100% found this document useful (1 vote)
165 views3 pages

ETABS Tutorial Example Acecoms, Ait

This document provides details for modeling and analyzing a 10-story reinforced concrete building in ETABS, including section properties of building elements, story heights, static load cases for dead and live loads, wind load cases, equivalent lateral force analysis parameters based on IBC2000, and equivalent static force cases for seismic loading. Beam and column dimensions, slab and shear wall thicknesses, load values, and analysis parameters such as time period, response modification factor, and seismic design coefficients are specified.

Uploaded by

ronaldcatequista
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
165 views3 pages

ETABS Tutorial Example Acecoms, Ait

This document provides details for modeling and analyzing a 10-story reinforced concrete building in ETABS, including section properties of building elements, story heights, static load cases for dead and live loads, wind load cases, equivalent lateral force analysis parameters based on IBC2000, and equivalent static force cases for seismic loading. Beam and column dimensions, slab and shear wall thicknesses, load values, and analysis parameters such as time period, response modification factor, and seismic design coefficients are specified.

Uploaded by

ronaldcatequista
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ETABS Tutorial Example

ACECOMS, AIT

Section Properties
Member

Dimension

Beam (width x Height)

30 x 60 cm

Column

50 x 50 cm

Slab

Thickness = 15 cm

Shear wall

Thickness = 20 cm

Story Height Data


Story

Height

Typical Story

3.00 m

Story at base of building

4.00 m

Static Load Cases


Load
Name

DEAD

LIVE

8/97

Load Type

Dead Load

Reducible
Live Load

Details

Value

Self Weight of Structural Members


Calculate automatically using Self
Weight Multiplier in ETABS

Uniform Load on Slabs:


(Finishing + Partition Load)

0.20 t/m2

Uniform Load on Beams:


(Wall Load)

0.50 t/m

Uniform Load on Slabs:


(Use Tributary Area: UBC97)

0.25 t/m2

Seismic Analysis & Design of 10 Story RC Building (Equivalent Lateral Force)

ETABS Tutorial Example

ACECOMS, AIT

Wind Load Cases (UBC97)


Load Case
Parameter

Wind Direction

WINDX

WINDY

Wind Speed

90 mph

Exposure Type

B (Suburban area)

Importance Factor

1 (Building normal importance)

Equivalent Static Force Parameters (IBC2000)


Parameter

Values

Remark

Time Period (T)

1.47

Equation 16-39
(Ct = 0.020)

Response Modification
Factor (R)

5.5

Table 1617.6
(Dual System: Ordinary RC
Shear Wall)

Seismic Group

Section 1616.2

Site Class

Table 1615.1.1
(Soft Clay)

Response Acceleration
at Short Period (Ss)

0.45

Response Acceleration
at 1 Second (S1)

0.18

Seismic Analysis & Design of 10 Story RC Building (Equivalent Lateral Force)

9/97

ETABS Tutorial Example

ACECOMS, AIT

Equivalent Static Force Case

10/97

Load Case Name

Direction and
Eccentricity

% Eccentricity

EQXA

X Dir + Eccen. Y

0.05

EQXB

X Dir - Eccen. Y

0.05

EQYA

Y Dir + Eccen. X

0.05

EQYB

Y Dir - Eccen. X

0.05

Seismic Analysis & Design of 10 Story RC Building (Equivalent Lateral Force)