The document contains commands used to monitor faulty transmission groups (TGs) and their alarms in a base station controller (BSC). It shows how to display all faulty TGs, alarms for a specific TG, the TG of a sector, and the E-1 status. It also contains commands to force and display the subordinate status of TG-149.

Uploaded by

ahmadalishah
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
89 views

Ericsson Basic Useful Commands

The document contains commands used to monitor faulty transmission groups (TGs) and their alarms in a base station controller (BSC). It shows how to display all faulty TGs, alarms for a specific TG, the TG of a sector, and the E-1 status. It also contains commands to force and display the subordinate status of TG-149.

Uploaded by

ahmadalishah
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

rxasp:moty=rxotg; // This command shows all the faulty TG's in BSC

rxasp:mo=rxotg-423;// This command shows alarms at a specific faulty TG


rxtcp:moty=rxotg,cell=hwy0039A // To find TG of a sector
rrscp:scgr=34; // To find E-1 status (WO= working operational)
RXBLI:MO=RXOTG-149, SUBORD, FORCE;
RXESE:MO=RXOTG-149,subord;
RXESI:MO=RXOTG-149,subord;
RXBLE:MO=RXOTG-149, SUBORD;