0% found this document useful (0 votes)
178 views4 pages

Tower Configuration Data

This document contains technical specifications for a 500kV overhead transmission line, including: 1. The line is 50.43 km long with 6 conductors in a transposed configuration. 2. Technical details are provided for the aluminum conductor steel-reinforced conductors and overhead ground wire. 3. A tower type is specified that is 42m high with cross arms at varying heights for the 6 conductors.

Uploaded by

Ratana Kem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views4 pages

Tower Configuration Data

This document contains technical specifications for a 500kV overhead transmission line, including: 1. The line is 50.43 km long with 6 conductors in a transposed configuration. 2. Technical details are provided for the aluminum conductor steel-reinforced conductors and overhead ground wire. 3. A tower type is specified that is 42m high with cross arms at varying heights for the 6 conductors.

Uploaded by

Ratana Kem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

Model

Overhead Line
phase
transposed
Auto bundling
skin effect
segmented ground
real transf. matrix
Unit
Model type
Ground Resist. Ohm/m
Freq. initial [Hz]
Length [km]

500kV Transmission Line Data


1 Line length (km)
2 Phase conductor
ACSR =
bundle separation =
Rdc =
Rin =
Rout =
line sag at the middle =
3 Overhead Ground wire (OHGW)
OGW =
Rdc =
Rout =
ogw sag at the middle =
4 Tower Type
Tower High =
Cross arm ph-a =
Cross arm ph-b =
Cross arm ph-c =
high Cr-arm ph-a =
high Cr-arm ph-b =
high Cr-arm ph-c =
Cross-Arm length =
Length insulation string =
V-String suspension H =
V-String suspension V =

Data (double Circuit 230kV)


yes
6
yes
yes
yes
yes
no
meter
Bergeron
100
50
50.43

No.

Ph. No

Rin
[cm]

1
2
3
4
5
6
7
8

1
2
3
0
0
4
5
6

0.5181
0.5181
0.5181
0
0.6
0.5181
0.5181
0.5181

Note *** : this tower configuration 230kV is mostly used by EDC

50.43

km

954
0
0.0717
0.5181
1.4065
13

MCM
cm
ohm/km
cm
cm
m

AGW
inch
1.892
ohm/km
6.450
cm
10.4
m
DA1
42.00
10
11
12
26
32
38
42
2.336

Rout
[cm]
1.4065
1.4065
1.4065
6.45
1.34
1.4065
1.4065
1.4065

Resis
[ohm/km DC]

Horiz
[m]

Vtower
[m]

Vmid
[m]

0.0717
0.0717
0.0717
1.892
2.236
0.0717
0.0717
0.0717

-5
-5.5
-6
-5.5
5.5
5
5.5
6

38
32
26
42
42
38
32
26

25
19
13
31.6
31.6
25
19
13

ation 230kV is mostly used by EDC's projects

Separ
[cm]

Alpha
[deg]

NB

Sag
[m]
13
13
13
10.4
10.4
13
13
13