Reinforcement Calculations For Nozzle "C2": Area Required Per UG-37 (C)

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 3

Reinforcement Calculations for Nozzle "C2"

Area required per UG-37(c)


Allowable stresses: Sn = 17,100, Sv = 20,000, Sp = 20,000 psi
fr1 = lesser of 1 or Sn / Sv = 0.855
fr2 = lesser of 1 or Sn / Sv = 0.855
fr3 = lesser of fr2 or Sp / Sv = 0.855
fr4 = lesser of 1 or Sp / Sv = 1
A

=
=

d*tr*F + 2*tn*tr*F*(1 - fr1)


17.3599*0.3234*1 + 2*0.5*0.3234*1*(1 - 0.855)

from 150 psi design

5.661 in2

Area available from FIG. UG-37.1


1.964 in2

A1 = larger of the following=

from 150 psi design

=
=
=

d*(E1*t - F*tr) - 2*tn*(E1*t - F*tr)*(1 - fr1)


17.3599*(1*0.4375 - 1*0.3234) - 2*0.5*(1*0.4375 - 1*0.3234)*(1 - 0.855)
1.964 in2

=
=

2*(t + tn)*(E1*t - F*tr) - 2*tn*(E1*t - F*tr)*(1 - fr1)


2*(0.4375 + 0.5)*(1*0.4375 - 1*0.3234) - 2*0.5*(1*0.4375 - 1*0.3234)*(1 - 0.855)

0.197 in2

in2
0.4006
Design thickness for Internal Pressure of 550 psi

A2 = smaller of the following=


t

=
=
=

from 550 psi design

P*Ro / (S*E + 0.40*P) + Corrosion


550*9 / (17,100*1.00 + 0.40*550) + 0.25

0.5358

in

External Pressure, (Corroded & at 150 F) UG-28(c)


L / Do

45.75 / 18

2.5417

Do / t

18 / 0.2147

83.83791

0.000654

9429.904 psi

From table
A
G:
From table
B
CS-2:
Pa

=
=
=

4*B / (3*(Do / t))


4*9429.9 / (3*(18 / 0.2147))
150 psi

Design thickness for external pressure Pa = 150 psi


ta

=
t + Corrosion
=
0.2147 + 0.25
0.4647 in
The required thickness (trn) is the maximum of internal and external pressure, i.e. 0.5358 in

5*(tn' - trn)*fr2*t
5*(0.75 - 0.5358)*0.855*0.4375
in2
0.4006

=
=

2*(tn' - trn)*(2.5*tn' + te)*fr2


2*(0.75 - 0.5358)*(2.5*0.75 + 0.625)*0.855

0.9157

=
=

A3 = smaller of the following =

ti=
fr2=
t=
h=

0.75-0.25
0.5
0.855
0.4375
6

=
=

5*t*ti*fr2

=
=

5*ti*ti*fr2

2*h*ti*fr2

5.1300

0.9352

1.0688

in2
0.935156 in2

(NOT INCLUDED IN TOTAL AREA)


from 550 psi design

in
in
in

in2

in2

in2

A41

=
=
=

Leg2*fr3

=
=

Leg2*fr4

0.1406

=
=
=

Leg2*fr2

=
=

(Dp - d - 2*tn)*te*fr4
(40.42 - 20.24-2*0.562)*0.625*1

11.9100

Total Area =
Available

14.6559

A42

A43

A5

from 150 psi design

0.375 *0.855
in2
0.1202
2

from 150 psi design

0.375 *1
2

in2
from 150 psi design

0.375 *0.855
in2
0.1202
2

in2

>

Area Required (5.661 in2)

from 150 psi design