0% found this document useful (0 votes)
371 views4 pages

Mathcad - Punching Shear

This document summarizes the check of punching shear for the reaction of a pile cap and column. For the pile cap, the maximum punching shear force was calculated to be 53.23 tonnes. The nominal shear strength provided by the concrete was calculated to be 2232.31 kN, which exceeds the required shear strength of 696.04 kN. For the column, the required punching shear strength was calculated to be 703.07 kN. The nominal shear strength provided by the concrete was calculated to be 2227.72 kN, exceeding the required strength. Both the pile cap and column pass the punching shear check.

Uploaded by

Ma'rruf Amar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
371 views4 pages

Mathcad - Punching Shear

This document summarizes the check of punching shear for the reaction of a pile cap and column. For the pile cap, the maximum punching shear force was calculated to be 53.23 tonnes. The nominal shear strength provided by the concrete was calculated to be 2232.31 kN, which exceeds the required shear strength of 696.04 kN. For the column, the required punching shear strength was calculated to be 703.07 kN. The nominal shear strength provided by the concrete was calculated to be 2227.72 kN, exceeding the required strength. Both the pile cap and column pass the punching shear check.

Uploaded by

Ma'rruf Amar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Check Punching Shear of PILE REACTION

Pilecap Specification :
Width

bf := 1500mm

Length

df := 1500mm

Height

hf := 500mm

Vol

Vp := bf df hf
Vp = 1.13 m

Concrete strength

fc := 30MPa

GS of concrete

c := 2400

kgf
m

Yield strength of steel

fy := 400MPa

Thickness of pilecap

hf = 500 mm

Cover concrete

cc := 75mm

Pile cut off (from bottom pilecap)

pco := 75mm

Effective depth

de := hf cc

de = 425 mm
Diameter of pile

dP := 500mm

Perimeter of Shear

bo := dP + de

bo = 2905.97 mm
Maximum Punching Shear Force
Max. Support Reaction

Fymax := 495.55kN = 50.53 tonnef

Selfweight of Pilecap

Wtp := c Vp
Wtp = 2.7 tonnef

Number of Pile in 1 Pilecap

np := 1

Maximum punching shear force

Pumax :=

Ultimate punching shear force

Vn :=

Fymax + Wtp

Pumax
0.75

np

= 53.23 tonnef

= 696.04 kN

Check Nominal Shear Strength


a.

c := 1

Vc1 := 0.17 1 +

b.

s := 20

2
fc 1MPa bo de = 3449.94 kN
c

s de

Vc2 := 0.083

bo

c.

+ 2 fc 1MPa bo de = 2765.2 kN

Vc3 := 0.33 fc 1MPa bo de = 2232.31 kN

Minimum Nominal Shear Strength (provided by concrete), Vc =

Vc := min Vc1 , Vc2 , Vc3

Vc = 2232.31 kN
Status :=

"OKE" if Vc > Vn
"NOT OKE" if Vc Vn

Status = "OKE"

Check Punching Shear of COLUMN REACTION

Column Specification :
Width

bp := 300mm

Length

dp := 300mm

527.3
kN = 703.07 kN
0.75

Punching Shear

Vn 2 :=

Effective depth

de = 425 mm

Perimeter of shear

bo2 := 2 bp + de + dp + de

) (

bo2 = 2900 mm
bp
c 2 :=

=1
dp

c.2 for column

Check Nominal Shear Strength


a.

c 2=1

Vck1 := 0.17 1 +

b.

s = 20

s de

Vck2 := 0.083

c.

2
fc 1MPa bo2 de = 3442.85 kN
c 2

bo2

+ 2 fc 1MPa bo2 de = 2762.89 kN

Vck3 := 0.33 fc 1MPa bo2 de = 2227.72 kN

Vck := min Vck1 , Vck2 , Vck3 = 2227.72 kN

Status2 :=

"OKE" if Vck > Vn 2


"NOT OKE" if Vck Vn 2

Status2 = "OKE"