0% found this document useful (0 votes)
337 views2 pages

Control Hematologico w3 X-Tra 13-09-10

This document provides hematology control parameters for three levels - low abnormal, normal, and high abnormal. It includes expected ranges for parameters such as WBC count, RBC count, hemoglobin, hematocrit, MCV, MCH, MCHC, platelet count, and differential counts for two hematology analyzers - Sysmex KX-Series and Sysmex pocH-100i. The control is to be used to monitor the performance of the analyzers and ensure results are within expected ranges.

Uploaded by

*Elle
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
337 views2 pages

Control Hematologico w3 X-Tra 13-09-10

This document provides hematology control parameters for three levels - low abnormal, normal, and high abnormal. It includes expected ranges for parameters such as WBC count, RBC count, hemoglobin, hematocrit, MCV, MCH, MCHC, platelet count, and differential counts for two hematology analyzers - Sysmex KX-Series and Sysmex pocH-100i. The control is to be used to monitor the performance of the analyzers and ensure results are within expected ranges.

Uploaded by

*Elle
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

EIGHTCHECK-3WP X-TRA TM

HEMATOLOGY CONTROL
Insight Insight Insight
Expiration Date: 2010-11-03 Data Due Date #1: 30-Aug-10 Data Due Date #2: 02-Oct-10 Data Due Date #3: 03-Nov-10
Lot Number: 02080710 02080711 02080712
Control: Low Abnormal Normal High Abnormal

Parameters Mean Expected Range Mean Expected Range Mean Expected Range

SYSMEX KX-SERIES
3
WBC x10 /µL 3.0 2.5 - 3.4 7.1 6.4 - 7.9 18.2 16.4 - 20.0
RBC x106/µL 2.29 2.09 - 2.49 4.26 4.00 - 4.52 5.21 4.95 - 5.47
HGB g/dL 6.6 6.2 - 7.0 13.3 12.5 - 14.1 17.3 16.4 - 18.2
HCT % 17.4 15.9 - 18.9 34.6 32.2 - 37.0 44.9 41.3 - 48.5
MCV fL 76.0 63.9 - 90.4 81.2 71.3 - 92.5 86.2 75.5 - 98.0
MCH pg 28.8 24.9 - 33.5 31.2 27.7 - 35.2 33.2 30.0 - 36.7
MCHC g/dL 37.9 32.9 - 43.9 38.4 33.8 - 43.8 38.5 33.9 - 44.0
PLT x103/µL 49 33 - 65 206 169 - 243 487 424 - 550
Lymph (W-SCR) % 25.9 22.0 - 29.8 31.6 28.4 - 34.8 35.4 31.9 - 38.9
Mixed (W-MCR) % 9.8 5.4 - 14.2 10.8 8.1 - 13.5 15.9 13.2 - 18.6
Neut (W-LCR) % 64.3 59.2 - 69.4 57.6 54.1 - 61.1 48.7 44.8 - 52.6
Lymph (W-SCC) x103/µL 0.8 0.5 - 1.0 2.3 1.7 - 2.8 6.4 5.7 - 7.2
Mixed (W-MCC) x103/µL 0.3 0.1 - 0.4 0.8 0.6 - 1.0 2.9 2.3 - 3.5
Neut (W-LCC) x103/µL 1.9 1.5 - 2.3 4.1 3.5 - 4.7 8.9 7.8 - 9.9
RDW-CV % 10.2 8.6 - 11.8 9.3 7.7 - 10.9 9.6 7.9 - 11.3
RDW-SD fL 33.0 27.4 - 38.6 33.0 27.7 - 38.3 35.6 30.3 - 40.9
MPV fL 9.1 7.6 - 10.6 9.3 8.3 - 10.3 9.2 8.4 - 10.0
W-SMV fL 63.0 53.6 - 72.5 62.9 56.0 - 69.8 63.2 56.9 - 69.5
W-LMV fL 202.3 186.1 - 218.5 202.6 186.4 - 218.8 203.2 188.0 - 218.4

Please note: Remove vial cap before running QC Product


SYSMEX pocH-100i
WBC x103/µL 2.8 2.4 - 3.2 7.1 6.4 - 7.8 18.2 16.4 - 20.0
RBC x106/µL 2.37 2.16 - 2.58 4.42 4.15 - 4.69 5.34 5.07 - 5.61
HGB g/dL 6.3 6.0 - 6.6 13.0 12.4 - 13.7 17.0 16.3 - 17.7
HCT % 19.3 17.7 - 20.9 38.3 35.6 - 41.0 49.1 45.2 - 53.0
MCV fL 81.4 68.5 - 96.9 86.7 76.0 - 98.6 91.9 80.6 - 104.5
MCH pg 26.6 23.2 - 30.6 29.4 26.4 - 32.9 31.8 29.1 - 34.9
MCHC g/dL 32.6 28.6 - 37.5 33.9 30.1 - 38.3 34.6 30.8 - 39.1
PLT x103/µL 47 31 - 63 203 166 - 240 470 409 - 531
Lymph (W-SCR) % 24.8 21.1 - 28.5 31.2 28.1 - 34.3 35.8 32.2 - 39.4
Mixed (W-MCR) % 9.2 5.1 - 13.3 10.5 7.9 - 13.1 15.3 12.7 - 17.9
Neut (W-LCR) % 66.0 60.7 - 71.3 58.3 54.8 - 61.8 48.9 45.0 - 52.8
Lymph (W-SCC) x103/µL 0.7 0.5 - 0.9 2.2 1.7 - 2.8 6.5 5.7 - 7.3
Mixed (W-MCC) x103/µL 0.3 0.2 - 0.5 0.7 0.5 - 0.9 2.8 2.3 - 3.3
Neut (W-LCC) x103/µL 1.8 1.4 - 2.2 4.2 3.6 - 4.8 8.9 7.8 - 10.0
RDW-CV % 14.2 11.9 - 16.5 13.7 11.4 - 16.0 13.9 11.4 - 16.4
RDW-SD fL 40.8 33.9 - 47.7 41.9 35.2 - 48.6 45.0 38.3 - 51.8
MPV fL 10.1 8.5 - 11.7 9.9 8.8 - 11.0 9.7 8.8 - 10.6
W-SMV fL 64.2 48.2 - 80.3 64.0 49.9 - 78.1 63.8 51.0 - 76.6
W-LMV fL 204.9 184.4 - 225.4 204.7 184.2 - 225.2 204.7 184.2 - 225.2

Refer to package insert for Sysmex recommendations on setting QC targets and limits.

Distributed by: 350165


Sysmex America, Inc Rev 8. 06-Jan-10
Distributed by: Jul-10
EIGHTCHECK-3WP X-TRA TM

HEMATOLOGY CONTROL
Insight Insight Insight
Expiration Date: 2010-11-03 Data Due Date #1: 30-Aug-10 Data Due Date #2: 02-Oct-10 Data Due Date #3: 03-Nov-10
Lot Number: 02080710 02080711 02080712
Control: Low Abnormal Normal High Abnormal

Parameters Mean Expected Range Mean Expected Range Mean Expected Range

SYSMEX K-4500, OPEN MODE


3
WBC x10 /µL 3.2 2.8 - 3.6 7.7 6.9 - 8.5 19.6 17.6 - 21.6
RBC x106/µL 2.31 2.17 - 2.45 4.38 4.18 - 4.58 5.26 5.00 - 5.52
HGB g/dL 6.4 6.1 - 6.7 13.3 12.8 - 13.8 17.1 16.4 - 17.8
HCT % 17.5 16.1 - 18.9 35.5 33.0 - 38.0 45.2 42.0 - 48.4
MCV fL
MCH pg
MCHC g/dL
O 75.8
27.7
36.6
65.8
24.9
32.2
-
-
-
87.0
30.9
41.7
81.1
30.4
37.5
72.1
28.0
33.8
-
-
-
90.8
32.9
41.7
85.9
32.5
37.8
76.1
29.7
33.9
-
-
-
96.8
35.6
42.3
PLT x103/µL
Lymph (W-SCR) %
Mixed (W-MCR) %
P 52
25.5
10.3
35
22.7
5.7
-
-
-
69
28.3
14.9
209
31.1
11.4
180
28.0
8.6
-
-
-
238
34.2
14.3
468
34.2
16.5
417
30.8
13.7
-
-
-
519
37.6
19.3
Neut (W-LCR) %
Lymph (W-SCC) x103/µL
Mixed (W-MCC) x103/µL
E 64.2
0.8
0.3
60.3
0.6
0.0
-
-
-
68.1
1.1
0.7
57.5
2.4
0.9
54.1
1.8
0.6
-
-
-
61.0
3.0
1.1
49.3
6.7
3.2
46.3
5.0
2.6
-
-
-
52.3
8.4
3.9
Neut (W-LCC) x103/µL
RDW-CV %
RDW-SD fL
N 2.1
10.6
24.2
1.7
8.9
20.1
-
-
-
2.4
12.3
28.3
4.4
10.0
25.3
4.0
8.3
21.3
-
-
-
4.9
11.7
29.3
9.7
10.3
28.8
8.9
8.4
24.5
-
-
-
10.4
12.2
33.1
MPV fL 9.1 8.1 - 10.1 9.2 8.5 - 9.9 9.2 8.4 - 10.0
W-SMV fL 57.7 52.5 - 62.9 57.8 52.6 - 63.0 58.7 53.4 - 64.0
W-LMV fL 200.7 184.6 - 216.8 201.0 184.9 - 217.1 202.9 187.7 - 218.1

SYSMEX K-4500, CLOSED MODE


WBC x103/µL 3.2 2.7 - 3.7 7.6 6.6 - 8.5 19.2 16.7 - 21.7

C
RBC x106/µL 2.33 2.19 - 2.47 4.34 4.12 - 4.56 5.21 4.92 - 5.50
HGB g/dL 6.4 6.0 - 6.8 13.2 12.7 - 13.7 16.9 16.1 - 17.7
HCT % 17.7 16.2 - 19.2 35.2 32.6 - 37.8 44.7 41.3 - 48.1

L
MCV fL 75.9 65.7 - 87.5 81.2 71.5 - 91.8 85.8 75.2 - 97.6
MCH pg 27.4 24.4 - 31.0 30.4 27.8 - 33.3 32.5 29.4 - 35.9
MCHC g/dL 36.2 31.4 - 41.8 37.4 33.5 - 42.2 37.9 33.6 - 42.7
PLT x103/µL
Lymph (W-SCR) %
Mixed (W-MCR) %
O 51
25.5
10.3
33
21.7
5.2
-
-
-
69
29.3
15.5
194
31.1
11.4
165
27.1
7.6
-
-
-
223
35.1
15.2
431
34.2
16.5
375
29.8
13.0
-
-
-
487
38.6
20.0
Neut (W-LCR) %
Lymph (W-SCC) x103/µL
Mixed (W-MCC) x103/µL
S 64.2
0.8
0.3
57.8
0.6
0.0
-
-
-
70.6
1.1
0.7
57.5
2.4
0.9
51.8
1.7
0.4
-
-
-
63.3
3.0
1.3
49.3
6.6
3.2
44.4
4.7
2.4
-
-
-
54.2
8.5
3.9
Neut (W-LCC) x103/µL
RDW-CV % E 2.1
10.6
24.2
1.6
8.9
20.1
-
-
-
2.5
12.3
28.3
4.3
10.0
25.3
3.7
8.3
21.3
-
-
-
4.9
11.7
29.3
9.5
10.3
28.8
8.3
8.4
24.5
-
-
-
10.6
12.2
33.1

D
RDW-SD fL
MPV fL 9.1 8.1 - 10.1 9.2 8.5 - 9.9 9.2 8.4 - 10.0
W-SMV fL 57.7 52.5 - 62.9 57.8 52.6 - 63.0 58.7 53.4 - 64.0
W-LMV fL 200.7 184.6 - 216.8 201.0 184.9 - 217.1 202.9 187.7 - 218.1

Refer to package insert for Sysmex recommendations on setting QC targets and limits.

Distributed by: 350165


Sysmex America, Inc. Rev 8. 06-Jan-10
Distributed by: Jul-10