86% found this document useful (7 votes)
16K views4 pages

Sieve Analysis Excel File For 20mm & 10mm Aggregate

The inspection report summarizes the results of a sieve analysis test conducted on a sample of fine aggregate collected from the LNG Regasification Terminal project in Ennore, India. A 1710 gram sample was tested through a series of sieves to determine the particle size distribution. The test found that 99.59% of the sample passed through a 0.15 mm sieve, meeting the specifications of the Indian Standard Code which requires 0-10% passing a 0.15 mm sieve for fine aggregate. The fine aggregate sample met all other specifications and is approved for use in the project.

Uploaded by

pratimwhite
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
86% found this document useful (7 votes)
16K views4 pages

Sieve Analysis Excel File For 20mm & 10mm Aggregate

The inspection report summarizes the results of a sieve analysis test conducted on a sample of fine aggregate collected from the LNG Regasification Terminal project in Ennore, India. A 1710 gram sample was tested through a series of sieves to determine the particle size distribution. The test found that 99.59% of the sample passed through a 0.15 mm sieve, meeting the specifications of the Indian Standard Code which requires 0-10% passing a 0.15 mm sieve for fine aggregate. The fine aggregate sample met all other specifications and is approved for use in the project.

Uploaded by

pratimwhite
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

INSPECTION REPORT

SIEVE ANALYSIS
(FINE AGGREGATE)
Project

LNG Regasification Terminal -Ennore

Project No.

Client

IOLPL

BV Project No.

Consultant

AMEC Foster Wheeler

Report No.

EPC Contractor

Consortium-BV & KSS EPCC-02

Date

Ref. Drawing No.

Location

Weight of Sample
Sampled by

SL NO

1
2
3
4
5
6
7
8

KSS

Date of Testing

SIEVE SIZE

WEIGHT
RETAINED
(grams)

% WEIGHT
RETAINED

CUM. % WIEGHT
RETAINED

10 mm

4.75 mm

77

4.50

4.50

2.36 mm

186

10.88

15.38

1.18 mm

374

21.87

37.25

0.6 mm

425

24.85

62.11

0.3 mm

388

22.69

84.80

0.15 mm

245

14.33

99.12

Pan

0.47

99.59

1703
RESULTS :

Description

KSS/BV

NAME
SIGN
DATE

Form no. 189150.CIV.QC.010 REV 2

PMC

REPORT

SIS
ATE)
Project No.

19200

BV Project No.

189150

Report No.

87.1400/SA/FA/08

Date

07-04-16

Location

Batching Plant

Weight of Sample

1710 gms

Date of Testing

07-04-16

% PASSING

% PASSING
(As per IS:383)

100

100

95.50

90 - 100

84.62

75 - 100

62.75

55 - 90

37.89

35 - 59

15.20

8 - 30

0.88

0 - 10

0.41

REMARKS