This document describes various reference methods for installing electrical cables and conductors. It lists 16 different methods including: running insulated conductors in thermally insulated walls, installing multicore cables in conduit in thermally insulated walls, and placing insulated conductors in cable trunking on wooden or masonry walls either horizontally or vertically. The document provides brief descriptions and item numbers for each installation method.

Uploaded by

muhammad nazir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
106 views9 pages

Cable Sizing

This document describes various reference methods for installing electrical cables and conductors. It lists 16 different methods including: running insulated conductors in thermally insulated walls, installing multicore cables in conduit in thermally insulated walls, and placing insulated conductors in cable trunking on wooden or masonry walls either horizontally or vertically. The document provides brief descriptions and item numbers for each installation method.

Uploaded by

muhammad nazir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 9

Reference method

discription
non sheathed insulated conductors and single core cables in conduit in thermally insulated
wall with conductance not less than 10W/m2.K
multicore cables in conduit in a thermally insulated walls
multicore cables direct in a thermally insulated wall

insulated conductor /single core cables run in mouldings

insulated conductors/single core cables in conduit on a wooden/masonary


wall or spaced less than 0.3x conduit diameter from wall
Multicore cables in conduit on a wooden/masonary
wall or spaced less than 0.3x conduit diameter from wall
insulated condutors/single core cables in cable trunking on a wooden/masonary wall
run horizentally
insulated condutors/single core cables in cable trunking on a wooden/masonary wall
run vertically
multicore cables in cable trunking on a wooden/masonary wall
run horizentally

multicore cables in cable trunking on a wooden/masonary wall


run vertically

insulated condutors/single core cables in suspended cable trunking

multicore cables in suspended cable trunking

single core/multicore cables fixed directly under a wooden/masonary ceiling

single core/multicore cables in building voids

insulated conductors in conduit in a building void

single core/multicore cable in conduit in a building void

insulated conductors in cable ducting in building voids

single core/multicore cable in cable ducting in a building void

Insulated conductors in cable ducting in masonry having a thermal resistivity not


greater than 2 K m/W

Single-core or multi-core cable in cable ducting in masonry having a thermal resistivity not
greater than 2 K m/W

Single-core or multi-core cable in a ceiling void or raised floor

Insulated conductors or single-core cable in flush cable trunking in the floor

Multi-core cable in flush cable trunking in the floor

Insulated conductors or single-core cables in conduit in an unventilated cable channel run


horizontally or vertically

Insulated conductors in conduit in an open or ventilated cable channel in the floor

Sheathed single-core or multi-core cable in an open or ventilated cable channel run


horizontally or vertically

Insulated conductors or single-core cables in conduit in masonry

Multi-core cables in conduit in masonry

item#
1
2
3

12

4
5

10

11

21

40

41

42

43

44

45

46

47

50

51

54

55

56

59

60