SOUNDPROOF DIESEL GENERATING SETS

DENYO POWER GENERATORS are


partners of our civil life
Denyo power generators are capable of generat-

ing power in various situations where public power


supply is not available.

They contribute to build

infrastructure of society and are highly appreciated


by customers all over the world.In a variety of situations like civil engineering works and construction
works to build infrastructure of our society.
Denyo engine power generators are capable of providing power at various sites where power is
required like civil work and construction sites as
well as are also employed in various facilities as
emergency power source for critical equipment like medical equipment in
hospital, bank online system and traffic signals etc.

As the power source in the areawhere electricity is


unavaiable.

As the power source in the construction site.

GENERAL CONSTRUCTION

The DCA Series generators are complete, stand alone generating


sets. All models consist of a Denyo alternator which is directly
coupled to a diesel engine. The alternator and engine are set on a
common skid base. Special vibration isolators are used to
minimise vibrations during operation.
The generator and electrical
components are fully enclosed
in a solid-steel,weatherproof
bonnet.
Noisesuppression is achieved

using highly effective sound


insulating materials.
1

As the Emergency power source in the hospital.

PERFORMANCE
FEATURES
HIGH-PERFORMANCE

The Denyo generating system


guarantees the following levels
of performance:
TEMPERATURE RISE : 100 temperature rise at 40 ambientJEC2130.
INSULATION : ClassFJEC2130.
VOLTAGE REGULATION : Within0.5%
except DCA-400SP, 400ES

FREQUENCY REGULATION: Within 5.0%


through noload to full-load.
VOLTAGE WAVEFORM : Deviation Factor
of open-circuit terminal voltage does not
exceed 0.06.
Telephone Influence FactorTIFis less
than 50.
ELECTROMAGNETIC INTERFERENCE
LEVEL : Attenuated to meet most commercial requirements.
INSULATION RESISTANCE : Higher than
3 Mega-ohms, measured between
a r m a t u r e w i n d i n g s a n d e a r t h, f i e l d
windings and earth, field control circuit
and earth.
The innovative excitation system* fitted
on all models, in conjunction with the AVR
and advance d br ushle s s ge ne rator,
p r ov i d e s f a s t vo l t a g e r e g u l a t i o n i n
response to load variations, enabling use
soon after start up. This system provides
output stability during load variations.
*U.S.Patent No.4268788

Synchronous brushless alternator for


minimal wear.
Designed to function in all climatic
conditions.

Will safely power the most sensitive


loads, such as thyristors, invertors and
computer systems, without the risk of
damage to these loads, thanks to the high
level electrical characteristics of the
generator's output.

ECONOMICAL
PERFORMANCE

Easy starting and quick response.


Utilising highly reliable diesel engines
with low fuel consumption, manufactured
by Japan's leading engine manufacturers.
Uninterrupted generator operation for up
to 12 hours under 75% load.

UNSURPASSED
FLEXIBILITY

To meet today's varying needs


successfully, your equipment
must be as flexible as you are.
The Denyo DCA Series generator range provides you with
the flexibilit y to get the job
done simply and economically,
without any delays.
TRUE HEAVY-DUTY PERFORMANCE
For a particular job, you may need that
extra power from your generator. With
the DCA Series, the standby power
rating110% or 105% load except DCA610SPMcan be used continuously for 1
hou r in eve r y 8 hou r s of c o ntinu ou s
operation.This ex tra power per formance of Denyo generators means you
can get the job done, without the
inconvenience of using another generator.

PARALLEL OPERATION FEATURE


( except for DCA-100 below )

From time to time, at a construction site,


mine site or in other situations, a large
temporary power supply is required for a
particular job. To meet this requirement
Denyo's DCA Series generators incorporate a built-in parallel operation drive
system, allowing you to create a largecapacity generating plant on-site, without
the need to procure any other equipment.
DUAL VOLTAGE SYSTEM
optional for DCA-25USI2, 45ESH, 45USI2, 60ESH,
60USH

F o r c o m p a n i e s t h a t o p e r a t e i n t e rnationally or have motors that require


power at different voltages, a different
generator is usually required for each
voltage setting. However, the DCA Series
ge ne r ator s a re e quipp e d with a dual
voltage system, so one generator can be
u s e d to p owe r m oto r s w i th di f fe re n t
voltage settings. An extremely convenient
feature.
ALL MODELS CAN RUN AT 50Hz/60Hz
Simply adjust the engine speed on the
control panel to use a DCA Series generator at either 50 Hz or 60 Hz.
EXTREMELY QUIET OPERATION
In urban areas and at the worksite, there is
an ever increasing demand for reduced
noise pollution. In response to these
concerns, Denyo has pioneered a
soundproof and super soundproof range of
generators. The DCA Series generators are
extremely quiet when operating at full load,
even though all soundproof models are
compactly designed. Check the
specifications for the sound level of each
model.

DENYO GENERATORS:
DESIGNED TO BE
TOTALLY
USER-FRIENDLY
MAINTENANCE MADE SIMPLER
A ll da ily m a inte na nc e re quire me nts c a n b e
performed from one side of the machine. The large
doors gives you full acces to the engine.
External drain plugs for oil, fuel and water are fitted
for convenience in performing routine maintenance.
Large fuel gauge is fitted for simple viewing.
For major engine overhauls, the bonnet can be
simply unbolted, which allows full access to the
engine.

FULLY APPOINTED CONTROL PANELS


FOR EASE OF USE AND MONITORING GENERATOR PERFORMANCE.
Tachometer
AC Ammeter
AC Volt me- ter
Pilot Lamp
Voltmeter Change-Over Switch
Panel Light
Synchroniziang Lamp
Single Parallel Change-Over Switch
Cir- cuit Breaker
Panel Light Switch
Ammeter Change-Over Switch

Voltage Regulator
Fre- quency Meter
Throttle Handle
Preheat Lamp
Battery Switch
Emergency Stop Button
Starter Switcr
Warning Lamp Unit
Charging Ammeter

Oil
Pressure Gauge

Water
temperature Gauge

TRANSPORTABILITY
The new designs of the DCA Series range have
achieved significant size and weight reductions over
previously producted models, through improvements in coupling techniques and alternator design.

T he s tu rd y we athe r p ro of s te e l b onnet o n a
heavy-duty steel skid base allows easy handling by a
forklift.

Provision of Various Protective Devices and


Warning Lamps
A circuit breaker is provided to protect the generator from
shorting of the load circuit or an overload.

The balance point lifting hook (lug) fitted on the


roof of each machine facilitates easy transportation
using a crane.

An emergency stop device is provided to automatically


detect an engine malfunction and shut down the unit, as well
as a warning lamp.

A l l m o d e l s a r e m o d u l a r d e s i g n e d , s o t h a t
generators can be stacked, thereby making the best
use of your valuable storage area.

Operation
Display

Engine Stop

Load Interrupt

Malfunction Display

Low oil pressure

High water temperature

Over-current

Electric leakage

Insufficient charging

Low fuel level

Plugging of air cleaner

Rise in fuel filter level

Over-speed

Item

O: Operates :Does not operate

1 Only for 13 to 35.Engine stopped/malfunction display not provided


for 25ESI,45 150ESH, US series.
2 Excluding 13 20LS,25ESK.
3 Only for 25ESI,45ESI,25USI2,45USI2.
4 Only for 60ESI2,600SPK,800SPK,800SPM,1100SPM,1100SPC.
5 Only for 60ESI2

SPECIFICATION TABLE13kVA45kVA CLASS SOUNDPROOF TYPE


DCA-13LSK DCA-13LSY DCA-15LSK DCA-20LSK DCA-25ESK DCA-25ESI DCA-35SPK DCA-45ESI DCA-45ESH
50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

10.5

13

10.5

13

12.5

15

17

20

20

25

20

25

30

35

37

45

37

45

11

13.7

11.5

14

13.8

16.5

18.7

22

22

27.5

22

27.5

31.5

36.75

38.9

47.3

38.9

47.3

60

3-Phase,4-Wire

or Single Voltage

or
Single Voltage
Single Voltage Dual VoltageDual Voltage is an option

Dual Voltage
0.8Lagging
Within 0.5
Brushless,Rotating Exciter
With A.V.R.
Class F

Yanmar
Kubota
3TNV84-G
D1403-K3A
Inlined,
Inlined,
Swirl Chambered Direct Injected

Class H

Class F

Isuzu
Isuzu
Kubota
Hino
BB-4JG1T
AA-4LE2
V3300-EB
W04D-K
Inlined,
Inlined,
Inlined,Direct Injected,
Inlined,
Inlined,Swirl Chambered
Direct Injected Swirl Chambered
Turbocharged
Direct Injected
13.7/1500 16.9/1800 15.3/1500 18.3/1800 16.9/1500 20/1800 21.5/1500 25.6/1800 25/1500 32.2/1800 26/1500 32/1800 38.5/1500 44.1/1800 46.5/1500 56/1800 46.5/1500 57/1800
Kubota
D1703-K3A

Kubota
V2203-K3A

Kubota
V2203-KB

10.2/1500 12.4/1800 11.3/1500 13.5/1800 12.4/1500 14.7/1800 15.8/1500 18.8/1800 18.4/1500 23.71800 19.1/1500 23.5/1800 28.3/1500 32.4/1800 34.2/1500 41.2/1800 34.2/1500 41.9/1800
3-8092.4
3-8490
4-8792.4
4-8596
3-8792.4
4-98110
4-8792.4
4-104118
4-95.4107
1.393

1.496

1.647

2.197

2.197

2.179

3.318

4.009

3.059

ASTM No. 2 Diesel Fuel or Equivalent


2.4

2.9

2.1

2.6

2.8

3.4

5.6

6.7

5.6

6.4

3.9

6.4

3.6

4.3

3.9

4.9

3.3

4.2

5.8

6.9

7.6

7.6

8.5

13.2

7.9

7.9

6.6

10.5

62

70

82

8.0
16.5
12.2

10.9

80D26R2
100

1390

1390

1390

1540

1540

1540

1900

1900

650

650

650

650

650

680

860

880

880

900

900

900

900

900

900

990

1250

1250

503

490

516

580

591

564

890

960

1180

58

6.5

7.8
10

95D31R1

80D26R1

1 Rated Voltage Classification

6.3

50Hz
60Hz
190220V
200240V
190220V
190240V
380440V
380480V
380440V
380480V
190220V
200240V
380440V380480V

61

61

62

60

63

64

61

62

64

60

64

60

63

60

62

2 Fuel consumption is based on operation at 75% load.


3 Sound level reflects high-speed no-load operation and is calculated by averaging the measurements at four points, each 7 meters from the source.
4 Depending on location and area,output voltage may differ from values listed in catalog.

indicates options.

DCA-13LSK

DCA-20LSK

DCA-15LSK

DCA-25ESI

DCA-45ESH

2000

59

61

SPECIFICATION TABLE60kVA150kVA CLASS SOUNDPROOF TYPE


DCA-60ESH DCA-60ESI2 DCA-75SPI DCA-100ESI DCA-125ESM DCA-125SPK3 DCA-150ESH DCA-150ESK DCA-150ESM
50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

65

75

80

100

100

125

100

125

125

150

125

150

125

150

55

66

55

66

68.3

78.8

88

110

138
110
110
3-Phase,4-Wire

138

138

165

138

165

138

165

Single Voltage
Dual Voltage is an option

Dual Voltage
0.8Lagging
Within 0.5
Brushless,Rotating Exciter
With A.V.R.

Class F

Class H

Class F

Hino
Komatsu
Mitsubishi
Isuzu
Mitsubishi
Komatsu
DD-6BG1T 6D16-TLE2D SA6D102E-1-A JO8C-UD SAA6D102E-2-D 6D16-TLE2D
Inlined,Direct Injected,
Inlined,Direct Injected, Turbocharged, Aftercooled
Turbocharged
66/1500 78/1800 65/1500 77/1800 80/1500 93/1800 100/1500 124/1800 145/1500 166/1800 133/1500 157/1800 153/1500 183/1800 153/1500 183/1800 153/1500 183/1800
Hino
Isuzu
BB-4BG1T
W04D-TG
Inlined,Direct Injected,
Turbocharged

Isuzu
A-6BG1
Inlined,Direct
Injected

48.5/1500 57.4/1800 47.9/1500 57.1/1800 58.8/1500 68.4/1800 73.6/1500 91.3/1800 107/1500 122/1800 97.8/1500 115.5/1800 113/1500 135/1800 113/1500 135/1800 113/1500 135/1800
6-114130
6-102120
6-118115
6-118115
6-102120
6-105125
4-104118
6-105125
4-105125
7.961
5.880
7.540
7.540
5.880
6.494
4.009
6.494
4.329
ASTM No. 2 Diesel Fuel or Equivalent
8.8

10.6

8.7

16.5

10.8

12.5

13.5

19.3

13.2

17.4

20.7

16.5

20.1

15.5

22.4

16

22

26.3

23.9

19.3

23.9

20.6

25.0

24.0

19.8

24.5

22

16

22.9

28.4

26

12.2

15.4

22.9

22.0

80D26R2

120E41R1

95E41R2

95D31R2

95E41R2

125

125

155

225

250

2050

2200

2630

2750

3280

3000

3200

3250

3350

880

880

1000

1050

1080

1080

1180

1080

1080

1250

1250

1300

1350

1500

1500

1500

1500

1500

1240

1120

1590

1730

2290

2120

2360

2390

2450

61
1 Rated Voltage Classification

11.0

50Hz
60Hz
190220V
190240V
380440V
380480V
190220V
200240V
380440V380480V

64

61

64

61

63

59

61

61

66

63

66

61

64

62

65

62

2 Fuel consumption is based on operation at 75% load.


3 Sound level reflects high-speed no-load operation and is calculated by averaging the measurements at four points, each 7 meters from the source.
4 Depending on location and area,output voltage may differ from values listed in catalog.

indicates options.

DCA-100ESI

DCA-60ESI2

DCA-150ESK

DCA-125SPK3

67

SPECIFICATION TABLE200kVA500kVA CLASS SOUNDPROOF TYPE

SPECIFICATION TABLE60kVA150kVA CLASS SOUNDPROOF TYPE

DCA-220ESM DCA-220SPK3 DCA-300SPK3 DCA-400ESM DCA-400SPK II DCA-500SPK DCA-500ESM

DCA-60ESH DCA-60ESI2 DCA-75SPI DCA-100ESI DCA-125ESM DCA-125SPK3 DCA-150ESH DCA-150ESK DCA-150ESM


50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

50

60

65

75

80

100

100

125

100

125

125

150

125

150

125

150

200

220

200

220

270

300

350

400

350

400

450

500

450

500

55

66

55

66

68.3

78.8

88

110

138
110
110
3-Phase,4-Wire

138

138

165

138

165

138

165

220

242

220

242

297

330

385

440

385

440

495

550

495

550

Single Voltage
Dual Voltage is an option

3-Phase,4-Wire

Dual Voltage
0.8Lagging

Dual Voltage
0.8Lagging

Within 0.5

Within 0.5

Within 1.0

Brushless,Rotating Exciter
With A.V.R.
Class F

Class H

Class F

Class F

Hino
Komatsu
Mitsubishi
Isuzu
Mitsubishi
Komatsu
DD-6BG1T 6D16-TLE2D SA6D102E-1-A JO8C-UD SAA6D102E-2-D 6D16-TLE2D
Inlined,Direct Injected,
Inlined,Direct Injected, Turbocharged, Aftercooled
Turbocharged
66/1500 78/1800 65/1500 77/1800 80/1500 93/1800 100/1500 124/1800 145/1500 166/1800 133/1500 157/1800 153/1500 183/1800 153/1500 183/1800 153/1500 183/1800

Komatsu
Mitsubishi
S6D125E-2-A
6D24-TLE2B
Inlined,Direct Injected, Inlined,Direct Injected,
Turbocharged
Turbocharged,Aftercooled

48.5/1500 57.4/1800 47.9/1500 57.1/1800 58.8/1500 68.4/1800 73.6/1500 91.3/1800 107/1500 122/1800 97.8/1500 115.5/1800 113/1500 135/1800 113/1500 135/1800 113/1500 135/1800
6-114130
6-102120
6-118115
6-118115
6-102120
6-105125
4-104118
6-105125
4-105125
7.961
5.880
7.540
7.540
5.880
6.494
4.009
6.494
4.329

181/1500 199/1800 178/1500 204/1800 232/1500 257/1800 309/1500 346/1800 310/1500 357/1800 382/1500 427/1800 382/1500 427/1800
6-130150
6-140165
6-135170
6-150175
6-170170
6-125150
11.940
15.240
14.600
18.560
23.150
11.040

Hino
Isuzu
BB-4BG1T
W04D-TG
Inlined,Direct Injected,
Turbocharged

Isuzu
A-6BG1
Inlined,Direct
Injected

Komatsu
SA6D125E-2-A

10.6

8.7

16.5

10.8

12.5

13.5

19.3

13.2

17.4

20.7

16.5

20.1

15.5

22.4

16

22

26.3

23.9

Komatsu
SA6D140-A

Komatsu
SA6D170-B

Mitsubishi
S6A3-E2PTAA-1

246/1500 270/1800 242/1500 277/1800 316/1500 350/1800 420/1500 470/1800 421/1500 485/1800 520/1500 580/1800 519/1500 581/1800

ASTM No. 2 Diesel Fuel or Equivalent

19.3

23.9

20.6

25.0

38.1

33.7

24.0

19.8

24.5

22

16

37

22.9

28.4

26

42

12.2

15.4

22.9

22.0

80D26R2

120E41R1

95E41R2

95D31R2

95E41R2

125

125

155

225

250

2050

2200

2630

2750

3280

3000

35.7

31.5

43.6

50.0

67.4

54.8

60.8

52.1

42

62

85

74

36

37

69.4

64

69.5

83.1

67.6

78.3

119

100

92.5

114.5

3
5480
5000

3
5280
4800

190H522

145G512
490

380

3200

3250

3350

3700

3650

3750

4500

4200

880

880

1000

1050

1080

1080

1180

1080

1080

1300

1300

1400

1400

1400

1650

1650

1250

1250

1300

1350

1500

1500

1500

1500

1500

1750

1750

1800

2100

2100

2400

2400

1240

1120

1590

1730

2290

2120

2360

2390

2450

3630

3670

4160

5610

5420

8540

7920

61

11.0

Mitsubishi
S6B3-E2PTAA-3

Inlined,Direct Injected,Turbocharged,Aftercooled

ASTM No. 2 Diesel Fuel or Equivalent


8.8

1 Rated Voltage Classification

Within 0.5

Brushless,Rotating Exciter
With A.V.R.

50Hz
60Hz
190220V
190240V
380440V
380480V
190220V
200240V
380440V380480V

64

61

64

61

63

59

61

61

66

63

66

61

64

62

65

62

67

61
1 Rated Voltage Classification

2 Fuel consumption is based on operation at 75% load.


3 Sound level reflects high-speed no-load operation and is calculated by averaging the measurements at four points, each 7 meters from the source.
4 Depending on location and area,output voltage may differ from values listed in catalog.

50Hz
190220V
380440V

60Hz
190240V
380480V

63

63

65

68

71

65

69

67

68

68

71

65

2 Fuel consumption is based on operation at 75% load.


3 Shown unit lengths are with visor.without visor
4 Sound level reflects high-speed no-load operation and is calculated by averaging the measurements at four points, each 7 meters from the source.
5 Depending on location and area,output voltage may differ from values listed in catalog.

indicates options.

indicates options.

DCA-220ESM

DCA-400ESM

DCA-100ESI

DCA-60ESI2

DCA-150ESK

DCA-125SPK3

DCA-400SPK II
5

DCA-500SPK
6

69

SPECIFICATION TABLE600kVA1100kVA CLASS SOUNDPROOF TYPE


DCA-600SPV DCA-600SPK DCA-610SPM DCA-800SPK DCA-800SPM DCA-1100SPM DCA-1100SPC
50

60

50

60

50

60

50

60

50

60

50

60

50

60

550

600

550

600

554

610

700

800

700

800

1000

1100

1000

1100

605

660

605

660

554

610

770

880

770

880

1100

1210

1100

1210

3-Phase,4-Wire

Dual Voltage

Single Voltage
0.8Lagging
Within 0.5

Brushless,Rotating Exciter
With A.V.R.
Class F

Class H

Komatsu
SA12V140

Komatsu
Mitsubishi
VOLVO
SA6D170A
S6R-PTA
TAD1642GE
Inlined Direct InjectedTurbocharged,Aftercooled

Mitsubish
S12H-PTA

Mitsubishi
S12A2-PTA

Cummins
QST30-G4

V12 Direct InjectedTurbocharged,Aftercooled

659/1500 723/1800 639/1500 698/1800 762/1500 768/1800 834/1500 1000/1800 830/1500 920/1800 1209.2/1500 1292.5/1800 1196/1500 1369/1800
485/1500 532/1800 470/1500 513/1800 517/1500 565/1800 613/1500 736/1800 610/1500 677/1800 890/1500 950/1800 880/1500 1007/1800
12-150175
12-140165
12-150160
6-170170
6-170180
6-144165
12-140165
37.110
30.480
33.93
23.150
24.500
16.120
30.48
ASTM No. 2 Diesel Fuel or Equivalent
81.2

91.7

93.7

81.8

93
48

82.0

96.4

102

120

103

125

119

92

151

120

112

118

170

205

190H522

154

180

154

244

234

190H524
800

490
3
51804700

3
5580
5100

3
5280
4800

3
6110
5500

3
6210
5600

3
6610
6000

3
6610
6000

1650

1650

1650

1950

1950

2350

2200

2400

2400

2400

2500

2500

2950

2790

7535

8860

8700

11200

11350

14500

12700

72
1 Rated Voltage Classification

50Hz
190220V
380440V
380440V

1[PS]=735.5[w]
=735.5[kw]

60Hz
190240V
380480V
380480V

75

67

71

69

72

70

72

67

69

72

74

2 Fuel consumption is based on operation at 75% load.


3 Shown unit lengths are with visor.without visor
4 Sound level reflects high-speed no-load operation and is calculated by averaging the measurements at four points, each 7 meters from the source.
5 Depending on location and area,output voltage may differ from values listed in catalog.

indicates options.

DCA-800SPM

DCA-600SPV

167

144

200

DCA-1100SPC

71

75

SPECIFICATION TABLE25kVA150kV CLASS SUPER SOUNDPROOF TYPE


DCA-25USI2 DCA-45USI2 DCA-60USH2 DCA-100USI DCA-125USH DCA-150USK
50

60

50

60

50

60

50

60

50

60

50

60

20

25

37

45

50

60

80

100

100

125

125

150

22

27.5

38.9

47.3

55

66

88

110

110

138

138

165

3-Phase,4-Wire
Single VoltageDual Voltage is an option.
0.8Lagging

Dual Voltage

Within 0.5
Brushless,Rotating Exciter
With A.V.R.
Class F

Isuzu
AA-4LE2

Isuzu
BB-4JG1T

Inlined,
Direct Injected

Hino
W04D-TG

Isuzu
DD-6BG1T

Hino
J08C-UP

Komatsu
SAA6D102E-2-D

Inlined,Direct Injected,
Turbocharged,Aftercooled
26/1500 32/1800 46.5/1500 56/1800 66/1500 78/1800 101/1500 126/1800 133/1500 156/1800 154/1500 184/1800
Inlined,Direct Injected,Turbocharged

19.1/1500 23.5/1800 34.2/1500 41.2/1800 48.5/1500 57.4/1800 74.5/1500 92.8/1800 97.8/1500 115/1800 113/1500 135/1800
4-8596

4-95.4107

2.179

3.059
3.9

3.2

6.7

2
4

60Hz
50Hz
190240V
190220V
380480V
380440V
200240V
190220V
380440V380480V

6-114130

6-102120

7.961

5.880

8.4

8.3

10.2

17.1

13.4

20.5

21.9

16.7

25.1

25.5

22

6.4

16.5
11.9

80D26R1
92

95D31R1
170

80D26R2
170

225

1400

1580

2050

2650

2950

3100

790

950

950

1100

1240

1240

1350

1550

1450

1500

1600

1600

773

1100

1330

1940

2400

2600

52
4

6-105125

4.009
6.494
ASTM No. 2 Diesel Fuel or Equivalent

10
10

8.5

1 Rated Voltage Classification

4-104118

52

51

53

22.4

19.6

20

55

52

22.4
95E41R2

95D31R2

55

250

57

53

56

55

2 Fuel consumption is based on operation at 75% load.


3 Sound level reflects high-speed no-load operation and is calculated by averaging the measurements at four points, each 7 meters from the source.
4 Depending on location and area,output voltage may differ from values listed in catalog.

indicates options.

DCA-45USI2

DCA-60USH2

NOTE 1 OUTPUT RATING

Continuous output rating applies to operation under standard conditions as per JIS D0006.
Standby output rating applies to intermittant or emergency operation for approximately 1 hour as per JIS D0006.
KilowattskWis calculated by multiplying output kVA by 0.8.
JIS D0006:Standard air conditions Tenperature 25 Atmospheric pressure 100kPa Relative humidity 319%RH

NOTE 2 RATED VOLTAGE

Line to neutral voltage is calcu- lated by dividing line to line voltage by 3.


Besides the voltages shown on the specification table, other voltages are available upon request.

NOTE 3
Colours of products would be different from printed ones of catalogues.

DCA-100USI

58

Options
Three-Phase/Single-Phase Output
Changeover Device

Remote Control Devices

The engine generator can be remotely changed from low speed to


high speed operation, started and stopped, and otherwise
controlled. The ability to perform these procedures automatically
or manually at the location where work is being performed when
the engine generator is separated by a considerable distance
p r ov i d e s h i g h f u e l a n d o i l s av i n g s , ex te n d s e n g i n e l i f e
substantially, and leads to a surprising level of reduction in
manpower and energy requirements. In addition, this also
minimizes noise and exhaust gas discharge levels, and in turn
helps improve the worksite environment.

For DCA-13LSK,13LSY,25ESK,25ESI,45ESH,45USI2,60ESH,60USH2

This device facilitates easy changeover between the three-phase


and single-phase output modes with the three-phase/singlephase changeover switch in the control panel. The control panel
has an output mode confirmation window and indicator lamp so
that the output mode can be confirmed at any time.
DCA-45USI2 and 60USH2 only provided with indicator lamp.

Parallel Operation Device

A variety of optional devices are available to change from manual


parallel operation to the desired type of automatic operation.
Select the desired option from the table below according to the
power supply application, site conditions and other factors.

Automatic Idling Device or Slowdown Device


Automatic Idling Device

For DCA-45 to 150, provided as standard feature for DCA-220 and above
Cannot be used with 45ESI, 45USI2

This device automates warm-up operation when the engine is


started. The addition of a remote-control box allows remote
changeover between low-speed and high-speed operation.
Please note that the engine cannot be started and stopped with
the remote-control box.
Slowdown Device

Operation

Engine
Starting /
Stopping

Synchronization
Verification/
Activation

Load
Sharing

Manual Parallel
Operation Device

Manual

Manual

Manual

Automatic Load
Sharing Device

Manual

Manual

Automatic

For DCA-150 and above

Automatic Parallel
Operation Device

Manual

Auto operation
with pushbutton

Automatic

For DCA-220 and above.


Standard feature for
DCA-1100SPM,1100SPC

Automatic

Automatic

Refer to 4 below for


applicable units.

Method

For DCA-45 to 150


Cannot be used with 45ESI,45USI2,60ESI2

In addition to a slowdown function that automatically


changes to high-speed operation when a load is applied,
and to low-speed operation when there is no load, this
device has an automatic idling function that performs
warm-up operation when the engine is startedbetween 5
and 180 seconds depending upon the room temperature
where the unit is located. Furthermore, the addition of a
remote-control box allows the engine starting/stopping and
automatic idling function as well as the slowdown function
to be operated from a remote location.
Remote ControllerFor DCA-220 to 1100
This device allows the engine starting/stopping
and automatic idling functionidling when
engine is startedto be operated from a remote
location. In addition to a switch for changeover
between high-speed and low-speed operation,
the remote-control box has a high-speed/low-speed operation
indicator lamp, a star tup warming lamp ( comes on when
generator set is not started up using normal remote controller
operation ) , and a malfunction indicator lampilluminated when
the emergency stop device is triggered.

Fully Automatic
Parallel Operation Semi-automatic
Device
Automatic
with GCP generator
controller

Remarks
Standard feature for
DCA-125 to 1100

1Manual Parallel Operation Device: Parallel operation system with unique


Denyo AVR equipped with a cross-current compensation circuitCCR system.
This is the most inexpensive system, where no addition equipment is required for
the DCA-125 and above.
2Automatic Load Sharing Device: This device operates a governor motor to
share the load uniformly among the respective generators when parallel
operation is being performed. It facilitates stable parallel operation, and
dramatically reduces the workload of monitoring during parallel operation.
3Automatic Parallel Operation Device: The troublesome synchronization
verification and synchronization activation process can be automatically
performed by simply pressing a pushbutton. After synchronization is activated,
the Automatic Load Sharing Device is capable of performing stable parallel
operation.
4Fully Automatic Parallel Operation Device: High-speed digital control enables
all operations from starting and stopping to synchronization verification,
synchronization activation and load sharing to be performed at the touch of one
button. This device has multiple functions that enable parallel operation of
generators with differing capacities, the number of units being operated to be
controlled and other operations.
Applicable models : DCA-220ESM, 400ESM, 500ESM, 610SPM, 800SPK,
provided as standard feature for DCA-800SPM.
5The generator may be classified as a normal use generator according to the
Electricity Enterprises Law depending upon the installation and operation
procedure. Consult with a sales person for details.

Note: The remote-control box for the DCA-800SPM differs from the picture.

Automatic Oil Lubrication Device

For DCA-25 to 800, provided as standard feature for DCA-500ESM, 610SPM,


800SPM and 1100SPM,1100SPC
Cannot be used with 25USI2,25ESK

Trailer

This system automatically maintains engine oil


at the proper level, making it possible to reduce
costs for oil-related maintenance, and eliminates the need to check the engine oil level.

Trailers can be fitted to generators to facilitate on-site movement.


trail-ers for DCA- 60 and below are two-wheel ;those for
DCA-75SP through 400 are four-wheel
Bolt connectors make mounting and dismounting simple.

Automatic Fuel Replenishment Device

For DCA-25ESI, 45 to 60

When the level in the unit tank drops after an extended period of
operation, a level sensor detects this and an electric pump is
operated to automatically replenish fuel in the unit tank from a
separate tank. Cannot be used with three-way valve.

Salt Corrosion Specifications

For DCA-13 to DCA-220, provided as standard feature for DCA-300 and above

These specifications are designed for when the unit will be used
on the coast or on the ocean, and include treatment to prevent
insulation resistance from dropping, and corrosion resistant
treatment of the parts.

Two-wheel type
Four-wheel type
9

Other Options

Lubricant temperature gauge


Provided as standard feature for DCA-220 and above

The following options are also available:

Overspeed protection device


Provided as standard feature for DCA-800SPK, 800SPM, 1100SPM,1100SPC

Reverse power relay


For DCA-125 and above.Provided as standard feature for DCA-800SPK,
800SPM,DCA-1100SPM,1100SPC

Keyed fuel tank cap


For DCA-13 to 1100

AC power meter
For DCA-125 and above.Provided as standard feature for DCA-800SPK,
800SPM,DCA-1100SPM,1100SPC

Mounting of muffler flange


Other options for different ranges and operating capabilities are available. Please feel
free to consult with Denyo.
* Some options may not be available depending upon the model. Confirm the details
with a Denyo sales person.

Dual-voltage specifications
For DCA-25USI2,45ESH,45USI2,60ESH,60USH2.Provided as standard feature
for DCA-25ESK,25ESI,45ESI,60ESI2,75SPI,DCA-100 to 800.Not available for
DCA-13LSK,13LSY,15LSK,20LSK,35SPK,DCA-1100SPM,1100SPC

HOW TO SELECT
A GENERATOR

Range of motor capacities that can be used with Denyo generators.


Choosing generator output according to motors and other loads is made simple by
referring to the motor capacity range and generator output in this table.
Item

Model

FrequencyHz
EG capacitykVA
Direct startup

DCA-15

DCA-13

DCA-20

DCA-25

DCA-35

DCA-45

DCA-60

50

60

50

60

50

60

50

60

50

60

50

60

50

10.5

13

12.5

15

17

20

20

25

30

35

37

45

50

60

3.4

4.1

5.4

6.3

6.3

7.6

9.4

11.6

12.3

14.9

16

20.5

60

Motor capacitykW Y- startup1

5.2

6.4

7.5

8.2

9.5

9.5

11.4

14.3

17.5

18.5

22.4

24

30.8

Y- startup2

8.3

10.2

9.6

11.9

13.1

15.7

15.7

19.5

23.1

27.7

28.2

34.3

38.4

46

Item

Model

DCA-75

DCA-100

DCA-125

DCA-150

DCA-220

DCA-300

DCA-400

FrequencyHz

50

60

50

60

50

60

50

60

50

60

50

60

50

60

EG capacitykVA

65

75

80

100

100

125

125

150

200

220

270

300

340

400

21.5

25

27.2

34.5

34.5

42.5

42.5

51

68

76

91

102

115

136

Motor capacitykW Y- startup1

32.3

37.5

40.8

51.8

51.8

63.8

63.8

76.5

102

114

136

153

173

204

Y- startup2

48.8

58

62

68

68

97

97

115

151

172

208

231

262

308

Direct startup

Item

Model

DCA-500

FrequencyHz

50

60

EG capacitykVA

450

500

Direct startup

DCA-600/610
50

60

550/554 600/610

DCA-800
50

60

700

800

155

175

185

205

210

243

Motor capacitykW Y- startup1

233

263

278

308

315

365

Y- startup2

351

390

432

460

508

575

Motor usage examples in the above table are benchmark values :


generator capacity will differ according to the required momentary
voltage drop, motor load factor, and size of startup capacity, as
well as motor age and efficiency.

Notes
Momentary voltage drop when a motor starts up is assumed to be within 30% of no- load voltage.
Motor startup kVA is assumed to be 7kVA per 1kW.
Motor efficiency is assumed to be 85%, and load factor about 90%.
Values shown for Y- startup1and Y- startup2are open and closed, respectively; needed generator capacity differs depending on startup state.
Not appropriate for determining the capacity of emergency generating equipmentespecially disaster-prevention generating equipment.

10

SOUNDPROOF DIESEL GENERATING SETS

MGMT. SYS.
RvA C 086

No.0263-ISO 9001

ISO 9001 Certified

The Denyo trademark is widely recognized as a brand , and is a registered trademark in 90 countries
aroud the world.
Direct inquiries to the nearest Denyo distributor or to Denyo co.,Ltd.

CAT.No.FG04-14-20110704-05