06n Rr410305 Refrigeration Air Conditioning
06n Rr410305 Refrigeration Air Conditioning
06n Rr410305 Refrigeration Air Conditioning
www.andhracolleges.com
1. (a) Explain the boot strap air cycle refrigeration system with a schematic and
cycle diagrams.
(b) Derive an expression for the COP of Bell- Coleman cycle.
and 25 deg. C. The gas is dry at the end of compression and there is no under
cooling of liquid. Using the tables, Calculate the theoretical COP of the cycle.
[14]
[8]
[2]
5. (a) What are the characteristics of ideal absorbent and refrigerant mixture in
vapour absorption refrigeration. [8]
www.andhracolleges.com
(b) Explain with a simple sketch the construction of Electrolux refrigeration sys-
tem. [8]
6. In a Steam jet refrigeration system dry saturated steam at 7 bar abs. pressure
is supplied. The flash chamber temperature is 5o C, the condenser temperature is
40o C, make up water is supplied at 20o C. Assuming that quality of motive steam
and flash vapour at the beginning of compression as 93% dry and efficiency of the
nozzle, efficiency of entertainment and the efficiency of the thermo-compressor as
90%, 65%and91% respectively. Determine:
7. (a) Define the term “effective temperature” and explain its importance in air-
conditioning systems. Describe the factors which affect the effective temper-
ature.
[8]
(b) Define the “human comfort” and describe the factors which affect the human
comfort. [8]
Seminar Topics - Scholarships - Admission/Entrance Exam Notifications
1 ofUSA-UK-Australia-Germany-France-NewZealand
2 Universities List
⋆⋆⋆⋆⋆
www.andhracolleges.com
www.andhracolleges.com
Seminar Topics - Scholarships - Admission/Entrance Exam Notifications
2 ofUSA-UK-Australia-Germany-France-NewZealand
2 Universities List
www.andhracolleges.com
1. (a) What is the difference between a refrigerator and a heat pump?
(b) The capacity of a refrigerator is 200 TR when working between - 8o C and
26o C. Determine the mass of ice produced per day from water at 260 C. Also
find the power required to drive the unit. Assume that the cycle operates on
reversed carnot cycle and latent heat of ice is 335 kJ/kg.
2. A simple vapour compression cycle using F-12 is designed to take a load of 10
[12]
tons. The refrigerator and ambient temperatures are 00 C and 300 C respectively.
A minimum temperature of -50 C is required in evaporator and condenser for heat
transfer. Find
[4]
www.andhracolleges.com
4. (a) Differentiate between flooded type and dry expansion type evaporators. [6]
(b) Explain the working of thermostatic expansion valve with the help of a neat
sketch. [10]
5. (a) What are the characteristics of ideal absorbent and refrigerant mixture in
vapour absorption refrigeration. [8]
(b) Explain with a simple sketch the construction of Electrolux refrigeration sys-
tem. [8]
6. (a) What are the limitations of steam jet refrigeration system. [8]
(b) What are the merits of steam jet refrigeration system over other system? [8]
7. (a) A quantity of air having a volume of 300 m3 at 30o C (DBT) and 25o C (WBT)
is heated to 40o C (DBT). Estimate the amount of heat added, final relative
humidity and WBT. The air pressure is 1.01325 bar. [6]
(b) 800m3 /min of re-circulated air at 22o C (DBT) and 10o dew point tempera-
ture is to mixed with 300 m3 /min of fresh air at 30o C (DBT) and 50% RH.
Determine the enthalpy, specific volume, humidity ratio and dew point temp
of the resultant mixture. [10]
Seminar Topics - Scholarships - Admission/Entrance Exam Notifications
1 ofUSA-UK-Australia-Germany-France-NewZealand
2 Universities List
⋆⋆⋆⋆⋆
www.andhracolleges.com
www.andhracolleges.com
Seminar Topics - Scholarships - Admission/Entrance Exam Notifications
2 ofUSA-UK-Australia-Germany-France-NewZealand
2 Universities List
www.andhracolleges.com
1. (a) Explain the importance of Industrial Refrigeration citing specific cases.
(b) Distinguish between vapour absorption and vapour compression system and
what is the distinct advantage of vapour absorption over vapour compression
system. [4]
(c) Explain the working principle of vapour compression refrigeration system with
a neat diagram and also plot the same on a P-h and T-s diagram
2. (a) Derive an expression for COP of vapour compression cycle from t-s chart when
the refrigerant is dry saturated before compression.
[8]
[6]
[4]
www.andhracolleges.com
(iii)Ratio of COP of this cycle to COP of carnot cycle.
[10]
[6]
[10]
[6]
www.andhracolleges.com 1 of 2
Engineering-MBA-MCA-Medical-Pharmacy-B.Ed-Law Colleges Information
www.andhracolleges.com The Complete Information About Colleges in Andhra Pradesh
6. (a) How can you produce the cold with the vortex tube? [6]
(b) What is the principle in steam jet refrigeration. Explain with neat sketch.[10]
www.andhracolleges.com
7. (a) An air water vapor mixture at 1 bar and 26.7o C has a specific humidity of
0.0085. Determine the percentage saturation.
culate
8. (a) A heat pump uses water at 10C as the source of heat and the air supplied to
the room is to be at 350 C. If the actual EPR attained is 70% of the reversed
carnot cycle operating between the same temperatures, determine
i. The actual EPR of the heat pump system
www.andhracolleges.com
ii. The power required to run the compressor if required heat load is 60,000
KJ/hr.
The power required to run the compressor if required heat load is 60,000
KJ/hr. [10]
(b) What are the different constructional features used in heat pump to improve
the overall EPR? [6]
⋆⋆⋆⋆⋆
www.andhracolleges.com
1. (a) Give a brief description of an ideal cycle of air refrigeration.
(b) A carnot refrigerator and a heat pump are supplied with equal amount of
work. The refrigerator operates between -270 C and +270 C and the heat pump
operates between + 450 C and + 270 C. The refrigerator absorbs 4000 kJ/ min
at -270 C. The heat pump absorbs all the heat rejected by the refrigerator and
supplies at 450 C. Compute
2. (a) Describe the use of liquid vapour regenerative heat exchanger in a vapour
compression system [6]
(b) A simple saturation ammonia compression system has a high pressure of 1.35
www.andhracolleges.com
MN/m2 and low pressure of 0.19 MN/m2 . Find per 400,000kJ/h of refrigerat-
ing capacity the power consumption of the compressor and COP of the cycle.
[10]
5. (a) What is the effect of inert gas in three fluid refrigeration system. [4]
(b) What is absorption refrigeration system and how it differs from convention
vapour compression system and explain its working. [8]
(c) What is Carnot COP of absorption refrigeration system. How it is differ from
actual COP. [4]
6. (a) With the help of a sketch of the processes on Mollier chart explain how the
refrigeration is produced in steam jet refrigeration system. [10]
(b) What difference does it make when the steam jet refrigeration system operates
with a barometric condenser instead of a surface condenser? [6]
Seminar Topics - Scholarships - Admission/Entrance Exam Notifications
USA-UK-Australia-Germany-France-NewZealand Universities List
www.andhracolleges.com Engineering-MBA-MCA-Medical-Pharmacy-B.Ed-Law
1 of 2 Colleges Information
www.andhracolleges.com The Complete Information About Colleges in Andhra Pradesh
www.andhracolleges.com
(b) Capacity of the heating coil in kW
(c) By-pass factor of the heating coil if the surface temp of the coil is 22o C [16]
8. (a) Define the following in relation to the conditioned supply air to room ‘Throw’,
‘Drop’ and ‘Spread’. [6]
(b) State the different types of supply air out lots.
(c) Describe the factors governing the selection and location of supply air outlets.
[4]
⋆⋆⋆⋆⋆
www.andhracolleges.com
Seminar Topics - Scholarships - Admission/Entrance Exam Notifications
2 ofUSA-UK-Australia-Germany-France-NewZealand
2 Universities List