BOILER PRESSURE PARTS
COMPONENTS OF BOILER THROUGH
WHICH FEED WATER AND STEAM FLOW
AND HEAT IS ADDED
COMPONENT
HEAT ADDITION
ECONOMISER
6%
DRUM
NIL
WATERWALL
50%
SUPER HEATER
30%
RE HEATER
14%
BOILER PRESSURE PARTS LOCATION
ECONOMISER
PRE HEATS THE FEED WATER
ENTERING THE BOILER BY USING
HEAT IN OUT GOING FLUE GASES
IMPROVES BOILER EFFICIENCY
REDUCE BOILER SIZE
ECONOMISER TYPES
ECO N O M ISER
TU BE DESIGN
PLAIN TU BE
HEAT ADDITION
FI N N E D T U B E N O N S T E A M I N G
STEAM IN G
ARRANGEM ENT
IN LIN E
STAGGERED
COMPARISON OF ECONOMISER
TYPES
PLAIN TUBE
EASY ON LOAD
CLEANING
FINNED TUBE
MORE HEAT
TRANSFER AREA
IN GIVEN VOLUME
ON LOAD
CLEANING
DIFFICULT
Direction of Gas Flow
Inline Arrangement
Direction of Gas Flow
Staggered Arrangement
COMPARISON OF ECONOMISER
TYPES
STAGGERED
HIGH HEAT
TRANSFER RATE
DUE TO
INCREASED
TURBULANCE
ON LOAD
CLEANING
DIFFICULT
INLINE
EASY ON LOAD
CLEANING
ECONOMISER DESIGN
CONSIDERATIONS
OVERALL HEAT TRANSFER AREA
OF ECONOMISER DEPENDS ON
FEED WATER INLET TEMPERATURE
SATURATION TEMP. CORRESPONDING
TO OPERATING PRESSURE
FEED WATER FLOW RATE
GAS TEMP. REQUIRED AT THE OUTLET
OF ECONOMISER
ECONOMISER DESIGN
CONSIDERATIONS
TUBE DIAMETER, LENGTH AND
SPACING ARE DECIDED TO ENSURE
UNIFORM WATER FLOW THROUGH
ALL TUBES WITH LOW RESISTANCE
ECONOMISER FITIN WITH THE
DESIGN OF PRCEDING SECTION
DRAUGHT LOSS IS MINIMUM
PROVISON FOR ON LOAD CLEANING
DEVICE
LOCATION OF ECONOMISER IN A TWO
PASS BOILER
ECONOMISER COIL INSIDE BOILER
ECONOMISER TUBE FAILURE
OVER HEATING
STARVATION
SCALING
CORROSION
INTERNAL
EXTERNAL
EROSION
ECONOMISER RE CIRCULATION
DRUM CONSTRUCTION
FUNCTIONS OF BOILER DRUM
TO SEPARATE WATER AND STEAM
FROM WATER STEAM MIXTURE
MIX WATER SEPARATED WITH
WATER FROM ECONOMISER AND
FEED TO DOWNCOMERS
TO FACILITATE CHEMICAL DOZING
TO FACILITATE BLOWDOWN
DRUM CONNECTIONS
STEAM SEPARATION IN DRUM
GRAVITY
SEPARATION
ADOPTED FOR
LOW PRESSURES
USE BAFFLES TO
CHANGE
DIRECTION OF
FLOW TO
SEPARATE WATER
BY GRAVITY
CENTRIFUGAL AND
GRAVITY
SEPARATION
ADOPTED FOR
HIGH PRESSURES
USE TURBO
SEPARATORS OR
CYCLONE
SEPARATORS TO
IMPART
CENTRIFUGAL
FORCES
GRAVITY SEPARATION USING
BAFFLES
STEAM SEPARATION USING
CYCLONE SEPARATORS
AUXILIARY CONNECTIONS TO
THE BOILER DRUM
CHEMICAL DOZING NOZZLE
BLOWDOWN NOZZLE
FOR THE MEASUREMENT OF
PRESSURE AND TEMPERATURE
WATER LEVEL INDICATORS
SAFETY VALVES AND AIR VENTS
TAPPINGS FOR VARIOUS
MEASUREMENTS ON THE DRUM
THREE PAIRS FOR REMOTE LEVEL
INDICATORS
TWO PAIRS FOR LOCAL LEVEL GAUGES
TWO PAIRS FOR CONDUCTIVITY
MEASUREMENT
TWO PAIRS FOR PRESSURE
MEASUREMENT
THREE PAIRS OF THERMAL PADS FOR
MEASURING DRUM METAL
TEMPERATURE
ONE PAIR FOR HIGH LEVEL AND LOW
LEVEL TRIPS
EFFECTS OF DRUM LEVEL
VARIATIONS
LOW LEVEL
STARVAION AND ULTIMATE FAILURE
OF WATERWALL TUBES
EFFECTS OF DRUM LEVEL
VARIATIONS
HIGH LEVEL
AFFECTS STEAM SEPARATION
CARRY OVER OF WATER BY STEAM
SUPER HEATERS THERMALLY STRESSED
SCALING IN SUPER HEATERS
OVER HEATING OF SUPER HEATERS
WATER HAMMERING IN STEAM PIPES
PITTING ON TURBINE BLADES
AIR VENT AND SAFETY VALVES