Article 59-4. Zoning District Regulations: Div. 4.1. Rules For All Zones Div. 4.4. Development Patterns
Article 59-4. Zoning District Regulations: Div. 4.1. Rules For All Zones Div. 4.4. Development Patterns
DIV. 4.1. RULES FOR ALL ZONES DIV. 4.4. DEVELOPMENT PATTERNS
Sec. 4.1.1. Development Options.............................................................. 4 – 2 Sec. 4.4.1. Development Patterns Allowed by Zone............................. 4 – 34
Sec. 4.1.2. Building Type Descriptions ..................................................... 4 – 3 Sec. 4.4.2. Tandem Housing..................................................................... 4 – 35
Sec. 4.1.3. Building Types Allowed by Zone . ........................................... 4 – 4 Sec. 4.4.3. Cottage Court........................................................................ 4 – 39
Sec. 4.1.4. Measurement and Exceptions ................................................ 4 – 5 Sec. 4.4.4. Garden Court........................................................................ 4 – 43
Sec. 4.1.5. Residential Private Garage Parking Options....................... 4 – 14 Sec. 4.4.5. Corner Store......................................................................... 4 – 47
Sec. 4.1.6. Residential Infill Compatibility............................................ 4 – 16 Sec. 4.4.6. Conservation Subdivision..................................................... 4 – 51
2. Cottage Court
A cottage court is a group of smaller detached houses clustered around a
common open space or courtyard.
3. Garden Court
A garden court is a group of full-size detached houses clustered around a
common open space or courtyard.
4. Corner Store
A corner store is a small retail establishment located on a corner lot at the
edge of a residential neighborhood.
5. Conservation Subdivision
Conservation subdivision is a pattern of residential development that trades
smaller lot sizes (with smaller yards) and additional density in exchange for
protecting a significant amount of common open space.
D2
D2
Residential Zones
Residential Estate - 2 (RE-2)
KEY: = Allowed by Right = Allowed as Part of an Approved Conservation Subdivision = Allowed as Part of an Approved Corner Store Blank cell = Not allowed
A. Site B. Lot
Any lot or group of contiguous lots owned or functionally controlled by the same A site or portion of a subdivision or other parcel of land intended as a unit for the
person or entity, assembled for the purpose of development. purpose, whether immediate or for the future, of transfer of ownership, or pos-
session, or for the purpose of development.
1. Site Area
The area included within the rear, side and front lot lines of the site. Does 1. Lot Area
not include existing or proposed public or private right-of-way, whether The area included within the rear, side and front lot lines. Does not include
dedicated or not dedicated to public use. existing or proposed public or private right-of-way, whether dedicated or not
dedicated to public use.
2. Site Width
Site width is measured between the side lot lines of the site (generally 2. Lot Width
running perpendicular to a street), at the primary street property line along a
a. At the Primary Street Lot Line
straight line or along the chord of the property line.
Measured between the side lot lines (generally running perpendicular to
3. Density a street), at the front lot line along a straight line. Where the property
a. The maximum permitted density is measured by the number of dwelling line is curved, measure along the chord of the lot line.
units allowed per gross acre of land. b. At the Primary Street Setback Line
b. Gross land area is the total area of a site or lot including any existing or Measured between the side lot lines (generally running perpendicular to
proposed streets, highways, or other land required for public use that a street), at the primary street setback line along a straight line. Where
is attributable to the site dedicated by the owner or a predecessor in title. the property line is curved, measure along the chord of the property line.
C. Placement 3. Build-to
1. Building Setbacks a. The area on the lot where a certain percentage of the front building
facade must be located, measured as a minimum and maximum setback
a. Setback Types
range from the edge of the right-of-way.
There are four types of setbacks – primary street setback, side street set-
back, side interior setback and rear setback. Through lots are considered
to have two primary street setbacks.
b. Measurement of Setbacks
i. Primary and side street setbacks are measured from the edge of the
right-of-way.
a
ii. Side interior setbacks are measured from the side property line.
re
A
le
ab
Se
ild
tb
Bu
ac
iii. Rear setbacks are measured from the rear property line or the edge
o
-t
of the right-of-way where there is an alley.
ild
Bu
2. Primary and Side Street Designation
A corner lot must designate at least one primary street. A lot may have more
b. The required percentage specifies the amount of the front building
than one primary street. In determining the primary street, the following
facade that must be located in the build-t0 area, measured based on the
conditions must be considered:
width of the building divided by the width of the lot.
a. The street with the highest street classification;
b. The established orientation of the block;
c. The street abutting the longest face of the block;
d. The street parallel to an alley within the block; and
e. The street that the lot takes its address from.
Se
tb
ack
Bu
ild
ab
le
A
re
a
Bu
ild
in
g
Fa
ca
de
Se
tb
ac
k
4 – 6 Chapter 59: Zoning Code
DR AF T | 13 Oc tober 2010 M o n t g o m e r y C o u n t y, M a r y l a n d
Zoning Advisory Panel Discussion Draft
c. On corner lots, a building facade must be placed within the build-to area b. Building coverage does not include paved areas such as driveways, pe-
for the first 30 feet along the street extending from the block corner. destrian walkways, uncovered porches or patios, decks, swimming pools
d. With the exception of parking areas, all structures and uses customarily or roof overhangs.
allowed on the lot are permitted in the build-to area. 6. Impervious Cover
4. Parking Setbacks
a. The maximum area of the lot that is permitted to be covered by roads,
a. Parking Setback Types driveways, parking areas, concrete pedestrian walkways and patios,
porte cocheres and covered areas such buildings and roofed accessory
There are four types of parking setbacks – primary street parking set-
structures.
back, side street parking setback, side interior parking setback and rear
parking setback. Through lots are considered to have two primary street b. Pools, ponds, fountains, roof overhangs, and areas with gravel placed
parking setbacks. over pervious surfaces that are used only for landscaping or by pedestri-
ans, are considered pervious and are not included in the measurement of
b. Measurement of Parking Setbacks
impervious cover.
i. Primary and side street parking setbacks are measured from the c. For an uncovered deck that has drainage spaces between the deck
edge of the right-of-way. boards and that is located over a pervious surface, 50% of the area of the
ii. Side interior parking setbacks are measured from the side property deck is included in the measurement of impervious cover.
line. d. For interlocking or permeable pavers, 80% of the area of the pavers is
iii. Rear parking setbacks are measured from the rear property line or included in the measurement of impervious cover.
the edge of the right-of-way if there is an alley.
7. Recreation Area
c. Parking Not Allowed
a. Required recreation area must be provided on-site and must generally be
i. On-site surface and structured parking must be located behind the available for use by, or as an amenity for, the occupants of the develop-
parking setback line. ment.
ii. The parking setback line applies to both the ground story and upper b. Required recreation area may be met in one contiguous open area or in
stories of a building. multiple open areas on the site; however, to receive credit the open area
must be at least ten feet in width and length.
5. Building Coverage
c. Required recreation area located at grade cannot be built, parked or
a. The maximum area of the lot that is permitted to be covered by build-
driven upon, except for emergency access and permitted temporary
ings and covered porches and patios, including both principal structures,
events. Required recreation area may be provided above ground through
structured parking and roofed accessory structures.
the use of an outside roof deck, roof top garden, pool area or similar type
of outside common area.
d. Required recreation may be met using required street, side and rear set- b. Mechanical Equipment and Utilities Lines
backs provided they meet the minimum contiguous dimensions estab-
i. Mechanical equipment associated with residential uses, such as
lished in paragraph b. above.
HVAC units and security lighting, may extend into a required rear or
8. Setback Encroachments side setback, provided that such extension is at least five feet from
All buildings and structures must be located at or behind the required the vertical plane of any lot line.
setback lines, except as listed below. Structures below and covered by the ii. Sustainable energy systems may extend into a required rear or side
ground may encroach into any required setback. setback, provided that such extension is at least three feet from the
a. Building Features vertical plane of any lot line.
iii. Rainwater collection or harvesting systems may extend into a re-
i. Porches, stoops, balconies, galleries and awnings as set forth in Sec.
quired rear or side setback, provided that such extension is at least
4.4.F.
three feet from the vertical plane of any lot line.
ii. Chimneys or flues may extend up to four feet, provided that such
iv. Utility lines located underground and minor structures accessory
extension is at least two feet from the vertical plane of any lot line.
to utility lines (such as hydrants, manholes, and transformers and
iii. Building eaves, roof overhangs and light shelves may extend up to
other cabinet structures) may extend into a required rear or side
five feet, provided that such extension is at least two feet from the
setback. Underground utilities may additionally extend into a re-
vertical plane of any lot line.
quired front setback.
iv. Bay windows, entrances and similar features that are less than ten
c. Other Encroachments
feet wide may extend up to four feet, provided that such extension
is at least two feet from the vertical plane of any lot line. i. Fence and walls as set forth in Sec. XX
v. Unenclosed fire escapes or stairways may extend up to four feet, ii. Benches, trash receptacles, public art, water features, bicycle racks,
provided that such extension is at least five feet from the vertical bollards, planters, and other street furniture.
plane of any lot line.
iii. Pedestrian lighting as set forth in Sec. XX
vi. Unenclosed patios, decks or terraces may extend up to four feet
iv. Landscaping, sidewalk, trees, tree grates, and planters as set forth
into a required side setback, or up to eight feet into a required rear
in Sec. XX
setback but, provided that such extension is at least five feet from
the vertical plane of any lot line. v. Driveways as set forth Sec.XX
vii. Cornices, eaves, belt courses, sills, buttresses, or other similar archi- vi. Handicap ramps to the extent necessary to perform their proper
tectural features may project up to 1½ feet. function.
D. Height
1. Building Height c. Where a lot slopes downward from the front property line more then 12
feet along the side of the first 30 feet of the principal building, the height
a. Building height is measured from the average grade to the top of the
of the building past that point must be reduced by at least the drop in
highest point of the roof.
grade in the first 30 feet of the building, and for each successive 30-foot
Pitched Roof Flat Roof increment after that.
Top of Roof 30
Top of Roof
Ac
30
Max Height
Story Story
Max Height
Height
Height
Story
More than
Story 12
Less than
12
Sidewalk
Building Height
3. Height Encroachments d. An accessory structure located on the roof must not be used for any pur-
Any height encroachment not specifically listed is expressly prohibited pose other than a use incidental to the principal use of the building.
except where the Director of Permitting Services determines that the
encroachment is similar to a permitted encroachment as listed below.
a. The maximum height limits of the district do not apply to spires, belfries,
cupolas, domes not intended for human occupancy; monuments, water
tanks/towers or other similar structures which, by design or function,
must exceed the established height limits.
b. The following accessory structures may exceed the established height
limits,except when located within an airport approach area, provided
they do not exceed the maximum building height by more than 12 feet:
i. Chimney, flue or vent stack;
ii. Deck, patio, shade structure;
iii. Flagpole;
iv. Garden, landscaping;
v. Parapet wall, limited to a height of four feet; and
vi. Rainwater collection or harvesting systems.
c. Sustainable energy systems. The following accessory structures may
exceed the established height limits, except when located within an air-
port approach area, provided they do not exceed the maximum building
height by more than 12 feet, do not occupy more than 25% of the roof
area, and are set back at least ten feet from the edge of the roof:
i. Amateur communications tower;
ii. Cooling tower;
iii. Elevator penthouse or bulkhead;
iv. Greenhouse;
v. Mechanical equipment;
vi. Skylights;
vii. Stairway access to roof; and
viii. Tank designed to hold liquids.
4 – 10 Chapter 59: Zoning Code
DR AF T | 13 Oc tober 2010 M o n t g o m e r y C o u n t y, M a r y l a n d
Zoning Advisory Panel Discussion Draft
E. Form
1. Building Orientation
a. An entrance providing both ingress and egress, operable to residents at
all times, is required to meet the street facing entrance requirements.
Additional entrances off another street, pedestrian area or internal park-
ing area are permitted.
b. An angled entrance may be provided at either corner of a building along
Wallll Plate
W Pl
the street to meet the street entrance requirements.
Transparency
Upper Floor
2. Transparency Fin. Floor
Transparency
a. The minimum percentage of windows and doors that must cover a
Upper Floor
ground story facade is measured between 0 and 12 feet above the adja- Fin. Floor
cent sidewalk.
Transparency
Ground Floor
b. The minimum percentage of windows and doors that must cover an
12’
upper story facade is measured from top of the finished floor to the top
of the finished floor above. When there is no floor above, upper story Applicable Transparency
transparency is measured from the top of the finished floor to the top of
the wall plate.
a. Blank wall width means a portion of the exterior facade of the building
that does not include a substantial material change (paint color is not Blank Wall Area Blank Wall Area
F. Building Elements
a. Porch
Lot Line
Setback
i. A porch must be at least six feet deep (not including the steps).
ii. A porch must be contiguous with a width not less than 50% of the
building facade from which it projects.
2 9
iii. A porch may be roofed, but not enclosed. min max
iv. A porch may extend up to nine feet, including the steps, into a
required setback, provided that such extension is at least two feet
from the vertical plane of any lot line. Min 50% 6
min
b. Stoop
Lot Line
Setback
i. A stoop must be no more than six feet deep (not including the
steps) and six feet wide.
ii. A stoop may be roofed, but not enclosed.
iii. A stoop may extend a up to six feet into a required setback, pro-
vided that the landing is at least two feet from the vertical plane of 2
min
5
max
any lot line.
iv. A stoop may not encroach into the public right-of-way. 6
max
6
max
c. Balcony
Lot Line
Setback
vided that such extension is at least two feet from the vertical plane
of any lot line.
ii. A balcony may be roofed, but not enclosed. 2
min
6
max
iii. A balcony may not encroach into the public right-of-way without a
license for the use of public right-of-way.
d. Gallery
Lot Line
Setback
i. A gallery must have a clear depth from the support columns to the
building’s facade of at least eight feet and a clear height above the
sidewalk of at least ten feet.
ii. A gallery must be contiguous and extend over at least
8 50% of the width of the building facade from which it projects.
10
min
min
iii. A gallery may extend into a required street setback.
Min 50%
iv. A galley may not encroach into the public right-of-way without a
license for the use of public right-of-way.
Lot Line
e. Awning
Setback
i. An awning must be a minimum of ten feet clear height above the
sidewalk and must have a minimum depth of six feet.
ii. An awning may extend into a required street setback.
6
min
iii. An awning may not encroach into the public right-of-way without a
license for the use of public right-of-way.
10
min
12 a
m
xm
12 a
B. Detached House and Attached House
x
Se
5
m
i-F
lu
On lots of less than one acre, garage placement must match one of the follow-
sh
ing standards.
1. Semi-Flush
a. Garage doors are oriented towards the street.
b. Garage doors must be positioned between 5 and 20 feet behind the front
wall plane of the house, extending no more than 30% of the width of the
20
house.
Se
tB
ac
k
c. No individual garage door may exceed 12 feet in width and a maximum
of two garage doors are allowed.
2. Set Back
a. Garage doors are oriented towards the street.
b. Garage doors must be positioned at least 20 feet behind the front wall
plane of the house. 15%
3. Side-Loaded
Si
de
-L
3
oa
de
a. Garage doors are oriented perpendicular to the street.
d
b. Any wall of the garage must be located at least three feet behind the
front wall plane of the house.
c. Windows must cover at least 15% of any wall of the garage that faces the
street.
15%
4. Carriage Court
a. Garage doors are oriented perpendicular to the street. Garage is located
Ca
b. Windows must cover at least 15% of any wall of the garage that faces the
street.
4 – 14 Chapter 59: Zoning Code
DR AF T | 13 Oc tober 2010 M o n t g o m e r y C o u n t y, M a r y l a n d
Zoning Advisory Panel Discussion Draft
5. Rear-Loaded
a. Garage is positioned entirely to the rear of the house.
b. Garage doors either can either face the street or be located perpendicu-
lar to street.
Re
ar-
6. Alley-Loaded
Lo
ad
ed
a. Garage is positioned entirely to the rear of the house and is alley-ac-
cessed.
b. Garage doors face the alley.
3
c. The front of the garage must be either located three feet from the edge
20
of the alley right-of-way or be set back at least 20 feet.
A
lle
y-
Loa
de
d
B. Street Setback
1. The building must be located within the range of established front setbacks
on the block.
2. The range of setbacks is measured on the basis of the four lots surrounding
the subject lot (the two closest lots in either direction along the block).
Se
tb
ac
k
Ra
3. The building must be located within the range of setbacks (no closer than
ng
e
the narrowest setback, no further than the deepest setback).
4. Where a setback in these four lots is significantly out of the range of setbacks
along the street, it may be eliminated from the range.
5. Where the calculation of a range of setbacks is not practicable, the building
must meet the district standards.
C. Height
1. Side Setback Plane
Any building is subject to a side setback plane starting at 15 feet in height at
the side property line, and extending upward one foot for every additional
foot into the lot from the side property line. B
B
B
2. Rear Setback Plane A
a. Side-Gabled Roof A B B B
A side-gabled roof structure may extend above the side setback plane 15’ 15’
on each side of the building, for a total length of not more than 30 feet,
A= Not more than 30’
measured from the street setback line along the intersection with the B+B+B+...= Not more than 15’
b. Dormers
Dormers may extend above the side setback plane a total length of not
more than 15 feet on each side of the house, measured along the inter-
section with the setback plane.
15ft
D. Side Wall Length
Articulation is required for side walls on additions or new construction that are
15 feet or taller and located within 15 feet of the side lot line. No wall may ex- 4ft
min
tend for more than 30 feet without a projection or recession of at least four feet 15ft
30ft 10ft
max min
in depth and ten feet in length.
C3
C4
C5
C5
Bu
ild
in
g
B1
Se
tb
ac
ks
C5
C1
C2
Pr
Pr
im
im
B2 y S
et
et
ar
ar
y
re
re
St
St
St
tr
re
ee
de
de
et
t
Si
Si
A. Site AC AR C. Placement AC AR
A1 Area for basic lot alternative (min) 25 acres 5 acres All Buildings/Structures (min)
A1 Area for flexible lot alternative (min) 50 acres 10 acres C1 Primary street setback 50' 35'
40’
40’
30’
30’
5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’ 5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
5’
5’
50' 35'
5’ 5’
A2 Density (max)
10’ 10’
20’ 20’
1u / 25a 1u / 5a
40’
30' 30'
20 or more units 1u / 25a See Sec. 4.4.3 C4 Rear setback, interior 30' 30'
Basic Lot Alternative Coverage (max)
B. Lot C5 All roofed buildings and structures 5% 5%
C6 Impervious cover 5% 10%
Basic Lot Alternative
B1 Lot area (max) 25 acres 5 acres Flexible Lot Alternative Coverage (max)
B2 Lot width at front street line (min) 300' 200' C5 All roofed buildings and structures 10% 10%
B3 Remainder of site placed in no no C6 Impervious cover 20% 20%
conservation or agricultural easement
Flexible Lot Alternative
B1 Lot area (max) 3 acres 3 acres
B2 Lot width at front street line (min) 25' 25'
B3 Remainder of site placed in yes yes
conservation or agricultural easement
D3
D3
D1
E2
Pr
Pr
im
im
et
et
ar
ar
y
y
re
re
St
St
St
St
re
re
de
de
et
et
Si
Si
D. Height AC AR E. Form AC AR
Principal Building (max) Building Orientation
D1 Overall building height 50' 50' E1 Street facing entrance required -- --
40’
40’
30’
30’
5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’ 5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
5’
5’
n/a n/a
5’ 5’
B6
B3
B3
D4
B6
B7 C1
C1
Bu
B1
ild
in
B5
g
Se
B2
tb
ac
Pa
B4
ks
rk
in
Pr
Pr
g
im
im
A St
Se
2 re
et
et
ar
ar
tb
y
y
re
re
ac
St
St
St
ks
re
de
de
et
et
Si
Si
A. Lot AR C. Height AR
A1 Lot area (min) 5 acres All Buildings/Structures (max)
A2 Lot width at front street line (min) 200' C1 Overall building/structure height 50'
40’
40’
30’
30’
5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’ 5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
20’ 20’
B. Placement D. Form
30’ 30’
40’ 40’
B6
B3
B3
B6
D4
B7
B7
C1 C1
Bu
ild
in
g
B1
Se
tb
B5
ac
ks
B2
B4
Pr
Pr
im
im
A St
2 re
et
et
ar
ar
y
y
re
re
St
St
St
re
de
de
et
et
Si
Si
A. Lot AR C. Height AR
A1 Lot area (min) 5 acres All Buildings/Structures (max)
A2 Lot width at front street line (min) 200' C1 Overall building/structure height 50'
40’
40’
30’
30’
5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’ 5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
20’ 20’
B. Placement D. Form
30’ 30’
40’ 40’
C9
C9
C8
C7
ks
ac
tb
Se
C9
C7
e
ur
C4
ct
ru
St
ry
so
es
ks
cc
ac
A
tb
Se
B1
C5
g
in
C3
ld
B3
ui
lB
pa
ci
in
C2
Pr
Pr
Pr
im
im
B2
et
et
ar
ar
y
y
re
re
St
St
St
St
re
re
de
de
et
et
C1
Si
Si
A. Site RE-2 RE-1 RLD-20 RMD-9 RMD-6 C. Placement RE-2 RE-1 RLD-20 RMD-9 RMD-6
A1 Gross Density (max) Principal Building (min)
40’
30’
Less than 20 units 0.50 u/a 1.00 u/a 2.00 u/a 5.00 u/a 8.00 u/a C1 Primary street setback 50' 50' 40' 30' 25'
20’
5’
Pr
10’
20’
20 or more units Conservation subdivision required (see Sec. 4.4.3) C2 Side street setbackim 20' 20' 15' 15' 15'
30’
a
40’
D3
D2 D
1 E2
E1
Pr
Pr
im
im
et
et
ar
ar
y
y
re
re
St
St
St
St
re
re
de
de
et
et
Si
Si
D. Height RE-2 RE-1 RLD-20 RMD-9 RMD-6 E. Form RE-2 RE-1 RLD-20 RMD-9 RMD-6
Principal Building (max) Building Orientation
40’
40’
30’
30’
E3
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
D1 Overall building height 50' 50' 40' 40' 40' E1 Street facing entrance required n/a n/a yes yes yes
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
20’ 20’
E4
40’ 40’
E2
Detached Accessory Structure (max) Gallery, awning no no no no no
D3 Overall structure height 50' 50' 25' 25' 25' Porch, stoop yes yes yes yes yes
D4 Ground Floor Elevation (min) Balcony yes yes yes yes yes
Pr 20' or less from front property line n/a n/a n/a n/a n/a Pr * see Sec. 4.1.4.F for specific building element requirements.
im im
a r More than 20' from front property line n/a n/a n/a n/a n/a ar
y St y S
re t re
et et
C9
C9
C8
C7
ks
ac
tb
Se
C9
C7
e
ur
C4
ct
ru
St
ry
so
es
ks
cc
ac
A
tb
Se
B3
C5
g
in
C3
B1
ld
ui
lB
B2
pa
ci
in
C2
Pr
Pr
im
et
ar
y
re
St
St
re
de
et
C1
Si
D3
D4
Pr
Pr
im
im
et
et
ar
ar
y
y
re
re
D2 D1
St
St
St
St
re
re
E2
de
de
et
et
E1
Si
Si
D. Height RHD-6 RHD-4 RHD-2 E. Form RHD-6 RHD-4 RHD-2
Principal Building (max) Building Orientation
E3
D1 Overall building height 40' 40' 40' E1 Street facing entrance required yes yes yes
P r plate height
D2 Wall 28' 28' 28' Pr
im E2 Allowedi mBuilding Elements *
E4
ar ar
y S Gallery, awningy S t
E2
Detached Accessory
tre Structure (max) no no no
re
D3 Overall structuree t height 25' 25' 25' Porch, stoop et yes yes yes
D4 Ground Floor Elevation (min) Balcony yes yes yes
20' or less from front property line 2' 2' 2' * see Sec. 4.1.4.F for specific building element requirements.
More than 20' from front property line n/a n/a n/a
C9
C9
C8
C7
ks
ac
tb
Se
C9
C7
e
ur
C4
ct
ru
St
ry
so
es
ks
cc
ac
A
tb
Se
B3
C5
g
C3
in
B1
ld
ui
lB
B2
pa
ci
C2
in
Pr
Pr
Pr
im
im
et
et
ar
ar
y
y
re
re
St
St
St
St
re
re
de
de
et
et
C1
Si
Si
A. Site RMD-6 RHD-6 RHD-4 RHD-2 C. Placement RMD-6 RHD-6 RHD-4 RHD-2
A1 Gross Density (max) Principal Building (min)
Less than 20 units 8.00 u/a 8.00 u/a 10.00 u/a 15.00 u/a C1 Primary street setback 25' 20' 10' 5'
P r units
20 or more see Sec. 9.76 u/a 12.20 u/a 18.30 u/a Pr
C2 Side street setback 15' 15' 10' 5'
im im
ar ar
- % MPDUs yrequired (min) 4.4.3 15% 15% 15% C3 Side setback, interior y S 8' 5' 3' 3'
S tre
et C4 Rear setback, interior t r e e 20' 20' 15' 10'
t
B. Lot C4 Rear setback, alley 20' 20' 20' 20'
B1 Lot Area (min) 8,000 sf 8,000 sf 5,500 sf 3,000 sf Detached Accessory Structure (min)
C5 Primary street setback, behind principal bldg. 5' 5' 4' 3'
Lot Width (min)
C6 Side street setback 15' 15' 10' 5'
B2 At front building line 80' 65' 55' 35'
C7 Side setback, interior 5' 5' 3' 3'
B3 At front street line 25' 25' 25' 25'
C8 Rear setback, interior 5' 5' 5' 5'
C8 Rear setback, alley 3' or 20' 3' or 20' 3' or 20' 3' or 20'
Coverage (max)
C9 All roofed buildings and structures 40% 45% 60% 70%
C10 Impervious cover ? ? ? ?
D3
D4
Pr
Pr
im
im
et
et
ar
ar
y
y
re
re
D2 D1
St
St
St
St
E2
re
re
de
de
et
et
E1
Si
Si
D. Height RMD-6 RHD-6 RHD-4 RHD-2 E. Form RMD-6 RHD-6 RHD-4 RHD-2
Principal Building (max) Building Orientation
D1 Overall building height 40' 40' 40' 40' E1 Street facing entrance required yes yes yes yes
P r height
D2 Wall plate 28' 28' 28' 28' Pr
im i m Elements *
E2 Allowed Building
ar ar
Detached Accessoryy S Structure (max) Gallery, awning y S no no no no
tre tre
et
D3 Overall structure height 25' 25' 25' 25' Porch, stoop et yes yes yes yes
D4 Ground Floor Elevation (min) Balcony yes yes yes yes
20' or less from front property line n/a 2' 2' 2' * see Sec. 4.1.4.F for specific building element requirements.
More than 20' from front property line n/a n/a n/a n/a
ac 0
tb C1
ks
C9
Se
g
in
C9
rk
A
Pa
2
C7
C4
C3
B1
C5
Bu
C1
ild
1
in
A
A
3
g
2
Se
B2
tb
ac
ks
C1
Pr
Pr
1
im
im
100%
ar
ar
C2
C1
y
y
St
St
re
re
et
et
et
et
A
C6
3
re
re
St
St
de
de
Setback Min % Build-To Buildable Area Setback
Si
Si
100%
40’
30’
30’
Less than 20 units 8.00 u/a 10.00 u/a 15.00 u/a C1 Primary street setback 15' 10' 5'
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
20 or more units 9.76 u/a 12.20 u/a 18.30 u/a C2 Side street setback 10' 5' 5'
20’ 20’
30’ 30’
40’ 40’
- % MPDUs required (min) 15% 15% 15% C3 Side or rear setback, interior 0' or 5' 0' or 5' 0' or 5'
Project Site (min) C4 Rear setback, alley 3' or 20' 3' or 20' 3' or 20'
A2 Site area 4,800 sf 4,000 sf 3,600 sf Build-to
A3 Site width at front street line 60' 50' 45' C5 Primary street build-to (min/max) 15' to 20' 10' to 15' 5' to 15'
C6 Building width in primary build-to (min) 70% 75% 80%
B. Lot Parking (min)
B1 Lot area (min) 2,000 sf 1,600 sf 1,400 sf C7 Primary street setback 30' 30' 30'
B2 Lot width at front street line (min) 24' 20' 18' C8 Side street setback 10' 5' 5'
C9 Side or rear setback, interior 0' or 5' 0' or 5' 0' or 5'
C10 Rear setback, alley 0' 0' 0'
Coverage (max)
C11 All roofed buildings and structures 75% 75% 75%
C12 Impervious cover ? ? ?
E4
D3
D2
E7
Pr
Pr
im
im
100%
E8
ar
ar
E6
y
y
St
St
D1
re
re
et
et
et
et
E3
re
re
E5
E2
St
St
de
de
E1
Setback Min % Build-To Buildable Area Setback
Si
Si
100%
40’
30’
30’
D1 Overall building height 40' 40' 40' E1 Street facing entrance required yes yes yes
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
2
C1
ks
C1
ac
tb
1
Se
g
in
rk
Pa
C1
1
ks
ac
tb
C4
Se
C7
C9
g
in
ild
C3
Bu
B1
C5
Pr
Pr
im
im
100%
ar
ar
y
C2
St
St
re
re
C1
et
et
et
et
re
re
Si C8
St
St
C6
B2
de
de
Setback Min % Build-To Buildable Area Setback Si
100%
A. Site RHD-4 RHD-2 C. Placement RHD-4 RHD-2
A1 Gross Density (max) All Buildings/Structures (min)
Setback Min % Build-To
Less than 20 units Buildable Area Setback
10.00 u/a 15.00 u/a C1 Primary street setback 10' 5'
40’
40’
20 or more units 12.20 u/a 18.30 u/a C2 Side street setback 5' 5'
30’
30’
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
- % MPDUs required (min) 15% 15% C3 Side or rear, interior 0' or 5' 0' or 5'
20’ 20’
30’ 30’
40’ 40’
D2
E6
E3
E6
E5 E5
D3 E4 E4
Pr
Pr
im
im
100%
ar
ar
E1
y
y
St
St
E7
re
re
D1
et
et
E2
et
et
re
re
E2
St
St
de
de
Si
Si
Setback Min % Build-To Buildable Area Setback
100%
D. Height RHD-4 RHD-2 E. Form RHD-4 RHD-2
All Buildings/Structures (max) Building Orientation
Setback D1%Overall
Min Build-Tobuilding Buildable
height Area Setback40' 40' E1 Street facing entrance required yes yes
40’
40’
30’
30’
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
5’
5’
5’ 5’
10’ 10’
20’ 20’
D2 Overall structure height 25' 25' E2 Overall structure length (max) 140' 144'
30’ 30’
40’ 40’
A
1
C1
B7
B7
Pa ldin
rk
in
g
Bu
Se
i
tb
ac
g
A
ks
B3
Se
2
B4
tb
ac
B9
ks
B6
B1
Pr
Pr
im
im
ar
ar
y
y
B5
St
St
re
re
et
et
et
et
re
re
B2
St
St
de
de
Si
Si
A. Lot RE-1, -2 RLD-20 RMD-9, -6 RHD-6, -4, -2 C. Height RE-1, -2 RLD-20 RMD-9, -6 RHD-6, -4, -2
A1 Lot area (min) 40,000 sf 20,000 sf 20,000 sf 20,000 sf All Buildings/Structures (max)
A2 Lot width at front street line (min) 125' 100' 100' 100' C1 Overall building/structure height 40' 40' 40' 40'
40’
40’
30’
30’
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
20’ 20’
3
All Buildings/Structures (min) D1 Transparency (min)
B1 Primary street setback 50' 40' 30' 30' Street facade 20' or less from property line n/a n/a n/a n/a
B2 Side street setback 20' 15' 15' 15' Street facade more than 20' front property line n/a n/a n/a n/a
B3 Side setback, interior 17' 12' 8' 8'
D2 Blank wall area (max)
B4 Rear setback 35' 30' 30' 30'
20' or less from front property line n/a n/a n/a n/a
Parking (min) More than 20' from front property line n/a n/a n/a n/a
B5 Primary street setback 30' 30' 30' 30'
D3 Allowed Building Elements *
B6 Side street setback 10' 10' 10' 10'
Gallery, awning yes yes yes yes
B7 Side or rear setback, interior 0' or 5' 0' or 5' 0' or 5' 0' or 5'
Porch, stoop yes yes yes yes
B8 Rear setback, alley 0 0 0' 0'
Balcony yes yes yes yes
Coverage (max)
* see Sec. 4.1.4.F for specific building element requirements.
B9 All roofed buildings and structures 30% 40% 50% 60%
B10 Impervious cover ? ? ? ?
A
1
B7
B7
Pa
rk
in
g
Se
C1
tb
ac
C1
A
ks
B3
B9
2
B4
B9
Bu
ild
in
g
B6
B1
Se
Pr
Pr
tb
im
im
ac
ar
ar
ks
y
y
B5
St
St
re
re
et
et
et
et
re
re
B2
St
St
de
de
Si
Si
A. Lot Dimensions RE-1, -2 RLD-20 RMD-9, -6 RHD-6, -4, -2 C. Height RE-1, -2 RLD-20 RMD-9, -6 RHD-6, -4, -2
A1 Lot area (min) 40,000 sf 20,000 sf 10,000 sf 10,000 sf All Buildings/Structures (max)
A2 Lot width at front street line (min) 125' 100' 100' 100' C1 Overall building/structure height 40' 40' 40' 40'
40’
40’
30’
30’
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
20’ 20’
Residential Zones
Residential Estate - 2 (RE-2)
2. Locational Requirements
A tandem housing project must be located:
a. Within ½-mile of an existing or proposed Metrorail or Light Rail Station;
or
b. Within ½-mile of an existing or proposed MARC station or a dedicated,
fixed-route busway station; or
c. Within ¼-mile of a stop on a bus line with service from 6 AM to 8 PM
where service intervals are no longer than 15 minutes during peak com-
mute hours.
3. Spacing Requirements
a. A tandem housing project must be separated by:
i. At least two lots without another tandem housing, cottage court or
garden court development pattern; or
ii. A street.
b. A tandem housing project cannot back up to another tandem housing,
cottage court or garden court development pattern on the same block.
c. Project sites that do not meet the spacing requirements may be ap-
proved through full site plan review (including public hearing).
Bu
ild
in
g
Se
tb
ac
ks
Tandem Housing: Dimensional Standards
4
D
D
3
6
D
ks
5
ac
D
tb
C1
Se
g
in
6
ild
D
D
3
Bu
C3
Pr Pr
1
im im
D
ar ar
y S y S
tre tre
C2
et et
et
et
re
re
St
St
de
de
Si
Si
B. Site RMD-9 RMD-6 RHD-6 RHD-4 D. Placement RMD-9 RMD-6 RHD-6 RHD-4
B1 Allowed Building Types (max %) All Buildings/Structures (min)
40’
40’
30’
30’
Detached house 100% 100% 100% 100% D1 Primary street setback 25' 20' 20' 10'
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
Attached house n/a 100% 100% 100% D2 Side street setback 15' 15' 15' 10'
20’ 20’
30’ 30’
40’ 40’
E3
Pr E2 E1 Pr
im
im
F1
ar ar
F2
y S y S
t re tre
et et
et
et
re
re
St
St
de
de
Si
Si
E. Height RMD-9 RMD-6 RHD-6 RHD-4 F. Form RMD-9 RMD-6 RHD-6 RHD-4 RHD-2
All Buildings/Structures (max) Street Orientation
E3
40’
40’
30’
E1 Overall building height 40' 40' 40' 40' F1 Primary street facing entrance required
30’
20’
5’ 10’ 15’ 20’ 30’ 40’ 40’ 30’ 20’ 15’ 10’ 5’
20’
10’
5’
10’
5’
5’
5’
10’
E4
10’
E2 Wall plate height 28' 28' 28' 28' for end unit yes yes yes yes yes
20’
20’
30’
30’
40’
E2
40’
G. Compatibility
All building types are subject to the standards of Sec. 4.1.6. Residential Infill
Compatibility.
H. Connections
1. Sidewalks adjacent to the project site must be constructed to meet ADA
requirements.
2. Where desired by the transit system provider, the developer must dedicate
an easement for transit access abutting the project site, and construct a
provider-approved shelter for weather protection.
I. Access
1. ADA access to all dwelling units from the adjacent public sidewalk must be
provided.
2. Internal handicapped access to at least one of the dwelling units must be
provided.
J. Environmental Sustainability
1. Each dwelling unit must meet or exceed the US Green Building Council (US-
GBC) LEED silver rating, as determined by a LEED-certified staff member or
through registration with the USGBC.
2. Water-efficient (low flow) fixtures, including those used in irrigation, must be
used.
3. Energy efficient appliances that meet or exceed Energy Star requirements
must be installed in all dwelling units.
4. Street trees must be installed adjacent to the project site, where feasible.
5. On-site tree planting at a rate of one tree per dwelling unit is required.
2. Locational Requirements
Each cottage court project must be located:
a. Within ½-mile of an existing or proposed Metrorail or Light Rail Station; or
b. Within ½-mile of an existing or proposed MARC station or a dedicated,
fixed-route busway station; or
c. Within ¼-mile of a stop on a bus line with service from 6 AM to 8 PM
where service intervals are no longer than 15 minutes during peak com-
mute hours.
3. Spacing Requirements
a. Each project site must be separated by:
i. At least two lots without another cottage court, tandem housing or
garden court development pattern; or
ii. A street.
b. No cottage court may back up to another cottage court, tandem housing
or garden court development pattern on the same block.
c. Project sites that do not meet the spacing requirements may be approved
through full site plan review (including public hearing).
Bu
ild
in
g
Se
tb
ac
ks
Cottage Court: Dimensional Standards
D6
D4
D3
D7
C1
D6
D8
D6
1
D1
D5
D3
D1
D6
C3
Bu
ild
in
g
C2
Se
tb
ac
ac
ks
ks
Pr
Pr
im
im
ar
ar
y
y
St
St
et
et
re
re
re
re
et
et
St
St
de
de
Si
Si
B. Site RMD-9 RMD-6 RHD-6 RHD-4 RHD-2 D. Placement RMD-9 RMD-6 RHD-6 RHD-4 RHD-2
B1 Allowed Building Types (max %) All Buildings/Structures (min)
40’
40’
30’
30’
Detached house 100% 100% 100% 100% 100% D1 Primary street setback 25' 20' 20' 10' 5'
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
F1
E1 E2
F2
Bu
ild
in
F1
g
E4
Se
tb
ba
ac
ck
ks
s
Pr
Pr
im
im
ar
ar
y
y
St
St
et
re
et
re
re
et
re
et
St
St
de
de
Si
Si
E. Height RMD-9 RMD-6 RHD-6 RHD-4 RHD-2 F. Form RMD-9 RMD-6 RHD-6 RHD-4 RHD-2
Principal Building (max) Street Orientation
E3
40’
40’
30’
E1 Overall building height 25' 25' 25' 25' 25' F1 Street facing entrance required for each end
30’
20’
5’ 10’ 15’ 20’ 30’ 40’ 40’ 30’ 20’ 15’ 10’ 5’
20’
10’
5’
10’
5’
5’
5’
10’
E4
10’
E2 Wall plate height 15' 15' 15' 15' 15' unit yes yes yes yes yes
20’
20’
30’
30’
40’
E2
40’
G. Residential Infill Compatibility 7. Shared recycling and composting facilities are required for the project.
All building types are subject to the standards of Sec. 4.1.6. Residential Infill
Compatibility.
H. Connections
1. Sidewalks adjacent to the project site must be constructed to meet ADA
requirements.
2. Each project must provide a shared car or free resident transit passes.
3. Where desired by the transit system provider, the developer must dedicate
an easement for transit access abutting the project site, and construct a
provider-approved shelter for weather protection.
I. Access
1. ADA access to all dwellings units from the adjacent public sidewalk must be
provided.
2. Internal handicapped access to a minimum of 20% of the dwellings units, or
at least one dwelling in all cases, must be provided.
K. Environmental Sustainability
1. Each new dwelling unit must meet or exceed the US Green Building Council
(USGBC) LEED silver rating, as determined by a LEED-certified staff member
or through registration with the USGBC.
2. Water-efficient (low flow) fixtures, including those used in irrigation, must be
used.
3. Energy efficient appliances that meet or exceed Energy Star requirements
must be installed in all new dwelling units.
4. Any existing structure on the project site designated as a historic landmark
must be retained at its original location.
5. Street trees must be installed adjacent to the project site, where feasible.
6. On-site tree planting at a rate of one tree per dwelling unit is required.
2. Locational Requirements
Each garden court project must be located:
a. Within ½-mile of an existing or proposed Metrorail or Light Rail Station;
or
b. Within ½-mile of an existing or proposed MARC station or a dedicated,
fixed-route busway station; or
c. Within ¼-mile of a stop on a bus line with service from 6 AM to 8 PM NOTE: After three ZAP meetings
where service intervals are no longer than 15 minutes during peak com- commenting on the discussion draft and
analysis by planning staff and the
mute hours.
planning board chair, the planning
3. Spacing Requirements director has directed the zoning team to
pull the section on development patterns
a. Each project site must be separated by: (Div. 4.4) out of the draft.
i. At least two lots without another garden court, cottage court or Posted: December 6, 2010
D
3
4
D
D
6
D
6
D
D
5
7
D
C1
8
D
D
6
1
D
D
6
D
C3
C2
3
Pr
Pr
im
im
ar
ar
y
y
St
St
et
et
re
re
re
re
et
et
St
St
de
de
Si
Si
B. Site RMD-9 RMD-6 RHD-6 RHD-4 RHD-2 D. Placement RMD-9 RMD-6 RHD-6 RHD-4 RHD-2
B1 Allowed Building Types (max %) All Buildings/Structures (min)
40’
40’
30’
30’
Detached house 100% 100% 100% 100% 100% D1 Primary street setback 25' 20' 20' 10' 5'
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
Attached house n/a 80% 80% 100% 100% D2 Side street setback 15' 15' 15' 10' 5'
20’ 20’
30’ 30’
40’ 40’
Townhouse building n/a n/a 50% 100% 100% D3 Side setback, interior 5' 5' 5' 3' 3'
Apartment building n/a n/a n/a 100% 100% D4 Rear setback, interior 10' 5' 5' 3' 3'
D4 Rear setback, alley 3' or 20' 3' or 20' 3' or 20' 3' or 20' 3' or 20'
C. Lot D5 Building/structure separation 10' 10' 10' 10' 10'
C1 Lot area (min) 27,000 sf 18,000 sf 18,000 sf 12,000 sf 8,000 sf Coverage (max)
C2 Lot width (min) 180' 150' 150' 120' 100' D6 All roofed buildings and structures 40% 40% 40% 40% 45%
C3 Lot depth (min) 150' 120' 120' 100' 80' Internal Courtyard (min)
C4 Dwelling units per min lot area (max) 5 5 5 5 5 D7 Width 40' 30' 30' 30' 30'
C5 Additional lot area per unit (min) 5,400 sf 3,600 sf 3,600 sf 2,400 sf 1,600 sf D8 Area 2,000 sf 1,500 sf 1,500 sf 1,200 sf 1,200 sf
C6 Dwelling units per project (max) 8 10 10 12 12 D9 Additional area per unit 4,00 sf 300 sf 300 sf 240 sf 240 sf
D10 Orientation All internal units must front on to courtyard
NOTE: After three ZAP meetings
commenting on the discussion draft and Parking (min)
analysis by planning staff and the D11 Primary street setback 20' 20' 20' 20' 20'
D12 Side street setback 20' 20' 20' 20' 20'
planning board chair, the planning
D13 Side or rear setback, interior 5' 5' 5' 5' 5'
director has directed the zoning team to D14 Rear setback, alley 0' 0' 0' 0' 0'
pull the section on development patterns
4 – 44 (Div. 4.4) out of the draft. Chapter 59: Zoning Code
DR AF T | 13 Oc tober 2010 M o n t g o m e r y C o u n t y, M a r y l a n d
Posted: December 6, 2010
Zoning Advisory Panel Discussion Draft
F1
F2
E1 E2
F1
E4
Pr
Pr
im
im
ar
ar
y
y
St
St
et
re
et
re
re
et
re
et
St
St
de
de
Si
Si
E. Height RMD-9 RMD-6 RHD-6 RHD-4 RHD-2 F. Form RMD-9 RMD-6 RHD-6 RHD-4 RHD-2
Principal Building (max) Street Orientation
E3
40’
40’
30’
E1 Overall building height 40' 40' 40' 40' 40' F1 Street facing entrance required for each end unit yes yes yes yes yes
30’
20’
5’ 10’ 15’ 20’ 30’ 40’ 40’ 30’ 20’ 15’ 10’ 5’
20’
10’
5’
10’
5’
5’
5’
10’
E4
10’
E2
40’
G. Residential Infill Compatibility L. Shared recycling and composting facilities are required for the project.
All building types are subject to the standards of Sec. 4.1.6. Residential Infill
Compatibility.
H. Connections
1. Sidewalks adjacent to the project site must be constructed to meet ADA
requirements.
2. Each project must provide a shared car or free resident transit passes.
3. Where desired by the transit system provider, the developer must dedicate
an easement for transit access abutting the project site, and construct a
provider-approved shelter for weather protection.
I. Access
1. ADA access to all dwellings units from the adjacent public sidewalk must be
provided.
2. Internal handicapped access to a minimum of 20% of the dwellings units, or
at least one dwelling in all cases, must be provided.
K. Environmental Sustainability
1. Each new dwelling unit must meet or exceed the US Green Building Council
(USGBC) LEED silver rating, as determined by a LEED-certified staff member
or through registration with the USGBC.
2. Water-efficient (low flow) fixtures, including those used in irrigation, must be
used.
3. Energy efficient appliances that meet or exceed Energy Star requirements
must be installed in all new dwelling units.
4. Any existing structure on the project site designated as a historic landmark
must be retained at its original location.
5. Street trees must be installed adjacent to the project site, where feasible.
6. On-site tree planting at a rate of one tree per dwelling unit is required.
2. Locational Requirements
Each corner store must be located at an intersection of two roads with a
classification of minor arterial or higher.
3. Spacing Requirement
Each corner store must be located no less than a 1,320 feet from any other
corner store located in a residential zone. NOTE: After three ZAP meetings
commenting on the discussion draft and
analysis by planning staff and the
planning board chair, the planning
director has directed the zoning team to
pull the section on development patterns
(Div. 4.4) out of the draft.
Posted: December 6, 2010
D
11
Pa
11
rk
D
C3
in
g
Se
tb
ac
ks
3
D
D
3
D7
Bu
D5
ild
in
g
C1
Se
tb
ac
ks
9
D
D
D
Pr
Pr
10
C4
13
im
im
ar
ar
y
D
St
St
2
re
re
C2
et
et
et
et
re
re
St
St
D6
de
de
D8
Si
Si
B. Site RE-, RLD-, RMD-, RHD- D. Placement RE-, RLD-, RMD-, RHD-
B1 Allowed Building Types (max %) All Buildings/Structures (min)
40’
40’
30’
30’
Mixed use building only 100% D1 Primary street setback 10'
5’ 10’ 15’ 20’ 30’ 40’ 5’ 10’ 15’ 20’ 30’ 40’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
10’
10’
5’
5’
5’ 5’
10’ 10’
E1
F4
E3 F7
F2
E2 F7 F5
E4
Pr
Pr
im
im
F8
ar
ar
F3
y
St
St
re
re
et
et
et
et
re
re
St
St
de
de
Si
Si
F1
E. Height RE-, RLD-, RMD-, RHD- F. Form RE-, RLD-, RMD-, RHD-
Building (max) Building Orientation
40’
40’
30’
E1 Overall building height 32' F1 Primary entrance required within 25 feet
30’
20’
5’ 10’ 15’ 20’ 30’ 40’ 40’ 30’ 20’ 15’ 10’ 5’
20’
10’
5’
10’
5’
5’
5’
10’
E4
10’
E2
40’
G. Compatibility 2. Each site and new residential dwelling must use water-efficient (low flow)
Any building or structure on the project site is subject to a side and rear setback fixtures, including those used in irrigation.
plane starting at 15 feet in height at the side or rear property line, and extend- 3. Each new residential dwelling must include energy efficient appliances that
ing upward one foot for every additional foot into the lot from the side or rear meet or exceed Energy Star requirements.
property line.
4. Street trees must be installed adjacent to the site, where feasible.
H. Connections 5. On-site tree planting at a rate of one tree per dwelling is required.
1. Sidewalks adjacent to the project site must be constructed to meet ADA 6. Shared recycling and composting facilities are required.
requirements.
L. Good Neighbor Plan
2. A sidewalk not less than ten feet in width is required between the building
A corner store is subject to a good neighbor plan acceptable to a majority of the
and the adjacent street.
property owners within 300 feet of the corner store parcel boundaries. A good
3. Where the sidewalk and adjacent street right-of-way is adequate, a bench neighbor plan must describe commitments to the neighborhood related to the
seating at least four persons must be provided. following:
4. Where desired by the transit system provider, the developer must dedicate 1. Property Upkeep
an easement for transit access abutting the project site, and construct a
Litter cleanup, trash removal, landscaping maintenance, graffiti and
provider-approved shelter for weather protection.
vandalism removal.
5. No more than the minimum required parking spaces may be provided on-
2. Sale of Alcohol
site.
Beer/wine only (no malt liquor)?
6. A minimum of four bicycle parking spaces must be provided on-site.
Hours of operation?
I. Access 3. Community Involvement
1. ADA access to the store and all dwelling units from the adjacent public side- Participation in business association, neighborhood crime watch, and
walk must be provided. neighborhood association meetings (where such organizations exist)
2. Only one vehicle access point is allowed on each street frontage. Distribution of contact number to the community.
K. Environmental Sustainability
1. Each corner store must meet or exceed the US Green Building Council
(USGBC) LEED silver rating, as determined by a LEED-certified county staff
member or through registration with the USGBC.
2. Public Facilities
a. Except in the AR Zone, all conservation subdivisions must have access to
public water and wastewater treatment.
b. Except in the AR Zone, on-site treatment systems are not permitted. NOTE: After three ZAP meetings
commenting on the discussion draft and
3. Spacing Requirements analysis by planning staff and the
None. planning board chair, the planning
director has directed the zoning team to
pull the section on development patterns
(Div. 4.4) out of the draft.
Posted: December 6, 2010
B7
B10
B8
B. Site AR RE-2 RE-1 RLD-20 RMD-9 RMD-6 Site (continued) AR RE-2 RE-1 RLD-20 RMD-9 RMD-6
General Criteria Perimeter Setbacks (min)
B1 Area (min) 20 acres 10 acres 4 acres 3 acres 2 acres 1.5 acres B8 Abutting major street 100' 75' 60' 50' 40' 35'
B2 Density (max) 0.30 u/a 0.70 u/a 1.30 u/a 2.44 u/a 6.10 u/a 9.76 u/a B9 Abutting minor street 100' 50' 50' 40' 30' 25'
B3 % of MPDU's (min) 15% 15% 15% 15% 15% 15% B10 Abutting interior lot line 100' 50' 30' 20' 10' 10'
Conservation Area (min) B11 % of Residential Unit Types (max)
B4 Conservation area required 70% 60% 60% 50% 40% 35% Detached house 100% 100% 100% 100% 100% 100%
B5 % of lots abutting con. area 80% 70% 60% 50% 40% 40% Attached house n/a 30% 30% 50% 50% 50%
B6 Contiguous area 60% 60% 60% 60% 60% 60% Townhouse n/a n/a n/a n/a 30% 50%
B7 Width of con. area 50' 50' 40' 30' 25' 20' Apartment n/a n/a n/a n/a n/a 30%
D
8
8
D
E1
D
3
4
D
D
6
7
D
1
D
D
2
E2
et
et
re
re
Pr
Pr
St
St
im
im
de
de
ar
ar
Si
Si
y
y
St
St
re
re
et
et
C. Lot AR RE-2 RE-1 RLD-20 RMD-9 RMD-6 E. Height AR RE-2 RE-1 RLD-20 RMD-9 RMD-6
C1 Area (min) none none none none none none Principal Building (max)
40’
40’
30’
30’
5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’ 5’ 10’ 15’ 20’ 30’ 40’ 50’ 50’
20’
20’
40’ 30’ 20’ 15’ 10’ 5’ 40’ 30’ 20’ 15’ 10’ 5’
C2 Width (min) none none none none none none E1 Overall building height 50' 40' 40' 40' 40' 40'
10’
10’
5’
5’
5’ 5’
10’ 10’
20’ 20’
H. Quality of Design
Turf grass in conservation areas must be limited to those community open
spaces necessary to provide recreation space; all other areas must be active
farmland, forest conservation area, or landscaped with native materials.
I. Environmental Sustainability
1. Total area not within protective easements may not cover more than 25% of
on-site prime agricultural soils.
2. Design and orient 75% or more of the total building square footage (exclud-
ing existing buildings) such that one axis of each qualifying building is at
least 1.5 times longer than the other, and the longer axis is within 15 degrees
of geographical east-west.
3. Incorporate on-site nonpolluting renewable energy generation, such as
solar, wind, geothermal, with production capacity of at least ten percent of
the project’s annual electrical and thermal energy cost (exclusive of existing
buildings), as established through an accepted building energy performance
simulation tool.
J. Conservation Area
Insert conservation area requirements