Earthing Calculation Option1

Earthing Calculation Option1

Uploaded by

jm.mankavil6230
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
100% found this document useful (1 vote)
441 views6 pages

Earthing Calculation Option1

Earthing Calculation Option1

Uploaded by

jm.mankavil6230
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 6
> | Rev. | ate | Description Designed oe Client — — oe Bo rl ig ot ss Dt | Abu Dhabi Water & Electricity Authority [Consultant via SwedPower International AB -WWORLD WIDE CONSULTANT- ‘Contractor ~ LARSEN & TOUBRO LIMITED ECC DIVISION Project ~ — EXPANSION & REINFORCEMENT OF 33KV NETWORK IN AL AIN AREA OF ABUDHABI - U.A.E FOUR NEW 33/11KV PRIMARY SUBSTATION IN AL AIN AREA CONTRACT NO. G1409 [Document Title Earthing Design Calculations ~ DAHIR S/S [CSD Number SCALE | NTS Git j4}to}s}|-|-|R/t}]_7)/8 {3 |o| sv] 3]s5]o |] Al DATE | 17.404] NO. OF | SKA _ AKSM. KRJ SHEET | SIZE DESIGNED CHECKED |__ APPRoveo we | Aa PRELIMINARY | ~ TENDER INFORMATION ‘APPROVAL | CONSTRUCTION LARSEN & TOUBRO LIMITED ECC Division - EDRC (Electrical) S for ATAin REF NO; [GI409-RLTSSOISS0A [PAGE 02 OF 06] PREPARED | CHECKED [APPROVED] DATE ‘SKA KS. KR 17-04-2008 [PROJECTS S3/T1KV'S [TITLE: EARTHING DESIGN CALCULATION FOR SIS CONDUCTOR SIZING - DAHIR TS GENERALLY BASED ON IEEE 80 - 2000 :CTION S$ =1xSQRTW)/k S= AREA OF CONDUCTOR IN Sq.mm I= EARTH FAULT CURRENT IN AMPS {= EARTH FAULT CLEARING TIME IN sees. k SQRT(( Qe x (B420)/delta20) x ln (1+ (QLQIMB+Q)) Qe = Volumctric Heat capacity of conductor (J/"C mm3 ) B = Reciprocal of Temp.Coeff. of Resistivity (°C) delta Electrical Resistivity of conductor at 20°C ( Ohm. ) Qi= Initial Temperature of Conductor (C ) Qf= Final Temperature of Conductor (°C) 31500. amps L V see Qe= 0.00345 J/°C mms 1 Data for copper conductor B= 24s °C 0000020 Ohm.mm Gs 40°C 700 °C SQRT( (0.00345x (234.5 + 20) 0.00002) x In (1+ ((700-80 ) / (235 +40) )) 231,909 31500 x SQRT (1.0) / 231.909 135.83 Sq.mm [Corrosion allowance considered for the conductor in percentage = los [Minimum area of cross-section required = 149.41 Sq.mm_ Hence conductor size selected is, 300 Sq.mm (Which isthe minimum size specified in the specification) CONDUCTOR $1 JOSENIS, $06 Copper Flat LARSEN & TOUBRO LIMITED ECC Division - EDRC (Electrical) |Conductor Size Equivalent diameter = [Length of Switchyard Breadth of Switchyard No: oF grids in X direction 5 No: of gris in ¥ direction = Equivalent Number of grids n Spacing of conductors D : [Total length of conductors Le a |Area of Gri As Depth ofburial - Depth of Top Layer hs = Total No of electrodes _m : Length of electrode 1 Total length of electrodes Lr = Diameter of electrodes. di 5 Duration of Fault Current ts = [PROJECT: 33/11KV S/S for AI Ain REFNO: _[G1409-RL78301350A [PAGE 03 OF 06 PREPARED | CHECKED | APPROVED, DAT [TITLE: EARTHING DESIGN CALCULATION FOR SKA, KS) KR 17-04-2004 SiS-DAHIR ICALCULATIONS ARE BASED ON IEEE 80 - 2000. DESIGN DATA System Voltage e 33 kV [system Grounding = soLID Soil Resistivity p 5 9.32 Ohman Top Layer resistivity ps = 2000 Obmm (Actual value of resistivity of erushed rock shall be used after measurements) |Max. Earth Fault Current (1) = 23625 AMPS (Current division factor 0.75 as per specification) 50x 6 Copper Flat 0.0195 m. 37 m (Grid extended by 0.5m on both sides) 46m (Grid extended by 0.5m on both sides) 8 ie. SQRT(O * 8) 870 m 2622. sqm os (As per specification) 0.08 m Nos 45 m 20 (As per specification) LARSEN & TOUBRO LIMITED ECC Division - EDRC (Electrical) [PROJECT: 33/1 KV SIS for Al Ain REFNO: [G1409--RI78301350A [PAGE 04 OF 06 PREPARED | CHECKED | APPROVED DATE TITLE: EARTHING DESIGN CALCULATION FOR SKA AKS KR 17-04-2004 /S - DAHIR Etouch = cs cs Etouch = Estep = Estep Emesh = Km = Ki = Kh = ho Kh Km = Estep = Estep [Tolerable Touch Potential (1000 + 1.5 * Cs * ps) *0.116/SQRT%s) 1 a* {(1- pips) /(2* hs +a) } 0.106 m 1 -0,106*(( 1 - 9/2000 )/( 2 * 0.08 + 0.106) } 0.6034 (1000 + 1.5 * 0.6034 * 2000) * 0.116 / SQRT( 1.0) 325.97 Volts Tolerable Step Potential ( 1000 +6.0 *Cs * ps } * 0.116 /SQRT(s) (1000 + 6.0 * 0.6034 * 2000 ) * 0.116 / SQRT( 1.0) 955.88 Volts | Mesh Potential Attainable (Cpt Km* Kit 1)/ (Le + 115 *Lr ) (BASED ON TEEE 80 - 2000 CHAPTER &) For body weight of 50 kg E80 - 1986 Refer page 41 IE (BASED ON IEEE 80 - 2000 CHAPTER 8) For body weight of 50 kg (BASED ON IEEE 80 - 2000 CHAPTER 16) 1(2* n)* (Inf D216 * h d+ (D+.2h) A2/(8*D* ad) -hI4* Ad] + Kii/ Kh Inf8/(e* (2 * -1))] 1.00 for grids with ground rods in perimeter SQRT (1+ hvho) 1.00 m (reference depth of grid) SQRT(1+0.500/10) = 1.2247 1/2 * 22/7) * { In[7.0°21 (16 * 0.500 * 0.02) + (7.0 + 2.# 0.500 )42/( 8 * 7.0 * 0.02) - 0.500/ (4* 0.02) | + 1.00/ 1.2247 In[ 8/ (22/7 (2* 8.00-1))]}} 0.7085 0.64440.148" n= = 1.8280 0.644 +0.148 +8 = 30936 Volts 1p Potential Attainable CpeKs® Ki © 1)/( Le + 1.15xLe ) 1/m* {1/2 *h) + 1/D+H)41/D*C- Emesh = (9 * 0.7085 * 1.8280 * 23625 )/( 870.0 + 1.15 * 45) (BASED ON IEEE 80 - 2000 CHAPTER 16) 05%0-2)) } 9 (Higher of the no.of grids in X & ¥ direction) (1/2277) * (1/2 *0.500) +1/(7.0 +0500) +1/7.0* (1-0.549-2)} 0.4057 (90.4057 * 1.8280 * 23625 177.17 Volts 1( 870.04 1.15 45) LARSEN & TOUBRO LIMITED ECC Division - EDRC (Electrical) PROJECT: 33/11KV S/S for Al Ain REFNO: [G1409-RL78301350A [PAGE 05 OF 06 PREPARED | CHECKED | APPROVED DATE [TITLE: — EARTHING DESIGN CALCULATION FOR SKA AKS KR 17-04-2004 SIS- DAHIR Comparison of Tol {Tolerable Etouch = 32597 Vols. Lroterable Estep = 95588 Vols Atainable Emesh = 309.36. Volts Atainable Estep = 177.17 Vous \Since Attainable Emesh is less than Tolerable Etouch and Attainable Estep is less than Tolerable Estep, the design is safe. LARSEN & TOUBRO LIMITED Ecc ion - EDRC (Electrical) PROJECT: 33/1 1KV S/S for Al Ain REFNO: [G1409-RL78301350A [PAGE 06 OF 06 PREPARED | CHECKED | APPROVED DATE TITLE: EARTHING DESIGN CALCULATION FOR SKA ‘AKS: KR 17-04-2004 SIS - DAHIR [CACULATION OF GROUNDING RE |BASED ON IEEE 80-2000 CHAPTER 14 ROUND RODS Re = p/(@*m* x1)? [In(@*1/d)- 142% KI * 1/SQRT(A)* (SQRT(m)-1)%2 } Kl = 136 Refer Fig 25A page 67 IEEE 80 - 2000 Re = 9/(2* 15 #22773) *[ In(B*3/ 20/ 1000))-1+2* 1.36% (3 / sqrt(2622)) * (sqrt (15)-1)*2 } 03819 Ohms RI p/(x*Le)*[In(2 *Le/h’) + KI *( Le/SQRT(A)) - K2] KI = 1236 S37 Refer Fig 25B page 67 IEEE 80 - 2000 SQRT(d * h) - SQRT(0.02 * 0.50) = 0.0988 Rs = (9/ (22/7 * 870.00) * [ In (2 * 870.00 / 0.0988 ) + 1.36 * (870,00 / sqrt (2622.00 ))-5.7] = 00927 ohms : BETWEEN GROUND GRID AND GROUND RODS Rse pA * Le) * [In (2 * Le/1) + Kt * (Le / SQRT(A)) - K2 + 1] Kl = 136 k= 57 Rse = 91 (22/7 * 870.00) * [In (2 * 870.00 / 3) + 1.36 * (870.00 / sqrt (2622.00 )) - 5.74 1) 0.08450 Ohms | COMBINED RESISTANCE OF GROUND GRID AND GROUND RO! Rg (Re * Rs - Rse*2)/ (Re +Rs- 2 * Rse) Re (0.3819 * 0.0927 - 0.08452 )/( (0.3819 * 0.0927 - 2* 0.0845 ) 0.0925 Ohms [Hence the design adopted meets the specification requirement with respect to i) STEP & TOUCH POTENTIAL COMBINED RESISTANCE OF GRID & GROUND RODS < 1.0 OHM |NOTE ‘The conductors shall be uniformly distributed in area of 57m x 46m leaving the space for building area of 38m x 27m. ie, Earth mat (Conductor length of 870m as per above calculation) shall be laid in s/s around the building with reduced juniform spacing.

You might also like