Command 2G MML
Command 2G MML
STATUS/ALARM
o LIHAT STATUS HISTORY BCC MISSING ( NR=7767)...........
ZEOH::BCF=***,NR=7767;
o LIHAT STATUS BCF/TRAFFIC.... ZEEI:BCF=***;
o Reset ET.... ZUSC:ET,:BL/WO;
LIHAT ALARM BCF AKTIF....... ZEOL:***;
o CHECK SITE / TRAFFIC PER TIME SLOT.................... ZERO:BCF=***;
o LIHAT HISTORY ALARM BCF ZEOH:<YYYY-MM-DD>,:BCF=***:;
o LIHAT STATUS H/W (ET,BCSU) ZUSI:ET;
o CHECK ET DALAM 1 BSC... ZUSI:TCSM;
o CHECK ALARM ET AKTIF.................................. ZAHO:ET,***:;
o LIHAT HISTORY ALARM ET................................ ZAHP:ET,50:;
o CHECK STATUS N7....................................... ZNEL; ZNLI;
o CHECK ATR ............................................ ZRCI:SEA=3:CGR=1:PRINT=5;
o LIHAT ISI DALAM 1 ET.................................. ZDSB:::PCM=***;
o LIHAT JUMLAH CIRCUIT DALAM 1 BSC (IDLE/ BUSY)......... ZCEL:CGR=1;
o LIHAT JUMLAH CIRCUIT DALAM 1 BSC ( DETAIL )...........
ZCEL:CGR=1:CONN=BU,FORM=EXT;
o CHECK STATUS OM SIGNALING & TRX SIGNALING............. ZDTI:::PCM=et:
o CHANGE STATUS D CHANEL ( WO/BL/AD) OM & TRX...........
ZdtC:Dname\:WO/BL/AD;
o CHECK CRC PERFORMANCE................................. ZYMO:ET,***:CRC;
o CHECK OPC ( SEBAGAI SPC DI MSC )...................... ZNHI:;
LOCKED / UNLOCK
LOCKED/UNLOCKED BCF................................... ZEFS:***:L; / ZEFS:***:U;
o LOCKED/UNLOCKED BTS................................... ZEQS:BTS=***:L; /
ZEQS:BTS=***:U;
o LOCKED/UNLOCKED TRX................................... ZERS:BTS=***,TRX=***:L;
o ZERS:BTS=***,TRX=***,:U;
o TEST ET
...................................... ZUSC:ET,***:TE:; & ZUSC:ET,***:WO;
o LIST OUTPUT EXT INPUT &OUTPUT TEXT FOR ALARM
ZEFP;
o CREATE NEW TEXT....................................... ZEFE:TID=10:TEXT="SMOKE
ALARM";
o RESET BCF ( OMU/SITE)................................. ZEFR:***; // ( BCF ID )
o MELIHAT DIMANA BEKERJA................................ ZQNI;
o DIAGNOSIS ET.......................................... ZUDU:ET,***;
o CANCEL ET ALARM....................................... ZACA:***; // ( ALARM NBR)
o CREATE EXTERNAL ALARM.................................
ZEFX:xxx:INBR=16:POL=OPEN,ROU=ACT,:SEV=***(AL3),TID=***(INBR),:;
o AKTIF & non Aktifkan GPRS ........................................... ZEQV: BTS=xxx :
GENA=Y,RAC=x,CDEF=xxx , :NSEI= xxx :;
o AKTIF & non Aktifkan GPRS ........................................... ZEQV: BTS=xxx :
GENA=N,RAC=x,CDEF=xxx , :NSEI= xxx :;
o PARAMETER
o CHECK POWER SETTING .................................. ZEUO:BTS=***;
o HANDOVER PARAMETER.................................... ZEHO:BTS=***;
o CHECK BTS IDENTIFICATION PARAMETER.................... ZEQO:BTS=***;