Diffusion Coefficient Full Report Tiqa
Diffusion Coefficient Full Report Tiqa
Diffusion Coefficient Full Report Tiqa
CONTENT PAGE
• Abstract / summary 2
• Introduction 2-3
• Aims / objectives 3
• Theory 3-6
• Apparatus 6
• Result 8-9
• Calculation 10-13
• Discussion 14-15
• Conclusion 15
• Recommendation 16
• References 17
• Appendices 18-20
1
ABSTRACT/SUMMARY
INTRODUCTION
Gaseous diffusivity or gas dispersion apparatus which involves diffusion with bulk
flow is one of the items of laboratory equipment that have been designed to allow
measurement of molecular diffusivities and also to make the students become more familiar
with the basic notions of mass transfer theory. This apparatus is a bench mounted apparatus
for the determination of diffusion coefficients of a vapour in air, which uses the method of
measuring the rate of evaporation of a liquid through a stagnant layer into a flowing air
stream, comprising a precision bore capillary tube, which may be filled from a syringe and
2
the top of which means are provided to pass air (or an inert gas) stream to remove vapour.
The apparatus also comprise an air pump, a travelling microscope with accurate focus
adjustment and mounted for vertical axis movement against a Vernier scale and a
thermostatically controlled water bath, in which to place the capillary tube, capable of
accurate temperature control.[1]
The diffusivity of the vapour of a volatile liquid in air can be conveniently determined
by Winklemann’s method in which liquid is contained in a narrow diameter vertical tube,
maintained at a constant temperature, and an air stream is passed over the top of the tube to
ensure the partial pressure of the vapour is transferred from the surface of the liquid to the air
stream by molecular diffusion. The molecular diffusivity, D, is a kinetic parameter associated
with static and dynamic conditions of a process. All the complexity and unwieldiness of
many calculations is, indeed, connected with the determination of this quantity.[2]
OBJECTIVE
THEORY
The diffusion of vapour A from a volatile liquid into another gas B can be
conveniently studied by confining a small sample of the liquid in a narrow vertical tube and
observing its rate of evaporation into a stream of gas B passed across the top of the tube.
3
Normally, for simple instructional purposes, gas B is air and vapour A is an organic solvent
such as acetone or methyl alcohol.[1]
The relation between the measured molar mass transfer rate (NʹA per unit area), the
partial pressure gradient and the diffusion coefficient, D is deduced based on the following;
4
where is the density of the liquid.
ρL
Thus,
Lo and L cannot be measured accurately but L-Lo can be measured accurately using the
vernier on the microscope
or
where:
t = time(s)
5
or
where:
APPARATUS
PROCEDURE
6
Temperature controller
Capillary tube
7
RESULT
• Temperature = 40˚C
• Lo = 40.0 mm
Time, t (min) Time, t (s) Reading of Liquid level t/(L – Lo) t/(L – Lo)
vernier, L (L – Lo) (min/mm)
(s/mm)
(mm) (mm)
0 0 40.0 0.0 0.00 0.00
10 600 40.4 0.4 25.00 1500.00
20 1200 40.6 0.6 33.33 2000.00
30 1800 40.9 0.9 33.33 2000.00
40 2400 41.1 1.1 36.36 2181.82
50 3000 41.4 1.4 35.71 2142.86
60 3600 41.7 1.7 35.29 2117.65
• Temperature = 50˚C
• Lo = 50.0 mm
Time, t (min) Time, t (s) Reading of Liquid level t/(L – Lo) t/(L – Lo)
vernier, L (L – Lo)
(min/mm) (s/mm)
(mm) (mm)
0 0 41.4 0.0 0.00 0.00
10 600 42.1 0.7 14.29 857.14
20 1200 42.5 1.1 18.18 1090.90
30 1800 43.2 1.8 16.67 1000.00
40 2400 43.7 2.3 17.39 1043.48
50 3000 44.1 2.7 18.52 1111.11
60 3600 44.7 3.3 18.18 1090.91
8
• Graph for temperature at 40˚C
CALCULATIONS
58.08 kg/kmol
9
– Total molar concentration, CT (kmol/ m3)
= 122.4273313
=0.0389 kmol/m³
– Logarithmic mean molecular concentration of vapour, CBm (kmol/ m3)
CB1 = CT
CB1 = 0.0389 kmol / m³
Pa −Pv
CB 2 = CT
Pa
CBm =
(CB1 −CB 2 )
CB1
ln
CB 2
= (0.0389-0.0174)ln0.03890.0174
0.0267 kmol / m³
PV
CA = CT
Pa
= 56101.30.0389
=0.0215 kmol / m³
– Diffusivity, D (m2/s)
10
D=
( ρLCBm )
s ( 2 MCACT )
ρL = 790kg /m³
D= (790 kg/m³)(0.0267kmol/m³)
11
• Calculation for temperature at 50˚C
= 122.4273323
=0.0377 kmol/m³
– Logarithmic mean molecular concentration of vapour, CBm (kmol/ m3)
CB1 = CT
CB1 = 0.0377 kmol / m³
Pa −Pv
CB 2 = CT
Pa
12
CBm =
(CB1 −CB 2 )
CB1
ln
CB 2
= (0.0389-0.0169)ln0.03890.0169
= 0.0259 kmol / m³
PV
CA = CT
Pa
= 56101.30.0377
=0.0208 kmol / m³
– Diffusivity, D (m2/s)
D=
( ρLCBm )
s ( 2 MCACT )
ρL = 790kg /m³
D= (790 kg/m³)(0.0259kmol/m³)
13
DISCUSSION
The objectives of this experiment are to determine the diffusivity of the vapour of
acetone and to study the effect of temperature on the diffusivity which based on the mass
transfer theory of the molecular diffusion in gases.
To archive the objectives of this experiment, the gas dispersion apparatus is used.
This apparatus is combined with vernier scale and microscope which is used to measure and
read the level of meniscus in the capillary tube which contains acetone. The diffusion of the
vapour of acetone (volatile liquid) into another gas can be conveniently studied can by
confining a small sample of the liquid in a narrow vertical tube, and observing its rate of
evaporation into a stream of gas passed across the top of the tube.
The experiment is divided into two parts which differ in terms of temperature. First
part, the experiment is run by using temperature of 40˚C and the diffusivity of the vapour of
acetone obtained is 2.054 x 10-7 m2/s. For the second part, the experiment is repeated by using
temperature of 50˚C and the diffusivity of the vapour of acetone obtained is 8.875 x 10 -7 m2/s.
Based on the result obtained from both part, the graph of t/(L – L o) against (L – Lo) was
plotted. From the graph, it can be observed that the graph plotted for the temperature of 40˚C
is a little bit steeper than the graph plotted for the temperature of 50˚C. Other than that, from
the graph plotted, the value of slope can be obtained easily and the calculation of diffusivity
of the vapour can be proceeding.
From the calculation that has been done, it is shows that the value of diffusivity is
affected by the temperature. The higher the temperature, the diffusivity of the vapour or the
diffusion coefficient of acetone would increase. Diffusion is the movement of molecules from
an area of high concentration to an area of lower concentration and this is increased with
increasing temperature which means when the temperature increase the diffusion will speeds
up.[4] Thus, if the temperature is higher, then probably it would increase the rate of diffusion
by increasing the kinetic activity of the solution. The molecules of the solution would be
moving more vigorously and so naturally the chances of them moving through pores in a
membrane would be much better.[5] Therefore, the molecules spread from high to low
concentration more rapidly.[6] There is much difference in the value of diffusivity obtained
from both temperature which is determine by 6.821 x 10-7 m2/s.
The higher temperature used in this experiment is only 50˚C. As we know, the boiling
point of acetone is 56.5˚C and if the temperature is exceeding the boiling point temperature
the diffusivity will not be feasible. This is caused by the characteristics of the acetone
14
solution which is volatile. An increase in pressure has a significant effect on the relative
volatility of the component in a liquid mixture. Since an increase in the pressure requires an
increases in the temperature, then an increase in temperature also effects the relative
volatility.[7] Therefore, the temperature conducted in this experiment must not exceed the
boiling point of the acetone because it will increase the rate of volatility of acetone. Thus, it
will be harder to read the level of meniscus on the sliding vernier scale since the solution is
volatile rapidly.
The value obtain from the result might be different with the actual because there may
be some error occur during the experiment is done. The common error that always occurs is
the position of the eye during taking the volume at the burette. The eye position should be
straight to the scale and must be parallel to the meniscus. Other than that, the experiment
should be repeated at least 3 times to get the accurate values and this can reduce the mistake
during the experiment is done.
CONCLUSION
As a conclusion:
1. At temperature of 40˚C, the diffusivity of the vapour of acetone is 2.054 x 10-7 m2/s
meanwhile at temperature of 50˚C, the diffusivity of the vapour of acetone obtained is
8.875 x 10-7 m2/s.
2. From the graphs plotted, it can be conclude that flowing air significantly increases the
diffusion coefficient thus increasing the mass transfer.
3. Other than that, it can be concluded that the higher temperature affect the diffusivity
of the vapour. Faster diffusion will take place if the surrounding is warmer. Increase
in temperature means an increase in molecules’ speed (kinetic energy). Therefore, the
molecules move faster and there will be more spontaneous spreading of material
which means that diffusion occurs quicker.[3] Therefore, the higher the temperature,
the higher the diffusivity of the vapour.
15
RECOMMENDATION
1. To evaporate quickly the best way would be to pass air flow over the liquid, if want a
fluid to evaporate slowly would not pass air over.
2. The flow rate of flowing air must be constant throughout this experiment.
3. The level of meniscus must be correctly observed on the microscope and also read on
the vernier scale.
4. Repeat the experiment twice for each set of temperature to get the average reading for
more accurate result.
5. Clean up the apparatus before start the experiment.
6. Make sure the microscope is in good condition before run the experiment.
7. Changes the water bath when want to start a new set of temperature.
8. Always checks the air pump (make sure it functions all the time during the
experiment).
16
REFERNCES
1. CERa/CERb Mass Transfer and Diffusion Coefficients – Issue 10, 1 October 2010 at
http://www.discoverarmfield.co.uk/data/cer/?js=enabled
2. Determining the diffusivity of nitrogen tetroxide, 1 October 2010 at
http://www.springerlink.com/content/k0501550x585x0kn/
3. How does the temperature affect the diffudion rate?, 1 October 2010 at
http://wiki.answers.com/Q/How_does_temperature_affect_diffusion_rate
4. How does temperature affect the rate of diffusion?, 1 October 2010, at
http://www.studyzones.com/questionzone/answer/73267x1565/How-does-
temperature-affect-the-rate-of-diffusion
5. How temperature affects diffusion, 1 October 2010, at http://www.biology-
online.org/biology-forum/about2736.html?hilit=Balloon+cell
6. Does temperature effect diffusion rate, 1 October 2010, at
http://www.reference.com/motif/Science/does-temperature-effect-diffusion-rate
7. Relative volatility, 1 October 2010, at
http://en.citizendium.org/wiki/Relative_volatility
8. Christie John Geankoplis (University of Minnesota), Transport Processes and
Separation Process Principles (Includes Unit Operations) – fourth edition, Pearson
Education International.
17
APPENDICES
18
Figure 1
19