Q u a r t e r Tu r n

Electric
Actuators

A101/04

uarter-turn actuators are used to operate ball, plug or butterfly valves, dampers, vents and any
equipment with quarter-turn or part turn travel.

BERNARD has archieved an excellent reputation over the years in this market thanks to a range of
actuators providing the following features :

Compact construction with a high output torque

Self-locking gear train maintains the position of the valve when the actuator is de-energized

Very good resistance to vibrations

Adjustable mechanical travel limit stops prevent overtravel

Emergency handwheel and mechanical position indicator provided on all actuators as a standard

Fixing flange according to ISO standard

Removable drive socket for easy machining

BERNARD actuators have been operated in different fields such as power plants, industry and
building automation, ship building and water treatment.

ON - OFF :
The ON-OFF version of the SD range actuators are designed to fully open or close on an average of
20 to 30 times per day.

CLASS III MODULATING :


With the Class III modulating actuators, it is possible to select between intermediate positions, average of 360 times per day, with a precision better than 2%.
For higher duty and precision modulating actuators, please refer to our modulating range catalog.

WATERPROOF DESIGNS :
As a standard, our SD actuators have a waterproof enclosure IP67 (NEMA 4) as per CEI 144 recommendations.
Higher levels of protection are available on request (please consult us).

CORROSION RESISTANT DESIGNS :


Our actuators can also be manufactured for operation in harsh environmental conditions such as :
industrial corrosive atmosphere (chemical, alumina plants i.e)
marine corrosive atmosphere (on-shore and off-shore)

EXPLOSION-PROOF DESIGNS :
Actuators are also available with an explosion-proof protection complying with the ATEX European
Directive (for detailed specifications, refer to the Technical Guide AF_XTEC101).

Available versions :
Our explosion-proof actuators are available in 2 different designs :
EEx ed design for the explosion-proof versions of the OA, AS and BS actuators
EEx d rating for the UX actuators (complete explosion-proof enclosure)
The EEx d version is recommended for the actuators equipped with an electronic control device such
as a transmitter or Integral+ control. In fact, the circuit boards can be simply and directly fitted into the
EE x d enclosure.

TRANSMISSION GEARS
The gear drive system is composed of 2 reduction stages :
The first stage, driven directly by a pinion on the motor
drive shaft, is a planetary system.
The second stage, driven by the satellite wheels of
the planetary gear consists of a worm and wheel
gear type.
Since the planetary system permits a high speed reduction with an excellent efficiency, the subsequent gear is
driven at a relatively low speed which ensures a better overall efficiency than normal standard gear
designs.

EMERGENCY HANDWHEEL
In case of a loss of power supply or a faulty control system, the presence of a handwheel enables
the operator to easily drive the valve to any required position manually.

MECHANICAL STOPS
BERNARD actuators are equipped with mechanical stops to prevent overtravel, which may occur
during manual operation.

POSITION INDICATOR
A visual position indicator allows for a clear indication of the current valve position. In fact, this indicator is mechanically linked to the valve shaft.

TRAVEL LIMIT SWITCHES


Thanks to the BERNARD camblock system, the adjustment of travel limit switches is simply accomplished with
a standard screwdriver. No disassembly is required.
Each single cam can be set independently from the others.
The cams are automatically locked in their respective
positions, once adjusted, and unaffected by vibrations.

ASYNCHRONOUS MOTORS
The asynchronous motor technology offers the highest ratio of starting torque
versus nominal torque. Thus, the actuator maximum torque capacity is available
from the beginning of travel to unseat the valve.

5
MOTOR THERMAL PROTECTION
A built-in motor thermal switch protects the motor from excessive overheating
conditions.

TORQUE SENSORS
The output torque for valve operation is permanently measured by the lever deflection of the planetary gear external crown. This crown gear is maintained in position by two calibrated linear springs
which can be set independently for each rotational direction to a desired torque value.
In the event the torque setting is reached, the crown lever compresses the spring to a point where
a microswitch is tripped.
As this unique system is mechanically friction-free, exceptional precision and repeatability are
obtained, which is highly appreciated when the device has to "close on torque".

DETACHABLE DRIVE BUSH


The output drive socket can be easily removed from the actuator, without the use of any special tool,
for adaptation to the valve shaft.

LIFETIME LUBRICATION
The gear design permits lifelong lubrication by grease, thus reducing periodic maintenance requirements considerably.

Whether you decide to design your own external control system or to get a turnkey solution, with an
analog or fieldbus technology, review our range of controls and find the most appropriate solution for
your application.

STANDARD VERSION

Actuator

Your control system receives all


basic information from the actuator
(travel limit switches, thermal protection, torque limit switches).
Your control system will have to
integrate the control logic, the
power switches and the maintaining torque limiter signal.

This solution is particularly well


suited for
straight forward
processes and extreme environmental conditions (nuclear application, extreme temperature, high
vibration level,...).

Motor

Control station

Power
supply
Control
logic

Information

PRE-WIRED VERSION (SINGLE PHASE OA ONLY)


Single phase OA actuators can be
delivered with a ready-to-use
internal pre-wiring.
In this configuration, opening and
closing commands can be performed by simple contact (*)
switches. In fact, end of travel and
thermal protection switches are
pre-wired to the motor at the factory.
(*) Contacts used shall withstand the motor maximum
power supply current.

POSITION FEEDBACK POTENTIOMETER / TRANSMITTER


If positioning of the motorised device has to be reported to the control
room, two optional devices can be fitted to our actuators :
a 1 kOhm potentiometer
a 0/4 to 20mA transmitter (TAM)

Control
system

MINIGRAL+ / MINIGAM+ CONTROLS


These electronic boards are designed to control
small BERNARD single phase actuators
Thanks to the Minigral+ and Minigam+ controls
solution, time and money are saved on the design
and wiring of the control logic and power switches
With their very compact design, the boards are
directly mounted into the actuator body thus
requiring no additional external box
Available in two versions :
Minigral+ : on-off operation
Minigam+ : Class III modulating operation

For details refer to MINIGAM+ / MINIGRAL+ catalog


nA112

INTEGRAL+ / POSIGAM+ CONTROLS


More sophisticated than the Minigam+
and Minigral+ electronics, the Integral+
allows full control of both single and
three phase actuators, and provides
additional major advantages such as :
User configuration
Signalling and fault reporting
Device protection functions
Management of specific operation
constraints (for example, close on
torque and valve un-seat)
Emergency Shut Down command

Local / Remote

7
Actuator
Control
logic

Motor

Local keypad controls available


The Integral+ electronics offer some
clear benefits :
real cost and time savings during
the design and wiring phase
additional flexibility and ease during
the start-up phase
Available in two versions :
Integral+ : on-off operation
Posigam+ : Class III modulating
operation

For details refer to INTEGRAL+


POSIGAM+ catalog nA115

Power
supply
Control
panel

Control station

Information

FIELDBUS
BERNARD actuators with INTEGRAL+ controls can be equipped with digital FIELDBUS communication systems :
PROFIBUS DP
DS100/DS200 fully redundant bus system
Other bus technologies : please consult us

Model OA
Small direct quarter turn
actuator for torques lower than
150 N.m
(1,350 In.Lbs)

8
Models
AS18 to 80 & BS
Compact direct quarter turn
actuators for the torque range
150 to 800 N.m
(1,350 to 7.100 In.Lbs)

Models
AS100 to 400
Combination quarter turn
actuators
for torques exceeding
800 N.m
(7,100 In.Lbs)

Note : This table is given for information only. Additional and more detailed data can be found in our
Technical handbooks ref. AF_WTEC101 (weatherproof) and AF_XTEC101 (explosion-proof) such as
torques, 90 travel time, motor data, ...).
Max. Torque
N.m
Lb.ft

Model
IP67

Available design
EEx e d
EEx d

35

25

OA3

60

40

OA6

100

70

OA8 / OAP

150

110

OA15

200

140

AS18
UX18

AS25
UX25

AS50
UX50

AS80
UX80

300

600

800

220

440

590

X
X
X
X
X
X
X

1,000

740

AS100

1,200

890

BS100

1,500

1,110

BS150

2,500

1,840

AS200

4,000

2,950

AS400

ST range
Multi-turn intelligent actuators
Catalog n A114

Modulating range
High duty & precision actuators
Catalog n A103

FQ range
Failsafe spring-return actuators
Catalog n A105

GENERAL

MOTORS

Basic actuators include motor with thermal protection,


gear case, emergency handwheel, connection box,
travel limit switches, torque switches (except for OA)
and output drive with removable socket.

3-Phase squirrel cage induction type TENV


equipped with embedded thermal protection available in all standard voltages 50 or 60 Hz.
1-Phase squirrel cage induction type TENV motor
available in all standard voltages 50 or 60Hz
Motors are easily removable with front and rear
totally enclosed lubricated ball bearings
Motors rated to S4 service (intermittent duty with
starting under load) according to IEC 34-1
Duty rating :
30% and up to 360 Starts / hour for ONOFF service
50% and up to 1200 starts / hour for modulating Class III

TORQUE AND 90 TRAVELLING TIME


Easy overview of torques on page 9 of this catalog.
Detailed data in technical handbooks ref.
AF_WTEC 101 (weatherproof) and AF_XTEC 101
(explosion-proof).

ENCLOSURES
Aluminium die casting
IP67 (IP68, please consult us)
NEMA 4, 4X & 6 C.S.A. NTL certified

10

EX-PROOF VERSIONS
All our SD range explosion-proof actuators comply with
the CE ATEX directive and are suitable for use in zones
1 and 2 (gaseous atmosphere), 21 and 22 (combustible dust).
Construction rating :
Models OA, AS & BS : EEx ed II B T5
Available on request : EEx ed II C T5 or T6
Model UX : EEx d II B T4
Available on request : EEx d II C T4, T5 or T6
For detailed Ex-proof quarter-turn actuators specifications, please refer to the SD Range Explosion-proof
technical handbook AF_XTEC101.

GEAR DESIGN
Two reduction stages :
Planetary system with high speed reduction and excellent efficiency
Oversized worm & quadrant gear type
The gears are mechanically irreversible

MANUAL EMERGENCY OPERATION


Actuators are fitted with a handwheel for manual emergency operation.
On models with torque higher than 800 Nm (1,400
in.lbs), a declutchable handwheel is used with electric
operation priority.

VISUAL POSITION INDICATION


A dial type window provides continuous position indication even in the event of power supply loss.

EXTERNAL CORROSION PROTECTION


Paint system :
Zinc rich primer + epoxy intermediate coat
Optional polyurethane finish
Protection for highly corrosive conditions
on request
All cover fasteners captive and stainless

AMBIENT TEMPERATURE RANGE


IP67 standard :
IP67 low temp. :
IP67 high temp. :

-20 ... +70C / -4 ... +158F


-40 ... +70C / -40 ... +158F
+0 ... +90C / +32 ... +194F

EEx versions : see technical handbook AF_XTEC101.

POSITION AND TORQUE SENSORS


Information sources :
Position : helical reduction gear on main
worm
Torque (not available on OA models) : the
actual actuator torque is measured by the
dynamometric balance principle. Action is
not maintained after the motor is stopped.
Torque springs are calibrated at the manufacturing plant.
Signalling and setting :
Both torque and position limits are indicated by SPDT switches, that can be set independantly for each direction of rotation.

Adjustment is possible at any point of the setting range and does not require any special
tooling.
SPDT switches : 250VAC-16A / 24VDC-16A /
48VDC-2.5A maximum (resistive load).
Options :
Proportional position feedback signal can be
delivered from a 1 kOhm potentiometer or a
0/4-20mA transmitter (TAM)
Intermediate positions by extra switches

TERMINAL COMPARTMENT
Screw-type terminals size 4 mm for controls and
power supply
Internal earth grounding post (internal and external
earth post for explosion-proof design)
Double sealing : In Integral+ version the terminal
compartment can be isolated from the control chamber

CONDUIT ENTRIES (STANDARD VERSION)


Weatherproof
EEx e d
EEx d

: 2 x M 20 (max : 4 x M20)
: 3 x M 20 (max : 4 x M20)
: 2 x 3/4"NPT (max : 3 x 3/4"NPT)

CONTROLS
STANDARD : all control elements are directly connected to screw type terminals according to wiring
diagram S50000.
MINIGRAL+ (option) : integrated controls of on-off
small single phase actuators
(for details refer to MINIGRAL+ catalog nA112)
MINIGAM+ (option) : integrated controls of Class III
modulating small single phase actuators
(for details refer to MINIGAM+ catalog nA112)
INTEGRAL+ (option) : advanced integrated controls
of on-off single and three phase actuators
(for details refer to INTEGRAL+ catalog nA115)
POSIGAM+ (option) : advanced integrated controls
of Class III modulating single and three phase actuators
(for details refer to POSIGAM+ catalog nA115)

11
Please refer to the SD Range Technical handbooks ref AF_WTEC 101 (weatherproof) or AF_XTEC
101 (explosion-proof) for detailed :
Performance data
Dimensional drawings
Wiring diagrams

Note : This brochure is not intended to form the basis of a contract and the company reserves the right
to amend the design and specifications without notice.