Concrete Table Spec

This document provides specifications for concrete mixes of different grades based on their compressive cube strength at 7 and 28 days, maximum aggregate size, water-cement ratio, minimum cement content and other notes. The grades range from 65/20 to 15/20 and specify the target compressive strengths for preliminary and works tests as well as requirements for aggregate size, water-cement ratio and cement content.

Uploaded by

Michael Teo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
236 views1 page

Concrete Table Spec

This document provides specifications for concrete mixes of different grades based on their compressive cube strength at 7 and 28 days, maximum aggregate size, water-cement ratio, minimum cement content and other notes. The grades range from 65/20 to 15/20 and specify the target compressive strengths for preliminary and works tests as well as requirements for aggregate size, water-cement ratio and cement content.

Uploaded by

Michael Teo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Grade

65/20
60/20
55/20
50/20
45/20
40/20
35/20
30/20
25/20
25/40
20/20
15/40
15/20
Note :

Max Size of
Aggregates
(mm)
20
20
20
20
20
20
20
20
20
40
20
40
20

Compressive Cube Strength N/mm2


Preliminary Test (Mean)
Works Test (min.)
7 Days
28 Days
7 Days
28 Days
51.1
73.0
45.5
65.0
47.6
68.0
42.0
60.0
44.1
63.0
38.5
55.0
40.6
58.0
35.0
50.0
25.9
37.0
31.5
45.0
33.6
48.0
28.0
40.0
30.1
43.0
21.0
30.0
22.4
32.0
21.0
30.0
22.4
32.0
17.5
25.0
18.9
27.0
17.5
25.0
21.0
30.0
14.0
20.0
15.0
15.0

Max
Water/Cement Min Cement
Ratio
Content kg/m3
0.35
530
0.35
500
0.35
480
0.40
430
0.40
420
0.40
380
0.45
350
0.55
310
0.60
280
0.60
280
0.65
260
0.70
0.70
-

a) Cement type CEM I & CEM II only allowed and shall be in accordance to BS 8500-1:2015, BS 8500-2:2015 and BS EN 206-2013
b) Maximum pulverized fly ash content or ground granulated blast furnace slag content shall be limited to 35%