The document contains commands used to monitor faulty transmission groups (TGs) and their alarms in a base station controller (BSC). It shows how to display all faulty TGs, alarms for a specific TG, the TG of a sector, and the E-1 status. It also contains commands to force and display the subordinate status of TG-149.
Download as DOCX, PDF, TXT or read online on Scribd
100%(1)100% found this document useful (1 vote)
89 views
Ericsson Basic Useful Commands
The document contains commands used to monitor faulty transmission groups (TGs) and their alarms in a base station controller (BSC). It shows how to display all faulty TGs, alarms for a specific TG, the TG of a sector, and the E-1 status. It also contains commands to force and display the subordinate status of TG-149.
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1
rxasp:moty=rxotg; // This command shows all the faulty TG's in BSC
rxasp:mo=rxotg-423;// This command shows alarms at a specific faulty TG
rxtcp:moty=rxotg,cell=hwy0039A // To find TG of a sector rrscp:scgr=34; // To find E-1 status (WO= working operational) RXBLI:MO=RXOTG-149, SUBORD, FORCE; RXESE:MO=RXOTG-149,subord; RXESI:MO=RXOTG-149,subord; RXBLE:MO=RXOTG-149, SUBORD;