Reinforcement Calculations For Nozzle "C2": Area Required Per UG-37 (C)

The reinforcement calculations are performed for nozzle C2 based on allowable stresses and design requirements. The required reinforcement area is 5.661 in^2 based on an internal pressure of 150 psi. Several area calculations are shown for internal pressure of 550 psi, external pressure of 150 psi, and other design conditions. The total calculated area of 14.6559 in^2 is greater than the required area.

Uploaded by

Bashu Poudel
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
115 views

Reinforcement Calculations For Nozzle "C2": Area Required Per UG-37 (C)

The reinforcement calculations are performed for nozzle C2 based on allowable stresses and design requirements. The required reinforcement area is 5.661 in^2 based on an internal pressure of 150 psi. Several area calculations are shown for internal pressure of 550 psi, external pressure of 150 psi, and other design conditions. The total calculated area of 14.6559 in^2 is greater than the required area.

Uploaded by

Bashu Poudel
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

Reinforcement Calculations for Nozzle "C2"

Area required per UG-37(c)


Allowable stresses: Sn = 17,100, Sv = 20,000, Sp = 20,000 psi
fr1 = lesser of 1 or Sn / Sv = 0.855
fr2 = lesser of 1 or Sn / Sv = 0.855
fr3 = lesser of fr2 or Sp / Sv = 0.855
fr4 = lesser of 1 or Sp / Sv = 1
A

=
=

d*tr*F + 2*tn*tr*F*(1 - fr1)


17.3599*0.3234*1 + 2*0.5*0.3234*1*(1 - 0.855)

from 150 psi design

5.661 in2

Area available from FIG. UG-37.1


1.964 in2

A1 = larger of the following=

from 150 psi design

=
=
=

d*(E1*t - F*tr) - 2*tn*(E1*t - F*tr)*(1 - fr1)


17.3599*(1*0.4375 - 1*0.3234) - 2*0.5*(1*0.4375 - 1*0.3234)*(1 - 0.855)
1.964 in2

=
=

2*(t + tn)*(E1*t - F*tr) - 2*tn*(E1*t - F*tr)*(1 - fr1)


2*(0.4375 + 0.5)*(1*0.4375 - 1*0.3234) - 2*0.5*(1*0.4375 - 1*0.3234)*(1 - 0.855)

0.197 in2

in2
0.4006
Design thickness for Internal Pressure of 550 psi

A2 = smaller of the following=


t

=
=
=

from 550 psi design

P*Ro / (S*E + 0.40*P) + Corrosion


550*9 / (17,100*1.00 + 0.40*550) + 0.25

0.5358

in

External Pressure, (Corroded & at 150 F) UG-28(c)


L / Do

45.75 / 18

2.5417

Do / t

18 / 0.2147

83.83791

0.000654

9429.904 psi

From table
A
G:
From table
B
CS-2:
Pa

=
=
=

4*B / (3*(Do / t))


4*9429.9 / (3*(18 / 0.2147))
150 psi

Design thickness for external pressure Pa = 150 psi


ta

=
t + Corrosion
=
0.2147 + 0.25
0.4647 in
The required thickness (trn) is the maximum of internal and external pressure, i.e. 0.5358 in

5*(tn' - trn)*fr2*t
5*(0.75 - 0.5358)*0.855*0.4375
in2
0.4006

=
=

2*(tn' - trn)*(2.5*tn' + te)*fr2


2*(0.75 - 0.5358)*(2.5*0.75 + 0.625)*0.855

0.9157

=
=

A3 = smaller of the following =

ti=
fr2=
t=
h=

0.75-0.25
0.5
0.855
0.4375
6

=
=

5*t*ti*fr2

=
=

5*ti*ti*fr2

2*h*ti*fr2

5.1300

0.9352

1.0688

in2
0.935156 in2

(NOT INCLUDED IN TOTAL AREA)


from 550 psi design

in
in
in

in2

in2

in2

A41

=
=
=

Leg2*fr3

=
=

Leg2*fr4

0.1406

=
=
=

Leg2*fr2

=
=

(Dp - d - 2*tn)*te*fr4
(40.42 - 20.24-2*0.562)*0.625*1

11.9100

Total Area =
Available

14.6559

A42

A43

A5

from 150 psi design

0.375 *0.855
in2
0.1202
2

from 150 psi design

0.375 *1
2

in2
from 150 psi design

0.375 *0.855
in2
0.1202
2

in2

>

Area Required (5.661 in2)