Section-I General Information & System Data Climatic Conditions

The document provides climatic and system data for a power transmission project located in Gujarat, India. Key details include: - Maximum and minimum temperatures of 50C and 0C respectively, with average daily temperature of 35C - High annual rainfall of 1150mm and thunderstorms on 15 days per year on average - The transmission system operates at 220kV with a maximum voltage of 245kV - Tower heights range from 525m to 0m depending on the tower type and wind/broken wire conditions - Conductors include an ACSR Zebra configuration with 54/3.18mm aluminum and 7/3.15mm steel strands
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views2 pages

Section-I General Information & System Data Climatic Conditions

The document provides climatic and system data for a power transmission project located in Gujarat, India. Key details include: - Maximum and minimum temperatures of 50C and 0C respectively, with average daily temperature of 35C - High annual rainfall of 1150mm and thunderstorms on 15 days per year on average - The transmission system operates at 220kV with a maximum voltage of 245kV - Tower heights range from 525m to 0m depending on the tower type and wind/broken wire conditions - Conductors include an ACSR Zebra configuration with 54/3.18mm aluminum and 7/3.15mm steel strands
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

SECTION-I

GENERAL INFORMATION & SYSTEM DATA


CLIMATIC CONDITIONS

i) Location : In the State of Gujarat .


ii) Maximum Ambient Air Temperature. C. : 50
iii) Minimum Ambient Air Temperature. C. : 0
iv) Average daily ambient Air Temperature C. : 35
v) Maximum relative humidity. - % : 95
vi) Average rainfall per annum.(mm) : 1150
vii) Maximum altitude above mean sea level Mtrs : 1000
viii) Ceraunic level i.e. Average number of
Thunder storm Days/annum : 15
ix) Maximum wind pressure.(kg/Sq. meters) 200
ix) Seismic level i.e. Earthquake Acceleration
a) Horizontal Seismic Co-efficient
(acceleration) g (Zone 5) : 0.08
b) Vertical Seismic Co-efficient
(acceleration) g (Zone 5) : 0.84

SYSTEM PARTICULARS

a) System Voltage (KV rms) 220


b) Max. Voltage (KV rms) 245
c) Lightning impulse withstand voltage (dry &
wet) (KVP) 1050
d) Power Frequency withstand voltage (wet) (KV
rms) 460
e) Short circuit level (KA) 40
f) Switching Surge withstand voltage (wet) KVP NA
g) Frequency Hz
a) Normal 50
b) Maximum 51
III) Minimum 47
h) Number of Circuits 02 & 04
i) Normal Span m 350
j) Wind Span m 385

k) Weight Span m
a) Maximum 525
b) Minimum -100
l) Factor Of Safety (At Every Day Temp. & No Wind) 04

TOWER DETAILS
TOWER TYPE NORMAL CONDITION
MAX. (m)
MIN. (m)
(m)
A
525
175
B
525
0
C
525
0
D
525
0

BROKEN WIRE CONDITION


MAX. (m) MIN.
315
315
315
315

100
-200
-200
-300

DETAILS OF LINE MATERIALS


A. Conductor and Earth wire for 220 KV Single Conductor line
Sl. No. Description Unit Earth wire Conductor
Name/Type Galvanized ACSR Zebra
steel
B. 2. Size mm 7/3.15 54/3.18Aluminium
C. +7/3.18 steel
D. 3. Configuration One continuously
E. To run horizontally
F. On the top of the
G. Towers & conductors
H. 6. Overall diameter mm 09.45 28.62
I. 7. Unit mass Kg/Km. 426 1621
J. 8. Min. UTS KN 58.4 130.30
K. 9. Ruling Design Span Meters 350 350
L. 10. Area of cross-section mm^2 545.5 484.50 mm^2