Allweiler Screw Pumps

Download as pdf or txt
Download as pdf or txt
You are on page 1of 44

ALLWEILER

Screw Pumps
Series SN

Application
For handling lubricating fluids. The fluids to be pumped must
not contain any abrasive substances nor chemically attack the
pump materials.
Main fields of application
Fuel oil firing/energy engineering:
For handling light and heavy fuel oils as well as residual and
waste oils, e.g. as fuel oil, transfer, fuelling, ring-conduit and
burner-operation pumps.
Hydraulics:
For booster and/or pumping hydraulic oils on mineral-oil basis
or hydraulic lubricating liquids; e.g. as hydraulic pumps for lifts,
elevating platforms, pusher centrifuges, hydraulic presses,
forging hammers, bale presses, chip-board presses, winches,
hoists, variable-pitch propeller and rudder adjusting units,
hatch hydraulics, rolling mill and machine tool hydraulics.
General industrial engineering/machine/heavy machine industry:
For handling lubricating, cooling, coolant, sealing, regulating
and hydraulic oils, light and heavy fuel oils, Diesel oils, fuels and
thermal oils (cold), e.g. for steam, gas and water turbines as
lubricating, sealing, regulating oil and jacking oil pumps, for
compressors as lubricating, sealing and coolant oil pumps, for
gear drives as lube-oil pumps, for Diesel engines as lubricating
and cooling oil as well as fuel pumps, for rolling milis as lube-oil
and hydraulic pumps etc.
Marine/Offshore engineering:
For handling lubricating, cooling and hydraulic oils, light and
heavy fuel oils, crude oils as well as fuels.
Machine-tool industry:
For handling cutting, grinding, deep-hole drilling oils and oilin-water emulsions as well as hydraulic oils.
Tank farms:
For handling all lubricating fluids such as greases, oils, paints,
fuels, polyols, isocyanates; e.g. as loading or unloading pumps.
Printing industry:
For handling gravure inks.
Chemical and petro-chemical as well as processing industry:
For handling all lubricating fluids such as oils (including crude
oils), greases, paint, lacquers, ointments, pastes, polyols, isocyanates, tar, bitumen, glycerin, glues, adhesive substances,
resins, paraffins, waxes, water glass and also as pipeline
pumps.
Paint/lacquer industry:
For handling paints, lacquers, resins, oil varnish and linseed oils.
Washing/cleansing agent industry:
For handling oils, greases, soaps and additives.
Paper/pulp industry:
For handling viscose and pulp.
Food industry:
For handling molasses, glucose, sirup and vegetable oils.

Design
Self-priming three-screw pump.
The hardened and ground spindles run in a replaceable casing
insert.
The axial thrust acting on the flanks of the screw threads is compensated by balance pistons which - with all three spindles are arranged in the delivery chamber.
The idler spindles are turned hydraulically. The thread flanks
merely transmit the torque resulting from the liquid friction and
are consequently practically free of stress and nt subject to
any wear.
A groove ball bearing lubricated by the fluid to be pumped (with
internal bearing design) respectively an external, grease lubricated groove ball bearing serves for fixing the driving spindle.
A stuffing box or two shaft sealing rings or a maintenance-free
unbalanced mechanical seal as required is used as shaft sealing. By means of a return pipe, the sealing chamber is connected with the suction chamber. Therefore, irrespectively of the
delivery pressure, only the suction/inlet pressure always becomes effective at the shaft sealing.

Function
Owing to a special profiling of the flanks of the screw threads,
the three spindles form sealed chambers, the contents of which
are axially and completely continuously shifted from the suction to the delivery side of the pump. There is no turbulence
despite the rotational movement, and squeezing stresses are
avoided by the constant volume in the chambers.

Noise/pulsation
The structural design and mode of operation of the screw pump
ensure a very low noise level and a nearly pulsation-free delivery.

Performance data
A preliminary pump selection can be effected by means of the
performance tables (pages 6 to 13). For the exact performance
data as a function of the viscosity of the fluid to be pumped and
the pump speed, please refer to the individual characteristics.

Speed of rotation
Based on the small dimensions of the rotating screw spindles
and according to pump size and design rotational speeds up to
11000 1/min are possible. With very high speeds respectively
for determining the speed limit the suction/inlet pressure conditions, the design of the shaft sealing and of the bearing as well
as the running speed of the thread flanks have to be considered.
1

ALLWEILER

Series SN... ER..


Temperature and pressure limits
admissible temperature of fluid to be pumped
with stuffing box, design U2 and KA2
with shaft sealing rings, design U3 and U4
with mechanical seal, design U....
design D....
design E....

200C
80C
150C
80C
80-150C

admissible suction lift see


NPSH values, page 5
admissible pump outlet pressure
with pump casing in c.i. (GJL-25(0)
in s.g.c.i. (GJS;-400-15)

40 bar
64 bar

admissible supply pressure


with stuffing box, design U2 and KA2
with shaft sealing rings, design U3 and U4
with unbalanced mechanical seal
design U..., D... and E...

3,0 bar
1,5 bar
5,0 ...7,0 bar

40...2200
2900...3600

no grease nipple, groove ball bearing in closed design with lifetime grease filling.

Design E:

with grease nipple. A grease volume control


(labyrinth ring) prevents overgreasing of the
bearing and thus excessive heating up to the
bearing.

Branch position/flanges
SNH, SNF, SNS: suction and delivery branch arranged symmetrically on centerline of pump and opposed in one line.
The sense of flow may be changed without
alteration of sense of rotation by turning the
pump casing by 180.
SNGH, SNGF: suction and delivery branch arranged one
after the other (U-turn) on centerline of the
pump.
SNGS:

Shaft sealing

SN...

Design D, KA:

please refer to the individual characteristiics.


For delivery pressures up to 120 bar, please refer to series SM
(pamphlet VM 618 GB/...)
depending on fluid to be pumped, viscositty, speed of rotation, pump size.
With higher supply pressures inquiry at our works necessary.

Stuffing
Shaft seal
box
rings
with ... bearing
internal external 2 pcs. 3 pcs.
U2
KA2
U3
U4

In an external, grease lubricated groove ball bearing.

with higher temperatures inquiry of our works necessary


for the attainable delivery pressure as a function of viscosity and speed,

Pump size

Bearing
In an internal groove ball bearing.
Design U...:
the groove ball bearing is lubricated by the
fluid to be pumped.

Mechanical
seal
with ... bearing
inter. external
U...
D... E...

with graphite-incorporated PTFE packing


made of NBR (buna N) resp. FPM (Viton) (Viton at surplus price)
uncooled, maintenance-free mechanical seal of the unbalanced type

suction and delivery branch arranged superimposed (U-turn) on centerline of pump.


Flanges with all designs
Suction side:
PN16 acc. to DIN EN 1092-2 (up to DN 150)
PN10 acc. to DIN EN 1092-2 (from DN 200)
Delivery side:
PN40 acc. to DIN EN 1092-2
PN64 acc. to DIN 2546
only possible with pump casing in s.g.c.i. (GJS-400-15) against surplus price

Heating
For heating of pump, for instance when pumping heavy fuel oil
or other pumping liquids which solidify when getting cool, the
following heating devices are available:

see separate technical literature

Materials...12.1 (AQ1VGG)
Rotary seal ring:
Carbon, anttimony-impregnated
Stationary seal ring: Silicon cartbide (SiC)
Auxiliary sealings:
FPM (Viton)
Spring:
CrNiMo steel
Metal parts:
CrNiMo steel
An incorporated control valve serves for a slight excess pressure within the area of the shaft sealing. As a result hereof,
during suction operation, air intalke through the shaft sealing is
avoided an dry operation of the shaft sealing prevented. The
design KA2 has no control valve and therefore should not be
used for suction operation.

Series

Heating with
steam or heat conveyor

electrical
heating
elements

heating
cover

X
X
X
X
X
X

X
X

SNH
SNF
SNS
SNGH
SNGF
SNGS

heating
cartridges

jacketed
casing

X
X
X
X
X
X

X
X
X

Pumps with jacketed casing can only be supplied in fabricated steel design

(special technical documentation).

Special mechanical seals and/or other material designs upon inquiry.

For further details of pump heating please refer to page 35.

Material
Part-No.

Denomination

Material design
W1

Pump casing

c.i. (GJL-250)

c.i. (GJL-250)

s.g.c.i. (GJS-400-15)

s.g.c.i. (GJS-400-15)

Pump casing insert with size 40 to 120


with size 210 to 3600
Pump cover, drive side
Pump cover, non-drive side
Round pump foot (only with series SNS and SNGS)
Bearing housing (only with external bearing)
Shaft sealing housing (only with internal bearing)
Pump foot
Pump casing cover
Balance bush
Seal cover
Gland (only with design U2 and KA2)
Driving spindle
Idler spindle

c.i. (GJL-200) (11)


c.i. (GJL-250) (11)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
silafont
c.i. (GJL-250)
c.i. (GJL-250)
nitride steel
nitride steel

silafont (11)
silafont (11)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
silafont
c.i. (GJL-250)
c.i. (GJL-250)
nitride steel
nitride steel

silafont (11)
silafont (11)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
silafont
c.i. (GJL-250)
c.i. (GJL-250)
nitride steel
nitride steel

c.i. (GJL-200) (11)


c.i. (GJL-250) (11)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
c.i. (GJL-250)
silafont
c.i. (GJL-250)
c.i. (GJL-250)
nitride steel
nitride steel

3
4
4
5
5
6
7
8
9
9
12
13

W2

W3

W5

When determining the material for the pump casing insert note the pressure limiting characteristics.

For pumps in fabricated steel design (because of customers' specific demands) separate technical documention is available upon request.

Series SN...ER..
Abbreviations

ALLWEILER
Pressure relief valves
All pumps can be supplied with built-on pressure relief
valve. For allocation, dimensions and connections
please refer to page 36.
Valve characteristics and sectional drawings are not
included within this pamphlet and mustt be demanded
separately.
In case pumps without built-on pressure relief valve are
re-quired, an overload protection must be provided in
the control system or as a pipeline pressure relief valve.
For allocation, dimensions and connections of pressure
relief valves for pipeline installation please refer to page
37.
Shaft coupling and protectiom against accidental
contact
Shaft coupling according to DIN 740.
A protection according to DUN 24295 against accidental
con-tact also is supplied as soon as the scope of supply
includes pump, base plate and shaft coupling or when
an intermediate bracket, respectively brackett with feet
is included in the de-livery volume.
Drive
The pumps will be coupled either directly (Series SNH,
SNGH) or by means of an intermediate bracket (Series
SNS, SNGS), respectively of a bracket with feet for floor
or wall mounting (Series SNF, SNGF) with electric
motors of the most varied kinds or with other driving
engines.
In most cases, surface cooled, three phase A.C. short
circuit motors, construction B3 or V1 are provided;
enclosure IP54 according to IEC Standard, class B
insulation, motor windings for 400 V, 50 or 60 Hz.

ALLWEILER

Series SN...ER..
Unit-assembly principle
Three-screw pumps, SN series.
Same delivery elements with different types of casing construction.

For series SNC, SNG, SNT and SNTG pump dimensions and sectional

drawings are available upon request


For series SNHBA and SNFBA see pamphlet VM 639 GB/...

Pump casing insert + Screw spindle set

For submersible pumps designed to customers' specification dimensions

drawings will be prepared per order

Performance survey
For nominal pump outputs not covered by the type SN further pump series of single entry three-screw pumps are available according to the following survey (stated performances refer to 50 Hz speeds).

ALLWEILER

Series SN...ER..
NPSH req. (m)

The values as indicated apply to airless fluids to be pumped (a safety allowances of 0.5 m is already included). In case of fluids
to be pumped with air pockets (unsolved air), either the pump must be adapted or allowances on the stated NPSH values are
necessary. For these purposes, by all means inquire at our works.
For exact NPSH values in dependence of the viscosity (also for other viscosities than those mentioned below) and of the pump
rotational speed (also for other speeds of rotation than those mentioned below), please refer to the individual NPSH graphs.

Kinematic viscosity v

Pump
size

SN...

6 mm /s

40 mm2/s

380 mm2/s

Speed n [1/min]

Speed n [1/min]

Speed n [1/min]

1450 m

1750 m

2900 m

3500 m

1450 m

1750 m

2900 m

3500 m

1450 m

40-38
40-46
40-54

3,0
3,0
4,9

3,0
3,0
5,0

3,0
3,0
5,4

3,0
3,0
5,7

3,0
3,0
5,4

3,0
3,0
5,5

3,0
3,0
5,9

3,0
3,0
6,4

3,0
3,0
6,9

80-36
80-42
80-46
80-54

3,0
3,0
3,0
5,0

3,0
3,0
3,0
5,1

3,0
3,0
3,0
5,7

3,0
3,0
3,3
6,4

3,0
3,0
3,0
5,5

3,0
3,0
3,0
5,6

3,0
3,0
3,0
6,5

3,0
3,1
3,8
7,2

120-42
120-46
120-54

3,0
3,0
5,0

3,0
3,0
5,2

3,0
3,0
6,1

3,0
3,8
6,4

3,0
3,0
5,5

3,0
3,0
5,7

3,0
3,4
6,9

210-40
210-46
210-54

3,0
3,0
5,2

3,0
3,0
5,4

3,0
3,8
7,1

3,6
5,0
-

3,0
3,0
5,7

3,0
3,0
6,0

280-43
280-46
280-54

3,0
3,0
5,3

3,0
3,0
5,5

3,7
4,5
8,0

4,8
6,1
-

3,0
3,0
5,8

440-40
440-46
440-52
440-54

3,0
3,0
4,5
5,4

3,0
3,0
4,9
5,9

3,8
5,7

5,2
8,1
-

660-40
660-44
660-46
660-51
660-54

3,0
3,0
3,0
5,5
5,8

3,0
3,0
3,4
6,0
6,5

5,1
6,4
7,5
-

940-42
940-46
940-50
940-54

3,0
3,0
5,6
6,1

3,1
3,4
6,3
7,1

2900 m

3500 m

3,0
3,0
7,0

3,0
3,5
8,0

3,3
4,5
8,8

3,0
3,0
3,0
7,2

3,0
3,0
3,0
7,3

3,1
3,8
4,6

3,7
4,8
6,3

3,6
4,5
8,2

3,0
3,0
7,2

3,0
3,0
7,5

4,4
5,4

5,8
7,6

3,2
4,5
8,1

4,2
6,0
-

3,0
3,0
7,5

3,0
3,5
8,0

5,2
7,5

7,0

3,0
3,0
6,2

4,3
5,3
-

5,8
7,5
-

3,0
3,3
7,8

3,6
4,1
8,4

7,3

3,0
3,0
5,9
6,1

3,0
3,2
6,4
6,6

4,6
6,9

6,4

3,1
3,8
7,9
8,2

3,8
5,0
8,7

7,8

7,2
8,9
-

3,0
3,0
3,1
6,2
6,5

3,0
3,6
3,9
6,8
7,3

6,1
7,7

8,7

3,6
4,3
4,6
8,4
8,9

4,7
5,6
6,5

6,8

3,0
3,5
6,4
6,9

3,6
4,6
7,2
8,1

8,0

4,4
5,6
8,8

5,8
7,9

1300-38
1300-42
1300-44
1300-46
1300-54

3,0
3,0
3,0
3,4
6,6

3,0
3,6
4,0
4,6
8,0

6,0
8,3
-

3,0
3,3
3,6
4,0
7,5

3,4
4,2
4,8
5,4

7,4

4,1
5,2
5,8
7,6

5,4
7,2
8,2

1700-42
1700-46

3,2

4,3

3,8

5,0

6,1

8,5

3,4

5,4

4,6

6,6

7,9

2200-42

3,7

4,9

4,4

6,0

7,3

2200-46

4,2

6,3

5,3

7,6

2900-40

4,0

5,5

4,8

6,7

7,9

3600-46

5,7

8,1

6,9

1750 m

Inlet pressure necessary

ALLWEILER

Series SN...ER..
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
n = 1450 1/min

Pump
size

Delivery
pressure

SN...

p bar

Q
l/min

5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64

29,20
26,90
22,90
19,20
15,70
38,70
35,70
30,10
25,00
51,10
46,20
37,40
53,70
50,00
43,40
37,30
31,60
26,00
64,50
59,50
50,50
42,20
34,30
76,90
72,00
63,00
54,70
100,00
92,30
77,90
91,90
85,50
73,80
63,10
52,90
110,00
104,00
92,30
81,50
145,00
135,00
116,00
-

40-38

40-46

40-54

80-36

80-42

80-46

80-54

120-42

120-46

120-54

v = 6 mm 2 /s
P
kW
0,42
0,168
1,21
1,75
2,28
0,50
0,86
1,57
2,28
0,63
1,10
2,06
0,70
1,18
2,15
3,12
4,09
5,06
0,80
1,39
2,57
3,74
4,92
0,90
1,60
2,98
4,37
1,13
2,05
3,88
1,19
2,03
3,69
5,36
7,02
1,35
2,33
4,31
6,28
1,68
2,99
5,62
-

v = 40 mm2/s

n = 2900 1/min
v = 380 mm2/s

v = 6 mm2/s

v = 40 mm2/s

v = 380 mm2/s

Q
l/min

P
kW

Q
l/min

P
kW

Q
l/min

P
kW

Q
l/min

P
kW

Q
l/min

P
kW

30,70
29,70
28,00
26,30
24,80
23,30
21,30
40,90
39,60
37,20
34,90
32,80
30,80
28,00
54,50
52,40
48,60
45,00
41,60
56,20
54,60
51,70
49,00
46,50
44,10
40,80
68,00
65,80
61,80
58,20
54,80
51,40
46,90
80,40
78,30
74,30
70,70
67,20
63,90
59,40
106,00
102,00
96,10
90,30
84,80
96,50
93,70
88,60
83,90
79,50
75,20
69,40
115,00
112,00
107,00
102,00
97,90
93,60
87,90
152,00
148,00
140,00
132,00
125,00
-

0,42
0,68
1,21
1,75
2,28
2,81
3,56
0,50
0,86
1,57
2,28
2,99
3,70
4,69
0,63
1,10
2,06
3,01
3,96
0,70
1,18
2,15
3,12
4,09
5,06
6,42
0,80
1,39
2,57
3,74
4,92
6,10
7,75
0,90
1,60
2,98
4,37
5,75
7,14
9,08
1,13
2,05
3,88
5,72
7,55
1,19
2,03
3,69
5,36
7,02
8,69
11,00
1,35
2,33
4,31
6,28
8,25
10,20
13,00
1,68
2,99
5,62
8,25
10,90
-

31,50
31,10
30,50
29,90
29,30
28,80
28,10
42,00
41,50
40,60
39,80
39,00
38,20
37,20
56,20
55,40
54,00
52,60
51,40
50,10
48,50
57,50
56,90
55,90
54,90
54,00
53,10
51,90
69,70
68,90
67,40
66,10
64,80
63,60
62,00
82,20
81,40
79,90
78,60
77,30
76,10
74,40
109,00
107,00
105,00
103,00
101,00
98,80
96,10
98,70
97,70
95,80
94,10
92,50
90,90
88,80
117,00
116,00
114,00
113,00
111,00
109,00
107,00
156,00
154,00
151,00
148,00
146,00
143,00
140,00

0,42
0,68
1,21
1,75
2,28
2,81
3,56
0,50
0,86
1,57
2,28
2,99
3,70
4,69
0,63
1,10
2,06
3,01
3,96
4,92
6,25
0,70
1,18
2,15
3,12
4,09
5,06
6,42
0,80
1,39
2,57
3,74
4,92
6,10
7,75
0,90
1,60
2,98
4,37
5,75
7,14
9,08
1,13
2,05
3,88
5,72
7,55
9,39
12,00
1,19
2,03
3,69
5,36
7,02
8,69
11,00
1,35
2,33
4,31
6,28
8,25
10,20
13,00
1,68
2,99
5,62
8,25
10,90
13,50
17,20

61,10
58,90
54,80
51,10
47,60
44,20
39,60
81,30
78,20
72,70
67,60
62,70
58,00
108,00
103,00
94,60
86,40
112,00
108,00
102,00
95,50
89,80
84,20
76,70
135,00
130,00
121,00
113,00
105,00
97,40
160,00
155,00
146,00
138,00
130,00
122,00
210,00
202,00
188,00
175,00
192,00
185,00
174,00
163,00
153,00
143,00
229,00
222,00
211,00
200,00
190,00
180,00
303,00
293,00
274,00
257,00
-

1,13
1,66
2,73
3,79
4,86
5,92
7,41
1,31
2,02
3,44
4,86
6,28
7,70
1,55
2,51
4,41
6,32
1,81
2,78
4,72
6,66
8,60
10,50
13,30
2,02
3,20
5,55
7,91
10,30
12,60
2,23
3,61
6,38
9,16
11,90
14,70
2,68
4,51
8,18
11,90
3,11
4,77
8,10
11,40
14,80
18,10
3,41
5,39
9,33
13,30
17,20
21,20
4,07
6,70
12,00
17,20
-

62,60
61,70
59,90
58,30
56,70
55,20
53,20
83,50
82,10
79,70
77,50
75,40
73,40
70,60
112,00
110,00
106,00
102,00
98,80
95,60
91,20
114,00
113,00
110,00
107,00
105,00
102,00
99,00
139,00
136,00
133,00
129,00
125,00
122,00
118,00
164,00
161,00
157,00
154,00
150,00
147,00
143,00
216,00
213,00
206,00
200,00
195,00
190,00
183,00
196,00
194,00
189,00
184,00
179,00
175,00
169,00
233,00
230,00
225,00
221,00
216,00
212,00
206,00
310,00
306,00
297,00
290,00
283,00
276,00
267,00

1,13
1,66
2,73
3,79
4,86
5,92
7,41
1,31
2,02
3,44
4,86
6,28
7,70
9,68
1,55
2,51
4,41
6,32
8,23
10,10
12,80
1,81
2,78
4,72
6,66
8,60
10,50
13,30
2,02
3,20
5,55
7,91
10,30
12,60
15,90
2,23
3,61
6,38
9,16
11,90
14,70
18,60
2,68
4,51
8,18
11,90
15,50
19,20
24,30
3,11
4,77
8,10
11,40
14,80
18,10
22,80
3,41
5,39
9,33
13,30
17,20
21,20
26,70
4,07
6,70
12,00
17,20
22,50
27,70
35,10

63,40
63,10
62,40
61,80
61,30
60,70
60,00
84,50
84,00
83,20
82,30
81,60
80,80
79,80
113,00
113,00
111,00
110,00
109,00
107,00
106,00
116,00
115,00
114,00
113,00
112,00
111,00
110,00
140,00
140,00
138,00
137,00
136,00
134,00
133,00
165,00
165,00
163,00
162,00
160,00
159,00
158,00
219,00
217,00
215,00
213,00
211,00
209,00
206,00
199,00
198,00
196,00
194,00
192,00
191,00
189,00
236,00
234,00
233,00
231,00
229,00
228,00
226,00
314,00
312,00
309,00
306,00
304,00
301,00
298,00

1,13
1,66
2,73
3,79
4,86
5,92
7,41
1,31
2,02
3,44
4,86
6,28
7,70
9,68
1,55
2,51
4,41
6,32
8,23
10,10
12,80
1,81
2,78
4,72
6,66
8,60
10,50
13,30
2,02
3,20
5,55
7,91
10,30
12,60
15,90
2,23
3,61
6,38
9,16
11,90
14,70
18,60
2,68
4,51
8,18
11,90
15,50
19,20
24,30
3,11
4,77
8,10
11,40
14,80
18,10
22,80
3,41
5,39
9,33
13,30
17,20
21,20
26,70
4,07
6,70
12,00
17,20
22,50
27,70
35,10

The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other viscosities
than those mentioned above) and the pump speed, please refer to the individual characteristics.
6

VM 617 GB / 11.98

4000

ALLWEILER

Series SN...ER..

Performance table Delivery flow Q [1/min] and power absorbed P [kW]


n = 1450 1/min

Pump
size

Delivery
pressure

SN...

p bar

Q
l/min

5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64

160,00
153,00
139,00
127,00
116,00
200,00
190,00
172,00
155,00
263,00
247,00
218,00
233,00
221,00
199,00
179,00
266,00
254,00
232,00
212,00
350,00
331,00
296,00
335,00
322,00
300,00
280,00
260,00
425,00
408,00
377,00
349,00
492,00
465,00
416,00
552,00
525,00
476,00
-

210-40

210-46

210-54

280-43

280-46

280-54

440-40

440-46

440-52

440-54

v = 6 mm 2 /s
P
kW
1,97
3,38
6,19
9,01
11,80
2,33
4,10
7,63
11,20
2,92
5,28
9,99
2,92
4,98
9,11
13,20
3,19
5,53
10,20
14,90
3,97
7,09
13,30
4,17
7,09
12,90
18,80
24,60
4,96
8,68
16,10
23,50
5,63
10,00
18,80
6,13
11,00
20,80
-

v = 40 mm2/s
Q
l/min
165,00
162,00
156,00
151,00
146,00
141,00
134,00
207,00
202,00
195,00
187,00
180,00
174,00
165,00
274,00
267,00
255,00
243,00
232,00
241,00
236,00
227,00
218,00
210,00
202,00
191,00
274,00
269,00
259,00
251,00
242,00
234,00
223,00
364,00
355,00
340,00
326,00
313,00
343,00
338,00
328,00
319,00
311,00
303,00
292,00
436,00
429,00
416,00
403,00
392,00
380,00
365,00
510,00
499,00
477,00
458,00
439,00
421,00
571,00
559,00
538,00
518,00
500,00
-

n =2900 1/min
v = 380 mm2/s

P
kW

Q
l/min

P
kW

1,97
3,38
6,19
9,01
11,80
14,60
18,60
2,33
4,10
7,63
11,20
14,70
18,20
23,20
2,92
5,28
9,99
14,70
19,40
2,92
4,98
9,11
13,20
17,40
21,50
27,30
3,19
5,53
10,20
14,90
19,60
24,20
30,80
3,97
7,09
13,30
19,60
25,80
4,17
7,09
12,90
18,80
24,60
30,40
38,60
4,96
8,68
16,10
23,50
31,00
38,40
48,80
5,63
10,00
18,80
27,50
36,30
45,00
6,13
11,00
20,80
30,50
40,30
-

168,00
166,00
164,00
162,00
161,00
159,00
156,00
210,00
209,00
206,00
203,00
201,00
198,00
195,00
280,00
277,00
273,00
268,00
264,00
260,00
255,00
245,00
243,00
240,00
237,00
234,00
231,00
227,00
278,00
276,00
273,00
269,00
266,00
263,00
259,00
370,00
367,00
362,00
356,00
351,00
347,00
340,00
348,00
346,00
342,00
339,00
336,00
332,00
328,00
442,00
440,00
435,00
430,00
426,00
422,00
416,00
520,00
515,00
508,00
500,00
493,00
487,00
478,00
580,00
576,00
568,00
561,00
554,00
547,00
538,00

1,97
3,38
6,19
9,01
11,80
14,60
18,60
2,33
4,10
7,63
11,20
14,70
18,20
23,20
2,92
5,28
9,99
14,70
19,40
24,10
30,70
2,92
4,98
9,11
13,20
17,40
21,50
27,30
3,19
5,53
10,20
14,90
19,60
24,20
30,80
3,97
7,09
13,30
19,60
25,80
32,00
40,80
4,17
7,09
12,90
18,80
24,60
30,40
38,60
4,96
8,68
16,10
23,50
31,00
38,40
48,80
5,63
10,00
18,80
27,50
36,30
45,00
57,30
6,13
11,00
20,80
30,50
40,30
50,10
63,70

v = 6 mm2/s
Q
l/min
329,00
322,00
308,00
296,00
285,00
274,00
412,00
402,00
384,00
367,00
352,00
336,00
546,00
530,00
501,00
475,00
481,00
469,00
447,00
427,00
408,00
389,00
546,00
534,00
512,00
492,00
473,00
455,00
724,00
705,00
670,00
638,00
685,00
673,00
650,00
630,00
610,00
591,00
870,00
853,00
823,00
795,00
768,00
742,00
1017,00
990,00
941,00
896,00
853,00
1138,00
1111,00
1062,00
1017,00
-

P
kW
5,06
7,87
13,50
19,10
24,80
30,40
5,78
9,31
16,40
23,50
30,50
37,60
6,96
11,70
21,10
30,50
7,53
11,70
19,90
28,20
36,50
44,70
8,08
12,80
22,10
31,50
40,80
50,20
9,64
15,90
28,30
40,80
10,80
16,70
28,30
40,00
51,70
63,40
12,40
19,90
34,70
49,60
64,40
79,30
13,80
22,50
40,00
57,50
75,00
14,80
24,50
44,00
63,60
-

v = 40 mm2/s
Q
l/min
334,00
331,00
325,00
320,00
315,00
310,00
303,00
419,00
415,00
407,00
400,00
393,00
386,00
377,00
557,00
550,00
538,00
526,00
515,00
504,00
490,00
489,00
484,00
475,00
466,00
457,00
449,00
439,00
555,00
549,00
540,00
531,00
523,00
515,00
504,00
738,00
729,00
714,00
700,00
687,00
674,00
657,00
694,00
688,00
678.00
669.00
661,00
653,00
642,00
882,00
875,00
861,00
849,00
837,00
826,00
811,00
1036,00
1024,00
1003,00
983,00
964,00
946,00
922,00

P
kW
5,06
7,87
13,50
19,10
24,80
30,40
38,30
5,78
9,31
16,40
23,50
30,50
37,60
47,50
6,96
11,70
21,10
30,50
40,00
49,40
62,60
7,53
11,70
19,90
28,20
36,50
44,70
56,30
8,08
12,80
22,10
31,50
40,80
50,20
63,30
9,64
15,90
28,30
40,80
53,30
65,80
83,20
10,80
16,70
28,30
40,00
51,70
63,40
79,70
12,40
19,90
34,70
49,60
64,40
79,30
100,00
13,80
22,50
40,00
57,50
75,00
92,50
117,00

v = 380 mm2/s
Q
l/min
337,00
335,00
333,00
331,00
330,00
328,00
325,00
422,00
421,00
418,00
415,00
413,00
410,00
407,00
563,00
560,00
555,00
551,00
547,00
543,00
538,00
493,00
491,00
488,00
485,00
481,00
478,00
474,00
559,00
557,00
553,00
550,00
547,00
544,00
540,00
744,00
741,00
736,00
731,00
726,00
721,00
714,00
698,00
696,00
692,00
689,00
686,00
683,00
678,00
888,00
885,00
880,00
876,00
871,00
867,00
862,00
1045,00
1041,00
1033,00
1025,00
1019,00
1012,00
1003,00

P
kW
5,06
7,87
13,50
19,10
24,80
30,40
38,30
5,78
9,31
16,40
23,50
30,50
37,60
47,50
6,96
11,70
21,10
30,50
40,00
49,40
62,60
7,53
11,70
19,90
28,20
36,50
44,70
56,30
8,08
12,80
22,10
31,50
40,80
50,20
63,30
9,64
15,90
28,30
40,80
53,30
65,80
83,20
10,80
16,70
28,30
40,00
51,70
63,40
79,70
12,40
19,90
34,70
49,60
64,40
79,30
100,00
13,80
22,50
40,00
57,50
75,00
92,50
117,00

The performance datas are valid for all designs. For exact deliveries as a f unction of the viscosity of the fluid to be pumped (also for other viscosities than
those mentioned above) and the pump speed, please refer to the individual characteristics.
VM 617 GB / 11.98

4001

ALLWEILER

Series SN...ER..

Performance table Delivery flow Q [1/min] and power absorbed P [kW]


Pump
size

Delivery
pressure

SN...

p bar

n = 1450 1/min
2

v = 6 mm /s
Q
l/min

v = 40 mm /s
Q
l/min
531,00
524,00
511,00
499,00
488,00
477,00
462,00

P
kW
6,30
10,80
19,80
28,80
37,80
46,80
59,50

n =2900 1/min
2

v = 380 mm /s
Q
l/min
537,00
534,00
530,00
525,00
521,00
517,00
511,00

P
kW
6,30
10,80
19,80
28,80
37,80
46,80
59,50

v = 6 mm /s
Q
l/min
1060,00
1044,00
1014,00
987,00
960,00
935,00
-

P
kW
16,20
25,20
43,20
61,20
79,30
97,30
-

v = 40 mm2/s
Q
l/min

v = 380 mm2/s
Q
l/min

660-40

5
10
20
30
40
50
64

520,00
503,00
474,00
446,00
-

P
kW
6,30
10,30
19,80
28,80
-

1072,00
1065,00
1052,00
1040,00
1028,00
1017,00
1002,00

P
kW
16,20
25,20
43,20
61,20
79,30
97,30
123,00

1078,00
1075,00
1070,00
1066,00
1061,00
1057,00
1052,00

P
kW
16,20
25,20
43,20
61,20
79,30
97,30
123,00

660-44

5
10
20
30
40
50
64

587,00
565,00
524,00
486,00
-

6,93
12,10
22,30
32,60
-

603,00
593,00
575,00
559,00
543,00
529,00
-

6,93
12,10
22,30
32,60
42,80
53,10
-

611,00
607,00
601,00
594,00
589,00
583,00
576,00

6,93
12,10
22,30
32,60
42,80
53,10
67,40

1202,00
1180,00
1139,00
1102,00
1066,00
-

17,50
27,70
48,20
68,70
89,20
-

1218,00
1209,00
1191,00
1174,00
1159,00
1144,00
1124,00

17,50
27,70
48,20
68,70
89,20
110,00
138,00

1226,00
1222,00
1316,00
1210,00
1204,00
1198,00
1191,00

17,50
27,70
48,20
68,70
89,20
110,00
138,00

660-46

5
10
20
30
40
50
64

637,00
614,00
574,00
-

7,34
12,90
24,00
-

653,00
643,00
625,00
609,00
593,00
578,00
-

7,34
12,90
24,00
35,10
46,10
57,20
-

661,00
657,00
650,00
644,00
639,00
633,00
625,00

7,34
12,90
24,00
35,10
46,10
57,20
72,80

1302,00
1280,00
1239,00
1201,00
1166,00
-

18,30
29,40
51,50
73,70
95,90
-

1318,00
1308,00
1291,00
1274,00
1259,00
1244,00
1223,00

18,30
29,40
51,50
73,70
95,90
118,00
149,00

1326,00
1322,00
1316,00
1310,00
1304,00
1298,00
1291,00

18,30
29,40
51,50
73,70
95,90
118,00
149,00

660-51

5
10
20
30
40
50
64

745,00
709,00
644,00
-

8,38
15,00
28,10
-

770,00
755,00
726,00
700,00
675,00
-

8,38
15,00
28,10
41,30
54,50
-

783,00
777,00
766,00
757,00
747,00
738,00
726,00

8,38
15,00
28,10
41,30
54,50
67,60
86,10

1535,00
1499,00
1433,00
1373,00
-

20,40
33,50
59,90
86,20
-

1560,00
1544,00
1516,00
1490,00
1465,00
1441,00
-

20,40
33,50
59,90
86,20
113,00
139,00
-

1573,00
1567,00
1556,00
1546,00
1537,00
1528,00
1516,00

20,40
33,50
59,90
86,20
113,00
139,00
176,00

660-54

5
10
20
30
40
50
64

853,00
817,00
752,00
-

9,28
16,80
31,70
-

878,00
863,00
834,00
808,00
-

9,28
16,80
31,70
46,70
-

891,00
885,00
874,00
865,00
855,00
847,00
835,00

9,28
16,80
31,70
46,70
61,70
76,60
97,60

1751,00
1715,00
1650,00
1589,00
-

22,20
37,10
67,10
97,00
-

1776,00
1761,00
1732,00
1706,00
1681,00
1657,00
-

22,20
37,10
67,10
97,00
127,00
157,00
-

1789,00
1783,00
1772,00
1763,00
1753,00
1745,00
1733,00

22,20
37,10
67,10
97,00
127,00
157,00
199,00

940-42

5
10
20
30
40
50
64

753,00
724,00
671,00
622,00
-

9,16
15,70
28,90
42,00
-

773,00
761,00
738,00
716,00
696,00
677,00
-

9,16
15,70
28,90
42,00
55,20
68,40
-

783,00
779,00
770,00
762,00
755,00
748,00
738,00

9,16
15,70
28,90
42,00
55,20
68,40
86,80

1542,00
1513,00
1460,00
1412,00
1365,00
-

23,50
36,60
62,90
89,20
116,00
-

1563,00
1550,00
1527,00
1506,00
1486,00
1466,00
1440,00

23,50
36,60
62,90
89,20
116,00
142,00
179,00

1573,00
1568,00
1559,00
1552,00
1544,00
1537,00
1527,00

23,50
36,60
62,90
89,20
116,00
142,00
179,00

940-46

5
10
20
30
40
50
64

911,00
882,00
829,00
-

10,50
18,40
34,20
-

931,00
919,00
896,00
874,00
854,00
835,00
-

10,50
18,40
34,20
49,90
65,70
81,50
-

941,00
937,00
928,00
920,00
913,00
905,00
896,00

10,50
18,40
34,20
49,90
65,70
81,50
104,00

1858,00
1829,00
1776,00
1727,00
1681,00
-

26,10
41,90
73,50
105,00
137,00
-

1878,00
1866,00
1843,00
1821,00
1801,00
1782,00
1756,00

26,10
41,90
73,50
105,00
137,00
168,00
212,00

1888,00
1884,00
1875,00
1867,00
1860,00
1853,00
1843,00

26,10
41,90
73,50
105,00
137,00
168,00
212,00

940-50

5
10
20
30
40
50
64

1020,00
974,00
889,00
-

11,60
20,60
38,50
-

1053,00
1033,00
996,00
962,00
930,00
-

11,60
20,60
38,50
56,50
74,50
-

1069,00
1062,00
1048,00
1036,00
1024,00
1012,00
997,00

11,60
20,60
38,50
56,50
74,50
92,50
118,00

2099,00
2052,00
1968,00
1890,00
-

28,30
46,30
86,20
118,00
-

2132,00
2112,00
2075,00
2041,00
2009,00
1977,00
1935,00

28,30
46,30
82,20
118,00
154,00
190,00
240,00

2148,00
2140,00
2127,00
2114,00
2102,00
2091,00
2075,00

28,30
46,30
82,20
118,00
154,00
190,00
240,00

940-54

5
10
20
30
40
50
64

1205,00
1158,00
1074,00
-

13,10
23,60
44,70
-

1237,00
1217,00
1180,00
1146,00
-

13,10
23,60
44,70
65,70
-

1253,00
1246,00
1232,00
1220,00
1208,00
1196,00
1181,00

13,10
23,60
44,70
65,70
86,80
108,00
137,00

2467,00
2421,00
2336,00
2258,00
-

31,40
52,40
94,50
137,00
-

2500,00
2480,00
2443,00
2409,00
2377,00
2346,00
-

31,40
52,40
94,50
137,00
179,00
221,00
-

2516,00
2509,00
2495,00
2483,00
2471,00
2459,00
2444,00

31,40
52,40
94,50
137,00
179,00
221,00
280,00

The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other viscosities
than those mentioned above) and the pump speed, please refer to the individual characteristics
VM 617 GB/11.98

4002

ALLWEILER

Series SN...ER..
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size

Delivery
pressure

SN...

p bar

n = 1450 1/min
2

v = 6 mm /s

v = 40 mm /s

n =2900 1/min
2

v = 380 mm /s

v = 6 mm /s

v = 40 mm2/s

v = 380 mm2/s

1300-38

5
10
20
30
40
50
64

Q
l/min
902,00
875,00
827,00
782,00
-

P
kW
11,30
19,10
34,70
50,30
-

Q
l/min
921,00
909,00
888,00
869,00
850,00
832,00
808,00

P
kW
11,30
19,10
34,70
50,30
65,90
81,50
103,00

Q
l/min
930,00
926,00
918,00
911,00
904,00
897,00
888,00

P
kW
11,30
19,10
34,70
50,30
65,90
81,50
103,00

Q
l/min
1837,00
1811,00
1762,00
1717,00
1675,00
1634,00
-

P
kW
29,70
45,30
76,50
108,00
139,00
170,00
-

Q
l/min
1856,00
1845,00
1823,00
1804,00
1785,00
1768,00
1 743,00

P
kW
29,70
45,30
76,50
108,00
139,00
170,00
214,00

Q
l/min
1865,00
1861,00
1853,00
1846,00
1839,00
1833,00
1824,00

P
kW
29,70
45,30
76,50
108,00
139,00
170,00
214,00

1300-42

5
10
20
30
40
50
64

1072,00
1035,00
969,00
907,00
-

12,80
22,20
40,80
59,40
-

1097,00
1081,00
1052,00
1026,00
1000,00
976,00
-

12,80
22,20
40,80
59,40
78,00
96,60
-

1110,00
1104,00
1093,00
1083,00
1074,00
1065,00
1053,00

12,80
22,20
40,80
59,40
78,00
96,60
123,00

2189,00
2152,00
2086,00
2025,00
1967,00
-

32,70
51,40
88,60
126,00
163,00
-

2215,00
2199,00
2170,00
2143,00
2118,00
2093,00
2060,00

32,70
51,40
88,60
126,00
1 63,00
200,00
252,00

2227,00
2221,00
2211,00
2201,00
2191,00
2182,00
2170,00

32,70
51,40
88,60
126,00
163,00
200,00
252,00

1300-44

5
10
20
30
40
50
64

1149,00
1113,00
1047,00
985,00
-

13,50
23,50
43,40
63,30
-

1175,00
1159,00
1130,00
1104,00
1078,00
1054,00
-

13,50
23,50
43,40
63,30
83,20
103,00
-

1188,00
1182,00
1171,00
1161,00
1152,00
1143,00
1131,00

13,50
23,50
43,40
63,30
83,20
103,00
131,00

1300-46

5
10
20
30
40
50
64

1253,00
1217,00
1150,00
-

14,40
25,20
46,80
-

1279,00
1263,00
1234,00
1208,00
1182,00
1158,00
-

14,40
25,20
46,80
68,50
90,10
112,00
-

1292,00
1286,00
1275,00
1265,00
1256,00
1247,00
1235,00

14,40
25,20
46,80
68,50
90,10
112,00
142,00

1300-54

5
10
20
30
40
50
64

1655,00
1596,00
1490,00
-

17,90
32,30
61,10
-

1696,00
1670,00
1624,00
1581,00
-

17,90
32,30
61,10
89,90
-

1716,00
1707,00
1690,00
1674,00
1659,00
1644,00
1625,00

17,90
32,30
61,10
89,90
119,00
148,00
188,00

5
10
20
30
40
50
64
5
10
20
30
40
50
64

1437,00
1391,00
1310,00
1234,00
1673,00
1627,00
1545,00
-

17,20
29,70
54,60
79,50
19,20
33,60
62,40
-

1469,00
1449,00
1414,00
1381,00
1349,00
1319,00
1705,00
1685,00
1649,00
1617,00
1585,00
1555,00
-

17,20
29,70
54,60
79,50
104,00
129,00
19,20
33,60
62,40
91,20
120,00
149,00
-

1484,00
1477,00
1464,00
1452,00
1440,00
1429,00
1414,00
1720,00
1713,00
1700,00
1688,00
1676,00
1665,00
1650,00

17,20
29,70
54,60
79,50
104,00
129,00
164,00
19,20
33,60
62,40
91,20
120,00
149,00
189,00

2200-42

5
10
20
30
40
50
64

1877,00
1823,00
1724,00
1633,00
-

22,50
38,80
71,20
104,00
-

1916,00
1892,00
1849,00
1809,00
1772,00
1735,00
-

22,50
38,80
71,20
104,00
136,00
168,00
-

1935,00
1926,00
1910,00
1895,00
1881,00
1868,00
1850,00

22,50
38,80
71,20
104,00
136,00
1 68,00
214,00

2200-46

5
10
20
30
40
50
64

2177,00
2122,00
2023,00
-

25,00
43,70
81,20
-

2215,00
2191,00
2148,00
2109,00
2071,00
2035,00
-

25,00
43,70
81,20
119,00
156,00
193,00
-

2234,00
2225,00
2209,00
2195,00
2181,00
2167,00
2149,00

25,00
43,70
81,20
119,00
156,00
193,00
246,00

2900-40

5
10
20
30
40
50
64

2769,00
2693,00
2555,00
-

33,40
57,30
105,00
-

2823,00
2790,00
2730,00
2674,00
2621,00
2570,00
-

33,40
57,30
105,00
153,00
201,00
248,00
-

2849,00
2837,00
2815,00
2794,00
2775,00
2756,00
2731,00

33,40
57,30
105,00
153,00
201,00
248,00
315,00

3600-46

5
10
20
30
40
50
64

3470,00
3393,00
3255,00
-

39,30
69,00
128,00
-

3523,00
3490,00
3430,00
3374,00
3321,00
-

39,30
69,00
128,00
188,00
247,00
-

3550,00
3537,00
3515,00
3495,00
3475,00
3456,00
3431,00

39,30
69,00
128,00
188,00
247,00
307,00
390,00

1700-42

1700-46

The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other viscosities
than those mentioned above) and the pump speed, please refer to the individual characteristics.
VM 617 GB / 11.98

4003

ALLWEILER

Series SN...ER.
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size

Delivery
pressure

SN...

p bar

40-38

40-46

40-54

80-36

80-42

80-46

80-54

120-42

120-46

120-54

5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64

n = 1450 1/min
v = 6 mm 2 /s
Q
l/min
35,80
33,50
29,50
25,80
22,30
18,90
47,50
44,50
38,90
33,80
62,90
58,00
49,20
65,70
62,00
55,50
49,40
43,60
38,00
79,10
74,10
65,10
56,80
48,90
94,10
89,20
80,20
71,90
123,00
115,00
101,00
113,00
106,00
94,50
83,80
73,50
135,00
128,00
117,00
106,00
178,00
167,00
149,00
-

P
kW
0,54
0,86
1,50
2,15
2,79
3,43
0,65
1,07
1,93
2,79
0,79
1,37
2,52
0,89
1,48
2,65
3,82
4,99
6,16
1,02
1,73
3,15
4,57
5,99
1,14
1,98
3,65
5,32
1,41
2,52
4,74
1,53
2,54
4,55
6,56
8,57
1,72
2,91
5,29
7,67
2,11
3,70
6,87
-

v = 40 mm2/s

n =2900 1/min
v = 380 mm2/s

v = 6 mm2/s

v = 40 mm2/s

v = 380 mm2/s

Q
l/min

P
kW

Q
l/min

P
kW

Q
l/min

P
kW

Q
l/min

P
kW

Q
l/min

P
kW

37,30
36,30
34,60
32,90
31,40
29,90
27,90
49,70
48,40
46,00
43,70
41,60
39,60
36,80
66,40
64,20
60,40
56,80
53,50
50,20
68,20
66,60
63,80
61,10
58,50
56,10
52,80
82,60
80,40
76,50
72,80
69,40
66,10
61,60
97,60
95,50
91,50
87,90
84,40
81,10
76,60
129,00
125,00
119,00
113,00
108,00
102,00
117,00
114,00
109,00
105,00
100,00
95,90
90,10
139,00
137,00
132,00
127,00
122,00
118,00
112,00
185,00
180,00
172,00
165,00
158,00
151,00
-

0,54
0,86
1,50
2,15
2,79
3,43
4,33
0,65
1,07
1,93
2,79
3,64
4,50
5,70
0,79
1,37
2,52
3,67
4,82
5,97
0,89
1,48
2,65
3,82
4,99
6,16
7,80
1,02
1,73
3,15
4,57
5,99
7,41
9,40
1,14
1,98
3,65
5,32
7,00
8,67
11,00
1,41
2,52
4,74
6,95
9,17
11,40
1,53
2,54
4,55
6,56
8,57
10,60
13,40
1,72
2,91
5,29
7,67
10,10
12,40
15,80
2,11
3,70
6,87
10,00
13,20
16,40
-

38,10
37,70
37,10
36,50
35,90
35,40
34,70
50,80
50,30
49,40
48,60
47,80
47,10
46,00
68,00
67,20
65,80
64,50
63,20
62,00
60,30
69,50
68,90
67,90
66,90
66,00
65,10
63,90
84,30
83,50
82,10
80,70
79,50
78,20
76,60
99,40
98,60
97,10
95,80
94,50
93,30
91,60
131,00
130,00
128,00
126,00
124,00
122,00
119,00
119,00
118,00
117,00
115,00
113,00
112,00
110,00
142,00
141,00
139,00
137,00
135,00
134,00
132,00
188,00
187,00
184,00
181,00
178,00
176,00
173,00

0,54
0,86
1,50
2,15
2,79
3,43
4,33
0,65
1,07
1,93
2,79
3,64
4,50
5,70
0,79
1,37
2,52
3,67
4,82
5,97
7,58
0,89
1,48
2,65
3,82
4,99
6,16
7,80
1,02
1,73
3,15
4,57
5,99
7,41
9,40
1,14
1,98
3,65
5,32
7,00
8,67
11,00
1,41
2,52
4,74
6,95
9,17
11,40
14,50
1,53
2,54
4,55
6,56
8,57
10,60
13,40
1,72
2,91
5,29
7,67
10,10
12,40
15,80
2,11
3,70
6,87
10,00
13,20
16,40
20,80

74,30
72,10
68,10
64,40
60,80
57,40
52,80
98,90
95,90
90,30
85,20
80,30
75,70
132,00
127,00
118,00
110,00
102,00
136,00
132,00
126,00
120,00
114,00
108,00
101,00
164,00
159,00
150,00
142,00
134,00
127,00
116,00
194,00
190,00
181,00
172,00
164,00
157,00
256,00
248,00
234,00
220,00
208,00
233,00
227,00
215,00
204,00
194,00
184,00
171,00
278,00
217,00
260,00
249,00
239,00
229,00
368,00
358,00
339,00
322,00
306,00
-

1,52
2,16
3,44
4,73
6,01
7,30
9,10
1,73
2,59
4,30
6,01
7,72
9,44
2,02
3,18
5,48
7,78
10,10
2,39
3,56
5,91
8,25
10,60
12,90
16,20
2,65
4,07
6,91
9,75
12,60
15,40
19,40
2,90
4,57
7,91
11,30
14,60
17,90
3,44
5,66
10,10
14,50
19,00
4,11
6,12
10,10
14,20
18,20
22,20
27,80
4,48
6,86
11,60
16,40
21,10
25,90
5,27
8,45
14,80
21,10
27,50
-

75,90
74,90
73,10
71,50
69,90
68,40
66,40
101,00
99,80
97,30
95,10
93,00
91,00
88,20
135,00
133,00
129,00
126,00
122,00
119,00
115,00
138,00
137,00
134,00
131,00
129,00
126,00
123,00
168,00
166,00
162,00
158,00
155,00
151,00
147,00
198,00
196,00
192,00
188,00
185,00
181,00
177,00
262,00
258,00
252,00
246,00
241,00
235,00
228,00
238,00
235,00
230,00
225,00
221,00
217,00
211,00
282,00
279,00
274,00
270,00
265,00
261,00
255,00
375,00
371,00
363,00
355,00
348,00
341,00
332,00

1,52
2,16
3,44
4,73
6,01
7,30
9,10
1,73
2,59
4,30
6,01
7,72
9,44
11,80
2,02
3,18
5,48
7,78
10,10
12,40
15,60
2,39
3,56
5,91
8,25
10,60
12,90
16,20
2,65
4,07
6,91
9,75
12,60
15,40
19,40
2,90
4,57
7,91
11,30
14,60
17,90
22,60
3,44
5,66
10,10
14,50
19,00
23,40
29,60
4,11
6,12
10,10
14,20
18,20
22,20
27,80
4,48
6,86
11,60
16,40
21,10
25,90
32,60
5,27
8,45
14,80
21,10
27,50
33,80
42,70

76,60
76,30
75,60
75,00
74,50
73,90
73,20
102,00
102,00
101,00
100,00
99,20
98,40
97,40
137,00
136,00
135,00
134,00
132,00
131,00
129,00
140,00
139,00
138,00
137,00
136,00
135,00
134,00
170,00
169,00
167,00
166,00
165,00
164,00
162,00
200,00
199,00
197,00
196,00
195,00
194,00
192,00
264,00
263,00
261,00
259,00
257,00
255,00
252,00
240,00
239,00
237,00
235,00
234,00
232,00
230,00
284,00
283,00
282,00
280,00
278,00
277,00
275,00
379,00
377,00
374,00
372,00
369,00
366,00
363,00

1,52
2,16
3,44
4,73
6,01
7,30
9,10
1,73
2,59
4,30
6,01
7,72
9,44
11,80
2,02
3,18
5,48
7,78
10,10
12,40
15,60
2,39
3,56
5,91
8,25
10,60
12,90
16,20
2,65
4,07
6,91
9,75
12,60
15,40
19,40
2,90
4,57
7,91
11,30
14,60
17,90
22,60
3,44
5,66
10,10
14,50
19,00
23,40
29,60
4,11
6,12
10,10
14,20
18,20
22,20
27,80
4,48
6,86
11,60
16,40
21,10
25,90
32,60
5,27
8,45
14,80
21,10
27,50
33,80
42,70

The performance datas are valid for all designs. For exact deliveries as a f unction of the viscosity of the fluid to be pumped (also for other viscosities
than those mentioned above) and the pump speed, please refer to the individual characteristics.
10

VM 617 GB / 11.98

4004

ALLWEILER

Series SN...ER..
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size

Delivery
pressure

SN...

p bar

210-40

210-46

210-54

280-43

280-46

280-54

440-40

440-46

440-52

440-54

5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64

n = 1450 1/min
v = 6 mm 2 /s

v = 40 mm2/s

n =2900 1/min
v = 380 mm2/s

Q
l/min

P
kW

Q
l/min

P
kW

Q
l/min

P
kW

195,00
188,00
174,00
162,00
151,00
244,00
234,00
216,00
199,00
322,00
306,00
277,00
284,00
272,00
250,00
230,00
211,00
324,00
312,00
290,00
270,00
428,00
408,00
373,00
407,00
395,00
373,00
352,00
333,00
517,00
500,00
470,00
441,00
600,00
573,00
524,00
479,00
673,00
646,00
597,00
-

2,52
4,21
7,61
11,00
14,40
2,95
5,08
9,35
13,60
3,66
6,51
12,20
3,73
6,22
11,20
16,20
21,20
4,06
6,88
12,50
18,20
5,00
8,76
16,30
5,34
8,86
15,90
22,90
30,00
6,30
10,80
19,70
28,70
7,10
12,40
22,90
33,50
7,71
13,60
25,40
-

200,00
197,00
191,00
186,00
181,00
176,00
169,00
251,00
246,00
238,00
231,00
224,00
218,00
209,00
333,00
326,00
313,00
302,00
291,00
280,00
293,00
287,00
278,00
269,00
261,00
253,00
242,00
332,00
327,00
317,00
309,00
300,00
292,00
282,00
441,00
433,00
418,00
403,00
390,00
377,00
416,00
410,00
401,00
392,00
383,00
375,00
364,00
529,00
521,00
508,00
496,00
484,00
473,00
457,00
619,00
607,00
586,00
566,00
548,00
530,00
692,00
680,00
659,00
639,00
621,00
603,00
-

2,52
4,21
7,61
11,00
14,40
17,80
22,60
2,95
5,08
9,35
13,60
17,90
22,20
28,10
3,66
6,51
12,20
17,90
23,60
29,30
3,73
6,22
11,20
16,20
21,20
26,20
33,20
4,06
6,88
12,50
18,20
23,80
29,50
37,40
5,00
8,76
16,30
23,80
31,30
38,90
5,34
8,86
15,90
22,90
30,00
37,00
46,90
6,30
10,80
19,70
28,70
37,70
46,60
59,20
7,10
12,40
22,90
33,50
44,10
54,60
7,71
13,60
25,40
37,20
48,90
60,70
-

203,00
201,00
199,00
197,00
196,00
194,00
191,00
254,00
253,00
250,00
247,00
244,00
242,00
239,00
338,00
336,00
331,00
327,00
323,00
319,00
313,00
297,00
295,00
291,00
288,00
285,00
282,00
278,00
336,00
334,00
331,00
327,00
324,00
321,00
317,00
448,00
445,00
439,00
434,00
429,00
424,00
418,00
420,00
418,00
414,00
411,00
408,00
405,00
401,00
534,00
532,00
527,00
522,00
518,00
514,00
508,00
628,00
624,00
616,00
609,00
602,00
595,00
586,00
701,00
697,00
689,00
682,00
675,00
668,00
659,00

2,52
4,21
7,61
11,00
14,40
17,80
22,60
2,95
5,08
9,35
13,60
17,90
22,20
28,10
3,66
6,51
12,20
17,90
23,60
29,30
37,20
3,73
6,22
11,20
16,20
21,20
26,20
33,20
4,06
6,88
12,50
18,20
23,80
29,50
37,40
5,00
8,76
16,30
23,80
31,30
38,90
49,40
5,34
8,86
15,90
22,90
30,00
37,00
46,90
6,30
10,80
19,70
28,70
37,70
46,60
59,20
7,10
12,40
22,90
33,50
44,10
54,60
69,40
7,71
13,60
25,40
37,20
48,90
60,70
77,20

v = 6 mm2/s
Q
l/min
399,00
392,00
378,00
366,00
355,00
343,00
328,00
500,00
490,00
472,00
455,00
439,00
424,00
663,00
647,00
618,00
592,00
566,00
583,00
571,00
550,00
529,00
510,00
492,00
662,00
650,00
629,00
608,00
589,00
571,00
879,00
860,00
825,00
793,00
762,00
830,00
817,00
795,00
775,00
755,00
736,00
711,00
1055,00
1038,00
1007,00
979,00
953,00
927,00
-

v = 40 mm2/s

P
kW

Q
l/min

P
kW

6,66
10,10
16,90
23,70
30,50
37,30
46,80
7,53
11,80
20,30
28,90
37,40
46,00
8,95
14,60
26,00
37,40
48,80
9,94
14,90
24,90
34,90
44,80
54,80
10,60
16,20
27,50
38,80
50,10
61,40
12,50
20,00
35,10
50,10
65,20
14,30
21,40
35,50
49,50
63,60
77,70
97,40
16,20
25,20
43,10
61,10
79,00
96,90
-

404,00
401,00
395,00
390,00
385,00
380,00
373,00
507,00
502,00
495,00
487,00
480,00
474,00
465,00
674,00
667,00
655,00
643,00
632,00
621,00
607,00
592,00
587,00
577,00
568,00
560,00
552,00
541,00
671,00
666,00
656,00
647,00
639,00
631,00
620,00
893,00
884,00
869,00
855,00
842,00
829,00
812,00
838,00
833,00
823,00
814,00
806,00
798,00
787,00
1066,00
1059,00
1046,00
1033,00
1022,00
1010,00
995,00

6,66
10,10
16,90
23,70
30,50
37,30
46,80
7,53
11,80
20,30
28,90
37,40
46,00
57,90
8,95
14,60
26,00
37,40
48,80
60,20
76,10
9,94
14,90
24,90
34,90
44,80
54,80
68,80
10,60
16,20
27,50
38,80
50,10
61,40
77,20
12,50
20,00
35,10
50,10
65,20
80,20
101,00
14,30
21,40
35,50
49,50
63,60
77,70
97,40
16,20
25,20
43,10
61,10
79,00
96,90
122,00

v = 380 mm2/s
Q
l/min
406,00
405,00
403,00
401,00
399,00
398,00
395,00
510,00
509,00
506,00
503,00
501,00
498,00
495,00
680,00
677,00
673,00
668,00
664,00
660,00
655,00
596,00
594,00
590,00
587,00
584,00
581,00
577,00
675,00
673,00
669,00
666,00
663,00
660,00
656,00
899,00
896,00
891,00
885,00
880,00
876,00
869,00
843,00
841,00
837,00
834,00
831,00
827,00
823,00
1072,00
1070,00
1065,00
1060,00
1056,00
1052,00
1046,00

P
kW
6,66
10,10
16,90
23,70
30,50
37,30
46,80
7,53
11,80
20,30
28,90
37,40
46,00
57,90
8,95
14,60
26,00
37,40
48,80
60,20
76,10
9,94
14,90
24,90
34,90
44,80
54,80
68,80
10,60
16,20
27,50
38,80
50,10
61,40
77,20
12,50
20,00
35,10
50,10
65,20
80,20
101,00
14,30
21,40
35,50
49,50
63,60
77,70
97,40
16,20
25,20
43,10
61,10
79,00
96,90
122,00

The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other viscosities than
those mentioned above) and the pump speed, please refer to the individual characteristics.
VM 617 GB/11.98

4005

11

ALLWEILER

Series SN...ER..
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size

Delivery
pressure

SN...

p bar

660-40

660-44

660-46

660-51

660-54

940-42

940-46

940-50

940-54

5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64

n = 1450 1/min
v = 6 mm 2 /s
Q
l/min
632,00
615,00
585,00
558,00
714,00
692,00
651,00
614,00
775,00
752,00
711,00
674,00
908,00
872,00
807,00
1039,00
1003,00
937,00
916,00
887,00
834,00
786,00
1107,00
1077,00
1025,00
976,00
1244,00
1197,00
1113,00
1466,00
1419,00
1335,00
-

P
kW
8,06
13,50
24,40
35,20
8,81
15,00
27,40
39,80
9,31
16,00
29,40
42,80
10,60
18,50
34,40
11,70
20,70
38,70
11,70
19,60
35,50
51,40
13,30
22,80
41,90
60,90
14,60
25,50
47,20
16,50
29,20
54,60
-

v = 40 mm2/s
Q
l/min
643,00
636,00
623,00
611,00
600,00
589,00
574,00
730,00
721,00
703,00
686,00
671,00
656,00
791,00
781,00
763,00
747,00
731,00
716,00
934,00
918,00
890,00
863,00
838,00
1064,00
1048,00
1020,00
994,00
969,00
937,00
924,00
901,00
880,00
860,00
840,00
814,00
1127,00
1114,00
1092,00
1070,00
1050,00
1031,00
1276,00
1256,00
1219,00
1185,00
1153,00
1122,00
1499,00
1478,00
1442,00
1408,00
1375,00
-

P
kW
8,06
13,50
24,40
35,20
46,10
57,00
72,20
8,81
15,00
27,40
39,80
52,10
64,50
9,31
16,00
29,40
42,80
56,10
69,50
10,60
18,50
34,40
50,30
66,20
11,70
20,70
38,70
56,80
74,90
11,70
19,60
35,50
51,40
67,30
83,10
105,00
13,30
22,80
41,90
60,90
80,00
99,00
14,60
25,50
47,20
68,80
90,50
112,00
16,50
29,20
54,60
80,00
105,00
-

n =2900 1/min
v = 380 mm2/s
Q
l/min
649,00
646,00
641,00
637,00
633,00
629,00
623,00
738,00
734,00
728,00
722,00
716,00
710,00
703,00
798,00
795,00
788,00
782,00
776,00
771,00
763,00
946,00
940,00
930,00
920,00
911,00
902,00
890,00
1077,00
1071,00
1060,00
1050,00
1041,00
1032,00
1020,00
947,00
942,00
933,00
926,00
918,00
911,00
901,00
1137,00
1132,00
1124,00
1116,00
1109,00
1101,00
1092,00
1292,00
1285,00
1271,00
1259,00
1247,00
1235,00
1220,00
1515,00
1507,00
1494,00
1481,00
1469,00
1458,00
1442,00

P
kW
8,06
13,50
24,40
35,20
46,10
57,00
72,20
8,81
15,00
27,40
39,80
52,10
64,50
81,80
9,31
16,00
29,40
42,80
56,10
69,50
88,30
10,60
18,50
34,40
50,30
66,20
82,10
104,00
11,70
20,70
38,70
56,80
74,90
92,90
118,00
11,70
19,60
35,50
51,40
67,30
83,10
105,00
13,30
22,80
41,90
60,90
80,00
99,00
126,00
14,60
25,50
47,20
68,80
90,50
112,00
143,00
16,50
29,20
54,60
80,00
105,00
131,00
166,00

v = 6 mm2/s
Q
l/min
1284,00
1267,00
1238,00
1210,00
1184,00
1159,00
1457,00
1435,00
1394,00
1356,00
1320,00
-

P
kW
21,40
32,20
54,00
75,70
97,50
119,00
22,90
35,20
60,00
84,70
110,00
-

v = 40 mm2/s
Q
l/min
1296,00
1288,00
1275,00
1263,00
1252,00
1241,00
1226,00
1473,00
1463,00
1445,00
1429,00
1413,00
1398,00
1378,00

P
kW
21,40
32,20
54,00
75,70
97,50
119,00
150,00
22,90
35,20
60,00
84,70
110,00
134,00
169,00

v = 380 mm2/s
Q
l/min
1301,00
1299,00
1294,00
1289,00
1285,00
1281,00
1276,00
1481,00
1477,00
1470,00
1464,00
1459,00
1453,00
1445,00

P
kW
21,40
32,20
54,00
75,70
97,50
119,00
150,00
22,90
35,20
60,00
84,70
110,00
134,00
169,00

The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other
viscosities than those mentioned above) and the pump speed, please refer to the individual characteristics.
12

VM 617 GB/11.98

4006

ALLWEILER

Series SN...ER..
Performance table Delivery flow Q [1/min] and power absorbed P [kW]
Pump
size

Delivery
pressure

SN...

p bar

1300-38

1300-42

1300-44

1300-46

1300-54

1700-42

1700-46

2200-42

2200-46

2900-40

3600-46

5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64
5
10
20
30
40
50
64

n = 1750 1/min
v = 6 mm 2 /s

v = 40 mm2/s

v = 380 mm2/s

Q
l/min

P
kW

Q
l/min

P
kW

Q
l/min

1096,00
1069,00
1020,00
976,00
933,00
1303,00
1266,00
1200,00
1139,00
1397,00
1360,00
1294,00
1233,00
1522,00
1486,00
1419,00
1358,00
2012,00
1953,00
1848,00
1746,00
1700,00
1619,00
1543,00
2030,00
1985,00
1903,00
1828,00
2280,00
2225,00
2127,00
2035,00
2641,00
2587,00
2488,00
2397,00
3362,00
3285,00
3147,00
3020,00
4207,00
4131,00
3993,00
-

14,50
24,00
42,80
61,60
80,40
16,40
27,60
50,10
72,60
17,20
29,20
53,20
77,30
18,20
31,30
57,40
83,50
22,50
39,90
74,70
22,00
37,00
67,00
97,10
24,40
41,70
76,50
111,00
28,80
48,40
87,50
127,00
31,80
54,40
99,50
145,00
42,80
71,60
129,00
187,00
49,80
85,60
157,00
-

1114,00
1103,00
1082,00
1062,00
1044,00
1026,00
1002,00
1329,00
1312,00
1284,00
1257,00
1232,00
1207,00
1174,00
1423,00
1407,00
1378,00
1351,00
1326,00
1301,00
1548,00
1532,00
1503,00
1476,00
1451,00
1427,00
2053,00
2028,00
1982,00
1939,00
1898,00
1778,00
1758,00
1723,00
1690,00
1658,00
1628,00
1588,00
2062,00
2043,00
2007,00
1974,00
1943,00
1913,00
2318,00
2295,00
2252,00
2212,00
2174,00
2138,00
2089,00
2680,00
2656,00
2613,00
2573,00
2535,00
2499,00
3416,00
3382,00
3322,00
3267,00
3214,00
3163,00
4261,00
4228,00
4167,00
4112,00
4059,00
-

14,50
24,00
42,80
61,60
80,40
99,20
1 26,00
16,40
27,60
50,10
72,60
95,00
118,00
149,00
17,20
29,20
53,20
77,30
101,00
125,00
18,20
31,30
57,40
83,50
110,00
136,00
22,50
39,90
74,70
109,00
144,00
22,00
37,00
67,00
97,10
127,00
157,00
199,00
24,40
41,70
76,50
111,00
146,00
181,00
28,80
48,40
87,50
127,00
166,00
205,00
260,00
31,80
54,40
99,50
145,00
190,00
235,00
42,80
71,60
129,00
187,00
244,00
302,00
49,80
85,60
157,00
229,00
301,00
-

1124,00
1119,00
1111,00
1104,00
1097,00
1091,00
1082,00
1341,00
1335,00
1325,00
1315,00
1305,00
1296,00
1284,00
1435,00
1429,00
1419,00
1409,00
1399,00
1390,00
1378,00
1561,00
1555,00
1544,00
1534,00
1525,00
1516,00
1504,00
2074,00
2064,00
2047,00
2031,00
2016,00
2002,00
1982,00
1793,00
1786,00
1773,00
1761,00
1749,00
1738,00
1723,00
2078,00
2071,00
2057,00
2045,00
2034,00
2023,00
2008,00
2337,00
2328,00
2313,00
2298,00
2284,00
2270,00
2252,00
2699,00
2690,00
2674,00
2659,00
2645,00
2632,00
2614,00
3442,00
3430,00
3408,00
3387,00
3367,00
3349,00
3323,00
4287,00
4275,00
4253,00
4232,00
4213,00
4194,00
4168,00

P
kW
14,50
24,00
42,80
61,60
80,40
99,20
126,00
16,40
27,60
50,10
72,60
95,00
118,00
149,00
17,20
29,20
53,20
77,30
101,00
125,00
159,00
18,20
31,30
57,40
83,50
110,00
136,00
172,00
22,50
39,90
74,70
109,00
144,00
179,00
228,00
22,00
37,00
67,00
97,10
127,00
157,00
199,00
24,40
41,70
76,50
111,00
146,00
181,00
230,00
28,80
48,40
87,50
127,00
166,00
205,00
260,00
31,80
54,40
99,50
145,00
190,00
235,00
298,00
42,80
71,60
129,00
187,00
244,00
302,00
383,00
49,80
85,60
157,00
229,00
301,00
372,00
473,00

The performance datas are valid for all designs. For exact deliveries as a function of the viscosity of the fluid to be pumped (also for other viscosities
than those mentioned above) and the pump speed, please refer to the individual characteristics.
VM 617 GB/11.98

4007

13

ALLWEILER

Series SNH...ER..

Sectional drawing
SNH... - horizontal foot mounted pump, internal ball bearing, with mechanical seal, design U...*)
internal ball bearing, with stuffing box, design U2 *) **)
internal ball bearing, with shaft sealing rings, design U3 *) **)
Design U... with mechanical seal

Section A-B

Section E-F

Design U2
Section C-D

Design U3
Part No.
1
2c
3
4
5
6
7
8c
9
12 c
13 c
19
20
21 c
22 c
23 c
24 c
25 c
26 c
27 c
28 c
32 c
34 c
35
36
38
39
40

14

Denomination
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
shaft sealing housing
pump foot
pump casing cover
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
ball valve

Part-No.
41
42
44
46
47
48
49
51
52
53
54
55
57
79
80
81
83 c
107 c
108
109
110

Denomination
key
spring dowel
lock washer
screw plug
screw plug
stop screw
screw plug (only with design U3)
screw plug
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
hexagon screw
socket head cap screw
spacer ring
supporting washer
support ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw

Design U... with mechanical seal


at pump size 940 to 2200

c spare parts
VM 617 GB/03.01

1000

ALLWEILER

Series SNH...ER..
Sectional drawing

SNH... - horizontal foot mounted pump, external ball bearing, with mechanical seal, design D...*) **) and E...*)
external ball bearing, with stuffing box, design KA2 *) **)

Design D...

Section A-B

Section C-D

Section E-F

Design E...
bearing with grease nipple

Design KA2 (pump size 80 to 2200)


Part-No.
1
2c
3
4
5
6
7
8 c
9
10
12 c
13 c
16
19
20
21 c
22 c
23 c
24 c
25 c
26 c
27 c
28 c
32 c
34 c
35
36
37

Denomination
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
bearing housing
pump foot
pump casing cover
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design E)
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circhp
supporting washer
circlip

VM 617 GB/03.01

1001

Part-No. Denomination
38
stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 2200)
39
hexagon nut
40
ball valve
41
key
42
spring dowel
44
lock washer
46
screw plug
47
screw plug
48
stop screw
49
screw plug
50
lubricating nipple
51
socket head cap screw
52
socket head cap screw
53
socket head cap screw
54
socket head cap screw
55
socket head cap screw
57
hexagon screw
80
spacer ring
81
support ring
82
spring dowel
83 c mechanical seal

* Up to pump size 210 with stud


bolt, part No. 38. Pump size 280
to 2200 with eyelet bolt, part No.
38, and spring dowel, part No. 82
(not shown in the drawing)

Design KA2
at pump size 40

c spare parts

15

ALLWEILER

Series SNF...ER..
Sectional drawing
SNF... - flange mounted pump, internal ball bearing, with mechanical seal, design U... *)
internal ball bearing, with stuffing box, design U2 *) **)
internal ball bearing, with shaft sealing rings, design U3 *) **)
Design U... with mechanical seal

Section A-B

Section E-F

Section C-D
Design U2

Design U3

Part No.
1
2c
3
4
5
7
8c
9
12 c
13 c
19
20
21 c
22 c
23 c
24 c
25 c
26 c
27 c
28 c
32 c
34 c
35
36
38
39
40
41
16

Denomination
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
shaft sealing housing
pump casing cover
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
ball valve
key

Part No.
42
46
47
48
49
51
52
53
54
55
79
80
81
83 c
107 c
108
109
110

Denomination
spring dowel
screw plug
screw plug
stop screw
Screw plug (only with design U3)
screw plug
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
supporting washer
Support ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw

Design U... with mechanical seal


at pump size 940 to 2200

c spare parts
VM 617 GB/03.01

1000

ALLWEILER

Series SNF...ER..

Sectional drawing
SNF... - flange mounted pump, external ball bearing, with mechanical seal, design D... *) **) and E... *)
external ball bearing, with stuffing box, design KA2 *) **)
Design D...

Section A-B

Section E-F

Design E...
bearing with grease nipple

Section C-D

Design KA2 (pump size 80 to 2200)

Part No.
1
2c
3
4
5
7
8c
9
10
12 c
13 c
16
19
20
21 c
22 c
23 c
24 c
25 c
26 c
27 c
28 c
32 c
34 c
35
36
37

Denomination
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
bearing housing
pump casing cover
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design E)
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
circlip

Part No.
38
39
40
41
42
46
47
48
49
50
51
52
53
54
55
80
81
82
83 c

Denomination
stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 2200)
hexagon nut
ball valve
key
spring dowel
screw plug
screw plug
stop screw
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
support ring
spring dowel
mechanical seal

* Up to pump size 210 with stud bolt, part


No. 38. Pump size 280 to 2200 with
eyelet bolt, part No. 38, and spring dowel,
part No. 82 (not shown in the drawing)

Design KA2 at pump size 40

c spare parts
VM 617 GB/03.01

1003

17

ALLWEILER

Series SNS...ER..

Sectional drawing
SNS... - vertical pedestal mounted pump, internal ball bearing, with mechanical seal, design U... *)
internal ball bearing, with stuffing box, design U2 *) **)
internal ball bearing, with shaft sealing rings, design U3 *) **)
Design U... with mechanical seal

Design U2

Section E-F

*) shown to pump size 2200


**) available to pump size 2200

Design U3
Section C-D

Section A-B

Design U... with mechanical seal


at pump size 940 to 2200

Part No.
1
2c
3
4
5
7
8c
9
12 c
13 c
19
20
21 c
22 c
23 c
24 c
25 c

18

Denomination
pump casing
pump casing insert
pump cover, drive side
round pump foot
shaft sealing housing
pump casing cover
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer

Part No.
26 c
27 c
28 c
32 c
34 c
35
36
38
39
40
41
42
45
46
47
48
49

Denomination
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
ball valve
key
spring dowel
lock washer
screw plug
screw plug
stop screw
screw plug (only with design U3)
screw plug

Part No.
51
52
53
54
55
79
80
81
83 c
107 c
108
109
110

Denomination
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
supporting washer
support ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw

c spare parts
VM 617 GB/11.98

1004

ALLWEILER

Series SNS...ER..

Sectional drawing
SNS... - vertical pedestal mounted pump, external ball bearing, with mechanical seal, design ID... *) **) and E... *)
external ball bearing, with stuffing box, design KA2 *) **)
Design D...

Design E..
bearing with grease nipple

Section E-F

*) shown to pump size 2200


**) available to pump size 2200

Design KA2 (pump size 80 to 2200)


Section C-D

Section A-B

* Up to pump size 210 with stud bolt, part


NO. 38. Pump size 280 to 2200 with eyelet
bolt, part No. 38, and spring dowel, part
No. 82 (not shown in the drawing)

Design KA2
at pump size 40

Part No.
1
2c
3
4
5
7
8c
9
10
12 c
13 c
16
19
20
21 c
22 c
23 c

Denomination
pump casing
pump casing insert
pump cover, drive side
round pump foot
bearing housing
pump casing cover
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design E)
valve spring
balance pipe
gasket
gasket
O-ring

VM 617 GB/11.98

1005

Part No.
24 c
25 c
26 c
27 c
28 c
32 c
34 c
35
36
37
38
39
40
41
42
45
46

Denomination
gasket
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
circlip
stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 2200)
hexagon nut
ball valve
key
spring dowel
lock washer
screw plug

Part No.
47
48
49
50
51
52
53
54
55
80
81
82
83 c

Denomination
screw plug
stop screw
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
support ring
spring dowel
mechanical seal

c spare parts
19

ALLWEILER

Series SNE/SNEF...ER..

Sectional drawing
SNE..., SNEF... - cartridge unit pump, internal ball bearing, with mechanical seal, design U... *)
internal ball bearing, with stuffing box, design U2 *) **)
internal ball bearing, with shaft sealing rings, design U3 *) **)
Design U... with mechanical seal
Section E-F

Section A-B

Design U2

Section C-D

Design U3
Part No.
2c
3
5
8c
9
12 c
13 c
19
20
21 c
22 c
24 c
27 c
28 c
32 c
34 c
35
36
38
39
40
41
42
48
49
51
54

20

Denomination
pump casing insert
pump cover, drive side
shaft sealing housing
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
gasket
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
ball valve
key
spring dowel
stop screw
screw plug (only with design U3)
screw plug
socket head cap screw
socket head cap screw

Part No.
55
79
80
81
83 c
107 c
108
109
110

Denomination
socket head cap screw
socket head cap screw
spacer ring
supporting washer
support ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw

Design U3

Design U... with mechanical seal at


pump size 940 to 2200

c spare sparts

VM 617 GB/11.98

1006

ALLWEILER

Series SNE/SNEF...ER..
Sectional drawing

SNE..., SNEF... - cartridge unit pump, external ball bearing, with mechanical seal, design D... *) **) and E... *)
external ball bearing, with stuffing box, design KA2 *) **)
Design D..

Section A-B

Section E-F
Series SNE

Series SNEF

Design E...
bearing with grease nipple

Section C-D

Design KA2 (pump size 80 to 2200)

Part No.
2c
3
5
8c
9
10
12 c
13 c
16
19
20
21 c
22 c
24 c
27 c
28 c
32 c
34 c
35
36
37
38
39
40
41
42
48

Denomination
pump casing insert
pump cover, drive side
bearing housing
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design e)
valve spring
balance pipe
gasket
gasket
gasket
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
circlip
stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 2200)
hexagon nut
ball valve
key
spring dowel
stop screw

VM 617 GB/11.98

1007

Part No.
49
50
51
54
55
80
81
82
83 c

Denomination
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
support ring
spring dowel
mechanical seal
* Up to pump size 210 with stud bolt, part
No. 38. Pump size 280 to 2200 with eyelet
bolt, part No. 38, and spring dowel, part
No. 82 (not shown in the drawing)

Design KA2 at pump size 40

c spare parts

21

ALLWEILER

Series SNGH...ER..
Sectional drawing
SNGH... - horizontal foot mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2
internal ball bearing, with shaft sealing rings, design U3
Design U... with mechanical seal
Section A-B

Section E-F

Section C-D

Design U2

Design U3
Part-No.
1
2c
3
4
5
6
8c
9
12 c
13 c
19
20
21 c
22 c
23 c
24 c
25 c
26 c
27 c
28 c
29 c
32 c
34 c
35
36
38
39
40

22

Denomination
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
shaft sealing housing
pump foot
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer (with pump size 440 to
1300)
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
ball valve

Part-No.
41
42
43
44
46
47
48
49
51
52
54
55
57
79
80
81
83 c
107 c
108
109
110

Denomination
key
spring dowel
screw plug
lock washer
screw plug (with pump size 440 to 1300)
screw plug
stop screw
screw plug (only with design U3)
screw plug
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
hexagon screw
socket head cap screw
spacer ring
supporting washer
support ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw

Design U... with mechanical seal at


pump size 940 to 1300

c spare parts
VM 617 GB/03.01

1008

ALLWEILER

Series SNGH... ER..


Sectional drawing

SNGH... - horizontal foot mounted pump, external ball bearing, with mechanical seal, design D... and E...
external ball bearing, with stuffing box, design KA2
Design D...
Section A-B

Section E-F

Design E...
bearing with grease nipple

Section C-D

Design KA2

Part-No.
1
2c
3
4
5
6
8c
9
10
12 c
13 c
16
19
20
21 c
22 c
23 c
24 c
25 c
26 c
27 c
28 c
29 c
32 c
34 c
35
36
37

Denomination
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
bearing housing
pump foot
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design. E)
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer (with pump size 280 to1300)
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
circlip

VM 617 GB/03.01

1009

Part-No.
38
39
40
41
42
43
44
46
47
48
49
50
51
52
54
55
57
80
81
82
83 c

Denomination
stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 2200)
hexagon nut
ball valve
key
spring dowel
screw plug
lock washer
screw plug (with pump size 440 to 1300)
screw plug
stop screw
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
hexagon screw
spacer ring
support ring
spring dowel
mechanical seal

c spare parts

* Up to pump size 210 with stud bolt, part No.


38. Pump size 280 to 1300 with eyelet bolt,
part No. 38, and spring dowel, part No. 82
(not shown in the drawing)

Design KA2 at pump size 40

23
23

ALLWEILER

Series SNGF...ER..
Sectional drawing
SNGF... - flange mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2
internal ball bearing, with shaft sealing rings, design U3
Design U... with mechanical seal
Section A-B

Section E-F

Design U2

Section C-D

Design U3
Part No.
1
2c
3
4
5
7
8c
9
12 c
13 c
19
20
21 c
22 c
23 c
24 c
25 c
26 c
27 c
28 c
29 c
32 c
34 c
35
36
38
39
40

24

Denomination
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side

Part No.
41
42
43
46

shaft sealing housing


pump casing cover
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer (with pump size 440 to 300)
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
ball valve

47
48
49
51
52
53
54
55
79
80
81
83 c
107 c
108
109
110

Denomination
key
spring dowel
screw plug
screw plug (with pump size 440 to
1300)
screw plug
stop screw
screw plug (only with design U3)
screw plug
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
supporting washer
support ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw

Design U... with mechanical seal


at pump size 940 to 1300

c spare parts
VM 617 GB/11.98

1010

ALLWEILER

Series SNGF...ER..

Sectional drawing
SNGF... -flange mounted pump, external ball bearing, with mechanical seal, design D... and E....
external ball bearing, with stuffing box, design KA2
Design D...
Section A-B

Section E-F

Design E...
bearing with grease nipple

Section C-D

Design KA2

Part No.
1
2c
3
4
5
7
8c
9
10
12 c
13 c
16
19
20
21 c
22 c
23 c
24 c
25 c
26 c
27 c
28 c
29 c
32 c
34 c
35
36
37

Denomination
pump casing
pump casing insert
pump cover, drive side
pump cover, non-drive side
bearing housing
pump casing cover
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design E)
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer (with pump size 440 to 1300)
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
circlip

VM 617 GB/11.98

1011

Part No.
38
39
40
41
42
43
46
47
48
49
50
51
52
53
54
55
80
81
82
83 c

Denomination
stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to
hexagon nut
ball valve
key
spring dowel
screw plug
screw plug (with pump size 440 to
screw plug
stop screw
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
support ring
spring dowel
mechanical seal

* Up to pump size 210 with stud bolt, part


No. 38. Pump size 280 to 1300 with eyelet
bolt, part No. 38, and spring dowel, part
No. 82 (not shown in the drawing)

Design KA2 at
pump size 40

c spare parts
25

ALLWEILER

Series SNGS...ER..

Sectional drawing
SNGS... - vertical pedestal mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2
internal ball bearing, with shaft sealing rings, design U3
Design U2

Design U... with mechanical seal


Section E-F

Design U3

Design U... with mechanical seal


at pump size 940 to 1300

Part No.
1
2c
3
4
5
7
8c
9
12 c
13 c
19
20
21 c
22 c
23 c
24 c
25 c
26 c
27 c

26

Denomination
pump casing
pump casing insert
pump cover, drive side
round pump foot
shaft sealing housing
pump casing cover
balance bush
seal cover
gland (only with design U2)
driving spindle
idler spindle
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer (with pump size 440 to 1300)
joint washer
joint washer

Part No.
28 c
29 c
32 c
34 c
35
36
38
39
40
41
42
43
45
46
47
48
49
51
52

Denomination
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
stud bolt
hexagon nut
ball valve
key
spring dowel
screw plug
lock washer
screw plug (with pump size 440 to 1300)
screw plug
stop screw
screw plug (only with design U3)
screw plug
socket head cap screw
socket head cap screw

Part No.
53
54
55
79
80
81
83 c
107 c
108
109
110
120
121 c
123
124 c
125
127 c

Denomination
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
supporting washer
Support ring (only with design U2)
mechanical seal
shaft seal ring
supporting ring
spacer bush
hexagon screw
heating chamber (intermediary)
gasket
screw plug
joint washer
socket head cap screw
joint washer

c spare parts
VM 617 GB/11.98

1012

ALLWEILER

Series SNGS...ER..

Sectional drawing
SNGS... - vertical pedestal mounted pump, external ball bearing, with mechanical seal, design D... and E...
external ball bearing, with stuffing box, design KA2
Design D...

Section E-F

Design E..
bearing with grease nipple

* Up to pump size 210 with stud bolt, part


No. 38. Pump size 280 to 1300 with eyelet
bolt, part No. 38, and spring dowel, part
No. 82 (not shown in the drawing)

Design KA2

Design KA2
at pump size 40

Part No.
1
2c
3
4
5
7
8c
9
10
12 c
13 c
16
19
20
21 c
22 c
23 c
24 c
25 c

Denomination
pump casing
pump casing insert
pump cover, drive side
round pump foot
bearing housing
pump casing cover
balance bush
gland
greasing chamber disc
driving spindle
idler spindle
spacer bush
labyrinth ring (only with design E)
valve spring
balance pipe
gasket
gasket
O-ring
gasket
joint washer (with pump size 440 to 1300)

VM 617 GB/1198 1013

Part No.
26 c
27 c
28 c
29 c
32 c
34 c
35
36
37
38
39
40
41
42
43
45
46
47
48

Denomination
joint washer
joint washer
joint washer
joint washer
gland packing ring
groove ball bearing
circlip
supporting washer
circlip
stud bolt (with pump size 40 to 210)
eyelet bolt (with pump size 280 to 1300)
hexagon nut
ball valve
key
spring dowel
screw plug
lock washer
screw plug (with pump size 440 to 1300)
screw plug
stop screw

Part No.
49
50
51
52
53
54
55
80
81
82
83 c
120
121 c
123
124 c
125
127 c

Denomination
screw plug
lubricating nipple
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
socket head cap screw
spacer ring
support ring
spring dowel
mechanical seal
heating chamber (intermediary)
gasket
screw plug
joint washer
socket head cap screw
joint washer

c spare parts
27

ALLWEILER

Series SNH...ER..
Pump dimensions - not valid for fabricated (welded) design

SNH... - horizontal foot mounted pump, internal ball bearing, with mechanical seal, design U... *)
internal ball bearing, with stuffing box, design U2 *) **)
internal ball bearing, with shaft sealing rings, design U3 *) **) and U4 *) **)
external ball bearing, with mechanical seal, design D... *) **) and E... *)
external ball bearing, with stuffing box, design KA2 *) **)

Branch position: Suction and


delivery branch opposed in one line
(In-line) on centerline of pump. The
sense of flow may be changed
without alteration of sense of
rotation by turning the pump casing
by 180.

Dimensions in mm
Alteration of dimensions reserved

pump
size
40
80
120
210
280
440
660
940
1300
1700
2200
2900/3600

pump dimensions
h
106
118
150
160
190
200
215
225
240
260
265
315

k1
285
327
411
446
531
580
630
690
760
809
885
1030

k2
393
435
503
580
630
716
800
886
965
1060
1136
1322

n2
162
174
207
217
247
257
307
317
382
402
407
467

foot dimensions

o
189
213
265
285
330
350
380
400
430
470
480
560

q
230
275
317
352
390
440
490
555
570
630
715
820

r
130
155
185
205
220
245
270
290
310
350
360
414

a
70
70
140
140
200
200
200
200
300
300
300
340

b
144
144
180
180
300
300
300
300
370
370
370
420

c
10
10
15
15
30
30
30
30
35
35
35
28

e
114
114
190
190
280
280
280
280
380
380
380
400

shaft end

f
170
170
210
210
350
350
350
350
430
430
430
470

i
193
235
246
281
291
340
390
450
420
469
545
660

s
12,0
12,0
14,5
14,5
24,0
24,0
24,0
24,0
24,0
24,0
24,0
26,0

d
19
19
24
28
32
38
42
48
48
55
60
70

I
29
31
45
53
48
50
65
75
85
95
95
130

t
21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5
59,0
64,0
74,5

u
6
6
8
8
10
10
12
14
14
16
18
20

max. dimension with by-pass valve, may be smaller each acc. to valve type. For return valves see dimension leaflet VM 617 GB/...2008, page 36

pump
size

delivery flange

suction flange
nom. up to DN 150 - PN16 DIN EN 1092-2, form B nom.
diam.
diam.

connections

DNS

g1

y1

z1

DNd

g2

y2

z2

g2

y2

z2

B1/B2

pressure
gauge
E3/E4 M1/M2

32
65
65
80
100
125
125
150
150
200
200
250

140
185
185
200
220
250
250
285
285
340
340
395

100
145
145
160
180
210
210
240
240
295
295
350

19
19
19
19
19
19
19
23
23
23
23
23

100
120
130
150
165
180
195
205
220
240
250
300

18
20
20
22
24
26
26
26
26
26
26
28

4
4
4
8
8
8
8
8
8
8
8
12

25
50
50
65
80
100
100
125
125
150
150
200

115
165
165
185
200
235
235
270
270
300
300
375

85
125
125
145
160
190
190
220
220
250
250
320

14
19
19
19
19
23
23
28
28
28
28
31

100
120
130
150
165
180
195
205
220
240
250
300

18
22
22
24
26
28
28
30
30
34
34
40

4
4
4
8
8
8
8
8
8
8
8
12

140
180
180
205
215
250
250
295
295
345
345
-

100
135
135
160
170
200
200
240
240
280
280
-

18
22
22
22
22
26
26
30
30
33
33
-

106
124
134
152
167
182
197
209
224
242
252
-

24
26
26
26
28
30
30
34
34
36
36
-

4
4
4
8
8
8
8
8
8
8
8
-

G
6
G
G
G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G
G
G
G
G

PN40 DIN EN 1092-2, form B

drainage

PN64 DIN 2546, form B

from DN200 - PN10 DIIN EN 1092-2, form B

40
80
120
210
280
440
660
940
1300
1700
2200
2900/3600

venting

G
G
G
G
G
G
G
G
G
G
G
G

only possible with pump casing in GGG-40 (surplus price).

28

VM 617 GB/1198

2000

ALLWEILER

Series SNF...ER..

Pump dimensions - not valid for fabricated (welded) design


SNF... - flange mounted pump, internal ball bearing, with mechanical seal, design U... *)
internal ball bearing, with stuffing box, design U2 *) **)
internal ball bearing, with shaft sealing rings, design U3 *) **) and U4 *) **)
external ball bearing, with mechanical seal, design D... *) **) and E... *)
external ball bearing, with stuffing box, design KA2 *) **)

Branch position: Suction and


delivery branch opposed in one
line (In-line) on centerline of
pump. The sense of flow may
be changed without alteration of
sense of rotation by turning the
pump casing by 180.

Dimensions in mm
Alteration of dimensions reserved
pump
size
k2
40
393
80
435
120
503
210
580
280
630
440
716
660
800
940
886
1300
965
1700
1060
2200
1136
2900/3600 1322

pump dimensions

n2
o1
q
162
174
207
217
247
257
307
317
382
402
407
467

83
95
115
125
140
150
165
175
190
210
215
245

230
275
317
352
390
440
490
555
570
630
715
820

a1

b1

c1

130
155
185
205
220
245
270
290
310
350
360
414

190
230
260
290
310
360
380
400
410
480
480
560

130
155
185
205
220
250
270
290
310
350
360
450

130
153
163
172
175
208
227
241
259
265
267
287

c3

e1

130
153
175
198
209
234
259
287
307
335
355
400

160
190
220
250
260
310
320
350
360
420
420
500

flange cover

f1
f2
20
21
23
23
27
27
27
31
31
35
35
33

100
106
122
127
146
158
173
175
181
192
198
263

shaft end
i1

s1

y3

y4

z3

130
138
168
181
195
209
239
251
267
288
294
394

13,5
17,5
17,5
17,5
22,0
26,0
26,0
22,0
22,0
22,0
22,0
26,0

14,5
16,5
18,0
20,5
21,5
25,0
25,0
28,0
28,0
28,0
30,0
30,0

5,0
6,0
6,0
5,5
6,0
6,0
6,0
6,0
6,0
6,0
10
6,0

4
4
4
4
4
4
4
8
8
8
8
8

19
19
24
28
32
38
42
48
48
55
60
70

29
31
45
53
48
50
65
75
85
95
95
130

21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5
59,0
64,0
74,5

6
6
8
8
10
10
12
14
14
16
18
20

max. dimension with by-pass valve, may be smaller each acc. to valve type. For return valves see dimension leaflet VM 1617 GB/...2008, page 36
Space to be kept free for assembling.

pump
size

40
80
120
210
280
440
660
940
1300
1700
2200
2900/3600

suction flange

delivery flange

nom. up to DN 150 - PN16 DIN EN 1092-2, form B nom.


diam. from DN 200 - PN10 DIN EN 1092-2, form B diam.

PN40 DIN EN 1092-2, form B

connections
drain- vent- presage
ing
sure
gauge

PN64 DIN 2546, form B

DNS

g1

y1

z1

DNd

g2

y2

z2

g2

y2

z2

B1/B2 E3/E4 M1/M2

32
65
65
80
100
125
125
150
150
200
200
250

140
185
185
200
220
250
250
285
285
340
340
395

100
145
145
160
180
210
210
240
240
295
295
350

19
19
19
19
19
19
19
23
23
23
23
23

100
120
130
150
165
180
195
205
220
240
250
300

18
20
20
22
24
26
26
26
26
26
26
28

4
4
4
8
8
8
8
8
8
8
8
12

25
50
50
65
80
100
100
125
125
150
150
200

115
165
165
185
200
235
235
270
270
300
300
375

85
125
125
145
160
190
190
220
220
250
250
320

14
19
19
19
19
23
23
28
28
28
28
31

100
120
130
150
165
180
195
205
220
240
250
300

18
22
22
24
26
28
28
30
30
34
34
40

4
4
4
8
8
8
8
8
8
8
8
12

140
180
180
205
215
250
250
295
295
345
345
-

100
135
135
160
170
200
200
240
240
280
280
-

18
22
22
22
22
26
26
30
30
33
33
-

106
124
134
152
167
182
197
209
224
242
252
-

24
26
26
26
28
30
30
34
34
36
36
-

4
4
4
8
8
8
8
8
8
8
8
-

G
G
G
G
G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G
G
G
G
G

only possible with pump casing in GGG-40 (surplus price).

VM 617 GB/11.98

2001

29

ALLWEILER

Series SNS...ER..

Pump dimensions - not valid for fabricated (welded) design


SNS... - vertical pedestal mounted pump, internal ball bearing, with mechanical seal, design U... *)
internal ball bearing, with stuffing box, design U2 *) **)
internal ball bearing, with shaft sealing rings, design U3 *) **) and U4 *) **)
external ball bearing, with mechanical seal, design D... *) **) and E... *)
external ball bearing, with stuffing box, design KA2 *) **)
Branch position: Suction and
delivery branch opposed in
one line (In-line) on centerline
of pump. The sense of flow
may be changed without
alteration of sense of rotation
by turning the pump casing by
180.

shaft end all


designs

Sense of rotation:
clockwise seen from
drive side

IEC
size

Standard motors
k5
IEC
k5
appr. size appr.

71
80

240
275
90 S 305
90 L 330
100 L 365
112 M 380
132 S 445
132 M 485
160 M 585
160 L 630
pump dimensions

pump
size
40
80
120
210
280
440
660
940
1300
1700
2200
2900/3600

k6
390,5
464,0
521,5
582,5
741,0
790,0
840,0
925,0
1020
1096
1165
1400

n2
162
174
207
217
247
257
307
317
382
402
407
467

flange cover

o1
83
95
115
125
140
150
165
175
190
210
215
263

q5
160
189
205
230
350
350
350
370
450
466
450
580

a1
190
230
260
290
310
360
380
400
410
480
480
560

b1
130
155
185
205
220
250
270
290
310
350
360
450

c1
130
153
163
172
175
208
227
241
259
265
267
287

c3
130
153
175
198
209
234
259
287
307
335
355
400

e1
160
190
220
250
260
310
320
350
360
420
420
500

max. dimension with by-pass valve, may be 'smaller each acc. to valve type.

40
80
120
210
280
440
660
940
1300
1700
2200
2900/3600

f2
100
106
122
127
146
158
173
175
181
192
198
263

foot dimensions
i1
130
138
168
181
195
209
239
251
267
288
294
394

s1
13,5
17,5
17,5
17,5
22,0
26,0
26,0
22,0
22,0
22,0
22,0
26,0

y3
14,5
16,5
18,0
20,5
21,5
25,0
25,0
28,0
28,0
28,0
30,0
40,0

y4
5,0
6,0
6,0
5,5
6,0
6,0
6,0
6,0
6,0
6,0
10
7,0

z3
4
4
4
4
4
4
4
8
8
8
8
8

a2
250
280
320
340
400
420
480
510
560
600
620
800

c2
22
23
25
25
30
35
35
40
35
35
40
60

e2
220
240
280
300
360
380
440
460
500
540
560
700

s2
14
18
18
18
18
18
18
18
23
23
23
30

650
690
735
810
835
940
1000
1050
1140
1200

shaft end
z4
4
6
6
6
8
8
8
8
8
8
8
8

d
19
19
24
28
32
38
42
48
48
55
60
70

I
29
31
45
53
48
50
65
75
85
95
95
130

t
21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5
59,0
64,0
74,5

u
6
6
8
8
10
10
12
14
14
16
18
20

at SNS 120 with valve DS 38 + DVI38: dimension k 6 = 608,0 and q 5 = 291,5; screw arrangement at foot = IV
at SNS 210 with valve DS 38:
dimension k 6 = 651,0 and q 5 - 298,5; screw arrangement at foot = IV

For return valves see dimension leafiet VM 617 GB/...2008, page 36


Space to be kept free for assembling.

pump
size

f1
20
21
23
23
27
27
27
31
31
35
35
33

180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M

The deviating dimensions as well as the screws of the foot are caused by the necessary intermediary.

suction flange

delivery flange
PN40 DIN EN 1092-2, form B

nom. up to DN 150-PN16 DIN EN 1092-2, form B nom.


diam. from DN 200- PN10 DIN EN 1092-2, form B
diam.

drainage

PN64 DIN 2546, form B

connections
vent- presing
sure
gauge

DNS

g1

y1

z1

DNd

g2

y2

z2

g2

y2

z2

B1/B3 E2/E4 M1/M2

32
65
65
80
100
125
125
150
150
200
200
250

140
185
185
200
220
250
250
285
285
340
340
395

100
145
145
160
180
210
210
240
240
295
295
350

19
19
19
19
19
19
19
23
23
23
23
23

100
120
130
150
165
180
195
205
220
240
250
300

18
20
20
22
24
26
26
26
26
26
26
28

4
4
4
8
8
8
8
8
8
8
8
12

25
50
50
65
80
100
100
125
125
150
150
200

115
165
165
185
200
235
235
270
270
300
300
375

85
125
125
145
160
190
190
220
220
250
250
320

14
19
19
19
19
23
23
28
28
28
28
31

100
120
130
150
165
180
195
205
220
240
250
300

18
22
22
24
26
28
28
30
30
34
34
40

4
4
4
8
8
8
8
8
8
8
8
12

140
180
180
205
215
250
250
295
295
345
345
-

100
135
135
160
170
200
200
240
240
280
280
-

18
22
22
22
22
26
26
30
30
33
33
-

106
124
134
152
167
182
197
209
224
242
252
-

24
26
26
26
28
30
30
34
34
36
36
-

4
4
4
8
8
8
8
8
8
8
8
-

G
G
G
G
G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G
G
G
G
G

leakage
oil
T
G
G
G
G
G
G
G
G
G
G
G
G

only possible with pump casing in GGG-40 (surplus price).

30

VM 617 GB/11 98

2002

ALLWEILER

Series SNE/SNEF...ER..

Pump dimensions - not valid for fabricated (welded) design


SNE..., SNEF... - cartridge unit pump, internal ball bearing, with mechanical seal, design U... *)
internal ball bearing, with stuffing box, design U2 *) **)
internal ball bearing, with shaft sealing rings, design U3 '*) **) and U4 *) **)
external ball bearing, with mechanical seal, design D... *) **) and E... *)
external ball bearing, with stuffing box, design KA2 *) **)
design
U2, U3, U4

design
D..., E...

design
KA2

view X
only with design U4
pump size 40 to 440

shaft end
all desigins

*) shown to pump size 2200 **)


available to pump size 2200

SNEF

Sense of rotation:
clockwise seen
from drive side

z3/z5 = No. of holes


pump
size
40
80
120
210
280
440
660
940
1300
1700
2200
2900/3600

Dimensions in mm
Alteration of dimensions reserved

pump dimensions

mounting flange

i2

r1

r2

r3

y6

y7

a3

e3

s3

s4

yc

z5

145,0
155,0
186,5
207,0
217,0
235,0
265,0
280,0
296,0
317,0
325,0
435,0

375
414
480
555
600
673
770
854
932
1022
1095
1255

81
100
108
126
132
150
168
188
210
232
252
292

85
105
120
140
147
171
191
214
235
261
280
319

86
106
121
141
148
172
192
215
236
262
281
320

66
95
105
113
145
173
193
240
225
267
343
335

12
17
17
18
20
25
28
30
30
30
36
40

12
13
16
16
21
20
20
20
31
30
30
30

128
152
182
203
217
243
266
290
310
348
360
410

105
130
152
175
180
205
230
250
272
300
320
365

12,0
12,0
14,5
14,5
18,5
18,5
18,5
24,0
24,0
24,0
24,0
24,0

M 10
M 10
M 12
M 12
M 16
M 16
M 16
M 20
M 20
M 20
M 20
M 20

14,0
16,5
19,0
21,0
22,5
25,0
28,0
31,0
34,0
34,0
40,0
47,0

6
6
6
6
6
8
8
8
8
8
12
12

stated dimensions without gasket

pump
size
40
80
120
210
280
440
660
940
1300
1700
2200
2900/3600

a1
190
230
260
290
310
360
380
400
410
480
480
560

b1
130
155
185
205
220
250
270
290
310
350
360
450

d
c1
130
153
163
172
175
208
227
241
259
265
267
287

d
c3
130
153
175
198
209
234
259
287
307
335
355
400

flange cover (only with series SNEF...)


d
d
e1
f1
f2
i1
160
20
100
130
190
21
106
138
220
23
122
168
250
23
127
181
260
27
146
195
310
27
158
209
320
27
173
239
350
31
175
251
360
31
181
267
420
35
192
288
420
35
198
294
500
33
263
394

shaft end
s1
13,5
17,5
17,5
17,5
22,0
26,0
26,0
22,0
22,0
22,0
22,0
26,0

y3
14,5
16,5
18,0
20,5
21,5
25,0
25,0
28,0
28,0
28,0
30,0
40,0

y4
5,0
6,0
6,0
5,5
6,0
6,0
6,0
6,0
6,0
6,0
10
7,0

z3
4
4
4
4
4
4
4
8
8
8
8
8

d
19
19
24
28
32
38
42
48
48
55
60
70

I
29
31
45
53
48
50
65
75
85
95
95
130

t
21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5
59,0
64,0
74,5

u
6
6
8
8
10
10
12
14
14
16
18
20

space to be kept free for assembling

VM 617 GB/11.98

2003

31

ALLWEILER

Series SNGH...ER..

Pump dimensions - not valid for fabricated (welded) design


SNGH... - horizontal foot mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2...
internal ball bearing, with shaft sealing rings, design U3 and U4
external ball bearing, with mechanical seal, design D... and E...
external ball bearing, with stuffing box, design KA2

design
U2, U3, U4

design
D..., E...

design
KA2

view X
only with design U4
pump size 40 to 440

shaft end
all designs

Branch position: Suction and


delivery branch arranged one
after the other (U-turn) on
centerline of pump.

Dimensions in mm
Alteration of dimensions reserved
pump
size
40
80
120
210
280
440
660
940
1300

pump
size

40
80
120
210
280
440
660
940
1300

pump dimensions
h
106
118
150
160
190
200
215
225
240

k1
285
327
411
446
531
580
630
690
760

k2
393
435
503
580
630
716
800
886
965

q7
130
160
180
195
220
255
285
290
290

foot dimensions
q9
205,5
233,5
273,0
301,5
322,0
357,0
407,0
419,0
439,0

r
130
155
185
205
220
245
270
290
310

a
70
70
140
140
200
200
200
200
300

b
144
144
180
180
300
300
300
300
370

suction flange
nom.
diam.

Sense of rotation:
clockwise seen
from drive side

Valve dimensions and connections:


for pipeline installation see dimension leaflet VM 617 GB/...2009, page 37

z1/z2 = No. of holes

c
10
10
15
15
30
30
30
30
35

e
114
114
190
190
280
280
280
280
380

shaft end

f
170
170
210
210
350
350
350
350
430

i
193
235
246
281
291
340
390
450
420

s
12,0
12,0
14,5
14,5
24,0
24,0
24,0
24,0
24,0

d
19
19
24
28
32
38
42
48
48

delivery flange

PN16 DIN EN 1092-2, form B

nom.
diam.

PN40 DIN EN 1092-2, form B

DNS

g3

y1

z1

DNd

g3

y2

z2

32
50
65
80
100
125
150
150
150

140
165
185
200
220
250
285
285
285

100
125
145
160
180
210
240
240
240

19
19
19
19
19
19
23
23
23

140
150
170
185
190
200
250
250
250

18
20
20
22
24
26
26
26
26

4
4
4
8
8
8
8
8
8

25
40
50
65
80
100
125
125
125

115
150
165
185
200
235
270
270
270

85
110
125
145
160
190
220
220
220

14
19
19
19
19
23
28
28
28

140
150
170
185
190
200
250
250
250

18
20
22
24
26
28
30
30
30

4
4
4
8
8
8
8
8
8

t
21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5

u
6
6
8
8
10
10
12
14
14

connections

PN 64 DIN 2546, form B c

I
29
31
45
53
48
50
65
75
85

g3

upon request

y2

z2

drainage

venting

pressure
gauge

B3/B4

B8/B9

E6/E7

M1/M2

G
G
G
G
G
G
G
G
G

G
G
G
G
G
-

G
G
G
G
G
G
G
G
G

G
G
G
G

only possible with pump casing in GGG-40 (surplus price).

32

VM 617 GB/11.98

2004

ALLWEILER

Series SNGF...ER..

Pump dimensions - not valid for fabricated (welded) design


SNGF... -flange mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2...
internal ball bearing, with shaft sealing rings, design U3 and UJ4
external ball bearing, with mechanical seal, design D... and E....
external ball bearing, with stuffing box, design KA2
design
U2, U3, U4

design
U...

design
D..., E...

design
KA2
shaft end
all designs

Branch position: Suction and


delivery branch arranged one
after the other (U-turn) on
centerline of pump.

Dimensions in mm
Alteration of dimensions reserved
pump
size
40
80
120
210
280
440
660
940
1300

Valve dimensions and connections:


with built-on pump type see dimension leaflet VM 617 GiB/...2008, page 36
for pipeline installation see dimension leaflet VM 617 GiB/...2009, page 37

z1/z2/z3 = No. of holes

pump dimensions

flange cover

k2

c
n2

o1

q7

q9

a1

393
435
503
580
630
716
800
886
965

162
174
207
217
247
257
307
317
382

83
95
115
125
140
150
165
175
190

130
160
180
195
220
255
285
290
290

205,5
233,5
273,0
301,5
322,0
357,0
407,0
419,0
439,0

130
155
185
205
220
245
270
290
310

190
230
260
290
310
360
380
400
410

b1

d
c1

d
c3

130
155
185
205
220
250
270
290
310

130
153
163
172
175
208
227
241
259

130
153
175
198
209
234
259
287
307

Sense of rotation:
clockwise seen
from drive side
shaft end

e1

d
f1

d
f2

i1

s1

y3

y4

z3

160
190
220
250
260
310
320
350
360

20
21
23
23
27
27
27
31
31

100
106
122
127
146
158
173
175
181

130
138
168
181
195
209
239
251
267

13,5
17,5
17,5
17,5
22,0
26,0
26,0
22,0
22,0

14,5
16,5
18,0
20,5
21,5
25,0
25,0
28,0
28,0

5,0
6,0
6,0
5,5
6,0
6,0
6,0
6,0
6,0

4
4
4
4
4
4
4
8
8

19
19
24
28
32
38
42
48
48

29
31
45
53
48
50
65
75
85

21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5

6
6
8
8
10
10
12
14
14

max. dimension with by-pass valve, may be smaller each ace. to valve type. For return valves see dimension leaflet VM (617 GB/...2008, page 36
Space to be kept free for assembling.

pump
size

40
80
120
210
280
440
660
940
1300

nom.
diam.

suction flange
PN16 DIN EN 1092-2, form B

nom.
diam.

delivery flange
PN40 DIN EN 1092-2, form B
PN 64 DIN 2546, form B e

DNs

g3

y1

z1

DNd

g3

y2

z2

32
50
65
80
100
125
150
150
150

140
165
185
200
220
250
285
285
285

100
125
145
160
180
210
240
240
240

19
19
19
19
19
19
23
23
23

140
150
170
185
190
200
250
250
250

18
20
20
22
24
26
26
26
26

4
4
4
8
8
8
8
8
8

25
40
50
65
80
100
125
125
125

115
150
165
185
200
235
270
270
270

85
110
125
145
160
190
220
220
220

14
19
19
19
19
23
28
28
28

140
150
170
185
190
200
250
250
250

18
20
22
24
26
28
30
30
30

4
4
4
8
8
8
8
8
8

g3

upon request

y2

z2

connections
drainage

pressuregauge

E3/E4

E6/E7

E8/E9

M1/M2

G
G
G
G
G
-

G
G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G
G

G
G
G
G

only possible with pump casing in GGG-40 (surplus price).

VM 617 GB/11.98

2005

33

ALLWEILER

Series SNGS...ER..
Pump dimensions - not valid for fabricated (welded) design

SNGS... - Vertical pedestal mounted pump, internal ball bearing, with mechanical seal, design U...
internal ball bearing, with stuffing box, design U2...
internal ball bearing, with shaft sealing rings, design U3 and U4
external ball bearing, with mechanical seal, design D... and E...
external ball bearing, with stuffing box, design KA2

Branch position: Suction and


delivery branch arranged
superimposed (U-turn) on
centerline of
pump.

shaft end all


designs

Sense of rotation:
clockwise seen
from drive side

screw arrangement at pump


foot for:
II = SNGS 40
IV = SNGS 80 to 210
V = SNGS 280 to 940
VI = SNGS 1300

IEC
size

71
80
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L

z1 /z2 /z3/z4 = No. of holes

Valve dimensions and connections:


with built-on pump type see dimension leaflet VM 617 GB/...2008, page 36
for pipeline installation see dimension leaflet VM 617 GB/...2009, page 37

pump
size
40
80
120
210
280
440
660
940
1300

pump dimensions
c

Dimensions in mm
Alteration of dimensions reserved

flange cover
d
d

Standard motors
k5
k5
IEC
appr. size appr.
240
275
305
330
365
380
445
485
585
630

180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M

foot dimensions

650
690
735
810
835
940
1000
1050
1140
1200

shaft end

k7

n2

o1

q6

q7

a1

b1

c1

c3

e1

f1

f2

i1

s1

y3

y4

z3

a2

c2

e2

s2

z4

451,0
519,5
608,0
651,0
832,0
851,0
916,0
1011
1116

162
174
207
217
247
257
307
317
382

83
95
115
125
140
150
165
175
190

115,5
126,0
155,0
154,0
290,0
239,0
224,0
302,0
387,0

130
160
180
195
220
255
285
290
290

190
230
260
290
310
360
380
400
410

130
155
185
205
220
250
270
290
310

130
153
163
172
175
208
227
241
259

130
153
175
198
209
234
259
287
307

160
190
220
250
260
310
320
350
360

20
21
23
23
27
27
27
31
31

100
106
122
127
146
158
173
175
181

130
138
168
181
195
209
239
251
267

13,5
17,5
17,5
17,5
22,0
26,0
26,0
22,0
22,0

14,5
16,5
18,0
20,5
21,5
25,0
25,0
28,0
28,0

5,0
6,0
6,0
5,5
6,0
6,0
6,0
6,0
6,0

4
4
4
4
4
4
4
8
8

250
280
320
340
400
420
480
510
560

22
23
25
25
30
35
35
40
35

220
240
280
300
360
380
440
460
500

14
18
18
18
18
18
18
18
23

4
6
6
6
8
8
8
8
8

19
19
24
28
32
38
42
48
48

29
31
45
53
48
50
65
75
85

21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5

6
6
8
8
10
10
12
14
14

max. dimension with by-pass valve, may be smaller each acc. to valve type. For return valves see dimension leaflet VM 617 GB/...2008, page 36
Space to be kept free for assemblinig.
pump
size

suction flange

delivery flange

nom.
diam.

PN 16 DIN EN 1092-2, form B

40
80
120
210

DNS
32
50
65
80

A
140
165
185
200

B
100
125
145
160

D
19
19
19
19

g3
140
150
170
185

y1
18
20
20
22

z1
4
4
4
8

DNd
25
40
50
65

E
115
150
165
185

F
85
110
125
145

H
14
19
19
19

g3
140
150
170
185

y2
18
20
22
24

z2
4
4
4
8

280
440
660
940
1300

100
125
150
150
150

220
250
285
285
285

180
210
240
240
240

19
19
23
23
23

190
200
250
250
250

24
26
26
26
26

8
8
8
8
8

80
100
125
125
125

200
235
270
270
270

160
190
220
220
220

19
23
28
28
28

190
200
250
250
250

26
28
30
30
30

8
8
8
8
8

nom.
diam.

PN40 DIN EN 1092-2, form B

connections

PN 64 DIN 2546, form B


E

g3

upon request

y2

z2

drainage
B5
G
G
G
G1
G1
G1
G 1
G 1
G 1

venting
E4
G
G
G
G

E6
G
G
G
G
G
-

pressure
gauge

leakage
oil

M1/M2
G
G
G
G
G
G
G
G
G

T
G
G
G
G
G
G
G
G
G

only possible with pump casing in GGG-40 (surplus price).

34

VM 617 GB / 1198

2006

ALLWEILER

Series SN ...ER..

Heating - not valid for fabricated (welded) design


Series SNH, SNF, SNS, SNGS, design ...E = with heating elements for electrical heating
design ...P = with heating cartridges for steam or heat conveyors
design ...X = with heating cover for steam or heat conveyors

pump
size

40
80
120
210
280
440
660
940
1300
1700
2200
2900/3600

pump dimensions f

heating
steam/heat
conveyor

heating (electrical)

pipe

total heat
capacity
(2 elements)

connec-

key

k7

k8

k9

p4

p5

q6

q7

q8

u1

H1/H2

d1/d2

length

tion

width

451,0
519,5
608,0
651,0
832,0
851,0
916,0
1011
1116
1202
1276
1521

453,5
490,5
589,5
648,5
721,0
777,0
876,0
972,0
1061
1166
1247
1444

413
454
521
604
653
744
825
908
995
1090
1168
1367

223,5
215,5
272,5
296,5
331,0
337,0
386,0
417,0
491,0
536,0
532,0
624,0

183
179
204
252
263
304
335
353
425
460
453
547

115,5
126,0
155,0
154,0
290,0
239,0
224,0
302,0
387,0
-

130
160
180
195
220
255
285
290
290
-

220,5
244,5
291,5
298,5
441,0
411,0
426,0
456,0
546,0
572,0
561,0
701,0

100
120
145
170
175
200
225
244
265
295
310
352

G
G
G
G
G
G
G
G
G
G
G
G

18
18
18
18
18
18
22
22
22
-

240
260
300
420
460
460
680
880
1000
1340
1340
1600

130
150
170
190
210
210
240
250
280
300
300
360

20
20
20
25
25
25
32
40
40
50
50
50

G
G
G
G1
G1
G1
G 1
G 1
G 1
G2
G2
G2

32
32
32
41
41
41
60
60
60
75
75
75

heating elements 2310 V, 50 Hz

heating up time of pump


in minutes at t =

25C 50C 75C 100C

60

120

240

320

f Further dimensions see dimension leaflet VM 617/...2000 for SNH, VM 617/...2001 for SNF, VM 617/...2002 for SNS, VM 611 7/...2006 for SNGS.

VM 617 GB/ 11.98

2007

35

ALLWEILER

Series SN ...ER..
Valve dimensions and connections - not valid for fabricated (welded) design
Pressure relief valves built-on lpumps of series SNH, SNF, SNS, SNGS, SNGF
Valve construction in GG (c.i.) and GGG (s.g.c.i.)

pump
size

SN..

max. permissible
flowworking
through pressure
e
l/min

40

200

80

200
210

120

550
210

210

280

550

bar
0-38
38-58
0-38
38-58
0-38
0-44
0-98
0-38
0-44
0-98
0-13,5
13,5-38

900
0-98
0-13,5
13,5-38

440

900
0-98
0-13,5
13,5-38
900
0-98

660

0-18
1800

0-98
0-13,5
13,5-38

900
0-98

940

0-18
1800

0-98
0-16

1300

2500

1700

2500

0-98
0-16

0-16

2200
2500

2900
3600

36

0-98

0-98
0-9,0

3600

0-98

valve
type
c
DS 3 5 f
DT 35 f
DS 3 5 f
DT 35 f
DS 41
DS 38g
DVI 38g
DS 41
DS 38
DVI 38h
DS 44
DT 44
DV 44
DVI 44
DVS44
DS 44
DT 44
DV 44
DVI 44
DVS44
DS 44
DT 44
DV 44
DVI 44
DVS44
DS 47
DV 47
DVI 47
DS 44
DT 44
DV 44
DVI 44
DVS44
DS 47
DV 47
DVI 47
DS 50
DV 50
DVI 50
DVS50
DS 50
DV 50
DVI 50
DVS50
DS 50
DV 50
DVI 50
DVS50
DS 56
DV 56
DVS56

valve dimensions

design
d
ABfCD
f

bypass
k3

k4

A B C D
- B - D
A B C D

p1

v1

384
384
362
402
384
384
-

v2

n2

pipe thread
n1

PN16
DIN EN 1092-2
n3
DNr

182

155

G1

174

167

G1

20,0 63,5 80,0 111 185

178

G1

44,0 87,5 80,0 121 207

200

G1V2

19,0 69,5 81,0 111 195

188

G1

43,0 93,5 81,0 122 217

210

G1V2

66,0 148 119 167 247

270

65

270

65

280

65

280

65

295

175 210 24,5 49,0 48,5

ABfCD
175 210
f
A B C D 198 245
261 292
A B C D
300 340
A B C D 198 245
261 292
A B C D
300 340
362 410
A B C D
402 450
- B - D

22,0 62,5 51,0

119 j
j
j 66,0 148 119 j 247
360
- 124
410
65,0 148 120 168 257
450
120 j
j
j 65,0 148 120 j 257
360
- 125

362 410
65,0 148 120 168 272
402 450

384 j
120 j
384 j 65,0 148 120 j 272
- 360
- 125
A B C D 400 468 65,0 148 125 193 307

- B - D

65

305

65

360

80

400 468 60,0 195 130 198 317

360

80

A B C D 550 620 100 230 180 250 382


470 j
180 j
- B - D 470 j 100 230 180 j 382
- 530
- 270
A B C D 550 620 89,0 - 191 261 402

385

100

385

100

405

100

405

100

270 407
j
j 407
290

410

100

410

100

295 467

467

125

213 295
467
- 300

467

125

- B - D

700 100

620 700
100
545

19

25

80

305

125 250 210 188

350

4
8
8

620 80,0
j
j 80,0
530

z4

18
22
22

C
D

362 410
60,0 195 125 173 282
402 450

y5

3
3
3

65

A B C D

j
j 402
281

f4

19
19
19

295

80

191
191
200
200
200
213

A
B

350

j
j 89,0
530

470
- B - D 470
A B C D 550
470
- B - D 470
A B C D 620

65

- B - D

65 185 145 122


80 200 160 138
100 220 180 158

DS = Pressure relief valve


with coil spring,
directly operated
DT = Pressure relief valve
with disc springs,
directly operated
DV = Pressure relief valve
directly pilot-operated
DVI = Pressure relief valve
indirectly pilot-operated
DVS = Pressure relief valve
directly pilot-operated,
marine design for
vertical pumps

400 468 65,0 148 125 193 307

384 j
125 j
384 j 80,0 195 125 j 282
- 360
- 130
A B C D 400 468 60,0 195 130 198 317

DNr

- B - D

- B - D

flange dimensions
(back piping connection)
PN16 DIN EN 1092-2, form C

additional dimensions
back piping connections

= by-pass relief valve


= by-pass relief valve
with manual control
= return relief valve
= return relief valve
with manual control

In the case of differential


pressure over 40 bars return
valves (type...C and D...) should
generally be employed.

With pump type SNS 40 and


SNS 80 the valve types DS 35
and DT 35 in design B and D (i.e.
with manual control) are not
possible.

With pump type SNS 120 the


valve type DS 38 and DVI 38 only
with intermediary (between
pump casing and round pump
foot) possible.

With pump type SNS 210 the


valve type DVI 38 only with
intermediary (between pump
casing and round pump foot)
possible.

No dimension because manual


control on opposite adjusting
screw (control acts on pressure
spring).

No dimension because of
lateral adjusting screw.
VM 617 GB/05.00

2008

ALLWEILER

Series SN ...ER..
Valve dimensions and connections
Pressure relief valves for pipe line installation
valve size 23 to 38

valve size 44

valve size 44 to 56

z 4 /z 6 = No. of holes
discharge
flow through

max.
permissible
working
pressure

Dimensions iin mm. Alteration of dimensions reserved

valve
type

design

valve dimensions
material of
casing

connections
inlet (feeding)
nominal
pipe
thread diam. press.

outlet (return)
nominal
pipe
thread diam. press.

from

to

l/min

l/min

bar

n4

n5

DNV

PN

y8

z6

DNr

PN

y5

z4

35

0-38

DS23

EF

GG, GGG, St

110 115 40

35

20

160

0-38

DS29

EF

GG, GGG, St

160 190 62

50

G1

G1

38-58

DT29

EF

GG, GGG, St

160 190 62

50

G1

G1

0-44

DS38

EF

GG, GGG, St

230 260 88

57 G 1

G 1

0-58

DVI38

GG, GGG, St

292

88

57 G 1

G 1

0-98

DVI38

GGG, St

292

88

57

G 1

G 1

0-13,5

DS44

EF

GG, GGG, GS

255 280 78

70

50

40

165 125 18

22

G2

13,5-38

DT44

EF

GG, GGG, GS

300 325 78 70
275 e 78 70
325 e 132 112

50

40

22

G2

50

40

22

G2

50

100

165 125 18
165 125 18
195 145 27

28

50

16

165 125 18

18

355 380 140 130

65

40

185 145 18

24

80

16

200 160 18

24

380 410 160 160

65

40

185 145 18

22

80

16

200 160 18

20

335 e 140 130

65

40

185 145 18

24

80

16

200 160 18

24

St

360 e 160 160

65

40

185 145 18

22

80

16

200 160 18

20

St

360 e 160 160

65

100

220 170 27

30

80

16

200 160 18

20

406 440 150 140

80

40

200 160 18

26

100

16

220 180 18

24

468 500 200 180

80

40

200 160 18

24

100

16

220 180 18

20

320 e 150 140

80

40

200 160 18

26

100

16

220 180 18

24

St

380 e 200 180

80

40

200 160 18

24

100

16

220 180 18

20

230 180 27
235 190 23
235 190 23
265 210 30

32

100

16

220 180 18

20

24

125

16

250 210 18

22

24
36

8
8

125
125

16
16

250 210 18
250 210 18

22
22

8
8

50

100

200

400

600

300

660

1300

2200

3600

l1

0-38

DV44, DVI44

GG, GGG, GS

0-98

DV44, DVI44

St

0-18

DS47

EF

0-38

DV47, DVI47

0-98

DV47, DVI47

0-16

DS50

EF

GG, GGG
St
GG, GGG

GG
St
GG

l2

0-38

DV50, DVI50

0-98

DV50, DVI50

St

380 e 220 180

80

100

0-9

DS56

EF

St

100

40

0-38
0-98

DV56
0V56

F
F

St
St

500 520 220 200


400 e 220 200
395 e 240 200

100
100

40
100

DS = Pressure relief valve with coil spring, directly operated

DT = Pressure relief valve with disc springs, directly operated


DV = Pressure relief valve directly pilot-operated
DVI = Pressure relief valve indirectly pilot-operated
VM 617 GB / 05.00

2009

E = pipe line relief valve without manual control

F = pipe line relief valve with manual control


No dimensiom because of lateral adjusting screw.

37

ALLWEILER

Series SNH...ER..

Installation plan - not valid for fabricated (welded) design


SNH... - horizontal foot mounited pump, internal ball bearing, with mechanical seal, design U... *)
internal ball bearing, with stuffing box, design U2 *) **)
internal ball bearing, with shaft sealing rings, design U3 *) **) and U4 *) **)
external ball bearing, with mechanical seal, design D... *) **) and E... *)
external ball bearing, with stuffing box, design KA2 *) **)
*) shown to pump size 2200
**) available to pump size 2200

Allocation of foundation screws to the base plate sizes

see dimension table of the base plates.


Leakage drain on base plate upon request only.
h 3 = h or h 4 (use max. dimension) + h1
h 4 = size of motor, e.g. 180 M = 180 mm.

Branch position:
Suction and delivery
branch opposed in one
line (In-line) on
centerline of pump.
The sense of flow may
be changed without
alteration of sense of
rotation by turning the
pump casing by 180.

pump
size

connections
drain- ventpresage
sure
ing
gauge

SNH

B1/B2

E3/E4 M1/M2

40
80
120
210

G
G
G
G
G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G
G
G
G
G

280
440
660
940
1300

Valve dimensions and connections:


with built-on pump type see dimension leaflet VM 617 GB/...2008, page 36
for pipeline installation see dimension leaflet VM 617 GB/...2009, page 37
Additional dimensions in case of heating see dimension leaflet VM 617 GB/...2007, page 35
Dimensions in mm
Alteration of dimensions reserved
pump
size

Z1/Z2

= No. of holes

pump dimensions

1700
2200
2900/3600

Sense of rotation:
clockwise seen from
drive side

suction flange

delivery flange

nom. up to DN 150-PN16 DIN EN 1092-2, form B from


DN 200 - PN 10 DIN EN 1092-2, form B
diam.

G
G
G
G
G
G
G
G
G
G
G
G

nom.
diam.

PN 64 DIN 2546, form B h

PN 40 DIN EN 1092-2, form B

k2

n2

p3

DNs

g1

y1

z1

DNd

g2

y2

z2

g2

y2

z2

40
80

106
118

393
435

162
174

189
213

163
160

32
65

140
185

100
145

19
19

100
120

18
20

4
4

25
50

115 85
165 125

14
19

100
120

18
22

4
4

140 100
180 135

18
22

106
124

24
26

4
4

120

150

503

207

265

186

65

185

145

19

130

20

50

165 125

19

130

22

180 135

22

134

26

210

160

580

217

285

228

80

200

160

19

150

22

65

185 145

19

150

24

205 160

22

152

26

280

190

630

247

330

240

100

220

180

19

165

24

80

200 160

19

165

26

215 170

22

167

28

440

200

716

257

350

276

125

250

210

19

180

26

100

235 190

23

180

28

250 200

26

182

30

660

215

800

307

380

310

125

250

210

19

195

26

100

235 190

23

195

28

250 200

26

197

30

940

225

886

317

400

331

150

285

240

23

205

26

125

270 220

28

205

30

295 240

30

209

34

1300

240

965

382

430

395

150

285

240

23

220

26

125

270 220

28

220

30

295 240

30

224

34

1700

260

1060

402

470

430

200

340

295

23

240

26

150

300 250

28

240

34

345 280

33

242

36

2200

265

1136

407

480

421

200

340

295

23

250

26

150

300 250

28

250

34

345 280

33

252

36

2900/3600

315

1322

467

560

502

250

395

350

23

300

28

12

200

375 320

31

300

40

12

max. dimension with by-pass valve, may be smaller each acc. to valve type. For return valves see dimension leaflet VM 617 GB/...2008, page 36
only possible with pump casing in GGG-40 (surplus price).

38

VM 617 GB / 11.98

3000/3001

ALLWEILER

Series SNH...ER..
base plate dimensions

base
plate
size
Gr.

b2

b3

d1

d
d2

h1

h2

l1

foundation screws
allocation

I2

I5

base plate dimensions

base
plate
size

ea.

dimension

Gr.

M 12 x 160
M 12 x 160

10.1
11.1

foundation screws
allocation

d1

d
d2

h1

h2

l1

I2

l3

l4

I5

ea.

dimension

470 510
520 560

18,5
18,5

G
G

87
90

7
7

1120
1250

900
1190

450
595

110
30

6
6

M 16 x 250
M 16 x 250

b2

b3

2
3

265 305
300 340

14,5
14,5

G
G

40
45

25
30

515
575

315 100
355 110

4
4

300 340

14,5

45

30

645

400 122

M 12 x 160

11.4

595 635

18,5

90

1250

1190

595

30

M 16 x 250

5
6

335 379
375 419

18,5
18,5

G
G

50
50

30
30

725
815

500 112
560 127

4
4

M 16 x 160
M 16 x 160

12.1
12.3

575 615
645 685

18,5
18,5

G
G

115
115

8
8

1400
1400

1340
1340

440
440

30
30

8
8

M 16 x 250
M 16 x 250

7.1

320 350

14,5

70

900

630 135

M 12 x 160

13.1

575 615

18,5

115

1600

1540

500

30

M 16 x 250

8.1
9.1

400 430
445 485

14,5
18,5

G
G

72
87

6
7

900 630 135


1000 710 145

4
4

M 12 x 160
M 16 x 250

14.1
16.3

675 715
675 715

18,5
18,5

G
G

115
115

8
8

1600
1800

1540
1740

500
580

30
30

8
8

M 16 x 250
M 16 x 250

17.1

675 715

18,5

120

2000

1940

650

30

M 16 x 250

leakage drain on base plate upon request only.

motor size i

71

80

90 S

90 L

100 L

112 M

132 S

132 M

k5 approx.

265

290

310

335

385

415

475

515

625

0,25 / 0,37

0,37 / 0,55
0,55 / 0,75

0,75
1,1

1,1
1,5

0,75 / 1,1
1,5
2,2 / 3,0

1,5
2,2
4,0

2,2
3,0
5,5

3,0
4,0 / 5,5
7,5

4,0 / 5,5
7,5
11,0

0,37 / 0,55

0,75 / 1,1

1,5

2,2

3,0

4,0

5,5 / 7,5

11,0/15,0

750 1/min
kW 1000 1/min
at = 1500 1/min
3000 1/min
pump size

160 M

required base plate and coupling/dimension xH or xv


xH

Gr

Ku

xH

Gr

Ku

xH

Gr

Ku

xH

Gr

Ku

xH/xV

Gr

Ku

xH/xV

Gr

Ku

xH/xv

Gr

Ku

xH/xV

Gr

Ku

xH/xV

Gr

Ku

SNH 40
SNH 80
SNH 120

35 H
-

2
-

28
-

45 H
60 H
10 H

3
4
5

28
28
28

45 H
60 H
10 H

3
4
5

28
28
28

45 H
60 H
10 H

3
4
5

28
28
28

60 H
50 H
25 H

4
5
6

28
28
28

60 H
50 H
25 H

4
5
6

28
28
28

50 H
60 H
25 H

5
6
6

38
38
38

50 H
60 H
25 H

5
6
6

38
38
38

55 H
80 H
50 H

6
8.1
9.1

42
42
42

SNH 210
SNH 280
SNH 440

25 H
-

6
-

28
-

25 H
-

6
-

28
-

40 H
10 V

7.1
8.1

28
38

7.1
8.1

28
38

38
38

38

9.1

38

9.1

38

40 H
0
0

8.1
9.1

9.1

40 H
0
0

8.1
9.1

10 V

40 H
10 V
10 V

38
38
38

50 H
35 V
35 V

9.1
10.1
10.1

42
42
42

SNH 660
SNH 940
SNH 1300

35 V
-

10.1 42
-

35 V
35 V
-

10.1 42 165 V 11.1


10.1 48 130 V 11.1
- 230 V 12.1

42
48
48

SNH 1700

motor size i

200 L

225 S

200 V 12.1

55

250 M

160 L

180 M

k5 approx.

670

700

730

790

830

750 1/min
kW 1000 1/min
at = 1500 1/min
3000 1/min

7,5
11,0
15,0

18,5

11,0
15,0
22,0

15,0
18,5 / 22,0
30,0

18,5
37,0

22,0
30,0
45,0

30,0
37,0
55,0

18,5

22,0

30,0 / 37,0

45,0

55,0

pump size

180 L

9.1

225 M
875

960

required base plate and coupling/dimension xH or xv


xH/xV

Gr

Ku

xH/xV

Ku

XH/xV

Ku

xH/xV

Ku

xV

Gr

Ku

xV

Gr

Ku

xV

Gr

Ku

xV

Gr

Ku

xV

Gr

Ku

SNH 80
SNH 120
SNH 210

80 H
50 H
50 H

8.1
9.1
9.1

42
42
42

90 H
50 H
15 H

9.1 48
9.1 48
10.1 48

50 H
15 H

9.1 48
10.1 48

90 H
15 H
15 H

9.1 55
10.1 55
10.1 55

150 V

11.1 60

150 V

11.1 60

80 V 11.1 55
90 V 11.1 55

90 V

11.4

60

SNH 280

35 V 10.1 42

35 V

10.1 48

35 V

10.1 48

215 V

11.1 55

175 V

11.1 60

175 V

11.1 60

175 V 11.1 55

160 V 12.1 65

160 V

12.1

60

SNH 440
SNH 660
SNH 940

35 V 10.1 42
165 V 11.1 42
130 V 11.1 48

170 V 11.1 48
165 V 11.1 48
130 V 11.1 48

170 V 11.1 48
165 V 11.1 48
130 V 11.1 48

170 V
125 V
170 V

11.1 55
11.1 55
12.1 55

120 V
190 V
140 V

11.1 60
12.1 60
12.1 60

120 V 11.1 60
190 V 12.1 60
140 V 12.1 60

120 V 11.1 55
190 V 12.1 55
140 V 12.1 55

210 V 12.1 65
160 V 12.1 65
105 V 12.1 65

210 V
160 V
105 V

12.1
12.1
12.1

60
60
60

SNH 1300

230 V 12.1 48

230 V 12.1 48

230 V 12.1 48

190 V

12.1 55

160 V

12.1 60

160 V 12.1 60

160 V 12.1 55

230 V 13.1 65

230 V

13.1

60

SNH 1700
SNH 2200

200 V 12.1 55
-

160 V 12.1 55
200 V 13.1 60

160 V 12.1 55
200 V 13.1 60

260 V
200 V

13.1 55
13.1 60

250 V
180 V

13.1 60
13.1 60

250 V 13.1 60
180 V 13.1 60

250 V 13.1 55
-

200 V 13.1 65
140 V 13.1 65

200 V
-

13.1
-

60
-

290 V 16.3 75

290 V 16.3 75

290 V

16.3 75

290 V

16.3 75

290 V 16.3 75

360 V 17.1 75

SNH 2900/3600

Gr

Gr

Gr

.
motor size i

280 S

280 M

315 S

315 M

k5 approx.

1020

1064

1130

1200

750 1/min
kW 1000 1/min
at = 1500 1/min
3000 1/min
pump size

37,0
45,0
75,0

45,0
55,0
90,0

75,0

ber 315 M
-

55,0
75,0
110,0

75,0
90,0
132,0

90,0

110,0

132,0

required base plate and coupling/dimension xv


Ku

xV

Gr

Ku

SNH 280
SNH 440
SNH 660

xV

135 V 12.3 75
150 V 14.1 75

Gr

Ku

140 V 12.3 65
135 V 12.3 65
150 V 14.1 65

xV

135 V 12.3 75
150 V 14.1 75

140 V 12.3 65
135 V 12.3 65
150 V 14.1 65

150 V 14.1 85

150 V
150 V

14.1 65
14.1 65

SNH 940

170 V 14.1 75

170 V 14.1 65

170 V 14.1 75

170 V 14.1 65

110 V 14.1 85

110 V

14.1 65

SNH 1300
SNH 1700
SNH 2200

180 V 14.1 75
160 V 14.1 75
190 V 16.3 75

180 V 14.1 65
160 V 14.1 65
-

180 V 14.1 75
160 V 14.1 75
190 V 16.3 75

180 V 14.1 65
160 V 14.1 65
-

190 V 16.3 85
235 V 16.3 85
250 V 17.1 85

190 V
235 V
-

16.3 65
16.3 65
-

SNH 2900/3600

300 V 17.1 75

285 V 17.1 85

Gr = base plate size up to 6 of cast iron,


from 7.1 onwards of fabricated steel
Ku = coupling size Polynorm A

Gr

Ku

xV

Gr

Ku

300 V 17.1 75

xV

Gr

Ku

xV

Gr

Ku

xV

Gr

xV

Ku

xV

Gr

Ku

150 V 14.1 75
150 V 14.1 75

j
j
j

j
j
j

j
j
j

110 V 14.1 85

110 V 14.1 75

190 V 16.3 85
235 V 16.3 85
250 V 17.1 85

190 V 16.3 75
235 V 16.3 65
-

j
j
j

j
j
j

j
j
j

285 V 17.1 85

Gr

Three-phase A.C. Standard motors construction IM B3 and enclosure higher than IP 23.
In case of three-phase A.C. Standard motors with enclcosure IP 23 as well as motor sizes above
315 M and D.C. motors dimensions of base plate and ctoupling upon request.
upon request.

39

ALLWEILER

Series SNF...ER..

Unit dimensions - not valid for fabricated (welded) design


SNF... - flange mounted pumip, internal ball bearing, with mechanical seal, design U... *)
internal ball bearing, with stuffing box, design U2 *) **) internal ball
bearing, with shaft sealing rings, design U3 *) **) and U4 *) **) external ball
bearing, with mechanical seal, design D... *) **) and E... *) external ball
bearing, with stuffing box, design KA2 *) **)

Branch position: Suction and


delivery branch opposed in
one line (In-line) on centerline
of pump.

standard motors
k5
IEC
k5
IEC
size appr size appr.

The sense of flow may be


changed without alteration of
sense of rotation by turning
the pump casing by 180.

Valve dimensions and connections:


with built-on pump type see dimension leaflet VM 617 GB/...2008, page 36
for pipeline installation see dimension leaflet VM 617 GB/...2009, page 37
Additional dimensions in case of heating see dimension
leaflet VM 617 GB/...2007, page 35

Dimensions in mm
Alteration of dimensions
reserved

z1 / z2 = No. of holes

pump
size
40
80
120
210
280
440
660
940
1300
1700
2200
2900/3600

foot dimensions

pump-/unit dimensions

240
275
305
330
365
380
445
485
585
630

180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M

650
690
735
810
835
940
1000
1050
1140
1200

shaft end

a1

i1

190
230
260
290
310
360
380
400
410
480
480
560

180
180
195
210
220
280
290
310
310
340
340
e

130
138
168
181
195
209
239
251
267
288
294
394

k0

k2

459,5 393
498,0 435
558,0 503
633,0 580
680,5 630
778,5 716
865,0 800
950,0 886
1015,5 965
1121,0 1060
1197,0 1136
e
1325

n2

o1

162
174
207
217
247
257
307
317
382
402
407
467

83
95
115
125
140
150
165
175
190
210
215
263

230
275
317
352
390
440
490
555
570
630
715
820

130
155
185
205
220
245
270
290
310
350
360
414

128,0
168,0
182,0
195,0
225,5
272,5
295,0
344,0
345,5
381,0
466,0
e

140
140
160
180
185
190
220
235
235
270
270
e

170
250
250
250
250
355
355
355
355
355
355
e

33
40
40
40
40
40
40
40
40
40
40
e

207
315
315
315
315
410
410
410
410
410
410
e

57
60
60
60
60
80
80
80
80
80
80
e

11
18
18
18
18
23
23
23
23
23
23
e

19
19
24
28
32
38
42
48
48
55
60
70

29
31
45
53
48
50
65
75
85
95
95
130

21,5
21,5
27,0
31,0
35,0
41,0
45,0
51,5
51,5
59,0
64,0
74,5

6
6
8
8
10
10
12
14
14
16
18
20

Only valid for three-phase A.C. stanidard motors with enclosure

max. dimension with by-pass valve, may be smaller each acc. to valve type.

higher than IP 23. In case of three-phase A.C. standard motors


with enclosure IP 23 and for D.C. motors dimensions upon request.

pump
size

Sense of rotation:
clockwise seen
from drive side

71
80
90 S
90 L
100 L
112 M
132 S
132 M
160 M
160 L

suction flange

For return valves see dimension leaflet VM 617 GB/...2008, page 36

upon request only.

delivery flange
PN 40 DIN EN 1092-2, form B
PN 64 DIN 2546, form B

nom. up to DN 150- PN 16 DIN EN 1092-2, form B nom.


diam.
diam.
from DN 200-PN 10 DIN EN 1092-2, form B

drainage

connections
ventpresing
sure
gauge

B1/B2 E3/E4 M1/M2

leakage
oil

DNS

g1

y1

z1

DNd

g2

y2

z2

g2

y2

z2

40
80
120
210
280
440
660
940

32
65
65
80
100
125
125
150

140
185
185
200
220
250
250
285

100
145
145
160
180
210
210
240

19
19
19
19
19
19
19
23

100
120
130
150
165
180
195
205

18
20
20
22
24
26
26
26

4
4
4
8
8
8
8
8

25
50
50
65
80
100
100
125

115
165
165
185
200
235
235
270

85
125
125
145
160
190
190
220

14
19
19
19
19
23
23
28

100
120
130
150
165
180
195
205

18
22
22
24
26
28
28
30

4
4
4
8
8
8
8
8

140
180
180
205
215
250
250
295

100
135
135
160
170
200
200
240

18
22
22
22
22
26
26
30

106
124
134
152
167
182
197
209

24
26
26
26
28
30
30
34

4
4
4
8
8
8
8
8

G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G

G
G
G
G
G
G
G
G

1300
1700
2200
2900/3600

150
200
200
250

285
340
340
395

240
295
295
350

23
23
23
23

220
240
250
300

26
26
26
28

8
8
8
12

125
150
150
200

270
300
300
375

220
250
250
320

28
28
28
31

220
240
250
300

30
34
34
40

8
8
8
12

295
345
345
-

240
280
280
-

30
33
33
-

224
242
252
-

34
36
36

8
8
8

G
G
G
G

G
G
G
G

G
G
G
G

G
G
G
G

only possible with pump casing in GGG-40 (surplus price).

40

VM 617 GB / 11.98

3002

Series SN

ALLWEILER

41

Series SN

42

ALLWEILER

Series SN

ALLWEILER

43

Series

ALLWEILER

Subject to technical alterations.


The mentioned performance data are to be considered as a product and performance abstract only. The particular operating limits can be taken from the
quotation or order acknowledgement.

ALLWEILER AG
Postfach 1140 78301 Radolfzell
Allweilerstr. 1 78315 Radolfzell
Germany
Tel. + 49 (0)7732 86-0
Fax. + 49 (0)7732 86-436
E-Mail: [email protected]
Internet: http://www.allweiler.com
VM 617 GB / 07.06 - Ident No. 795 568