0% found this document useful (0 votes)
103 views6 pages

Encoder Job Report

This document summarizes the repair and quality assurance testing of an encoder. It includes details of the customer, part number, repair scope, components replaced, and testing performed including measuring voltages, signal amplitudes, line counts, and functionality tests using equipment like the IK215. On completion, it notes whether the repair was approved and details the work carried out.

Uploaded by

haranahalli
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views6 pages

Encoder Job Report

This document summarizes the repair and quality assurance testing of an encoder. It includes details of the customer, part number, repair scope, components replaced, and testing performed including measuring voltages, signal amplitudes, line counts, and functionality tests using equipment like the IK215. On completion, it notes whether the repair was approved and details the work carried out.

Uploaded by

haranahalli
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 6

Job report of Encoder

SIEMENS

Incoming details:

Repair No Challan No.& Dt

Esskay Job No Software Job No.

Customer Name

MLFB NO Serial No

Description Siemens Warranty

Repair Warranty Yes/No If Yes, old Ref

Outgoing details:

Outgoing Challan No Date

Observation on dismantling & Visual Inspection:

Job received on Snap taken(Y/N)

Oil/Dust Yes / No Mechanical Damage Yes/No

Nature of complaint

Scope Of Work

Remarks If any:

Work to be carried out

Repairability Yes / No

If No, Reason for Irrepairable

Components Replaced
QA OBSERVATION IN PWM9 ONLINE TESTING:

Measure Operating Voltage and Current consumption

Current range(0.9-11ma) Voltage range(4.9-5.0v)

Measure signal Amplitudes

Vpp Measure range(phase shift) A- Frequency measure range


B-

Determine line counts of incremental encoder


Pulse count

QA OBSERVATION ON IK215:

Check Position display ok / Not ok

Position retention after on/off ok / Not ok

check Incremental signal display ok / Not ok

Absolute/Incremental deviation span ok / Not ok

voltage display Measured voltage value

BURNING TEST CONNECTING WITH CONTROL UNIT

Test Start Date and Time :

Test Finish Date and Time :

No.of hours tested :

Cleaning Details:

Oil Dust

Any stickers available Cleaned

On Completion Details :

Repair Carried Out :

Reason for Failure:

Approved By :