Overall Heat Balance - 11.08.2008

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 8

Arasmeta cement plant - Kiln Audti traning 11.11.

2008
Ref Temp.
Basis
Input
KF
Coal sinsible heat
Cooling Air
Coal moisture
Primary Air
Transport Air
GCT Water
Heat Consumption
Kiln
Calciner
False Air
KF Moisture
Total

Output
KS exit gas
O2
CO2
N2
H2O
CO
CS exit gas
O2
CO2
N2
H2O
CO
Cooler Vent Gas
coal hot gas takeoff
clinker
ph dust
Kiln String
calciner string
Radiation Loss
Kiln +Ph+Cal
Cooelr
Theoretical heat of reaction

0 c
1 kg/hr of clinker
Mass Flow (kg/h) Temp
328680
30468.75
520970
781.25
5146
9462
28050
10
21.25
95125
1320
923589

Mass Flow (kg/h)

Cp(kCal/Kg)
70
70
32.5
70
60
60
25

Err:511
Err:511
Err:511
Err:511
Err:511
Err:511
Err:511

32.5
70

5321
4600
Err:511
Err:511

Temp

Cp(kCal/Kg)

Heat(kCal/hr)

Err:511
Err:511
Err:511
Err:511
Err:511 kiln axial, swirl and cooling air
Err:511 both the kiln and calciner coal
Err:511 on the basis of design data
53210000
97750000
Err:511
Err:511
Err:511

Heat(kCal/hr)

138446

7973
39705
85905
4849
14

Err:511

362
362
362
362
362

Err:511
Err:511
Err:511
Err:511
Err:511

Err:511
Err:511
Err:511
Err:511
Err:511

20437
162361
136734
46835
364

173
173
173
173
173

Err:511
Err:511
Err:511
Err:511
Err:511

Err:511
Err:511
Err:511
Err:511
Err:511

218306
7836
200000
28253
9323
18929

250
365
140

Err:511
Err:511
Err:511

Err:511 accuracy of measurement in d


Err:511
Err:511

362
173

Err:511
Err:511

Err:511
Err:511

366732

Err:511

62.3
7
84000000 For clinker formation
Err:511

output - input

Err:511

Err:511

GCT WATER SPRAY

kiln axial, swirl and cooling air


both the kiln and calciner coal blower
on the basis of design data

425 LPM
25.5 m3/hr
25500 kg/hr

Heat Consumption on basis of coal cons.


Kiln
coal cons
10 tph
Coal Cv
5321 kCal/kg
53210000 kCal/hr
266.05

Calciner
coal cons
Coal Cv

21.25 tph
4600 kCal/kg
97750000 kCal/hr

KF distribution
Calciner string
Kiln String

488.75
754.8

220
110

67%
33%

Calciner Gas Composition


Vol
Mol wt
O2
5.4
CO2
31.2
N2
41.29
H2O
22
CO
0.11

32
44
28
18
28

Kiln Gas Composition


Vol
Mol wt
O2
5.55
CO2
20.1
N2
68.339
H2O
6
CO
0.011

wt
wt%
32
177.6
5.8%
44
884.4
28.7%
28 1913.492
62.0%
18
108
3.5%
28
0.308
0.0%

wt

wt%
172.8
1372.8
1156.12
396
3.08

5.6%
44.3%
37.3%
12.8%
0.1%

accuracy of measurement in doubt.

For clinker formation

Clinkerization Factor
Ph dust%

1.65
8.6%

8.6%

Cross Checking the PH ID fan Data


with ideal GCT false air the power consumption of ID fan
PC string Outlet flow

316607 kg/hr

with GCT 3% False air and Downcomer 4% false air


the total volume should be handle by ID fan=
338770 kg/hr

False air Calculation


Analysis Data

O2
CO2
CO
N2
O2
CO2
CO
N2
wt%
O2
CO2
CO
N2

B61 o/l
B61 o/l
B51o/l
B51
B52
B53
B54
B55
GCT OL
2.43
2.79
2.57
2.43
1.98
1.76
2.24
0.37
5.43
37
37
37.6
37
38.5
39.1
34.5
39.1
31
0.1355
0.1044
0.1692
0.0983
0.1684
0.205
0.176
0.2567
0.0971
60.4345 60.1056 59.6608 60.4717 59.3516
58.935
63.084 60.2733 63.4729
77.76
89.28
82.24
77.76
63.36
1628
1628
1654.4
1628
1694
3.794
2.9232
4.7376
2.7524
4.7152
1692.166 1682.957 1670.502 1693.208 1661.845
2.29%
47.86%
0.11%
49.74%

2.62%
47.84%
0.09%
49.45%

2.41%
48.49%
0.14%
48.96%

False Air
Across GCT
50125 kg/hr
by standard values
45000 kg/hr
for all over system
False Air According to Standard Values
Calciner
0.01 kg/kk
2000
Kiln Hood
0.03 kg/kk
6000
Kiln inlet
0.03 kg/kk
6000
Cy Kiln
0.07 kg/kk
14000

2.29%
47.86%
0.08%
49.78%

1.85%
49.48%
0.14%
48.54%

56.32
71.68
11.84
173.76
1720.4
1518
1720.4
1364
5.74
4.928
7.1876
2.7188
1650.18 1766.352 1687.652 1777.241
1.64%
50.12%
0.17%
48.07%

2.13%
45.17%
0.15%
52.55%

0.35%
50.20%
0.21%
49.24%

5.24%
41.11%
0.08%
53.57%

measured values
14% PC string
33063 kg/h
Kiln string
Kiln inlet analysis is not correct and also ccr va
take.

Cy PC

0.085 kg/kk

17000
45000

3317.72

not correct and also ccr values can not be

You might also like