Appendix-2 Seismic "G" Load Calculation

This document provides the calculation of the seismic "g" load factor for stress analysis of components at the Badra Oilfield in Iraq. It involves inputting parameters like soil profile type, seismic zone factor, seismic source information, amplification factors, and component properties. The output is the total design lateral seismic force and checking that it meets required minimum and maximum criteria according to building code standards. The calculated seismic "g" load factor is 0.34g.

Uploaded by

kemo10
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
128 views2 pages

Appendix-2 Seismic "G" Load Calculation

This document provides the calculation of the seismic "g" load factor for stress analysis of components at the Badra Oilfield in Iraq. It involves inputting parameters like soil profile type, seismic zone factor, seismic source information, amplification factors, and component properties. The output is the total design lateral seismic force and checking that it meets required minimum and maximum criteria according to building code standards. The calculated seismic "g" load factor is 0.34g.

Uploaded by

kemo10
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

EPC CPF PHASE 2 AT BADRA OILFIELD, IRAQ

SPECIFICATION FOR STRESS ANALYSIS


Doc No.: GB090-2614-250-PI-SP-0003

Rev. : 1

Page : 31 of 38

APPENDIX- 2 SEISMIC g LOAD CALCULATION


Seismic g load factor calculation defines the acceleration factor to be applied on the
stress system. It is calculated as per 1997 Uniform Building Code.
INPUT
1) GEOMETRICAL INPUT
Soil Profile Type

Sc

Seismic Zone Factor, Z

0.3

Seismic Source Type (If Z=0.4)


Distance from Source, Km (If Z=0.4)
Seismic Coefficient, Ca

0.33

2) OTHER PARAMETERS
In Structure Component
Amplification Factor (ap) (As per

UBC-97, Table 16-O, Item 3.B)


Seismic Importance Factor (Ip)
(As per UBC-97, Table 16-K, SI no.4)

1.25

Component Response Modification


Factor (Rp)

(UBC-97, Table 16-O, Item 3.B)


Element or Component Attachment
Elevation with respect to Grade (hx)
/ Structure roof Elevation with

0.5

respect to Grade (hr)


TO CONSIDER THE EFFECT OF PLANT PIPING PASSING THROUGH VARIOUS
ELEVATION hx/hr IS CONSIDERED AS 0.5

EPC CPF PHASE 2 AT BADRA OILFIELD, IRAQ


SPECIFICATION FOR STRESS ANALYSIS
Doc No.: GB090-2614-250-PI-SP-0003

Rev. : 1

Page : 32 of 38

OUTPUT
Total Design Lateral Seismic Force Fp
(as per UBC-97, Volume-2, Section
1632,Equation 32-2)

Fp=ap x Ca x Ip/Rp x
{ 1 + 3 x hx/hr } x Wp

W
0.34

0.3

=
p

Checking of Section 1632 Equation 32-3:


a) Fp >= 0.7 x Ca x Ip x Wp
b) Fp <= 4 x Ca x Ip x Wp
a) Fp >= 0.7 x Ca x Ip x Wp
b) Fp <= 4 x Ca x Ip x Wp

0.7 x Ca x Ip x Wp

0.29 Wp =

4 x C a x I p x Wp

1.65 Wp =

Seismic "g" Load Factor for Input in Stress Analysis Calculations

0.34 g

0.2
9
1.6
5

m
g
m
g