v You followed the installation instructions that came with the option.
v The option is installed correctly.
v You have not loosened any other installed options or cables.
v You updated the configuration information in the Configuration/Setup Utility
program. Whenever memory or an option is changed, you must update the
configuration.
2. Option you just installed.
An IBM option that used to work 1. Verify that all of the option hardware and cable connections are secure.
does not work now.
2. If the option comes with its own test instructions, use those instructions to test
the option.
3. If the failing option is a SCSI option, verify that:
v The cables for all external SCSI options are connected correctly.
v The last option in each SCSI chain, or the end of the SCSI cable, is
terminated correctly.
v Any external SCSI option is turned on. You must turn on an external SCSI
option before turning on the server.
4. Failing option.
Note: See “System” on page 116 to determine which components a field service technician should replace.
Power problems
Symptom FRU/action
Power switch does not work 1. Reseat connector.
and reset button, if supported,
2. Power switch card.
does work.
3. System board.
The server does not turn on. 1. Verify that:
v The power cables are properly connected to the server.
v The electrical outlet functions properly.
v The type of memory installed is correct.
v If you just installed an option, remove it, and restart the server. If the server
now turns on, you might have installed more options than the power supply
supports.
2. Override front panel power button:
a. Disconnect server power cords.
b. Reconnect power cords.
If server turns on: Operator information panel
If server does not turn on: System board
3. See “Undetermined problems” on page 112.
Note: See “System” on page 116 to determine which components a field service technician should replace.
Serial port problems
Symptom FRU/action
The number of serial ports 1. Verify that:
identified by the operating v Each port is assigned a unique address by the Configuration/Setup Utility
system is less than the number program, and none of the serial ports is disabled.
of serial ports installed. v The serial-port adapter, if you installed one, is seated properly.
2. Failing serial port adapter.
A serial device does not work. 1. Verify that:
For more information about the v The device is compatible with the server.
serial port, see “Serial port” on v The serial port is enabled and is assigned a unique address.
page 76. v The device is connected to the correct port (see “Input/output ports” on page
73).
2. Failing serial device.
3. Serial adapter, if installed.
4. System board.
Note: See “System” on page 116 to determine which components a field service technician should replace.
Software problem
Symptom FRU/action
Suspected software problem. 1. To determine if problems are caused by the software, verify that:
v The server has the minimum memory needed to use the software. For
memory requirements, see the information that comes with the software.
Note: If you have just installed an adapter or memory, you might have a
memory address conflict.
v The software is designed to operate on the server.
v Other software works on the server.
v The software that you are using works on another server.
If you received any error messages when using the software program, see the
information that comes with the software for a description of the messages and
suggested solutions to the problem.
2. If you have verified these items and the problem remains, contact your place of
purchase.
100 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Universal Serial Bus (USB) port problems
Symptom FRU/action
A USB device does not work. Verify that:
v You are not trying to use a USB device during POST if you have a standard
(non-USB) keyboard attached to the keyboard port.
Note: If a standard (non-USB) keyboard is attached to the keyboard port, the
USB is disabled and no USB device will work during POST.
v The correct USB device driver is installed.
v The operating system supports USB devices.
Note: The minimum configuration required for the dc good light to be lit is:
v Power supply
v Power cage assembly.
v System board (set switch 3 of SW2 to bypass the power switch; see
“System-board switches and jumpers” on page 46).
Note: See “System” on page 116 to determine which components a field service technician should replace.
AC good LED DC good LED Description FRU/action
Off Off No power to system or ac 1. Check ac power to the system.
problem.
2. Disconnect the ribbon cable from connector
J25 on the system board. If the ac power
LED comes on, see “Undetermined
problems” on page 112.
3. Power supply.
On Off Standby mode or dc 1. Check system board cable connectors
problem. J4 and J10. Move switch 3 of SW 1 to
bypass power control. If the dc good LED
is lit, press Ctrl+Alt+Delete. Watch the
screen for any POST errors. Check the
system-error log for any listed problems. If
the system starts with no errors:
a. Power switch assembly
b. System board
2. Remove the adapters, and disconnect the
cables and power connectors to all internal
and external devices. Turn on the system.
If the dc good LED is lit, replace the
adapters and devices one at a time until
you isolate the problem.
3. Power supply.
4. Power cage assembly.
5. System board.
On On Power is working properly. N/A
Note: See “System” on page 116 to determine which components a field service technician should replace.
Error code/symptom FRU/action
062 1. Run the Configuration/Setup Utility program.
(Three consecutive startup failures using
2. Battery.
the default configuration.)
3. System board.
4. Microprocessor.
101, 102 System board
(System and processor error)
106 System board
(System and processor error)
111 1. Memory DIMM
(Channel check error)
2. System board
114 1. Failing adapter.
(Adapter read-only memory error)
2. Run diagnostics.
129 1. Microprocessor
(Internal cache error)
2. Optional microprocessor (if installed)
151 1. Run diagnostics.
(Real time clock error)
2. Battery.
3. System board.
161 1. Run the Configuration/Setup Utility program.
(Real time clock battery error)
2. Battery.
3. System board.
162 1. Run the Configuration/Setup Utility program.
(Device configuration error)
2. Battery.
Note: Be sure to load the default settings
and any additional desired settings; then, 3. Failing device.
save the configuration. 4. System board.
163 1. Run the Configuration/Setup Utility program.
(Real-time clock error)
2. Battery.
3. System board.
164 1. Run the Configuration/Setup Utility program.
(Memory configuration changed.)
2. DIMM.
3. System board.
175 System board
(Hardware error)
176 1. Run the Configuration/Setup Utility program.
(Computer cover or cable cover was
2. System board.
removed without a key being used)
177, 178 1. Run the Configuration/Setup Utility program.
(Security hardware error)
2. System board.
184 1. Run the Configuration/Setup Utility program.
(Power-on password damaged)
2. System board.
102 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Error code/symptom FRU/action
185 1. Run the Configuration/Setup Utility program.
(Drive startup sequence information
2. System board.
corrupted)
186 1. Run the Configuration/Setup Utility program.
(Security hardware control logic failed)
2. System board.
187 1. Set serial number in the Configuration/Setup Utility program.
(VPD serial number not set.)
2. System board.
188 1. Run the Configuration/Setup Utility program.
(Bad EEPROM CRC #2)
2. System board.
189 Run the Configuration/Setup Utility program, and type the
(An attempt was made to access the administrator password.
server with invalid passwords)
201 1. DIMM
(Memory test error.) If the server does not
2. System board
have the latest level of BIOS installed,
update the BIOS to the latest level and
run the diagnostic program again.
229 1. Microprocessor
(Cache error)
2. Optional microprocessor (if installed)
262 1. Run the Configuration/Setup Utility program.
(DRAM parity configuration error)
2. Battery.
3. System board.
289 1. Run the Configuration/Setup Utility program, if the DIMM was
(DIMM disabled by POST or user) disabled by the user.
2. Disabled DIMM, if not disabled by user.
301 1. Keyboard
(Keyboard or keyboard controller error)
2. System board
303 System board
(Keyboard controller error)
602 1. Diskette
(Invalid diskette boot record)
2. Diskette drive
3. Cable
4. System board
604 1. Run the Configuration/Setup Utility program and diagnostics.
(Diskette drive error)
2. Diskette drive.
3. Drive cable.
4. System board.
605 1. Diskette drive
(Unlock failure)
2. Drive cable
3. System board
104 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Error code/symptom FRU/action
1601 1. Remote Supervisor Adapter, if installed
(The system is able to communicate to the
2. System board
system management processor, but the
system management processor failed to
respond at the start of POST.) Complete
the following steps before replacing a
FRU:
1. Remove the ac power to the server,
wait 20 seconds; then, reconnect the
ac power. Wait 30 seconds; then, turn
on the server.
2. Flash update the system management
processor.
1602 Disconnect all server and option power cords from server, wait 30
(Cable for optional service processor seconds, reconnect, and retry.
adapter not installed)
1762 1. Hard disk drive.
(Hard disk configuration error)
2. Hard disk cables.
3. Run the Configuration/Setup Utility program.
4. Hard disk adapter.
5. SCSI backplane.
6. System board.
178X 1. Hard disk cables.
(Fixed disk error)
2. Run diagnostics.
3. Hard disk adapter.
4. Hard disk drive.
5. System board.
1800 1. Run the Configuration/Setup Utility program.
(No more hardware interrupt available for
2. Failing adapter.
PCI adapter)
3. System board.
1962 1. Verify that a startable operating system is installed.
(Drive does not contain a valid boot
2. Run diagnostics.
sector)
3. Hard disk drive.
4. SCSI backplane.
5. Cable.
6. System board.
2400 1. Video adapter (if installed)
(Video controller test failure)
2. System board
2462 1. Video adapter (if installed)
(Video memory configuration error)
2. System board
106 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Error code/symptom FRU/action
00180500 1. Remove failing PCI card.
(PCI option ROM checksum error)
2. System board.
00180600 1. Run the Configuration/Setup Utility program.
(PCI to PCI bridge error)
2. Move the failing adapter to slot 1.
3. Failing adapter.
4. System board
00180700, 00180800 1. System board
(General PCI error)
2. PCI card
00181000 1. Adapter
(PCI error)
2. System board
01295085 1. System board
(ECC checking hardware test error)
2. Microprocessor
01298001 1. Ensure all processors have the same cache size.
(No update data for microprocessor 1)
2. Microprocessor 1.
01298002 1. Ensure all microprocessors have the same cache sizes, clock
(No update data for microprocessor 2) speeds and clock frequencies.
2. Microprocessor 2.
01298101 1. Ensure all microprocessors have the same cache sizes, clock
(Bad update data for microprocessor 1) speeds and clock frequencies.
2. Microprocessor 1.
01298102 1. Ensure all microprocessors have the same cache sizes, clock
(Bad update data for microprocessor 2) speeds and clock frequencies.
2. Microprocessor 2.
I9990301 1. Hard disk drive
(Hard disk sector error)
2. SCSI backplane
3. Cable
4. System board
I9990305 Install operating system to hard disk.
(Hard disk sector error, no operating
system installed)
I9990650 1. Check cable.
(AC power has been restored)
2. Check for interruption of power.
3. Power cable.
108 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Message Action
System over temperature for CPU x Ensure that the server is being properly cooled; see “System
(level-warning; CPU x reporting over reliability considerations” on page 41.
temperature condition)
System under recommended CPU x Ambient temperature must be within normal operating
temperature (level-warning; system specifications; see “Features and specifications” on page 3.
reporting under temperature condition for
CPU x)
System shutdown
Refer to the following tables when experiencing system shutdown related to voltage
or temperature problems.
110 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Note: See “System” on page 116 to determine which components a field service technician should replace.
Message Action
System shutoff due to high ambient Ambient temperature must be within normal operating
temperature specifications; see “Features and specifications” on page 3.
(level-critical; high ambient temperature)
System shutoff due to system board Ambient temperature must be within normal operating
under temperature specifications; see “Features and specifications” on page 3.
(level-critical; system board is under
temperature)
Undetermined problems
Use the information in this section if the diagnostic tests did not identify the failure,
the devices list is incorrect, or the system is inoperative.
Notes:
1. Damaged data in CMOS can cause undetermined problems.
2. Damaged data in BIOS code can cause undetermined problems.
Check the LEDs on all the power supplies. If the LEDs indicate the power supplies
are working correctly, complete the following steps:
1. Turn off the server.
2. Be sure the server is cabled correctly.
3. Remove or disconnect the following devices (one at a time) until you find the
failure (turn on the server and reconfigure each time):
Any external devices
Surge suppressor device (on the server)
Modem, printer, mouse, or non-IBM devices
Each adapter
Drives
Memory modules (minimum requirement = 256 MB (2 banks of 128 MB
DIMMs))
112 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Problem determination tips
Due to the variety of hardware and software combinations that can be encountered,
use the following information to assist you in problem determination. If possible,
have this information available when requesting assistance from Service Support
and Engineering functions.
v Machine type and model
v Microprocessor or hard disk upgrades
v Failure symptom
– Do diagnostics fail?
– What, when, where, single, or multiple systems?
– Is the failure repeatable?
– Has this configuration ever worked?
– If it has been working, what changes were made prior to it failing?
– Is this the original reported failure?
v Diagnostics version — type and version level
v Hardware configuration
– Print (print screen) configuration currently in use
– BIOS level
v Operating system software type and version level
18
3
17 4
15
6
7
16 9
8
14
1 PO PP
SU
2
W LI
ER ES
Li iagn
VR
gh
D
M
t os
Pa tic
NO DU SP
RE R
th s™
N ND EC
O
VE
AN
NM
T
I
SP
CP
ME
U
CP IS
MO
M
U/ AT
RY
VR CH
M
DA
M
SD
A
B
PC S
BU
RE
C
M
IN
D
FA
N
TE
M
P
10
13
11
12
Server (xSeries 345, Type 8670) Models 11X, 12X, 21X, 22X, 23X,
24X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 71X, 72X,
Index 7RG, 91X, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X FRU No. CRU/FRU
1 Microprocessor air baffle (models 11X, 12X, 21X, 22X, 23X, 31X, 32X, 24P1284 CRU
3PX, 3WX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX,
G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X, )
2 Heat-sink assembly, microprocessor (all models) 25P6309 FRU
3 Microprocessor, 2.0 GHz (models 11X, 12X) 25P2671 FRU
3 Microprocessor, 2.0 GHz/533 MHz 2 MB (model J1X) 25P2671 FRU
3 Microprocessor, 2.2 GHz (models 21X, 22X, 23X) 32P8582 FRU
3 Microprocessor, 2.4 GHz (models 24X, 31X, 32X) 37L3570 FRU
3 Microprocessor, 2.4 GHz (models 3PX, 3WX, 3YX, 3ZX) 59P4937 FRU
3 Microprocessor, 2.67 GHz (models 51X, 52X, K1X, K2X) 59P4840 FRU
3 Microprocessor, 2.8 GHz (models 61X, 62X L1X, L2X) 59P4845 FRU
3 Microprocessor, 3.0 GHz (models 71X, 72X, 7RX M1X, M2X) 71P8340 FRU
3 Microprocessor, 3.0 GHz (models 91X, 9RX, F1X, FRX) 88P9782 FRU
3 Microprocessor, 3.2 GHz (model G1X) 90P0969 FRU
4 Memory, 256 PC2100 ECC (models 11X, 12X, 21X, 22X, 31X, 32X, 09N4306 CRU
3WX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX, G1X,
K1X, K2X, L1X, L2X, M1X, M2X)
4 Memory, 256 PC2100 (models F1X, FRX, K1X, K2X, L1xX, L2X, 73P2872 CRU
M1X, M2X)
4 Memory, 512 MB PC2100 ECC (models 23X, 3PX, 3YX, 3ZX, G1X) 09N4307 CRU
4 Memory, 1 GB PC2100 ECC (model 24X) 09N4308 CRU
5 VRM card 9.05P (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X) 49P2129 FRU
5 VRM card 9.1 (models 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, 49P2010 FRU
9RX, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X)
6 Power-supply filler panel (models 11X, 21X, 31X) 01R0601 CRU
6 Power-supply filler panel (models 71X, 91X,FLX, G1X, J1X, M1X) 73P6163 CRU
7 Hot-swap power supply, 350 watt (models 11X, 12X, 21X, 22X, 23X, 49P2033 CRU
24X, 31X, 32X, 51X, 52X, 61X, 62X, K1X, K2X, L1X, L2X)
7 Hot-swap power supply, 514 watt (models 71X, 91X, 72X, 7RG, 9RX, 49P2167 CRU
F1X, FRX, G1X, J1X, M1X, M2X)
8 System board shuttle assembly (models 11X, 12X, 21X, 22X, 23X, 23K4454 FRU
24X, 31X, 32X)
8 System board shuttle assembly (models 3PX, 3WX, 3YX, 3ZX, 51X, 23K4455 FRU
52X, 61X, 62X, K1X, K2X, L1X, L2X)
8 System board shuttle assembly (models 71X, 72X, 7RGX, 91X, 9RX, 23K4456 FRU
F1X, FRX, G1X, J1X, M1X, M2X )
9 Power cage assembly (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 49P2037 FRU
32X, 51X, 52X, 61X, 62X, K1X, K2X, L1X, L2X)
9 Power cage assembly (models 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, 49P2169 FRU
G1X, J1X, M1X, M2X)
10 Chassis (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 3PX, 3WX, 01R0588 FRU
3YX, 3ZX, 51X, 52X, 61X, 62X, 7RG, 91X, F1X, FRX, G1X, K1X,
K2X, L1X, L2X)
10 Chassis (models 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, 73P6161 FRU
M1X, M2X)
11 Front bezel assembly (models 11X, 12X, 21X, 22X, 31X, 32X, 3PX, 32P1878 CRU
3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X,
FRX, G1X, K1X, K2X, L1X, L2X, M1X, M2X)
116 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Server (xSeries 345, Type 8670) Models 11X, 12X, 21X, 22X, 23X,
24X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 71X, 72X,
Index 7RG, 91X, F1X, FRX, G1X, J1X, K1X, K2X, L1X, L2X, M1X, M2X FRU No. CRU/FRU
11 Front bezel assembly (model 23X) 01R0664 CRU
11 Front bezel assembly (model 24X) 01R0682 CRU
11 Front bezel assembly (models 3PX, 3WX, 3YX, 3ZX) 73P6635 CRU
12 Hard disk drive, 36 GB (models 12X, 22X, 32X) 06P5778 CRU
12 Hard disk drive, 36 GB (models 3PX, 3WX, 3YX, 3ZX) 90P1341 CRU
12 Hard disk drive, 36 GB (models 52X, 62X, 72X, 7RG, 9RX, FRX, K2X, 32P0729 CRU
L2X, M2X)
12 Hard disk drive, 73 GB (model 3ZX) 90P1340 CRU
12 Hard disk drive, 73 GB (models 23X, 24X) 32P0759 CRU
13 Blank bezel, hard disk drive (all models) 00N7259 CRU
13 Blank bezel, hard disk drive (models 11X, 12X, 21X, 22X, 31X, 32X, 06P6245 CRU
51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X,
K1X, K2X, L1X, L2X, M1X, M2X)
14 Hard disk drive backplane with bracket assembly (all models) 59P5856 FRU
15 Thermal baffle kit (all models) 01R0614 FRU
16 Fan assembly, 80-mm hot-swap (all models) 01R0587 CRU
17 PCI riser card assembly (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 48P9027 FRU
32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 7RG, 91X, F1X,
FRX, G1X, K1X, K2X, L1X, L2X)
17 PCI riser card assembly (model 71x, 72x, 7RG, 91X, 9RX, F1x FRX, 73P6591 FRU
G1X, J1X, M1X, M2X)
18 Top cover (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 3PX, 01R0595 CRU
3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 7RG, 91X, F1X, FRX, G1X,
J1X, K1X, K2X, L1X, L2X, M1X, M2X)
18 Top cover (models 71X, 72X, 7RG, 91X, 9RX, F1X, FRX, G1X, J1X, 73P6162 CRU
M1X, M2X)
Alcohol wipe kit (all models) 59P4739 FRU
Thermal grease kit (all models) 59P4740 FRU
Baffle, memory DIMM (models 41X, 51X, 52X, 61X, 62X, 71X, 72X, 90P4079 FRU
7RG, K1X, K2X, L1X, L2X)
Battery (all models) 33F8354 FRU
Battery pack, RAID adapter (models 12X, 22X, 32X, 52X, 62X, 72X, 25P3482 FRU
K2X, L2X, M2X)
Battery pack, 3U/2U (models 7RG, 9RX, FRX) 02R0986 FRU
Cable-IDE, 2-drop (models 23X, 24X) 01R0636 CRU
Cable-management-arm assembly (all models) 01R0591 CRU
Cable, SCSI signal (all models) 32P1871 CRU
Cable, USB (all models) 32P1872 CRU
Cable, operator information card to system board (all models) 32P1870 CRU
Cable, hard disk drive to operator information card (models 11X, 12X, 32P1869 CRU
21X, 22X, 31X, 32X, 3PX, 3WX, 3YX, 3ZX, 51X, 52X, 61X, 62X, 71X,
72X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X, L1X, L2X, M1X, M2X)
Cable, CD signal to system board (models 11X, 12X, 21X, 22X, 31X, 32P1874 CRU
32X, 51X, 52X, 61X, 62X)
Cable, fan 2 drop (all models) 32P1873 FRU
Cable, power 2 drop y cable (models 23x, 24x) 01R0638 FRU
CD-ROM drive, 24X, primary (all models) 06P5263 CRU
CD-ROM drive, 24X, alternate (all models) 19K1523 CRU
CD-ROM drive, 24X, alternate (all models) 33P3231 CRU
Cord, 2.1M jumper (models 11X, 12X, 21X, 22X, 23X, 24X, 31X, 32X, 36L8886 CRU
51X, 52X, 61X, 62X, 71X, 72X, 7RG, 91X, F1X, FRX, G1X, K1X, K2X,
L1X, L2X, M1X, M2X)
118 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Cable, fan 2 drop (all models) 32P1873 FRU
Keyboard CRUs
Keyboard CRU No.
US English 37L2551
French Canadian 37L2552
LA Spanish 37L2553
Arabic 37L2555
Belgium/French 37L2556
Belgium/UK 37L2557
Bulgarian 37L2558
Czech 37L2559
Danish 37L2560
Dutch 37L2561
French 37L2562
German 37L2563
Greek 37L2564
Hebrew 37L2565
Hungarian 37L2566
Korean 02K0901
Iceland 37L2567
Italy 37L2568
Norwegian 37L2569
Polish 37L2570
Portuguese 37L2571
Romanian 37L2572
Russian 37L2573
Serbian/Cyrillic 37L2574
Slavic 37L2575
Spanish 37L2576
Swedish/Finnish 37L2577
Swiss, French/German 37L2578
Turkish 37L2579
Turkish 37L2580
UK English 37L2581
Yugosl/Lat 37L2582
US English-EMEA 37L2583
Chinese/US 37L2585
Thailand 37L2587
French Canadian 37L0913
Power cords
For your safety, IBM provides a power cord with a grounded attachment plug to use
with this IBM product. To avoid electrical shock, always use the power cord and
plug with a properly grounded outlet.
IBM power cords used in the United States and Canada are listed by Underwriter’s
Laboratories (UL) and certified by the Canadian Standards Association (CSA).
For units intended to be operated at 230 volts (U.S. use): Use a UL-listed and
CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT,
three-conductor cord, a maximum of 15 feet in length and a tandem blade,
grounding-type attachment plug rated 15 amperes, 250 volts.
For units intended to be operated at 230 volts (outside the U.S.): Use a cord set
with a grounding-type attachment plug. The cord set should have the appropriate
safety approvals for the country in which the equipment will be installed.
IBM power cords for a specific country or region are usually available only in that
country or region.
120 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
IBM power cord
part number Used on these countries and regions
13F9940 Argentina, Australia, China (PRC), New Zealand, Papua New Guinea,
Paraguay, Uruguay, Western Samoa
13F9979 Afghanistan, Algeria, Andorra, Angola, Austria, Belgium, Benin,
Bulgaria, Burkina Faso, Burundi, Cameroon, Central African Rep.,
Chad, China (Macau S.A.R.), Czech Republic, Egypt, Finland, France,
French Guiana, Germany, Greece, Guinea, Hungary, Iceland,
Indonesia, Iran, Ivory Coast, Jordan, Lebanon, Luxembourg, Malagasy,
Mali, Martinique, Mauritania, Mauritius, Monaco, Morocco,
Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland,
Portugal, Romania, Senegal, Slovakia, Spain, Sudan, Sweden, Syria,
Togo, Tunisia, Turkey, former USSR, Vietnam, former Yugoslavia, Zaire,
Zimbabwe
13F9997 Denmark
14F0015 Bangladesh, Burma, Pakistan, South Africa, Sri Lanka
14F0033 Antigua, Bahrain, Brunei, Channel Islands, China (Hong Kong S.A.R.),
Cyprus, Dubai, Fiji, Ghana, India, Iraq, Ireland, Kenya, Kuwait, Malawi,
Malaysia, Malta, Nepal, Nigeria, Polynesia, Qatar, Sierra Leone,
Singapore, Tanzania, Uganda, United Kingdom, Yemen, Zambia
14F0051 Liechtenstein, Switzerland
14F0069 Chile, Ethiopia, Italy, Libya, Somalia
14F0087 Israel
1838574 Thailand
6952301 Bahamas, Barbados, Bermuda, Bolivia, Brazil, Canada, Cayman
Islands, Colombia, Costa Rica, Dominican Republic, Ecuador, El
Salvador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Korea
(South), Liberia, Mexico, Netherlands Antilles, Nicaragua, Panama,
Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad (West
Indies), United States of America, Venezuela
You can solve many problems without outside assistance by following the
troubleshooting procedures that IBM provides in the online help or in the
publications that are provided with your system and software. The information that
comes with your system also describes the diagnostic tests that you can perform.
Most xSeries and IntelliStation systems, operating systems, and programs come
with information that contains troubleshooting procedures and explanations of error
messages and error codes. If you suspect a software problem, see the information
for the operating system or program.
You can find service information for your IBM products, including supported options,
at http://www.ibm.com/pc/support/.
For more information about Support Line and other IBM services, go to
http://www.ibm.com/services/, or go to http://www.ibm.com/planetwide/ for support
telephone numbers.
In the U.S. and Canada, hardware service and support is available 24 hours a day,
7 days a week. In the U.K., these services are available Monday through Friday,
from 9 a.m. to 6 p.m.
124 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Appendix B. Related service information
Note: The service procedures are designed to help you isolate problems. They are
written with the assumption that you have model-specific training on all computers,
or that are familiar with the computers, functions, terminology, and service
information provided in this manual.
Safety information
The following section contains the safety information that you need to be familiar
with before servicing an IBM computer.
General safety
Follow these rules to ensure general safety:
v Observe good housekeeping in the area of the machines during and after
maintenance.
v When lifting any heavy object:
1. Ensure you can stand safely without slipping.
2. Distribute the weight of the object equally between your feet.
3. Use a slow lifting force. Never move suddenly or twist when you attempt to
lift.
4. Lift by standing or by pushing up with your leg muscles; this action removes
the strain from the muscles in your back. Do not attempt to lift any objects
that weigh more than 16 kg (35 lb) or objects that you think are too heavy for
you.
v Do not perform any action that causes hazards to the customer, or that makes
the equipment unsafe.
v Before you start the machine, ensure that other service representatives and the
customer’s personnel are not in a hazardous position.
v Place removed covers and other parts in a safe place, away from all personnel,
while you are servicing the machine.
v Keep your tool case away from walk areas so that other people will not trip over
it.
v Do not wear loose clothing that can be trapped in the moving parts of a machine.
Ensure that your sleeves are fastened or rolled up above your elbows. If your
hair is long, fasten it.
v Insert the ends of your necktie or scarf inside clothing or fasten it with a
nonconductive clip, approximately 8 centimeters (3 inches) from the end.
v Do not wear jewelry, chains, metal-frame eyeglasses, or metal fasteners for your
clothing.
Remember: Metal objects are good electrical conductors.
v Wear safety glasses when you are: hammering, drilling soldering, cutting wire,
attaching springs, using solvents, or working in any other conditions that might be
hazardous to your eyes.
v After service, reinstall all safety shields, guards, labels, and ground wires.
Replace any safety device that is worn or defective.
v Reinstall all covers correctly before returning the machine to the customer.
CAUTION:
Electrical current from power, telephone, and communication cables can be
hazardous. To avoid personal injury or equipment damage, disconnect the
attached power cords, telecommunication systems, networks, and modems
before you open the server covers, unless instructed otherwise in the
installation and configuration procedures.
Important: Use only approved tools and test equipment. Some hand tools have
handles covered with a soft material that does not insulate you when working with
live electrical currents.
Many customers have, near their equipment, rubber floor mats that contain small
conductive fibers to decrease electrostatic discharges. Do not use this type of mat
to protect yourself from electrical shock.
v Find the room emergency power-off (EPO) switch, disconnecting switch, or
electrical outlet. If an electrical accident occurs, you can then operate the switch
or unplug the power cord quickly.
v Do not work alone under hazardous conditions or near equipment that has
hazardous voltages.
v Disconnect all power before:
– Performing a mechanical inspection
– Working near power supplies
– Removing or installing main units
v Before you start to work on the machine, unplug the power cord. If you cannot
unplug it, ask the customer to power-off the wall box that supplies power to the
machine and to lock the wall box in the off position.
v If you need to work on a machine that has exposed electrical circuits, observe
the following precautions:
– Ensure that another person, familiar with the power-off controls, is near you.
Remember: Another person must be there to switch off the power, if
necessary.
– Use only one hand when working with powered-on electrical equipment; keep
the other hand in your pocket or behind your back.
Remember: There must be a complete circuit to cause electrical shock. By
observing the above rule, you may prevent a current from passing through
your body.
– When using testers, set the controls correctly and use the approved probe
leads and accessories for that tester.
– Stand on suitable rubber mats (obtained locally, if necessary) to insulate you
from grounds such as metal floor strips and machine frames.
Observe the special safety precautions when you work with very high voltages;
these instructions are in the safety sections of maintenance information. Use
extreme care when measuring high voltages.
v Regularly inspect and maintain your electrical hand tools for safe operational
condition.
v Do not use worn or broken tools and testers.
v Never assume that power has been disconnected from a circuit. First, check that
it has been powered-off.
126 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
v Always look carefully for possible hazards in your work area. Examples of these
hazards are moist floors, nongrounded power extension cables, power surges,
and missing safety grounds.
v Do not touch live electrical circuits with the reflective surface of a plastic dental
mirror. The surface is conductive; such touching can cause personal injury and
machine damage.
v Do not service the following parts with the power on when they are removed from
their normal operating places in a machine:
– Power supply units
– Pumps
– Blowers and fans
– Motor generators
and similar units. (This practice ensures correct grounding of the units.)
v If an electrical accident occurs:
– Use caution; do not become a victim yourself.
– Switch off power.
– Send another person to get medical aid.
If any unsafe conditions are present, you must determine how serious the apparent
hazard could be and whether you can continue without first correcting the problem.
The guide consists of a series of steps presented in a checklist. Begin the checks
with the power off, and the power cord disconnected.
Checklist:
1. Check exterior covers for damage (loose, broken, or sharp edges).
2. Turn off the computer. Disconnect the power cord.
3. Check the power cord for:
a. A third-wire ground connector in good condition. Use a meter to measure
third-wire ground continuity for 0.1 ohm or less between the external ground
pin and frame ground.
b. The power cord should be the appropriate type as specified in the parts
listings.
c. Insulation must not be frayed or worn.
4. Remove the cover.
5. Check for any obvious non-IBM alterations. Use good judgment as to the safety
of any non-IBM alterations.
6. Check inside the unit for any obvious unsafe conditions, such as metal filings,
contamination, water or other liquids, or signs of fire or smoke damage.
7. Check for worn, frayed, or pinched cables.
Note: The use of a grounding system is desirable but not required to protect
against ESD damage.
– Attach the ESD ground clip to any frame ground, ground braid, or green-wire
ground.
– Use an ESD common ground or reference point when working on a
double-insulated or battery-operated system. You can use coax or
connector-outside shells on these systems.
– Use the round ground-prong of the ac plug on ac-operated computers.
Grounding requirements
Electrical grounding of the computer is required for operator safety and correct
system function. Proper grounding of the electrical outlet can be verified by a
certified electrician.
128 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Important: All caution and danger statements in this IBM documentation begin with
a number. This number is used to cross reference an English caution or danger
statement with translated versions of the caution or danger statement in this
section.
For example, if a caution statement begins with a number 1, translations for that
caution statement appear in this section under statement 1.
Be sure to read all caution and danger statements before performing any of the
instructions.
Statement 1:
DANGER
Electrical current from power, telephone, and communication cables is
hazardous.
To Connect: To Disconnect:
1. Turn everything OFF. 1. Turn everything OFF.
2. First, attach all cables to devices. 2. First, remove power cords from outlet.
3. Attach signal cables to connectors. 3. Remove signal cables from connectors.
4. Attach power cords to outlet. 4. Remove all cables from devices.
5. Turn device ON.
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
Statement 3:
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or
transmitters) are installed, note the following:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
DANGER
Some laser products contain an embedded Class 3A or Class 3B laser
diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly
with optical instruments, and avoid direct exposure to the beam.
130 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Statement 4:
CAUTION:
Use safe practices when lifting.
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
a service technician.
Statement 10:
CAUTION:
Do not place any object weighing more than 82 kg (180 lb) on top of
rack-mounted devices.
Importante:
132 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Instrução 1
PERIGO
CUIDADO:
Ao substituir a bateria de lítio, utilize apenas uma bateria IBM, Número de Peça 33F8354
ou uma bateria de tipo equivalente, recomendada pelo fabricante. Se o seu sistema possui
um móídulo com uma bateria de lítio, substitua-o apenas pelo mesmo tipo de mídulo, do
mesmo fabricante. A bateria contém lítio e pode explodir se não for utilizada, manuseada e
descartada de maneira correta.
Não:
v Jogue ou coloque na água
v Aqueça a mais de 100°C (212°F)
v Conserte nem desmonte
Para descartar a bateria, entre em contato com a área de atendimento a clientes IBM, pelo
telefone (011) 889-8986, para obter informações sobre como enviar a bateria pelo correio
para a IBM.
Instrução 3
PRECAUCIÓN:
PERIGO
Radiação de laser quando aberto. Não olhe diretamente para o raio a olho nu ou com
instrumentos íticos, e evite exposição direta ao raio.
134 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Instrução 4
Instrução 5
CUIDADO:
2
1
Instrução 8
CUIDADO:
Nunca remova a tampa de uma fonte de alimentação ou de qualquer peça que tenha
esta etiqueta afixada.
Não coloque nenhum objeto com peso superior a 82 kg (180 lbs.) sobre dispositivos
montados em rack.
136 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Appendix B. Related service information 137
138 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Appendix B. Related service information 139
140 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Appendix B. Related service information 141
Important:
Par exemple, si une consigne de type Attention est précédée du chiffre 1, ses
traductions sont également précédées du chiffre 1 dans la présente section.
Notice n° 1
DANGER
142 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Connexion Déconnexion
1. Mettez les unités hors tension. 1. Mettez les unités hors tension.
2. Commencez par brancher tous les 2. Débranchez les cordons d’alimentation
cordons sur les unités. des prises.
3. Branchez les câbles d’interface sur des 3. Débranchez les câbles d’interface des
connecteurs. connecteurs.
4. Branchez les cordons d’alimentation sur 4. Débranchez tous les câbles des unités.
des prises.
5. Mettez les unités sous tension.
Notice n° 2
ATTENTION:
Notice n° 3
ATTENTION:
Si des produits laser sont installés (tels que des unités de CD-ROM ou de DVD, des
périphériques contenant des fibres optiques ou des émetteurs-récepteurs), prenez
connaissance des informations suivantes:
v N’ouvrez pas ces produits pour éviter une exposition directe au rayon laser. Vous
ne pouvez effectuer aucune opération de maintenance à l’intérieur.
v Pour éviter tout risque d’exposition au rayon laser, respectez les consignes de
réglage et d’utilisation des commandes, ainsi que les procédures décrites dans le
présent document.
DANGER
Certains produits laser contiennent une diode laser de classe 3A ou 3B. Prenez
connaissance des informations suivantes:
Notice n° 5
ATTENTION:
2
1
Notice n° 8
ATTENTION:
N’ouvrez jamais le bloc d’alimentation ou tout élément sur lequel e apposée l’étiquette
ci-dessous.
Des tensions et des courants dangereux sont présents à l’intérie de tout composant sur
lequel est apposée cette étiquette. Ces éléments ne peuvent pas être réparés. Si vous
pensez qu’ils peuvent être à l’origine d’un incident, prene contact avec un technicien de
maintenance.
144 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Notice n° 10
ATTENTION:
Ne posez pas d’objet dont le poids dépasse 82 kg sur les unités montées en armoire.
Wichtig:
Hinweis 1
VORSICHT
Aus Sicherheitsgründen:
v Bei Gewitter an diesem Gerät keine Kabel anschließen oder lösen. Ferner keine
Installations-, Wartungs- oder Rekonfigurationsarbeiten durchführen.
v Gerät nur an eine Schutzkontaktsteckdose mit ordnungsgemäß geerdetem Schutzkontakt
anschließen.
v Alle angeschlossenen Geräte ebenfalls an Schutzkontaktsteckdosen mit ordnungsgemäß
geerdetem Schutzkontakt anschließen.
v Signalkabel möglichst einhändig anschließen oder lösen.
v Keine Geräte einschalten, wenn die Gefahr einer Beschädigung durch Feuer, Wasser
oder andere Einflüsse besteht.
v Die Verbindung zu den angeschlossenen Netzkabeln, Telekommunikationssystemen,
Netzwerken und Modems ist vor dem öffnen des Gehäuses zu unterbrechen. Es sei
denn, dies ist in den zugehörigen Installations- und Konfigurationsprozeduren anders
angegeben.
v Nur nach den nachfolgend aufgeführten Anweisungen arbeiten, die für Installation,
Transport oder öffnen von Gehäusen von Personal Computern oder angeschlossenen
Einheiten gelten.
Hinweis 2
ACHTUNG:
Eine verbrauchte Batterie nur durch eine Batterie mit der IBM Teilenummer 33F8354 oder
durch eine vom Hersteller empfohlene Batterie ersetzen. Wenn Ihr System ein Modul mit
einer Lithium-Batterie enthält, ersetzen Sie es immer mit dem selben Modultyp vom selben
Hersteller. Die Batterie enthält Lithium und kann bei unsachgemäßer Verwendung,
Handhabung oder Entsorgung explodieren.
Hinweis 3
ACHTUNG:
VORSICHT
Manche CD-ROM-Laufwerke enthalten eine eingebaute Laserdiode der Klasse 3A oder 3B.
Die nachfolgend aufgeführten Punkte beachten.
Laserstrahlung bei geöffneter Tür. Niemals direkt in den Laserstrahl sehen, nicht direkt mit
optischen Instrumenten betrachten und den Strahlungsbereich meiden.
146 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Hinweis 4
Hinweis 5
ACHTUNG:
2
1
Hinweis 8
ACHTUNG:
Die Abdeckung oder eine Komponente eines Netzteils, die wie nachfolgend aufgeführt
gekennzeichnet ist, darf keinesfalls entfernt werden.
Importante:
Prima di eseguire una qualsiasi istruzione, accertarsi di leggere tutti gli avvisi di
attenzione e di pericolo.
148 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Avviso 1
PERICOLO
ATTENZIONE:
Quando si sostituisce la batteria al litio, utilizzare solo una batteria IBM con numero parte
33F8354 o batterie dello stesso tipo o di tipo equivalente consigliate dal produttore. Se il
sistema di cui si dispone è provvisto di un modulo contenente una batteria al litio, sostituire
tale batteria solo con un tipo di modulo uguale a quello fornito dal produttore. La batteria
contiene litio e può esplodere se utilizzata, maneggiata o smaltita impropriamente.
Evitare di:
v Gettarla o immergerla in acqua
v Riscaldarla ad una temperatura superiore ai 100°C
v Cercare di ripararla o smontarla
Avviso 3
ATTENZIONE:
Quando si installano prodotti laser come, ad esempio, le unità DVD, CD-ROM, a fibre
ottiche o trasmettitori, prestare attenzione a quanto segue:
v Non rimuovere i coperchi. L’apertura dei coperchi di prodotti laser può determinare
l’esposizione a radiazioni laser pericolose. All’interno delle unità non vi sono parti su cui
effettuare l’assistenza tecnica.
v L’utilizzo di controlli, regolazioni o l’esecuzione di procedure non descritti nel presente
manuale possono provocare l’esposizione a radiazioni pericolose.
PERICOLO
Alcuni prodotti laser contengono all’interno un diodo laser di Classe 3A o Classe 3B.
Prestare attenzione a quanto segue:
Aprendo l’unità vengono emesse radiazioni laser. Non fissare il fascio, non guardarlo
direttamente con strumenti ottici ed evitare l’esposizione diretta al fascio.
150 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Avviso 4
Avviso 5
ATTENZIONE:
2
1
Avviso 8
ATTENZIONE:
Non togliere mai il coperchio di un alimentatore o qualsiasi parte su cui è posta la seguente
etichetta.
Tensioni pericolose, corrente e livelli di energia sono presenti all’interno del componente su
cui è posta questa etichetta. All’interno di questi componenti non vi sono parti su cui
effettuare l’assistenza tecnica. Se si sospetta un problema in una di queste parti, rivolgersi
ad un tecnico di manutenzione.
Non poggiare oggetti che pesano più di 82 kg sulla parte superiore delle unità montate in
rack.
152 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Appendix B. Related service information 153
154 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Appendix B. Related service information 155
156 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Importante:
PELIGRO
158 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Declaración 2
PRECAUCIÓN:
Cuando desee sustituir la batería de litio, utilice únicamente el número de pieza 33F8354 de
IBM o cualquier tipo de batería equivalente que recomiende el fabricante. Si el sistema
tiene un mídulo que contiene una batería de litio, sustitúyalo únicamente por el mismo tipo
de mídulo, que ha de estar creado por el mismo fabricante. La batería contiene litio y puede
explotar si el usuario no la utiliza ni la maneja de forma adecuada o si no se desprende de
la misma como corresponde.
Declaración 3
PRECAUCIÓN:
Cuando instale productos láser (como, por ejemplo, CD-ROM, unidades DVD, dispositivos
de fibra íptica o transmisores), tenga en cuenta las advertencias siguientes:
v No retire las cubiertas. Si retira las cubiertas del producto láser, puede quedar expuesto
a radiaciín láser perjudicial. Dentro del dispositivo no existe ninguna pieza que requiera
mantenimiento.
v El uso de controles o ajustes o la realizaciín de procedimientos que no sean los que se
han especificado aquí pueden dar como resultado una exposiciín perjudicial a las
radiaciones.
PELIGRO
Cuando se abre, hay radiaciín láser. No mire fijamente el rayo ni lleve a cabo ningún
examen directamente con instrumentos ípticos; evite la exposiciín directa al rayo.
Declaración 5
PRECAUCIÓN:
2
1
Declaración 8
PRECAUCIÓN:
No retire nunca la cubierta de una fuente de alimentación ni ninguna pieza que tenga
adherida la etiqueta siguiente.
Existen niveles perjudiciales de energía, corriente y voltaje en los componentes que tienen
adherida esta etiqueta. Dentro de estos componentes no existe ninguna pieza que requiera
mantenimiento. Si sospecha que alguna de estas piezas tiene un problema, póngase en
contacto con un técnico de servicio.
160 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Declaración 10
PRECAUCIÓN:
No coloque ningún objeto que pese más de 82 kg (180 libras) encima de los dispositivos
montados en bastidor.
IBM may not offer the products, services, or features discussed in this document in
other countries. Consult your local IBM representative for information on the
products and services currently available in your area. Any reference to an IBM
product, program, or service is not intended to state or imply that only that IBM
product, program, or service may be used. Any functionally equivalent product,
program, or service that does not infringe any IBM intellectual property right may be
used instead. However, it is the user’s responsibility to evaluate and verify the
operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter
described in this document. The furnishing of this document does not give you any
license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.
Any references in this information to non-IBM Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those
Web sites. The materials at those Web sites are not part of the materials for this
IBM product, and use of those Web sites is at your own risk.
IBM may use or distribute any of the information you supply in any way it believes
appropriate without incurring any obligation to you.
Edition notice
© COPYRIGHT INTERNATIONAL BUSINESS MACHINES CORPORATION, 2002,
2003. All rights reserved.
UNIX® is a registered trademark of The Open Group in the United States and other
countries.
Java™ and all Java-based trademarks and logos are trademarks or registered
trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.
Important notes
Processor speeds indicate the internal clock speed of the microprocessor; other
factors also affect application performance.
CD-ROM drive speeds list the variable read rate. Actual speeds vary and are often
less than the maximum possible.
164 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
When referring to processor storage, real and virtual storage, or channel volume,
KB stands for approximately 1000 bytes, MB stands for approximately 1 000 000
bytes, and GB stands for approximately 1 000 000 000 bytes.
Maximum internal hard disk drive capacities assume the replacement of any
standard hard disk drives and population of all hard disk drive bays with the largest
currently supported drives available from IBM.
Some software may differ from its retail version (if available), and may not include
user manuals or all program functionality.
This product may contain a sealed lead acid, nickel cadmium, nickel metal
hydride, lithium, or lithium ion battery. Consult your user manual or service
manual for specific battery information. The battery must be recycled or
disposed of properly. Recycling facilities may not be available in your area.
For information on disposal of batteries, contact your local waste disposal
facility.
In the United States, IBM has established a collection process for reuse, recycling,
or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal
hydride, and battery packs from IBM equipment. For information on proper disposal
of these batteries, contact IBM at 1-800-426-4333. Have the IBM part number listed
on the battery available prior to your call.
Properly shielded and grounded cables and connectors must be used in order to
meet FCC emission limits. IBM is not responsible for any radio or television
interference caused by using other than recommended cables and connectors or by
unauthorized changes or modifications to this equipment. Unauthorized changes or
modifications could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
This product has been tested and found to comply with the limits for Class A
Information Technology Equipment according to CISPR 22/European Standard EN
55022. The limits for Class A equipment were derived for commercial and industrial
environments to provide reasonable protection against interference with licensed
communication equipment.
166 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Taiwanese Class A warning statement
170 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
microprocessor problems 96 power supply
modes, Ethernet 22 installing 66
monitor problems 97 operating requirements 66
mouse problems 95 specifications 3
power-control button 4
power-on password 12
N power-on password override switch 46
network connection problems 38 power-on self-test.
networks 77 See POST
NOS installation priority
with ServerGuide 10 filters 22
without ServerGuide 11 levels 23
notes, important 164 packet mode 22
notices problem solving 25
electronic emission 165 problems
FCC, Class A 165 CD-ROM drive 93
used in this book 2 diskette drive 94
expansion enclosure 94
intermittent 95
O keyboard 95
option problems 99 memory 96
options microprocessor 96
external monitor 97
cabling requirements 75 mouse 95
connecting 72 option 99
installing 41 pointing device 95
order of installation power 99
memory modules 57 serial port 100
software 100
USB port 101
P
password
administrator 12
R
override jumper 12 rack, installing server in 71
power-on 12 recovering the BIOS code 36
PCI REMIND button 34
bus A 49 replacing
bus B 49 battery 69
bus C 49 hot-swap fan 68
PCI-X reset button 4
plug and play, Ethernet 22
pin-number assignments
Ethernet 77 S
plug and play, Ethernet 22 SCSI
pointing device port 74 adapter boot option 49
pointing device problems 95 cable
port external devices 75
Advanced System Management 77 maximum length 75
auxiliary-device 74 IDs 75
connectors 45 SCSI connector
input/output 73 description 75
keyboard 74 location 45
parallel 74 SCSI controller 75
pointing device 74 SCSI error messages 28
serial 76 serial port 76
Universal Serial Bus 76 serial port problems 100
POST ServeRAID Manager
description 27 Configuration wizard
power cords 119 (illus.) 14
power problems 99 ServeRAID programs 9
Index 171
ServerGuide
NOS installation 10
V
video controller 3
setting up multiple servers 11
video port 74
Setup and Installation CD 9
VLAN
using 9
creating 24
ServerGuide error symptoms 28
mode 24
setting
voltage regulator module
password override jumper 12
installing 63
setting up
VRM
multiple servers 11
See voltage regulator module
shutting down the server 7
size 3
SMP 1
software W
problems 100 Web site
software coupon BIOS flash diskette 36
ServerGuide 10 compatible options 41
starting the server 6 IBM server products 1
static electricity 42 SCSI standards 75
static-sensitive devices, handling 42 ServerGuide 10
status lights 5 weight 3
stopping the server 7 working inside server with power on 42
switch World Wide Web 1
power-on password override 46
switch block 46
symmetric multiprocessing 1
system board
connectors
user-installable options 44
LEDs 47
switch block 46
system reliability 41
system-board
connectors
external port 45
internal cable 45
SCSI 45, 75
T
teaming, Ethernet 22
test log, viewing 30
thermal material
heat sink 64
trademarks 164
traffic class expediting 23
turning off the server 7
turning on the server 6
U
United States electronic emission Class A notice 165
United States FCC Class A notice 165
Universal Serial Bus (USB) problems 101
Universal Serial Bus connector 76
Universal Serial Bus port 76
utility
Configuration/Setup 11
172 xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
Printed in USA