100% found this document useful (3 votes)
7K views4 pages

KU To CentiPoise

This document provides a three step process to convert between Stormer Viscometer Krebs units and viscosity cup drain time measurements. Step 1 involves using a chart to convert Krebs units to centipoise viscosity. Step 2 uses another chart to convert the centipoise value to centistokes. Step 3 determines the drain time in seconds for a viscosity cup using the centistoke value and another conversion chart. The conversion is only accurate for Newtonian or near-Newtonian materials.

Uploaded by

Una Si Ndéso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
7K views4 pages

KU To CentiPoise

This document provides a three step process to convert between Stormer Viscometer Krebs units and viscosity cup drain time measurements. Step 1 involves using a chart to convert Krebs units to centipoise viscosity. Step 2 uses another chart to convert the centipoise value to centistokes. Step 3 determines the drain time in seconds for a viscosity cup using the centistoke value and another conversion chart. The conversion is only accurate for Newtonian or near-Newtonian materials.

Uploaded by

Una Si Ndéso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

CONVERSION between

STORMER VISCOMETER KREBS UNITS


and VISCOSITY CUP DRAIN TIME

Paul N. Gardner Company, Inc.

316 NE 1st ST, POMPANO BCH, FL 33060


1-800-762-2478 (954) 946-9454 FAX (954) 946-9309

PU-G271 01-18-99

CONVERSION between STORMER VISCOMETER KREBS UNITS


and
VISCOSITY CUP DRAIN TIME

THREE STEP CONVERSION PROCESS


Step 1: Knowing the Krebs value, convert this value to Centipoise
viscosity. On the attached Krebs Units to Centipoise conversion chart,
read vertically from the known Krebs unit to the curve and then horizontally to the left to the Centipoise value. Record this value.
Step 2: Convert the Centipoise value for the test material in question
to Centistokes. On the attached Centipoise - Centistoke conversion
chart, locate the Centipoise value from Step 1 on the vertical scale.
Read horizontally to the right from this value to the Weight Per Gallon
or Specic Gravity line, estimating values between lines, applicable
to the test material in question. From this intersection read directly
downward to the horizontal Centistoke scale and record this value.
Step 3: Determine the drain time in seconds for the viscosity cup in
question from the Centistoke value from Step 2. For this conversion,
refer to the Gardco Viscosity Cup Equivalent Chart or the conversion
chart furnished with each Gardco produced viscosity cup.
Only viscosity cups accommodating the highest range of viscosity
are satisfactory for this conversion as most Krebs measurements are in
the range from 500 to 1400 Centistokes. For satisfactory results, do not
use a viscosity cup above its recommended top limit.
This conversion is accurate only for Newtonian or near Newtonian materials. Viscosity of materials that deviate greatly from these true liquids
may not be seen the same by the Stormer and viscosity cup methods
of measurement.

Paul N. Gardner Company, Inc.

316 NE 1st ST, POMPANO BCH, FL 33060


1-800-762-2478 (954) 946-9454 FAX (954) 946-9309

THIS GRAPH IS BASED ON THE BEST AVAILABLE INFORMATION


BUT IS NOT CONFIRMED EXPERIMENTALLY BY THE PAUL N. GARDNER COMPANY

FURNISHED AS A COURTESY OF THE PAUL N. GARDNER COMPANY

KREBS UNITS TO CENTIPOISE VISCOSITY CONVERSION

* 8.32 = **