0% found this document useful (0 votes)
60 views

Loading On Typical Roof Slab: Finish

The document provides loading specifications for various structural elements in a building including roof slabs, external and internal beams, staircases, balconies, and an overhead water tank. It specifies the slab thicknesses, material unit weights, dimensions of structural elements, and calculates the dead and live loads in KN/m2 or KN/m for each element. The total loading on the overhead water tank is calculated as 494.6 KN distributed across 5 supporting columns with a load of 98.9 KN on each column.
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views

Loading On Typical Roof Slab: Finish

The document provides loading specifications for various structural elements in a building including roof slabs, external and internal beams, staircases, balconies, and an overhead water tank. It specifies the slab thicknesses, material unit weights, dimensions of structural elements, and calculates the dead and live loads in KN/m2 or KN/m for each element. The total loading on the overhead water tank is calculated as 494.6 KN distributed across 5 supporting columns with a load of 98.9 KN on each column.
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 25

Loading on typical roof slab

Slab thickness =

100

Unit weight=

25 KN/m2

Self weight of slab =


Finish unit weight =
Plaster thickness =

1
25

KN/m2
mm
20 KN/m2

Plaster weight =

0.5 KN/m2

Partition wall unit weight=

Live load =

FINISH

2.5 KN/m2

Plaster unit weight =

Total dead load per square metre=


Type of building =
SUBTYPE=

mm

1 KN/m2
5
RESIDENTIAL_BUILDINGS
FLATS

KN/m2

KN/m2

PLASTER

SL

SLAB

Loading on terrace roof slab


Slab thickness =

100

mm

Unit weight=

25

KN/m2

Self weight of slab =

2.5

KN/m2

Finish unit weight =


Plaster thickness =

1
25

KN/m2
mm

Plaster unit weight =

20

KN/m2

0.50

KN/m2

KN/m2

6
RESIDENTIAL BUILDINGS

KN/m2

1.5

KN/m2

Plaster weight =
Water proofing weight =
Total dead load per square metre=
Type of building:
Live load =

FINISH

PLASTER

WATER PROOFING

SLAB

Loading on stair room roof slab


Slab thickness =

100

mm

Unit weight=

25

KN/m2

Self weight of slab =

2.5

KN/m2

Finish unit weight =


Plaster thickness =

1
25

KN/m2
mm

Plaster unit weight =

20

KN/m2

0.50

KN/m2

KN/m2

6
RESIDENTIAL_BUILDINGS

KN/m2

0.75

KN/m2

Plaster weight =
Water proofing weight =
Total dead load per square metre=
Type of building
Live load =

FINISH

PLASTER

WATER PROOFING

SLAB

Loading on balconies
Slab thickness =

100

mm

Unit weight=

25

KN/m2

Self weight of slab =

2.5

KN/m2

Finish unit weight =


Plaster thickness =

1
25

KN/m2
mm

Plaster unit weight =

20

KN/m2

0.50

KN/m2

KN/m2

Plaster weight =
Water proofing weight =
Total dead load per square metre=
Type of building:
Live load =

6
KN/m2
RESIDENTIAL_BUILDINGS
HOTELS
4

KN/m2

Loading on external beam


External wall thickness =
Plaster thickness =
External wall height =
Unit weight wall =
Unit weight plaster =
Load of external wall =

200
25
0.85

mm
mm
m

20

KN/m2

20
3.825

KN/m2
KN/m

Loading on internal beam


Internal wall thickness =
Plaster thickness =
Internal wall height =

125
25
1.45

Unit weight of brick wall=

20

KN/m2

20
4.35

KN/m2
KN/m

Unit weight of plaster =


Load of internal wall =

mm
mm
m

STAIRCASE
LOADING DUE TO LANDING 1
DEPTH OF LANDING = dl1 =
WIDTH OF LANDING = wl1=

125 mm
1.2 m

DEPTH OF FINISH = fl1 =

12 mm

DEPTH OF PLASTER = pl1 =

12 mm

UNIT LOAD OF RCC =


LOAD DUE TO LANDING SLAB =
UNIT LOAD OF FINISH =
LOAD DUE TO FINISH =

25 KN/m2
3.750 KN/m
24 KN/m2
0.3456 KN/m

UNIT LOAD OF PLASTER =


LOAD DUE TO PLASTER =

20 KN/m2
0.288 KN/m

TOTAL LOAD PER METRE OF LANDING 1 =

4.384 KN/m

LOADING DUE TO LANDING 2


DEPTH OF LANDING = dl2 =

125 mm

WIDTH OF LANDING = wl2=

0m

DEPTH OF FINISH = fl2 =

12 mm

DEPTH OF PLASTER = pl2 =

12 mm

UNIT LOAD OF RCC =


LOAD DUE TO LANDING SLAB =

25 KN/m2
0 KN/m

UNIT LOAD OF FINISH =


LOAD DUE TO FINISH =

24 KN/m2
0 KN/m

UNIT LOAD OF PLASTER =


LOAD DUE TO PLASTER =
TOTAL LOAD PER METRE OF LANDING 2 =

20 KN/m2
0.000 KN/m
0 KN/m

LOADING DUE TO STAIRCASE


LOADING DUE TO STEPS:
TREAD = T =
RISE = R =
VOLUME OF STEPS = 1/2X(RT) =
UNIT WEIGHT OF STEPS =
LOAD DUE TO EACH STEP =
NUMBER OF STEPS =

250 mm
150 mm
0.01875 m2/m
24 KN/m2
0.45 KN/m
21

FINISH

PLASTER
WAIST SLAB DEPTH

RISER

TOTAL LOAD DUE TO STEPS =

9.450 KN/m

LOAD DUE TO FINISH:


DEPTH OF FINISH = F =
UNIT WEIGHT OF FINISH =
LOAD DUE TO FINISH =

FINISH

TREAD

SLAB DEPTH

15 mm
23.5 KN/m2
7.4025 KN/m

LOAD DUE TO WAIST SLAB:


DEPTH OF WAIST SLAB = w =
LENGTH OF WAIST SLAB PER STEP = (R2 + T2)0,5 =
TOTAL LENGTH OF WAIST SLAB =
DEPTH OF PLASTER =

125 mm

FIRST LANDING

SPAN

SECOND LANDING

0.291548 m
6.122499 m
15 mm

UNIT LOAD OF PLASTER =

20 KN/m2

UNIT LOAD OF RCC =

25 KN/m2

TOTAL DEAD LOAD DUE TO STAIRCASE


TYPE OF BUILDING =
SUBTYPE=

LOAD DUE TO WAIST SLAB =


LOAD DUE TO PLASTER =

19.133 KN/m
1.837 KN/m

LIVE LOAD =
LIVE LOAD PER METRE SPAN =

FINISH

PLASTER
WAIST SLAB DEPTH

SER

TREAD

SPAN

SECOND LANDING

UE TO STAIRCASE

37.822 KN/m
RESIDENTIAL_BUILDINGS
FLATS

RE SPAN =

3 KN/m2
19.350 KN/m

TYPE OF BUILDING
RESIDENTIAL_BUILDINGS
EDUCATIONAL_BUILDINGS
INSTITUTIONAL_BUILDINGS
ASSEMBLY_BUILDINGS
BUSINESS_AND_OFFICE_BUILDINGS
MERCANTILE_BUILDINGS
INDUSTRIAL_BUILDINGS
STORAGE_BUILDINGS

TYPE OF BUILDING
COLD_STORAGES
DIAGNOSTIC_CENTRE
FLATS
FUNCTION_HALLS
HOSPITALS
HOTELS
LIBRARIES
LOW COST HOUSING
RESTAURANTS
RETAIL_SHOPS
SCHOOLS
VAULTS
WARE_HOUSES
WHOLESALE_SHOPS
WITH_FIXED_COMPUTERS
WITH_HEAVY_DUTY_MACINERY
WITH_LIGHT_DUTY_MACINERY
WITH_MEDIUM_DUTY_MACINERY
WITHOUT_FIXED_COMPUTERS
WITHOUT_MACHINERY

RESIDENTIAL_BUILDINGS
LOW COST HOUSING
FLATS
HOTELS

ROOMS BALCONIES
15
3
2
5
2
2
6
1.5
4
4
3
5
7.5
6
3.5
10
5
7
3
2.5

4
4
3
4
4
4
4
3
4
4
4
4
4
4
4
4
4
4
4
4

EDUCATIONAL_BUILDINGS
SCHOOLS
LIBRARIES

STAIRCASE
5
4
3
5
4
3
4
1.5
5
5
4
4
5
5
4
5
5
5
4
5

SCHOOLS
3

INSTITUTIONAL_BUILDINGS
HOSPITALS
DIAGNOSTIC_CENTRE

ASSEMBLY_BUILDINGS
FUNCTION_HALLS
RESTAURANTS

BUSINESS_AND_OFFICE_BUILDINGS
WITH_FIXED_COMPUTERS
WITHOUT_FIXED_COMPUTERS
VAULTS

MERCANTILE_BUILDINGS
RETAIL_SHOPS
WHOLESALE_SHOPS

INDUSTRIAL_BUILDINGS
WITHOUT_MACHINERY
WITH_LIGHT_DUTY_MACINERY
WITH_MEDIUM_DUTY_MACINERY
WITH_HEAVY_DUTY_MACINERY

STORAGE_BUILDINGS
WARE_HOUSES
COLD_STORAGES

OVER HEAD TANK LOAD


LENGTH OF TANK = L
BREDTH OF TANK = B
HEIGHT OF TANK= H

4.85
3.85
1.2

m
m
m

TANK SLAB BOTTOM THICKNESS= Dbot

200

mm

TANK SLAB TOP THICKNESS = Dtop

100

mm

DTOP
WTH

DBOT

WALL THICKNESS = Wth


LOAD DUE BOTTOM SLAB = LXBXDBOTX25
LOAD DUE TO TOP SLAB = LXBXDTOPX25

250

OVERHEAD TANK SECTIONAL ELEVATION

mm

93.3625 KN
46.68125 KN
B

LOAD DUE TO TANK WALLS = 2X(L+B)XHXWthX25


LOAD DUE TO WATER = LXBXHX10
TOTAL LOAD DUE TO OVER HEAD TANK =
NUMBER OF COLUMNS SUPPORTING THE TANK =
LOAD ON EACH COLUMN =

130.5

KN

224.07

KN

494.6138 KN
5
98.92275 KN

L
OVERHEAD TANKPLAN

DTOP

DBOT

D TANK SECTIONAL ELEVATION

L
OVERHEAD TANKPLAN