Procedure
1-Connect the Ethernet cross wire between the touch screen and computer.
Ethernetport
2-Disconnect the power supply of touch screen, wait 5 seconds and reconnect, after 20 seconds touch screen shows the
follow menu.(This menu runs only 3 or 4 Seconds), press Control panel.
PressControl
panel
Doubleclick
inTransfer
4-The next screen appears, tilt and set the options like the next example. And press the button advance.
Setthisoptions
PressAdvanced
5-In the next screen press onboard LAN Ethernet Driver after this press properties
Setthisoption
PressProperties
6-In the next screen tilt Specify an IP address and set IP address 192.168.56.198 And set Subnet Mask 255.255.255.0.
7-Press OK in all the screens until the next screen (see picture), and double click in OP.
Doubleclick
inOP
PressDevice
Press
Reboot
10-The touch screen start to reboot, after 20 second appear the Loader menu. Press Transfer in the screen appear the
message connecting to host.
PressTransfer
11-Computer Settings.
You must to set in the Lan -internet properties The IP address 192.168.56.196 And the Subnet mask 255.255.255.0
(Note that the IP address in the touch screen is not the same than the IP address in the computer).
Disconnect and reconnect the Ethernet wire and wait that the computer Recognize the connection. And
ready, the touch screen is connected.
12-Start the WinCC Flexible Program clicking in the .hmi touchscreen program file, and set in transfer the Ethernet
mode and the IP address 192.168.56.198 ( the same IP address than the touchscreen).
13- Set the parameters of the transfer. And click in transfer in order to start the transferring.