pH
Resolution selectable from 0.01
and 0.001 pH
Range -2.00016.000 pH
Accuracy 0.002 pH
Data logging
Manual log on demand
Manual log on stability
Interval logging
Temperature readout (C or F)
Automatic Temperature Compensation
CAL-CHECK Indicators:
Probe condition
Response time
Check buffer
Clean electrode
Sensor Check Indicators:
Broken electrode
Clogged junction
GLP data
Records date, time, offset, slope and buffers
used during calibration
5 point calibration
A choice of 7 pre-programmed buffers plus 2
selectable custom buffers
Calibration tag on screen
- Identifies buffers used for current calibration
Calibration expiration warning
Conductivity
Four ring potentiometric probe
Covers all ranges from 0.00 S/cm to
500 mS/cm (absolute EC)
Dissolved Oxygen
Clark type polarographic probe with
replacement membrane cap
Ranges:
Accuracy
Calibration
Offset (0 S/cm) and cell factor calibration
Choice of 5 standards
Auto-ranging or manual range selection
EC, TDS, and Salinity reading modes
Temperature compensation
Automatic
NoTC (absolute)
GLP data
Records date, time, offset, and cell constant
value (K)
Adjustable EC to TDS conversion factor
Adjustable temperature correction
coefficient
footprint
inch thick
oz. weight
inch display
USB ports
edge pH EC DO
Two USB Ports
Hanna Instruments is proud to introduce the worlds most
innovative pH meter... edge.
edge is thin and lightweight, measuring just 12 thick and
weighing less than 9 ounces. edge has an incredibly wide
viewing angle, 5.5 LCD and a sensitive capacitive touch keypad.
edge measures pH, conductivity and dissolved oxygen through
its unique digital electrodes. These digital electrodes are autorecognized. Providing sensor type, calibration data and a serial
number, and they connect to edge with an easy to plug-in
3.5mm connector. edges versatile design is equally at home in
your hand, on a lab bench or mounted on a wall. edge simplifies
measurement, configuration, calibration, diagnostics, logging
and transferring data to a computer or a USB drive.
edge features Hannas exclusive CAL-CHECK to warn
you if the electrode you are using is not clean or if your buffers
are contaminated during calibration. We have also added to
CAL-CHECK for sensors with matching pin: now it warns you if
the pH bulb is cracked, and if the junction of the electrode
is compromised.
edge is the culmination of Hannas vision, design capabilities,
integrated production facilities, and world class R&D teams.
With edge, Hanna has set the new standard!
5.5"
Great Design
Basic mode
You can use edge in Basic Mode,
ideally for routine measurements
for a simplified screen and
features.
GLP
CAL-CHECK
edge features Hannas exclusive
CAL-CHECK to warn you if the bulb
of the electrode is not clean or if the
buffers are contaminated during
calibration.
Zero Footprint
Using the wall mount cradle (included), edge
can be placed on a wall, leaving zero footprint
on the benchtop space. The cradle has a built
in connector to power edge and charge its
batteries. edge's zero footprint is designed to
save you valuable benchtop space.
Data Logging
edge allows you to store up to 1000
log records of data. Data sets include
readings, GLP data, date and time.
Technical Specifications
Specifications
pH
EC
DO
Temperature
Additional
Specifications
Range
Resolution
Basic: 0.1 mV
Standard: 0.01 pH; 0.001 pH
Accuracy (@25C/77F)
Calibration Points
Calibration Buffers
standard mode: 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 and two custom buffers
basic mode: 4.01, 6.86, 7.01, 9.18, 10.01
Temperature Compensation
Electrode Diagnostics
Standard: probe condition, response time and out of calibration range, glass and reference junction diagnostics ( HI
11311 & HI 12301 only)
EC
TDS
Range
Resolution
Accuracy (@25C/77F)
1% of reading
Calibration
through EC calibration
Temperature Compensation
TDS Factor
0.40 to 0.80
Range
Resolution
Accuracy
Calibration Points
one or two points at 0% (HI 7040 solution) and 100% (in air)
Temperature Compensation
Salinity Compensation
Altitude Compensation
Range
Resolution
0.1C; 0.1F
Accuracy
0.5C; 0.9 F
Logging
stores up to 1000 records: 200 records (log-on-demand and stability logging); 600 records interval logging
Connectivity
1 USB port for storage; 1 micro USB port for charging and PC connectivity
pH Electrode (included)
HI 11310 glass body pH electrode with 1/8(3.5mm) connector and 1 m (3.3) cable
Environment
Power Supply
Dimensions
Weight
Salinity
Ordering Information
Electrodes
Wall-mount cradle
USB cable
2 sachets of
pH 4 buffer solutions
2 sachets of
pH 7 buffer solutions
2 sachets of
pH 10 buffer solutions
Electrode cleaning
solutions
HI 11311
Single ceramic, double junction,
refillable pH electrode with
temperature sensor and matching pin
HI 12300
Double junction, gel filled,
PEI body, pH electrode with
temperature sensor
HI 12301
Double junction, gel filled, PEI body,
pH electrode with temperature
sensor and matching pin
HI 10530
Triple ceramic, single junction,
low temperature glass, refillable
pH electrode with conical tip and
temperature sensor
HI 10430
Single ceramic,double junction,
high temperature glass, refillable
pH electrode with double junction
Instruction manual
HI 11310
Glass body, refillable
pH electrode with
temperature sensor
HI 11310
Single ceramic, double junction,
refillable pH electrode with
temperature sensor
Quality certificate
HI 763100
Conductivity probe
3 sachets of
1413 S/cm
conductivity standard
3 sachets of
12880 S/cm
conductivity standard
HI 763100
Conductivity eletrode with
temperature sensor
HI 764080
Dissolved Oxygen electrode with
temperature sensor
Recommended for
general purpose
Recommended for
general purpose
Quality certificate
HI 764080
Dissolved Oxygen
electrode
HI 7041S
Refill electrolyte
solution
2 DO membrane caps
2 DO membrane cap
o-rings
Quality certificate