Reinforcement Calculations For Nozzle "C2": Area Required Per UG-37 (C)
Reinforcement Calculations For Nozzle "C2": Area Required Per UG-37 (C)
Reinforcement Calculations For Nozzle "C2": Area Required Per UG-37 (C)
=
=
5.661 in2
=
=
=
=
=
0.197 in2
in2
0.4006
Design thickness for Internal Pressure of 550 psi
=
=
=
0.5358
in
45.75 / 18
2.5417
Do / t
18 / 0.2147
83.83791
0.000654
9429.904 psi
From table
A
G:
From table
B
CS-2:
Pa
=
=
=
=
t + Corrosion
=
0.2147 + 0.25
0.4647 in
The required thickness (trn) is the maximum of internal and external pressure, i.e. 0.5358 in
5*(tn' - trn)*fr2*t
5*(0.75 - 0.5358)*0.855*0.4375
in2
0.4006
=
=
0.9157
=
=
ti=
fr2=
t=
h=
0.75-0.25
0.5
0.855
0.4375
6
=
=
5*t*ti*fr2
=
=
5*ti*ti*fr2
2*h*ti*fr2
5.1300
0.9352
1.0688
in2
0.935156 in2
in
in
in
in2
in2
in2
A41
=
=
=
Leg2*fr3
=
=
Leg2*fr4
0.1406
=
=
=
Leg2*fr2
=
=
(Dp - d - 2*tn)*te*fr4
(40.42 - 20.24-2*0.562)*0.625*1
11.9100
Total Area =
Available
14.6559
A42
A43
A5
0.375 *0.855
in2
0.1202
2
0.375 *1
2
in2
from 150 psi design
0.375 *0.855
in2
0.1202
2
in2
>