0% found this document useful (0 votes)
535 views1 page

Sizing Venturi Meter

This document specifies the design of a venturi flowmeter. It provides design data such as the duct dimensions, flowrate, temperatures and pressures. It includes calculations of parameters like density, flow area and velocity at different points in the venturi. Performance is shown at part loads from 10-100% flowrate. A diagram shows the venturi shape with converging and diverging sections and throat. Dimensions and angles are specified.

Uploaded by

hardik033
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
535 views1 page

Sizing Venturi Meter

This document specifies the design of a venturi flowmeter. It provides design data such as the duct dimensions, flowrate, temperatures and pressures. It includes calculations of parameters like density, flow area and velocity at different points in the venturi. Performance is shown at part loads from 10-100% flowrate. A diagram shows the venturi shape with converging and diverging sections and throat. Dimensions and angles are specified.

Uploaded by

hardik033
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

VENTURI

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60

Project
Client
Contractor
Item No.
Service
Location

FLOWMETER

SPECIFICATION

******
******
******

SHEET

Date
Sheet No.
Revision

2005. 11. 20.


1 of 1
0
1

Venturi Meter
Quantity
One(1)
set
GAH Downstream
DESIGN DATA
DIMENSIONS
Fluid Name
Combustion Air
Duct Width
mm
822
Condition
MCR
Duct Height
mm
1,200
Flowrate
Nm3/h
33,588
Angle, Converging
deg
30
Press., Inlet
mmH2O
500
Diverging
deg
30

Temp., Inlet
109
Relative Humidity
%
60
* Static Head Difference for
Density
kg/Nm3
#VALUE!
Throat Sizing
mmH2O
100
CALC U LATI O N S
* shall be 50 at max. flow.
Mass Flowrate
kg/h
#VALUE!
Pressure Drop
Density
kg/m3
#VALUE!
Vol. Flowrate
m3/h
#VALUE!
Inlet
mmH2O
#VALUE!
Inlet Flow Area
m2
0.9864
Converging Sec. mmH2O
#VALUE!
Inlet Velocity
m/sec
#VALUE!
Throat
mmH2O
#VALUE!
Velocity Head, 1/2V2/g
Diverging Sec.
mmH2O
#VALUE!
Inlet
mmH2O
#VALUE!
Total
mmH2O
#VALUE!
Throat
mmH2O
#VALUE!
Throat Velocity
m/sec
#VALUE!
Throat Flow Area
m2
#VALUE!
Pressure, Outlet
mmH2O
#VALUE!
Throat Width
mm
#VALUE!
P E R F O R M A N C E at P A R T L O A D
Load
Flowrate
Velocity, m/sec
Static H. Diff.
P. Drop, Total
%
Nm3/h
m3/h
Inlet
Throat
mmH2O
mmH2O
10
3358.8
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
20
6717.6
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
30
10076.4
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
40
13435.2
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
50
16794
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
60
20152.8
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
70
23511.6
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
80
26870.4
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
90
30229.2
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
100
33588
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
SKETCH :
Plan View
Flow

W = 822
H = 1200

5~15 mm
Inlet

750
a

Legend
D
Dh
w
d
dh
NTES

30

Convergent
Entrance Throat

###

30

Divergent Outlet

c
#VALUE! 220
#VALUE!
L1
L2
b
Venturi Length #VALUE!
#VALUE!

Equivalent Dia.
1121 * D = (4/WH)0.5
Hydraulic Dia.
976 * Dh = 4WH/(2(W+H))
Throat Width as required ( Height is same )
" Eq. Dia.
###
" Hyd. Dia.
###

1
2
a
b
c

10 ~ 40
deg
5 ~ 20
deg
~D
~w
= b/2
Narai Thermal Engineering Services

You might also like