0% found this document useful (0 votes)
263 views2 pages

International Well Control Forum Subsea BOP Kill Sheet - Vertical Well (Metric/Bar)

This document is a kill sheet for a vertical subsea well. It provides data on the current well including formation strength from a test, casing shoe depth, drilling fluid properties, and hole size. It also lists equipment specifications like BOP and riser details. Volume calculations are shown for the drill string, open hole, casing, choke line, and total active system. The kick details section outlines initial and final circulating pressures needed to kill the well based on shut-in drill pipe pressure, casing pressure, and pump rate calculations. The sheet is designed to help operators safely kill a well after a kick occurs subsea.

Uploaded by

ahmedhussien1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
263 views2 pages

International Well Control Forum Subsea BOP Kill Sheet - Vertical Well (Metric/Bar)

This document is a kill sheet for a vertical subsea well. It provides data on the current well including formation strength from a test, casing shoe depth, drilling fluid properties, and hole size. It also lists equipment specifications like BOP and riser details. Volume calculations are shown for the drill string, open hole, casing, choke line, and total active system. The kick details section outlines initial and final circulating pressures needed to kill the well based on shut-in drill pipe pressure, casing pressure, and pump rate calculations. The sheet is designed to help operators safely kill a well after a kick occurs subsea.

Uploaded by

ahmedhussien1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PAGE 1 OF 2

International Well Control Forum

DATE :

Subsea BOP Kill Sheet - Vertical Well (Metric/Bar)

NAME :

CURRENT WELL DATA:

FORMATION STRENGTH DATA:


SURFACE LEAK -OFF PRESSURE FROM
(A)
FORMATION STRENGTH TEST

bar

SUBSEA BOP DATA:

(B)

kg/l

MARINE RISER
LENGTH

CHOKELINE
LENGTH

DRILLING FLUID DENS. AT TEST

MAX. ALLOWABLE DRILLING FLUID DENSITY =


(A) x 10.2
(B) +
= (C)
SHOE T.V. DEPTH

kg/l

INITIAL MAASP =
((C) - Current Density) x Shoe TVD
10.2

PUMP NO. 1 DISPL.

DRILLING FLUID:
DENSITY

bar

CASING SHOE DATA:

PUMP NO. 2 DISPL.


l / stroke

l / stroke

(PL) DYNAMIC PRESSURE LOSS [bar]


SLOW PUMP
RATE DATA:

PUMP NO. 1
Riser Choke Choke
Line
Line

PUMP NO. 2
Riser Choke Choke
Line
Line
Friction

Friction

SPM
SPM
PRE-RECORDED
VOLUME DATA:

LENGTH
m

DRILL PIPE

kg/l

CAPACITY
l/m
x

SIZE

in

M. DEPTH

T.V. DEPTH

HOLE DATA:
SIZE

in

M. DEPTH

T.V. DEPTH

VOLUME
litres

PUMP STROKES
stks

TIME
minutes

VOLUME

HEVI WALL DRILL PIPE

DRILL COLLAR

+
(D)

DRILL STRING VOLUME


DC x OPEN HOLE

DP / HWDP x OPEN HOLE

OPEN HOLE VOLUME

PUMP DISPLACEMENT

(E)

stks

min

+
(F)

stks

min

DP x CASING

= (G)

stks

min

CHOKELINE

= (H)

stks

min

TOTAL ANNULUS/CHOKELINE VOLUME

(F+G+H) = (I)

stks

min

TOTAL WELL SYSTEM VOLUME

(D+I) = (J)

stks

min

ACTIVE SURFACE VOLUME

(K)

stks

TOTAL ACTIVE FLUID SYSTEM

(J+K)

stks

stks

MARINE RISER x DP

Dr No SSV 01/01
(BAR-102)
27-01-2000

PAGE 2 OF 2

International Well Control Forum

DATE :

Subsea BOP Kill Sheet - Vertical Well (Metric/Bar)

NAME :

KICK DATA :
SIDPP
KILL FLUID DENSITY

bar

SICP

bar

CURRENT DRILLING FLUID DENSITY


.................

KMD
INITIAL CIRCULATING
PRESSURE

PIT GAIN

litres

SIDPP x 10.2

TVD

kg / l

DYNAMIC PRESSURE LOSS + SIDPP


................. + ................. =
bar

ICP
KILL FLUID DENSITY

FINAL CIRCULATING

CURRENT DRILLING FLUID DENSITY

PRESSURE
FCP

x DYNAMIC PRESSURE LOSS

x ................. =

(L) = ICP - FCP = ............ - ............ = ........... bar


INITIAL DYNAMIC CASING PRESSURE
AT KILL PUMP RATE

bar

(L) x 100
(E)

SICP - CHOKE LINE FRICTION

X 100

.................... -

bar

.....................

100 strokes
=

bar

STROKES PRESSURE

STATIC & DYNAMIC DRILL PIPE PRESSURE [bar]

[bar]

STROKES
Dr No SSV 01/02 (BAR-102) 27-01-2000