QUESTION BANK
Year: 2015-16
Subject :
Class:
June / July 2011 : 08 Marks, June / July 2009 : 06 Marks, Dec 2014 / Jan 2015 :
06 Marks
What are the limitations involved in design of electrical machines.
Or
Explain the limitations in design of electrical machines
2.
3.
June / July 2014 : 10 Marks, Dec 2013 / Jan 2014 : 08 Marks, June / July 2013 :
06 Marks, Dec 2012 : 06 Marks, June 2012 : 12 Marks, Dec 2011 : 07 Marks,
June / July 2011 : 08 Marks, Dec 2010 : 08 Marks, Dec 09 / Jan 2010 : 10 Marks,
May / June 2010 : 10 Marks,
List the desirable properties of insulating materials. Give the classification of
insulating materials based on thermal considerations with examples used in
each class
4.
5.
Dec 2015 / Jan 2016 : 6 Marks, Dec 2014 / Jan 2015 : 06 Marks, Dec 2013 / Jan
2014 : 05 Marks, June 2012 : 08 Marks, Dec 2011 : 08 Marks, June / July 2011 :
08 Marks, Dec 2010 : 08 Marks
From the first principles derive the output equation of DC Machine
2.
3.
Question Bank
-574240, INDIA
2015-16 :
5.
6.
June / July 2015 : 08 Marks, June / July 2014 : 04 Marks, Dec 2013 / Jan 2014 :
08 Marks, Dec 09 / Jan 2010 : 06 Marks
Describe how specific electric and magnetic loadings play an important role in
the design of electrical machines
Or
Define specific loadings and mention the advantages of choice of higher
values of specific loadings in the design of any machine
7.
Dec 2014 / Jan 2015 : 05 Marks, Dec 2011 : 07 Marks, June / July 2009 : 06
Marks
State the factors affecting the value of electrical loading in case of a DC
Machine
8.
June / July 2014 : 06 Marks, Dec 2013 / Jan 2014 : 04 Marks, June / July 2009 :
06 Marks, Jan / Feb 2006 : 12 Marks, Dec 2013 / Jan 2014 : 04 Marks, June /
July 2013: 04 Marks, Dec 2011 : 06 Marks
Discuss the factors that should be given due considerations while selecting
number of poles for DC Machine
Or
Mention the various factors that affect the choice of number of poles of a DC
Machine
Or
What are the advantages and disadvantages of large number of poles in DC
Machines?
9.
Question Bank
-574240, INDIA
2015-16 :
rpm, 4 Pole DC Shunt Generator. The average flux density is 0.7 T and AC/m is
34,000. The ratio of core length to pole pitch is 0.8. Full load armature drop is
9.6 V and field current is 3.0 A.
16. Dec 2014 / Jan 2015 : 10 Marks.
Determine the main dimensions,
number of poles and length of air gap for a 600 kW, 500 V, 900 rpm generator.
Assume : Barc = 0.6 T, (MMF)A4 = 50 % (MMF)Arm , ac / m = 35000, Pole arc /
Pole pitch = 0.75, efficiency = 91 %, Kg = 1.15
17. June / July 2014 : 10 Marks, Dec 2013 / Jan 2014 : 07 Marks, June / July 2011 :
12 Marks
A Design s required for a 50 kW, 4 Pole, 600 rpm, DC Shunt Generator, the full
load terminal voltage being 220 V. If the Bmax = 0.83 Tesla and ac / m = 30,000,
calculate suitable dimensions of armature core. Assume that the full load
armature voltage drop is 3 % of rated terminal voltage and that the field
current is 1.0% of rated full load current. Ratio of pole arc to pole pitch is
0.67.
18. Dec 2007 / Jan 2008: 10 Marks, Jan / Feb 2006 : 12 Marks
Calculate the main dimensions of a 20 hp, 1000 rpm, 400 V, dc motor. Bav =
0.37 T, ac = 16000 ac/m. efficiency = 90 %. Choose a suitable number of poles
and justify the selection.
19. June / July 2013: 10 Marks
A 5 kW, 250 V, 4 Pole, 1500 rpm shunt generator is designed to have a square
pole face. The loadings are:
Average flux density in the air gap = 0.42 wb / m2, ampere conductors per
metre = 15000. Find the main dimensions of the machine. Assume full load
efficiency = 87 % and ratio of pole arc to pole pitch = 0.66.
20. Dec 2007 / Jan 2008: 12 Marks.
Design a 50 kW, 4 pole, 600 rpm dc shunt generator. The full load terminal
voltage being 220 V. if the maximum gap density is 0.83 T and ac = 30000
ac/m. calculate the suitable dimensions of armature core to give a square pole
face. Assume that the full load armature drop is 3 % of the rated terminal
voltage and the field current is 1 % of the full load current. Ratio of pole arc to
pole pitch = 0.67.
21. June / July 2013: 10 Marks
Determine the total commutator losses for a 1000 kW, 500 V, 300 rpm, 10
Pole, dc generator. Diameter of the commutator = 100 cm, current density for
the brush = 7.50 A / cm2, brush pressure = 1500 kgf / m2. Assume lap winding,
brush contact drop = 2 V. coefficient of friction = 0.20, armature current = F.L
current
22. December 2012: 14 Marks
A 150 kW, 230 V, 500 rpm, DC shunt motor has square field coil. Find the
number of poles, main dimensions and air gap length. Assume Bav = 0.85 T,
ac / cm = 290, ratio of width of the pole body ot pole pitch = 0.55, ratio of
pole arc to pole pitch = 0.70, efficiency = 91 %, take mmf for air gap = 55 % of
armature mmf, gap contraction factor = 1.15
23. June / July 2015 : 08 Marks
Determine the main dimensions, number of poles, number of armature
conductors, number of slots, conductors per slot and the size of armature
conductors and cross sectional area of armature conductors for A 250 kW, 400
V, 625 A, 600 rpm, lap wound DC compound assuming the following data:
Average flux density in the gap = 0.63 T, Specific Electric Loading = 33000
amp conductors / mh ; field and armature copper losses = 5 % of output; ratio
Question Bank
-574240, INDIA
2015-16 :
of pole arc to pole pitch = 0.70, pole arc = gross length of armature, armature
drop = 3 % of terminal voltage, current density = 5 A / mm 2, slot pitch = 2.6
cm
24. December 2012: 12 Marks, June / July 2009 : 12 Marks
A 250 kW, 500 V, 600 rpm, DC Generator is built with and armature diameter
of 75 cm and a core length of 30 cm. The lap connected armature has 720
conductors using the data obtained from this machine, determine the
armature diameter, core length, number of armature slots, armature
conductors and commutator segments for a 350 kW, 440 V, 720 rpm, 6 Pole DC
Generator. Assume a square pole face with ratio of pole arc to pole pitch equal
to 0.66. The full load efficiency is 0.91 and to internal voltage drop is 4 % of
the rated voltage. The diameter of commutator is 0.70 of the armature
diameter. The pitch of commutator segments should not be less than 4 mm.
the voltage between adjacent segments should not exceed 15 V at no load.
25. December 2012: 08 Marks
During the design of armature of a 1000 kW, 500 V, 10 Pole, 300 rpm, DC
compound generator following details are obtained: External diameter of
commutator = 140 cm; Gross length of the core = 35 cm; Flux / Pole = 0.105
wb. Based on the above details, find out the following details regarding the
field system design
i. Axial length of the pole, ii. Width of the pole, iii. Height of the pole, iv. Pole
arc, v. Depth of the yoke
Assume the permissible loss of the cooling surface = 700 W / m 2, leakage
factor for the pole 1.2, flux density in the pole = 1.6 Tesla, Iron factor for the
pole = 0.95, winding type = Lap connected, voltage drop = 10 V, ratio of field
ampere turns to the armature ampere turns on full load = 1.2, depth of the
winding = 5 cm, copper space factor for the field winding = 0.6, pole shoe
thickness at the centre of the pole = 3.6 cm, ratio of pole arc to pitch of the
pole = 0.68, flux density in the yoke = 1.5 times gross armature length. Axial
length of pole = 1 cm less than gross length of armature.
26. June 2012 : 10 Marks, May / June 2010 : 10 Marks
Calculate the diameter and length of armature for a 7.5 kW, 4 Pole, 1000 rpm,
220 V DC Shunt Motor. Given that full load efficiency = 0.83, Maximum flux
density = 0.9 wb / m2; ac = 30000 AC/m; field form factor = 0.70; assume that
the maximum efficiency occurs at full load and field current is 2.5 % of rated
current. The pole face is square.
27. Dec 2011 : 12 Marks
Determine the main dimensions, number of pole and length of air gap of a 600
kW, 500 V, 900 rpm generator. Assume average gap density as 0.60 T and ac =
35000 AC / m. The ratio of pole arc to pole pitch = 0.75, and efiiciency = 91 %.
The following are the design constraints: peripheral speed
40 m / sec;
frequency of the flux reversal
armature mmf per pole
400 A; the
Question Bank
-574240, INDIA
2015-16 :
Question Bank
-574240, INDIA
2015-16 :
i). Axial length of the pole, ii). Width of the Pole, iii). Height of the Pole.
Permissible loss per square meter of the cooling surface may be assumed as
700 W / m2. Assume leakage factor of the pole Kl = 1.2, flux density in the pole
BP = 1.6 Tesla, Iron factor ki = 0.95, voltage drop as 2 % of rated voltage, ATf =
1.2 ATa , Copper space factor Sf = 0.60 and depth of the winding as 0.05 m and
thickness of the pole shoe = 4 cm
37. Dec 2015 / Jan 2016 : 10 Marks, Dec 2007 / Jan 2008: 10 Marks
A shunt field coil has to develop an mmf of 9000 AT, the voltage drop in he
field coil = 40 V, resistivity of round wire = 0.021 / m / mm 2. The depth of
the winding = 35 mm, length of mean turn = 1.4 m. design a coil so that the
power dissipated = 700 W / m2 of the total coil surface. Take the diameter of
insulated wire to be 0.2 mm greater than bare wire.
Dec 2014 / Jan 2015 : 06 Marks, June / July 2014 : 4 Marks, Dec 2011 : 10
Marks, Dec 2010 : 10 Marks, Jan / Feb 2006: 08 Marks
Derive the output equation of a 3 phase core type transformer, and deduce
the expression for volt / turn.
2.
3.
4.
Dec 2014 / Jan 2015 : 10 Marks, June / July 2014 : 10 Marks, Dec 2013 / Jan
2014 : 10 Marks, June 2012 : 10 Marks, Dec 2010 : 10 Marks, May / June 2010 :
12 Marks, Dec 2007 / Jan 2008: 10 Marks, Jan / Feb 2006: 08 Marks, June / July
2015 : 10 Marks
Derive an expression for the total leakage reactance of a transformer,
referred to the primary
5.
Dec 2015 / Jan 2016 : 08 Marks, Dec 2014 / Jan 2015 : 10 Marks, Dec 2007 / Jan
2008: 10 Marks
A 1, 440 V, 50 Hz transformer is built I form of stampings having a relative
permeability of 1000. The length of the flux path is 2.5 m, the area of cross
section of the core = 2.5 x 10-3 m2 and the primary winding has 800 turns.
Estimate the maximum flux and the no load current of the transformer.
Assume: loss at i) working flux density = 2.6 w / kg; ii) Iron weight = 7.8 x 10 3
kg/m3; iii) stacking factor = 0.90
6.
Question Bank
-574240, INDIA
2015-16 :
7.
June / July 2014 : 04 Marks, June 2012 : 5 Marks, June / July 2015 : 10 Marks
Derive the expression for the no load current of the transformer.
Or
Explain the procedure to determine the no load current of the transformer.
8.
June / July 2014 : 10 Marks, June / July 2009 : 10 Marks, June / July 2015 : 10
Marks
Calculate: i). net cross section of the core, ii). Gross area of the core, iii). Core
dimensions, iv). Window area, v). Dimensions of the window, for a 200 kVA,
6600/250V, 50 Hz, single phase shell type oil immersed transformer based on
the following design parameters:
Window Space Factor Kw = 0.28, Bm = 1.1 Tesla, Average current density = 2.2
A / mm2, stacking factor = 0.90, window proportion- = 2.5 :1, Rectangular core
proportion = 1.8 :1. Net cross section of copper in the window is 0.20 time the
net cross section of iron in the core.
9.
K Q , where Q is the
2015-16 :
Bm wb/m2
Mmf AT/m
Iron loss W /
kg
0.9
130
0.8
1.0
210
1.3
1.2
420
1.9
1.3
660
2.4
1.4
1300
2.9
K kVA . Also explain the factors to be taken into account while selecting
the value of constant K.
21. Dec 2012 : 12 Marks, June 2012 : 10 Marks
Determine the main dimensions of the core and number of turns and area of
C.S of the conductors of the primary and secondary of a 125 kVA, 6600 / 460
V, 50 Hz, single phase core type distribution transformer. Maximum flux
density in the core = 1.2 wb / m2. Current density = 250 A / cm2. Assume
cruciform for the assembled core allowing 8% for the insulation between
laminations. Take yoke cross section as 15 % greater than the core. Window.
Net cross section of copper is 0.225 times the net cross section of iron in the
Question Bank
-574240, INDIA
2015-16 :
core. Window space factor = 0.30. Draw a neat sketch to a suitable scale,
show the values.
22. Dec 2012 : 08 Marks
Calculate the overall dimensions, number of turns and cross section of the
conductors for a 200 kVA, 6600 / 440 V, delta star, 50 Hz, 3 phase core type
transformer. Given the following data: e m f / turn = 10 volts, maximum flux
density in the core = 1.3 T, current density = 2.5 A / mm2, window space
factor = 0.30, overall height = over all width. Stacking factor = 0.90, use 3
stepped core. Draw a sketch showing details.
23. Dec 2012 : 08 Marks
Design a suitable cooling tank with cooling tubes for a 500 kVA, 6600 / 400 V,
50 Hz, 3 phase, oil immersed natural cooled transformer with the following
data: temperature rise allowed for transformer tank is < 60 0C. Dimensions of
the transformer are 100 cm height, 96 cm in length, width = 47 cm, total
losses = 7 kW. Allowable temperature rise for tank walls = 35 0C. Cooling tube
diameter = 5 cm, spaced 7.5 cm, length of cooling tubes = 90 % of height of
the tank. Take clearances i) along length = 14 cm, ii) along width = 13 cm, iii)
along height = 40 cm. determine the number of tubes required and draw a
sketch showing their possible arrangement.
24. June 2012 : 8 Marks
The full load efficiency of a 300 kVA, 1 core type transformer is 98.2 % at
UPF. Design the number of cooling tubes necessary if the temperature rise is
350C. tank area may be assumed as 4.92 m2. Assume the tube diameters as 5
cm and average length of 105 cm. heat dissipation may be assumed as 12. 5
W / m2 / 0C
25. Dec 2011 : 10 Marks
Calculate the dimensions of the core, the number of turns and the cross
sections of the conductors for a 100 KVA, 2300 / 400 V, 50 Hz. Single phase
shell type transformer, assuming: ratio of magnetic and electric loading 480 X
108; maximum flux density 1.1 T; current density 2.2 X 106 A / m2; window
space factor 0.30; ratio of depth of stacked core to width of central limb 2.6;
ratio of height to width of window 2.5; stacking factor 0.90
26. June / July 2011 : 10 Marks
Derive the output equation of single phase transformer
27. June / July 2011 : 12 Marks
Find the main dimensions of a core and window for a 500 kVA, 6600 / 400V, 50
Hz, single phase core type oil immersed self cooled distribution transformer.
Assume the flux density as 1.2 T and current density of 2.75 A / mm 2, window
space factor 0.32; volt / turn = 16.8; use cruciform core section, height of the
window is 3 times its width. Also find number of turns and cross sectional
area of primary and secondary winding.
28. June / July 2011 : 8 Marks
Calculate the no load current for 11000 / 400 V, 50 Hz, single phase core type
transformer. If mean length of magnetic path is 300 cm, gross iron area of the
core is 150 cm2, maximum flux density is 1.2 T, core loss / kg of iron is 3.3 W,
AT/m of the transformer iron is 800; density of iron is 7.5 g /c.c, stacking
factor 0.95, and joints are equivalent 0.1 mm of air gap.
29. Dec 2010 : 10 Marks
A 100 KVA, 2000 / 400 V, 50 Hz. Single phase shell type transformer has the
following particulars: maximum flux density 1.1 T; current density 2.2 X 10 6
A / m2; window space factor 0.30; ratio of depth of stacked core to width of
central limb 2.6; ratio of height to width of window 2.5; stacking factor 0.90
Question Bank
-574240, INDIA
2015-16 :
PART - B
UNIT 5 & 6 : Design of Induction Motors
1.
Dec 2014 / Jan 2015 : 05 Marks, June 2012: 10 Marks, Dec2013 / Jan 2014 : 08
Marks, June/July 2011: 10 Marks, May/June10: 05 Marks, Jan / Feb06: 10Marks,
Dec 2015 / Jan 2016 : 04 Marks, June / July 2014 : 10 Marks, June / July 2015 :
10 Marks
Discus the various factors considered when estimating length of air gap of a
3-phase induction motor. Give the expression used in calculations of length of
air gap.
Or
Explain the factors which influence the length of air gap of 3phase induction
motor & write few empherical formulae for the length of air gap.
Or
Mention the factors that are affected by the length of the air gap in 3phase
induction motors. List the advantages & disadvantages of larger air gap in
3phase induction motors.
Or
Discuss the various factors that influence the choice of length of the air gap of
an induction motor.
2.
Question Bank
-574240, INDIA
2015-16 :
3.
4.
5.
6.
7.
8.
9.
Question Bank
-574240, INDIA
2015-16 :
D 0.135 P L
operation
24. June / July 2014 : 12 Marks
During the design of 3-phase, 5KW,400V,50Hz,4 pole squirrel cage induction
motor designed for star-delta starting, following data have been obtained:
Rotor diameter = 0.14m, Core length = 0.11m,turns per phase on stator =
360,air gap length = 0.45mm, Coaters gap contraction coefficient = 1.25,
Assuming that the ampere turns required for the iron parts are about 32% of
that needs for the gap, calculate the magnetizing current drawn by the motor
& comment, upon its value.
Assume winding factor, Kw = 0.955, efficient = 85% & p.f = 0.85
25. Dec2013 / Jan 2014 : 08 Marks, A 1.1 kW,3phase,50Hz 1500rpm delta
connected induction motor has stator bore D = 0.15m & core length L =
0.06m. Estimate the main dimensions of a 3.7kW,3phase 50Hz,1000rpm delta
connected motor having the same loadings as the previous one. The efficiency
& power factor are also same. Assume the same L/ ratio.
26. Dec2013 / Jan 2014 : 12 Marks
Estimate the stator core dimensions, number of stator slots & number of
stator conductor per slot for a 100KW,3300V,50Hz,12pole star connected slip
ring induction motor Assume: average gap density = 0.4wb/m 2; ampere
conductors/m = 25000; efficiency = 0.9, power factor = 0.9. The slot loading
should not exceed 500 ampere conductors.
Question Bank
-574240, INDIA
2015-16 :
Question Bank
-574240, INDIA
2015-16 :
2015-16 :
Question Bank
-574240, INDIA
2015-16 :
2.
3.
4.
5.
Dec 2014 / Jan 2015: 06Marks, Dec 2015 / Jan 2016 : 05 Marks,
Dec2013/Jan2014 : 10marks,June/ july2011 : 06Marks, Dec 2011:06marks, Jun /
July2009 :10marks
Discuss any five factors to be considered in selection of no. of slots in
synchronous machines.
Or
Explain the factor to be considered while selecting suitable no. of armature
slots in synchronous machine.
Or
What are the factors that effect selection of armature slots?
6.
June / July 2014 ,2013: 08Marks, 10Marks, June / July 2013: 08Marks, 10Marks,
June/July 2011: 10 Marks, Dec 2015 / Jan 2016 : 05 Marks, Dec2010 : 10marks,
June / July 2015 : 10 Marks
From the first principles, derive output equation 3phase alternator in terms of
specific loadings, diameter & length of the stator core. What are the usual
values of specific loadings?
Or
Question Bank
-574240, INDIA
2015-16 :
8.
9.
June / July 2014 : 06Marks, Dec 2011 : 08marks, Jun / July 2011: 06marks
Enumerate the advantages & disadvantages of providing a large air gap in
synchronous machines.
Question Bank
-574240, INDIA
2015-16 :
/ phase and size of armature conductors: Given Average gap density = 0.6 T,
Ampere Conductors / meter = 50000, Peripheral Speed = 180 m / s, Winding
factor = 0.95, Current density = 6 A / mm2
18. Dec2013/Jan2014 : 10marks
Find the main dimension of a 2500 KVA; 187.5 rpm 50Hz; 3phase salient pole
synchronous generator. The generator is to be vertical wheel type. Specific
magnetic loading is 0.6Wb/m2 and specific loading is 34000 ac/m. Use circular
poles ratio of core length to the pole pitch = 0.65 Specify the type of pole
construction used if the runaway speed is about two times the normal speed.
Assume Kw = 0.955
19. June / July2013: 10marks
Obtain the suitable values of diameter & core length for a 1500
kVA,3300V,3phase delta connected, 10pole alternator which has specific
magnetic loading 0.51 T & specific electric loading 34,000 A/m. The pole pitch
to core length is 0.8. Assume winding factor as 0.955, frequency 50Hz
20. Dec 2012: 14marks.
For the preliminary design of a 1250 KVA,3.3 KV 50
Hz, 300rpm 3phase star connected salient pole alternator. Determine the
dimension of the stator slot. Also sketch the slot showing the arrangement of
conductors & insulation details. Assume specific magnetic loading = 0.58 T,
specific electric loading = 330AC/cm, core length = 1.1 x (pole pitch) , field
form factor = 0.66, stacking factor = 0.96, current density = 4A/mm 2,
maximum flux density in the teeth is limited 1.8 T, winding type = full pitched
with 60 phase spread/slot/pole/phase = 3, slot loading should not exceed
1500 A, no. of ventilating ducts = 4, width of ventilating ducts = 1cm
21. Dec 2011: 12 Marks. Determine for a 500 KVA, 6600V, 12 poles, 500 rpm, 3
phase alternator, suitable values for (1) the diameter at air gap (II) the core
length (iii) the number of stator conductors (iv) the number of stator slots.
Assume a stator connected stator winding a specific magnetic loading of
0.6Wb/m2 & specific electeic loading of 30,000AC/m. Assume ratio length :
pole pitch = 1.5
22. Dec 2011:08marks.
A 500 kVA, 3.3KV, 50Hz, 600 rpm, 3 phase salient pole alternator has
180turns/phase. Estimate the length of air gap if the average flux density =
0.575 Wb/m2; pole arc/pole pitch = 0.66; short circuit ratio = 1.2; gap
contraction factor = 1.15. The mmf required for the gap is 82% of the no load
field mmf. KW = 0.955.
23. JuneJuly2011:10 Marks, June / July 2015 : 10 Marks
During the design of stator for a 3phase, 7.5KVA, 6.6KV, 50Hz,3000rpm turbo
alternator, following information have been obtained. Internal diameter of
stator = 0.75m, Gross core length = 0.9m, No. of stator/slots/pole/phase = 7,
Sectional area of stator conductor = 190mm2, No. of conductors per slot = 4.
Based on above data calculate
i) Flux/pole ii)Specific loading iii) Current density for stator winding
24. JuneJuly2011:08marks
Find the main dimensions of a 100MVA, 11KV, 50Hz, 150rpm, 3phase water
generators. Given Bav = 0.65Wb/m2; ac/m = 40000. The peripheral speed
should not exceed 65 m/sec at normal running sped in order to limit the
runway speed. Assume Kw = 0.95
25. Dec2010 : 10marks
Determine the suitable no. of slots & conductors/slot, for the stator winding of
Question Bank
-574240, INDIA
2015-16 :
a 3phase 3300V, 50Hz, 300rpm alternator. The diameter is 230 cm & axial
length of core is 35cm, the maximum flux density in air gap should be
approximately 0.9wb/m2. Assume the sinusoidal flux distribution. Use single
layer winding & star connection for stator.
26. Dec2010 : 12marks
The following is the design data available for a 1250 KVA, 3phase 50Hz,
3300V,star connected, 300rpm alternator of salient pole type. Stator bore D
=1.9m, stator bore length, L = 0.335mt, pole arc/pole pitch = 0.66,
turns/phase = 150, single layer concentric winding with 5 conductors per slot,
short circuit ratio = 1.2. Assume that the distribution of gap flux is
rectangular region. Calculate :
i) Specific magnetic loading ii)Armature mmf per pole iii)Gap density over pole
arc iv)Air gap length
mmf required for air gap is 0.88 of No-load field mmf & the gap contraction
factor is 1.15.
27. Dec09/Jan10 :10marks
Find the main dimensions of a 100 MVA, 11KV, 50Hz, 150 rpm, 3phase water
wheel generator. Given that
Bav = 0.65wb/m2 & ac/m are 40000. The peripheral speed should not exceed
65m/s at normal running speed in order to runway speed.
28. Mayjun2010 :10marks
For a 125 MVA, 6.6kV,50Hz 3phase, 3000rpm star connected turbo alternator,
calculate bore diameter, core length, no. of slots & turns per phase using the
following data :
Average flux density in the air gap = 0.55wb/m2, Ampere conductors/m =
57,000, Length of air gap = 3cms, peripheral velocity <150m/sec.
29. Junjuly2009 :10marks
A 15kW, 420V, 3phase alternator has 180 slots with 5 conductors/slot. Single
layer winding with full pitched coils are used. The winding is star connected
with one circuit per phase. The stator bore diameter is 0.2m & the core length
is 0.4m. The winding is having a 60 degree phase spread, with full pitched
coils.
30. Junjuly2009 :10marks
The following particulars refer to a 1250KVA, 3phase, 3300V, 50Hz star
connected alternator running at 300rpm. Stator bore diameter = 1900cms,
core length = 33.5cms, no. of ventilating ducts = 4 with 1cm width each,
number slots = 180, size of slots = 13.5mm53mm, air gap flux density =
0.576wb/m2. Ampere conductors per cm of periphery = 331. Calculate i) Flux
density in stator teeth ii)Cross section of the conductor iii)No. of conductors
per slots.
31. Dec07/Jan08 :12Marks
Obtain the main dimensions of a 500KVA , 6600V 50Hz, 12pole star connected
salient pole alternator giving the following details. I) Internal diameter ii)
Length of the machine No. of conductors/phase.
B = 0.56T, specific electric loading = 26,000 AC/meter winding factor = 0.96
32. Jan / Feb 06 :10Marks
Find the main dimensions of a 2500KVA, 187.5 rpm 50Hz, 3phase, salient pole
synchronous generator. The generator is to be vertical water wheel type. The
specific magnetic loading is 34,000 AC/m, use circular poles with ratio of core
length to pole pitch = 0.65. Specify the type of pole construction used if the
runaway speed is about two times the normal speed.
33. Dec2015/Jan2016 : 12 Marks
Question Bank
-574240, INDIA
2015-16 :
The field coils of a salient pole alternator are wound with a single layer
winding of bare copper strip of 30 mm deep, with separating insulation of
0.15 mm thick. Determine a suitable winding length, number of turns and
thickness of conductors to develop an mmf of 1200 AT with potential
difference of 5 Volts per coil and with a loss of 1200 W / m 2 of total coil
surface. The mean length of turn is 1.2 m and resistivity of copper is 0.021 /
m / mm2
34. June / July 2015 : 10 Marks.
Design the field coil of a 3 phase, 16 poles,
50 Hz, salient pole alternator, based on the following design information:
Diameter of stator at the gap surface = 1.0 m, gross length of stator core =
0.3 m, section of the pole body = 0.5 m x 0.3 m, height of pole = 0.15 m,
ampere turns per pole = 6500, exciter voltage = 110 V, Assume 30 volts as
reserve; depth of filed coil = 0.03 m, insulation of pole = 0.01 m, current
density = 2.6 A / mm2.
Question Bank
-574240, INDIA
2015-16 :