New Wiring - 300va

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 3

Input Neutral

BATTERY –VE CN1 (W1) Input Phase (230VAC)


(W3)
BATT 1 MOSFET BANK NO.1 (W4)
Over Load
Preset LB(LOCAL (W5) (W4)
BATTERY MODE)
D MainHigh&low
(W2)
Cut Preset
R COM (W6)

A SB(STANDARD
BATTERY MODE)
I MOSFET BANK NO.2
CN2

N LED STATUS
D
R
A 12v supply
I OUT PUT
N
Neutral
(1) (A)
(B)
Charging(160v)
(2)
(C)
BATTERY +VE (3) (D) 240v 2.5 MFD/ 440V AC CAPACITOR
LED STATUS
TRANSFORMER

INVERTER SWITCH
680  UPS SWITCH

680 

MAIN LED
680 

INVERTER LED
680 
CHARGING
LED
680 
LOW BATTERY
LED
680 
OVER LOAD
LED

TRANSFORMER DETAILS

Transformer Details Stack 3no 2.5inch


Primary : 24 – 0 – 24 turn 14Swg*2

Secondary: 0 – 300 – 320- 370-540 - 570 turn


23Swg
NOTES:

1) W1 to W6 = .75 Sq .mm wire guage


2) DRAIN = 4sq.mm wire guage
3) BATT +VE(12V) = 6sq.mm wire guage(Red Colour)
4) BATT -VE(12V) = 6sq.mm wire guage(Black Colour)
5) R27(470K) = DECREASE CURRENT WILL INCREASE
6) R27(470K)= INCREASE CURRENT WILL DECREASE
7) R13 (15K+2.2K) = STANDARD BAT. RESTANCE DECREASE THAN LOW BAT LEVAL INCREASE AND CHARGING CUT OFF WILL
INCREASE
8) R14(15K+2.7K)
9) PREASET VR2=FOR OVER LOAD
10) PREASET VR1= FOR MAIN HIGH /LOW CUT OFF