AC Line Reactor

AC line reactors are designed to protect sensitive equipment like DC motor drives and AC variable frequency drives from harmful line disturbances. They help prevent equipment failure and extend the life of components. AC line reactors allow for power quality protection, reduction of voltage drops and current surges, improvement of power factor for capacitor input drives, and reduction of harmonic distortion. They can be used with various voltage systems ranging from 240 to 550 volts and ratings from 2 to 100 amps.

Uploaded by

Avismanang
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
167 views1 page

AC Line Reactor

AC line reactors are designed to protect sensitive equipment like DC motor drives and AC variable frequency drives from harmful line disturbances. They help prevent equipment failure and extend the life of components. AC line reactors allow for power quality protection, reduction of voltage drops and current surges, improvement of power factor for capacitor input drives, and reduction of harmonic distortion. They can be used with various voltage systems ranging from 240 to 550 volts and ratings from 2 to 100 amps.

Uploaded by

Avismanang
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

R

AC LINE REACTORS
Function: Features:
Protect your sensitive equipment from harmful line disturbances
with Power House AC line Reactors. AC Line Reactors help prevent
equipment failure and downtime, and can add years to the life of * Gapped iron core inductor-designed
your equipment.
for optimum performance while
Designed to protect DC motor drives, AC Variable frequency drives
and the motors they power. AC line reactors allow line and load power quality protection
providing harmonics
for wide range of applications. compensation.
Benefits: * Precision wound copper coils for
* Protection of motors from damaging voltage drop. maximum protection form short
* Elimination of nuisance tripping of drives or circuit breakers.
* Reduction of motor current surge and power line spike current. circuiting.
* Improvement in true power factor capacitor input drives. * Heavy duty terminal block.
* Cooler, quicker operation.
* Reduction of harmonic distortion. * Amps rating 2 to 100 Amps.
* Longer life of Motor and solid state components. * Can be used with 240, 415, and 550
. Volt System
Application
Input to Inverter/ drive
A1 A2
/ //

DRIVE AC line Reactors protect your sensitive equipment from noise


B1 B2
MOTOR generated by the drive or inverter. They protect the controller
form power surges, spikes and harmonic distortion.

C1 C2

A1 A2
/ //

DRIVE Out put of Inverter/ drive


B1 B2
MOTOR Motors run cooler and quieter with an AC Line Reactor placed between
the inverter and motor. This application also reduces dv/dt and protects
the controller from short circuits and surges.
C1 C2

A1 A2
/ // / //

DRIVE
B1 B2
MOTOR
Multiple controllers on a Single Power Line
C1 C2 Each drive or inverter on a single power line requires its own AC Line
Reactor in order to provide adequate surge protection, prevent crosstalk
A1 A2 and reducing harmonic distortion.
DRIVE
B1 B2
MOTOR
C1 C2

A1 A2 MOTOR Multiple Motors Controlled by a Single Drive


/ //

DRIVE
Multiple motors controlled by a single drive requied only one AC Line
B1 B2
reactor between the controller and motors.
C1 C2 MOTOR

POWER SERVICES 33, Phears Lane, Kolkata -700 073


Ph. (033) 2237-0508, 2236-0575.
Email: [email protected]
Innovative Power Solutions Visit us at www.indiapowerhouse.com

You might also like