PF40 Step Logic

The document describes the step logic functions of a PowerFlex40 drive. It allows for up to 8 configurable steps that can control frequency, direction, and timing of a motor. Digital and analog inputs can be used with logic, timer, and counter functions to control stepping through the sequence. The functions provide flexibility for applications like speed profiling, indexing, traversing, and parts counting.

Uploaded by

Er. Piush Jindal
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
102 views13 pages

PF40 Step Logic

The document describes the step logic functions of a PowerFlex40 drive. It allows for up to 8 configurable steps that can control frequency, direction, and timing of a motor. Digital and analog inputs can be used with logic, timer, and counter functions to control stepping through the sequence. The functions provide flexibility for applications like speed profiling, indexing, traversing, and parts counting.

Uploaded by

Er. Piush Jindal
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 13

PowerFlex40

Step Logic

May 2003
Logic Functions
• It Step
startsLogic
with a philosophy
• Logical functions
• Digital Input AND, OR, NOR
• Timer Function
• Digital Output(s) used
• Counter Function
• Digital Output(s) used
Step Logic Function
• Up to 8 step available (0 – 7)
• [Stp Logic 0 – 7] parameters A140 – A147
• Uses Preset Frequencies only
• [Preset Freq 0 – 7] parameters (A070 – A077)
• Time Based Steps
• [Stp Logic Time 0 – 7] parameters A150 – A157
• [Speed Reference] P038 setting “Stp Logic”
Step Logic Example

Step 0 Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7

FWD

REV
time
Logic Function
• Digital Inputs
• “Logic In1” & “Logic In2”
• Logic Programming
• Define logic required for machine
• Digital Outputs
• On or Off depending on the state of the logic inputs.
• Can be used with or without Step Logic
Logic Example

Start Step 0 Step 1 Step 2 Step 3

Freq

Logic In1

Logic In2
Timer Function
• Digital Inputs
• “Timer Start”, “Reset Timer”, “Reset Timer & Counter”
• Digital Output(s)
• Set Timer level
• Output changes state when level reached
• Can be used with or without Step Logic
Timer Example
Preset Freq 1 Analog
30 Hz Reference

Start

Relay Out

Digital In1
Preset Freq

Digital In2
Timer Start
20 sec
Counter Function
• Digital Inputs
• “Counter In”, “Reset Counter”, “Reset Timer & Counter”
• Digital Output(s)
• Set Count level
• Output changes state when level reached
• Can be used with or without Step Logic
Counter Example

Output
Freq

Start

Relay Out

Photo eye

Digital In1
Counter In

Digital In2
Reset Counter
Limit
Switch
Step Logic Programming
• 4 digit code defines step actions
• Digit 3
• Defines the action during the current step
• Digit 2
• Defines what step to jump to when Digit 1 logic met
• Digit 1
• Defines the logic required for the “jump”
• Digit 0
• Defines the logic for the “next” step (numeric progression)
Logic Codes
Applications for Step Logic
• Speed profile based on time
• Simple indexing Fwd & Rev with coarse positioning
using presence sensors.
• Traversing Fwd & Rev of carriage with coarse
positioning using presence sensors.
• Parts counter and diverter