Webinar Q&A
This document summarizes the responses to questions posed before and during the webinar on general
Heat Exchanger Design topics. The topics have been arranged into four different categories:
1.
2.
3.
4.
5. How do you anticipate and compensate for fouling pressure drop increases?
If the user specifies a fouling layer thickness explicitly under Input > Program Options > Fouling the
program will calculate the impact of this on hot-side and cold-side pressure drops. On the shellside,
the fouling will be assumed to also block the tube-to-baffle clearance and the shell-to-baffle
clearance. If you specify a process fouling, resistance, and thermal conductivity of the fouling
material, the layer thickness can also be calculated.
6. Is the complex design, Triple Segmental, supported by TEMA?
TEMA recognizes single-segmental, double-segmental, and triple-segmental baffle arrangements. If
you have a large shell diameter and a large number of tubes, this can give a practical design that has
a feasible baffle overlap (usually 2 or more tube rows overlap). Several of our fabricators who have
been using our arrangement of triple-segmental baffles for years have had good results.
Design Mode: Performs an extensive design search to find the best exchanger geometry to
achieve the specified duty. Requires a set duty and allowable pressure drops.
Rating/Checking Mode: The geometry and process conditions are specified by the user.
The program compares the area required to perform the duty with that specified in the input.
The main results are the area ratio (>1 the exchanger is over-surface, <1 the exchanger is
over surface). Some engineers use repeated rating calculations to manually find their choice
of design. If the area ratio is far removed from 1.0 then Simulation will provide more reliable
results.
Simulation: Considers the exchanger geometry to be fully specified and calculates the outlet
stream conditions that can be achieved in the exchanger from the specified inlet conditions.
Find Fouling: This calculation mode is similar to rating but adjusts the fouling resistance to
determine the maximum values which gives an area ratio of 1.
12. How do you generate plots of S&T heat exchanger performance in EDR? Can you generate an
overall schematic of several exchangers in series or parallel?
In the new Shell & Tube ConsoleV8 onwardstemperature profile plots for shellside and tubeside
are shown after each run.
You can also view detailed output from the Aspen Shell & Tube incremental calculations under
Results > Calculation Details > Analysis along the shell/ Analysis along the tubes. There is a
tab available where you can view plats of temperature, pressure, heat transfer coefficients, vapor
fraction etc. Currently there is no schematic of shells in series and parallel.
13. If I have a two-phase case (two-phase on both sides), how can I check the Heat of
Vaporization in the simulation? Can the EDR plot this?
Under the Overall summary, you will find a tabulation of the breakdown of heat load for a two-phase
case (Figure 2):
results of EDR sizing can help to achieve a more accurate dynamic model in Aspen Plus and Aspen
HYSYS .
15. Does the exchanger rating also take into account seasonal variations in temperature of the
environment, as well as climatic variations of different countries?
Within EDR, you can set up thermal models in Rating or Simulation modes for different operating
conditions and track the results under Results > Results Summary > Recap of Designs. You may
also find it very useful to use Aspen Simulation Workbook with EDR to conduct case studies of this
naturewith EDR working within Microsoft Excel. Visit the Support site and view Knowledge Base
Item number 130667: Exploring multiple operating scenarios using Aspen Simulation Workbook and
Aspen Shell & Tube Exchanger.
With your EDR models embedded in an Aspen HYSYS or Aspen Plus simulation, you have a much
more effective tool to study how an exchanger and the overall process will react to seasonal
variations.
16. Can the bend of the U-bundle be supported?
Yes, you can specify a full baffle support and additional supports around the U-bend region itself.
These can be very important in combatting flow induced vibration.
17. Does EDR have the ability to model condensers using differential heat curves?
With the old B-JAC properties and VLE methods, you can specify differential condensation curves.
It is normal to use the integral condensation method which has been proven to be accurate for a
wide range of process conditions. Stream data transferred from the simulators is provided in integral
VLE curves.
18. Is there a separate package to the HTRI program that is already supplied by AspenTech?
AspenTech does not supply HTRI software products; HTRI is a competitor.
19. What are the major differences between EDR and HTRI? How does the thermal design
compare with HTRI models?
AspenTech is unable to make direct comparisons of our offering to HTRIs; however, there are many
benefits to using Aspen EDR. The webinar associated with this Q&A document focuses on several
of these benefits, including:
Integration with Simulation: Aspen EDR models can be embedded in flowsheets from
Aspen Plus & Aspen HYSYSindustry leading process simulators for both Chemicals,
Oil, and Gas applicationsimproving flowsheets for revamp studies, troubleshooting
operations, and debottlenecking processes. See the Petrofac Case Study for an example
of how a customer benefitted from rigorous Aspen EDR models in Aspen HYSYS.
Physical Properties: Aspen EDR can import properties from Aspen Plus & Aspen
HYSYS cases (as shown in the webinar) or properties can be specified using one of the
included databanks: BJAC, Aspen Properties, or COMThermo. The integration and the
breadth of the property databanks significantly reduce the time required to input process
data.
Thermal Modeling: EDR thermal modeling is based on our HTFS research heritage from
the late 1960s and continues with our current programs. This provides state of the art
correlations and methods documented in the Aspen HTFS Research Network. The
Research Network is licensed by many of our leading customers. We are regularly
involved in analyzing comparisons between our results and those of other software
suppliers. When called upon, we are always happy to demonstrate the validity of our
methods with reference to sound theory and extensive validation data covering a wide
range of exchanger configurations and process conditions.
Thermal Design Optimization: Aspen Shell & Tube typically evaluates hundreds of
exchanger configurationsconsidering the number of shells required, as well as details
of shell geometry. The optimum design is selected on a rigorous algorithm for cost of
labor and materials of construction. Similar optimization capabilities are also available in
the Aspen Air Cooled Exchanger program.
Mechanical Design Optimization: Aspen Shell & Tube Mechanical is the only pressure
vessel design product on the market that was developed exclusively for heat exchangers.
Drawing on the long heritage of the B-JAC Teams program, Aspen Shell & Tube
Mechanical provides powerful, optimized mechanical design that recognizes the
interaction of key components. The designs produced minimize material thicknesses and
reduce costs while still maintaining design integrity and conforming to internationally
accepted code standards.
Thermal & Mechanical Integration: The integration between the thermal software and
the mechanical software significantly reduces the time to hand off designs between
thermal designers and mechanical engineers.
If youre interested in learning more about how Aspen EDR can benefit your business, please
contact your Sales Account Manager or visit www.aspentech.com/products/aspen-edr.aspx.
Input/UI
1. When rating an existing exchanger, how do you change the way baffle cut is specified
(% area vs. % diameter)?
In the EDR Shell & Tube program, the baffle cut is expressed as a percentage of the shell inside the
diameter. You will need to use a manual calculation from the figures expressed in the percent shell
side net free area (taking account of the area occupied by the tubes) to convert to a % shell diameter
basis.
2. Where does EDR put in supports (I'm talking about the extra supports option)?
If you specify additional supports between tubes in window baffles, these are equally spaced between
baffles. They will appear illustrated on the setting plan. Similarly, additional supports in inlet and
outlet regions will be equally spaced between the first baffle and the tube sheet.
3. How do you export heat exchanger process conditions from Aspen Plus to EDR?
On a HYSYS Exchanger, go to Design > Parameters and select Rigorous Shell & Tube as your
Exchanger Model. Then, go to the Rigorous Shell & Tube tab and click the Export button, which will
then open a file. Save the file, choose a folder location, and name it as .EDR.
4. How can you have two outlet streams (flashed vapor and liquid) on one side of a Heat
Exchanger?
In Shell & Tube under Input > Exchanger Geometry > Nozzles you can select the option to have a
separate liquid and vapor nozzle. You may also specify dimensions or have the program size these
for you.
5. How can I send the calculated geometry back to Aspen HYSYS and/or Aspen Plus to be used
in the simulation?
When you have an EDR model, you can import it into a HYSYS Exchanger. Go to Design >
Parameters and select Rigorous Shell & Tube as your Exchanger Model. Then, go to the Rigorous
Shell & Tube tab and click the Import button. A file will appear. Open the dialogue box which allows
you to browse a folder location where you select your case file .EDR.
6. Where can I find the internal volume of a heat exchanger, Shell and Tube side, to calculate the
necessary mass of the fluid?
The Shell and Tube Mechanical program outputs the shell side or tube side volumes, as well as the
Operating Weight (with the process fluids present). See Figure 3 below.
7. Where is the actual area vs. the required area reported on when rating an existing exchanger?
You can find the area ratio on the Results Summary > Overall Summary form, and on the Thermal
Hydraulic Summary > Performance form (Figure 4).
Calculation Results
1. Can you obtain a results report with the thermal and mechanical design combined?
Currently, our Shell & Tube Thermal and Mechanical programs produce individual reports which you
may tailor to your needs.
2. How would you design and double pipe an exchanger?
Under Input > Exchanger Geometry > Shells/Heads/Flanges > Shells/Heads you can select the
shell type as Double Pipe (designated as D-type).
3. Before we begin, does it apply to both Division 1 & 2 of the ASME code?
The mechanical calculations apply to ASME Division 1. ASME is progressively bringing together
mechanical calculations so that more advanced Division 2 methods can be added to our program with
each release.
4. In X shell design, what is the accuracy level in the mechanical design when shell side nozzles
are more than 2?
Generally, there shouldnt be problems with the mechanical aspects of multi-nozzle X-shell designs
unless the nozzles are in very close proximity. Please contact AspenTech Support if you have a case
you would like us to look at.
5. Do multi-nozzle X-shell designs consider heat loss, based on the environment, to insulation
thickness?
No, it is assumed that exchangers are well insulated.
6. How does Aspen EDR calculate the mixed oil and water viscosities?
In our research program, we have recently looked closely at modeling in this area and provided new
recommendations on handling the modeling of streams with two liquid phases. If you provide
property data for two liquid phases, the program will default to the new HTFS Method handling
condensation somewhat differently from heating or cooling with no phase change. You may also
over-ride the program selection under Input > Program Options > Methods/Correlations > General
and select your preferred method for viscosity of two liquid phases. You can also look on our support
site at the Aspen Support Knowledge Base Solution 133770 White Paper - Heat Exchanger Methods
for Effective Viscosities of Two Immiscible Liquid Phases.
7. EDR does not consider high pressure when calculating baffle thickness and number of
baffles. Why cant you fit the same number as calculated in EDR design?
Generally, there shouldnt be an issue with high pressure units in terms of number of baffles. What
might be more important here is the thickness of the tube sheets, positioning of nozzles, and the
interaction of these with the baffle spacing. Please contact AspenTech Support if you have a case
you would like us to look at.