MPWD Sor Vol. II Plinth Area Rate
MPWD Sor Vol. II Plinth Area Rate
MPWD Sor Vol. II Plinth Area Rate
2013
SL No
DECRIPTION
OFFICE/COLLEGE/HOSPITAL/SCHOOLS/
AUDITORIUM
1.0(A)
1.1(A)
1.1.1(A)
1.1.2(A)
1.0(B)
1.1(B)
1.1.1(B)
1.1.2(B)
1.2
1.2.1
1.2.2
22000
590
600
1.2.3
280
1.2.4
280
1.2.5
280
1.2.6
2350
1.2.7
1.2.8
1.2.9
1.2.10
1.2.11
1.2.12
530
1190
6690
12200
1590
1860
SL No
DECRIPTION
OFFICE/COLLEGE/HOSPITAL/SCHOOLS/
AUDITORIUM
1.3
1.3.1
1.3.2
1.3.2.1
1.3.2.2
1.3.2.3
1.4
1.4.1
1.4.2
1.5
1.5.1
1.5.2
1.6
1.7
1.8.1
1.8.2
BASEMENT FLOOR
Floor ht.3.30 mtrs with normal waterproofing treatment with
bituminous felt
EXTRA FOR BASEMENT WITH
Mastic asphalt W.P.T
Every 0.3 mt. addl.Height (above 3.30 mt)
19600
(-)1370
2150
2390
565
845
565
2320
94
10190
490
ANNEXURE-I
HOSTELS/RESIDENTIAL
4
30000
26000
590
600
280
280
280
2350
530
1190
6690
12200
1590
1860
HOSTELS/RESIDENTIAL
4
565
845
565
94
10190
490
Sl no
DESCRIPTION
1
3.O
2
SERVICES.
3.1
3.2
3.3
3.4
3.5
3.6
3.6.1
3.6.2
3.6.3
3.6.3.1
3.6.3.2
3.6.3.3
3.6.4
3.6.5
3.6.6
Office &
Hospitals
College
3
4
4%
10%
Hostels
I
7
Types
II
8
5%
15% with
attached
woilets
12%
12%
of
III
9
Quarter
12%
10% with
common %age means %age of building cost of norm
toilets.
5%
5%
5%
5%
5%
5%
5%
12.50%
12.50%
12.50%
12.50%
12.50%
12.50%
12.50%
Note : The above include sevice connection charge and electricfication.
15% of
building
cost of
normal
building
(1.0B)
Schools
15% of
building
cost
4%
1%
4%
0.50%
0.33%
0.25%
0.50%
0.50%
0.33%
0.25%
0.50%
0.50%
0.33%
0.25%
0.50%
0.50%
0.33%
0.25%
0.50%
0.50%
0.50%
0.50%
0.50%
0.50%
0.33%
0.25%
0.50%
1%
0.50%
0.33%
0.25%
0.50%
1%
0.50%
0.33%
0.25%
0.50%
1%
3.6.7
Quality assurance
1%
1%
1%
1%
1%
1%
1%
Types
of
Quarters
IV
10
12%
12%
5%
12.50%
5%
12.50%
0.50%
0.33%
0.25%
0.50%
1%
0.50%
0.33%
0.25%
0.50%
1%
1%
1%
SL no
Type of lift
Capacity/
persons
weight
speed in
M/sec.
Travel
Doors
Control
1
4
4.1
LIFTS
Passanger lifts
4.1.1
Passanger lift
544kg
G+4
power
operated
ACV
VVF
4.1.2
Passanger lift
544 kg
1.5
G+4
power
operated
ACV
VVF
4.1.3
Passanger lift
13
884 kg
G+4
power
operated
ACV
VVF
4.1.4
Passanger lift
13
884 kg
1.5
G+4
power
operated
ACV
VVF
4.1.5
Passanger lift
16
1088 kg
G+4
power
operated
ACV
VVF
4.1.6
Passanger lift
16
1088 kg
1.5
G+4
power
operated
ACV
VVF
4.1.7
Passanger lift
16
1088 kg
2.5
G+4
power
operated
ACV
VVF
4.1.8
Passanger lift
20
1360 kg
0.75
G+4
power
operated
ACV
VVF
4.1.9
Passanger lift
20
1360 kg
1.5
G+4
power
operated
ACV
VVF
4.1.10
Passanger lift
20
1360 kg
2.5
G+4
power
operated
ACV
VVF
0.5
0.5
0.25
G+4
G+4
G+4
4.2
4.2.1
4.2.2
4.2.3
Price
(Rs. In
lacs)
Addl.
Price for each
additional floor (Rs.
In lacs)
10
32
42
42
44.5
40
2.6
45.8
2.6
134
2.6
50.5
63.5
2.6
138.5
34.5
44.5
54.5
1.2
1.2
1.4
Sl.No
5
5.1
5.2
5.3
5.4
5.5
6
Description
WATER TANK (RCC ONLY)
Overhaed tank without independent staging
Overhead tank upto staging height 20 metres
Overhead tank with staging height between 20 metres and upto 30 metres
Overhead tank with staging height between 30 metres and 40 metres
Underground sump
DEVELOPMENT OF SITE
Rates in Rupees
20.00/Litre.
35.00/Litre
40.00/Litre
50.00/Litre
20.00/Litre.
4400.00/sqm of
ground floor
Item
FOUNDATION
Super structure
1.1
1.2
1.3
2.1
2.2
Sl No.
3.1
3.1.1
3.1.2
Type-IV
&
Type-V/IV
Window
Door
Type -IV
Pressed steel frames
made out of corrosion resistant
coated Sheet of 1.6mm thick
with double rebate/scratch
proof aluminiumsheets/
polypropylene
3.2
Shutters
Window
3.2.2
Main Door
Double door, one with iron grill with wire mesh mosquitoproof
and other35mm thick panelled shutter with hard wood style and rail
with panelling of pre-laminated particle board, one side
decorativeother side balancinng.
3.2.3
W.C/Bathroom
3.2.1
3.2.4
Kitchen door
3.2.5
Other doors
3.3
Fittings
Powder coated
alluminium/stainless steel
fittings.
3.4
Yes
Yes
Yes
ANNEXURE-II
Hostel
Foundation
Type-V/VI
Same as Type IV
Same as Type IV
Same as Type IV
Same as Type IV
Sl No.
approv
d design.
Item
Flooring
bedrooms/
living rooms
Type-IV
4.2
Kitchen,internal
circulation area
4.3
Common
circulation area,
staircase
4.4
4.5
Toilets
4.6
Skirting/Dado in
tiolets
5
5.1
5.2
Finishing
External
Internal
Premium Acrylic
Smooth exterior finish
with additive of silicone or
washed mosaic plaster in
ordinary cement or
exposed brick work.
Type- V/VI
Grey/Beige colour rectified
ceramic floor tiles
(size 16" X 16" Matt finish) of
approved design
Same as Type- IV
Premium Acrylic
Smooth exterior finish with
additive of silicone or
washed mosaic plaster in
ordinary cement or exposed
brick work.
ITEM
KITCHEN
TYPE-II
TYPE-III
TYPE-IV
Yes
Yes
Yes
Same as Type-I
Same as Type-I
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
TYPE-I
WARDROBES
One
One
One
One
Kota Stone
Kota Stone
Kota Stone
Kota Stone
All rooms
All rooms
All rooms
All rooms
TYPE-V/VI
Same as Type-IV
Same as Type-IV/Vitreous
china sink with draining board
Yes
ITEM no
TYPE-I
TYPE-II
TYPE-III
One WC Pan
Orissa
pattern with low
level PVC
flushing
cistern
One same as
type-I
One same as
type-I
One
One
One
4 PTMT
One PTMT
One PTMT
4PTMT
One PTMT
One PTMT
4 C.P. Brass
One PTMT
One PTMT
2(a)
3
4
5
6
One
One
One
8
9
One
-
One
-
One
-
500 Ltr
500 Ltr
500 Ltr
10
Storage Tank
11
Nitch wit Kota stone sill in bath room
One
One
One
12
Plumbing for water purifier and geyser
Yes
Yes
Yes
Note: Waste coupling in wash basins and grating over the floor trap shall be only of PTMT
OL RESIDENTIAL QUARTERS
TYPE-IV
TYPE-V/VI
One+One
for servant quarter
Two
Three
Two
Two
Three
Three
1000 Ltr + 500 for servant
quarter
3 + 1 for servant quarter
Yes
750 Ltr
Two
Yes
1
2
3
4
5
6
7
8
9
10
ITEM
Power Points (15 amperes , 6 Pins)
MCB connected socket outlet for A.C
unit/Geyser complete with wiring
Celing fans
Exhaust fans
Call bells
Light/fans/Call bell/5A plu points
F.I Fittings excluding Tube and Starter
Type of wiring
EBD MCB type
A. single phase
B. Three(3) phase
Cable TV point
Telephone point
TYPE-I
TYPE-II
TYPE-III
TYPE-IV
TYPE-V
2
1
1
17
2
3
1
1
20
3
4
2
1
23
4
5
2
1
27
5
6
3
2
38
7
1
1
-
1
1
-
Concealed
1
1
1
1
2
2
conduit wir
AL QUARTERS
ealed
TYPE-VI
7
3
3
44
8
1
5
1
conduit wiring
1
2
2
1
-
DESCRIPTION
FOUNDATION
SUPER STRUCTURE
INTERNAL PARTITION
Door shutters :
3.2
3.2.1
3.2.2
3.2.3
3.3
3.4
3.5
4
4.1
4.2
4.3
4.4
4.5
4.6
5
Window shutters
Flittings
Fire check door
FLOORING
Main entrance hall
Corridors
Rooms
Lavatory Blocks
Flooring in basement
Rest of the area
STAIRCASE
5.1
Internal Staircase
5.2
6
7
8
8.1
8.2
9
9.1
External
9.2
9.2.1
9.2.2
9.2.3
9.2.4
Internal
9.3
10
11
Painting
PROVISION FOR
BARRIER FREE BUILDING
LANDSCAPING
Panelled type in 2nd class teak wood or flush door with teak veneered ply/commercial ply as per CPWD specifications/as
per design.
Anodized/powder coated/polyester powder powder coasted Aluminium shutters with float glass panelling where required.
PVC/FRP door frames and shutters in wet areas.
Factory made Anodised/powder coated/polyester powder coated 'Z' section aluminium frames & shutters for windows.
Anodized aluminium / stainless dteel or equivalent.
As per fire safety specification
Per polished granite flooring.
Matt finishewd Vitrified tiles/Granite flooring.
Granite tiles/Vitrified tiles/Ceramic tile flooring.
Granite flooring.
Vaccum dewarted concrete
Kota stone flooring.
Singkle piece Granite or marble flooring in treads & risers with dado of matching permanent finish
specification.
Single piece Kota stone flooring in treads & risers with dedo of matching permanent finish specifications.
Stainless steel railings.
Granite flooring. Glazed tiles of size not less than 300x450 mm dado.
Coba treatment
Flase celing in office area & Toilets to cover the services as per design requirment.
Dry stone cladding, washed grit plaster, water proof weather coat paints, structural glazing.
ACP cladding conforming to Energy Conservation Building Code.
Gypsum plaster in dry areas.
Cement plaster in wet areas.
Dry distemper in service area & basement.
Oil bound distemper/Acrylic emulsion paint/Textured paints.
Doors & Windows-Painting/Polishing on wood work as per design requirment.
Ramps, Toilets for physically challenged, chequered tiles use of Braille signages & lifts ect.
GRC (Glass reinforced concrete) tiles in Ramp area.
10% of the Building cost will be kept in perminary Estimate for murals and/Landscape related
construction i/c pavement/ paying.
In order to ensure the adoption of a uniform method of working out plinth areas from plans, the following rules are laid down.
These rules are general in nature and should be taken as a guide. At picture of the covered floor area provided in the plan.
GENERAL
a) The total plinth area of a building shall be the sum of the plinth area at every floor including the basement,if any.
b) Internal sanitary shafts shall not be included in the plinth area in the case of a residential building at any floor level.
c) The case of non-residential building internal shafts for sanitary installations, air-conditioning owers,turrducts lifts etc. shall be included
in the plinth area at all floor levels.
MUMTY
TERRACE PLAN
d) The area of the mumty at terrace level shall not be included in the plinth area. If a Barsati is provided jointly with mumty then the area of
Barsati excluding mumty at the terrace level shall be included in the plinth area as shown in the hatched area.
e) Towers, turrets domes projecting above the terrace shall not be inluded in the plinth area at terrace level, but shall be allowed for
separately for costing purposes.
PLINTH AREA OF GROUND FLOOR
The plinth area of the ground floor shall be calculated at the plinth level excluding the plinth off-sets provide such plinth
off-sets are not more than 21/4
In cases where the building consists of columns projecting beyonds cladding, the plinth area shall be taken up to the external fac
of the cladding and shall not be included the projections of the columns.
In case open verandah with parapets are protected at the ground floor projecting out of the building,the full area shall be taken
up to the outer line of the external verandah lintel and only 50% of area shall be taken for the unprotected verandah.Open platform without
parapets and terraces at ground floor and porches, shall not be included in the plinth area but shall be allowed for separately for costing
purposes.
be included in the plinth area even though they may occur at the floor level,vertical sun breakers or box louvers projecting out also shall
not be included in plinth area. See illustrative sketch below :
In the case of projecting balconies protected to their full width by the shades full width roof projections or by upper in the case of
unprotected balconies equivalent area to the extent of 50% of the area of the balconies shall be included in the plinth area.See illustrative
sketch given below :
(a) Area galleries i.e. upper floor of seats in an assembly hall, Auditorium, theatres,, etc. shall be fully included in the plinth area.
(b) Area of mezzanine floor i.e.an intermediate floor introduced between two main floors shall be included in the plinth area,
if no separate provision is made for the same.
(c ) The area of a loft i.e. an intermediate slab just beneath the floor of roof without any direct staircase leading to it and used for
storage purpose shall not be included in the plinth area.
MIZORAM
ANNEXURE-III
l be allowed for
de such plinth
W.D (Buildings)
DESCRIPTION
2
ITEM no
OFFICE
3
4
1.1
Bearing capacity 10 tonnes/ square metre.
FOUNDATION
1.2
TYPE - Spread foundations isolated/combined
1.3
Depth - Upto 1.2 metres below ground level.
RCC framed construction with filler walls
in brick work or load bearing
construction in brick/stone mansory with
SUPER STRUCTURE
2.1
intermediate columns where found
necessary.
2.2
2.3
3.1
3.2
3.3
3.4
HOSPITAL
5
InternalFrames of 2nd class Indian teakwood or equivalent ot T-iron frame, presses steel frame as
Door shutters; Panelled type in 2nd class teak wood or flush door with commercial ply as per CPWD
FLOORING
4.1
4.2
5
ROOFING
FINISHING
5.1
5.2
6.1
6.2
6.3
Annexure -v
SCHOOLS
6
or equivalent
1.1
Item
Foundation
1.3
Super structure
3.1
3.1.1
3.1.2
Applicable to all
2.2
SL no.
Type-IV
1.2
2.1
Item
Frames
Window
Door
Type-IV
3.2
SHUTTERS
Window
3.2.2
Main door
3.2.3
W.C/Bath room
3.2.1
Kitchen door
3.2.5
Other doors
3.3
Fitting
3.2.4
3.4
NOTE :
SL no.
4
4.1
Yes
In items no.3 of wood works, if any other option of local material is available, the same can also be used by the r
External sliding door bolt and handles will be in powder coated M.S or stainless steels.
Koba treatment on roofing in all type of quarters.
Type-I, II. III & Servant Qtrs
Common
Kota stone flooring and matching skirting. In
4.2
circulation
staircase, single
area, stairecase piece Kota stone shall be used.
4.3 Kitchen and work topKota stone
4.4
Toilets
Mosaic
4.5
Skirting/Dado
Finishing
5.1
External
Yes
Type-IV
5.2
Internal
Type-V/VI / Hostel
Applicable to all
Type-V and VI
Same as Type - IV
Same as Type - IV
Same as Type - IV
Yes
Type-V and VI
Type-I
Type-II
Type-III
yes
Yes
Yes
Same as
type-I
Same as
type-I
Stainless steel
sink without
drain board
size 610 x 510
mm with bowl
depth 200 mm
(iii)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(iv)
(v)
2(i)
(ii)
(iii)
(iv)
(v)
Wardrobes
Built in cupboard wutg R.C.C./
pre-laminated particle board/
kota stone shelves and shutter
upto ceiling height
Magic eye in front door
Window sill lining 18mm thick
projected with kota stone/
marble
Curtain rods with brackets
Set of pegs
One in each
Bed Room 7`00" height
One
One
One
Kota Stone
Kota Stone
Kota Stone
All rooms
All rooms
All rooms
In Bath and
bed rooms
In Bath and
bed rooms
In bath,bed and
wardrobes
AL POOL ACCOMODATION
Type-IV
Type-V/VI
Same as type-IV
Yes
Yes
Yes
One
One
Kota Stone
Marble
Drapery rods
Drapery rods
In bath,bed and
wardrobes
Type-I
type-II
Type-III
One same as
Type-I
One same as
Type-I
One
One
One
4 PTMT
4 PTMT
4 C.P. brass
One PTMT
One PTMT
One PTMT
One PTMT
One PTMT
One PTMT
One
One
One
One
-
One
-
One
-
500 ltr.
500 ltr.
500 ltr.
One
One
One
2(a)
3
5
6
7
8
9
10
Stroage tank
11
Note :
Waste coupling in wash basins and grating over the floor trap shall be only of PTMT.
L RESIDENTIAL QUARTERS
Type-IV
Type-V/VI
One
One
Two mixer type for hot Three mixer type for hot
and cold water
and cold water
5 C.P. brass
Two
Three
Two
Two
Three
Three
1000 ltr + 500 ltr.
For servant quarters.
750 ltr.
Two
3+1
for servant quarters.
9
10
Type-I
2
type-II
3
Type-III
4
Type-IV
5
Type-V
6
2
1
1
17
2
3
1
1
20
3
Recessed Conduit wiring
4
1
1
23
4
5
1
1
27
5
1
1
-
1
1
-
1
1
-
1
1
1
6
1
2
38
7
Concealed conduit wiring
1
2
2
DENTIAL QUARTERS
Type-VI
7
7
1
3
44
8
ncealed conduit wiring
1
2
2
1
5
1
1
-