Final CSR
Final CSR
Common Schedule of Rates (CSR) being published by Punjab, PWD from time to time is a very
comprehansive document and useful in execution of development works in Punjab. Apart from Punjab
PWD this CSR is being used by number of Boards, Corporations, Public Sector Undertakings, Private
Sector Builders and Architects etc.
The CSR was first published in the year 1962 followed by revision in the year 1987. During the last 21
years, CSR has not been revised. 25 Nos. Addenda and Corrigenda on CSR-1987 has been issued from
time to time. The prices of Labour and Material have increased many fold and to update the rates, the
ceiling premium are being fixed from time to time by Zonal Commiettee of Superintending Engineers of
various departments.
It is utmost needed that a re-print of CSR-1987 may be published by incorporating the A&C slips
No.1 to 21 and 25 (A&C slip No.22 to 24 relate to Specifications) including amendments issued in A&C
slips. Although this volume of publication contiains items of CSR-1987 the nomenclature of some items
has been improved by making it more generic. Items which are either obsolete or are not in use has been
deleted. Chapter No.2, is not in use these days and has been deleted.
I wish to place on record the tecnical input and effective co-ordination on the part of various technical
committees and the efforts put in by staff of CSR cell to finalize the re-print of CSR-1987.
I am also thankful to all the Chief Enginers and Superintending Engineers who gave their valuable
advice and full co-operation in the finalization of CSR-1987 Reprint.
I am sure that this CSR will be quite helpful to all the concerned in construction industry and
development works.
This re-print has been issued with the approval of the Committee of Direction of Chief Engineers.
2 The revision work was undertaken by the schedule of Rates, cell specially created for the purpose
under the supervision of a Superintending Engineer, PWD B&R Branch, Patiala assisted by three
Executive Engineers one each from B&R, Irrigation and Public Health Branches.
The Schedule of Rates cell after completing the revision work of the Common Schedule of Rates
obtained the approval in various meetings of the Committee of the Direction of Chief Engineers,
constituted vide Secretary to Govt. of Punjab PWD B&R No.22 (90) B&R-II (3)85/2723 dated 28th
June, 1985.
The new Schedule has been compiled in one volume, thus combining all the four volumes of 1962 in
one concise form for the convenience of ready reference. Volume-II of the erstwhile Schedule for "Hill
Region" has become redundant as a result of reorganisation of the State during 1966. Special rates
giving due weightage for the "Sub Mountainous Region" in the state, have been incorporated in the
schedule. The Schedule now comprises the following chapters :-
(i) Chapter No. 1 to 27 and 32 to 34 Buildings and Road Works and Irrigation Works
such as Outlets, Lining and River and Canal
Protection works etc.
3 This Schedule of Rates is applicable to the works to be executed by the various Branches of the
state PWD.
4 The Common Schedule of rates, 1987 will be operative with effect from Ist January, 1987.
5 The rates given in this Schedule are for normal construction and maintenance works. For large scale
projects, specialized and emergent works like closure works, separate rates may be determined by,
the Chief Engineer of the Department concerned.
6 This Schedule will not be applicable to the agreements and work orders already in vogue and these
will continue to be operated on the basis of the previous Schedule till their completion.
7 The areas in the state have been sub-divided into the following two zones :-
PLAINS
All districts of Punjab including Chandigarh and Municipal areas/notified areas of towns of the Sub-
mountainous region and road land width of Ambala-Chandigarh-Hoshiarpur-Pathankot-Madhopur
road.
SUB-MOUNTANEOUS REGION
Sub-mountaneous area includes the North Eastern side of Ambala-Chandigarh road starting from
Dera Bassi Block boundary to Chandigarh-Ropar-Garhshanker-Hoshiarpur-Dasuya-Mukerian-
Pathankot-Madhopur road, then turning to right side of River Ravi including the entire area of Punjab
upto J&K Border.
The works at New Delhi and Delhi shall be carried out on the basis of C.P.W.D. Schedule of Rates
and specifications.
8 The schedule of Rates, 1987 is based on detailed analysis of rates for each item of work, which is
also being printed separately for office use only. The analysis of rates is a strictly confidential volume
and the departmental officers must take care as not to divulge the same to the contractors.
9 The rates given in this Schedule are based on the latest edition of the Punjab P.W.D. specifications
including subsequent Addenda and Corrigenda issued from time to time for all chapters except
chapter No.24 "Road work" for which the specifications of Road and Bridge work evolved by the
roads wings of the Ministry of Shipping & Transport Published by the Indian Roads Congress New
Delhi, are to be adopted. The rates in respects of "Electrical Installations" Chapter 31 are based on
revised specifications, 1985.
10 (a) The Executive Engineers are empowered to pass mechanical jobs like repairs to truck and
tubewells not included in the Schedule upto Rs.500/- for each items not exceeding Rs.5000/-
(Rs.Five thousand only) in a year by calling open quotations.
10 (b) The Superintending Engineers are empowered to pass Miscellaneous items pertaining to
mechanical works like repair of Trucks & Tubewells not included in the Schedule of Rates upto
Rs.5000/- for each item; not exceeding Rs.50,000/- (Rs. Fifty thousand only) in a year. It has no
concern with non schedule items.
11 For the execution of works in villages and other isolated works not on main roads and involving the
use of skilled labour and costing upto Rs.5.00 Lacs, extra premium of 10% may be allowed for
estimating purpose over and above the premium or abatement fixed for the area concerned. The
contractor is to be paid only on the basis of rates of premium and abatement tendered by him on the
basis Schedule of rates i.e. not taking into consideration the 10 per cent applicable weightage in
ceiling premium. For isolated work and works in villages, tenders for such works should be clearly
invited on this basis. As regards classification of a work under this category, each case should be
examined on merit.
12 Unless otherwise specified, the labour rates for various items of construction include handling of
materials within 100 metres. The through rates include all rehandling of materials the site of work and
no payment is due to the contractor on this account.
13 The through rates, given in the Schedule, include the carriage of materials as follows :-
(a) For such materials as timber, and electrical goods, etc., which have to be arranged by the
contractor, the entire carriage is included in the rate, irrespective of the lead. For such materials
as bricks, brick ballast, bajri, sand, stone and cinder, extra lead involved beyond 5 Km., is
payable as per carriage rates.
(b) For materials like cement, steel etc., which are issued from Govt. stores, the through rates
include :-
(i) For works within municipal limits or within two kilometre periphery of municipal limits of the town
and having Govt. stores, all carriage irrespective of the distance of site of work from Govt. stores
of that town.
(ii) For work in places other than mentioned in (i) above, the carriage within a radius of 5 kilometres
of the site of work and in case of extra lead beyond this limit, carriage is payable at rates
provided in the Schedule for the corresponding subsequent kilometres.
(c) For bricks the through rates include the carriage within a radius of 5km. of site of work, if the
source of bricks is within that limit. In case the source is beyond the radius of 5 km. of the site of
work, the through rates include carriage upto first 5 km. measured from source of bricks
irrespective of the fact whether this initial distance consists of katcha and pucca or partly katcha
and pucca. The lead beyond this initial distance of 5 km. will be payable at the rates provided in
the Schedule of Rates for the corresponding subsequent kilometres. For this purpose the
source of bricks shall be the nearest possible working kiln or dump from where the bricks can be
obtained and the resources shall be certified as such by the Sub Divisional Engineer inwriting
before releasing the payment.
14 The through rates include all octroi charges, toll tax, sales tax and other local taxes etc., paid by the
contractor in bringing the material to the site of work.
15 The through rates include the wastage and breakage of various materials during construction.
16 Unless otherwise specified, the labour rates include the cost of water, tools and plants, labour and
materials for scaffolding and cost of good earth for mud mortar and mud plaster wherever required.
17 In case of works below ground level like basement of buildings and public health works such as
sewers, disposal works etc., the rates upto a depth of 4 metres below gound level, shall be the same
as for work in superstructure upto first floor level. For depths greater than 4 metres, additional rates
for subsequent storeys shall be added. For works which are not deeper than 1.5 metres from ground
level, ordinary rates for works in foundation and plinth shall apply.
18 Where the description of any item is too long, the essential portion has been printed in antique (thick)
letters. Only such essential portion need be written in estimates,tenders contract and measurement
books, although it will be deemed to cover the entire item as described fully in the Schedule Of
Rates. Where the description is only in one type of letters, It should be repeated as a whole.
19 Wherever the column for "Rates" is neither headed by "Plains" nor by "Sub-mountainous Region" the
same may be considered to apply to both the regions.
20 Abbreviations of units, wherever occuring, in the Punjab, P.W.D. Schedule of Rates 1987, First
Edition, are as under :-
A. LENGTH
Millimetre .. mm
Centimetre .. cm
Decimetre .. dm
Metre .. m
Decametre .. dam
Hectometre .. hm
Kilometre .. km
B. AREA
Square millimetre .. sq mm
Square centimetre .. sq cm
Squaremetre .. sq m
area .. a
hectare .. ha
Square Kilometre .. sq km
C. VOLUME
Cubic millimetre .. cu mm
Cubic centimetre .. cc
Cubic metre .. cu m
D. CAPACITY
Milli litre .. ml
Litre .. l
Kilo litre .. kl
E. WEIGHT
Milligram .. mg
gram .. g
kilogram .. kg
quintal .. q
Tonne .. t
F. DENSITY
Kilogram per ..
G. DISCHARGE
Note :- The above abbreviations signify both singular as well as plural number.
MISCELLANEOUS
Ampere .. Amp.
Diametre .. dia.
All Aluminium Conductor .. A.A.C.
(ii) Loading, un-loading, stacking and carriage. .. Length, breadth and height of stack shall be
measured correct to a cm. suitable deduction
shall be made to account for voids in loose
stacking according to factor, mentioned in
relevant chapters of specifications or
Schedule.
(iv) Supply and filling cinder on roof including .. Length and breadth shall be measured correct
light ramming. to a cm and average depth to 5mm.
(v) Items of skirting and dados, including that .. Correct to 3 mm where the height of skirting
on risers and treads of stairs of plaster, does not exceed 30 cm and where the height
precast terrazzo tiles, Agra red stone and of of skirting exceeds 30 cm, it shall be
terrazzo, etc. measured correct to a cm.
(vi) Items of skirting and dados, including that .. Correct to 1 mm where the height of skirting
on risers and treads of stairs of white does not exceed 30 cm, and where the height
Makrana Marble, Chittor Black Marble and of skirting exceeds 30 cm it shall be
of Kotah Stone. measured correct to a cm.
(viii) Wood work wrought, planed and fixed for .. In cubic metres nearest to four places of
trusses, chowkats etc. decimal. Length of each piece shall be
measured nearest to a cm and X-sectional
dimensions shall be measured as specified in
Ch. 17 of the Schedule, correct to 5 mm.
(xii) Steel windows. .. The unit will be sqm correct to two places of
decimal. The height and width shall be
measured correct to 0.5 cm.
21 FOR ROUNDING OFF THE VALUES, THE FOLLOWING RULES SHOULD BE APPLIED.
(i) When the figure, next beyond the last figure or place, to be retained, is less than 5 the figure in
the last place retained, shall be left unchanged.
(ii) When the figure, next beyond the last figure or place, to be retained, is more than 5 or is 5,
followed by any figures, other than Zero; the figure in the last place retained, shall be increased
by 1.
22 If tenders for any item are higher than the premium sanctioned in the Schedule of rates, the
Superintending Engineers of Irrigation Branch should first fully satisfy themselves about their
justification. If they feel that the work is of emergent nature and it can not be done in sanctioned
premium, he should under intimation to the Chief Engineer, sanction the tenders for work upto Rs.
1.00 lac(Labour Cost only). The rate being not more than 15% above the basic rate & Zonal
sanctioned premium. If the labour cost of work is more than Rs. 1.00 lacs, the tenders should be
referred to the Chief Engineer for acceptance.
25 (a) The rates for all the chapters (except item No 18.9, 18.10, 18.11, 18.12, 18.19, 18.20, 18.23,
18.25, 18.28, 18.30 & 18.32) are based on cement & steel to be issued from the Govt. store with
3% storage charges, hence no contractor's profit have been provided on cost of cement &
steel.
(b) Where the cement and steel (except items No.18.9, 18.10, 18.11, 18.12, 18.19, 18.20, 18.23,
18.25, 18.28, 18.30 & 18.32) are arranged by the contractor at their own cost, 10% contractor
profit may be added for these items.
IRRIGATION BRANCH
Chief Engineer.
MEMBER SECRETARY
SPECIAL INVITEE
1 Erratta to the Common Schedule of Rate 1987 Printed on Page (a) to (i)
2 A&C Slip No. 1 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 152-280/SRC Dt. 12.02.87.
3 A&C Slip No. 2 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 397-430/SRC Dt. 27.03.87.
4 A&C Slip No. 3 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 466-505/SRC Dt. 27/28.04.87.
5 A&C Slip No. 4 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 769-887/SRC Dt. 24.06.87.
6 A&C Slip No. 5 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 940-1074/SRC Dt. 17/21.07.87.
7 A&C Slip No. 6 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 1143-1280/SRC Dt. 12.11.87.
8 A&C Slip No. 7 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 1341-1480/SRC Dt. 22.12.87.
9 A&C Slip No. 8 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 357-515/SRC Dt. 03/04.05.88.
10 A&C Slip No. 9 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 106-240/SRC Dt. 24.04.89.
11 A&C Slip No. 10 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 342-484/SRC Dt. 08/09.05.90.
12 A&C Slip No. 11 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 612-800/SRC Dt. 21.08.90.
13 A&C Slip No. 12 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 699-844/SRC Dt. 24/25.06.93.
14 A&C Slip No. 13 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 950-984/SRC Dt. 20.08.93.
Sr. No. Description
15 Amendment to A&C Slip No. 13 & 14 vide Chief Engineer, Punjab, PWD B&R
Branch, Patiala vide Memo No. 48-82/SRC Dt. 18.03.94
16 Amendment to A&C Slip No. 13 & 14 vide Chief Engineer, Punjab, PWD B&R
Branch, Patiala vide Memo No. 387-415/SRC Dt. 02.06.94
17 A&C Slip No. 14 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 222-250/SRC Dt. 19/21.04.94.
18 A&C Slip No. 15 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 605-714/SRC Dt. 12.08.94.
19 A&C Slip No. 16 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 722-869/SRC Dt. 15.09.94.
20 Amendment to A&C Slip No. 5 vide Chief Engineer, Punjab, PWD B&R Branch,
Patiala vide Memo No. 1742-1771/SRC Dt. 27.09.95.
21 Amendment to A&C Slip No. 13 vide Chief Engineer, Punjab, PWD B&R Branch,
Patiala vide Memo No. 1585-1741/SRC Dt. 28.09.95.
22 A&C Slip No. 17 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 450-605/SRC Dt. 13.12.96.
23 A&C Slip No. 18 & 19 issued vide Chief Engineer, Punjab, PWD B&R Branch,
Patiala vide Memo No. 71-228/SRC Dt. 20/24.02.98.
24 A&C Slip No. 20 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 951-1112/SRC Dt. 26.11.98.
25 Amendment to A&C Slip No. 13 vide Chief Engineer, Punjab, PWD B&R Branch,
Patiala vide Memo No. 57-82/SRC Dt. 01.04.99.
26 A&C Slip No. 21 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 2-153/SRC Dt. 24.09.2003.
27 A&C Slip No. 22 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 158-318/SRC Dt. 17.11.2003. (Relates to Punjab, PWD
Specifications)
28 A&C Slip No. 23 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 325-485/SRC Dt. 05.02.2004. (Relates to Punjab, PWD
Specifications)
29 A&C Slip No. 24 issued vide Chief Engineer, Punjab, PWD B&R Branch, Patiala
vide Memo No. 878-1037/SRC Dt. 24.01.2005. (Relates to Punjab, PWD
Specifications)
CHAPTER NO. 1
DAILY WAGES
(i) The wages given below have been adopted for analysing the rates of various items of works.
(ii) For employment of departmental labour on Muster Rolls, the rates given below may be considered
as maximum rates upto which an Executive Engineer can authorise employment of labour. If in a
certain locality, prevailing conditions, necessitate payment on higher rates of wages, the
Superintending Engineer shall increase the rates suitably upto maximum of 50% above these
rates. This increase in rates shall be for a specified period not exceeding 3 months after which the
rates shall be reviewed again and revised downwards if the conditions so warrant.
(iii) The Chief Engineer of a branch, shall have full powers to authorise any increase in the labour
wages for departmental work for any length of time in any particular locality.
(iv) These rates are exclusive of contractor's profit and overheads and are exclusive of the wages for
weekly day of rest.
(v) The labour rates taken in this chapter are as per prevailing market rates as on Ist January, 1985.
(vi) In the case of excavation of earth work departmentally by employing labour on Muster Rolls, the
out put by female mazdoor may be taken as 10% less than that by male mazdoor. The extra
expenditure on account of this may be charged to the work concerned.
Sr. No. Description Unit All inclusive
Wages
1 2 3 4
1.1 Air-Conditioner/Refrigerator Mechanic Per Day 38.50
1.12 Boat on hire (Capacity not less than 4 with boat man) Per Day 42.00
1.63 Mason for plaster of pairs work (Ist Class) Per Day 30.00
1.64 Mazdoor Boy (Not less than 14 years) Per Day 12.75
1.81 Painter and Paper Hanger (Ist Class) Per Day 26.75
1.82 Painter and Paper Hanger (2nd Class) Per Day 21.50
1.91 Stone Chisler with Cutter (Ist Class) Per Day 26.75
MONTHLY WAGES
MATERIALS
Notes :-
(i) All the rates in this chapter are for materials at the source except where specified otherwise.
(ii) In the rates given below, royality has been included as follows :-
(b) Bajri and other Materials Rs. 0.70 per cum. or part thereof,
(iii) The rates are for the purpose of analysing the rates and not for obtaining supplies from market which
shall be obtained after calling tenders or quotations. In case of bricks and tiles, the tendered rates
shall not be more than controlled rates fixed by the Deputy Commissioners of the respective districts.
(iv) The rates for items No. 3.14 include the cost of Land and Water. In cases where Land and Water is
given by Government free of cost, the rates shall be suitably reduced.
(v) The rates for portland cement-vide item No.3.18 is for analysis and not for the purpose of issuing
cement to contractors. The issue rate for cement shall be fixed by Executive Engineer after taking
into account any extra Lead involved from Railway Station.
(vi) Deleted
(vii) Two classes of paints have been provided viz. the ordinary quality paints and special quality paints.
The paints, which are available on the rate contract of the Controller of Stores, Punjab, come under
the category of ordinary quality. The special quality paints will be first quality paints manufactured by
reputed firms like Nerolac, Asian, Berger, J&N, ICI or equivalent, approved by the Engineer-in-
Charge. Normally, in this category, will be included special paints, which have been manufactured by
the firm of a long standing and repute, whose products have proved to be of special quality, by
actual use, on some works. Special quality paint shall be used only, when these are specially
provided in the technically sanctioned estimates.
(viii) The rates in this chapter are inclusive of all octroi charges, toll tax, sales tax & other local taxes.
(ix) Deleted
(x) Deleted
(xi) While making measurements for payment purposes, suitable deduction shall be made for voids to
accounts for loose stacking of aggregates/boulders as stipulated in the relevant specification.
Sr. No. Description of Item Unit Chandi- Pathankot Damtal All Zirakpur Bharatg
garh, Mamoon quarry Dadri quarry arh
Panchkula, quary quarry quarry
Devinagar,
Surajpur
quarry
1 2 3 4 5 6 7 8 9
3.1 Aggregates :-
Sr. No. Description of Item Unit Chandi- Pathankot Damtal All Zirakpur Bharatg
garh, Mamoon quarry Dadri quarry arh
Panchkula, quary quarry quarry
Devinagar,
Surajpur
quarry
1 2 3 4 5 6 7 8 9
(f) Crushed stone aggregate (For
bituminous Macadam) -
1 2 3 4
(i) Size 40 mm gauge. Cum 44.00 ---- ---- ---- ---- ----
(ii) Size 25 mm gauge. Cum 50.00 ---- ---- ---- ---- ----
(iii) Size 20 mm gauge. Cum 55.00 ---- ---- ---- ---- ----
(i) Size 40 mm gauge. Cum 40.00 ---- ---- ---- ---- ----
(ii) Size 25 mm gauge. Cum 45.00 ---- ---- ---- ---- ----
(iii) Size 20 mm gauge. Cum 50.00 ---- ---- ---- ---- ----
(h) Stones breaking into spalls, size 75 Cum 11.00 ---- ---- ---- ---- ----
mm.
(i) Stones breaking into ballast
(excluding screening and washing)-
(i) Size 40 mm gauge. Cum 23.00 ---- ---- ---- ---- ----
(ii) Size 25 mm gauge. Cum 27.00 ---- ---- ---- ---- ----
(iii) Size 20 mm gauge. Cum 37.00 ---- ---- ---- ---- ----
1 2 3 4
(xii) North light adjustable ridge 1.22m long. Pair 64.00
3.5 Ballies :-
(I) Deodar -
3.6 Bamboo :-
(i) Bitumen felt, Fibre base, self finished type-2 grade- Sqm 21.00
I.
(ii) Bitumen felt, Hession base, self finished type-3
grade-I. Sqm 22.00
3.10 Boards :-
3.11 Boulders
(f) Modular brick tiles 19cm x 9cm x 4cm actual for roofing,
flooring, tile masonary and canal lining at kiln site
(g) Brick bats for well burnt or burnt bricks. Cum 41.00
3.16 Cast iron rain water pipe & fitting at site of work :-
(i) C.I. Rain water pipe (Non pressure) 100mm dia. Metre 52.00
(ii) H.C.I. soil pipe 100mm dia ISI mark. Metre 62.00
3.17 Celotax sheeting at site of work (½ inch) 12mm thick. Sqm 87.00
3.18 Cement
(b) White cement including bag at P.W.D. Godown. Per bag of 50 Kg. 348.00
(b) Handles
(C) Commercial Ply on one face & Teak Surface on other surface
3.24 Galvanised, iron sheet (0.80mm) plain or corrugated at site of work. Tonne 12500.00
(a) Plain
(b) Frosted
3.31 Hession cloth at site of work 1 metre width & weighing 400 gms per
meter. Metre 6.00
3.36 Kankar including digging breaking & cleaning duly stacked at quarry
including royality. Cum 25.00
3.37 Lime
(b) Delivered at site of work for small requirements up to 4 Qtl. Qtl. 123.00
3.38 Linoleum plain coloured at site of work 3.20mm thick. Sqm 62.00
3.39 Lubricants
3.41 Marble piece for crazy floor 25mm to 32mm. Qtl. 160.00
3.44 (i) Muslin cloth for lining (1.5M wide). Metre 26.00
3.45 Cramp
3.46 Copper pins 6mm dia 7.5 cm. long. Each 2.00
3.47 Niwar
Distempers
(b) Oil
(c) Paints
(xiii) Ready mixed paint for wood work or wooden surface in all
shades. Litre 39.00 26.00
(xvii) Roofing white ready mixed paint for corrugated sheets. Litre 42.00 30.00
(xviii) Roofing red grey or green ready mixed paint for corrugated
sheets. Litre 39.00 26.00
(i) Black red chocolate colours and dark shades. Kgm 18.00 -
(ii) Red chocolate orange buff or yellow paint (Red oxide of iron)
Light shades. Kgm 17.00 -
(e) Primers
(f) Polish
(g) Varnish
(i) Acid resisting varnish. Litre 52.00 -
(i) Rolling shutter made of 80mm x 1.25mm machine rolled laths. Sqm 179.00
(iii) 27.5 cm. long wire spring, grade No.2 for rolling shutter. Each 71.00
3.50 Sand
(b) Clean and screened sand within 30 metres excluding washing but
including royality where removal of over-burden of Soil above 30 cm
depth is necessary. Cum 9.00
(c) Clean, sharp and coarse sand from the following quarries (including
royality etc.) :-
3.56 Steel
3.57 Miscellaneous
Surkhi
(a) Surkhi prepared from well burnt bricks, ground and Screened
at source. Cum 119.00
(a) Cheel
3.60 Wire Gauge 22 gauge 12x12 mesh of (140 G gauge) at site of work Sqm 30.00
.
3.61 Expanded metal 20mm x 60mm strands 3mm wide and 1.6mm thick. Sqm 36.00
3.64 Fire Bricks size 22.86cm x 11.11 cm x 6.83 cm. 1000 Nos. 10000.00
(i) Where the lead for loading and unloading is more than the lead specified in the following rates, this
should be paid at carriage rates (Chapter No. 5) for second and third chains of 30 metres length as
the case may be.
(ii) The following rates do not provide for any special arrangements such as provision of mechanical
equipment for loading purposes. The unloading of heavy machinery or consignments requiring crane
work or special arrangements, will be done departmentally or paid for on the merit of each case.
(iii) The rates for unloading metre gauge wagons will be 2/3rd the rates for broad gauge wagons where
the unit for measurements is specified as wagon.
(iv) While making measurements for loading, unloading or stacking suitable deductions shall be made to
account for voids in the loose stacking according to the factors mentioned in the relevent
specifications of materials as given in chapter No. 3 of the P.W.D specifications.
(v) The rates of loading, unloading and stacking shall also include the loading, unloading and stacking of
containers in which the materials are contained. For instance, if 100 tonnes of bitumen are loaded or
unloaded in 160/200 litres drums, the net weight of bitumen will be 100 tonnes and weight of the
drum will be over and above this weight. Nothing extra will be paid for the weight of the bitumen
drums which are supposed to be carried in addition to the bitumen with in the same rate.
(vi) The rates for unloading materials like sand, stone, ballast etc. from tipping wagons shall be reduced
by 50 per cent. There shall, however, be no reduction in rates for loading.
(vii) Bricks and tiles shall be properly stacked in vehicles and not dumped. While unloading these shall be
directly placed into stacks and not dumped on the ground and then stacked.
Sr. No. Description Unit Rate for
loading into
wagons,
Trucks or
boats within
15 metres
lead.
1 2 3 4
4.1 Stone (building or pitching) Sand, Fly Ash, Bajri, Shingle,
Spalls, Brick bats, Brick ballast and Stone metal. Cum. 3.00
4.3 Bricks 22.86 cm. size (including stacking) 1000 Nos 7.00
1 2 3 4
(i) 30.48 cm x 15.24 cm x 5.08 cm 1000 Nos 8.50
4.9 M.S. Bars, structural steel G.I. pipes and specials, C.I.
manhole covers, steps and other castings and other
ancillary items like lead, hemp-yarn etc. including stacking.
Tonne 10.00
4.10 (a) 200 Litres barrel full including stacking. Each 1.25
4.11 Small packages of store upto one quintal including stacking. Quintal 1.00
4.12 Timber sleepers (Standard sizes and by manual Labour) 100 Nos 20.00
(b) (i) Heavy above one tonne if crane or any other suitable
device is arranged by the Deptt. Tonne 8.00
1 2 3 4
4.15 Ballies :- Nos
4.16 Shutterings :-
4.18 Petrol 10 litre tins including checking and weighing. 100 Nos 7.00
1 2 3 4
4.24 H.D.P.E, pipes.
Tonne 10.00
Stacking within 15 metres of the unloading points into stacks of specified sizes.
4.26 Coal
Cum. 2.00
4.30 Tiles
4.34 M.S Bars, structural steel G.I. pipes and specials, C.I
Manhole covers, steps other castings and other ancillary
items like lead, hemp-yarn etc. Tonne 5.00
1 2 3 4
Note :- The rates of item No. 4.29 to 4.40 are not payable over and above the rates of item No. 4.3,
4.7, 4.9 to 4.11 and 4.20 to 4.24.
1.75
3.50
7.00
5
8.50
5.00
30.00
33.00
1.50
5.50
4.50
8.00
1.00
0.75
1.00
17.00
30.00
8.00
15.00
10.00
10.00
10.00
12.00
15.00
12.00
32.00
64.00
5.00
7.00
14.00
7.75
15.50
23.25
7.75
7.75
7.75
7.75
fied sizes.
(ii) For carriage of materials on river choe beds, 23 percent extra over the basic rates of kilometres
concerned, should be paid for actual river or choe bed-length involved.
(iii) For carriage of materials on unmetalled roads, 20 percent extra on the basic rates of kilometres
concerned excepting those for item No. 5.3 to 5.5 should be paid.
(iv) For carriage in sub mountainous area, the S.E. concerned may increase the carriage rates suitably
upto maximum of 30% of the rates provided for the plains, in case he is satisfied that the existing
schedule rates are not workable.
(v) Deleted
(vi) For carriage of lengths above 6 metres of heavy steel sections like R.S. Joists, rails etc. which cannot
be easily bent, increase the rates for steel in item No. 5.2 by 50 percent.
(vii) Deleted
(viii) Carriage work if done by boats shall be paid at the same rate as given in this chapter for carriage by
road.
(ix) Carriage rates of all materials carried in the containers include the carriage of containers in which the
materials are carried. Only the net weight of material carried, is payable excluding the weight of
container.
(x) The rates for carriage of materials manually upto 0.48 K.M. and by mechanical means for every K.M.
lead, have been given. In case actual lead exceeds one K.M. and falls into next, full rate of the next
K.M. will be paid i.e. fraction of the K.M. will be payable for the full K.M.
(xi) While making measurements of materials for the purposes of payment for carriage, suitable
deduction shall be made to account for voids in loose stacking. The factor will be different with
different materials and may be ascertained from the relevant specifications of that material, as given
in chapter No. 5 of PWD specifications.
(xii) The Superintending Engineer concerned may sanction the approved rates of Truck operators Unions
in specific and emergent cases, in case he feels that the existing schedule rates are not workable.
(ii) Cement
(iv) M.S Bars, steel, coal, lime G.I pipes and special C.I man hole
covers, steps and other castings and ancillary miscellaneous
items like lead, hemp yarn etc.
(v) Timber
2nd and 3rd chain, per chain of 30 metres. 1000 Nos 1.40
2nd and 3rd chain, per chain of 30 metres. 1000 Nos 2.25
2nd and 3rd chain, per chain of 30 metres. 1000 Nos 1.40
5.2 (i) Surkhi, Sand, Fly Ash, Bajri, Ballast, Stone Boulders, Kankar
and Building Rubbish.
(ii) Cement
(iv) M.S Bars, Steel, Coal, Lime, G.I pipes and specials, C.I
manhole covers, steps and other castings and ancillary
miscellaneous items like lead, hemp yarn etc.
(v) Timber
(ix)(a) Cast iron pipes 80MM i/d (Truck load 8.50 tonnes)
(b) Cast iron pipes 100mm to 150mm i/d (Truck load 7.0
tonnes)
0.50 K.M to 1.0 K.M Tonne 15.00
(c) Cast iron pipes 200mm to 350 mm i/d (Truck load 5.50
Tonnes)
(d) Cast iron pipes 400 mm to 600 mm i/d (Truck load 4.75
tonnes)
(xii)(a) S.W pipes 100 mm to 200mm i/d (Truck load 4.50 tonnes)
(b) S.W pipes 225mm to 450mm i/d (Truck load 4.00 tonnes)
(b) RCC pipes 200mm to 300mm i/d (Truck load 6.50 tonnes)
(c) RCC pipes 350mm to 450mm i/d (Truck load 6.00 tonnes)
(d) RCC pipes above 450 mm i/d (Truck load 5.0 tonnes)
(a) Mazdoor load upto 40 kg. and distance upto 3.0 K.M. Each 8.00
(b) Mazdoor load upto 40 kg. and distance from 3.0 K.M. to 6.0
K.M. Each 16.00
(c) Donkey load upto one quintal and distance upto 10.0 K.M
excluding Donkeyman. Each 8.00
(e) Camel load upto 2.50 quintals and distance upto 16 K.M.
excluding the wages of camel man. Each 20.50
(h) Add for every K.M for distance exceeding 8.0 K.M but upto
16.0 K.M in sub item (g) Each 4.00
5.5 Carriage over short distance of small consignments, upto 2.0 quintals
in weight including loading, un-loading and stacking.
(ii) Exceeding 150 metres and upto 300 metres. Piece 40.00
(ii) Add for every 300 metres but upto 1200 metres. Tonne 3.00
(iv) Add for every subsequent K.M upto 8.00 K.M Tonne 3.50
Note :- The rates under item No. 5.6 do not provide for special
carriage arrangements like cranes, trailors etc. Carriage of machinery
not covered by this item should be paid at special rates to be
determined after inviting quotations or tenders or the work may be got
done by employing departmental labour.
(vi) Above 3.0 K.M but upto 13.0 K.M 100 Nos 0.60
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
Per K.M
EARTH WORK
Notes :-
(i) Converting lift into horizontal lead :-- For converting lift into horizontal lead, the lift upto 3.6 metres will
be multiplied by 10 and from 3.61 metres to 6.0 metres, it will be squared and multiplied by 3.3 and
beyond 6.0 metres it will be multiplied by 20. No cross leads what-so-ever shall be measured and
paid for.
(ii) Rehandling of earth work and gravel work :-- The rates of rehandling of recently deposited earth work
and gravel work after excavation will be 20 percent less on excavation rates. Earth work deposited
before monsoon season which has had a full monsoon on it, will be considered as a normal earth
work for excavation.
(iii) Measurement of lift :-- The lift shall be measured from the centre of gravity of the excavated earth to
that of placed earth. This shall constitute the mean lift for that section. When earth has to be carried
over spoil bank and dumped beyond it, the mean lift would be the difference in levels between the
centre of gravity of the excavated earth and top of the spoil bank omitting the dowel.
(iv) Rates for additional lead have been given in slabs for 7.50 metres each of additional lead. If the lead
exceeds a slab by 1.50 metres or so, full payment for 7.50 metres lead will be made.
(v) The payment for compensation should only be made on the production of a certificate from the
revenue authorities that the contractor has paid compensation to the land owners. The compensation
of earth is not an allowance, and as such it is also payable, even if the earth is brought from a
distance more than 450 metres from private land, subject to production of a certificate, as referred to
above. However, no compensation is payable, when the earth is borrowed from Govt. Land.
Rate
1 2 3 4
6.1 Earth work of silt clearance of channels and drains :--
(c) Dressing for sub item (a) and (b) supra. 100 cum 36.00
(d) Extra for every 7.50 metres additional lead. 100 cum 13.50
Rate
1 2 3 4
(ii) Extra for every 7.50 metres additional lead beyond 300
metres but upto 450 metres. 100 cum 11.00
(i) Extra for wet earth work from bottom of excavation upto
level of sub soil water. 100 cum 223.00
(ii) Extra for wet earth work from level of sub soil water upto
30 cm above. 100 cum 114.00
(iii) Extra for wet earth work for depth above 30 cm of sub
soil water level. 100 cum 57.00
Notes :-
(i) Wetness allowance shall be payable only after obtaining
the written approval of the Superintending Engineer.
(e) Hardness
(i) Extra for hard soil with D.B.D. (Dry Bulk Density) from
1.6 to 1.7 gm/c.c. 100 cum 69.00
(ii) Extra for hard soil with D.B.D. (Dry Bulk Density)
exceeding 1.7 but upto 1.8 gm/c.c. 100 cum 137.00
Notes :-
Rate
1 2 3 4
(ii) For D.B.D. above 1.8 special reference shall be made to
the Superintending Engineer for decision who may allow
maximum extra rate upto Rs. 250-00 per 100 cum.
Note :- Deleted
(i) Extra for admixture of shingle or kankar upto 10 percent. 100 cum --
Note :- Slush is that which will not support a man’s weight. The
rate will be paid depending upon the nature of slush after
obtaining approval of the Superintending Engineer.
Note :- Dal dal is clay that will flow like molasses. The rate shall
be paid according to the merits of each case after
obtaining sanction of the Superintending Engineer.
Rate
1 2 3 4
6.3 Dressing of earth work :--
6.4 Compensation for earth taken from private land. 100 cum 23.00
(d) Extra for every 7.5 metres additional lead. 100 cum 21.00
(e) Extra for wet earth work above sub soil water level. 100 cum 172.00
(f) Extra for earth work under standing water. 100 cum 446.00
(g) Extra for earth work under flowing water. 100 cum 686.00
(a) For ordinary gravel soil involving pick work. 100 cum 989.00
Rate
1 2 3 4
(b) For semi conglomerate or soil of nature of pick jumper. 100 cum 1502.00
(d) Extra for wet work above sub soil water level. 100 cum 172.00
(e) Extra for earth work under standing water. 100 cum 446.00
(f) Extra for earth work under flowing water. 100 cum 686.00
(g) Extra for every 7.5 metre additional lead. 100 cum 21.00
(a)(i) Earth filling under floors with surplus ordinary soil or soil
containing gravel or kankar upto 40% excavated from
foundation and taken only from outside the building
plinth in 15 cm layers including ramming, watering and
consolidating lead upto 30 metres. 100 cum 252.00
(ii) Earth filling under floors with surplus soil containing more
than 40% gravel or kankar excavated from foundation
and taken only from outside the building plinth in 15 cm
layers including ramming, watering and consolidating
lead upto 30 metres. 100 cum 450.00
(c) Extra for additional lead above 30 metres. 100 cum As per rate
under item
No. 6.2 (c)
Rate
1 2 3 4
(i) Out side road boundary into depressions with combined 100 cum
lead of 15 metres inclusive of cost of explosive,
compressed air and T&P. Rate of item
No. 7.1 to 7.10
to be paid
according to
type of work
after Reducing
the rate by
10%
(ii) Extra for additional 7.5 metres lead above 15 metres. 100 cum 21.00
(a) Earth work over roofs of one storey building with good
earth free of any admixture of foreign matter including
breaking of clods, ramming, watering, dressing and
horizontal lead upto 30 metres. 100 cum 892.00
(b) Extra for additional lead above 30 metres. 100 cum As per rate
under item
No. 6.2 (c)
(a) Digging and loading in boats within 15 metres lead. 100 cum 412.00
(c) Extra for distance beyond 300 metres but upto 750
metres (per 30 metres). 100 cum 17.00
Note :- For lead beyond 750 metres the rates under item No. 6.2
(c) will be applicable.
(b) Hand shunting of N.G. tip wagons per 30 metres. 100 cum 21.00
(c) Unloading earth from tip wagon and clearing within 3.0
metres from rail. 100 cum 110.00
Rate
1 2 3 4
6.14 Making new boundary road including levelling and dressing 3.0
metres to 5.0 metres wide :-
Note :- The rates for item No. 6.13 are to be paid only in reaches
where no earth work for boundary roads is paid for.
Rate
1 2 3 4
(b) Double kassi stroke ‘V’ shaped minimum 10 cm depth. K.M. 60.00
(c) Double kassi stroke ‘V’ shaped minimum 15 cm depth. K.M. 80.00
Sub-
Mountainous
Region
Rate
5
292.00
412.00
36.00
13.50
292.00
Rate
5
600.00
16.50
11.00
223.00
114.00
57.00
69.00
137.00
Rate
5
343.00
53.00
48.50
452.00
--
86.00
137.00
223.00
140.00
to
340.00
340.00
to
452.00
Rate
5
38.50
54.00
27.00
23.00
624.00
730.00
798.00
21.00
172.00
446.00
686.00
54.00
686.00
989.00
Rate
5
1502.00
1965.00
172.00
446.00
686.00
21.00
252.00
450.00
561.00
776.00
As per rate
under item
No. 6.2 (c)
Rate
5
Rate of item
No. 7.1 to 7.10
to be paid
according to
type of work
after Reducing
the rate by 10%
21.00
892.00
As per rate
under item
No. 6.2 (c)
55.00
412.00
212.00
17.00
223.00
412.00
21.00
110.00
223.00
305.00
Rate
5
378.00
23.00
20.00
48.50
101.00
53.00
104.00
51.00
46.50
43.00
39.00
34.00
29.00
24.50
248.00
Rate
5
157.00
230.00
350.00
30.50
60.00
80.00
ROCK CUTTING
Notes :-
For converting lift into horizontal lead the lift upto 3.6 metres will be multiplied by 10 and from
3.61 metres to 6.0 metres, it will be squared and multiplied by 3.3 and beyond 6.0 metres, it will be
multiplied by 20. No cross lead what-so-ever shall be measured and paid for.
The lift shall be measured from the centre of gravity of the excavated rock to that of placed
rock. This shall constitute the mean lift for that section. When rock has to be carried over a spoil
bank and dumped beyond it, the mean lift would be the difference in levels between the centre of
gravity of the excavated rock and top of the spoil bank omitting the dowel.
1 2 3 4
Excavation including handling of materials within 15 metres inclusive
of cost of explosives, dressing, compressed air and T & P.
7.10 Extra for every 7.5 metres additional lead. 100 Cum. 21.00
DEMOLITION
Notes:-
The rates given under this chapter are subject to the following conditions in addition to the
conditions laid down in the public works "General Conditions of Contract etc." and PWD
specifications.
(i) Unless otherwise stated, the rates include sorting and stacking dismantled material and removing
the same within a distance of 100 metres.
(ii) The rates given below are for non-hydraulic works. For hydraulic works, which are required to be
dismantled these shall be enhanced by 50 per cent. (hydraulic works are those which remain
submerged under water for most of their lives). The items, which can be considered as hydraulic
works, are :-
"Stone masonry in lime or cement, burnt bricks, tile lining and tile masonry in lime or cement mortar,
lime or cement concrete and reinforced cement concrete, and pucca grouted pitching when under
water."
(iii) Unless otherwise specified, the rates cover the cost of all tools and plants, ladders, scaffolding and
all other adjuncts required for dismantling.
(iv) Dismantling should be done with care and with little or no damage to the materials released.
Sr. No. Description Unit Rates in
Plains & Sub-
Montainous
Region
1 2 3 4
8.1 Dismantling stone masonry/Rubble masonry including stacking of
serviceable materials and disposal of unserviceable materials.
(b) Stone pitching laid dry but grouted with natural silt and clay Cum. 13.00
(c) Stone pitching laid dry but grouted with dry ballast. Cum. 9.90
(d) Stone pitching grouted with dry ballast and with natural silt and
clay. Cum. 14.00
1 2 3 4
(c) In wire crates including opening of crates and stacking crate
material. Cum. 11.50
Note :- When the work to be dismantled under items No. 8.2 and 8.3 is under
water, add 60 per cent to above rates.
(c) Mud roofing with wooden planks laid over battens. Sqm. 2.15
1 2 3 4
8.11 Stripping and stacking iron sheets of a roof including ridging, flashing,
eaves boards gutters and down pipes. Sqm. 1.35
8.12 Add for planks and battens in cases of item nos. 8.10 and 8.11 . Sqm. 1.15
8.13 Add for roof trusses of iron or wood, (rafters, purling etc.) in case of item
Nos. 8.10 and 8.11. Sqm. 2.30
8.18 Dismantling brick or flagged stone flooring including concrete base. Sqm. 3.50
8.19 Dismantling brick or flagged stone flooring without concrete base. Sqm. 1.20
8.26 Removing Doors and Windows (Steel or wood) with chowkhats by making
recesses in walls when the wall is not to be dismantled.
1 2 3 4
(b) above 300 mm to 600 mm dia Metre 6.40
8.28 Removing sal ballies from structures including stacking. Each 1.60
8.29 Dismantling sleepers from centring including stacking outside. Each 1.60
8.31 Scraping
(a) White wash and colour wash Sqm. 0.29
(e) Bricks dismantled from brick work in lime or concrete 1000 Nos 65.00
(f) Bricks dismantled from brick work in mud. 1000 Nos 16.00
(g) Tiles dismantled from the work in lime or cement. 1000 Nos 85.00
8.32 Dismantling wire gauge with frame work including separating frame work
and putting wire gauge into rolls. Sqm. 0.48
8.34 Dismantling Rain water pipes of A.C.C/C.I pipe with clamps and specials
etc. Metre 1.05
8.38 Removing doors and windows together with the dismantling of walls
1 2 3 4
(i) Unless otherwise stated, the labour rates include handling of all materials within 100 metres.
(ii) Where-ever smooth exposed concrete finish is desired 33-1/3 percent extra on the labour rates
except for item No. 9.17 shall be payable. The through rates shall be increased correspondingly.
(iii) Deleted
(b) Prior approval of the Chief Engineer should be obtained for getting this work as executed.
Unit
1 2 3 4 5 6 7
9.1 Centring and shuttering for flat surface such as
Suspended floors, Roofs, Landing, Chhajjas,
Shelves etc. Sqm. 16.20 17.80 37.00 39.00
Unit
1 2 3 4 5 6 7
9.9 Centring and Shuttering for R.C.C. domes. 53.00 58.00 605.00 611.00
Sqm.
9.11 Shuttering for precast R.C.C. battens. 4.80 5.30 12.00 12.50
Sqm.
9.13 Centring and shuttering for arches of verandah 7.40 8.60 13.50 14.50
openings Per Mtr.
of clear
span.
9.14 Centring and shuttering for arches of doors and 3.90 4.30 7.20 7.60
windows. Per Mtr.
of clear
span.
(b) Above 3Metres Span but upto 6 Metres Sqm. 21.50 24.00 47.00 49.00
Span.
9.16 Form work for cement concrete blocks, in-situ such
as staggered R.C blocks arrows and plain cement
concrete blocks. Sqm. 7.90 8.80 20.50 21.00
9.17 Extra for steel shuttering pattern as specified by the Sqm.of - - 17.00 20.00
Engineer-in-charge. surface
area
(a) For square, rectangular, polygonal wells. Sqm. 7.50 8.20 25.00 26.00
Unit
1 2 3 4 5 6 7
9.20 Extra for shuttering where any single storey height
exceeds 4 metres in height for every additional
height of 2 metres or part thereof (except for item
No.9.17). Sqm 1.00 1.00 1.00 1.00
CONCRETE
Notes :-
(i) Unless otherwise stated, the labour rates include the rehandling charges of material within 100
metres.
(ii) The labour and through rates include the cost of water. Where water is supplied by the department,
the rate shall be decreased accordingly.
(iii) The laboure rates as well as through rates of concrete include the cost of curing. Wherever curing
is got done departmentally and not through the contractor, the rates shall be reduced by Rs. 2.00
per cu.m
(iv) The rates given below are for hand-mixed concrete. In case mechanical mixer is employed
departmental at Government expense, the labour as well as through rates shall be decreased by
Rs. 4.00 per cum.
(vi) (a) The rates given in item no. 10.15 is for work done up to a height of 4 metres above plinth level
or upto the first storey roof top level which ever may be lower.
(vii) To the extent the plinth area of an inter floor remains within and upto 40 percent of the plinth area
of the main storey of the building immediately below the said inter-floor such an inter floor should
be regarded as mezzanine and if plinth area of the said inter-floor exceeds this limitting figure of 40
per cent then the said inter-floor should be regarded for purposes of note (vi) above as a regular
storey. A mezzanine floor is not to be regarded as a separate additional storey in the structure for
purposes of allowing extra rate for concrete work under item no. 10.15. In the case of building
storey having such a mezzanine, therefore, the storey shall be considered for the full height
ignoring the existence of the mezzanine inter-floor.
(viii) The rates given below are for both cast-in-situ and precast work. The precast work includes the
cost of hoisting and fixing in position.
(ix) Deleted
(x) The rates for all items exclude the cost of steel reinforcement and form work/centring and
shuttering except for item No. 10.38, rate of which includes the labour and material for centring and
shuttering complete.
(xi) The labour rates given in this chapter include the cost of water, Tools and Plant, Scaffolding
(Labour and material) and cost of good earth for mud mortar, wherever required.
(xii) Deleted
(xiii) Coarse sand for item No. 10.10 to 10.15, 10.25, 10.26, 10.27 & 10.38 shall be as per Punjab PWD
Specifications No.3.30.
(xiv) Deleted
(xvii) Deleted
(xx) For estimate purposes cement contents may be taken as under (but payment will be made after
adjusting cement content as per mix design approved by the Engineer-in-charge) :-
(a) For M-20 grade concrete @ 375 kg. of cement per cum of concrete.
(b) For M-25 grade concrete @ 425 kg. of cement per cum of concrete
(c) For M-30 grade concrete @ 450 kg. of cement per cum of concrete.
(d) For M-35 grade concrete @ 475 kg. of cement per cum of concrete.
(e) For M-40 grade concrete @ 500 kg. of cement per cum of concrete.
1 2 3 4 5 6 7
10.1 Mud concrete with brick ballast 40mm gauge (in
hilly areas stone ballast 40mm gauge to be used
instead of brick ballast. Cum. 31.00 115.00 38.00 121.00
1 2 3 4 5 6 7
(c) Cement-Fly Ash Concrete 1:2:3:10 (1
Ordinary Portland Cement : 2 Fly Ash : 3
Sand : 10 Brick Ballast 40mm gauge) Cum 40.50 273.50 44.50 277.50
10.12 Deleted
10.13 Extra over item 10.1 to 10.11 for plains and 10.1
to 10.8 for hills above when work is done in situ in
small quantities not exceeding 0.30 Cum. Per
block in situ such as staggered block arrows,
concrete block over inverted filters, bed plates
arches etc.
Cum. 6.00 6.00 6.60 6.60
1 2 3 4 5 6 7
10.15 Reinforced cement cocrete 1:2:4 hand mixed but
excluding steel reinforcement, centering and
shuttering in super structure. Cum. 57.00 461.00 62.00 467.00
10.16 Deleted
10.17 Deleted
10.18 Deleted
10.19 Deleted
10.20 Deleted
10.21 Deleted
10.22 Deleted
10.24 Deleted
10.28 Supplying & Laying dry brick bats. Cum. 5.85 77.00 6.40 78.00
10.29 Supplying & Laying dry brick ballast. Cum. 5.85 89.00 6.40 90.00
1 2 3 4 5 6 7
10.30 Nicking cement concrete surface (Over 28 days
old including preparation and laying slurry). Sqm. 1.05 1.05 1.15 1.15
10.32 Nicking lime concrete surface. Sqm. 0.65 0.65 0.70 0.70
10.35 Preparing surface for inverted filters. Sqm. 0.49 0.49 0.55 0.55
10.37 Deleted
(a) For wells plugged up to top. Cum. 87.00 491.00 93.50 497.50
(b) For well not plugged up to top. Cum. 192.00 596.00 198.50 602.50
10.39 Deleted
1 2 3 4 5 6 7
10.41 Plum cement concrete 1:6:12 with stone ballast
40mm gauge using 20% plum. Cum. 40.50 211.00 44.50 215.00
10.43 Deleted
1 2 3 4 5 6 7
10.49 Extra for P.C.C. work done in subsequent storey
above the first storey upto height of 4 metres or
part thereof upto the roof top level of that storey. Cum 2.00 2.00 2.20 2.20
10.52
Extra for using admixure in designed mix concrete. Kg. --- 45.00 --- 45.00
1 2 3 4 5 6 7
Note:- Rates of item No. 10.52 to 10.55 are based on September 2008.
BRICK WORK
Notes :-
(i) Unless otherwise stated, the labour rates include the cost of rehandling of materials within 100
metres.
(ii) These rates are meant for small engineering works where the total quantity of Brick work does not
exceed 15 cu.m. and for all building works and boundry walls. The labour rates for large
engineering works except building works and boundry walls involving more than 15 cu.m. of brick
work shall be reduced by ten per cent and the through rates shall be reduced correspondingly.
(iii) Through rate for brick work with 2nd class Bricks will be reduced by Rs. 30/- per cu.m, than the
rates with first class Bricks for that item for work.
(iv) The labour rates as well as through rates include the cost of water. In case water is supplied free
by the department, rates will be reduced accordingly.
(v) The rates for brick work done upto 1.5 metres height above the top of foundation concrete in case
of compound walls and in other Engineering works, is the same as for brick work in foundation and
plinth. In case of foundations of bridges, for those with ordinary open foundations, masonry above
top of foundation concrete and in case of well foundations, above top of well cap, for a height of 1.5
metres shall be paid for at the rate, appearing in schedule for masonry, in foundation and plinth.
(vi) Deleted
(vii) The Labour rate given in this chapter include the cost of water, tools and plants, scaffolding
(Labour & Materials) and cost of good earth for mud mortar and mud plaster, where ever required.
(viii) To the extent the plinth area of an inter floor called mezzanine remains within and upto 40 per cent
of the plinth area for the main storey of the building immediately below the said inter floor such an
inter floor should be regarded as mezzanine and if plinth area of the inter floor exceeds this limiting
figure of 40 per cent than the inter floor should be regarded for purpose of item No. 11.29 of this
chapter, as a regular storey. A mezzanine floor is not to be regarded as a separate additional
storey in the structure for purpose of allowing extra rate for brick work under item No. 11.29. In the
case of a building storey having such a mezzanine, therefore the storey shall be considered for the
full height as if ignoring the existence of the mezzanine inter floor.
(ix) Deleted
(x) The through rates, for the requisite mix of the mortar for item No. 11.73 and 11.74 can be arrived at
by adding Rs. 10.50 and Rs. 12.50 respectively for plains zone and Rs. 12.00 and Rs. 14.00
respectively for sub-montainous Zone to be the through rates of brick work in foundation and plinth,
of that mix.
(xi) (a) In case of basement, the masonry for basement floor, above the floor of basement, shall be
payable at the rates of the items of super-structure. For its foundation portion, allow Rs.
8.00 and Rs. 8.80 per cum. for plains and sub-mountainous area, respectively extra in the
foundation rates, for every additional depth of 4 metres or part there of.
(xii) Regarding the payment of extra rate, for subsequent storey above ground level, the structure
above plinth level, on natural ground level, will be considered as first storey.
(xiii) The work of brick masonry, in stone-dust (from crusher) shall only be done, with prior approval of
the competent authority and the rate of brick work in cement sand mortar increased by Rs. 5/- cum
correspondingly.
(xiv) Ground hydrated lime shall be used in all items of brick work in lime mortar.
(xv) For brick work under water, the pumping out of water shall be carried out departmentally.
11.28 Gilafi work as per item No. 11.27 with Jibi face
(outer 5cm laid in cement, sand mortar 1:5)
including striking joints. Cum. 65.00 244.00 71.00 251.00
Note : Deleted
(a) Upto 1.5 metres span Cum. 29.50 48.00 32.50 51.00
Note :- Deleted
11.65 Dressing, chamfering of bricks to required 100 36.50 36.50 40.00 40.00
shape in masonry work. Nos
11.66 Replacing kallar eaten bricks. Each 0.90 1.60 0.95 1.70
11.67 Labour for brick work laid dry in walls Cum. 21.00 21.00 23.00 23.00
11.77 First Class burnt clay Fly Ash Brick work laid in
cement sand mortar in foundations and plinth
(i) Cement Sand Mortar 1:7 Cum 49.50 352.00 54.00 357.00
(ii) Cement Sand Mortar 1:6 Cum 49.50 362.00 54.00 367.00
(iii) Cement Sand Mortar 1:5 Cum 49.50 374.00 54.00 379.00
(iv) Cement Sand Mortar 1:4 Cum 49.50 388.00 54.00 393.00
(v) Cement Sand Mortar 1:3 Cum 49.50 420.00 54.00 425.00
11.78 First Class brunt clay Fly Ash brick work laid in
cement sand mortar in first storey upto 4
metres) above plinth level.
(i) Cement Sand Mortar 1:7 Cum 70.00 372.00 77.00 379.00
(ii) Cement Sand Mortar 1:6 Cum 70.00 382.00 77.00 389.00
(iii) Cement Sand Mortar 1:5 Cum 70.00 394.00 77.00 401.00
(iv) Cement Sand Mortar 1:4 Cum 70.00 409.00 77.00 416.00
(v) Cement Sand Mortar 1:3 Cum 70.00 440.00 77.00 447.00
(vi) Cement Sand Mortar 1:2 Cum 70.00 491.00 77.00 498.00
11.79 115mm thick clay fly ash brick wall with every
fourth course reinforced with hoop iron laid in
cement sand mortar 1:4 in super structure.
Sqm 13.00 57.00 14.50 58.00
STONE MASONRY
Notes :-
(i) The labour rates include the cost of water, tools and plant, labour and materials for scaffolding and
centring and shuttering wherever required and cost of good earth for mud mortar where required.
(ii) Unless otherwise stated, the labour rates include the rehandling of materials within 100 metres.
(iii) The rates include the cost of water. Where the water is supplied free by the Department, rates shall
be decreased accordingly.
(iv) The labour rates including the cost of dressing stones according to the relevent PWD Specifications.
(v) The labour as well as through rates for item nos. 12.11, 12.12, 12.13, 12.16 to 12.24, 12.28 to 12.33
are applicable when quarried stone is used. When work is built with small boulders or with stone
obtained by breaking large boulders, the above rates will be increased by Rs. 30.00 per cum on
account of extra labour involved in dressing.
(vi) The through rate of the stone masonry, include the cost of stone at the site of work irrespective of
the distance from the source, but stone masonry will normally be constructed in such area, where
stone is available locally, or in the vicinity of the site of the work. Variations in actual lead in such
cases will be taken care of, by premium/abatement over the schedule rates. Where, however stone
is not available near at hand but has to be brought from long distances, item of stone masonry
should not be specified, and if, some work has to be constructed in stone due to very special
reasons, extra provision for carriage of stone should be made in the estimates.
(vii) If pumping is required in wet stone masonry work, it will be done departmentally.
Sr. No. Description Unit Plains Sub-Mountionus
Labour Through Labour
Rate Rate Rate
1 2 3 4 5 6
ASHLAR MASONARY
1 2 3 4 5 6
12.7 Extra for above items for every additional storey of
height upto 4 metres above the top of structural
roof of lower storey. Cum. 18.00 18.00 19.00
1 2 3 4 5 6
1 2 3 4 5 6
12.31 Random rubble masonry or polygonal rubble
masonry (Kentish Rag) or random or polygonal
rubble built to courses in foundations and plinth in
mud mortar Cum. 86.00 157.00 95.00
1 2 3 4 5 6
12.43 Stone filling behind retaining walls. Cum. 14.00 46.00 15.50
DHAJJI WALLING
te of work irrespective of
ucted in such area, where
ons in actual lead in such
es. Where, however stone
s, item of stone masonry
tone due to very special
ates.
ntally.
Sub-Mountionus
Through
Rate
1325.00
1302.00
988.00
946.00
956.00
914.00
19.00
75.00
1892.00
1879.00
764.00
748.00
736.00
14.50
67.00
349.00
328.00
314.00
208.00
152.00
367.00
347.00
333.00
216.00
29.50
15.00
73.00
280.00
290.00
301.00
156.00
159.00
314.00
153.00
30.00
12.00
47.00
307.00
293.00
31.40
64.00
(i) Unless otherwise stated, the labour rates include handling of material within 100 metres.
(ii) The rates for hoisting are for heights upto 4 metres above plinth. For every additional 4 metres
height or part thereof, add 10 per cent on item Nos. 13.1 to 13.5 and add 20 per cent on item Nos.
13.6 to 13.9.
(iii) The rates for hoisting are not to be paid over and above the rates for manufacture of beams
battens, etc., as given in other chapters as these rates already include hoisting charges.
(iv) The labour rates given in this chapter include the cost of water, tools and plant, scaffolding (Labour
and meterial) and cost of good earth for mud mortar and mud plaster wherever required.
(v) For item No. 13.9 for bridge girders having spans more than 15 metres, special rates will be worked
out and paid for on the merits of each case.
(vi) The rates for item Nos. 13.62 to 13.69 exclude the cost of beading and frame work for base which
is to be paid for separately.
(vii) The rates given are for single storey. For every additional storey of 4 mtr. or part add Rs. 0.30 per
sqm. for item No. 13.11, 13.13, 13.14 and 13.17.
Sr. No. Description Unit Plains Sub-Mountainous
Region
Labour Through Labour Through
Rate Rate Rate Rate
1 2 3 4 5 6 7
13.1 Hoisting R.C.C lintel and placing in position. Cum. 70.00 70.00 77.00 77.00
13.2 Hoisting R.C.C battens and placing in position. Cum. 95.00 95.00 104.00 104.00
13.3 Hoisting R.C.C shelves and placing in position. Cum. 56.00 56.00 62.00 62.00
13.5 Hoisting wooden battens and placing in position. Cum. 66.00 66.00 72.00 72.00
13.6 Hoisting wooden beams and placing in position. Cum. 42.00 42.00 46.50 46.50
13.7 Hoisting wooden trusses and placing in position. Cum. 193.00 193.00 212.00 212.00
13.8 Hoisting R.S joists and placing in position. Qtl. 16.00 16.00 17.00 17.00
Roofing
13.54 Extra for bitumen painting @0.69 Kg. per Sqm. Sqm. 0.38 2.70 0.42 2.70
CEILINGS
13.64 Providing and fixing Dasuty cloth ceiling. Sqm. 4.00 22.50 4.40 23.00
13.65 Providing and fixing hessian cloth ceiling. Sqm. 4.00 12.80 4.40 13.20
13.66 Providing and fixing plywood ceiling. Sqm. 3.15 57.00 3.50 58.00
(i) Unless otherwise stated, the labour rates include the handling charges of materials within 100
metres.
(ii) The rates include the cost of water. Where the water is supplied free by department, the rates shall
be decreased accordingly.
(iii) The rates given are for ground floor, for every additional storey add Rs. 0.30 per sqm.
(iv) The labour rates given in this chapter include the cost of water, tools and plants and cost of good
earth for mud mortar and mud plaster wherever required.
(v) Coarse sand (fine aggregate) for 1:2:4 concrete in item of conglomerate, polished and terrazo
flooring shall be as per Punjab PWD Specifications No.3.30.
(vi) For square and rectangular columns, enhance the labour rate for item No. 14.28 to 14.32 by 33.3
per cent. For round and eliptical columns, enhance the labour rates for the item No. 14.28 to 14.32
by 100 per cent. The through rates are to be increased accordingly.
(vii) Risers of stair-case are to be paid as per skirting or dado rates while treads and landings are to be
paid as per flooring rates of similar specifications.
(viii) The rates for rubbing and polishing to granolithic finish are for rubbing & polishing to granolithic
grenite finish.
Sr. No. Description Unit Plains Sub-mountainous
Region
Labour Through Labour
Rate Rate Rate
1 2 3 4 5 6
14.1 Base course of floor consisting of 100mm thick
cement cocrete 1:8:16 and 100mm sand filling.
Sqm. 4.30 27.00 4.75
14.11 Deleted
14.33 Extra over item No. 14.22 and 14.28 for plains if
33 percent white cement in 6mm thick top layer
is used.
Sqm. -- 11.80 --
14.48 Deleted
14.49 Deleted
14.51 Deleted
14.52 Deleted
Note:- Rates of item No.14.77 and 14.78 are based on September, 2008.
30 per sqm.
Sub-mountainous
Region
Through
Rate
7
27.00
4.00
19.00
25.00
29.00
46.00
52.00
56.00
12.50
10.50
50.00
38.00
44.00
36.00
22.00
35.50
38.50
62.00
73.00
27.50
62.00
74.00
80.50
79.00
91.00
103.00
76.00
95.00
109.00
91.00
109.00
127.00
91.00
109.00
126.00
54.00
62.00
75.50
83.00
79.00
92.00
105.00
76.00
96.50
110.50
91.00
110.00
129.00
91.00
110.00
129.00
11.80
--
--
--
--
--
--
78.00
59.00
62.00
66.50
70.00
83.00
89.00
85.00
92.00
91.00
89.00
90.00
89.00
91.00
206.00
251.40
343.30
477.50
228.20
312.70
398.90
283.10
405.80
497.80
273.50
497.80
237.70
329.80
464.00
214.50
299.00
385.20
269.40
392.10
484.10
259.90
392.10
484.10
250.00
216.50
230.00
202.40
225.50
230.00
960.00
62.50
220.00
179.00
235.00
1114.30
1387.80
127.00
129.00
299.00
459.00
420.00
66.00
63.00
73.00
7.00
263.00
227.00
3.10
3.00
2.70
4.65
3.40
3.10
2.80
---
5.95
172.40
190.70
139.35
738.00
856.00
717.00
8.
(i) Unless otherwise stated the labour rates include the rehandling of materials within 100 metres.
(ii) The rates include the cost of water, where the water is supplied free by department, the rates shall
be reduced suitably.
(iii) The rates for plastering, pointing, white washing, distempering and decorative cement based paint
given below are for superstructure upto 4 metres height whether the first storey or the subsequent
storeys. In case any single storey exceeds 4 metres height (as in case of overhead-reservoir and
outer face of walls etc.) the labour as well as through rates of plaster and pointing shall be increased
by 0.20 per Sqm. for white washing and colour washing Rs. 0.05 per sqm and for distempering,
decorative cement based paints by Rs.0.10 per sqm for every additional height of 4 metres or part
thereof.
(iv) The labour rates for item no. 15.45 to 15.49 include the cost of Earth, Bhusa and Gobri etc.
(v) Rates for distempering with dry and oil bound distemper have been provided in this chapter. These
rates have been based on superior quality distempers, manufactured by standard firms. The use of
inferior distempers and Country frisco shall not be permitted as they never give proper quality of
lasting surface.
(vi) The rates of lime plaster and pointing in this chapter have been worked out on the basis of lime
putty.
(vii) Work against items of filling i.e. on 15.66 and 15.67 shall be got done only after written approval of
the Engineer-in-charge.
(viii) The labour rates given in this chapter include the cost of water, tools and plant and scaffolding all
types of sundries etc. labour and materials.
Sr. No. Description Unit Plains Sub-Mountainous
Region
Labour Through Labour
Rate Rate Rate
1 2 3 4 5 6
15.1 6mm thick cement plaster 1:2. Sqm. 5.50 10.50 6.00
15.2 6mm thick cement plaster 1:3. Sqm. 5.50 9.70 6.00
15.3 6mm thick cement plaster 1:4. Sqm. 5.50 8.70 6.00
15.4 10mm thick cement plaster 1:2. Sqm. 5.50 13.00 6.00
15.5 10mm thick cement plaster 1:3. Sqm. 5.50 12.00 6.00
15.6 10mm thick cement plaster 1:4. Sqm. 5.50 10.50 6.00
15.7 12.5mm. thick cement plaster 1:2. Sqm. 5.80 16.00 6.40
15.8 12.5mm thick cement plaster 1:3. Sqm. 5.80 14.00 6.40
15.9 12.5 mm thick cement plaster 1:4. Sqm. 5.80 12.00 6.40
15.10 12.5mm thick cement plaster 1:5. Sqm. 5.80 11.00 6.40
15.11 12.5mm thick cement plaster 1:6. Sqm. 5.80 10.00 6.40
15.12 12.5mm thick raised cement mortar band/drip 0.24 0.32 0.26
per
course in cement mortar 1:3
metre
long &
per
cm.
wide
15.13 12.5mm thick raised cement mortar band/drip 0.24 0.30 0.26
course in cement mortar 1:4 per
metre
long &
per
cm.
wide
15.16 20mm thick cement plaster 1:4 in two coats work. Sqm. 8.40 18.00 9.20
15.19 12.5mm thick lime surkhi sand plaster 1:1:1 Sqm. 5.60 11.80 6.20
15.20 12.5mm thick cement lime plaster 1:1:6 Sqm. 5.80 12.00 6.40
15.21 12.5mm thick lime surkhi plaster 1:2 Sqm. 5.60 13.00 6.20
15.23 20mm thick cement plaster 1:6 in two coats work. Sqm. 8.40 15.00 9.20
15.26 25mm thick cement plaster 1:2 in two coats work. Sqm. 8.40 29.00 9.20
15.27 25mm thick cement plaster 1:3 in two coats work. Sqm. 8.40 25.00 9.20
15.28 25mm thick cement plaster 1:4 in two coats work. Sqm. 8.40 21.00 9.20
15.29 25mm thick cement plaster 1:5 in two coats work. Sqm. 8.40 18.50 9.20
15.30 25mm thick cement plaster 1:6 in two coats work. Sqm. 8.40 17.00 9.20
Plastering on Floors
Miscellaneous
Pointing
15.61 White Washing (First coat or subsequent coat). Sqm. 0.34 0.55 0.37
Distempering
Sub-Mountainous
Region
Through
Rate
7
11.00
10.00
9.30
13.50
12.50
11.00
16.50
14.50
12.50
11.50
10.50
0.34
0.33
24.50
21.50
19.00
17.00
0.49
12.00
12.50
13.50
14.50
15.50
18.00
22.00
29.50
26.00
22.00
19.50
18.00
13.00
11.50
16.00
14.00
11.50
10.50
13.50
12.50
14.00
0.90
4.45
19.50
26.50
24.50
44.00
14.30
4.55
5.40
3.55
4.30
0.50
9.80
10.50
9.90
6.90
10.50
16.50
4.75
7.70
6.20
6.10
4.70
0.60
0.95
1.30
0.65
1.00
3.80
12.70
6.70
2.30
4.20
8.90
3.30
6.00
10.50
3.70
(i) Unless otherwise stated, the labour rates include handling of all materials within 100 metres.
(ii) Deleted
(iii) The special quality paints will be first quality paints manufactured by reputed firms like Nerolac,
Asian, Berger, J&N, ICI or equivalent, approved by the Engineer-in-Charge.
(iv) The labour rates given in this chapter include the cost of tools and plant and scaffolding (labour
and material) wherever required.
(v) The rates given in item No. 16.48, 16.49, 16.50, 16.51, 16.54, 16.55, 16.56 and 16.57 are inclusive
of printing.
Sr. No. Description Unit Plains Sub-Mountainous Region
1 2 3 4 5 6 7 8 9
(A) Painting on Wooden surface etc.
1 2 3 4 5 6 7 8 9
16.5 Painting two coats with synthetic enamel
paints in all shades on old wood work or
metallic or plastered or concrete surface
to give an even shade including rubbing
down old paint.
Sqm. 2.10 8.00 4.90 2.30 8.20 5.10
1 2 3 4 5 6 7 8 9
16.14 Painting two coats on iron sheets with
roofing red readymixed paint on new
work to give an even shade. Sqm. 2.25 6.30 4.90 2.50 6.50 5.20
1 2 3 4 5 6 7 8 9
16.24 Preparation of plastered or concrete
surface for painting, including sand
papering the suface, applying one coat
of linseed oil and filling with approved
quality filler, consisting of white lead
linseed oil, varnish and Chalk mitti
including finishing surface to the required
finish complete.
Sqm. 3.00 14.00 - 3.30 14.00 -
(D) Miscellaneous
16.30 Burning old paint with blow lamp. Sqm. 2.00 2.50 - 2.25 2.80 -
16.33 Painting one coat with solignum. Sqm. 0.65 - 1.30 0.70 - 1.40
16.34 Painting two coat with solignum. Sqm. 0.95 - 2.20 1.05 - 2.25
1 2 3 4 5 6 7 8 9
16.35 Varnishing with copal varnish one coat of
sizing and two coats of varnishing on
new wood work including stopping. Sqm. 2.45 9.10 6.00 2.70 9.30 6.20
16.37 Oiling wood work with raw linseed oil. Sqm. 0.32 - 1.25 0.35 - 1.25
16.39 Painting one coat with creosote. Sqm. 0.65 - 1.10 0.70 - 1.15
16.40 Painting two coat with creosote. Sqm. 0.95 - 1.70 1.05 - 1.80
16.41 Coal tarring one coat Sqm. 0.80 - 2.70 0.90 - 2.80
16.42 Coal tarring two coats Sqm. 1.20 - 4.00 1.30 - 4.15
16.43 Bee's wax polishing on new wood work. Sqm. 4.35 - 6.60 4.80 - 7.10
16.44 Bee's wax polishing on old wood work. Sqm. 1.60 - 2.75 1.80 - 2.95
16.46 Spirit polishing one coat on old work. Sqm. 3.55 - 4.90 3.90 - 5.20
16.47 Painting new letters and figures of black cm. 0.13 - 0.14 0.14 - 0.15
synthetic enamel paint to give an even height
shade. per
word
16.48 Repainting letters and figures of black cm. 0.085 - 0.092 0.094 - 0.10
synthetic enamel paint to give an even height
shade. per
word
1 2 3 4 5 6 7 8 9
16.50 Painting sounding rods and other
gauges reading to centimetre with
synthetic enamel paint :-
1 2 3 4 5 6 7 8 9
16.56 Painting kilometre stone with synthetic
enamel paint :-
(iii) Kilometre Stone on village roads. Each 16.50 - 18.50 18.00 - 20.50
(iii) Kilometre Stone on village roads. Each 25.00 - 28.50 28.00 - 31.00
(i) Unless otherwise stated, the labour rates include rehandling of materials within 100 metres.
(ii) Unless otherwise stated, the labour and through rates include all wastage of timber in sawing and
cutting and sawing charges including carriage to and from saw mills.
(iii) Through rates for items requiring use of wire gauge include the cost 140G gauge galvanised wire
gauge.
(iv) The labour rates given in this chapter include the cost of tools and plants and scaffolding (Labour
and material) whereever required.
(v) The rate for item No. 17.4 to 17.9 apply to simple wood work not involving any jointing such as
beams battens etc. where jointing is involved as in case of roof trusses composite beams, etc.,
increase the labour and through rate by Rs. 300/- per cu.m. In case of built -in-fixtures involving
jointing increase the rates by Rs. 200/- per cum.
(vi) Ther rates for item No. 17.13,17.14,17.21, 17.23 exclude the cost of sliding bolts, Tower bolts,
handles but include the cost of labour for fixing them.
(vii) In case fixed glazing is continuous to openable shutter, the area of fixed glazing will be measured
up to central line of mullion, if the area of fixed glazing exceeds 25per cent of the openable area,
otherwise the whole area shall be measured as openable and paid for as such.
(viii) If frosted glass is used instead of ordinary glass, the through rate in item No. 17.34 and 17.35 shall
be increased by Rs. 8/- per sqm. If in case of item No. 17.19, 17.20, 17.27 and 17.28 frosted glass
is used, extra payment shall be made over and above the through rate of these items at Rs. 8.00
per sq.m. of actual area of glass panes.
(ix) The rates for aluminium fittings, as provided in this chapter, are only for the purposes of estimating
and not for purchasing of fittings through contractor. All aluminium fittings shall be arranged by the
department, and supplied to contractor free of cost for fitting.
(x) The wood work in chowkats of doors and windows shall be done at site, strictly as per P.W.D
Specifications, Nothing extra shall be paid for wastage, or for dimensions, supplied beyond those
specified and for horns. The length of each piece shall be measured overall, so as to include the
projection for lenons. In case of mouldings, roundings circular rebates, circular and varying
sections, the sectional area of the piece shall be taken as the area of the least square or rectangle
from which such section can be cut, and nothing extra shall be paid for such moulding and
rebates.
Note :- Rates of item No. 17.54, 17.55, 17.56 & 17.57 are based on September 2008.
Sub-Mountainous Region
Through
Rate
7
--
--
--
--
--
6896.00
6008.00
5098.00
4819.00
11307.00
8593.00
339.00
307.00
275.00
217.00
181.00
100.00
294.00
265.00
231.00
189.00
158.00
127.00
89.00
560.00
507.00
453.00
349.00
296.00
243.00
163.00
361.00
341.00
307.00
393.00
381.00
371.00
311.50
301.50
292.00
281.00
269.00
283.00
275.00
263.50
273.00
266.00
259.00
209.00
189.00
169.00
154.00
238.00
232.00
201.00
199.00
88.00
76.00
178.00
136.00
95.00
83.00
263.00
276.00
293.00
301.00
205.00
219.00
235.00
248.00
237.00
257.00
281.00
191.00
210.00
241.00
145.00
104.00
85.00
104.00
323.00
306.00
169.00
154.00
504.00
478.00
446.00
286.00
258.00
384.00
399.00
415.00
429.00
335.00
356.00
389.00
263.00
191.00
17.00
25.00
4.30
79.00
104.00
152.00
389.00
397.00
405.00
423.00
419.00
436.00
454.00
466.00
483.00
496.00
509.00
523.00
1.00
138.00
92.00
125.00
82.00
456.00
298.00
245.00
161.00
136.00
155.00
167.00
185.00
71.00
88.00
94.00
7.30
6.90
6.40
11.00
9.40
32.50
28.50
24.00
49.50
37.50
33.50
28.50
58.50
7.80
41.50
125.00
40.80
12.25
22.35
30.05
33.95
242.00
258.00
308.00
197.00
236.27
252.78
820.57
855.22
715.30
588.25
1659.71
mber 2008.
(i) The rates in this chapter are for both rivetted as well as welded work.
(ii) The labour and through rates for items Nos. 18.1,18.2,18.3,18.6 and 18.7 are for a height up to 4
metres above plinth. For additional slab of height of 4 metres, or part thereof, the rates for item Nos.
18.1, 18.2 are to be increased by Rs. 2.00 per quintal, and the rates for item Nos. 18.3,18.6,18.7
are to be increased by Rs. 4.00 per quintal.
(iii) The cost of all rivets, bolts and nuts is included in the through rates.
(iv) The labour rates given in this chapter include the cost of tools and plants, welding rods and
scaffolding (labour and material) where ever required. The labour rates also cover the electrical
and gas charges, where welding work is done.
(v) The rates given in item No. 18.17 are also applicable for the item of "tie rod" provided in the well
steining. These rates also includes the cost of flat steel bond ring, threading and welding, whenever
done, complete in all respects. Only bottle nuts are payable as per item No. 18.16.
(vi) Deleted
(vii) Rates for steel boundary gates shall be the same as for the steel roof trusses.
(viii) Unless otherwise stated, the labour rates include handling of materials with in 100 metres.
Sr. No. Description Unit Plains Sub-Mountainous
Region
Labour Through Labour
Rate Rate Rate
1 2 3 4 5 6
18.1 Steel work, fixed independently without
connecting plates, including cutting, hoisting
and fixing in position :-
1 2 3 4 5 6
(a) For roof trusses, well curbs, plates and
trussed girders, etc. of any span for
buildings and bridges upto 15 metres
span. Qtl. 244.00 806.00 269.00
1 2 3 4 5 6
18.9 Providing & fixing G.I. sheet 0.80 mm thick
sliding shutters, with 40mm x 40mm x 6mm
angle iron frame with diagonal braces, 3.15
mm. gusset plates at the junctions, hooks at
the top and 23mm dia pulleys at the bottom
and 40mm x 40mm x 6mm angle iron top and
bottom guides including locking arrangements
with handles etc. complete.
1 2 3 4 5 6
18.14 Providing and fixing 16mm dia metre fan hooks
80 cm long, of required shape and size.
Each 2.50 9.25 2.70
(i) 20mm dia bars and below Qtl. 54.00 598.00 59.00
18.19 Deleted
(a) Upto One Sqm Area Per Kg. 2.50 10.90 2.70
(b) Above One Sqm Area Per Kg. 2.20 10.40 2.40
18.20 Deleted
1 2 3 4 5 6
18.20 Supplying & fixing fixed steel windows of
(i) standard rolled steel sections joints mitred
and electrically flash welded including iron lugs
and glazing clips, labour for fixing during
masonary complete (excluding glazing) and
fixing with two coats of readymixed paint, red
lead non-setting primer.
Per Kg. 2.50 10.40 2.80
18.23 Deleted
1 2 3 4 5 6
1 2 3 4 5 6
2 113mm x 60mm with 35mm wide single
rebate. 3.38 kg.
1 2 3 4 5 6
18.28 Providing and fixing stair case railing made out
of M.S. square bars 20mm x 20mm as vertical
part 0.70 metre high fixed with M.S. base plate
of 40mm x 40mm x 6mm and flat iron 40mm x
6mm as hand rail complete in all respect.
Metre 16.60 92.00 18.30
sses.
th in 100 metres.
Sub-Mountainous
Region
Through
Rate
600.00
616.00
620.00
628.00
830.00
893.00
893.00
924.00
637.00
696.00
311.00
399.00
241.00
134.00
56.00
229.40
23.00
9.50
6.80
14.00
603.00
596.00
689.00
11.10
10.60
10.70
49.50
49.00
58.00
57.50
42.00
41.50
50.00
49.50
98.00
121.00
83.00
0.40
79.00
229.00
94.00
77.25
5.55
738.00
24.20
1.10
LINING
Notes :-
(i) Labour rates for lining items include handling of materials with in 100 metres.
(ii) The cost of water is not included in the following rates except items 19.24 and 19.25 and the water
shall be supplied by the department free of cost.
(iii) The rates for item Nos. 19.1 to 19.6 include the cost of fine dressing to exact level, watering and
preparing sub-grade. All basket earth work to be paid extra at the rates for lip cutting.
(iv) For concrete lining with machine-mixed concrete, rates shall be amended as follows :-
(a) If the machanical mixer is employed departmentally at Government expense, the labour as
well as through rates shall be decreased by Rs. 4.00 per cum.
(b) In case the mechanical mixer is employed at the contractor's expense, the labour as well as
through rates shall be increased by Rs. 6.00 per cum.
Sr. No. Description Unit Plains Sub-Mountainous
Region
(a) hand mixed concrete lining in bed. Cum. 46.50 358.00 51.00
Note :- The rates for item Nos. 19.19 and 19.20 are
included in the rate of item No. 19.13 for
curing and are not payable in addition. These
rates are payable only when curing is done
departmentally and the work of french drain is
got done through contractor.
ed as follows :-
Sub-Mountainous
Region
Through
Rate
7
0.60
0.95
0.90
1.15
1.15
1.50
1.70
1.95
Through
Rate
7
58.00
60.00
61.00
61.00
36.50
36.50
36.50
362.00
Through
Rate
7
366.00
373.00
379.00
54.50
1.80
4.20
0.60
1.90
0.55
16.00
17.50
1.05
0.36
45.00
Through
Rate
7
6.70
4.05
4.45
7.50
8.00
Through
Rate
7
8.70
9.70
10.50
63.00
68.00
42.50
46.00
15.00
Through
Rate
7
11.50
16.00
5.50
OUT LETS
Notes :-
(i) The term "discharge" wherever used in this Chapter means designed full supply discharge of the
parent channel opposite the oulet.
(ii) The labour rates include the rehandling of materials within 100 metres.
Sr. No. Description Unit Plains Sub-Mountainous
Region
(ii) With 'H' more than 0.5m but upto 0.9m Job 67.00 - 67.00
(ii) With 'H' more than 0.5m but upto 0.9m Job 24.50 - 24.50
(ii) With 'H' more than 0.5m but upto 0.9m Job 151.00 - 151.00
Note :- (i) Out lets with 'H' more than 1.10m will
usually be located in main canal and
branches, payment for these should be
based on actual measurements.
(ii) With 'H' more than 0.5m but upto 0.9m Job 209.00 - 209.00
(ii) With 'H' more than 0.5m but upto 0.9m Job 42.00 136.00 42.00
(ii) H' more than 0.5m but upto 0.9m Job 68.00 241.00 68.00
(iii) H' more than 0.9m but upto 1.10m Job 100.00 352.00 100.00
(ii) H' more than 0.5m but upto 0.9m Job 85.00 296.00 85.00
(iii) H' more than 0.9m but upto 1.10m Job 120.00 432.00 120.00
20.6 Extra over item No. 20.3, 20.4 and 20.5 as the
case may be, for adjusting of crest levels of O.F.
and A.P.M. out lets with 1:2:4 cement concrete
when lowering of crest level is involved :--
(b) H' more than 0.5m but upto 0.9m Job 34.00 44.00 34.00
(c) H' more than 0.9m but upto 1.10m Job 45.50 58.00 45.50
20.7 Extra over item No. 20.3, 20.4 and 20.5 as the
case may be for adjusting crest level of O.F. and
A.P.M. outlets with 1:2:4 cement concrete when
raising of the crest level is involved.
(b) H' more than 0.5m but upto 0.9m Job 22.50 32.50 22.50
(c) H' more than 0.9m but upto 1.10m Job 34.00 47.00 34.00
Sub-Mountainous
Region
Through
Rate
7
Through
Rate
7
Through
Rate
7
-
41.00
82.00
Through
Rate
7
136.00
179.00
126.00
241.00
352.00
Through
Rate
7
137.00
296.00
432.00
29.50
44.00
58.00
23.50
32.50
47.00
Through
Rate
7
120.00
222.00
364.00
255.00
353.00
584.00
115.00
146.00
200.00
64.00
30.00
Through
Rate
7
4.05
9.10
23.50
45.00
PILE DRIVING
Notes :-
The rates given in this chapter are for estimating purposes only. The works of sheet piling should
be done departmentaly as far as possible. No firm rate can be provided for sheet piling in view of
the special nature of the job, the rates for which may vary considerably according to site conditions.
(b) exceeding 4.5 metres but upto 7.5 metres. sqm of 8.90
effective
area
Remarks
5
To be done by hand,
crane or ramps
including cost of rope.
WELL SINKING
Notes :-
(i) Unless otherwise specified, the rates cover the cost of all tools, plants, steam hoist, dredger,
pulsometer, gentry and Kentledge etc. as well as loading, unloading of Kentledge and bailing or
pumping of water, where required including removing the excavated soil to a distance of 60 metres.
(ii) In case of running streams or rivers, the spring level will be taken as the low water level in the
stream or river.
(iii) The rates given below do not cover the cost of false masonry and is payable extra at the rates
provided for well-steining in Chapter No.(11)-"Brick Work", if applicable or as per actual work done
and nothing is payable extra on this account.
(iv) The rates of items No. 22.6 to 22.10 are applicable, when the spring level is upto 7.5 metres below
ground level. In case depth of spring level is more than 7.5 metres, but upto 15 metres below ground
level, increase the rates of item No. 22.6 to 22.10, by 50%. If depth of spring level is more than 15
metres, but upto 30 metres, below ground level, increase the rates of item No. 22.6 to 22.10 by 100
per cent.
(v) Where due to presence of boulders, the well sinking is likely to be more difficult and costly, special
rates will be framed by the Superintending Engineer, keeping in view the results of trial bores.
1 2 3 4
22.1 Earth work for digging well in dry excavation from ground level
up to the level where well kerb is placed including depositing
spoil with in 60 metres radius, and filling space, outside the
well, after completion :--
(a) From N.S. Level to 1.5 metres depth. 100 cum 622.00
(b) Exceeding 1.5 metres, but up to 4.5 metres depth. 100 cum 758.00
(c) Exceeding 4.5 metres, but up to 7.5 metres depth. 100 cum 953.00
(d) Exceeding 7.5 metres but upto 12 metres depth. 100 cum 1244.00
22.2 Extra over item No. 22.1 where excavation is done by picks
(such as in soils having admixture of shingle, gravel, moorum,
kanker etc.) 100 cum 228.00
22.3 Lowering steel well in the pit and assembling in position when
depth is more than 4.5 metres from ground level. Quintal 13.00
(a) From 4.5 metres to 7.5 metres below ground level. 100 cum 3586.00
1 2 3 4
(b) Exceeding 7.5 metres but up to 10.5 metres, below
ground level. 100 cum 4759.00
(d) Add for every additional 3 metres depth, or part thereof. 100 cum 1150.00
22.5 Dry sinking of wells in alluvial soil with admixture of clay more
than 20 percent or admixture of kankar up to 15 percent :-
(a) From 4.5 metres to 7.5 metres below ground level. 100 cum 4244.00
(d) Add for every additional 3 metres depth, or part thereof. 100 cum 1378.00
(a) From spring level to 1.5 metres below spring level. 100 cum 7953.00
1 2 3 4
22.7 Wet sinking of wells in soil containing admixture of
kankar/shingle exceeding 15 percent and upto 45 percent or of
clay exceeding 33 percent but upto 50 percent or of both clay
and kankar/shingle exceeding 33 percent but upto 50 percent
(Percentage of kankar/ shingle not exceeding 45) :-
(a) From spring level to 1.5 metres below spring level. 100 cum 10040.00
(a) From spring level to 1.5 metres below spring level. 100 cum 13055.00
1 2 3 4
22.9 Wet sinking of wells in soil containing admixture of
kankar/shingle exceeding 65 percent, but less than 100
percent, or of clay exceeding 70 percent but less than 100
percent or of both clay and kankar/shingle, exceeding 70
percent but less than 100 percent :-
(a) From spring level to 1.5 metres below spring level. 100 cum 16551.00
(a) From spring level to 1.5 metres below spring level. 100 cum 18999.00
1 2 3 4
22.11 Cleaning of silt from wells with bed level upto 15 metres below 223.00
ground level including bailing out water and dredging.
Per cum of
the volume
cleared
inside the
well
(a) From spring level to 3 metres below spring level. 100 cum --
Rates in Sub-
Mountainous
Area
684.00
834.00
1048.00
1369.00
---
14.50
---
---
---
---
---
---
---
---
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
5
--
23344.00
28035.00
33734.00
36845.00
40384.00
48282.00
(a) Loose :-
(b) Compacted :-
23.6 Making 0.75m. dia. and 5.5m. long pilchi rolls for permeable
spurs. Each 22.00 --
23.9 Extra for carriage beyond 2 Km. of pilchi rolls 15cm, dia. 1.5m
long (vide item No. 23.8)
23.12 Surface protection with pilchi mattress lead upto 2.K.M Sqm. 6.50 --
23.14 Rolling pilchi mattress to river edge and floating after unrolling
:-
23.16 Special kahi revetment double lead upto 2 K.M. Sqm. 12.00 --
23.18 Gachi pitching (done with silt clearance and berm dressing)
with thickness of 30cm. (joints to be broken) Sqm. 5.60 --
(ii) Driving pegs 1.0m. long 5 cm. dia 100 Nos 9.70 --
(b)(i) Pegs 1.25m. long 7.5 cm. dia. sharpened at one end. 100 Nos 22.00 --
(ii) Driving pegs 1.25m. long 7.5 cm. dia. 100 Nos 13.00 --
(ii) Driving pegs 1.5m. long 7.5 cm. dia. 100 Nos 14.00 --
(d)(i) Pegs 2m long 7.5 cm dia. sharpened at one end. 100 Nos 33.00 --
23.22 Filling cement bags with sand or earth and sewing including
cost of strings. 100 Nos 23.00 --
23.23 Loading cement bags filled with sand or earth into trucks or
boats within 100 metres. 100 Nos 26.00 --
(b) 2nd to 4th chain per chain of 30 metres. 100 Nos 2.40 --
(c) 5th and subsequent chains per chain of 30 metres. 100 Nos 1.60 --
23.25 Unloading from boats, bags filled with sand and :--
23.26 Filling cement bags with sand sewing and laying in position
within 30 metres in dry, including cost of strings. 100 Nos 46.00 --
23.27 Filling cement bags with sand sewing and laying in position
within 30 metres in water, including cost of strings. 100 Nos 75.00 --
23.29 Weaving wire netting for wire crates including binding sides
and partitions to make crate of 15 cm x 15 cm or 25cm x 7.5
cm mesh. Sqm. 3.65 --
23.30 Filling brick bats in crates and hand packing. Cum. 4.55 --
23.32 Filling stones or spalls into crates and hand packing. Cum. 12.00 --
23.34 Opening out old wire crates and remaking after filling. Sqm. 1.25 --
23.36 Filling spaces and foundations with old stones obtained from
dismantling including labour for dismantling. Cum. 23.50 --
23.40 Extra for anchoring boat for dumping in position. Cum. 2.00 --
(b) When stones are more than 23cm square but under
45cm square Sqm. 1.60 --
23.47 Sand grouting stone apron with high pressure hose. Sqm. 0.80 --
ROAD WORK
Notes :-
(i) The labour rates, given below include the cost of working of road machinery including Washouts,
cost of fuel, lubricants, stores, establishment, depreciation and interest charges. In case the
machinery is provided by the Department, the working cost, as mentioned above shall be
recovered from the contractor at the rates fixed by the Department.
(ii) Unless otherwise stated, the labour rates include rehandling of materials within 100 metres.
(iii) The rates include the cost of water, where water is supplied free by the Department, the rates shall
be reduced suitably.
1 2 3 4 5 6 7
24.1 Preparation of Sub Grade including
trenching, rought dressing of spoil, final
dressing of earth to give level and camber,
watering, rolling with a road roller and
compacting the bed.
100 sqm. 78.00 -- 79.00 --
1 2 3 4 5 6 7
24.4 Laying and consolidation of stabilized soil
sub base or wearing course, with admixture
of any per centage of lime, by weight
including 30 to 50 percent brick ballast,
including digging of earth, stacking of soil,
pulverization, dry mixing, levelling and
watering, wet mixing of soil, lime and brick
ballast, manually or by tractor, with disc
harrow, including pouring of mixture, and
bringing to camber, including sprinkling of
water on the sub base, wearing course, and
rolling, including curing with water, complete,
all operations, but excluding the cost of brick
ballast and lime.
cum 20.00 -- 21.00 --
24.8 Deleted
1 2 3 4 5 6 7
24.9 Providing brick edging (6.83cm wide) laid
length-wise (22.86cm long) with half brick
deep including excavation refilling and
disposal of surplus earth lead upto 50
metres.
Metre 0.17 2.35 0.19 2.57
1 2 3 4 5 6 7
24.14 Laying and consolidation of over gauge
stone metal soling coat (90 mm to 40 mm
gauge grading No. 1 as per MORT&H, Road
Wing specifications No. 404.25) to water
bound macadam specifications, including
making side dowels, carrying the stone
metal from stacks, and spreading to
templates, screening and spreading the
binding material and consolidation the stone
metal and binding material to proper camber,
with road roller, excluding the cost of
templates, barriers and lighting
arrangements and Chowkidars.
cum 22.50 -- 23.50 --
1 2 3 4 5 6 7
1 2 3 4 5 6 7
24.26 Laying asphaltics concrete, on road,
including mixing bajri and bitumen, with
mechanical mixer, carriage of premixed
material, from plant site, to site of work, and
laying the same, with paver, and rolling it,
with road roller, including the cost of
establishment and setting up field laboratory,
for quality control, lighting arrangements,
sign-board and chowkidar, but excluding the
coat of tack coat and seal coat.
1 2 3 4 5 6 7
24.32 Scarifying old kankar metalled crust up to
150mm thick with road roller, including
picking up scarified material, screening and
stacking old useful metal. 100 sqm. 110.00 -- 115.00 --
(iii) kilometre stone on village roads Each 16.00 81.00 18.00 83.00
1 2 3 4 5 6 7
24.40 Providing and fixing premoulded bituminous
joint filler for expansion joints including the
Per metre
cost of sealing compound and primer coat per cm.
12.5 mm wide. depth 0.043 1.35 0.047 1.40
MAINTENANCE OF FURNITURE
Sr. No. Description Unit Labour Rate
(Rs.)
1 2 3 4
25.1 Spirit or Wax polishing .
(a) Tables
(b) Chairs
1 2 3 4
25.4 Washing
1 2 3 4
(f) Pillow cover Each 0.50
25.5 Upholstering
1 2 3 4
25.10 Cleaning of joinery with surf, soda and application of oil Sqm. (To be
there after. measured on
both sides) 0.50
25.12 Cleaning and polishing brass fittings with brasso. Each 0.40
25.17 Providing and fixing curtain rail 1.90cm chrome-plated Metre 20.00
with end bracket. including sockets and
brackets.
1 2 3 4
25.19 Providing and fixing plastic rings 3.80cm. dia. With hooks
for curtains. 100 Nos. 30.00
13.00
19.50
6.00
3.00
6.00
19.50
7.20
7.50
6.00
6.60
9.00
9.00
9.00
15.00
9.60
16.00
4.50
6.00
9.60
4.50
1.50
9.00
1.50
14.00
15.00
15.00
--
60.00
51.00
30.00
22.00
22.00
1.50
12.00
48.00
--
--
--
--
--
--
--
--
--
--
42.00
84.00
--
--
--
--
84.00
48.00
--
--
--
--
--
--
--
--
--
--
--
--
--
--
15.00
--
--
--
--
including sockets and
brackets.
--
--
MISCELLANEOUS
Notes :-
(i) The rates given below are labour rates unless otherwise stated.
(ii) Unless otherwise stated, the labour rates include rehandling of materials with in 100 metres.
1 2 3
26.1 Laying linking and packing tramway tracks. Metre
26.2 Linking B.G track including packing, straightening and levelling. Metre
26.3 Linking points and crossing complete with level fastening. Each
1 2 3
(b) Above 75mm dia. but not exceeding 100mm dia. bores
26.13 Fixing F.I gauges flush with masonry including cost of hooks. Metre
26.15 Cutting down trees, filling holes and levelling of ground, lopping
branches trimming, removal not exceeding 100 metres stacking
clearing site.
(c) girth more than 120 cm. but up to 180 cm. Each
(d) girth more than 180 cm. but up to 250 cm. Each
Note :- (i) The girth is to be measured 1.25 metres above ground level.
1 2 3
(iv) Where these have not been sold, the trees cut and removed
will be the property of the Govt.
26.16 Felling trees, cutting and stacking fuel wood from plantation. Qtl.
26.18 Burning charcoal including loading and unloading and repairs to kiln. Per Qtl. of
charcoal
26.19 supply of wooden bumping posts including labour for cutting from
canal or road plantation making and fixing at site. Each
26.20 Supply of wooden pegs for levelling work from canal or road
plantation 40 mm to 50mm dia and 15cm to 23 cm long. 100 Nos.
26.21 Supply of wooden pegs for alignment work, 40 cm long 75mm dia
from canal or road plantation. 100 Nos.
26.24 Supplying tripod with flages including iron shoes and flag 40 cm.
square and bamboo painted black and white. Each
26.29 Making Sirki Sarkanda Temporary Godown, 3mx3m with walls 2.5m
height 1½ brick thick burnt bricks laid dry, excluding the cost of bricks,
but including the cost of other materials. Each
1 2 3
Note :- The above rates are payable only where water is not available locally
and where fixing of hand pump is neither feasible nor practically
possible due to small amount of work and where water is actually
carried by carts or by mechanical transport.
26.32 Digging pits and fixing distance marks or boundary stones. Each
26.35 Filling 200 litres drums with diesel oil (not payable to diesel dealer) Each
Notes :- (i) The rates are applicable to areas acquired for new canals,
and drains, extension of channels and for construction of
roads and Buildings.
(iii) The rates of item Nos. 26.36 to 26.38 are for estimating
purposes only. The work will be got done departmentally.
26.38 Jungle clearance on running canals and branches, and drains with
discharge more than 9 Cum./s.
1 2 3
26.39 Filling loose cement bags in empty cement bags weighing, sewing
and stacking with in 30metres. Bag
26.40 Filling cement bags with steam coal or kankar lime, sewing including
cost of string. Cum.
26.43 Stencilling (Height of stencil not less than 7.5cm) of bitumen and other
drums. 100 Nos.
Rate
(Rs.)
4
1.60
5.20
240.00
0.80
8.00
15.20
1.00
8.00
3.20
1.20
8.00
10.40
26.40
39.20
13.20
32.80
39.20
18.40
32.80
39.20
20.80
39.20
46.00
3.20
3.20
16.00
13.20
4.00
20.00
36.00
72.00
120.00
5.20
8.40
21.60
8.00
20.00
80.00
20.00
4.00
2.40
36.00
4.00
5.20
20.00
5.60
320.00
2.80
5.60
0.40
0.80
80.00
2.00
50.80
356.00
1.60
80.00 to
393.00
104.00 to
160.00
160.00 to
208.00
208.00 to
264.00
640.00
800.00
1600.00
0.40
11.60
4.80
2.00
10.00
QUANTITIES OF MATERIALS
Note :-
1 2 3 4 5 6
lime Surkhi
(Kg.) (Cum)
Lime Surkhi
(Cum) (Cum)
Lime (kg)
Paints( I.S.I
mark)
(Litres)
27.21 Painting :-
Paints( I.S.I
mark)
(Litres)
Timber (Cum)
27.30 Filling stone in wire-crates (hand 3.3kg per sqm of wire netting 15cm
packed) Cum 1.00 mesh.
Stone
(Cum)
27.31 Stone pitching. Cum
1.00 Shingle
or stone
aggregates
(10mm) ring
Cement Mortar
(cum)
Bricks (Nos.)
Sundried
250
Aggregates
(Cum)
40
20
Shingle or Aggregate
(Cum)
0.20
0.20
Surkhi
(cum)
--
--
--
--
0.13
--
--
--
0.15
Surkhi
(cum)
--
--
--
WATER SUPPLY
Note :- 1. The rates for stringingout cast iron,A.C., P.V.C. and H.D.P.E. pipes and their specials etc. provided
under this chapter which are in the wider sense labour rates in case of which the material is generally
issued to the contractors free of cost from the stores of the Engineer-in-charge or the nearest railway
station, include the carriage of material within a radius of 5km. of the site of works.
1 2 3 4 5
28.1 Excavation for pipe lines in
trenches and pits, including
trimming and dressing sides,
levelling of beds of trenches to
correct grade, cutting joint holes,
refilling, consolidation and
watering of refill in 15 cm Layers
and restoration of unmettaled or
unpaved surface to its original
condition including the cost of
necessary shoring, timbering,
dewatering of rainwater, diversion
for traffic, night singlals, fixing
caution boards, crossing over
trenches for access to the houses,
watching, fencing, etc., and
removal of surplus spoil out
side/inside the town involving
lead upto 1.00km.
1 2 3 4 5
(ii) For ordinary gravel-soil
involving pick work. 100 cum 1901.00 1912.00
1 2 3 4 5
(i) All classes of soil except
rocky. 100cum 1706.00 1716.00
1 2 3 4 5
28.3 Excavation for Pipe lines in
trenches and pits, in open areas
where disposal of surplus earth
is done along the alignment,
including trimming and dressing
sides, levelling of beds of trenches
to correct grades, cutting joint
holes, refilling, consolidation and
dewatering of refill in 15cm layers
and restoration of unmetalled or
unpaved surface to its original
condition. The rate includes the
Cost of necessary timbering,
dewatering of rainwater, diversion
for traffic, night signals, fixing
caution boards, watching fencing,
etc.,
1 2 3 4 5
(ii) For ordinary gravel-soil
involving pick work. 100cum 1822.00 1833.00
1 2 3 4 5
28.4 Excavation for Pipe Lines in
trenches and pits upto 1.5m
Depth in open area where
disposal of surplus earth is done
alongwith alignment, including
trimming and drsessing sides,
levelling of beds of trenches to
correct grade, cutting joint holes,
refilling; consolidation and
watering of refill in 15cm layers
and Restoration of unmetalled
or unpaved surface to its
original condition excluding
cost of shoring and timbering
but including the cost of
dewatering of rain water, diversion
for traffic, night signals, fixing
caution boards, watching, fencing
etc.
Note :-
(i) The contractor must fix sign boards to
indicate the execution of works and
diversion of traffic, etc. The sign boards
will be supplied by the Govt. Department
from their stores but the fixing and
maintenance at site will be done by the
contractor and the rates include the cost
of the same.
1 2 3 4 5
(ii) The maximum width of trenches for
measurement purposes shall be as
given in P.W.D. specification book and
taken as shown on the diagrams given
below. If the actual width of the trenches
is less than shown on the diagrams
below, the actual volume of excavation
only shall be measured and paid for. If
the actual width of trenches is greater
than shown on the diagrams below, the
width to be measured for calculation of
volume of excavation to be paid for shall
be in accordance with the diagrams
given below :-
1 2 3 4 5
(v) No extra shall be payable in
respect of item No.28.1 to
28.4 inclusive for any
seepage of water during
excavation above spring
level.
Notes :-
The extra quantity and lead for
disposal of surplus earth beyond
one km will only be payable on
written orders certificate of the
officer not below the rank of Sub
Divisional Engineer.
1 2 3 4 5
28.7 Extra for cutting through
metalled Roads and their
foundation including sorting
screening and stacking the
soling stone and road metal at the
site of work as ordered by the
Engineer-in-charge.
10 sqm. 23.50 26.50
1 2 3 4 5
(iii) All other demolition work in
connection with pipe lines
shall be paid for at the rates
laid down for demolition of
various classes of work under
relative chapters.
1 2 3 4 5
(l) 600mm internal diameter pipe
line laid complete. 10 m 190.00 198.00
1 2 3 4 5
(a) 80mm internal diameter pipe Per metre
line laid complete. of pipeline
laid,
complete. 6.70 7.10
1 2 3 4 5
(k) 500mm internal diameter pipe Per metre
line laid complete. of pipeline
laid,
complete. 67.00 71.00
1 2 3 4 5
(b) 63.5 mm Outside dia pipe
Wall Th. 1.6 mm Per Joint 10.20 10.20
1 2 3 4 5
28.12 Stringing out P.V.C. Pipes and
specials casting along the
Trenches and laying the same in
Trenches to correct alignment
and gradients, Including cartage
from Divisional stores or
nearest Railway Station to site
of works and return of pieces of
pipes to stores :---
1 2 3 4 5
(a) 80mm internal diameter pipe
line. Per cut 3.30 3.60
1 2 3 4 5
(d) 101.6 mm Outside dia pipe
Wall Th. 1.6 mm Per Cut 7.35 7.35
1 2 3 4 5
(d) 110mm outer diametre pipe
line. Per cut 1.35 1.50
1 2 3 4 5 6 7
1 2 3 4 5
1 2 3 4 5
(l) 600mm internal diametre of
pipe, valves or specials. Each 68.50 73.50
1 2 3 4 5
(g) 300mm internal diametre of
pipe, valves or specials. Per joint 8.50 9.30
1 2 3 4 5
(e) 250mm internal diametre Per joint 10.70 11.70
1 2 3 4 5
(a) 80mm internal diametre of
valves Each 14.10 15.40
1 2 3 4 5
28.26 Extra for fixing Single air Valves
all sizes including Cartage from
Divisional Stores or nearest
Railway Station to Site of Works,
drilling tappling and screwing in
valve connection.
Each 53.50 57.00
1 2 3 4 5
(j) 450mm internal diametre of
flap valve Each 55.00 59.00
1 2 3 4 5
Size of Ferrule:
1 2 3 4 5
Notes :- Ferrule will be supplied without
charge to the contractor, ex-
Divisional store or from nearest
Railway Station. The fixing rate
includes cartage to site of work
and also the cost of excavation up
to the main and filling in and
making good the surface after
finishing the job. The rate is for
complete job.
1 2 3 4 5
(v) 40mm internal diameter of
pipe line. Metre 16.80 18.40
1 2 3 4 5
28.36 Labour for laying, jointing,
fixing and testing G.I. Pipe Lines
and Specials tees, bends,
sockets elbow etc. In trenches in
the ground, cutting, threading and
testing etc., complete.
1 2 3 4 5
(a) 20mm outer diameter Metre 1.20 1.35
1 2 3 4 5
Notes :-
1 2 3 4 5
(ii) All G.I/H.D.P.E./P.V.C./W.I.
pipes and specials shall be
obtained by indent upon the
Executive Engineer, Public
Health concerned, and direct
purchases by the contractor
shall not be permitted except
in such special cases as shall
be allowed in writing by the
Executive Engineer.
1 2 3 4 5
(d) 32mm internal diameter Each 3.20 3.45
Notes :-
1 2 3 4 5
Notes :-
1 2 3 4 5
Notes :-
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
Notes :-
1 2 3 4 5
28.52 Fixing bell mouths with or
without Puddle Collars Puddle
collar Pieces and Plain,
Socketted or flanged Pipes in
brick works, cement concrete or
reinforced Cement Concrete
used for inlets, outlets, scour and
overflow pipes of the overhead
service reservoirs of the length of
pipe of special embedded to
Correct alignment and Levels
including the cost of cutting
hole if required, cement concrete
filling around the pipes or specials
and making good the joint water
tight including repointing,
replastering and colour or white-
washing as prequired by the
Engineer-in-charge.
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
28.57 Providing and placing in
horizontal layers filtering media
screened, washed and cleaned
as described below :-
1 2 3 4 5
28.58 Painting G.I.Pipes and Specials
with Superior and Ordinary
Quality Synthetic enamels Paint
in all shades as per I.S.I.
specification on existing or new
work, two coats paints including
cleaning rubbing surface, etc.
1 2 3 4 5
Labour With special With I.S.I. Labour With With
rate quality paint marked rate special I.S.I.
quality quality marked
paint paint quality
paint
1 2 3 4 5
Notes :- The special quality Paints for
item No's 28.58 to 28.61 are
those paints which are
approved/declared as such
by the Chief Engineer
incharge.
1 2 3 4 5
28.64 Cutting holes upto 23cm square
for pipes in flooring and roofs of
bricks, tiles with lime concrete
and making good including
repointing, replastering and colour
or white washing where required.
1 2 3 4 5
28.66 Dismantling lead Caulked Joints
of cast iron Socketted Pipes,
Valves and Specials by heating
the Joints including the cast of
Labour, Fuel and tools, etc.,
collecting the lead taken out from
the joints and delivering the same
to the Divisional stores.
1 2 3 4 5
1 2 3 4 5
(f) 550mm and 600mm internal
diameter of pipe, valves or
special. Per Joints 11.25 12.15
1 2 3 4 5
(k) 300mm internal diameter of
pipe. 10 metre of
pipe line
dismanteled 22.50 24.00
Notes :-
1 2 3 4 5
(ii) All measurements shall be
taken along the centre line of
axis of the pipe line
throughout its length and
shall include the overall
laying length of sluice valves
and specials fixed therein.
1 2 3 4 5
1 2 3 4 5
(a) 15mm internal diameter pipe
line. Metre 1.15 1.25
(a) For sewer below : 760 mm i/d Per Metre 48.00 48.00
Notes :-
Notes :-
(i) The disposal of all rubbish off site of
work means the removal thereof to the
place of disposal outside the town into
pounds, and depression or other
suitable places, levelling off the same
and cleaning of the site of structures
dismentled, to the satisfaction of the
Engineer-in-charge.
Notes :-
Note :-
Notes :-
The finished inside dimension of egg- Per metre of Rs. Rs. Rs.
shaped sewer being :- completed
sewer
(a) 610mm x 915mm Per metre of
completed
sewer 526.00 492.00 537.00
Rates
The finished inside diameter of sewer With lime With cement With lime
Concrete concrete Concrete
being :-
Notes :-
Notes :-
Notes :
(i) The octroi and terminal taxes on the
pipes and specials will not be payable
by the contractor, but he should be
liable for all losses, breakages and
other damages to the pipes and
specials from the moment he takes
delivery thereof and thereafter until
the pipes and specials have been
jointed and tested.
Notes :-
Notes :-
Construction of rectangular
standard brick masnory manhole
chambers to standard drawings on
new egg shaped sewers upto the
required depth in 1:5 cement sand
mortar, lime concrete 40 percent
lime mortar with 20mm gauge brick
ballast in haunches above the
archring where the depth of cover
in traffic streets is less than 1:5
metre, 12.50mm thick water tight
1:2 cement sand plaster with a
floating coat of neat cement and
finished with two coats of sodium
silicate on interior surface, where
required, reinforced cement
concrete slab 180mm. thick fixing
560mm. internal diameter C.I.
manhole frame and cover weight
not less than 2.5 quintal painted
with three coats of black bitumen
paint, fixing galvanised malleable
iron steps embedded in 1:2 cement
sand mortar etc. complete.
Rates
Sub-mountainous Region
Through Rate
With cement
conc. 1:8:16
with brick
ballast
Rs.
503.00
531.00
561.00
593.00
626.00
666.00
696.00
724.00
759.00
792.00
825.00
867.00
With
Cement
Concrete
Rs.
280.00
303.00
320.00
338.00
355.00
380.00
397.00
415.00
435.00
457.00
475.00
495.00
With cement
concrete
Rs.
468.00
508.00
547.00
602.00
643.00
700.00
748.00
787.00
904.00
945.00
988.00
Rates
Sub-mountainous Region
Rs.
With cement
concrete
Rs.
232.00
253.00
280.00
309.00
326.00
369.00
396.00
418.00
440.00
457.00
482.00
227.00
248.00
275.00
303.00
319.00
361.00
387.00
409.00
430.00
447.00
471.00
Rs.
Rs.
SANITARY INSTALLATIONS
Notes :-
(i) All the labour rates provided under this chapter includes the carriage of material within a radius of
5km of the site of work.
(ii) The labour as well as through rates provided under this chapter include the wastage and breakage
of various material during construction
(iii) Provision has been made under this chapter for sanitary fittings of best indian make to the approval
of the Engineer-in-charge. In this connection the Superintending Engineer will circulate from time to
time the list of fittings of best Indian manufacture which may be considered to be on the approved
list and be allowed to be used on works
(iv) Separate rates have been provided for different type of fittings, pipes and specials for different
sizes.
Sr. No. Description Unit Rates
Plains Area Sub-Mountainous Region
Each 164.50
Each 291.00
B - URINALS
(ii) Large size 835mm x 355mm white Each 20.00 283.00 21.50
(i) Size 450 mm x 300 mm with one tap Each 146.00 432.00 160.00
(ii) Size 550 mm x 400 mm with one tap Each 146.00 495.00 160.00
(iii) Size 630 mm x 450 mm with one tap Each 146.00 576.00 160.00
(i) Size 510mm x 400mm with one tap Each 146.00 521.50 160.00
(ii) Size 530mm x 430mm with one tap Each 146.00 614.00 160.00
(iii) Size 610mm x 510mm with one tap Each 146.00 761.00 160.00
(iv) Size 630mm x 450mm with one tap Each 146.00 612.50 160.00
(v) Size 630mm x 510mm with one tap Each 146.00 824.00 160.00
(vi) Size 690mm x 550mm with one tap Each 146.00 1001.00 160.00
(D) Sinks
(a) With bottle trap (Indian make) Each 9.00 107.50 10.00
(b) With 'P' or 'S' Trap (Indian make) Each 6.00 84.25 6.50
(a) Vitreous china ware white fountain. Each 117.00 1,124.50 128.50
(b) C.P Brass with revolving joint showers. Each 2.00 77.90 2.20
(a) C.P. Brass toilet paper holder. Each 8.00 46.00 9.00
(i) stop cock male & female end Each 3.00 91.60 3.30
(ii) Concealed stop cock with flange. Each 3.00 104.20 3.30
(i) stop cock male & female end Each 4.25 112.00 4.50
(a) Aluminium
(b) C.P.Brass
(a) 100mm internal diameter (1.36 kg) Each 8.10 37.75 8.90
(b) 75mm internal diameter (1.13 kg) Each 6.50 31.60 7.15
(c) 50mm internal diameter (0.91 kg) Each 5.50 25.25 6.00
(a) For 100mm internal diameter pipes Each 6.75 17.40 7.40
(b) For 75mm internal diameter pipes Each 6.75 14.95 7.40
(c) For 50mm internal diameter pipes Each 6.75 13.70 7.40
(a) 50 mm i/d outlet plain Nahani trap Each 34.50 114.75 38.00
(b) 75 mm i/d outlet plain Nahani trap Each 34.50 119.50 38.00
(xx) P' or 'S' trap with vent Each 3.45 77.40 3.75
(xxi) P' or 'S' trap without vent Each 3.45 71.20 3.75
(xxi) 'P' or 'S' trap with vent Each 3.45 71.20 3.75
(xxii) 'P' or 'S' trap without vent Each 3.45 65.05 3.75
(vii) Single invert junction with door Each 3.45 84.75 3.75
(viii) Double invert junction with door Each 3.45 99.50 3.75
(xvi) 'P' or 'S' trap without vent Each 3.45 58.90 3.75
(xvii) 'P' or 'S' trap with vent Each 3.45 65.05 3.75
DRAINAGE
Rates
Sub-Mountainous Region
Through Rate
Through Rate
808.00
821.50
990.50
1021.00
Through Rate
1161.50
1193.00
920.00
940.00
Through Rate
1640.00
1665.00
1786.00
1761.00
164.50
291.00
Through Rate
250.50
105.00
18.00
13.00
25.00
70.00
85.00
101.00
20.00
Through Rate
504.00
741.00
1032.00
Through Rate
1469.00
109.75
108.50
Through Rate
1,106.00
1945.00
2837.50
3878.00
Through Rate
1,975.00
3,673.00
5,430.00
7,326.00
Through Rate
623.00
926.50
1275.00
Through Rate
1806.00
70.00
43.00
54.00
149.00
226.00
348.00
435.00
193.00
197.00
284.50
Through Rate
446.00
509.00
590.00
904.00
535.50
628.00
775.00
626.50
838.00
1015.00
Through Rate
101.00
235.00
593.50
32.00
99.50
105.00
67.00
93.00
Through Rate
334.00
347.00
366.00
385.00
853.00
920.00
920.00
1012.00
2736.00
2103.00
267.50
Through Rate
236.00
252.75
265.50
1077.00
5,297.00
4,474.75
Through Rate
397.00
419.00
537.00
837.00
870.00
116.00
56.00
108.50
84.75
1,136.00
1,127.00
Through Rate
1,295.00
46.50
35.10
26.25
78.10
133.20
47.00
41.00
55.50
130.00
124.50
126.00
Through Rate
7
121.000
67.000
109.00
71.00
66.50
62.75
43.25
75.25
43.25
28.00
31.50
48.75
48.75
97.00
Through Rate
124.00
111.50
54.75
75.50
96.50
117.25
25.60
30.00
9.80
12.35
Through Rate
103.00
120.00
106.10
90.85
91.90
104.50
112.25
123.50
72.25
117.80
189.90
250.60
Through Rate
41.750
30.40
30.40
27.85
605.75
483.00
22.75
26.50
30.25
35.35
41.75
48.00
107.50
Through Rate
85.40
75.50
62.30
304.00
261.00
60.40
10.40
Through Rate
38.55
32.25
25.75
18.05
15.60
14.35
132.00
136.75
Through Rate
118.25
123.00
48.10
129.40
42.60
80.75
123.30
74.00
80.75
129.40
74.00
Through Rate
123.30
131.30
114.65
53.60
43.20
46.90
45.70
59.80
70.30
35.20
77.70
71.50
27.20
71.50
72.75
74.00
75.20
77.70
81.40
17.65
24.40
32.45
36.15
Through Rate
41.65
45.35
51.50
63.85
41.95
37.00
109.70
64.70
102.30
58.00
64.70
109.70
58.00
102.30
96.15
110.95
43.15
36.40
41.95
54.25
Through Rate
40.80
21.60
65.35
28.40
71.50
65.35
48.10
50.60
53.00
55.50
59.20
62.90
35.80
30.25
97.35
48.10
90.00
41.95
85.05
99.80
37.00
30.85
Through Rate
35.80
17.90
34.60
59.20
44.40
59.20
65.35
32.10
33.30
34.55
35.80
38.25
40.70
239.40
178.90
124.95
96.00
74.80
163.00
Through Rate
128.85
94.50
73.20
19.00
27.50
8.40
120.90
96.45
70.20
51.00
41.25
35.25
8.00
13.40
6.75
Through Rate
21.90
1.10
0.80
0.60
Through Rate
7
0.90
0.65
0.50
2.00
1.45
1.10
1.60
1.15
0.90
1.15
0.85
0.65
2.25
1.60
1.20
Through Rate
1.80
1.35
1.00
3.75
2.70
2.05
66.85
85.80
117.45
174.40
256.60
383.10
47.85
Through Rate
7
66.85
92.15
123.80
161.70
231.30
Through Rate
Through Rate
181.00
226.00
203.00
265.00
126.85
39.10
Through Rate
1799.00
1977.50
2242.50
112.50
1 2 3
31.01 A&B Deleted
31.01 C P.V.C. CASING AND CAPPING WIRING SYSTEM:
Wiring in P.V.C. insulated copper conductor ISI marked cable
(Unsheathed) left bare in P.V.C. casing and capping including
all the P.V.C. accessories as required and Semi–recessed
Teak-wood boxes, covered with Brown-bakelite/ White-glazed
Translucent back side painted sheet cover 3mm thick to have
the control switches, wall-sockets and fan regulators etc.:-
1 2
Wiring in P.V.C. insulated copper conductor ISI marked 3
(Unsheathed) cable left bare in welded conduit pipe (1.6mm
thick) recessed in wall etc., complete with M.S. sheet box
(Sheet thickness 1.6mm) and of required design, size i.e. 10cm
x 10cm, 22.5cm x 10cm, 20cm x 25cm, fan box 18cm x 10cm
having weight 0.450kg minimum, 0.800kg minimum, 1.350kg
minimum and fan box 0.950kg minimum (Weight without M.S.
Sheet cover) respectively each 60mm deep except fan box
having depth 10cm covered with 1.6mm thick M.S. sheet fixed
with screws, machine fabricated, spot welded,with knock-outs
corner pieces (3mm thick M.S. sheet duly threaded hole
suitable to fix the box cover sheet) welded 3mm deep from the
edge of the box, all boxes duly primer coated allaround and
provided with an earth stud for having fan regulators, wall-
sockets and switches etc.,and covered
1 2 3
I. Wiring fan point in 1.5mm² copper conductor cable. Each
II. Wiring light point in 1.5mm² copper
conductor cable. Each
III. Wiring call-bell point in 1.5mm² copper conductor cable.
Each
IV. Wiring 3-pin 5Amp. wall-socket point in 1.5mm² copper
conductor cable including bonding to existing earth with
1mm² PVC insulated multistrand (FR) unsheathed
copper wire. Each
V. Wiring 3-pin 5Amp. plug control comprising wall-socket,
kit-kat fuse unit and switch including bonding to existing
earth with 1mm² PVC insulated multistrand (FR)
unsheathed copper wire. Each
VI. Wiring 3-pin 15Amp. plug control comprising wall-socket,
kit-kat fuse unit and switch including bonding to earth
with 4mm² G.I. stranded wire. Each
31.04B VII. Wiring light point in 1.5mm² copper conductor cable
without control switch. Each
VIII. Wiring light point in 1.5mm² copper conductor cable with
double control switches. Each
IX. Wiring in 1.5mm² copper conductor cable for bed control
switch upto ceiling-rose but without bed-switch and
flexible wire. Each
31.05 DISMANTLING WIRING POINTS:
Dismantling old wiring points (not recessed) including
necessary repairs to wall etc.:
I. Light, fan or call-bell point. Each
II. Wall socket point. Each
31.06 A Deleted
31.06 B MAINS & SUB-MAINS IN P.V.C CASING
& CAPPING:
Wiring of mains & sub-mains in two single core P.V.C.
insulated with copper conductor ISI marked cables
(Unsheathed) left bare overall 1100volts grade in P.V.C. casing
& capping including painting etc., as required:-
I. Cable size 1.5mm² copper conductor. Metre
II. Cable size 2.5mm² copper conductor. Metre
III. Cable size 4mm² copper conductor. Metre
IV. Cable size 6mm² copper conductor. Metre
V. Cable size 10mm² copper conductor. Metre
VI. Cable size 16mm² copper conductor. Metre
VII. Cable size 25mm² (7/ 2.24mm). Metre
VIII. Supply & erection of P.V.C. casing and capping as
required. Metre
31.07 A&B Deleted
31.08 A Deleted
31.08 B P.V.C INSULATED (Unsheathed) COPPER
CONDUCTOR CABLES:
Supply & erection of P.V.C. insulated single core cable with ISI
marked copperconductor (Unsheathed) left bare in pipe or
casing of suitable size excluding the cost of supply & erection
of pipe or casing:-
1 2 3
I. Cable Size 1.5mm² copper conductor 1100 volts grade. Metre
II. Cable Size 2.5mm² copper conductor 1100 volts grade. Metre
III. Cable Size 4mm² copper conductor 1100 volts grade. Metre
IV. Cable Size 6mm² copper conductor 1100 volts grade. Metre
V. Cable Size 10mm² copper conductor 1100 volts grade. Metre
VI. Cable Size 16mm² copper conductor 1100 volts grade. Metre
31.09 A Deleted
31.09 B PVC INSULATED POLYTHENE SHEATHED AND PVC
INSULATED PVC SHEATHED CABLES.
Supply and erection of PVC insulated polythene
sheathed and PVC insulated PVC sheathed copper
conducter ISI marked single core cable in pipe etc.
of suitable size excluding the cost & erection of pipe
etc.
1 2 3
VII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 35mm². Metre
VIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 50mm². Metre
IX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 2.5mm². Metre
X. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 4mm². Metre
XI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 6mm². Metre
XII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 10mm². Metre
31.10 (A) XIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core)16mm². Metre
XIV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 25mm². Metre
XV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 35mm². Metre
XVI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 50mm². Metre
XVII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 70mm². Metre
XVIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 95mm². Metre
XIX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 120mm². Metre
XX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 150mm². Metre
XXI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 185mm². Metre
XXII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 225mm². Metre
XXIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 240mm². Metre
XXIV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 300mm². Metre
1 2 3
XXV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 400mm². Metre
XXVI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½ core) 25mm². Metre
XXVII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½ core) 35mm². Metre
XXVIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½ core) 50mm². Metre
XXIX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade (3½
core) 70mm². Metre
XXX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½ core) 95mm². Metre
31.10 (A) XXXI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½ core) 120mm². Metre
XXXII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade (3½
core) 150mm². Metre
XXXIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 185mm². Metre
XXXIV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 225mm². Metre
XXXV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 240mm². Metre
XXXVI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 300mm². Metre
XXXVII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 400mm². Metre
XXXVIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 2.5mm². Metre
XXXIX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 4mm². Metre
XL. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 6mm². Metre
XLI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 10mm². Metre
XLII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 16mm². Metre
1 2 3
31.10 B P.V.C. INSULATED ARMOURED CABLES (LOOSE-IN
THE EXISTING TRENCH OR PIPE):
Supply & laying of aluminium conductor P.V.C. insulated
armoured and served cable to be laid loose in the existing
trench or pipe:-
I. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 2.5mm². Metre
II. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 4mm². Metre
III. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 6mm². Metre
IV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 10mm². Metre
31.10 (B) V. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 16mm². Metre
VI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 25mm². Metre
VII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 35mm². Metre
VIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(twin core) 50mm². Metre
IX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 2.5mm². Metre
X. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 4mm². Metre
XI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 6mm². Metre
XII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 10mm². Metre
XIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core)16mm². Metre
XIV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 25mm². Metre
XV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 35mm². Metre
XVI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 50mm². Metre
1 2 3
XVII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 70mm². Metre
XVIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 95mm². Metre
XIX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 120mm². Metre
XX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 150mm². Metre
XXI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 185mm². Metre
XXII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 225mm². Metre
31.10 (B) XXIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 240mm². Metre
XXIV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 300mm². Metre
XXV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3core) 400mm². Metre
XXVI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 25mm². Metre
XXVII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 35mm². Metre
XXVIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 50mm². Metre
XXIX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 70mm². Metre
XXX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 95mm². Metre
XXXI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 120mm². Metre
XXXII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 150mm². Metre
XXXIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 185mm². Metre
XXXIV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 225mm². Metre
1 2 3
XXXV. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 240mm². Metre
XXXVI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 300mm². Metre
XXXVII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(3½core) 400mm². Metre
XXXVIII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 2.5mm². Metre
XXXIX. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 4mm². Metre
XL. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 6mm². Metre
31.10 (B) XLI. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 10mm². Metre
XLII. Aluminium conductor P.V.C. insulated armoured and
served cable working voltage 1100volts grade
(4core) 16mm². Metre
31.10 C P.V.C. INSULATED UN-ARMOURED CABLES (ON
SURFACE):
Supply and laying of P.V.C. insulated P.V.C. sheathed
aluminium conductor un-armoured cable working voltage upto
and including 1100volts grade (on surface) as required:-
1 2 3
IX. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 2.5mm². Metre
X. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 4mm². Metre
XI. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 6mm². Metre
XII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 10mm². Metre
XIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 16mm². Metre
XIV. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 25mm². Metre
31.10C XV. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 35mm². Metre
XVI. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 50mm². Metre
XVII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 70mm². Metre
XVIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 95mm². Metre
XIX. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 120mm². Metre
XX. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 150mm². Metre
XXI. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 185mm². Metre
XXII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 225mm². Metre
XXIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 240mm². Metre
XXIV. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 300mm². Metre
XXV. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3core) cable of
size 400mm². Metre
XXVI. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 25mm². Metre
1 2 3
XXVII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 35mm². Metre
XXVIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 50mm². Metre
XXIX. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 70mm². Metre
XXX. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 95mm². Metre
XXXI. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 120mm². Metre
XXXII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 150mm². Metre
31.10C XXXIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 185mm². Metre
XXXIV. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 225mm². Metre
XXXV. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 240mm². Metre
XXXVI. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 300mm². Metre
XXXVII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (3½core) cable of
size 400mm². Metre
XXXVIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (4core) cable of
size 2.5mm². Metre
XXXIX. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (4core) cable of
size 4mm². Metre
XL. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (4core) cable of
size 6mm². Metre
XLI. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (4core) cable of
size 10mm². Metre
XLII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (4core) cable of
size 16mm². Metre
XLIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (4core) cable of
size 25mm². Metre
XLIV. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (4core) cable of
size 35mm². Metre
1 2 3
XLV. P.V.C. insulated P.V.C. sheathed aluminium
conductor un-armoured (4core) cable of
size 50mm². Metre
31.10 D P.V.C. INSULATED UN-ARMOURED CABLE (LOOSE-
IN THE EXISTING TRENCH OR PIPE):
31.10D Supply and laying of aluminium conductor P.V.C. insulated
P.V.C. sheathed un-armoured cable to be laid loose-in the
existing trench or pipe:
I. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(twin core) 2.5mm². Metre
II. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(twin core) 4mm². Metre
III. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(twin core) 6mm². Metre
31.10D IV. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(twin core) 10mm². Metre
V. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(twin core) 16mm². Metre
VI. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(twin core) 25mm². Metre
VII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(twin core) 35mm². Metre
VIII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(twin core) 50mm². Metre
IX. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 2.5mm². Metre
X. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 4mm². Metre
XI. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 6mm². Metre
XII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 10mm². Metre
XIII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 16mm². Metre
XIV. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 25mm². Metre
XV. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 35mm². Metre
1 2 3
XVI. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 50mm². Metre
XVII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 70mm². Metre
XVIII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 95mm². Metre
XIX. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 120mm². Metre
XX. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 150mm². Metre
XXI. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 185mm². Metre
31.10D XXII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 225mm². Metre
XXIII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 240mm². Metre
XXIV. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 300mm². Metre
XXV. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3core) 400mm². Metre
XXVI. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 25mm². Metre
XXVII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 35mm². Metre
XXVIII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 50mm². Metre
XXIX. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 70mm². Metre
XXX. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 95mm². Metre
XXXI. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 120mm². Metre
XXXII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 150mm². Metre
XXXIII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 185mm². Metre
1 2 3
XXXIV. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 225mm². Metre
XXXV. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 240mm². Metre
XXXVI. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 300mm². Metre
XXXVII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(3½core) 400mm². Metre
XXXVIII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(4core) 2.5mm². Metre
XXXIX. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(4core) 4mm². Metre
31.10D XL. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(4core) 6mm². Metre
XLI. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(4core) 10mm². Metre
XLII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(4core) 16mm². Metre
XLIII. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(4core) 25mm². Metre
XLIV. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(4core) 35mm². Metre
XLV. Aluminium conductor P.V.C. insulated P.V.C. sheathed
un-armoured cable working voltage 1100volts grade
(4core) 50mm². Metre
31.10 E P.V.C INSULATED ARMOURED CABLE (ON
SURFACE):
Supply and laying of P.V.C. insulated P.V.C. sheathed
aluminium conductor armoured cable working voltage upto
and including 1100volts grade (on surface) as required:-
I. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 2.5mm². Metre
II. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 4mm². Metre
III. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 6mm². Metre
IV. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 10mm². Metre
1 2 3
V. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 16mm². Metre
VI. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 25mm². Metre
VII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 35mm². Metre
VIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 50mm². Metre
IX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 2.5mm². Metre
X. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 4mm². Metre
XI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 6mm². Metre
XII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 10mm². Metre
31.10E XIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 16mm². Metre
XIV. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 25mm². Metre
XV. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 35mm². Metre
XVI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 50mm². Metre
XVII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 70mm². Metre
XVIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 95mm². Metre
XIX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 120mm². Metre
XX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 150mm². Metre
XXI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 185mm². Metre
XXII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 225mm². Metre
XXIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 240mm². Metre
XXIV. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 300mm². Metre
XXV. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 400mm². Metre
XXVI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 25mm². Metre
XXVII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 35mm². Metre
XXVIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 50mm². Metre
1 2 3
XXIX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 70mm². Metre
XXX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 95mm². Metre
XXXI. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 120mm². Metre
XXXII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 150mm². Metre
XXXIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 185mm². Metre
XXXIV. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 225mm². Metre
XXXV. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 240mm². Metre
XXXVI. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 300mm². Metre
31.10E XXXVII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 400mm². Metre
XXXVIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 2.5mm². Metre
XXXIX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 4mm². Metre
XL. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 6mm². Metre
XLI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 10mm². Metre
XLII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 16mm². Metre
31.10 F P.V.C INSULATED ARMOURED CABLE (FLUSHED):
1 2 3
V. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 16mm². Metre
VI. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 25mm². Metre
VII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 35mm². Metre
VIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 50mm². Metre
IX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 2.5mm². Metre
X. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 4mm². Metre
XI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 6mm². Metre
XII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 10mm². Metre
XIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 16mm². Metre
XIV. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 25mm². Metre
31.10F XV. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 35mm². Metre
XVI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 50mm². Metre
XVII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 70mm². Metre
XVIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 95mm². Metre
XIX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 120mm². Metre
XX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 150mm². Metre
XXI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 185mm². Metre
XXII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 225mm². Metre
XXIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 240mm². Metre
XXIV. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 300mm². Metre
XXV. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3core) cable of size 400mm². Metre
XXVI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 25mm². Metre
XXVII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 35mm². Metre
XXVIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 50mm². Metre
1 2 3
XXIX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 70mm². Metre
XXX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (3½core) cable of size 95mm². Metre
XXXI. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 120mm². Metre
XXXII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 150mm². Metre
XXXIII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 185mm². Metre
XXXIV. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 225mm². Metre
XXXV. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 240mm². Metre
XXXVI. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 300mm². Metre
XXXVII. P.V.C. insulated P.V.C. sheathed aluminium
conductor armoured (Twin core) cable of
size 400mm². Metre
31.10F XXXVIII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 2.5mm². Metre
XXXIX. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 4mm². Metre
XL. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 6mm². Metre
XLI. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 10mm². Metre
XLII. P.V.C. insulated P.V.C. sheathed aluminium conductor
armoured (4core) cable of size 16mm². Metre
31.11 PIPES & FLEXIBLE PIPES:
Supply & erection of pipe for wiring purposes including bends,
inspection boxes etc., where necessary including painting as
required:-
I. Galvanised iron pipe 15mm dia. (On surface). Metre
II. Galvanised iron pipe 20mm dia. (On surface). Metre
III. Galvanised iron pipe 25mm dia. (On surface). Metre
IV. Galvanised iron pipe 32mm dia. (On surface). Metre
V. Galvanised iron pipe 40mm dia. (On surface). Metre
VI. Galvanised iron pipe 50mm dia. (On surface). Metre
VII. Galvanised iron pipe 15mm dia. (Flushed). Metre
VIII. Galvanised iron pipe 20mm dia. (Flushed). Metre
IX. Galvanised iron pipe 25mm dia. (Flushed). Metre
X. Galvanised iron pipe 32mm dia. (Flushed). Metre
XI. Galvanised iron pipe 40mm dia. (Flushed). Metre
XII. Galvanised iron pipe 50mm dia. (Flushed). Metre
1 2 3
XIII. Heavy gauge welded conduit pipe (1.60mm thick) 20mm
dia. (on surface). Metre
XIV. Heavy gauge welded conduit pipe (1.60mm thick) 25mm
dia. (on surface). Metre
XV. Heavy gauge welded conduit pipe (1.60mm thick) 32mm
dia. (on surface). Metre
XVI. Heavy gauge welded conduit pipe (2.00mm thick) 40mm
dia. (on surface). Metre
XVII. Heavy gauge welded conduit pipe (2.00mm thick) 50mm
dia. (on surface). Metre
XVIII. Heavy gauge welded conduit pipe (1.60mm thick) 20mm
dia. (flushed). Metre
XIX. Heavy gauge welded conduit pipe (1.60mm thick) 25mm
dia. (flushed). Metre
XX. Heavy gauge welded conduit pipe (1.60mm thick) 32mm
dia. (flushed). Metre
XXI. Heavy gauge welded conduit pipe (2.00mm thick) 40mm
dia. (flushed). Metre
XXII. Heavy gauge welded conduit pipe (2.00mm thick) 50mm
dia. (flushed). Metre
XXIII. Galvanised iron flexible pipe complete with sockets,
nipples & check-nuts etc., at both ends (upto
1metre):-
a. Size 15mm dia. Metre
b. Size 20mm dia. Metre
c. Size 25mm dia. Metre
d. Size 32mm dia. Metre
31.11 e. Size 40mm dia. Metre
f. Size 50mm dia. Metre
g. Supply and erection of galvanised iron flexible pipe
15mm dia. (As additional length). Metre
h. Supply and erection of galvanised iron flexible pipe
20mm dia. (As additional length). Metre
i. Supply and erection of galvanised iron flexible pipe
25mm dia. (As additional length). Metre
j. Supply and erection of galvanised iron flexible pipe
32mm dia. (As additional length). Metre
k. Supply and erection of galvanised iron flexible pipe
40mm dia. (As additional length). Metre
l. Supply and erection of galvanised iron flexible pipe
50mm dia. (As additional length). Metre
XXIV. Supply and Erection of flexible/pliable non-metallic
conduit complete with compression glands, having
locking arrangement, check-nuts as required upto
½metre length:-
a. Size 20mm dia. Metre
b. Size 25mm dia. Metre
c. Size 40mm dia. Metre
XXV. Supply and erection of flexible/ pliable non-metallic
conduit without compression glands and check nuts
(As additional length beyond ½metre):-
1 2 3
a. Size 20mm dia. Metre
b. Size 25mm dia. Metre
c. Size 40mm dia. Metre
1 2 3
XXII. Sheet metal/ iron clad triple pole switch with neutral -link
100Amp. 415volts. Each
XXIII. Sheet metal/ iron clad triple pole switch with neutral -link
200Amp. 415volts. Each
XXIV. Sheet metal/ iron clad triple pole switch with neutral -link
320Amp. 415volts. Each
XXV. Sheet metal/ iron clad triple pole switch with neutral -link
400Amp. 415volts. Each
31.13 SHEET METAL/ IRON CLAD CHANGE-OVER SWITCH :
Supply and erection of sheet metal/ iron clad change–over
switch on existing surface with G.I. bolts & nuts/rag bolts and
nuts etc., according to the size of holes in the body of the
switch including bonding to the existing earth :-
I. Sheet metal/ iron clad double pole change-over switch
16Amp. 415volts. Each
II. Sheet metal/ iron clad double pole change-over switch
32Amp. 415volts. Each
III. Sheet metal/ iron clad double pole change-over switch
63Amp. 415volts. Each
IV. Sheet metal/ iron clad double pole change-over switch
100Amp. 415volts. Each
V. Sheet metal/ iron clad double pole change-over switch
200Amp. 415volts. Each
VI. Sheet metal/ iron clad triple pole change-over switch
16Amp. 415volts. Each
VII. Sheet metal/ iron clad triple pole change-over switch
32Amp. 415volts. Each
VIII. Sheet metal/ iron clad triple pole change-over switch
63Amp. 415volts. Each
31.13 IX. Sheet metal/ iron clad triple pole change-over switch
100Amp. 415volts. Each
X. Sheet metal/ iron clad triple pole change-over switch
200Amp. 415volts. Each
XI. Sheet metal/ iron clad triple pole change-over switch
320Amp. 415volts. Each
XII. Sheet metal/ iron clad triple pole change-over switch
400Amp. 415volts. Each
XIII. Sheet metal/ iron clad triple pole change-over switch
500Amp. 415volts. Each
XIV. Sheet metal/ iron clad four pole change-over switch
16Amp. 415volts. Each
XV. Sheet metal/ iron clad four pole change-over switch
32Amp. 415volts. Each
XVI. Sheet metal/ iron clad four pole change-over switch
63Amp. 415volts. Each
XVII. Sheet metal/ iron clad four pole change-over switch
100Amp. 415volts. Each
XVIII. Sheet metal/ iron clad four pole change-over switch
200Amp. 415volts. Each
XIX. Sheet metal/ iron clad four pole change-over switch
320Amp. 415volts. Each
1 2 3
XX. Sheet metal/ iron clad four pole change-over switch
400Amp. 415volts. Each
XXI. Sheet metal/ iron clad four pole change-over switch
500Amp. 415volts. Each
31.14 IRON CLAD AIR CIRCUIT-BREAKERS:
Supply & erection of iron clad Air circuit breaker on the
existing industrial panel, including bonding to the existing
earth with suitable glands and making necessary connections
as required by the Engineer-in-Charge at site :-
1 2 3
IX. Miniature circuit breaker triple pole 5, 7.5, 10, 15, 16,
20,25 and 30Amp. suitable for 240/415volts 50cycles
A.C. supply. Each
X. Miniature circuit breaker triple pole 32Amp. suitable for
240/415volts 50cycles A.C. supply. Each
XI. Miniature circuit breaker triple pole 40, 50, 63Amp.
suitable for 240/415volts 50cycles A.C. supply. Each
XII. Miniature circuit breaker triple pole with neutral link 5,
7.5, 10, 15, 16, 20, 25 and 30Amp. suitable for
240/415volts 50cycles A.C. supply. Each
XIII. Miniature circuit breaker triple pole with neutral
link 32Amp. suitable for 240/415volts 50cycles
A.C.supply. Each
XIV. Miniature circuit breaker triple pole with neutral link 40,
50, 63Amp. suitable for 240/415volts 50cycles A.C.
supply. Each
XV. Miniature circuit breaker/ isolator single pole 32Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
XVI. Miniature circuit breaker/ isolator single pole 63Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
XVII. Miniature circuit breaker/ isolator single pole 100Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
XVIII. Miniature circuit breaker/ isolator double pole 32Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
XIX. Miniature circuit breaker/ isolator double pole 63Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
XX. Miniature circuit breaker/ isolator double
pole 100Amp. suitable for 240/415volts 50cycles
A.C.supply. Each
XXI. Miniature circuit breaker/ isolator triple pole 32Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
XXII. Miniature circuit breaker/ isolator triple pole 63Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
XXIII. Miniature circuit breaker/ isolator triple pole 100Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
31.16 XXIV. Miniature circuit breaker/ isolator four pole 32Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
XXV. Miniature circuit breaker/ isolator four pole 63Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
XXVI. Miniature circuit breaker/ isolator four pole 100Amp.
suitable for 240/415volts 50cycles A.C.supply. Each
31.17 SHEET METAL DISTRIBUTION BOARDS FOR (M.C.B'S/
ISOLATOR'S ) :
Supply and erection of sheet metal Distribution boards of
suitable size and of required number of ways for mounting
miniature circuit breakers/ Isolators including connections and
bonding to the existing earth:-
1 2 3
II. Sheet metal S.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating M.C.B.'s/Isolators, double pole oneway
each. Each
III. Sheet metal S.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating M.C.B.'s/Isolators, triple/ four pole
oneway each. Each
IV. Sheet metal S.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating M.C.B.'s/Isolators, 4way each.
Each
V. Sheet metal S.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating M.C.B.'s/Isolators, 6way each.
Each
VI. Sheet metal S.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating M.C.B.'s/Isolators, 8way each.
Each
VII. Sheet metal S.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating M.C.B.'s/Isolators, 12way each.
Each
VIII. Sheet metal S.P. & N. distribution Board
(dust protected provided with bus-bar, neutral-link and
din-bar, suitable for incorporating M.C.B.'s/Isolators,
16way each. Each
IX. Sheet metal T.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating S.P./ S.P. & N Isolators or cubical
switch for incoming and single pole M.C.B's for out going
4way each.
Each
X. Sheet metal T.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating S.P./ S.P. & N Isolators or cubical
switch for incoming and single pole M.C.B's for out going
6way each.
Each
31.17 XI. Sheet metal T.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating S.P./ S.P. & N Isolators or cubical
switch for incoming and single pole M.C.B's for out going
8way each.
Each
XII. Sheet metal T.P. & N. distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating S.P./ S.P. & N Isolators or cubical
switch for incoming and single pole M.C.B's for out going
12way each
Each
XIII. Sheet metal T.P. & N. (vertical design) distribution Board
(dust protected) provided with bus-bar, neutral-link and
din-bar, suitable for incorporating S.P./ S.P. & N., D.P. or
T.P&N.- M.C.B’s/ Isolators 4way each. Each
1 2 3
XIV. Sheet metal T.P. & N. (vertical design) distribution Board
(dust protected) provided with bus-bar, neutral-link and
din-bar, suitable for incorporating S.P./ S.P. & N., D.P. or
T.P&N.- M.C.B’s/ Isolators 8way each. Each
XV. Sheet metal T.P. & N. (vertical design) distribution Board
(dust protected) provided with bus-bar, neutral-link and
din-bar, suitable for incorporating S.P./S.P. & N., D.P. or
T.P&N.- M.C.B’s/ Isolators 12way each. Each
XVI. Sheet metal plug and socket distribution board single
pole and neutral enclosure with a two-pin and earth plug-
socket to incorporate one single pole M.C.B. 10Amp.
Each
XVII. Sheet metal plug and socket distribution board single
pole and neutral enclosure with a two-pin and earth plug-
socket to incorporate one single pole M.C.B. 20Amp.
Each
XVIII. Sheet metal plug and socket distribution board triple pole
and earth enclosure with a three-pin and earth plug with
socket to incorporate one triple pole M.C.B. 10Amp.
Each
XIX. Sheet metal plug and socket distribution board triple pole
and earth enclosure with a three-pin and earth plug with
socket to incorporate one triple pole M.C.B. 20Amp.
Each
XX. Sheet metal plug and socket distribution board triple pole
and earth enclosure with a three-pin and earth plug with
socket to incorporate one triple pole M.C.B. 30Amp.
Each
XXI. Sheet metal plug and socket distribution board triple pole
and earth enclosure with a three-pin and earth plug with
socket to incorporate one triple pole M.C.B. 60Amp.
Each
31.18 SHEET METAL BUS-BAR CHAMBERS (COPPER STRIPS):
1 2 3
II. Sheet metal Bus-Bar chamber suitable for 63Amp.
415volts capacity with 4 copper strip bus-bars each of
length 450mm and cross-sectional area (16mm x
3.17mm) enclosure having overall dimensions (530mm x
350mm x 150mm) nominal.
Each
III. Sheet metal Bus-Bar chamber suitable for 63Amp.
415volts capacity with 4 copper strip bus-bars each of
length 600mm and cross-sectional area (16mm x
3.17mm) enclosure having overall dimensions (680mm x
350mm x 150mm) nominal.
Each
IV. Sheet metal Bus-Bar chamber suitable for 100Amp.
415volts capacity with 4 copper strip bus-bars each of
length 300mm and cross-sectional area (25.4mm x
3.17mm) enclosure having overall dimensions (380mm x
400mm x 150mm) nominal.
Each
V. Sheet metal Bus-Bar chamber suitable for 100Amp.
415volts capacity with 4 copper strip bus-bars each of
length 450mm and cross-sectional area (25.4mm x
3.17mm) enclosure having overall dimensions (530mm x
400mm x 150mm) nominal.
Each
VI. Sheet metal Bus-Bar chamber suitable for 100Amp.
415volts capacity with 4 copper strip bus-bars each of
length 600mm and cross-sectional area (25.4mm x
3.17mm) enclosure having overall dimensions (680mm x
400mm x 150mm) nominal.
Each
VII. Sheet metal Bus-Bar chamber suitable for 100Amp.
415volts capacity with 4 copper strip bus-bars each of
length 900mm and cross-sectional area (25.4mm x
3.17mm) enclosure having overall dimensions (980mm x
400mm x 150mm) nominal.
Each
VIII. Sheet metal Bus-Bar chamber suitable for 100Amp.
415volts capacity with 4 copper strip bus-bars each of
length 1200mm and cross-sectional area (25.4mm x
3.17mm) enclosure having overall dimensions (1280mm
x 400mm x 150mm) nominal.
Each
31.18 IX. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 copper strip bus-bars each of
length 300mm and cross-sectional area (25.4mm x
4.75mm) enclosure having overall dimensions (380mm x
450mm x 150mm) nominal.
Each
X. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 copper strip bus-bars each of
length 450mm and cross-sectional area (25.4mm x
4.75mm) enclosure having overall dimensions (530mm x
450mm x 150mm) nominal.
Each
XI. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 copper strip bus-bars each of
length 600mm and cross-sectional area (25.4mm x
4.75mm) enclosure having overall dimensions (680mm x
450mm x 150mm) nominal.
Each
1 2 3
XII. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 copper strip bus-bars each of
length 900mm and cross-sectional area (25.4mm x
4.75mm) enclosure having overall dimensions (980mm x
450mm x 150mm) nominal.
Each
XIII. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 copper strip bus-bars each of
length 1200mm and cross-sectional area (25.4mm x
4.75mm) enclosure having overall dimensions (1280mm
x 450mm x 150mm) nominal.
Each
XIV. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 copper strip bus-bars each of
length 300mm and cross-sectional area (31.75mm x
6.35mm) enclosure having overall dimensions (380mm x
500mm x 200mm) nominal.
Each
XV. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 copper strip bus-bars each of
length 450mm and cross-sectional area (31.75mm x
6.35mm) enclosure having overall dimensions (530mm x
500mm x 200mm) nominal.
Each
XVI. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 copper strip bus-bars each of
length 600mm and cross-sectional area (31.75mm x
6.35mm) enclosure having overall dimensions (680mm x
500mm x 200mm) nominal.
Each
XVII. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 copper strip bus-bars each of
length 900mm and cross-sectional area (31.75mm x
6.35mm) enclosure having overall dimensions (980mm x
500mm x 200mm) nominal.
Each
XVIII. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 copper strip bus-bars each of
length 1200mm and cross-sectional area (31.75mm x
6.35mm) enclosure having overall dimensions (1280mm
x 500mm x 200mm) nominal.
Each
XIX. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 copper strip bus-bars each of
length 450mm and cross-sectional area (38.10mm x
6.35mm) enclosure having overall dimensions (530mm x
550mm x 200mm) nominal.
Each
31.18 XX. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 copper strip bus-bars each of
length 600mm and cross-sectional area (38.10mm x
6.35mm) enclosure having overall dimensions (680mm x
550mm x 200mm) nominal.
Each
XXI. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 copper strip bus-bars each of
length 900mm and cross-sectional area (38.10mm x
6.35mm) enclosure having overall dimensions (980mm x
550mm x 200mm) nominal.
Each
1 2 3
XXII. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 copper strip bus-bars each of
length 1200mm and cross-sectional area (38.10mm x
6.35mm) enclosure having overall dimensions (1280mm
x 550mm x 200mm) nominal.
Each
XXIII. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 copper strip bus-bars each of
length 1500mm and cross-sectional area (38.10mm x
6.35mm) enclosure having overall dimensions (1580mm
x 550mm x 200mm) nominal.
Each
XXIV. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 copper strip bus-bars each of
length 2000mm and cross-sectional area (38.10mm x
6.35mm) enclosure having overall dimensions (2080mm
x 550mm x 200mm) nominal.
Each
XXV. Sheet metal Bus-Bar chamber suitable for 500/630Amp.
415volts capacity with 4 copper strip bus-bars each of
length 450mm and cross-sectional area (50.80mm x
6.35mm) enclosure having overall dimensions (530mm x
600mm x 300mm) nominal.
Each
XXVI. Sheet metal Bus-Bar chamber suitable for 500/630Amp.
415volts capacity with 4 copper strip bus-bars each of
length 600mm and cross-sectional area (50.80mm x
6.35mm) enclosure having overall dimensions (680mm x
600mm x 300mm) nominal.
Each
XXVII. Sheet metal Bus-Bar chamber suitable for 500/630Amp.
415volts capacity with 4 copper strip bus-bars each of
length 900mm and cross-sectional area (50.80mm x
6.35mm) enclosure having overall dimensions (980mm x
600mm x 300mm) nominal.
Each
XXVIII. Sheet metal Bus-Bar chamber suitable for 500/630Amp.
415volts capacity with 4 copper strip bus-bars each of
length 1200mm and cross-sectional area (50.80mm x
6.35mm) enclosure having overall dimensions (1280mm
x 600mm x 300mm) nominal.
Each
XXIX. Sheet metal Bus-Bar chamber suitable for 500/630Amp.
415volts capacity with 4 copper strip bus-bars each
length 1500mm and cross-sectional area (50.80mm x
6.35mm) enclosure having overall dimensions (1580mm
x 600mm x 300mm) nominal. Each
XXX. Sheet metal Bus-Bar chamber suitable for 500/630Amp.
415volts capacity with 4 copper strip bus-bars each of
length 2000mm and cross-sectional area (50.80mm x
6.35mm) enclosure having overall dimensions (2080mm
x 600mm x 300mm) nominal.
Each
31.18 XXXI. Deleted
to XLV.
31.19 A SHEET METAL BUS-BAR CHAMBERS (ALUMINIUM
STRIPS):
1 2 3
Supply and erection of sheet metal bus-bar chamber on
existing surface with required No. of Bus-bar strips of suitable
length and cross-sectional area, made up of aluminium alloy or
wrought aluminium strips of suitable length and cross-
sectional area, enclosure made of M.S. sheet 1.6mm thick with
detachable cover, fitted with dust excluding gasket and
secured with sufficient No. of cadmium plated iron screws and
of given overall dimensions with a margin of ±5mm in size and
to be fixed with G.I. nuts & bolts/ rag bolts & nuts etc.,
complete with all accessories including connections with
suitable size of aluminium thimbles, bonding to the existing
earth and painting etc., as desired by the Engineer- in-charge
at site:-
1 2 3
31.19 VII. Sheet metal Bus-Bar chamber suitable for 100Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 900mm and
cross-sectional area (25mm x 6mm) enclosure having
overall dimensions (980mm x 400mm x 150mm)
nominal.
Each
VIII. Sheet metal Bus-Bar chamber suitable for 100Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 1200mm and
cross-sectional area (25mm x 6mm) enclosure having
overall dimensions (1280mm x 400mm x 150mm)
nominal.
Each
IX. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 300mm and
cross-sectional area (38mm x 6mm) enclosure having
overall dimensions (380mm x 450mm x 150mm)
nominal.
Each
X. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 450mm and
cross-sectional area (38mm x 6mm) enclosure having
overall dimensions (530mm x 450mm x 150mm)
nominal.
Each
XI. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 600mm and
cross-sectional area (38mm x 6mm) enclosure having
overall dimensions (680mm x 450mm x 150mm)
nominal.
Each
XII. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 900mm and
cross-sectional area (38mm x 6mm) enclosure having
overall dimensions (980mm x 450mm x 150mm)
nominal.
Each
XIII. Sheet metal Bus-Bar chamber suitable for 200Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 1200mm and
cross-sectional area (38mm x 6mm) enclosure having
overall dimensions (1280mm x 450mm x 150mm)
nominal.
Each
XIV. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 300mm and
cross-sectional area (51mm x 6mm) enclosure having
overall dimensions (380mm x 500mm x 200mm)
nominal.
Each
XV. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 450mm and
cross-sectional area (51mm x 6mm) enclosure having
overall dimensions (530mm x 500mm x 200mm)
nominal.
Each
1 2 3
31.19 XVI. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 600mm and
cross-sectional area (51mm x 6mm) enclosure having
overall dimensions (680mm x 500mm x 200mm)
nominal.
Each
XVII. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 900mm and
cross-sectional area (51mm x 6mm) enclosure having
overall dimensions (980mm x 500mm x 200mm)
nominal.
Each
XVIII. Sheet metal Bus-Bar chamber suitable for 300Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 1200mm and
cross-sectional area (51mm x 6mm) enclosure having
overall dimensions (1280mm x 500mm x 200mm)
nominal.
Each
XIX. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 450mm and
cross-sectional area (63mm x 6mm) enclosure having
overall dimensions (530mm x 550mm x 200mm)
nominal.
Each
XX. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 600mm and
cross-sectional area (63mm x 6mm) enclosure having
overall dimensions (680mm x 550mm x 200mm)
nominal.
Each
XXI. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 900mm and
cross-sectional area (63mm x 6mm) enclosure having
overall dimensions (980mm x 550mm x 200mm)
nominal.
Each
XXII. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 1200mm and
cross-sectional area (63mm x 6mm) enclosure having
overall dimensions (1280mm x 550mm x 200mm)
nominal.
Each
XXIII. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 1500mm and
cross-sectional area (63mm x 6mm) enclosure having
overall dimensions (1580mm x 550mm x 200mm)
nominal.
Each
XXIV. Sheet metal Bus-Bar chamber suitable for 400Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 2000mm and
cross-sectional area (63mm x 6mm) enclosure having
overall dimensions (2080mm x 550mm x 200mm)
nominal.
Each
1 2 3
31.19 XXV. Sheet metal Bus-Bar chamber suitable for 500Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 450mm and
cross-sectional area (76mm x 6mm) enclosure having
overall dimensions (530mm x 600mm x 300mm)
nominal.
Each
XXVI. Sheet metal Bus-Bar chamber suitable for 500Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 600mm and
cross-sectional area (76mm x 6mm) enclosure having
overall dimensions (680mm x 600mm x 300mm)
nominal.
Each
XXVII. Sheet metal Bus-Bar chamber suitable for 500Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 900mm and
cross-sectional area (76mm x 6mm) enclosure having
overall dimensions (980mm x 600mm x 300mm)
nominal.
Each
XXVIII. Sheet metal Bus-Bar chamber suitable for 500Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 1200mm and
cross-sectional area (76mm x 6mm) enclosure having
overall dimensions (1280mm x 600mm x 300mm)
nominal.
Each
XXIX. Sheet metal Bus-Bar chamber suitable for 500Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 1500mm and
cross-sectional area (76mm x 6mm) enclosure having
overall dimensions (1580mm x 600mm x 300mm)
nominal.
Each
XXX. Sheet metal Bus-Bar chamber suitable for 500Amp.
415volts capacity with 4 No. aluminium alloy or wrought
aluminium strip bus-bars each of length 2000mm and
cross-sectional area (76mm x 6mm) enclosure having
overall dimensions (2080mm x 600mm x 300mm)
nominal.
Each
XXXI. Deleted
to
XLIII.
31.19 B OVER-HEAD (TRUNKING) BUS-BAR CHAMBERS:
1 2 3
(c) Over head Bus-bar chamber 400Amp. 415volts (T.P.N.)
with 4 No. Aluminium Alloy or wrought Aluminium strips
of cross-section (63mmx6mm). Each
31.19B II. Supply and erection of bracket for suspension of over-
head bus-bar chamber made of two parallel G.I. pipes
15mm dia. 130cm long each with rubber reels and M.S.
flat clamps at the top ends of the G.I. pipes, suspended
from the existing cast iron boxes and with 50mm wide
12mm thick 51cm long M.S. flat at the other end of the
G.I. pipes with 2 nuts 6mm thick on each pipe and with
locking split pins.
Each
III. Supply and erection of Adopter boxes without S/F
but with stands, cable boxes and glands :-
(a) Suitable for 200Amp. 415volts (T.P.N.) Bus-bar
chamber. Each
(b) Suitable for 300Amp. 415volts (T.P.N.) Bus-bar
chamber. Each
(c) Suitable for 400Amp. 415volts (T.P.N.) Bus-bar
chamber. Each
IV. Supply and erection of 4 wire conduit end covers:-
1 2 3
(a) 16Amp. 415volts (T.P.N.) 4way. Each
(b) 16Amp. 415volts (T.P.N.) 6way. Each
(c) 32Amp. 415volts (T.P.N.) 4way. Each
(d) 32Amp. 415volts (T.P.N.) 6way. Each
31.19B (e) 63Amp. 415volts (T.P.N.) 2way. Each
VIII. (f) 63Amp. 415volts (T.P.N.) 4way. Each
(g) 63Amp. 415volts (T.P.N.) 6way. Each
(h) 100Amp. 415volts (T.P.N.) 4way. Each
(i) 100Amp. 415volts (T.P.N.) 6way. Each
IX. Supply and erection of Tap–Off–Boxes (T.P.N.) with
H.R.C. fuses and moulded fuse fittings including
connections as required :-
(a) Suitable for 16Amp. 415volts H.R.C. fuses. Each
(b) Suitable for 32Amp. 415volts H.R.C. fuses. Each
(c) Suitable for 63Amp. 415volts H.R.C. fuses. Each
(d) Suitable for 100Amp. 415volts H.R.C. fuses. Each
(e) Suitable for 200Amp. 415volts H.R.C. fuses. Each
X. Supply and erection of Aluminium Alloy or wrought
aluminium strip to be fixed in over head bus-bar
chamber duly insulated with P.V.C. Sleeve and
necessary attachment :-
(a) (38mm x 6mm) for 200Amp. 415volts O.H.B.B.C. Metre
(b) (51mm x 6mm) for 300Amp. 415volts O.H.B.B.C. Metre
(c) (63mm x 6mm) for 400Amp. 415volts O.H.B.B.C. Metre
31.20 A METAL BOARDS ( NICHE SIZE ) :
Supply and erection of metal clad boards for switch gear
mounting and of suitable size, with permissible variation in
size of ± 5mm, Frame work made of M.S. angle iron (50mm x
50mm x 6mm thick) duly welded and complete with 3mm thick
M.S. sheet fixed with hinges on the front and 1.6mm thick M.S.
sheet duly tag-welded at the rear, complete with locking
arrangement including painting and bonding to the existing
earth as required :-
1 2 3
III. Size (54cm x 40cm ) nominal. Each
IV. Size (71cm x 42.5cm) nominal. Each
V. Size (71cm x 60cm ) nominal. Each
VI. Size (22cm x 24cm ) nominal. Each
VII. Size (24cm x 26cm ) nominal. Each
31.20 (B) VIII. Size (24cm x 29cm ) nominal. Each
IX. Size (24cm x 38cm ) nominal. Each
X. Size (23cm x 29cm ) nominal. Each
XI. Size (30cm x 32cm ) nominal. Each
XII. Size (30cm x 41cm ) nominal. Each
XIII. Size (30cm x 46cm ) nominal. Each
XIV. Size (57cm x 22cm ) nominal. Each
XV. Size (57cm x 28cm ) nominal. Each
XVI. Size (57cm x 35cm ) nominal. Each
XVII. Size (65cm x 26cm ) nominal. Each
XVIII. Size (65cm x 33cm ) nominal. Each
XIX. Size (65cm x 40cm ) nominal. Each
XX. Size (34cm x 38cm ) nominal. Each
XXI. Size (36cm x 45cm ) nominal. Each
XXII. Size (42cm x 50cm ) nominal. Each
XXIII. Size (50cm x 60cm ) nominal. Each
XXIV. Size (60cm x 62cm ) nominal. Each
XXV. Size (62cm x 71cm ) nominal. Each
XXVI. Size (64cm x 82cm ) nominal. Each
XXVII. Size (85cm x 100cm ) nominal. Each
XXVIII. Deleted
(a to u)
XXIX. Deleted
(a to u)
31.20 C FLOOR MOUNTED FIXED TYPE METAL FRAME/
BOARDS:
Supply and erection of floor mounted fixed type metal frame
work/ boards of welded construction fabricated with M.S. angle
iron (50mm x 50mm x 6mm thick) & of suitable dimensions with
supporting members grouted 23cm underground and frame
work covered with 3mm thick M.S. sheet from top to a given
height with M.S. angle iron 50mm x 50mm x 6mm thick welded
on the back and grouted into the back wall complete with
painting, bonding to the existing earth etc., as required :-
1 2 3
31.20 (D) Supply and erection of sheet metal cubical pedestal of suitable
dimensions made from 50mm x 50mm x 6mm thick M.S. angle
iron frame, covered with 3mm thick M.S. sheet duly welded on
five sides & front side hinged, complete with locking
arrangement with 4 No. switch gear supporting members each
of M.S. flat 50mm x 6mm thick of suitable length duly welded.
The Cubical Pedestal shall have 4 No. legs of 50mm x 50mm x
6mm thick M.S. angle
1 2 3
31.20E XIV. Metal frame 202cm long, 22cm wide covered with M.S.
sheet 3mm thick (57cm x 22cm) from top. Each
XV. Metal frame 202cm long, 28cm wide covered with M.S.
sheet 3mm thick (57cm x 28cm) from top. Each
XVI. Metal frame 202cm long, 35cm wide covered with M.S.
sheet 3mm thick (57cm x 35cm) from top. Each
XVII. Metal frame 210cm long, 26cm wide covered with M.S.
sheet 3mm thick (65cm x 26cm) from top. Each
XVIII. Metal frame 210cm long, 33cm wide covered with M.S.
sheet 3mm thick (65cm x 33cm) from top. Each
XIX. Metal frame 210cm long, 40cm wide covered with M.S.
sheet 3mm thick (65cm x 40cm) from top. Each
XX. Metal frame 170cm long, 38cm wide covered with M.S.
sheet 3mm thick (34cm x 38cm) from top. Each
XXI. Metal frame 181cm long, 45cm wide covered with M.S.
sheet 3mm thick (36cm x 45cm) from top. Each
XXII. Metal frame 187cm long, 50cm wide covered with M.S.
sheet 3mm thick (42cm x 50cm) from top. Each
XXIII. Metal frame 195cm long, 60cm wide covered with M.S.
sheet 3mm thick (50cm x 60cm) from top. Each
XXIV. Metal frame 205cm long, 62cm wide covered with M.S.
sheet 3mm thick (60cm x 62cm) from top. Each
XXV. Metal frame 207cm long, 71cm wide covered with M.S.
sheet 3mm thick (62cm x 71cm) from top. Each
XXVI. Metal frame 209cm long, 82cm wide covered with M.S.
sheet 3mm thick (64cm x 82cm) from top. Each
XXVII. Metal frame 230cm long, 100cm wide covered with M.S.
sheet 3mm thick (85cm x 100cm) from top. Each
31.21 Deleted
31.22 Deleted
31.23 EARTHING OF METALLIC CASES ETC.:
I. Earthing of metallic cases etc., with G.I. wire No.
8S.W.G. (4mm dia.) in 15mm dia.G.I. pipe on surface
including painting etc., as required. Metre
II. Earthing of metallic cases etc., with G.I. wire No.
8S.W.G. (4mm dia.) in 15mm dia.G.I. pipe recessed in
wall and floor etc., as required. Metre
III. Earthing of metallic cases etc., with G.I. stranded wire
No. 7/14S.W.G. (7/2.18mm) in 15mm dia.G.I. pipe on
surface including painting etc., as required. Metre
IV. Earthing of metallic cases etc., with G.I. stranded wire
No. 7/14S.W.G. (7/2.18mm) in 15mm dia.G.I. pipe
recessed in wall and floor etc., as required. Metre
V. Earthing of metallic cases etc., with G.I. stranded wire
No. 7/12S.W.G. (7/2.80mm) in 20mm dia.G.I. pipe on
surface including painting etc., as required. Metre
VI. Earthing of metallic cases etc., with G.I. stranded wire
No. 7/12S.W.G. (7/2.80mm) in 20mm dia.G.I. pipe
recessed in wall and floor etc., as required. Metre
1 2 3
VII. Supply and erection of G.I. Earth pipe (50mm dia.)
135cm long, 4metre below ground level complete with
(50mm x 15mm) G.I. reducing socket (including boring &
refilling). Each
31.23 VIII. Earthing of Sheet metal/ Iron clad Switches and metallic
cases etc., with No. 8S.W.G. (4mm dia.) G.I. Wire in
15mm dia.G.I. Pipe partly recessed and partly on surface
complete with 135cm long 50mm dia.G.I. earth pipe with
G.I. reducing socket (50mm x 15mm) including erection
of the same, 4metre below ground level with necessary
charcoal & salt mixture etc., up to 9metre in length
(including boring & refilling).
Each
IX. Earthing of Sheet metal/ Iron clad Switches and metallic
cases etc., with No. 7/14S.W.G. (7/2.18mm) G.I.
Stranded Wire in 15mm dia.G.I. Pipe partly recessed and
partly on surface complete with 135cm long 50mm
dia.G.I. earth pipe with G.I. reducing socket (50mm x
15mm) including erection of the same, 4metre below
ground level with necessary charcoal & salt mixture etc.,
up to 9metre in length (including boring & refilling).
Each
X. Earthing of Sheet metal/ Iron clad Switches and metallic
cases etc., with No. 7/12S.W.G. (7/2.80mm) G.I.
Stranded Wire in 20mm dia.G.I. Pipe partly recessed and
partly on surface complete with 135cm long 50mm
dia.G.I. earth pipe with G.I. reducing socket (50mm x
20mm) including erection of the same, 4metre below
ground level with necessary charcoal & salt mixture etc.,
up to 9metre in length (including boring & refilling).
Each
XI. Earthing of Sheet metal/ Iron clad Switches and metallic
cases etc., with No. 8S.W.G. (4mm dia.) G.I. Wire in
15mm dia.G.I. Pipe partly recessed and partly on surface
complete with 135cm long 50mm dia.G.I. earth pipe with
G.I. reducing socket (50mm x 15mm) including erection
of the same, 3metre below ground level with necessary
charcoal & salt mixture etc., for hilly area up to 7.5metre
in length (including boring & refilling).
Each
XII. a. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (20mm x 3mm) thick copper tape rivetted
to (30cm x 120cm x 3mm thick) tinned copper plate
(made cylindrical) burried 4.5metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc., with
copper stapples of suitable size up to 9metre in length.
Each
1 2 3
b. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (25mm x 3mm) thick copper tape rivetted
to (30cm x 120cm x 3mm thick) tinned copper plate
(made cylindrical) burried 4.5metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc., with
copper stapples of suitable size up to 9metre in length.
Each
31.23 c. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (32mm x 3mm) thick copper tape rivetted
to (30cm x 120cm x 3mm thick) tinned copper plate
(made cylindrical) burried 4.5metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc., with
copper stapples of suitable size up to 9metre in length.
Each
XIII. Bonding to earth with 4mm dia. G.I. wire behind casing
or fixed with stapples on wall. Metre
XIV. a. Bonding to earth with 2.24mm dia. Bare aluminium wire
run on pyma–wood batton between P.V.C. cables.
Metre
b. Bonding to earth with 2mm dia. Bare copper wire run on
pyma-wood batton between P.V.C. cables. Metre
XV. a. Bonding to earth with G.I. wire No. 8S.W.G. (4mm dia.)
in 20mm dia. heavy gauge (1.6mm thick) welded conduit
pipe flushed. Metre
b. Bonding to earth with G.I. wire No. 8S.W.G. (4mm dia) in
20mm dia.heavy gauge (1.6mm thick) welded conduit
pipe on surface including painting etc. Metre
c. Bonding to earth with G.I. stranded wire No. 7/14S.W.G.
(7/2.18mm) in 20mm dia. heavy gauge (1.6mm thick)
welded conduit pipe flushed. Metre
d. Bonding to earth with G.I. stranded wire No. 7/14S.W.G.
(7/2.18mm) in 20mm dia. heavy gauge (1.6mm thick)
welded conduit pipe on surface including painting etc.
Metre
e. Bonding to earth with G.I. stranded wire No. 7/12S.W.G.
(7/2.80mm) in 25mm dia. heavy gauge (1.6mm thick)
welded conduit pipe flushed. Metre
f. Bonding to earth with G.I. stranded wire No. 7/12S.W.G.
(7/ 2.80mm) in 25mm dia. heavy gauge (1.6mm thick)
welded conduit pipe on surface including painting etc.
Metre
XVI. a. Supply and erection of 20mm x 3mm thick Copper Tape
(As additional length). Metre
b. Supply and erection of 25mm x 3mm thick Copper Tape
(As additional length). Metre
c. Supply and erection of 32mm x 3mm thick Copper Tape
(As additional length). Metre
XVII. Deleted
(a to h)
31.24 SUPPLY AND ERECTION OF FITTINGS:
I. Deleted
1 2 3
II. a. Supply and erection of Ceiling–rose bakelite surface
type. Each
b. Supply and erection of Ceiling–rose flush piano type. Each
III. to VI. Deleted
VII. a. Bakelite Batton holder large size. Each
b. Deleted
VIII. to IX. Deleted
Each
b. Erection only of 1x 20/ 40/ 65watts, 2x20/ 40/ 65watts,
60cm/120cm/150cm long fluorescent tube fittings by
means of 2 No. 20mm dia. Conduit pipe 1.6mm thick
with M.S. flanges of suitable size at the both ends
including 24/0.20mm (0.75mm²) flexible twin wire for
connecting the tube to the adjacent light point including
supply and erection of conduit pipe, flanges, flexible wire
& petty material required for the same (Upto 3.65metre
height).
Each
XVII. a. Erection only of 1x 20/ 40/ 65watts, 2x20/ 40/ 65watts,
60cm/120cm/150cm long fluorescent tube fittings by
means of 2 No. 20mm dia. Conduit pipe 1.6mm thick
with M.S. flanges of suitable size at the top ends
including 24/ 0.20mm (0.75mm²) flexible twin wire for
connecting the tube to the adjacent light point including
supply and erection of conduit pipe, flanges, flexible
cables & petty material required for the same (Above
3.65metre height).
Each
b. Erection only of 1 x20/ 40/ 65watts, 2x20/ 40/ 65watts,
60cm/ 120cm/ 150cm long fluorescent tube fittings by
means of 2 No. 20mm dia. Conduit pipe 1.6mm thick
with M.S. flanges of suitable size at the both ends
including 24/ 0.20mm (0.75mm²) flexible twin wire for
connecting the tube to the adjacent light point including
supply and erection of conduit pipe, flanges, flexible
cables & petty material required for the same (Above
3.65metre height).
Each
1 2 3
XVIII. a. Erection only of 1x 20/ 40/ 65watts, 2x20/ 40/ 65watts,
60cm/120cm/150cm long fluorescent tube fittings directly
on surface including necessary connections and supply
and erection of 24/ 0.20mm (0.75mm²) flexible twin wire
for connecting the fitting with the adjacent light point
(Without round blocks).
Each
b. Erection only of 1x 20/ 40/ 65watts, 2x20/ 40/ 65watts,
60cm/120cm/150cm long fluorescent tube fittings directly
on surface including necessary connections and supply
and erection of 24/ 0.20mm (0.75mm²) flexible twin wire
for connecting the fitting with the adjacent light point
(With round blocks).
Each
31.24 XIX. Deleted
XX. Deleted
XXI. a. Erection of Street light fittings suitable for G.I. pipe pole
80mm dia. including cost of G.I. pipe bracket having
nominal bore dia. 40mm and at least one metre in length
to give a total overhang at a tentative angle of 100/ 105
degree, the bracket should be fixed at the top of the pole
with G.I. reducer (80mm x 40mm) complete in all
respects as approved by the Engineer–in –Charge.
Each
b. Erection of Street light fittings suitable for G.I. pipe pole
100mm dia. including cost of G.I. pipe bracket having
nominal bore dia. 40mm and at least onemetre in length
to give a total overhang at a tentative angle of 100/105
degree, the bracket should be fixed at the top of the pole
with G.I. reducer (100mmx40mm) complete in all
respects as approved by the Engineer -in -Charge.
Each
XXII. Deleted
31.25 PAINTING INCLUDING LABOUR & MATERIAL:
I. Painting of Ceiling fan complete with blades, canopy,
suspension rod and regulator with two coats of approved
paint (with brush). Each
II. Painting rod pendant off sizes with two coats of
approved paint. Each
III. Painting Steel Tubular pole with cross arms with two
coats of aluminium or other approved paint:-
1 2 3
VI. a. Painting of Casing & Capping of light/ fan or call bell
point including mains & submains with two coats of
suitable paint (Excluding plug control). Each
b. Painting of Casing & Capping with two coats of an
approved paint (As extra length). Metre
VII. a. Painting of light/ fan or call bell points in P.V.C. sheathed
wiring system including mains & submains (Excluding
plug control). Each
b. Painting of P.V.C. sheathed wiring system with two coats
of an approved paint (As extra length). Metre
VIII. Painting of wood or metal surface with two coats of an
approved paint. Sq. Mtr.
31.25 IX. Painting of G.I./Conduit pipes with two coats of an
approved paint including cleaning the surface etc. :-
(a) 15mm dia.G.I. pipe & conduit pipe 20mm dia. Metre
(b) 20mm dia.G.I. pipe & conduit pipe 25mm dia. Metre
(c) 25mm dia.G.I. pipe & conduit pipe 32mm dia. Metre
IX. (d) 32mm dia.G.I. pipe & conduit pipe 40mm dia. Metre
(e) 40mm dia.G.I. pipe & conduit pipe 50mm dia. Metre
(f) G.I. Pipe 50mm dia. Metre
(g) G.I. Pipe 65mm dia. Metre
(h) G.I. Pipe 80mm dia. Metre
(i) G.I. Pipe 100mm dia. Metre
31.26 CARRIAGE & ERECTION OF FANS :
I. Carriage of Ceiling–Fan from local railway station or
P.W.D. office to site including erection of the same and
necessary P.V.C. insulated single core cable with
aluminium conductor 1.5mm² (1/1.40mm) left bare
(Unsheathed) for suspension rod and cutting threads
etc., on the rod.
Each
II. Carriage of Table fan from local railway station or local
P.W.D. office to site for erection. Each
III. a. Carriage from local railway station or local P.W.D. office
to site of an Exhaust fan including erection of the same.
Each
b. Carriage from local railway station or local P.W.D. office
to site of Cabin fan including erection of the same.
Each
IV. a. Making suitable size hole in the wall for 230mm sweep
Exhaust fan including finishing the same to the
satisfaction of the Engineer–in–Charge of the work.
Each
b. Making suitable size hole in the wall for 300mm sweep
Exhaust fan including finishing the same to the
satisfaction of the Engineer–in–Charge of the work.
Each
c. Making suitable size hole in the wall for 380mm sweep
Exhaust fan including finishing the same to the
satisfaction of the Enginee–in–Charge of the work. Each
1 2 3
d. Making suitable size hole in the wall for 450mm sweep
Exhaust fan including finishing the same to the
satisfaction of the Engineer–in–Charge of the work. Each
e. Making suitable size hole in the wall for 610mm sweep
Exhaust fan including finishing the same to the
satisfaction of the Engineer–in–Charge of the work. Each
V. a. Providing & Fixing 38.1cm x 38.1cm wooden frame
32mm thick 50mm wide of Deodar wood for 230mm
sweep Exhaust fan. Each
b. Providing & Fixing 45.72cm x 45.72cm wooden frame
32mm thick, 50mm wide of Deodar wood for 300mm
sweep Exhaust fan. Each
c. Providing & Fixing 52.5cm x 52.5cm wooden frame
32mm thick, 50mm wide of Deodar wood for 380mm
sweep Exhaust fan. Each
31.26 d. Providing & Fixing 60cm x 60cm wooden frame 32mm
thick, 50mm wide of Deodar wood for 450mm sweep
Exhaust fan. Each
e. Providing & Fixing 76.2cm x 76.2cm wooden frame
32mm thick, 50mm wide of Deodar wood for 610mm
sweep Exhaust fan. Each
VI. Carriage of Pedestal fan from local Government store/
office to site for erection. Each
31.27 REPAIR & REWINDING OF FANS :
31.27 I. a. Full Stator rewinding of a Ceiling Fan (Condensor type)
of 900mm sweep, including cleaning & insulating the
stator slots, sleeving, soldering, wrapping of cotton tape,
varnishing, re–assembling & testing etc., complete.
Each
b. Full Stator rewinding of a Ceiling Fan (ondensor type) of
1200mm sweep, including cleaning & insulating the
stator slots, sleeving, soldering, wrapping of cotton tape,
varnishing, re-assembling & testing etc., complete.
Each
c. Full Stator rewinding of a Ceiling Fan (Condensor type)
of 1400mm/ 1500mm sweep, including cleaning &
insulating the stator slots, sleeving, soldering, wrapping
of cotton tape, varnishing, re–assembling & testing etc.,
complete. Each
d. Full Stator rewinding of a Ceiling Fan (Condensor type)
of 1800mm sweep, including cleaning & insulating the
stator slots, sleeving, soldering, wrapping of cotton tape,
varnishing, re–assembling & testing etc., complete.
Each
e. Replacement of a Single Stator coil of a Ceiling Fan
(Condensor type) of 900mm sweep including
connections, providing insulation, varnishing, re–
assembling & testing etc. Each
f. Replacement of a Single Stator coil of a Ceiling Fan
(Condensor type) of 1200mm sweep including
connections, providing insulation, varnishing, re–
assembling & testing etc. Each
1 2 3
g. Replacement of a Single Stator coil of a Ceiling Fan
(Condensor type) of 1400mm/ 1500mm sweep including
connections, providing insulation, varnishing, re–
assembling & testing etc. Each
h. Replacement of a Single Stator coil of a Ceiling Fan
(Condensor type) of 1800mm sweep including
connections, providing insulation, varnishing, re–
assembling & testing etc. Each
II. a. Full Stator rewinding of a Ceiling Fan (Non-Condensor
type) of 1200mm sweep, including cleaning & insulating
the stator slots, sleeving, soldering, wrapping of cotton
tape, varnishing, re-assembling & testing etc., complete.
Each
b. Full Stator rewinding of a Ceiling Fan (Non-Condensor
type) of 1400mm sweep, including cleaning & insulating
the stator slots, sleeving, soldering, wrapping of cotton
tape, varnishing, re-assembling & testing etc.,complete.
Each
31.27 c. Full Stator rewinding of a Ceiling Fan (Non-Condensor
type) of 1500mm sweep, including cleaning & insulating
the stator slots, sleeving, soldering, wrapping of cotton
tape, varnishing, re-assembling & testing etc., complete.
Each
d. Replacement of a Single Stator coil of a Ceiling Fan
(Non-Condensor type) of 1200mm sweep including
connections, providing insulation, varnishing, re–
assembling & testing etc., complete. Each
e. Replacement of a Single Stator coil of a Ceiling Fan
(Non-Condensor type) of 1400mm sweep including
connections, providing insulation, varnishing, re–
assembling & testing etc., complete.
Each
f. Replacement of a Single Stator coil of a Ceiling Fan
(Non-Condensor type) of 1500mm sweep including
connections, providing insulation, varnishing, re–
assembling & testing etc., complete.
Each
III. a. Full Stator rewinding of an Exhaust Fan (Condensor
type) of 230mm/ 300mm sweep, 900 R.P.M. including
cleaning & insulating the stator slots, sleeving, soldering,
wrapping of cotton tape, varnishing, re–assembling &
testing etc., complete.
Each
b. Full Stator rewinding of an Exhaust Fan (Condensor
type) of 230mm/ 300mm sweep, 1400 R.P.M. including
cleaning & insulating the stator slots, sleeving, soldering,
wrapping of cotton tape, varnishing, re–assembling &
testing etc., complete.
Each
c. Full Stator rewinding of an Exhaust Fan (Condensor
type) of 380mm sweep, 900 R.P.M.including cleaning &
insulating the stator slots, sleeving, soldering, wrapping
of cotton tape, varnishing, re–assembling & testing etc.,
complete.
Each
1 2 3
d. Full Stator rewinding of an Exhaust Fan (Condensor
type) of 380mm sweep, 1400 R.P.M. including cleaning
& insulating the stator slots, sleeving, soldering,
wrapping of cotton tape, varnishing, re–assembling &
testing etc., complete.
Each
e. Full Stator rewinding of an Exhaust Fan (Condensor
type) of 450mm sweep, 900 R.P.M. including cleaning &
insulating the stator slots, sleeving, soldering, wrapping
of cotton tape, varnishing, re – assembling &
testing etc., complete.
Each
f. Full Stator rewinding of an Exhaust Fan (Condensor
type) of 450mm sweep, 1400 R.P.M. including cleaning
& insulating the stator slots, sleeving, soldering,
wrapping of cotton tape, varnishing, re–assembling &
testing etc., complete. Each
g. Full Stator rewinding of an Exhaust Fan (Condensor
type) of 610mm sweep, 900 R.P.M. including cleaning &
insulating the stator slots, sleeving, soldering, wrapping
of cotton tape, varnishing, re–assembling & testing etc.,
complete. Each
31.27 h. Full Stator rewinding of an Exhaust Fan (Condensor
type) of 610mm sweep, 1400 R.P.M. including cleaning
& insulating the stator slots, sleeving, soldering,
wrapping of cotton tape, varnishing, re–assembling &
testing etc., complete. Each
i. Replacement of a Single Stator coil of an Exhaust Fan
(Condensor type) of 230mm/ 300mm sweep (Any
R.P.M.) including connections, providing insulation,
varnishing, re–assembling & testing etc. Each
III. j. Replacement of a Single Stator coil of a Exhaust Fan
(Condensor type) of 380mm sweep (Any R.P.M.)
including connections, providing insulation, varnishing,
re–assembling & testing etc. Each
k. Replacement of a Single Stator coil of a Exhaust Fan
(Condensor type) of 450mm sweep (Any R.P.M.)
including connections, providing insulation, varnishing,
re–assembling & testing etc. Each
l. Replacement of a Single Stator coil of a Exhaust Fan
(Condensor type) of 610mm sweep (Any R.P.M.)
including connections, providing insulation, varnishing,
re-assembling & testing etc. Each
IV. a. Full Stator rewinding of a Table/ Pedestal Fan
(Condensor type) of 1440 R.P.M. of any sweep,
including cleaning & insulating the stator slots, sleeving,
soldering, wrapping of cotton tape, varnishing, re–
assembling & testing etc., complete.
Each
b. Full Stator rewinding of a Table/ Pedestal Fan
(Condensor type) of 2800 R.P.M. of any sweep,
including cleaning & insulating the stator slots, sleeving,
soldering, wrapping of cotton tape, varnishing, re–
assembling & testing etc., complete.
Each
V. a. Replacement of a Ball–bearing of a Ceiling fan including
greasing, re–assembling & testing etc. Each
1 2 3
b. Replacement of a Bush–bearing of any fan including
turning, oiling, re – assembling and testing etc. Each
c. Replacement of a Thrust–bearing (Small size) of any fan
including oiling, greasing, re-assembling & testing etc.
Each
d. Replacement of a Thrust–bearing (Large size) of any fan
including oiling, greasing,
re-assembling & testing etc. Each
e. Providing & Fixing locking/ split pins in ceiling fans of any
size including drilling of holes re –assembling & testing
etc. Each
f. Replacement of Blade–shank of suitable size of a Ceiling
fan with screws, nuts, spring washers etc., as required.
Each
g. Replacement of Hanger–shackle with nuts, bolts & split
pin for a ceiling fan of any size. Each
h. Replacement of a Rubber reel. Each
i. Replacement of a Fan–socket for a Ceiling fan including
drilling of holes for split–pin etc. Each
j. Replacement of a Fan condensor (2 to 2.5) micro–farad
complete with connections & testing etc. Each
31.27 k. Replacement of a Fan condensor (3) micro–farad
complete with connections & testing etc. Each
l. Replacement of a Fan condensor (4) micro–farad
complete with connections & testing etc. Each
m. Replacement of a Fan condensor (6) micro–farad
complete with connections & testing etc. Each
n. Replacement of a Fan condensor (8) micro–farad
complete with connections & testing etc. Each
o. Replacement of Speed regulator knob. Each
p. Replacement of Speed regulator rotary switch without
knob including connections & testing etc. Each
V. q. Replacement of Speed regulator resistance coils
including connections & testing etc. Each
r. Replacement of Speed regulator china plates complete
with nuts and screws etc. Each
s. Replacement of complete assembly of Speed regulator
resistance coils wound on china plates duly insulated
with mica sheet. Each
t. Painting of a Ceiling fan complete with blades, canopy,
suspension rod and speed regulator (with spray painting)
complete. Each
u. Painting of a Ceiling fan complete with blades, canopy,
suspension rod and speed regulator (with stove
enamelled paint) complete. Each
31.28 OVER-HEAD DISTRIBUTION:
I. a. Labour for dismantling steel tubular or G.I. pipe pole. Each
b. Labour for dismantling pre-stressed cement concrete
pole. Each
II. Dismantling of anchor rod complete. Each
1 2 3
III. a. Erection of steel tubular/ G.I. pipe pole upto 7m length in
cement concrete 1:3:6 including cement concrete 1:2:4
collar but excluding cost of pole including painting etc.
Each
b. Erection of steel tubular pole exceeding 7m length upto
10m length in cement concrete 1:3:6 including cement
concrete 1:2:4 collar but excluding cost of pole including
painting etc. Each
c. Erection of P.C.C. pole (having drawing-in cable
arrangement) over a slab of cement concrete 1:2:4, 0.5
sq. m 15cm thick including cement concrete 1:4:8 filling
around the pole upto ground level but excluding cost of
P.C.C. pole.
Each
d. Erection of P.C.C. pole over a slab of cement concrete
1:3:6, 0.5sq.m 15cm thick but excluding cost of P.C.C.
pole (upto 9.14m length). Each
e. Erection of P.C.C. pole over a slab of cement concrete
1:3:6, 0.5sq.m 15cm thick but excluding cost of P.C.C.
pole (11m length). Each
31.28 f. Erection only of three stepped steel tubular swaged and
welded pole conforming to I.S. 2713/ 1969 or I.S. 2713
(Part I to III) 1980 for under ground wiring system overall
length from 7metre to 10metre in cement concrete 1 :3 :6
including cement concrete 1 :2 :4 collar 45cm high from
ground level complete with 1:2 plaster 6mm thick,
excluding the cost of pole but including painting etc., as
required.
Each
IV. Supply and erection of bracket steel channel 75mm x
40mm (2 line). Each
V. Supply and erection of bracket steel channel 75mm x
40mm (4 line). Each
VI. a. Supply and erection of anchor rod Henly type for pole
including necessary clamps and 7/2.80mm G.I. stay wire
in cement concrete 1: 3 : 6. Each
b. Supply and erection of anchor rod Henly type for pole
including necessary clamps and 7/3.15mm G.I. stay wire
in cement concrete 1: 3 : 6. Each
VI. c. Supply and erection of anchor rod Henly type for pole
including necessary clamps and 7/4mm G.I. stay wire in
cement concrete 1: 3: 6. Each
d. Supply and erection of Strain insulator as required at
site. Each
e. Supply and erection of Cradle guard suitable for 2 lines
over head line as required at site Each
f. Supply and erection of Cradle guard suitable for 4 lines
over head line as required at site. Each
g. Supply and erection of Hexagonal guard suitable for 2
lines over head line (Vertical distribution) as required at
site. Each
h. Supply and erection of Hexagonal guard suitable for 4
lines over head line (Vertical distribution) as required at
site. Each
1 2 3
VII. Supply and erection of stay for house service pipe
complete with straining screw 7/1.6mm G.I. stay wire.
Each
VIII. Erection only of anchor rod for pole in cement concrete
1:3:6 but excluding cost of anchor rod. Each
IX. Supply and erection of cast iron reel size 75mm x 50mm
dia. Each
X. Supply and erection of house service pipe Henly type or
pole type 50mm dia., 6metre long for bare Aluminium
conductor over head line without straining device or
shackle insulator including painting.
Each
XI. Supply and erection of house service bracket wall type of
50mm dia.G.I. pipe of approved design including painting
as required for 2 line Each
XII. Supply and erection of house service bracket wall type of
50mm dia.G.I. pipe of approved design including painting
as required for 4 line. Each
XIII. Supply and erection of lightning arrestor horn type
complete with 100mm x 65mm pin insulator, spindle and
brass metal parts heavy type. Each
XIV. Supply and erection of shackle insulator (medium) with
fixing bolts and nuts. Each
31.28 XV. a. Supply and erection of 100mm x 65mm pin insulator
complete with G.I. spindle and nuts etc. Each
b. Supply and erection of 100mm x 80mm pin insulator
complete with G.I. spindle and nuts etc. Each
XVI. Supply and erection of G.I. wire No. 8S.W.G. (4mm dia.)
above on pole including binding wire. Kg.
XVII. Binding of shackle or copper wire joint with bare copper
binding wire. Kg.
XVIII. Binding of cast iron reel or G.I. wire joint with G.I. binding
wire (2.16mm dia). Each
XIX. Dismantling only of over head lines comprising of G.I. or
copper or A.C.S.R. or A.A.C. conductor including cross-
arms and insulators etc., and taking down to the ground.
Kg.
XX. a. Supply and erection of A.C.S.R. (7/2.11mm to 7/3mm
dia.) including Kg.
b. Supply and erection of A.C.S.R. (7/3.35mm dia. &above)
including binding of insulator with binding wire.
Kg.
XX. c. Supply and erection of A.A.C. conductor (7/1.96mm to
7/3.10mm dia.) including binding of insulator with binding
wire. Kg.
d. Supply and erection of A.A.C. conductor (7/3.40mm dia
& above) including binding of insulator with binding wire.
Kg.
e. Erection only of G.I. wire (No. 8S.W.G. to No. 4S.W.G.)
including binding with C.I. reel with G.I. binding wire.
Kg.
f. Erection only of A.C.S.R. (7/2.11mm to 7/3mm dia.)
including binding of insulator with binding wire. Kg.
1 2 3
g. Erection only of A.C.S.R. (7/3.35mmdia and above)
including binding of insulator with binding wire. Kg.
h. Erection only of A.A.C (7/1.96mmto 7/3.10mm) including
binding of insulator with binding wire. Kg.
i. Erection only of A.A.C (7/3.40mmdia and above)
including binding of insulator with binding wire. Kg.
XXI. Supply and erection of G.I. shackle straps with 11.25cm
long bolts and nuts. Pair
XXII. Supply and erection of special type clamps for fixing the
C.I. reels on top of poles where the same cannot be
fixed on brackets. Each
XXIII. Supply and erection of additional length of house service
G.I. pipe 50mm dia. Metre
XXIV. Supply and erection of house service G.I. pipe 50mm
dia.3 m long for insulated over head line complete with
cast iron cap of suitable size and ways, shackle insulator
and straining device including necessary P.V.C. bushes
for protecting the incoming & outgoing lead and flat iron
support 50mm x 6mm x 22.5cm long and painting as
required.
Each
XXV. Wiring over-head line in two single core cable with
aluminium conductor, insulated with P.V.C. and
polythene sheathed overall 1100volts grade on G.I. wire
4mm dia. With brass/ aluminium link clips cable size
1.5mm² (1/1.40mm).
Metre
31.28 XXVI. Wiring over-head line in two single core cable with
aluminium conductor, insulated with P.V.C. and
polythene sheathed overall 1100volts grade on G.I. wire
4mm dia. With brass/ aluminium link clips cable size
2.5mm² (1/1.80mm).
Metre
XXVII. Wiring over-head line in two single core cable with
aluminium conductor, insulated with P.V.C. and
polythene sheathed overall 1100volts grade on G.I. wire
4mm dia. With brass/ aluminium link clips cable size
4mm² (1/2.24mm).
Metre
XXVIII. Wiring over-head line in two single core cable with
aluminium conductor, insulated with P.V.C. and
polythene sheathed overall 1100volts grade on G.I. wire
4mm dia. With brass/ aluminium link clips cable size
6mm² (1/2.80mm).
Metre
XXIX. Wiring over-head line in two single core cable with
aluminium conductor, insulated with P.V.C. and
polythene sheathed overall 1100volts grade on G.I. wire
4mm dia. With brass/ aluminium link clips cable size
10mm² (1/3.55mm).
Metre
XXX. Wiring over-head line in two single core cable with
aluminium conductor, insulated with P.V.C. and
polythene sheathed overall 1100volts grade on G.I. wire
4mm dia. With brass/ aluminium link clips cable size
16mm² (7/1.70mm).
Metre
1 2 3
XXXI. Wiring over-head line in two single core cable with
aluminium conductor, insulated with P.V.C. and
polythene sheathed over-all 1100volts grade on G.I. wire
4mm dia. With brass/ aluminium link clips cable size
25mm² (7/2.24mm).
Metre
XXXII. Supply and erection of ‘D’ iron clamp 50mm x 6mm flat
iron complete with fixing bolts and nuts including making
holes in pole. Each
XXXIII. Supply and erection of ‘EYE’ rag bolts 22.5cm x 16mm.
Each
XXIV. Dismantling of house service pipe complete with channel
brackets including necessary repair to the entire
satisfaction of Engineer-In-Charge. Each
31.28 XXXV. Supply and erection of G.I. pipe ‘A’ quality of
suitable length and dia.conforming to I.S. 1239 part-I
1979, including fixing up to a given depth below G/L,
the hole of excavation about 30cm dia. and given
depth to be filled in up to 15cm below G/L with 1:3:6
cement concrete and there above a plinth with 1:2:4
cement concrete up to a height of 45cm from G/L.The
radial thick ness of the plinth above G/L should not
be less than 6.35cm and sufficient to completely
flush a mild steel fuse box 15cm x 15cm x 6.35cm
deep having 16Amp. 240volts kit-kat fuse unit fixed
on single teak –wood board of the same size the
outer surface of the plinth to be finished with 1:2
cement plaster 6mm thick M.S. fuse box shall have a
water proof hinged cover with locking arrangement
including painting of pole with two coats of approved
aluminium paint as required:-
1 2 3
XXXVI. Supply and erection of 3-Stepped steel tubular
swaged and welded pole of suitable length
conforming to I.S. 2713-1969 (Part I to III)/ 1980 to
fixed up to a required planting depth below ground
level in a hole of excavation about 30cm dia. and
suitable depth to filled in up to 15cm below G/L with
1:3:6 cement concrete and up to a height of 45cm
above G/L with 1:2:4 cement concrete plinth with
radial thickness not less than 6.35cm sufficient to
completely flush a mild steel fuse box 15cm x 15cm
x 6.35cm deep with hinged water tight cover with
locking arrangement having 32Amp. 240volts kit-kat
fuse unit fixed on single teak –wood board of the
same size. The outer surface of the plinth to be
finished with 1:2 cement plaster 6mm thick including
painting of pole with two coats of approved
aluminium paint as required:-
1 2 3
XXXVI. f. Overall length 10metre, with planting depth 1.8metre,
length of sections 5.20metre, 2.40metre and 2.40metre
(Bottom, Middle and Top respectively), Outer dia. and
thickness of sections165.1mm x 4.85mm,139.7mm x
4.5mm and 114.3mm x 3.65mm (Bottom, Middle and
Top respectively) with approximate weight 168kg with
base plate 12mm thick and about 30cm dia.
Each
XXXVI. g. Supply and erection of 3-Stepped steel tubular
swaged and welded pole of suitable length
conforming to I.S. 2713-1969 or I.S. 2713 (Part I to III)/
1980 for over head lines to fixed up to a required
planting depth below ground level in a hole of
excavation about 30cm dia. and suitable depth to
filled in up to 15cm below G/L with 1:3:6 cement
concrete and there above a plinth with 1:2:4 cement
concrete up to a height of 23cm above G/L with
1 2 3
XXXVI. g Overall length 9metre, with planting depth 1.5metre,
(iv) length of sections 5metre, 2metre and 2metre (Bottom,
Middle and Top respectively), Outer dia and thickness of
sections 165.1mm x 4.85mm, 139.7mm x 4.5mm and
114.3mm x 3.65mm (Bottom, Middle and Top
respectively) with approx. weight 154kg with base plate
12mm thick and about 30cm dia. in case of pole
conforming to I.S. 2713 (Part I to III)/ 1980.
Each
(v) Overall length 9.5metre, with planting depth 1.8metre,
length of sections 5metre, 2.25metre and 2.25metre
(Bottom, Middle and Top respectively), Outer dia and
thickness of sections 165.1mm x 4.85mm, 139.7mm x
4.5mm and 114.3mm x 3.65mm (Bottom, Middle and
Top respectively) with approx. weight 160kg with base
plate 12mm thick and about 30cm dia. in case of pole
conforming to I.S. 2713 (Part I to III)/ 1980.
Each
(vi) Overall length 10metre, with planting depth 1.8metre,
length of sections 5.2metre, 2.4metre and 2.4metre
(Bottom, Middle and Top respectively), Outer dia and
thickness of sections 165.1mm x 4.85mm, 139.7mm x
4.5mm and 114.3mm x 3.65mm (Bottom, Middle and
Top respectively) with approx. weight 168kg with base
plate 12mm thick and about 30cm dia. in case of pole
conforming to I.S. 2713 (Part I to III)/ 1980.
Each
XXXVII. Deleted
XXXVIII. Deleted
(a to e)
XXXIX. Supply and erection of G.I. pipe along the pole for
protection of under ground cables (up to 3metre in
length) :-
a. G.I. pipe 50mm dia. Each
b. G.I. pipe 80mm dia. Each
c. G.I. pipe 100mm dia. Each
XL. Supply and erection of Aerial fuse :-
a. 15Amp. Each
b. 30Amp. Each
31.28 XLI. a. Supply and erection of 40mm dia x 1.5metre long G.I.
pipe bracket of required shape for mounting a
fluorescent street light fitting on steel tubular pole of any
size with 2 No. M.S. flat iron 50mm x 6mm thick clamps
of required shape including connections, erection of the
fitting and painting etc., with two coats of an approved
aluminium paint as desired by the Engineer–in–charge at
site.
Each
b. Supply and erection of clamps of desired shape (For
steel tubular pole) for street light bracket including
painting etc., with two coats of an approved aluminium
paint as desired by the Engineer–in–charge at site.
Each
1 2 3
XLI. c. Supply and erection of 40mm dia x 2.9metre long G.I.
pipe bracket of required shape for mounting a mercury/
sodium vapour lamp street light fitting on steel tubular
pole of any size and bracket to be fixed on the top of
pole, duly welded with a suitable ring and pipe
arrangement about 20cm overlap and fixed by means of
cross bolts and nuts complete with check nuts, including
connections, erection of the fitting and painting the same
with two coats of an approved aluminium paint as
desired by the Engineer–in–charge at site.
Each
d. Supply and erection of 40mm dia x 2.9metre long G.I.
pipe bracket of required shape for mounting a
fluorescent street light fitting on steel tubular pole of any
size and bracket to be fixed on the top of pole, duly
welded with a suitable ring and pipe arrangement about
20cm overlap and fixed by means of cross bolts and nuts
complete with check nuts, including connections,
erection of the fitting and painting the same with two
coats of an approved aluminium paint as desired by the
Engineer–in–charge at site.
Each
e. Supply and erection of 40mm dia x 1.22metre long G.I.
pipe bracket of required shape for mounting a
fluorescent street light fitting on P.C.C. Pole of any size,
including connections and painting the same with two
coats of an approved aluminium paint as desired by the
Engineer–in–charge at site.
Each
f. Supply and erection of 40mm dia x 1.5metre long G.I.
pipe bracket of required shape for mounting a
fluorescent street light fitting on P.C.C. Pole of any size
with 2 No. M.S. flat iron 50mm x 6mm thick clamps of
required shape including connections, erection of the
fitting and painting the same with two coats of an
approved aluminium paint as desired by the Engineer–
in–charge at site.
Each
g. Supply and erection of clamps of desired shape For
P.C.C. pole) for street light bracket including painting
etc., with two coats of an approved aluminium paint as
desired by the Engineer–in–charge at site.
Each
31.29 MISCELLANEOUS:-
I. Supply and erection of 20mmdia G.I. suspension rod for
ceiling fan. Metre
31.29 II. Supply and erection of 15mmdia G.I. suspension rod for
ceiling fan. Metre
III. Supply and erection of Girder clamp for ceiling fan. Each
IV. Supply and erection of Girder strut of 50mm x 6mm ‘T’
section steel for suspension of fan complete with fan
clamp including painting as required up to 1.5metre
span. Each
V. Supply and erection of additional length of ‘T’section
steel for girder strut including painting as required. Metre
VI. Laying under ground cable 1metre below ground level
covered with sand and bricks. Metre
VII. to X. Deleted
1 2 3
XI. Supply and erection of special iron channel 75mm x
40mm wall bracket, 60cm long for converting ceiling fans
in to cinema type bracket including painting etc. Each
XII. Supply and erection of special beam clamp including
supply of suspension hook for fan. Each
XIII. Writing caution notice in three languages. Job
XIV. Supply and erection of Shock restoration chart in glass
frame. Job
XV. Supply and erection of M.S. Roof suspension for fan of
75mm wide, 12.5mm thick and 45cm long iron plate with
necessary suspension hook including covering the plate
with cement concrete 1 : 3 : 6.
Each
XVI. Supply and erection of 75mm x 40mm steel channel
120cm long with necessary suspension hook including
covering the channel with cement concrete
1 : 3 : 6. Each
XVII. a. Supply and erection of 16mm dia, 90cm long Mild steel
rod made in suitable fan suspension hook placed and
erected in R.C.C. slab for erection of fan.
Each
b. Supply and erection of 12mm dia, 90cm long Mild steel
rod made in suitable fan suspension hook placed and
erected in R.C.C. slab for erection of fan. Each
XVIII. a. Supply and erection of 12mm dia, 30cm long Mild steel
rod made in suitable fan suspension hook “S” type. Each
b. Supply and erection of Cast iron fan box (18cm x 10cm x
10cm) with M.S. sheet cover (1.6mm thick) and M.S.
round 16mm/ 12mm dia. 60cm long complete.
Each
XIX. Numbering of Ceiling/ Exhaust fans as required. Each
XX. Supply and erection of S.W./ G.I./ C.I./ M.S. pipe
across the road including remetalling the same to
the original form :-
(a). S.W. Pipe 100mm dia. Metre
(b). Galvanised iron pipe 100mm dia. Metre
(c). Cast iron pipe 100mm dia. Metre
(d). Mild steel pipe 100mm dia. Metre
XXI. a. Supply and erection of Kit-kat fuse unit 16Amp. 240volts
in the existing M.S./ C.I. box (Including connections).
Each
b. Supply and erection Kit-kat fuse unit 32Amp. 240volts in
the existing M.S./ C.I. box (Including connections). Each
31.29 XXII. Supply and erection of M.S. sheet danger notice
plate at least 2mm thick and vitreous enameled white
on both sides and with inscriptions in the signal red
colour on the front side as required :-
(a). Size (71mm x 142mm). Each
(b). Size (142mm x 142mm). Each
(c). Size (142mm x 192mm). Each
(d). Size (192mm x 285mm). Each
XXIII. Supply and erection of suitable compression type
cable socket–gland for under ground cable:-
(a). Up to 2.5mm ² cable. Each
1 2 3
(b). Exceeding 2.5mm² cable but up to 10mm² cable. Each
XXIII. (c). Exceeding10mm² cable but up to 25mm² cable. Each
(d). Exceeding 25mm² cable but up to 50mm² cable. Each
(e). Exceeding 50mm² cable but up to 95mm² cable. Each
(f). Exceeding 95mm² cable but up to 150mm² cable. Each
(g). Exceeding 150mm² cable but up to185mm² cable. Each
(h). Exceeding 185mm² cable but up to 300mm² cable. Each
(i). Exceeding 300mm² cable but up to 400mm² cable. Each
31.30 Deleted
31.31 LIGHTNING CONDUCTOR :
I. a. Supply and erection of 25mm dia., 0.91meter long
tapered in to a point at the top (G.I. rod). Each
b. Supply only of 25mm dia.G.I. rod (Extra length). Metre
II. Erection only of G.I. 7/ 10S.W.G. (10mm dia.) stranded
flexible lightning conductor wire including supply of
suitable iron clamps. Metre
III. Supply and erection of G.I. 7/10S.W.G. (10mm dia.)
stranded flexible lightning conductor wire including
supply of suitable iron clamps. Metre
IV. Providing stranded watering tank (30cm x 30cm x 30cm)
complete with 3mm thick galvanised iron plate cover
provided with chain & locking arrangement. Job
V. Supply and erection of earth electrode of 20mmdia.,
2.75metre long G.I. pipe from ground level, connecting
the 50mm dia.,1.37metre long perforated G.I. pipe.
Each
31.32 RECESSED CONDUIT PIPE WIRING SYSTEM WITH MODULAR
SWITCHES:
Wiring in P.V.C. insulated Fire Retardant copper conductor ISI
marked (Unsheathed) flexible multistrand cable to be laid in
heavy gauge welded conduit pipe 20mm/25mm dia (1.6mm
thick) ISI marked, recessed in wall etc., complete with powder
coated/anodized concealed metal boxes required for suitable
number of modules, for having electronic fan regulators, bell
push, electronic buzzer, 5pin 6Amp., 6pin 16/20Amp. Sockets
and 6/16/20Amp. Swithces (Screw Type Modular Accessories)
etc., and covered with Frame Plate etc., & including the cost of
required number of modular switches/ sockets, step type
electronic fan regulator 100watts, PVC connector (For Fan Box
and Electronic Buzzer), PVC Bush, Steel Hooks, Circular
Inspection Box (Recessed Type and Deep Type) conduit pipe &
copper wire and other Petty material etc. including the cost of
cutting and filling up of chases:-
1 2 3
III. Wiring call-bell point in 1.5mm² Copper conductor cable
with bell push and electronic buzzer 230 Volts AC
(including the cost of bell push, electronic buzzer &
powder coated concealed metal box for electronic
buzzer).
Each
IV. Wiring 5pin 6Amp. Wall socket (Shuttered) point in
1.5mm² copper conductor cable complete with bonding
to existing earth with 1mm² PVC insulated (Unsheathed)
flame retardant single core multistrand copper conductor
cable.
Each
V. Wiring 5pin 6Amp. Plug control comprising wall socket
(shuttered) and switch including bonding to existing earth
with 1mm² PVC insulated (Unsheathed) flame retardant
single core multistrand copper conductor cable.
Each
VI. Wiring 6pin 6/16/20Amp. Plug control comprising wall
socket (shuttered) and switch including bonding to
existing earth with 1mm² PVC insulated (Unsheathed)
flame retardant single core multistrand copper conductor
cable. Each
VII.Wiring light point in 1.5mm copper conductor cable with
2
1 2 3
III. Wiring call-bell point in 1.5mm² Copper conductor cable
with bell push and electronic buzzer 230 Volts AC
(including the cost of bell push, electronic buzzer &
powder coated concealed metal box for electronic
buzzer).
Each
IV. Wiring 5pin 6Amp. Wall socket (Shuttered) point in
1.5mm²copper conductor cable complete with bonding to
existing earth with 1mm² PVC insulated (Unsheathed)
flame retardant single core multistrand copper conductor
cable.
Each
V. Wiring 5pin 6Amp. Plug control comprising wall socket
(shuttered) and switch including bonding to existing earth
with 1mm² PVC insulated (Unsheathed) flame retardant
single core multistrand copper conductor cable.
Each
VI. Wiring 6pin 6/16/20Amp. Plug control comprising wall
socket (shuttered) and switch including bonding to
existing earth with 1mm² PVC insulated (Unsheathed)
flame retardant single core multistrand copper conductor
cable. Each
VII. Wiring light point in 1.5mm² copper conductor cable with
double control switches. Each
31.34 A SWITCH DISCONNECTOR FUSE UNIT (Without Sheet
Enclosure):
I. Supply and erection of 32Amp. 415volts, 50Hz. Double
Pole Switch Disconnector fuse unit with HRC Fuses
(Panel mounting Cubicle type) in the existing Cubical
Panel confirms to IS:13947 (PartI&III) complete with G.I.
Bolts, Nuts & Connection on both sides of switch with
sutiable size of Thimbles, including cost of HRC fuses
etc.
Each
II. Supply and erection of 63Amp. 415volts, 50Hz. Double
Pole Switch Disconnector fuse unit with HRC Fuses
(Panel mounting Cubicle type) in the existing Cubical
Panel confirms to IS:13947 (PartI&III) complete with G.I.
Bolts, Nuts & Connection on both sides of switch with
sutiable size of Thimbles, including cost of HRC fuses
etc.
Each
III. Supply and erection of 100Amp. 415volts, 50Hz. Double
Pole Switch Disconnector fuse unit with HRC Fuses
(Panel mounting Cubicle type) in the existing Cubical
Panel confirms to IS:13947 (PartI&III) complete with G.I.
Bolts, Nuts & Connection on both sides of switch with
sutiable size of Thimbles, including cost of HRC fuses
etc.
Each
31.34 IV. Supply and erection of 125Amp. 415volts, 50Hz. Double
Pole Switch Disconnector fuse unit with HRC Fuses
(Panel mounting Cubicle type) in the existing Cubical
Panel confirms to IS:13947 (PartI&III) complete with G.I.
Bolts, Nuts & Connection on both sides of switch with
sutiable size of Thimbles, including cost of HRC fuses
etc.
Each
1 2 3
V. Supply and erection of 32Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
VI. Supply and erection of 63Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
VII. Supply and erection of 100Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
VIII. Supply and erection of 125Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
IX. Supply and erection of 160Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
X. Supply and erection of 200Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
31.34 XI. Supply and erection of 250Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
1 2 3
XII. Supply and erection of 320Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
XIII. Supply and erection of 400Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
XIV. Supply and erection of 630Amp. 415volts, 50Hz. Triple
Pole and Neutral Switch Disconnector fuse unit with
HRC Fuses (Panel mounting Cubicle type) in the existing
Cubical Panel confirms to IS:13947 (PartI&III) complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles, including cost of
HRC fuses etc.
Each
31.34 B SWITCH DISCONNECTOR FUSE UNIT (With Sheet
Enclosure):
I. Supply and erection of 32Amp. 415volts, 50Hz. Double
Pole Switch Disconnector fuse unit with HRC Fuses in
sheet enclosure on the existing surface confirms to
IS:13947 (PartI&III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
existing earth and cost of HRC fuses etc.
Each
II. Supply and erection of 63Amp. 415volts, 50Hz. Double
Pole Switch Disconnector fuse unit with HRC Fuses in
sheet enclosure on the existing surface confirms to
IS:13947 (PartI&III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
existing earth and cost of HRC fuses etc.
Each
III. Supply and erection of 100Amp. 415volts, 50Hz. Double
Pole Switch Disconnector fuse unit with HRC Fuses in
sheet enclosure on the existing surface confirms to
IS:13947 (PartI&III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
existing earth and cost of HRC fuses etc.
Each
1 2 3
31.34 (B) IV. Supply and erection of 125Amp. 415volts, 50Hz. Double
Pole Switch Disconnector fuse unit with HRC Fuses in
sheet enclosure on the existing surface confirms to
IS:13947 (PartI&III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
existing earth and cost of HRC fuses etc.
Each
V. Supply and erection of 32Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
VI. Supply and erection of 63Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
VII. Supply and erection of 100Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
VIII. Supply and erection of 125Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
IX. Supply and erection of 160Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
1 2 3
31.34 (B) X. Supply and erection of 200Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
XI. Supply and erection of 250Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
XII. Supply and erection of 320Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
XIII. Supply and erection of 400Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
XIV. Supply and erection of 630Amp. 415volts, 50Hz. Triple
Pole & Neutral Switch Disconnector fuse unit with HRC
Fuses in sheet enclosure on the existing surface
confirms to IS:13947 (PartI&III) complete with G.I. Bolts
& Nuts/Rag Bolts & Nuts etc. according to the size of
holes in the body of enclosure and Connection on both
sides of switch with sutiable size of Thimbles including
bonding to existing earth and cost of HRC fuses etc.
Each
31.35 A ON LOAD CHANGEOVER SWITCH (Without Sheet
Enclosure)
I. Supply and erection of 125Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT (Panel mounting Cubical type) in the existing
Cubical Panel Confirms to IS:13947 (PartIII). complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles.
Each
1 2 3
II. Supply and erection of 160Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT (Panel mounting Cubical type) in the existing
Cubical Panel Confirms to IS:13947 (PartIII). complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles.
Each
31.35 (A) III. Supply and erection of 200Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT (Panel mounting Cubical type) in the existing
Cubical Panel Confirms to IS:13947 (PartIII). complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles.
Each
IV. Supply and erection of 250Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT (Panel mounting Cubical type) in the existing
Cubical Panel Confirms to IS:13947 (PartIII). complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles.
Each
V. Supply and erection of 320Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT (Panel mounting Cubical type) in the existing
Cubical Panel Confirms to IS:13947 (PartIII). complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles.
Each
VI. Supply and erection of 400Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT (Panel mounting Cubical type) in the existing
Cubical Panel Confirms to IS:13947 (PartIII). complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles.
Each
VII. Supply and erection of 630Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT (Panel mounting Cubical type) in the existing
Cubical Panel Confirms to IS:13947 (PartIII). complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles.
Each
VIII. Supply and erection of 800Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT (Panel mounting Cubical type) in the existing
Cubical Panel Confirms to IS:13947 (PartIII). complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles.
Each
IX. Supply and erection of 1000Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT (Panel mounting Cubical type) in the existing
Cubical Panel Confirms to IS:13947 (PartIII). complete
with G.I. Bolts, Nuts & Connection on both sides of
switch with sutiable size of Thimbles.
Each
31.35 B ON LOAD CHANGEOVER SWITCH (With Sheet
Enclosure):
1 2 3
I. Supply and erection of 125Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT in sheet enclosure on the existing surface confirms
to IS:13947 (Part III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
the existing earth.
Each
31.35 (B) II. Supply and erection of 160Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT in sheet enclosure on the existing surface confirms
to IS:13947 (Part III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
the existing earth.
Each
III. Supply and erection of 200Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT in sheet enclosure on the existing surface confirms
to IS:13947 (Part III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
the existing earth.
Each
IV. Supply and erection of 250Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT in sheet enclosure on the existing surface confirms
to IS:13947 (Part III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
the existing earth.
Each
V. Supply and erection of 320Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT in sheet enclosure on the existing surface confirms
to IS:13947 (Part III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
the existing earth.
Each
VI. Supply and erection of 400Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT in sheet enclosure on the existing surface confirms
to IS:13947 (Part III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
the existing earth.
Each
1 2 3
VII. Supply and erection of 630Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT in sheet enclosure on the existing surface confirms
to IS:13947 (Part III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
the existing earth.
Each
VIII. Supply and erection of 800Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT in sheet enclosure on the existing surface confirms
to IS:13947 (Part III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
the existing earth.
Each
31.35 (B) IX. Supply and erection of 1000Amp. 415Volts, 50Hz. Four
Pole On Load Change over Switch with advance neutral
UNIT in sheet enclosure on the existing surface confirms
to IS:13947 (Part III) complete with G.I. Bolts & Nuts/Rag
Bolts & Nuts etc. according to the size of holes in the
body of enclosure and Connection on both sides of
switch with sutiable size of Thimbles including bonding to
the existing earth.
Each
31.36 A MOULDED CASE CIRCUIT BREAKER:
(Fixed type thermal and Magnetic setting)
I. Supply and erection of 25-100Amp. 415volts Breaking
Capacity 16KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
II. Supply and erection of 125Amp. 415volts Breaking
Capacity 16KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
III. Supply and erection of 25-100Amp. 415volts Breaking
Capacity 25KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
IV. Supply and erection of 25-100Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
V. Supply and erection of 125Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
1 2 3
VI. Supply and erection of 160Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
VII. Supply and erection of 200Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
VIII. Supply and erection of 250Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
IX. Supply and erection of 25-100Amp. 415volts Breaking
Capacity 50KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
31.36A X. Supply and erection of 125Amp. 415volts Breaking
Capacity 50KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
XI. Supply and erection of 160Amp. 415volts Breaking
Capacity 50KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
XII. Supply and erection of 200Amp. 415volts Breaking
Capacity 50KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
XIII. Supply and erection of 250Amp. 415volts Breaking
Capacity 50KA Three Pole MCCB unit (Fixed type
thermal and Magnetic setting) (Panel mounting Cubical
type) in the existing Cubical Panel Confirms to
IEC:60947-II.
Each
31.36 B MOULDED CASE CIRCUIT BREAKER:
(Fixed Type Magnetic Setting & Adjustable thermal
setting)
I. Supply and erection of 25-100Amp. 415volts Breaking
Capacity 25KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
II. Supply and erection of 125Amp. 415volts Breaking
Capacity 25KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
1 2 3
III. Supply and erection of 160Amp. 415volts Breaking
Capacity 25KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
IV. Supply and erection of 200Amp. 415volts Breaking
Capacity 25KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
V. Supply and erection of 250Amp. 415volts Breaking
Capacity 25KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
VI. Supply and erection of 25-100Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
31.36 (B) VII. Supply and erection of 125Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
VIII. Supply and erection of 160Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
IX. Supply and erection of 200Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
X. Supply and erection of 250Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
XI. Supply and erection of 315-400Amp 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
XII. Supply and erection of 500-630Amp 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
1 2 3
XIII. Supply and erection of 800Amp. 415volts Breaking
Capacity 35KA Three Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
31.36 C MOULDED CASE CIRCUIT BREAKER:
(Fixed Type Magnetic Setting & Adjustable thermal
setting)
I. Supply and erection of 25-100Amp. 415volts Breaking
Capacity 25 KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
II. Supply and erection of 125Amp. 415volts Breaking
Capacity 25 KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
III. Supply and erection of 160Amp. 415volts Breaking
Capacity 25 KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
31.36 (C) IV. Supply and erection of 200Amp. 415volts Breaking
Capacity 25 KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
V. Supply and erection of 250Amp. 415volts Breaking
Capacity 25 KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
VI. Supply and erection of 25-100Amp. 415volts Breaking
Capacity 35KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
VII. Supply and erection of 125Amp. 415volts Breaking
Capacity 35KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
VIII. Supply and erection of 160Amp. 415volts Breaking
Capacity 35KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
IX. Supply and erection of 200Amp. 415volts Breaking
Capacity 35KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
1 2 3
X. Supply and erection of 250Amp. 415volts Breaking
Capacity 35KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
XI. Supply and erection of 315-400Amp.415volts Breaking
Capacity 35KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
XII. Supply and erection of 500-630Amp. 415volts Breaking
Capacity 35KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
XIII. Supply and erection of 800Amp. 415volts Breaking
Capacity 35KA Four Pole MCCB unit (Fixed Type
Magnetic Setting & Adjustable thermal setting) (Panel
mounting Cubical type) in the existing Cubical Panel
Confirms to IEC:60947-II.
Each
1 2 3
VI. Supply and Erction of Sheet Metal Double Door T.P. &
N. distribution Board (dust protected) provided with bus-
bar, neutral-link and din-bar, suitable for incorporating
S.P./S.P. & N Isolators or cubical switch for incoming &
single pole M.C.B's for outgoing 6way each including
bonding to existing earth.
Each
VII. Supply and Erction of Sheet Metal Double Door T.P. &
N. distribution Board (dust protected) provided with bus-
bar, neutral-link and din-bar, suitable for incorporating
S.P./S.P. & N Isolators or cubical switch for incoming &
single pole M.C.B's for outgoing 8way each including
bonding to existing earth.
Each
VIII. Supply and Erction of Sheet Metal Double Door T.P. &
N. distribution Board (dust protected) provided with bus-
bar, neutral-link and din-bar, suitable for incorporating
S.P./S.P. & N Isolators or cubical switch for incoming &
single pole M.C.B's for outgoing 12way each including
bonding to existing earth.
Each
IX. Supply and Erction of Sheet Metal Double Door T.P. &
N. (vertical design) distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating S.P./S.P. & N Isolators or cubical switch
for incoming & single pole M.C.B's for outgoing 4way
each including bonding to existing earth.
Each
31.37 X. Supply and Erction of Sheet Metal Double Door T.P. &
N. (vertical design) distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating S.P./S.P. & N Isolators or cubical switch
for incoming & single pole M.C.B's for outgoing 8way
each including bonding to existing earth.
Each
XI. Supply and Erction of Sheet Metal Double Door T.P. &
N. (vertical design) distribution Board (dust protected)
provided with bus-bar, neutral-link and din-bar, suitable
for incorporating S.P./S.P. & N Isolators or cubical switch
for incoming & single pole M.C.B's for outgoing 12way
each including bonding to existing earth.
Each
31.38 A RESIDUAL CURRENT CIRCUIT BREAKER:
I. Supply and Erection of Residual current circuit breaker
double pole 16/25Amp., Sensitivity 30mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
II. Supply and Erection of Residual current circuit breaker
double pole 32/40Amp., Sensitivity 30mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
III. Supply and Erection of Residual current circuit breaker
double pole 63Amp., Sensitivity 30mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
1 2 3
IV. Supply and Erection of Residual current circuit breaker
double pole 16/25Amp., Sensitivity 100/300mA, Suitable
for 240/415volts 50 cycles A.C. Supply, including
bonding to existing earth.
Each
V. Supply and Erection of Residual current circuit breaker
double pole 32/40Amp., Sensitivity 100/300mA, Suitable
for 240/415volts 50 cycles A.C. Supply, including
bonding to existing earth.
Each
VI. Supply and Erection of Residual current circuit breaker
double pole 63Amp., Sensitivity 100/300mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
VII. Supply and Erection of Residual current circuit breaker
four pole 16/25Amp., Sensitivity 30mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
VIII. Supply and Erection of Residual current circuit breaker
four pole 32/40Amp., Sensitivity 30mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
IX. Supply and Erection of Residual current circuit breaker
four pole 63Amp., Sensitivity 30mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
X. Supply and Erection of Residual current circuit breaker
four pole 16/25Amp., Sensitivity 100/300mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
31.38A XI. Supply and Erection of Residual current circuit breaker
four pole 32/40Amp., Sensitivity 100/300mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
XII. Supply and Erection of Residual current circuit breaker
four pole 63Amp., Sensitivity 100/300mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
31.38 B RCBO
I. Supply and Erection of RCBO (Earth Leakage, Overload
& Short Circuit Protection Device) double pole
16/25Amp. Sensitivity 30mA, Suitable for 240/415volts
50 cycles A.C. Supply, including bonding to existing
earth.
Each
II. Supply and Erection of RCBO (Earth Leakage, Overload
& Short Circuit Protection Device) double pole 32Amp.
Sensitivity 30mA, Suitable for 240/415volts 50 cycles
A.C. Supply, including bonding to existing earth.
Each
III. Supply and Erection of RCBO (Earth Leakage, Overload
& Short Circuit Protection Device) double pole 40Amp.
Sensitivity 30mA, Suitable for 240/415volts 50 cycles
A.C. Supply, including bonding to existing earth.
Each
1 2 3
IV. Supply and Erection of RCBO (Earth Leakage, Overload
& Short Circuit Protection Device) double pole 50Amp.
Sensitivity 30mA, Suitable for 240/415volts 50 cycles
A.C. Supply, including bonding to existing earth.
Each
V. Supply and Erection of RCBO (Earth Leakage, Overload
& Short Circuit Protection Device) double pole
16/25Amp. Sensitivity 100/300mA, Suitable for
240/415volts 50 cycles A.C. Supply, including bonding to
existing earth.
Each
VI. Supply and Erection of RCBO (Earth Leakage, Overload
& Short Circuit Protection Device) double pole 32Amp.
Sensitivity 100/300mA, Suitable for 240/415volts 50
cycles A.C. Supply, including bonding to existing earth.
Each
VII. Supply and Erection of RCBO (Earth Leakage, Overload
& Short Circuit Protection Device) double pole 40Amp.
Sensitivity 100/300mA, Suitable for 240/415volts 50
cycles A.C. Supply, including bonding to existing earth.
Each
VIII. Supply and Erection of RCBO (Earth Leakage, Overload
& Short Circuit Protection Device) double pole 50Amp.
Sensitivity 100/300mA, Suitable for 240/415volts 50
cycles A.C. Supply, including bonding to existing earth.
Each
31.39 EARTHING OF METALLIC CASES ETC. (COPPER EARTHING):
Each
II. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (20mm x 3mm) thick copper tape rivetted
to (30 cm x 120 cm x 3mm thick) tinned copper plate
(made cylindrical) burried 20metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc. , with
copper stapples of suitable size up to 23metre in length .
Each
III. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (20mm x 3mm) thick copper tape rivetted
to (30 cm x 120 cm x 3mm thick) tinned copper plate
(made cylindrical) burried 30metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc. , with
copper stapples of suitable size up to 33metre in length .
Each
1 2 3
IV. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (25mm x 3mm) thick copper tape rivetted
to (30 cm x 120 cm x 3mm thick) tinned copper plate
(made cylindrical) burried 10metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc. , with
copper stapples of suitable size up to 13metre in length .
Each
V. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (25mm x 3mm) thick copper tape rivetted
to (30 cm x 120 cm x 3mm thick) tinned copper plate
(made cylindrical) burried 20metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc. , with
copper stapples of suitable size up to 23metre in length .
Each
VI. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (25mm x 3mm) thick copper tape rivetted
to (30 cm x 120 cm x 3mm thick) tinned copper plate
(made cylindrical) burried 30metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc. , with
copper stapples of suitable size up to 33metre in length .
Each
31.39 VII. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (32mm x 3mm) thick copper tape rivetted
to (30 cm x 120 cm x 3mm thick) tinned copper plate
(made cylindrical) burried 10metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc. , with
copper stapples of suitable size up to 13metre in length.
Each
VIII. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (32mm x 3mm) thick copper tape rivetted
to (30 cm x 120 cm x 3mm thick) tinned copper plate
(made cylindrical) burried 20metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc. , with
copper stapples of suitable size up to 23metre in length.
Each
IX. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with (32mm x 3mm) thick copper tape rivetted
to (30 cm x 120 cm x 3mm thick) tinned copper plate
(made cylindrical) burried 30metre below ground level
and surrounded by salt & charcoal dust mixture including
fixing the copper tape on wall and in floor etc. , with
copper stapples of suitable size up to 33metre in length.
Each
1 2 3
X. Earthing of Sheet metal/ iron clad switches and metallic
cases etc., with 8SWG (4mm dia)copper wire run
through 15mm dia G.I. Pipe complete with connecting
the copper wire to (30cm x 60cm x 3mm thick) tinned
copper plate (made cylindrical) burried 10metre below
ground level and surrounded by salt & charcoal dust
mixture including fixing the G.I. Pipe on wall and floor
etc. upto 13 meter in length.
Each
Note :- Rates of item No. 31.32 to 31.39 are based on September 2008.
129.00
111.00
112.00
31.00
69.00
45.00
54.00
149.00
22.00
142.00
170.00
110.00
126.00
85.00
48.00
65.00
50.00
159.00
31.00
4
119.00
104.00
99.00
71.00
29.50
42.00
47.00
136.00
19.00
2.00
1.20
16.00
18.00
21.00
25.00
32.00
48.00
7.70
4
2.10
3.10
4.80
6.85
10.30
18.00
1.60
2.40
3.90
34.00
34.00
37.00
41.00
48.00
52.00
59.00
73.00
35.00
36.00
39.00
44.00
51.00
58.00
64.00
76.00
96.00
111.00
128.00
160.00
181.00
216.00
237.00
289.00
361.00
62.00
81.00
85.00
108.00
125.00
151.00
182.00
208.00
253.00
277.00
331.00
424.00
36.00
39.00
43.00
45.00
58.00
19.00
19.00
21.00
26.00
33.00
37.00
44.00
58.00
20.00
21.00
24.00
29.00
36.00
43.00
49.00
61.00
81.00
96.00
113.00
143.00
164.00
199.00
220.00
272.00
344.00
47.00
66.00
69.00
93.00
110.00
135.00
164.00
190.00
235.00
260.00
313.00
406.00
21.00
24.00
28.00
30.00
42.00
15.00
15.00
17.00
20.00
28.00
33.00
44.00
53.00
16.00
17.00
19.00
22.00
30.00
39.00
51.00
64.00
79.00
92.00
111.00
142.00
165.00
198.00
222.00
270.00
339.00
43.00
55.00
70.00
89.00
108.00
129.00
168.00
192.00
236.00
258.00
311.00
402.00
18.00
19.00
21.00
26.00
37.00
46.00
60.00
72.00
11.00
12.00
13.00
16.00
24.00
30.00
36.00
44.00
12.00
13.00
15.00
18.00
26.00
35.00
42.00
55.00
72.00
85.00
105.00
129.00
153.00
186.00
209.00
256.00
326.00
39.00
45.00
61.00
83.00
101.00
122.00
155.00
179.00
223.00
245.00
298.00
388.00
14.00
15.00
17.00
22.00
33.00
42.00
51.00
63.00
22.00
23.00
25.00
29.00
36.00
41.00
53.00
67.00
24.00
25.00
27.00
32.00
40.00
46.00
58.00
70.00
88.00
102.00
125.00
156.00
177.00
212.00
233.00
285.00
357.00
50.00
75.00
78.00
100.00
117.00
142.00
178.00
203.00
249.00
273.00
327.00
420.00
25.00
28.00
32.00
34.00
46.00
27.00
28.00
30.00
34.00
41.00
46.00
54.00
68.00
29.00
30.00
33.00
37.00
45.00
52.00
59.00
71.00
89.00
103.00
121.00
151.00
172.00
207.00
228.00
280.00
352.00
55.00
76.00
79.00
101.00
117.00
143.00
173.00
198.00
244.00
268.00
327.00
415.00
30.00
33.00
37.00
39.00
52.00
20.00
24.00
33.00
34.00
48.00
65.00
23.00
27.00
35.00
36.50
50.00
67.00
9.90
12.00
16.50
22.00
36.00
13.00
15.50
19.00
24.00
37.50
8.80
9.70
12.25
17.50
24.00
33.00
5.05
5.70
7.60
9.50
14.00
18.00
7.15
8.20
16.00
4
5.10
6.60
13.00
Category A
For Brands
Confirming to
I.S. Standard
(duly
approved)
60.00
116.00
140.00
119.00
148.00
294.00
473.00
859.00
146.00
195.00
390.00
689.00
1271.00
1565.00
2835.00
152.00
201.00
403.00
699.00
1290.00
1584.00
2886.00
126.00
160.00
335.00
834.00
1078.00
168.00
241.00
441.00
727.00
1183.00
1544.00
2266.00
2783.00
207.00
273.00
504.00
854.00
1246.00
1597.00
2424.00
2834.00
21219.00
29390.00
22028.00
31099.00
86.00
87.00
109.00
178.00
216.00
196.00
197.00
241.00
292.00
292.00
355.00
386.00
387.00
456.00
72.00
84.00
100.00
146.00
165.00
210.00
210.00
253.00
305.00
293.00
331.00
369.00
55.00
55.00
182.00
55.00
221.00
228.00
281.00
319.00
622.00
774.00
815.00
1018.00
635.00
828.00
1030.00
206.00
244.00
333.00
402.00
580.00
1903.00
158.00
266.00
355.00
274.00
324.00
406.00
590.00
691.00
349.00
475.00
614.00
828.00
1030.00
711.00
762.00
800.00
914.00
1123.00
776.00
839.00
943.00
1205.00
1345.00
2155.00
1133.00
1197.00
1288.00
1622.00
2267.00
2925.00
153.00
255.00
331.00
217.00
293.00
331.00
514.00
603.00
267.00
361.00
431.00
562.00
701.00
382.00
464.00
528.00
636.00
838.00
586.00
713.00
797.00
991.00
1162.00
1649.00
880.00
957.00
1073.00
1211.00
1407.00
1913.00
1092.00
1202.00
1372.00
48.00
1116.00
1326.00
1575.00
279.00
303.00
327.00
84.00
91.00
100.00
818.00
842.00
874.00
359.00
419.00
551.00
1309.00
4
879.00
1049.00
1258.00
1432.00
1508.00
1929.00
2560.00
3211.00
4212.00
516.00
583.00
790.00
1548.00
1873.00
42.00
57.00
68.00
351.00
409.00
476.00
568.00
548.00
778.00
695.00
977.00
110.00
134.00
4
180.00
217.00
261.00
107.00
112.00
115.00
126.00
114.00
122.00
141.00
148.00
151.00
158.00
172.00
165.00
181.00
199.00
142.00
156.00
175.00
219.00
241.00
265.00
296.00
407.00
522.00
631.00
704.00
1112.00
1914.00
202.00
226.00
275.00
318.00
364.00
198.00
201.00
207.00
218.00
206.00
220.00
234.00
241.00
244.00
259.00
274.00
268.00
284.00
299.00
240.00
255.00
276.00
322.00
347.00
374.00
405.00
519.00
23.00
27.00
24.00
27.00
29.00
33.00
125.00
357.00
363.00
417.00
330.00
1231.00
1353.00
1474.00
1.45
0.48
2.10
15.00
12.70
16.50
13.85
20.00
18.60
37.00
50.00
62.00
4.40
4.90
4.80
21.50
18.50
17.50
20.00
16.00
52.00
58.00
57.00
64.00
10.00
12.50
95.00
102.00
22.00
6.50
19.00
22.00
32.00
35.00
6.40
11.40
8.70
7.50
1.30
6.30
1.10
9.50
0.80
0.90
1.05
1.25
1.35
1.60
2.00
2.30
2.80
11.50
2.15
28.50
25.00
37.00
41.00
42.00
55.00
60.00
23.00
28.00
30.00
42.00
48.00
3.65
69.00
91.00
123.00
193.00
12.00
15.00
19.00
26.00
123.00
160.00
211.00
17.00
22.00
29.00
62.00
95.00
84.00
112.00
106.00
160.00
145.00
215.00
11.30
15.20
18.30
22.00
54.00
78.00
41.00
11.50
31.00
48.00
2.80
6.40
9.40
4.00
19.00
18.00
22.00
29.00
42.00
50.00
2.00
10.00
6.00
7.00
9.00
32.00
45.00
36.00
45.00
16.00
146.00
187.00
155.00
142.00
181.00
230.00
61.00
99.00
202.00
229.00
253.00
18.00
10.50
14.00
19.00
27.00
82.00
45.00
16.00
508.00
368.00
400.00
69.00
19.50
13.00
15.00
19.65
4.05
2.60
3.85
41.00
39.00
44.00
41.00
0.90
5.40
3.65
7.10
4.50
19.00
34.00
70.00
356.00
8.50
9.00
11.70
12.60
16.00
18.00
23.00
16.00
7.40
8.10
389.00
643.00
1008.00
781.00
872.00
1225.00
1443.00
1503.00
1582.00
735.00
827.00
1174.00
1381.00
1440.00
1520.00
226.00
318.00
501.00
5.80
9.15
136.00
31.00
190.00
160.00
82.00
136.00
35.00
24.00
20.50
17.00
113.00
35.00
16.50
133.00
43.00
4.60
34.00
48.00
80.00
12.50
8.00
4.50
42.00
1.80
37.00
153.00
98.00
91.00
18.00
28.00
10.20
11.50
14.00
18.00
6.10
4
7.40
14.00
17.00
21.00
23.50
30.50
60.00
99.00
137.00
25.00
4.55
9.60
111.00
203.00
990.00
1097.00
741.00
974.00
608.00
349.00
359.00
1120.00
722.00
803.00
505.00
737.00
467.00
322.00
350.00
814.00
1257.00
1773.00
3646.00
3784.00
1366.00
1998.00
3843.00
4333.00
3906.00
5828.00
6901.00
9173.00
11300.00
18306.00
1813.00
2221.00
4255.00
4397.00
2230.00
2877.00
5104.00
5567.00
6882.00
7430.00
8967.00
11280.00
13441.00
21552.00
6658.00
7236.00
8818.00
12488.00
13156.00
19159.00
22700.00
32567.00
53348.00
8865.00
10269.00
10996.00
15085.00
16074.00
23316.00
27266.00
38979.00
66532.00
2506.00
3664.00
2880.00
3872.00
4565.00
5421.00
6639.00
10120.00
5224.00
6100.00
6567.00
7499.00
11302.00
3112.00
3604.00
3788.00
4453.00
5050.00
3844.00
3964.00
5482.00
6588.00
10164.00
12368.00
15116.00
18894.00
4393.00
6042.00
6854.00
8669.00
10498.00
4427.00
5049.00
6810.00
9106.00
12309.00
16455.00
17741.00
24764.00
699.00
923.00
1204.00
1466.00
1835.00
2261.00
2800.00
3835.00
4222.00
5337.00
6818.00
1349.00
1422.00
1916.00
1312.00
1400.00
1835.00
1726.00
1748.00
1993.00
1661.00
1690.00
1946.00
1217.00
1275.00
1330.00
1630.00
1272.00
1338.00
1378.00
1711.00
9155.00
12337.00
15519.00
10012.00
13797.00
17582.00
11213.00
15844.00
20475.00
5001.00
08.
2 These Charges are for estimation purposes and not for hiring of private machinery from the market
for which competitive tenders/quotations shall be called and approval of the appropriate authority
obtained.
3 These charges are inclusive of all P.O.L. charges in case of item Nos. 32.1, 32.2, 32.7, 32.8, 32.9
& 32.10, but exclusive of these for other items for which the petrol and lubricants will be provided
by the user.
HORTICULTURE
Notes :-
(i) The rates given under this chapter are subject to the following conditions in addition to the
conditions laid down in the P.W.D. specifications.
(ii) Stacks of well decayed farm yard manure 32.5 cm in height, shall be measured and paid for 30 cm
height.
(iv) The rates noted below are applicable for gardening works in lawns of the buildings, road sides,
high slopes, canal embankments and arboriculture. The depth required to be excavated for
planting of trees/grass etc. shall be decided by the Engineer-in-charge with due difference to the
site and climatic conditions. The actual volume of excavated soil/earth shall be paid according to
the classification of soil. In case longer lead and lift is involved in the execution of a particular item,
additional rates shall be paid.
(v) The procurement of earth/sludge or manure shall be from the sources as specified by the
Engineer-in-charge. In case these are imported from a distant place longer than the ones specified
in the items additional rates shall be paid on the basis of cheapest mode of transport.
(vi) The cost of saplings/shrubs or grass etc., if specifically procured for planting shall be paid
separately
1 2 3
33.1 Supplying at site of work well decayed farm yard manure, from approved
source, including screening and stacking. Cum.
33.2 Turfing slopes of new banks with rough grassing including preparation of
ground, supplying and planting doob grass roots, at 15cm. apart
supplying and spreading manure at the rate 0.18 cum per 100 sqm. 100 Sqm.
33.3 Turfing slopes of old banks, with rough grassing including preparation of
ground, supplying and planting doob grass roots, at 15cm. apart,
supplying and spreading manure at the rate of 0.18 cum per 100 sqm
and loosening soil with kassi. 100 Sqm.
33.4 Making lawns including ploughing and dragging with sohaga breaking of
clods removal of earth rubbish dressing and supplying doob grass roots
and planting at 15 cm. apart including supplying of manure at the rate of
0.18 cum per 100 sqm & loosening soil with kassi. 100 Sqm.
33.6 Turfing lawns with fine grassing including ploughing, dressing including
breaking of clods removal of rubbish dressing and supplying of doob
grass roots at 10 cm apart including supplying and spreading of manure
at the rate of 0.60 cum per 100 sqm.
100 Sqm.
1 2 3
33.7 Maintenance of lawns with fine grassing for the first year including
watering etc. 100 Sqm.
33.8 Planting permanent hedges including digging of trenches 60cm wide and
45 cm. deep, refilling the excavated earth mixed with manure, supplied at
the rate of 4.65 Cum. Per 100 metres, and supplying and planting hedge
plants at 30cm. apart. 100 Metre
33.9 Maintaining the hedges for the first two years including watering etc.
complete. 100 Metre
33.10 Digging holes in all kinds of soil, and refilling the same with the excavated
earth, mixed with well decayed farm yard manure (Cost of well decayed
farm yard manure to be paid separately.)
(i) Hole 1.2 metres dia and 1.2 metres deep. Each
(ii) Hole 0.60 metres dia and 0.60 metres deep. Each
33.11 Edging with 2nd class bricks laid dry length wise, including excavation,
refilling, consolidating with hand packing and spreading neatly surplus
earth with a lead of 50 metres. per meter
33.12 Renovating lawns including weeding, cheeling the grass, forking the
ground, top dressing with forked soil, watering and maintaining the lawns
for 30 days or more, till the grass forms a thick lawn, free from weeds and
fit for moving and disposal of rubbish as directed including supplying
good earth if needed but excluding the cost of well decayed farm yard
manure.
100 Sqm.
33.13 Half brick circular tree Guard in 2nd class bricks internal dia. 1.25 metres
and height 1.2 metres above ground and 0.20 metres below ground
bottom two courses laid dry and top three courses in cement mortar (1:6)
1 cement and 6 sand and the intermediate courses being in dry/honey
comb masonry as per standard design complete. Each
33.14 Providing fixing M.S. plates iron/tree guard 60 cm. dia and 2 metres high
above ground level, formed of 4 Nos., 25mm. X 6mm and 6 No. 25mm x
3mm vertical M.S flats rivetted to 3 Nos. 25mm x 6mm M.S plates iron
rings in two halves bolted together with 8mm dia & 30mm long bolt
including painting two coats with paint of approved brand and
manufacture over a coat of priming complete in all respects.
Each
33.15 Making tree guard 53cm. dia, and 1.3 metre high as per design from
empty coal tar/Bitumen drums specified for by the department including
providing and fixing 2 Nos. M.S sheet rings 50mm x 0.5mm with rivets
complete in all respects including painting in side and out side.
(ii) Two or more coats of ready mixed paint of approved quality and
shade over a priming coat. Sqm.
1 2 3
33.16 Supplying and planting permanent trees including digging of earth pits
size 75 cm x 75 cm x 75cm deep refilling the excavated earth mixed with
manure supplied at the rate of 0.113 Cum. each and watering, supplying
through tractor tanker.
Each
(i) Maintenance of the tree for the Ist year including watering etc. Each
(ii) Maintenance of the tree for the 2nd year including watering etc. Each
(iii) Maintenance of the tree for the 3rd year including watering etc.
Each
(iv) Maintenance of the tree for 4th & 5th year including watering etc. Each
33.18 Planting permanent shrubs including digging of pits on earth size 0.60m x
0.60m.x 0.60m deep, refilling the excavated earth mixed with manure,
supplied at the rate of 0.056 Cum each and watering supply through the
tractor tanker. Each
33.19 Maintenance of shrub for one year including watering through tractor
tanker. Each
33.20 Supply and maintenance of thorny bush around the tree with manual
labour. Each
33.21 Planting selection No.1, Superior Quality grass with machinery including
ploughing the land leveling and dressing applying for made manure in
25mm layer, application of insecticide / pesticide to safeguard against soil
born insect/pests. Supplying and planting superior quality grass 7 to
10cm apart, weeding at 15 days interval for one month, top dressing with
soil, sand, FYM, mixture in 25mm layer over uneven surface 1:1:1 ratio.
Sqm.
33.22 Planting ground cover plants including digging and refilling of beds with
excavated soil and FYM, fertilizer and insecticides. Planting of sapling at
300mm distance of plant to plant and row to row, providing and fixing
brick tile edging.
Sqm.
33.23 Planting flower beds including digging and refilling of beds with
excavated soil and FYM fertilizer and insecticides planting of sapling at
300mm distance of plant to plant and row to row. Sqm.
33.24 Planting rose beds including digging and refilling of beds with excavated
soil and FYM fertilizer and insecticides planting of sapling at distance of
75 cm. plant to plant and row to row.
Sqm.
33.25 Creating earth mounds making desirable grade 1.20mtr. with plantation,
brick tiles and white stones including supply of earth, ground cover
plants, rare plants, supplying and fixing brick tiles for making boxes,
supplying white stone of average 15cm. size and fixing in position.
Sqm.
1 2 3
33.26 Planting ground cover (rare plants) including digging and refilling of beds
with excavated soil and FYM, fertilizer and insecticides, planting of
sapling at 300mm distance of plant to plant and row to row, providing
and fixing brick tile edging.
Sqm.
33.27 Planting rare & specimen plants including digging and refilling of beds
with excavated soil and FYM, fertilizer and insecticides, planting of
sapling in groups, providing and fixing brick tile edging. Each
33.28 Maintenance of ground cover plants for one year including 27 No.
waterings @ 4 waterings in the month of March, April, May and June, two
No. irrigations each in the month of February, October, November and
December and one irrigation each in July, August and September or as
per requirement of seasonal variations. 15 Nos. hoeings @ two hoeing
each in the month of July, Aug. & Sept. and one hoeing each in the
remaining 9 months, manuring with well rotten farmyard manure two
times in a year each time, providing and applying of fertilizers, plant
protection measures, training of plants and replacement of causalities.
Sqm.
33.29 Maintenance of flower beds for one year including 27 No. waterings @ 4
waterings in the month of March, April, May and June, two No. irrigations
each in the month of February, October, November and December and
one irrigation each in July, August and September or as per requirement
of seasonal variations. 15 Nos. hoeings @ two hoeing each in the month
of July, Aug. & Sept. and one hoeing each in the remaining 9 months,
manuring with well rotten farmyard manure two times in a year each time,
providing and applying of fertilizers, plant protection measures, training of
plants and replacement of causalities.
Sqm.
33.30 Maintenance of rose beds for one year including 27 No. waterings @ 4
waterings in the month of March, April, May and June, two No. irrigations
each in the month of February, October, November and December and
one irrigation each in July, August and September or as per requirement
of seasonal variations. 15 Nos. hoeings @ two hoeing each in the month
of July, Aug. & Sept. and one hoeing each in the remaining 9 months,
manuring with well rotten farmyard manure two times in a year each time,
providing and applying of fertilizers, plant protection measures, training of
plants and replacement of causalities.
Sqm.
33.31 Providing and fixing steel tree guards having 3 Nos. legs of angel iron
size 25x25x3mm 1.8 mtr. height, 3 Nos. rings of MS bars 8mm thickness
60 cm. dia and fixing of wire mesh size 3.81x7.62 cm. around the angel
iron name plate 200mmx25mmx18 gauge including painting 2 coat with
ISI marked ready mixed paint after one priming coat of metal primer.
Each
Note :- Rates of item No. 33.21 to 33.31 are based on September 2008.
Through
Rate
49.00
42.50
52.00
50.50
84.00
123.00
149.00
1084.00
506.00
10.30
1.65
2.75
93.00
125.00
277.00
29.00
44.50
21.50
48.00
40.00
37.00
32.00
13.50
35.50
8.30
35.00
146.00
110.00
127.00
554.00
231.00
655.00
65.00
219.00
63.00
1204.00
MISCELLANEOUS
(i) The rates given below are labour rates unless otherwise stated.
(ii) Unless otherwise stated, the labour rates include rehandling of materials within 100 metres.
1 2 3 4 5
34.1 Repairs to plaster in patches of area 2.5 sqm. and under including
cutting the patch in proper shape and preparing and plastering the
surface of the walls complete including disposal of rubbish to the
dumping ground within 50 metres lead :--
(a) for door chowkats (1.22 M. x 2.06 M.) Each 43.50 60.50
(b) for window chowkats (1.52 M. x 1.22 M.) Each 40.00 55.50
(c) for clerestorey window (1.22 M. x 0.46 M.) Each 37.00 45.00
1 2 3 4 5
34.4 Providing and fixing wooden cleats of size 100mm x 75mm x 50mm
to doors and windows with approved fittings including removal of
old cleats where necessary, including painting, polishing or bees
waxing to match the existing shade :--
(a) lst Class teak wood cleats with steel hinges and screws. Each 6.60 13.00
(b) lst Class deodar wood cleats with steel hinges and screws.
Each 6.40 11.00
(c) Sal wood cleats with steel hinges and screws. Each 6.40 12.00
(d) Ist class Kail wood cleats with steel hinges and screws. Each 6.40 11.00
34.5 Renewing glass panes with putty and nails wherever necessary :--
(c) Frosted glass panes weighing 7.5 Kg./Sqm. Sqm. 9.40 101.00
34.6 Renewing glass panes with wooden fillets wherever necessary :--
(c) Frosted glass panes weighing 8.44 Kg/sqm. Sqm. 11.80 84.00
(c) Frosted glass panes weighing 8.44 Kg/sqm. Sqm. 5.60 71.00
(a) Ist class teak wood fillets 3.20m x 0.0125m x 0.0125m Metre 1.50 3.40
(b) Ist class Deodar wood fillets 3.20m x 0.0125m x 0.0125m Metre 1.50 2.57
(c) Ist class Kail wood fillets 3.20m x 0.0125m x 0.0125m Metre 1.50 2.43
(a) Refixing old glass panes with putty and nails. Sqm. 7.00 34.00
(b) Fixing old glass panes with wooden fillets. Sqm. 5.80 --
1 2 3 4 5
34.10 Providing and fixing 16mm. M.S. fan clamps of standard shape and
size in existing R.C.C slab including cutting and making good and
painting exposed portion of the clamps complete. Each 23.00 28.00
34.12 Providing and fixing cotton string 6mm. diameter (Machine made)
including supplying and fixing, wherever necessary, the plate and
ring as per existing fitting or as required of the clerestorey window.
34.13 Renewing wooden battens roofs including making good the holes
in wall and painting with oil type wood preservative of approved
brand and manufacture complete including removal of rubbish to
the dumping ground within 50 metre lead.
34.14 Renewing wooden beams in roofs including making good the holes
in wall and painting with oil type wood preservative of approved
brand and manufacture complete including removal of rubbish to
the dumping ground within 50 metre lead.
1 2 3 4 5
34.15 Renewing 100mm dia. 2.5 metre long sal wood Ballies post
embedded 60cm in the ground in a hole 45cm. dia. and 70cm
deep, filled with cement concrete 1:5:10 (1 cement, 5 fine sand, 10
stone aggregate) (40 mm. nominal size) including necessary
excavation cement concrete foundation & painting two coats with
oil type wood preservative of approved brand and manufacture
complete, including disposal of rubbish to the dumping ground
within 50 metre lead.
Each 56.00 137.00
34.16 Raking out joints in lime or cement mortar and preparing the
surface for repointing or replastering including disposal of rubish to
the dumping ground within 50 metre lead (excluding the cost of
scraping of plaster and replastering). Sqm. 9.20 16.25
34.18 Flush pointing with cement sand mortar 1:3 (1cement, 3 fine sand),
mixed with 5% crude oil by weight of cement for flat tile bricks or
top of mud plaster.