INSTRUCTIONS
Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain
for future reference.
MOTOMAN INSTRUCTIONS
MOTOMAN- INSTRUCTIONS
DX200 INSTRUCTIONS
DX200 OPERATORS MANUAL (for each purpose)
DX200 MAINTENANCE MANUAL
The DX200 operators manuals above correspond to specific usage. Be sure to use the appropriate manual.
Part Number:
Revision:
165292-1CD
6
MANUAL NO.
RE-CTO-A220
165292-1CD
DX200 Controller
ii
RE-CTO-A220
165292-1CD
DX200 Controller
MANDATORY
CAUTION
Some drawings in this manual are shown with the protective covers
or shields removed for clarity. Be sure all covers and shields are
replaced before operating this product.
iii
RE-CTO-A220
165292-1CD
DX200 Controller
We suggest that you obtain and review a copy of the ANSI/RIA National
Safety Standard for Industrial Robots and Robot Systems (ANSI/RIA
R15.06-2012). You can obtain this document from the Robotic Industries
Association (RIA) at the following address:
Robotic Industries Association
900 Victors Way
P.O. Box 3724
Ann Arbor, Michigan 48106
TEL: (734) 994-6088
FAX: (734) 994-3338
www.roboticsonline.com
Ultimately, well-trained personnel are the best safeguard against
accidents and damage that can result from improper operation of the
equipment. The customer is responsible for providing adequately trained
personnel to operate, program, and maintain the equipment. NEVER
ALLOW UNTRAINED PERSONNEL TO OPERATE, PROGRAM, OR
REPAIR THE EQUIPMENT!
We recommend approved Yaskawa training courses for all personnel
involved with the operation, programming, or repair of the equipment.
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications.
iv
RE-CTO-A220
165292-1CD
DX200 Controller
DANGER
WARNING
CAUTION
MANDATORY
PROHIBITED
NOTE
RE-CTO-A220
165292-1CD
DX200 Controller
WARNING
Injury may result if anyone enters the P-point maximum envelope of the
manipulator during operation. Always press an emergency stop button
immediately if there are problems.The emergency stop buttons are
located on the right of the front door of the DX200 and the programming
pendant.
vi
RE-CTO-A220
165292-1CD
DX200 Controller
CAUTION
Manual Designation
DX200 Controller
DX200
Programming Pendant
Manipulator Cable
vii
RE-CTO-A220
165292-1CD
DX200 Controller
Manual Designation
Programming Character
Pendant
Keys
Symbol
Keys
Axis Keys
Number Keys
Registered Trademark
In this manual, names of companies, corporations, or products are
trademarks, registered trademarks, or brand names for each company or
corporation. The indications of (R) and TM are omitted.
viii
RE-CTO-A220
165292-1CD
DX200 Controller
DANGER
WARNING
WARNING
Do not enter
robot
work area.
Moving parts
may cause
injury
WARNING
WARNING
High Voltage
Do not open the door
with power ON.
High Voltage
Do not open the cover.
WARNING
May cause
electric shock.
Ground the earth
terminal based on
local and national
electric code.
WARNING
High Voltage
Do not ope the cover.
WARNING
High Voltage
Do not open the door
with power ON.
WARNING
May cause
electric shock.
Ground the earth
terminal based on
local and national
electric code.
Internal Breaker
ix
RE-CTO-A220
165292-1CD
DX200 Controller
For routine technical inquiries, you can also contact Motoman Customer
Support at the following e-mail address:
[email protected]
NOTE
DX200 Controller
Robots
Primary Application
Controller
DX200
Software Version
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
Table of Contents
1 Safety.............................................................................................................................................. 1-1
1.1 For Your Safety.................................................................................................................. 1-1
1.2 Special Training ................................................................................................................. 1-2
1.3 Motoman Manual List ........................................................................................................ 1-2
1.4 Personnel Safety ............................................................................................................... 1-3
1.5 Motoman Safety................................................................................................................. 1-5
1.5.1 Installation and Wiring Safety ............................................................................... 1-5
1.5.2 Work Area Safety ................................................................................................. 1-9
1.5.3 Operation Safety ................................................................................................ 1-10
1.6 Notes for Moving and Transferring the MOTOMAN ........................................................ 1-13
1.7 Notes on MOTOMAN Disposal........................................................................................ 1-14
2 Product Confirmation ...................................................................................................................... 2-1
2.1 Contents Confirmation ....................................................................................................... 2-1
2.2 Order Number Confirmation .............................................................................................. 2-2
3 Installation....................................................................................................................................... 3-1
3.1 Handling Procedure ........................................................................................................... 3-1
3.1.1 Using a Crane to Move the Controller .................................................................. 3-1
3.1.2 Using a Forklift to Move the Controller ................................................................. 3-2
3.2 Place of Installation............................................................................................................ 3-3
3.3 Location ............................................................................................................................. 3-4
3.4 Mounting the Controller ..................................................................................................... 3-5
3.5 Procedure of Stacking the Controllers ............................................................................... 3-6
4 Connection...................................................................................................................................... 4-1
4.1 Notes on Cable Junctions.................................................................................................. 4-2
4.2 Power Supply..................................................................................................................... 4-3
4.2.1 Three-Phase Power Supply.................................................................................. 4-3
4.2.2 Noise Filter Installation ......................................................................................... 4-3
4.2.3 Leakage Breaker Installation ................................................................................ 4-4
4.2.4 Primary Power Supply Breaker Installation .......................................................... 4-5
xi
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
xii
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
8.2 Setting the Second Home Position (Check Point) ........................................................... 8-12
8.2.1 Purpose of Position Check Operation ................................................................ 8-14
8.2.2 Procedure for the Second Home Position Setting (Check Point) ....................... 8-16
8.2.3 Procedure after the Alarm .................................................................................. 8-18
8.3 Tool Data Setting ............................................................................................................. 8-20
8.3.1 Registering Tool Files......................................................................................... 8-20
8.3.1.1 Number of Tool Files ............................................................................. 8-20
8.3.1.2 Registering Coordinate Data ................................................................. 8-20
8.3.1.3 Registering Tool Angle .......................................................................... 8-23
8.3.1.4 Setting the Tool Load Information ......................................................... 8-24
8.3.2 Tool Calibration .................................................................................................. 8-25
8.3.2.1 Tool Calibration ..................................................................................... 8-25
8.3.2.2 Setting of Tool Calibration Method ........................................................ 8-25
8.3.2.3 Teaching of Calibration Point ................................................................ 8-26
8.3.2.4 Clearing Calibration Data ...................................................................... 8-32
8.3.2.5 Checking the TCP ................................................................................. 8-34
8.3.3 Automatic Measurement of the Tool Load and the Center of Gravity ................ 8-36
8.3.3.1 What is the Automatic Measurement of the Tool Load and
the Center of Gravity? ........................................................................... 8-36
8.3.3.2 Measurement of the Tool Load and the Center of Gravity .................... 8-36
8.4 ARM Control .................................................................................................................... 8-41
8.4.1 ARM Control ....................................................................................................... 8-41
8.4.2 ARM CONTROL Window ................................................................................... 8-41
8.4.2.1 Robot Setup Condition .......................................................................... 8-42
8.4.3 Tool Load Information Setting ............................................................................ 8-46
8.4.3.1 Tool Load Information ........................................................................... 8-46
8.4.3.2 How to Calculate Tool Load Information ............................................... 8-47
8.4.3.3 Tool Load Information Registering ........................................................ 8-52
8.5 Work Home Position ........................................................................................................ 8-55
8.5.1 What is the Work Home Position?...................................................................... 8-55
8.5.2 Setting Work Home Position............................................................................... 8-55
8.5.2.1 Work Home Position Window................................................................ 8-55
8.5.2.2 Registering/Changing the Work Home Position .................................... 8-57
8.5.2.3 Returning to the Work Home Position ................................................... 8-58
8.5.2.4 Output of the Work Home Position Signal............................................. 8-58
8.6 Interference Area ............................................................................................................. 8-59
8.6.1 Interference Area................................................................................................ 8-59
8.6.2 Cubic Interference Area...................................................................................... 8-59
8.6.2.1 Cubic Interference Area ........................................................................ 8-59
8.6.2.2 Cube Setting Method ............................................................................ 8-60
8.6.2.3 Setting Operation .................................................................................. 8-61
xiii
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
xiv
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
xv
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
xvi
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
xvii
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
xviii
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
xix
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
xx
RE-CTO-A220
165292-1CD
DX200 Controller
Table of Contents
xxi
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.1 For Your Safety
Safety
1.1
MANDATORY
Prepare
SAFETY WORK REGULATIONS
Observe
JIS B 8433-1:2007
(ISO 10218-1:2006)
INDUSTRIAL ROBOT- SAFETY REQUIREMENTS
Reinforce the
SAFETY MANAGEMENT SYSTEM
1-1
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.2 Special Training
1.2
Special Training
MANDATORY
The telephone numbers are listed on the back cover of this manual.
1.3
MANDATORY
1-2
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.4 Personnel Safety
1.4
Personnel Safety
The entire manipulator P-point maximum envelope is potentially
dangerous.
All personnel working with the MOTOMAN (safety administration,
installation, operation, and maintenance personnel) must always be
prepared and "Safety First" minded, to ensure the safety of all personnel.
WARNING
Failure to observe this caution may result in injury due to contact with
DX200, controller, the workpiece, the positioner, etc.
1-3
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.4 Personnel Safety
CAUTION
1-4
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.5 Motoman Safety
1.5
Motoman Safety
The followings are safty functions of MOTOMAN / DX200.
Emergency stop SW input (controller/programming pendant)
Enable SW input (programming pendant)
Safeguarding interlock signal input (safety plug)
External emergency stop SW input
External enable SW input
Servo power enable input
Overrun input (manipulator/external axis)
Universal safety input
These safety functions conform to the following safety standards.
EN ISO 13849-1:2008 + AC:2009 Cat.4 / PL e
EN 62061:2005 + AC:2010 + A1:2013 / IEC 61508 Part 1-7:2010 SIL3
The use frequency of each switch for safety functions is assumed as
below.
Emergency stop SW
500 times/ year
External emergency stop SW
500 times/ year
Enable SW (programming pendant) 2000 times/ year
External enable SW
2000 times/ year
1.5.1
WARNING
DX200
Door
1000 mm or more
1000 mm or more
1000 mm or more
1-5
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.5 Motoman Safety
CAUTION
Wire Rope
DX200
Weight (Kg)
100
Medium /Large
capacity model
100
DX200
1-6
RE-CTO-A220
165292-1CD
1 Safety
1.5 Motoman Safety
CAUTION
520
500
520
DX200
DX200
500
730
600
DX200
586
690
DX200 Controller
Install the manipulator using bolts of the size and type specified for
each MOTOMAN in the MOTOMAN INSTRUCTION MANUAL.
1-7
RE-CTO-A220
165292-1CD
1 Safety
1.5 Motoman Safety
CAUTION
Attach the DX200 to the floor or rack, etc., using the screw holes on the
bottom of the DX200.
Failure to observe this caution could lead to injury or equipment
damage if the DX200 should shift or fall.
DX200
40
14 dia.
(2 holes)
60
40
DX200 Controller
30
50
(Unit: mm)
Recomended plate thickness : 6mm
SAFETY
FIRST
Piping
Lead
Cable Channnel
1-8
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.5 Motoman Safety
1.5.2
WARNING
CAUTION
Tools and loose equipment should not be left on the floor around the
manipulator, DX200, or welding fixture, etc., as injury or damage to
equipment can occur if the manipulator comes in contact with objects or
equipment left in the work area.
1-9
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.5 Motoman Safety
1.5.3
Operation Safety
WARNING
DX200
ENERGING
PROHIBITED
PADLOCK
Turning the power ON during tool installation may case electric shock
or injury due to unexpected movement of the manipulator.
1-10
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.5 Motoman Safety
WARNING
Injury may result from contact with the manipulator if persons enter the
P-point maximum envelope of the manipulator.
Press the emergency stop button immediately if there are problems.
The emergency stop buttons are located on the right of the front door of
the DX200 and the programming pendant.
Programming Pendant
DX200
1-11
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.5 Motoman Safety
CAUTION
MANDATORY
1-12
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.6 Notes for Moving and Transferring the MOTOMAN
1.6
CAUTION
1-13
RE-CTO-A220
165292-1CD
DX200 Controller
1 Safety
1.7 Notes on MOTOMAN Disposal
1.7
PROHIBITED
CAUTION
1-14
RE-CTO-A220
165292-1CD
DX200 Controller
2 Product Confirmation
2.1 Contents Confirmation
Product Confirmation
2.1
Contents Confirmation
Confirm the contents of the delivery when the product arrives.
Standard delivery includes the following five items (Information for the
content of optional goods is given separately):
Manipulator
DX200
Programming Pendant
Manipulator Cable (Between Manipulator and DX200)
Complete Set of Manuals
Fig. 2-1: Standard Five Items
Programming
Pendant
DX200
Manipulator
Manipulator Cable
2-1
RE-CTO-A220
165292-1CD
DX200 Controller
2 Product Confirmation
2.2 Order Number Confirmation
2.2
<Example>
ORDER NO.
S78796-1
2-2
RE-CTO-A220
165292-1CD
DX200 Controller
3 Installation
3.1 Handling Procedure
Installation
3.1
Handling Procedure
CAUTION
3.1.1
Wire Rope
Weight (Kg)
100
Medium /Large
capacity model
100
DX200
3-1
RE-CTO-A220
165292-1CD
DX200 Controller
3 Installation
3.1 Handling Procedure
3.1.2
Protective padding
Tiedown straps
Palette
Forklift
3-2
RE-CTO-A220
165292-1CD
DX200 Controller
3 Installation
3.2 Place of Installation
3.2
Place of Installation
The conditions listed below must be met before installing the DX200:
Ambient temperature must be 0 to 45C (32 to 113F) during
operation and -10 to 60C (14 to 140F) during transportation and
maintenance.
Humidity must be low with no condensation (10~90%RH).
It must be a place with little dirt, dust, or water.
No flammable or corrosive liquids or gases, etc. in the area.
Little jarring or potential for striking of the DX200
(under 0.5 oscillation).
No large electric noise source (such as a TIG welding device, etc.)
nearby.
No potential for collision with moving equipment such as forklifts.
NOTE
3-3
RE-CTO-A220
165292-1CD
DX200 Controller
3 Installation
3.3 Location
Location
1. Install the DX200 outside of the P-point maximum envelope of the
manipulator (outside of the safeguarding.)
Fig. 3-1: Location of DX200
Safeguarding
DX200
Door
1000 mm or more
1000 mm or more
1000 mm or more
520
500
3. Install the controller in a location from which you can easily inspect it
when the door is open.
DX200
586
690
3.3
DOOR
3-4
RE-CTO-A220
165292-1CD
DX200 Controller
3 Installation
3.4 Mounting the Controller
4. Install the controller at least 500 mm from the nearest wall to allow
maintenance access.
520
DX200
DX200
500
730
600
CAUTION
DX200
40
60
14 dia.
(2 holes)
40
3.4
30
50
(Unit: mm)
Recomended plate thickness : 6mm
NOTE
3-5
RE-CTO-A220
165292-1CD
DX200 Controller
3 Installation
3.5 Procedure of Stacking the Controllers
3.5
Note
There are restrictions to stack the DX200 controllers. Please read through
the following restrictions before installing the DX200.
* The following restrictions apply to both upper and lower controllers.
Restrictions: as for medium and large capacity controllers, the controllers
only for the spot welding are able to be stacked. Other controllers, such as
for handling, cannot be stacked. The controllers for the small capacity can
be stacked regardless of the uses.
Follow the procedures below when stacking the DX200 controllers.
1. Remove the four eyebolts (4 places) on the top of the DX200 to be
stacked lower level.
M12 eyebolts (4 places)
Top View
2. Lift the controller by using the crane, and stack the controllers. Refer
to section 3.1.1 Using a Crane to Move the Controller on page 3-1,
when use the crane.
Controller (upper)
Stacking
Controller (lower)
3-6
RE-CTO-A220
165292-1CD
DX200 Controller
3 Installation
3.5 Procedure of Stacking the Controllers
CAUTION
Failure to observe this caution may cause the personal injury or the
equipment damage.
3. After stacking the controllers, remove the grommets inside (A-A
section a part) of the upper controller. Install the M12 bolts
(length:35 mm), spring washers and washers for temporally.
M12 (length:35mm)
Grommet (2 places)
Upper
Spring washer
Washer
a enlarged view
Lower
Back board
Connector plate
Back View
3-7
RE-CTO-A220
165292-1CD
DX200 Controller
3 Installation
3.5 Procedure of Stacking the Controllers
CAUTION
When remove the connector plate from the controller, perform with
the great caution to avoid damaging the internal cables.
Grommet (2 places)
Upper
Spring washer
Washer
b enlarged view
Lower
3-8
RE-CTO-A220
165292-1CD
DX200 Controller
3 Installation
3.5 Procedure of Stacking the Controllers
8. Remove the wire lifting the controller by the crane, and stacking is
completed.
3-9
RE-CTO-A220
165292-1CD
DX200 Controller
Connection
Connection
WARNING
Before wiring, make sure to turn OFF the primary power supply, and
put up a warning sign. (ex. DO NOT TURN THE POWER ON)
Failure to observe this caution may result in injury and electric shock.
Do not touch any board inside the controller for five minutes after
turning OFF the power supply.
Failure to observe this caution may result in fire and electric shock.
Loose power circuit wires can cause fire and electric shock.
4-1
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.1 Notes on Cable Junctions
4.1
SAFETY
FIRST
PIPING
LEAD
cable channel
4-2
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.2 Power Supply
4.2
4.2.1
Power Supply
Three-Phase Power Supply
NOTE
Breaker
3-phase
200/220V AC at 60Hz
or
200V AC 50Hz
To the converter
Fuse
Noise Filter
To control
power supply
unit
4.2.2
3-phase
200/220V AC at 60Hz
or
200V AC 50Hz
DX200
Contactor
-/
Breaker
To converter
Fuse
Noise Filter
To control
power supply
unit
4-3
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.2 Power Supply
4.2.3
Model
3-phase
200/220V AC at 60Hz
or
200V AC 50Hz
Leakage
Breaker
DX200
Contactor
(1KM)
Breaker
To converter
Fuse
Noise Filter
To control
power supply
unit
4-4
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.2 Power Supply
4.2.4
Breaker
Breaker
Breaker
Controller
for Positioner
DX200
Power
Source
Table 4-2: DX200 Power Capacity, Cable Sizes, and Breaker Capacities
Manipulator
Power
capacity
(kVA)
Capacity of
breaker in
DX200 (A)
(mm2)
MA1440
1.5
3.5 (M5)
15
MH12
1.5
3.5 (M5)
15
MS210
5.0
5.5 (M5)
30
The maximum load value (payload, operation speed, and frequency, etc.)
is displayed.
However, the power capacity is different depending on work conditions.
Inquire at the nearest branch office listed on the back cover for information
when selecting the transformer.
SUPPLEMENT
NOTE
For the models which are not in Table 4-2, refer to DX200
INSTRUCTIONS SUPPLEMENT FOR Controller
Specification List: ANSI Specification (171270-1CD).
4-5
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.3 Connection Methods
4.3
Connection Methods
A connection diagram for the manipulator, manipulator cable, primary
power cable and programming pendant is shown below.
Fig. 4-6: Cable Connection
Manipulator
DX200
Primary Power
Supply Cable
Manipulator
Cable
Programming
Pendant Cable
4.3.1
door lock
clockwise
90
flathead screw d
4-6
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.3 Connection Methods
(2) Rotate the main power supply switch to the "OFF" position and
open the door gently.
Fig. 4-8: Rotating the Main Power Supply Switch to the OFF Position
DX200
DX200
Primary Power
Supply Cable
WARNING
Cable clamp must be used when connecting primary power supply.
Make sure that the cable clamp is fastened tightly to prevent dust or
water from entering.
Failure to observe this caution may result in electric shock or
breakdown of DX200.
4-7
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.3 Connection Methods
(1) Pull off the primary cover of the switch which is on the upper right
side of the DX200.
Fig. 4-10: Pulling Off the Cover
(2) Connect a ground wire to reduce noise and prevent electric shock.
I)
4-8
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.3 Connection Methods
II)
NOTE
DX200
Exclusive Grounding
100 ohm maximum
ground resistance
NOTE
Dont connect the grounding wire with the wires for the
electric power source, the welder, etc.
Ground in accordance with all relevant governmental
regulations when using metallic ducts, metallic conduits,
and cable tray to construct the cable.
4-9
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.3 Connection Methods
(4) Install the cover.
Fig. 4-14: Install the Cover
4-10
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.3 Connection Methods
4.3.2
NOTE
counterclockwise 90
door lock
4-11
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.3 Connection Methods
WARNING
Always close the door of the controller (DX200) except for
maintenance.
Make sure to rotate all the door locks counterclockwise.
If dust or water enter inside the controller, electric shock or breakdown
of DX200 may result.
4.3.3
Alignment mark
4-12
RE-CTO-A220
165292-1CD
DX200 Controller
4 Connection
4.3 Connection Methods
4.3.4
Cable support
Back View
4-13
RE-CTO-A220
165292-1CD
DX200 Controller
WARNING
The main power supply is turned ON when the main power supply switch
on the front of the DX200 is turned to the "ON" position, and the initial
diagnosis and the current position setting begin.
Fig. 5-1: Turning ON the Main Power Supply
DX200
5-1
RE-CTO-A220
165292-1CD
DX200 Controller
Initial Diagnosis
The initial diagnosis are performed in the DX200 when main power is
turned ON, and the startup window is shown on the programming pendant
screen.
Fig. 5-2: Startup Window
5.1.2
CAUTION
Make sure that a system manager stores the key of the mode select
switch on the programming pendant.
After operation, the key should be removed and stored by the
system manager.
5-2
RE-CTO-A220
165292-1CD
DX200 Controller
5.2
5.2.1
Light
SERVO ON
NOTE
5.2.2
Flicker
SERVO ON
5-3
RE-CTO-A220
165292-1CD
DX200 Controller
SUPPLEMENT
Servo On
NOTE
Squeeze -> ON
Play Mode
Teach Mode
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Invalid
Invalid
Valid
Invalid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Speed Limit
Invalid
Valid
Safety Signal
5-4
RE-CTO-A220
165292-1CD
DX200 Controller
5.3
5.3.1
Programming Pendant
EMERGENCY STOP
5.3.2
DX200
NOTE
If turn the DX200 power supply OFF during the data writing,
the data may be broken. Do not turn the power supply OFF
when the hour glass pointer is seen on the programming
pendant.
5-5
RE-CTO-A220
165292-1CD
DX200 Controller
Operation Mode
Safety Signal
Stop
Category 0
Stop
Category 1
Stop
Category 2
5-6
RE-CTO-A220
165292-1CD
DX200 Controller
WARNING
Press the emergency stop button on the right of the front door of the
DX200 and the programming pendant before operating the
manipulator. Confirm that the SERVO ON lamp is turned OFF.
Injury may result from collision with the manipulator to anyone entering
the P-point maximum envelope of the manipulator.
6-1
RE-CTO-A220
165292-1CD
DX200 Controller
CAUTION
Make sure that a system manager stores the key of the mode select
switch on the programming pendant.
After operation, the key should be removed and stored by the
system manager.
6-2
RE-CTO-A220
165292-1CD
DX200 Controller
6.1
NOTE
Be sure to remove all items from the area before moving the
manipulator.
Refer to the INSTRUCTION MANUAL for the appropriate
position of the fixture.
U-Axis
R-Axis
B-Axis
X-
X+
S-
X-
S+
Y-
Y+
L-
L+
Z-
U+
E-
R+
Y-
Y+
Z-
Z+
T-
T+
B-
Z+
U-
X+
R-
E+
T-Axis
E-Axis
B+
8-
L-Axis
8+
Axis Keys
S-Axis
X-
X+
S-
X+
S+
R+
XR-
Y-
B-
Y+
Y-
L+
L-
Y+
B+
Rotates wrist
Z+
U+
Z+
T+
ZT-
Z-
U-
E+
6-3
RE-CTO-A220
165292-1CD
DX200 Controller
6.2
POWER
BRAKE RELEASE
4000
ON
(1CN)
(2CN)
2CN
OFF
2BC
Manipularor type
Unitmm
This brake release unit can be used in a state that the motor servo ON can
not be executed from the DX200 controller.
Be very careful about the followings when using.
CAUTION
6-4
RE-CTO-A220
165292-1CD
DX200 Controller
7 Security System
7.1 Protection Through Security Mode Settings
Security System
7.1
7.1.1
Security Mode
There are five security modes operation mode, editing mode,
management mode, safety mode and one time manage mode. Editing
mode, management mode and safety mode require a user ID.
For the editing mode and the management mode, the user ID should be 4
or more and 16 or less characters with number(s) and symbol(s). As for
the safety mode, it should be 9 or more and 16 or less characters with
number(s) and symbol(s).
(Significant numbers and symbols: 0 to 9, -, .. )
Operating the one time manage mode requires to enter the security code,
which is issued by YASKAWA sales representative.
Table 7-1: Security Mode Descriptions
Security Mode
Explanation
Operation Mode
Editing Mode
This mode allows the operator to teach and edit jobs and
robot settings.
Management
Mode
Safety Mode
One Time
Manage Mode
7-1
RE-CTO-A220
165292-1CD
DX200 Controller
7 Security System
7.1 Protection Through Security Mode Settings
Sub Menu
JOB
JOB
Operation
Operation
Edit
Edit
MASTER JOB
Operation
Edit
JOB CAPACITY
Operation
Edit
Edit
Operation
(JOB)1)
RES. STATUS2)
IN/OUT
EDIT
Operation
SELECT JOB
RES. START
VARIABLE
DISPLAY
CYCLE
Operation
Operation
Edit
Edit
Edit
Edit
Edit
Edit
BYTE
Operation
Edit
INTEGER
Operation
Edit
DOUBLE
Operation
Edit
REAL
Operation
Edit
STRING
Operation
Edit
POSITION (ROBOT)
Operation
Edit
POSITION (BASE)
Operation
Edit
POSITION (ST)
Operation
Edit
LOCAL VARIABLE
Operation
TIMER
Operation
Edit
EXTERNAL INPUT
Operation
Edit
EXTERNAL OUTPUT
Operation
Edit
UNIVERSAL INPUT
Operation
Operation
UNIVERSAL OUTPUT
Operation
Operation
SPECIFIC INPUT
Operation
SPECIFIC OUTPUT
Operation
RIN
Operation
REGISTER
Operation
Management
AUXILIARY RELAY
Operation
CONTROL INPUT
Operation
Operation
Management
NETWORK INPUT
Operation
NETWORK OUTPUT
Operation
ANALOG OUTPUT
Operation
SV POWER STATUS
Operation
LADDER PROGRAM
Management Management
I/O ALARM
Management Management
I/O MESSAGE
Management Management
TERMINAL
Operation
Edit
Operation
Operation
SERVO ON FACTOR
Management -
Operation
7-2
RE-CTO-A220
165292-1CD
DX200 Controller
7 Security System
7.1 Protection Through Security Mode Settings
Table 7-2: Menu & Security Mode (Sheet 2 of 4)
Main Menu
Sub Menu
ROBOT
CURRENT POSITION
DISPLAY
EDIT
Operation
COMMAND POSITION
Operation
SERVO MONITOR
Management -
Operation
Edit
Operation
Edit
DROP AMOUNT
Management Management
Operation
TOOL
Edit
Edit
INTERFERENCE
Management Management
Operation
Edit
USER COORDINATE
Edit
Edit
HOME POSITION
Management Management
MANIPULATOR TYPE
Management -
ANALOG MONITOR
Management Management
OVERRUN&S-SENSOR1)
Operation
Operation
Edit
Edit
LIMIT
RELEASE1)
ARM CONTROL1)
SYSTEM INFO
EX. MEMORY
PARAMETER
Management Management
SHIFT VALUE
Operation
SOFTLIMIT SETTING
Management Management
Operation
VERSION
Operation
MONITORING TIME
Operation
Management
ALARM HISTORY
Operation
Management
Operation
Management
LOGDATA
Operation
Management
Operation
Edit
QR CODE
Operation
Operation
SECURITY
Operation
Operation
LOAD
Edit
SAVE
Operation
VERIFY
Operation
DELETE
Operation
DEVICE
Operation
Operation
FOLDER
Operation
Management
INITIALIZE1)
Operation
S1CxG
Management Management
S2C
Management Management
S3C
Management Management
S4C
Management Management
A1P
Management Management
A2P
Management Management
A3P
Management Management
A4P
Management Management
A5P
Management Management
A6P
Management Management
A7P
Management Management
7-3
RE-CTO-A220
165292-1CD
DX200 Controller
7 Security System
7.1 Protection Through Security Mode Settings
Table 7-2: Menu & Security Mode (Sheet 3 of 4)
Main Menu
Sub Menu
PARAMETER
A8P
Management Management
RS
Management Management
S1E
Management Management
S2E
Management Management
S3E
Management Management
S4E
Management Management
S5E
Management Management
S6E
Management Management
S7E
Management Management
DISPLAY
SETUP
S8E
Management Management
TEACHING COND.
Edit
Management Management
OPERATE ENABLE
Management Management
FUNCTION ENABLE
Management Management
JOG COND.
Management Management
PLAYBACK COND.
Management Management
FUNCTION COND.
Management Management
Edit
LOGDATA COND.
Management Management
Edit
DATE/TIME
Management Management
GRP COMBINATION
Management Management
SET WORD
Edit
Edit
Edit
Edit
USER ID
Edit
Edit
SET SPEED
Management Management
KEY ALLOCATION
Management Management
Edit
Management Management
Management Management
Management
Edit
Management
Edit
Management
ENCODER MAINTENANCE
Edit
Management
SETTM SETUP
Edit
Management
DISPLAY
SETUP
Edit
OPERATE COND.
PM
EDIT
Operation
Safety
Operation
Safety
Operation
Safety
PM (REDUCER)
Operation
Management
PM (HARDWARE)
Management Management
INSPECTION NOTICE
Operation
Edit
INSPECTION RECORD
Operation
Management
CHANGE FONT
Operation
Operation
CHANGE BUTTON
Operation
Operation
INITIALIZE LAYOUT
Operation
Operation
Operation
Operation
7-4
RE-CTO-A220
165292-1CD
DX200 Controller
7 Security System
7.1 Protection Through Security Mode Settings
Table 7-2: Menu & Security Mode (Sheet 4 of 4)
Main Menu
Sub Menu
EDIT
Operation
Edit
Operation
Edit
Operation
Edit
Operation
Edit
Operation
Edit
WEAVING
Operation
Edit
ARC MONITOR
Operation
Edit
Operation
APPLI COND.
Management Management
HANDLING
HANDLING DIAGNOSIS
Operation
Edit
SPOT
WELDING
WELD DIAGNOSIS
Operation
Edit
I/O ALLOCATION
Management Management
GUN CONDITION
Management Management
Management Management
APPLICATION CONDITION
SETTING
Management Management
WELD DIAGNOSIS
Operation
Edit
GUN PRESSURE
Edit
Edit
PRESSURE
Edit
Edit
I/O ALLOCATION
Management Management
GUN CONDITION
Management Management
CLEARANCE SETTING
Operation
Management Management
TIP INSTALLATION
Operation
APPLICATION CONDITION
SETTING
Management Management
WEAVING
Operation
Edit
GENERAL DIAG.
Operation
Edit
Management Management
PAINT SPECIAL
Management Management
PAINT CONDITION
Operation
Edit
CALIBRATION CONFIG.
Operation
Edit
Management Management
TIME CHART
Operation
Edit
Operation
Edit
SPOT
WELDING
(MOTOR GUN)
GENERAL
PAINT
COMMON TO
ALL
APPLICATIONS
Edit
Management
Management Management
Operation
Operation
7-5
RE-CTO-A220
165292-1CD
DX200 Controller
7.1.1.1
7 Security System
7.1 Protection Through Security Mode Settings
Note: Icons for the main menu, such as arc welding system, differ
depending on the system being used.
2. Select {SECURITY}.
The selection window of security mode appears.
7-6
RE-CTO-A220
165292-1CD
DX200 Controller
7 Security System
7.1 Protection Through Security Mode Settings
Security mode can be selected from OPERATION MODE,
EDITING MODE, MANAGEMENT MODE or SAFETY MODE.
7-7
RE-CTO-A220
165292-1CD
DX200 Controller
7 Security System
7.1 Protection Through Security Mode Settings
7-8
RE-CTO-A220
165292-1CD
DX200 Controller
7 Security System
7.1 Protection Through Security Mode Settings
7.1.2
User ID
User ID is requested when the editing mode, management mode or safety
mode is operated.
The user ID should be 4 or more and 16 or less characters with number(s)
and symbol(s) for the editing mode and the management mode. As for
the safety mode, it should be 9 or more and 16 or less characters with
number(s) and symbol(s).
(Significant numbers and symbols: 0 to 9, -, ..)
7.1.2.1
Changing User ID
In order to change the user ID, the DX200 must be in the editing mode,
the management mode or the safety mode. Higher security modes can
make changes the user ID of to lower security modes.
1. Select {SETUP} under the main menu.
The sub menu appears.
7-9
RE-CTO-A220
165292-1CD
DX200 Controller
7 Security System
7.1 Protection Through Security Mode Settings
3. Select the desired ID.
The character input line appears, and a message "Input current ID
no. (4 or more digits)" appears.
(As for the safety mode, 9 or more digits)
7-10
RE-CTO-A220
165292-1CD
DX200 Controller
System Setup
System Setup
WARNING
8-1
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.1 Home Position Calibration
8.1
WARNING
Injury may result from contact with the manipulator if persons enter the
P-point maximum envelope of the manipulator.
Always press the emergency stop button immediately if there are
problems.
Emergency stop buttons are located on the right of the front door of the
DX200 and the programming pendant.
8-2
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.1 Home Position Calibration
CAUTION
Make sure that a system manager stores the key of the mode select
switch on the programming pendant.
After operation, the key should be removed and stored by the
system manager.
8-3
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.1 Home Position Calibration
8.1.1
NOTE
Teaching and playback are not possible before the completion of the home position calibration.
In a system with two or more manipulators, the home
position of all the manipulators must be calibrated before
starting teaching or playback.
Home Position
SUPPLEMENT
The home position is the pulse value "0" for each axis and its
posture. See section 8.1.3 Home Position of the Robot on
page 8-11.
8-4
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.1 Home Position Calibration
8.1.2
Calibrating Operation
NOTE
8.1.2.1
8-5
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.1 Home Position Calibration
3. Select {DISPLAY} under the menu.
The pull-down menu appears.
8-6
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.1 Home Position Calibration
5. Select {EDIT} under the menu.
The pull-down menu appears.
7. Select {YES}.
Displayed position data of all axes are registered as home position.
When {NO} is selected, the registration will be canceled.
8-7
RE-CTO-A220
165292-1CD
DX200 Controller
8.1.2.2
8 System Setup
8.1 Home Position Calibration
5. Select {YES}.
Displayed position data of the axis is registered as home position.
When {NO} is selected, the registration will be canceled.
8-8
RE-CTO-A220
165292-1CD
DX200 Controller
8.1.2.3
8 System Setup
8.1 Home Position Calibration
8.1.2.4
8-9
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.1 Home Position Calibration
3. Select {DATA} under the main menu.
The pull-down menu appears
5. Select {YES}.
All absolute data are cleared.
8-10
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.1 Home Position Calibration
8.1.3
NOTE
8-11
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.2 Setting the Second Home Position (Check Point)
8.2
WARNING
Injury may result from contact with the manipulator if persons enter the
P-point maximum envelope of the manipulator.
Press the emergency stop button immediately whenever there are
problems.
8-12
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.2 Setting the Second Home Position (Check Point)
CAUTION
Make sure that a system manager stores the key of the mode select
switch on the programming pendant.
After operation, the key should be removed and stored by the
system manager.
8-13
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.2 Setting the Second Home Position (Check Point)
8.2.1
Reset alarm
Position confirmation
operation
2
Compare second home
position (check point)*
pulses with current
position pulses
NG
OK
3
Playback possible
Position Check
After the "OUT OF RANGE (ABSO DATA)" alarm occurs, move to the
second home position using the axis keys and perform the position
confirmation. Playback and test runs will not function unless "CONFIRM
POSITION" is performed.
8-14
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.2 Setting the Second Home Position (Check Point)
2
The pulse number at the second home position is compared with that at
the current position. If the difference is within the allowable range,
playback is enabled. If not, the alarm occurs again.
The allowable range pulse is the number of pulses per rotation of the
motor (PPR data).
The initial value of the second home position is the home position
(where all axes are at pulse 0). The second home position can be
changed. For details, refer to section 8.2.2 Procedure for the
Second Home Position Setting (Check Point) on page 8-16.
3
Alarm Occurrence
If the alarm occurs again, there may be an error in the PG system. Check
the system. After adjusting the erroneous axis, calibrate the home
position of the axis, then check the position again.
NOTE
8-15
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.2 Setting the Second Home Position (Check Point)
8.2.2
8-16
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.2 Setting the Second Home Position (Check Point)
3. Press the [PAGE], or select [PAGE] to display the selection window for
the control group.
When there are two or more group axes, select the group axes to
which the second home position is to be specified.
8-17
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.2 Setting the Second Home Position (Check Point)
8.2.3
WARNING
8-18
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.2 Setting the Second Home Position (Check Point)
3. Press the [PAGE], or select [PAGE] to display the selection window for
the control group.
When there are two or more group axes, select the group axes to
which the second home position is to be specified.
4. Press [FWD].
TCP moves to the second home position. The robot moving speed is
set as selected manual speed.
5. Select {DATA} under the menu.
6. Select {CONFIRM POSITION}.
A message Home position checked appears.
Pulse data of the second home position and current pulse data are
compared. If the compared error is in allowed range, playback
operation can be done.
If the error is beyond the allowed range, the alarm occurs again.
8-19
RE-CTO-A220
165292-1CD
DX200 Controller
8.3.1.1
8 System Setup
8.3 Tool Data Setting
8.3
8.3.1
TOOL FILE 0
TOOL FILE 63
SUPPLEMENT
8.3.1.2
XF
YF
Tool
TCP
ZF
8-20
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
1. Select {ROBOT} under the main menu.
The sub menu appears.
2. Select {TOOL}.
(1) Move the cursor to the number of the desired tool, and press
{SELECT} in the tool list window.
(2)
To switch the tool list window and the tool coordinate window, press
{DISPLAY} {LIST} or {DISPLAY} {COORDINATE DATA}.
8-21
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
6. Press [ENTER].
The coordinate data is registered.
<Setting Example>
260 mm
TCP
260 mm
TCP
ZF
Tool A
260mm
TCP
ZF
Tool B
145mm
Tool C
In case of Tool A, B
In case of Tool C
8-22
RE-CTO-A220
165292-1CD
DX200 Controller
8.3.1.3
8 System Setup
8.3 Tool Data Setting
Flange
coordinates
XF
YF
XT
ZF
Tool
coordinates
YT
ZT
YF
ZF
X F
Rz = 180
8-23
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
6. Press [ENTER].
The rotation angle of Rz is registered.
In the same way, register the angle of Ry, Rx.
Ry must be the input rotation angle around YF flange coordinates.
X F
ZF
Y F (Y F )
Z F
Ry = 90
YF
Z F
8.3.1.4
Rx = 0
SUPPLEMENT
8-24
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
8.3.2
8.3.2.1
Tool Calibration
Tool Calibration
To ensure that the manipulator can perform motion type operations such
as linear and circular motion type correctly, accurate dimensional
information on tools such as torches, tools, and guns must be registered
and the position of the TCP must be defined.
Tool calibration is a function that enables this dimensional information to
be registered easily and accurately. When this function is used, the TCP is
automatically calculated and registered in the tool file.
What is registered in tool calibration is the coordinates of the TCP and the
tool posture data in the flange coordinates.
XF
Flange
coordinates
ZF
<Flange coordinates>
XF: Vertically upward direction when the current
position on the T-axis of the manipulator is "0"
YF: Y-axis complementing XF and ZF
ZF: Direction perpendicular to the flange face
XT
YT
YF
Tool
coordinates
8.3.2.2
ZT
8-25
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
NOTE
8.3.2.3
TC3
TC4
TCP
TC5
8-26
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
TOOL
TCP
YT
XT
ZT
X
TC1
TC4
TC3
TC5
SUPPLEMENT
TC2
TC1
TC4
TC3
TC5
[S2C432 = 0 or 2 ]
[S2C432 = 1 ]
8-27
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
SUPPLEMENT
8-28
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
5. Select {CALIBRATION}.
The TOOL CALIBRATION window is shown.
8-29
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
7. Select POSITION.
The selection dialog box is shown.
(1)
8-30
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
10. Select COMPLETE.
Calibration data is registered in the tool file. Once the calibration is
completed, the tool coordinate window is displayed on the screen.
8-31
RE-CTO-A220
165292-1CD
DX200 Controller
8.3.2.4
8 System Setup
8.3 Tool Data Setting
8-32
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
3. Select {YES}.
All data is cleared.
SUPPLEMENT
8-33
RE-CTO-A220
165292-1CD
DX200 Controller
8.3.2.5
8 System Setup
8.3 Tool Data Setting
Tool center
point
1. Press [COORD].
Select any coordinate system except
[COORD].
JOINT by pressing
8-34
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
3. Move the R, B, or T axes using the axis key.
By pressing the axis keys for the R, B, and T axes, change the
manipulator pose without changing the TCP position.
If this operation shows a large TCP error, adjust the tool data.
TCP
SUPPLEMENT
8-35
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
8.3.3
8.3.3.1
What is the Automatic Measurement of the Tool Load and the Center of Gravity?
With this function, the user can register the load of tool and the position of
the tools center of gravity.
The tool load and the position of its center of gravity are measured and
registered in a tool file.
NOTE
8.3.3.2
U+
R-axis
B-axis
B+
T-axis
UL-axis
T+
B-
T-
Home Position
(Horizontal to the U-,
B- and R-axes)
NOTE
8-36
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
1. Select {ROBOT} under the main menu.
2. Select {TOOL}.
The tool list window appears.
The tool list window is called up only when the file extension function
is valid.
If the file extension function is invalid, the tool coordinate window appears.
8-37
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
3. Select the desired tool number.
Move the cursor to the desired number in the tool list window and
press [SELECT].
The tool coordinate window of the selected number is shown.
In the tool coordinate window, the number can be changed by
pressing the [PAGE] or selecting [PAGE].
To switch the tool list window and the tool coordinate window, press
{DISPLAY} {LIST} or {DISPLAY} {COORDINATE DATA}.
8-38
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
5. Select {W.GRAV.POS MEASURE}.
The window for the automatic measurement of the tool load and the
center of gravity is shown.
SUPPLEMENT
8-39
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.3 Tool Data Setting
When all the measurements are completed or when all the
marks have changed into , the measured data appears on the
screen.
9. Select REGISTER.
The measured data is registered in the tool file, and the tool
coordinate window appears.
Select CANCEL to call up the tool list window without registering
the measured data in the tool file.
8-40
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
8.4
8.4.1
ARM Control
ARM Control
ARM Control, a control system originally developed by Yaskawa, achieves
an enhanced robot motion performance such as improved path accuracy
or reduced cycle time.
The moment of inertia and the gravity moment etc. of each axis are
calculated by the ARM control function, and DX200 controls robot motion
according to the result. It is necessary to set the robot setup condition and
the tool load information to request these accurately.
The robot setup condition is robot installation angle relative to ground and
the weight and a center of gravity position of the load installed at each part
of robot, etc.
The tool load information is weight, a center of gravity position, and
moment of inertia at the center of gravity, of the tool installed at the flange.
It is necessary to set these information correctly to do a better operation
control by the ARM control.
8.4.2
CAUTION
8-41
RE-CTO-A220
165292-1CD
DX200 Controller
8.4.2.1
8 System Setup
8.4 ARM Control
<Example>
0 degrees
-90 degrees
+90 degrees
180 degrees
If the robot installation angle is not correctly set, the manipulator cannot be
properly controlled. Therefore, make sure to set the value correctly,
paying special attentions to the direction + or -.
NOTE
8-42
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
S-head payload
Set the weight and the center of gravity position roughly when the
equipment such as transformer is installed at the S-head.
It is not necessary to set these values when there is no installed load on
the S-head.
WEIGHT (unit: kg)
The weight of the installed load is set.
It is not required to set a correct value, however, it is recommended to set
a value slightly larger than the actual load. (Round up the value with each
fraction between 0.5 to 1 kg.)
X (From S-Axis), Y (From S-Axis) (unit: mm)
The center of gravity position of the installed load is set by the distance in
the direction of X and the direction of Y from S axis center here. It can be
set with a rough value.
The direction of X and Y applies to the robot coordinates. The value is set
by a negative number when the position is in - direction.
Load on the S-head (Top View)
-X
S axis center
-Y
+Y
(X position, Y position)
+X
U-arm payload
Set the weight and the center of gravity position roughly when the
equipment such as the wire supplying motors is installed on U arm.
A standard value is set when shipping from the factory.
Set the weight in 0 if there is no installing equipment on U arm.
WEIGHT (unit: kg)
The weight of the installing load is set here.
Set a little large value though it does not care by a rough value. (Rase to
a unit in each 0.5 to 1kg)
X (From U-Axis), HEIGHT (From U-Axis) (unit: mm)
The center of gravity position of the installing load is set here. It does not
care by a rough value.
8-43
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
X (From U-Axis) is horizontal distance from U axis rotation center to the
center of gravity position of the load. Set negative number when there is
mass side in the back from U-axis rotation center.
HEIGHT (From U-Axis) is height of the vertical direction from U-axis
rotation center to the center of gravity position of the load.
Fig. 8-1: Load on the U-arm: Center of Gravity Position (Side View)
X (From U-Axis)
(-)
U-axis
rotation
center
(+)
Center of Gravity
Position
HEIGHT
(From U-Axis)
NOTE
8-44
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
1. Select {ROBOT} under the main menu.
GO
BACK
PAGE
, or select [PAGE].
Select the desired control group when there are two or more group
axes.
8-45
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
8.4.3
CAUTION
The speed reducer longevity might decrease or the alarm might occur
when the tool load information is not set correctly.
To set the tool load information correctly, following message appears
when inputting the information.
Input correct tool information. Using robot with wrong tool information
may result in premature failure of the robot.
Confirm the operation path of robot of each job which uses the tool
file after the tool load information is changed.
Set the tool load information before teaching the job after the tool is
installed.
Confirm the operation path of each job which uses the tool file when the
tool load information should be modified after teaching.
Modifying the tool load information may slightly change the operation
path. To avoid injury or damage to machinery caused by collision
between tool and positioner, make sure to check the operation path
before executing a job.
8.4.3.1
XF'
XF
Ix
YF'
Iy
YF
ZF'
Iz
Weight:W
ZF
* Flange Coodinates
XF: It is a direction right above when T axis
is 0 pulse position and the flange surface
of the manipulator turned to the front.
YF: Y axis led by XF,ZF
ZF: Perpendicular direction from flange surface
8-46
RE-CTO-A220
165292-1CD
DX200 Controller
8.4.3.2
8 System Setup
8.4 ARM Control
8-47
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
Rough value of the moment of inertia at the center of gravity can be
calculated by the following methods.
Method to approximate the entire tool in hexahedron or cylinder.
Method to calculate from each weight and center of gravity position
of plural mass.
Refer to the following setting examples for details.
<Example 1>
In the example of sealing gun of the figure below, the center of gravity is
set on the flange coordinates assuming that the center of gravity is
positioned slightly inclined to the head from the center.
There is no need to set the moment of inertia at the center of gravity since
the size of the gun is not too large.
<Setting>
YF
XF
Total Weight
Approx. 6.3 [kg]
7.00 [kg]
7.000 kg
Xg
: 100.000 mm
Yg
0.000 mm
Zg
70.000 mm
Ix
0.000 kg m2
Iy
0.000 kg m2
Iz
0.000 kg m2
100
ZF
Z
Ly
Lx
Iz
Iz
SUPPLEMENT
Iy
Lz
Ix
Iy =
Iz =
Ly + Lz
Weight: W
12
Lx 2 + Lz 2
12
Lx 2 + Ly 2
12
Iy
Ix
Weight:W
2
Ix =
*W
*W
*W
Ix = Iy =
Iz =
r
2
3 r + H2
12
*W
*W
8-48
RE-CTO-A220
165292-1CD
8 System Setup
8.4 ARM Control
<Example 2>
It is necessary to set the moment of inertia at the center of gravity when
the entire size of the tool and workpiece is large compared to the distance
from the flange to the center of gravity position.
Calculate the moment of inertia at the center of gravity roughly from the
expression (refer to the forementioned supplement: "The own moment of
inertia calculation for hexahedron and cylinder"), by approximating the
entire tool in the shape of the hexahedron or the cylinder.
If the weight of held workpiece is greatly different in the handling usage
etc., it is more effective to set tool load information on each workpiece and
to switch the tool on each step according to the held workpiece. Set the
tool load information in the state to hold the heaviest workpiece when
using the tools without switching them.
YF
500
XF
250
DX200 Controller
Weight of tool:
Approx. 55 kg.
ZF
Weight of workpiece:
Approx. 40 kg.
400
1000
Weight:
W = 55 + 40 = 95
= approx. 100[kg]
: 100.000 kg
Xg
0.000 mm
Yg
0.000 mm
Zg
: 250.000 mm
Ix
10.000 kg.m2
Iy
3.500 kg.m2
Iz
10.500 kg.m2
8-49
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
Icxi, Icyi, Iczi : Own moments of inertia of the i-th parts [kg*m2]
SUPPLEMENT
3. The center of gravity position of the entire tool is calculated by the next
expression.
xg = {w1 * x1 + w2 * x2 + .... + wi * xi} / (w1 + w2 + .... + wi)
yg = {w1 * y1 + w2 * y2 + .... + wi * yi} / (w1 + w2 + .... + wi)
zg = {w1 * z1 + w2 * z2 + .... + wi * zi} / (w1 + w2 + .... + wi)
4. The moment of inertia at the center of gravity position of the entire tool is
calculated by the next expression.
Ix = {w1 * ((y1 - yg)2 + (z1 - zg)2) * 10-6 + Icx1} + {w2 * ((y2 - yg)2 +
(z2 - zg)2) * 10-6 + Icx2}
...................
+ {wi * ((yi - yg)2 + (zi - zg)2) * 10-6 + Icxi}
Iy = {w1 * ((x1 - xg)2 + (z1 - zg)2) * 10-6 + Icy1} + {w2 * ((x2 - xg)2 +
(z2 - zg)2) * 10-6 + Icy2}
.....................
+ {wi * ((xi - xg)2 + (zi - zg)2) * 10-6 + Icyi}
Iz = {w1 * ((x1 - xg)2 + (y1 - yg)2) * 10-6 + Icz1} + {w2 * ((x2 - xg)2 +
(y2 - yg)2) * 10-6 + Icz
.....................
+ {wi * ((xi - xg)2 + (yi - yg)2) * 10-6 + Iczi}
8-50
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
<Example 3>
When there are two or more big mass such as the twin gun system as
shown in the figure below, perform:
1. Set the center of gravity position when the center of gravity position of
the entire tool is roughly understood, and set the moment of inertia at
the center of gravity calculated by approximating the entire tool in the
shape of hexahedron or cylinder. (It is enough in this setting usually.);
or
2. When weight in each mass and the center of gravity position are
understood, the center of gravity position and the moment of inertia at
the center of gravity of the entire tool can be calculated. (Refer to
forementioned supplement column: "How to calculate "Center of
gravity position" and "moment of inertia at the center of gravity" for
plural mass".)
This example shows the calculation with the method 2.
(Top View)
Center of Flange
YF
YF
100
XF
50
40
150
Gun 1
70
XF
(Gun 1)
Weight: w1 = 3 kg
Center of Gravity:
x1 = 100 mm
y1 = 50 mm
z1 = 40 mm
Gun 1
ZF
Gun 2
Weight :
Gun 2
(Gun 2)
Weight: w2 = 6 kg
Center of Gravity:
x2 = 100 mm
y2 = -150 mm
z2 = 70 mm
W = w1 + w2
= 3 + 6 = 9 = approx. 10[kg]
= 100.0 [mm]
= 60.0 [mm]
= 0.002
= approx. 0.010
8-51
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
Iz = 3 * ((100 - 100)2 + (50 - (-83))2) * 10-6
+
8.4.3.3
10.000 kg
Xg
: 100.000 mm
Yg
: -83.333 mm
Zg
Ix
60.000 mm
0.100 kg.m2
Iy
0.010 kg.m2
Iz
0.100 kg.m2
8-52
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
5. Press [ENTER].
The input value is registered.
The servo power is automatically turned OFF when editing the value
while the servo power is ON, followed by a message "Servo off by
changing data" displayed for three seconds.
8-53
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.4 ARM Control
NOTE
8-54
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.5 Work Home Position
8.5
8.5.1
8.5.2
8.5.2.1
8-55
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.5 Work Home Position
3. Press the [PAGE].
When two or more manipulators exist in the system, use the [PAGE]
to change the control group, or click on [PAGE] to select the desired
control group.
8-56
RE-CTO-A220
165292-1CD
DX200 Controller
8.5.2.2
8 System Setup
8.5 Work Home Position
NOTE
The work home position cube is a cube like the one shown
in the figure below; the length of its sides is determined by a
parameter setting made by the user (units: m).
By changing this parameter setting, the size of the cube
can be changed.
Fig. 8-2: S3C1097: The work home position cube length of
its sides (m)
a
a
2
2
2
8-57
RE-CTO-A220
165292-1CD
DX200 Controller
8.5.2.3
8 System Setup
8.5 Work Home Position
8.5.2.4
8-58
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
8.6
8.6.1
Interference Area
Interference Area
The interference area is a function that prevents interference between
multiple manipulators or the manipulator and peripheral device. The area
can be set up to 32 area. There are two types of interference areas, as
follows:
Cubic Interference Area
Axis Interference Area
The DX200 judges whether the TCP of the manipulator is inside or outside
this area, and outputs this status as a signal.
8.6.2
8.6.2.1
Robot coordinate
Z-axis
Cubic
interference
area
Cubic
interference
area
User Coordinates
Z-axis
Y-axis
X-axis
Y-axis
X-axis
8-59
RE-CTO-A220
165292-1CD
DX200 Controller
8.6.2.2
8 System Setup
8.6 Interference Area
Z-axis
Maximum
value
Cubic
interference
area axis
X-axis
Minimum
value
Y-axis
Z-axis
Maximum
value
X-axis
Minimum
value
Y-axis
3. After entering the lengths of the three faces of the cube (axial length)
using the Numeric keys, move the manipulator to the center point of
the cube using the axis keys.
Center
point
Z-axis
X-axis
Y-axis
8-60
RE-CTO-A220
165292-1CD
DX200 Controller
8.6.2.3
8 System Setup
8.6 Interference Area
Setting Operation
1. Select {ROBOT} under the main menu.
2. Select {INTERFERENCE}.
The INTERFERENCE AREA window is shown.
8-61
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
3. Select the desired cube number.
Select the desired cube number with the [PAGE] or by number input.
When selecting the cube number by number input, select [PAGE] to
input the desired signal number.
4. Select METHOD.
AXIS INTERFERENCE and CUBIC INTERFERENCE are
displayed alternately every time [SELECT] is pressed. If CUBIC
INTERFERENCE is selected, the window is changed.
8-62
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
5. Select CONTROL GROUP.
A selection dialog box appears.
(1) Select the desired control group.
8-63
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
7. Select CHECK MEASURE.
NOTE
8-64
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
When selecting ON and if the manipulators TCP approaches
inside the pre-defined interference area, the following alarm occurs
and the manipulator stops immediately.
AL4902 CUBE INTERFERENCE (TCP)
2. Input number for MAX and MIN data and press [ENTER].
The cubic interference area is set.
8-65
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
Teaching Corner
1. Select METHOD.
(1) Each time [SELECT] is pressed, MAX/MIN and CENTER POS
switch alternately.
(2) Select MAX/MIN.
2. Press [MODIFY].
A message Teach max./min. position appears.
8-66
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
3. Move the cursor to <MAX> or <MIN>.
Move the cursor to <MAX> when changing the maximum value,
and move cursor to <MIN> when changing the minimum value.
The cursor only moves to either <MIN> or <MAX> at this time.
4. Move the manipulator using the axis keys.
Move the manipulator to the maximum or minimum position of the
cube using the axis keys.
5. Press [ENTER].
The cubic interference area is registered.
8-67
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
8-68
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
3. Press [MODIFY].
A message Move to center point and teach appears. The cursor
only moves to either <MIN> or <MAX> at this time.
8-69
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
8.6.3
8.6.3.1
ON
Min value
- side
OFF
8.6.3.2
Setting Operation
1. Select {ROBOT} under the main menu.
2. Select {INTERFERENCE}.
The INTERFERENCE AREA window appears.
8-70
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
3. Select the desired interference signal number.
Select the desired interference signal number using the [PAGE] or
by number input.
When selecting the desired interference signal number by number
input, select [PAGE] to input the desired signal number.
4. Select METHOD.
AXIS INTERFERENCE and CUBIC INTERFERENCE are
displayed alternately every time [SELECT] is pressed. Select AXIS
INTERFERENCE.
8-71
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
5. Select CONTROL GROUP.
A selection box appears. Select the desired control group.
8-72
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
7. Select ALARM OUTPUT.
8-73
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
8-74
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
Teaching Corner
1. Select METHOD.
(1) Each time [SELECT] is pressed, MAX/MIN and CENTER POS
switch alternately.
(2) Select MAX/MIN.
2. Press [MODIFY].
A message Teach max./min. position appears.
8-75
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
5. Press [ENTER].
The cubic interference area is registered.
8-76
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
8-77
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
3. Press [MODIFY].
A message Move to the center point and teach appears.
The cursor only moves to either <MIN> or <MAX> at this time.
8-78
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
8.6.4
8-79
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.6 Interference Area
5. Select {CLEAR DATA}.
The confirmation dialog box appears.
6. Select {YES}.
All the data of the interference signal number are cleared.
8-80
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
8.7
8.7.1
WARNING
This function does not completely avoid damage to the peripheral
devices; moreover, it does not guarantee the users safety.
Make sure to prepare the safety measures such as the safeguarding
etc. Refer to chapter 1 Safety at page 1-1 to chapter 6 Test of
Program Operation on page 6-1 for the safety measures in details.
Failure to observe this warning may result in Injury or damage to
machinery caused by contact with the manipulator.
8.7.2
8.7.2.1
8-81
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
The detection level is changed by a job instruction SHCKSET.
After the instruction is executed, the shock will be detected by the
specified detection level when the condition number is specified with
the SHCKSET instruction.
The detection level is returned to standard level when the SHCKRST
instruction is executed.
Setting in the specific section
in play mode
(Condition number 1 to 7)
Standard used
for play mode
(Condition
number 1 to 8)
Shock Detection
Level File
Condition number 1
Condition number 7
Condition number 8
Condition number 9
SUPPLEMENT
By using this function, the detection level can be set for each
axis.
S2C869: Teach Mode Each Axis Setting Function
(1: VALID, 0: INVALID)
8-82
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
2
3
4
5
Condition Number (1 to 9)
1 to 7: for changing detection level in play mode.
8: for standard detection level in play mode.
9: for detection level in teach mode.
Robot Select
Select the manipulator whose detection level is to be changed.
Function Select
Specifies VALID/INVALID of the shock detection function. The shock
detection function is specified for each manipulator.
1. Select the manipulator whose function is to be enabled or disabled.
3
Specifies the shock detection level. Set a value larger than the maximum disturbance force.
The value set by default (the level 100) enables the function without
false detection even if the manipulator is operated at the maximum
speed.
To change DETECT LEVEL, move the cursor to the subject
manipulator, and press [SELECT] to display the numeric input status;
input the value with a numeric key and press [ENTER]. To increase the
detection sensitivity, set the level to small value, and to decrease the
sensitivity, set the level to large value.
8-83
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
Enter 120 in the coefficient (%) by which the max. disturbance force
is multiplied.
The following calculated value A or B, whichever is larger, is set to
the DETECT LEVEL.
A: (Max. disturbance force) x (coefficient = 120%)
B: (Max. disturbance force) + 15
<Example>
When the max. disturbance force is 80, the DETECT LEVEL is 96.
When the max. disturbance force is 10, the DETECT LEVEL is 25.
8-84
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
4. Level setting for the condition number 9.
The level setting for the condition number 9 is for the teach mode.
This setting is made for each group.
Refer to the max. disturbance force to set the DETECT LEVEL.
NOTE
NOTE
8-85
RE-CTO-A220
165292-1CD
DX200 Controller
8.7.2.2
8 System Setup
8.7 Shock Detection Function
NOTE
NOTE
1
2
3
4
Robot Select
Select the manipulator to display the detection level.
Function Select
Displays the valid/invalid status of the shock detection function.
Detection Level
Displays the shock detection level.
When the maximum disturbance force exceeds this set value, the shock
is detected.
8-86
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
NOTE
8.7.2.3
8.7.2.4
8.7.2.5
SHCKSET instruction
The SHCKSET instruction changes the shock detection level to the value
set in the shock detection level file during play back operation.
The additional items of the SHCKSET instruction are as follows.
Robot Setting
Specifies the manipulator of which shock detection level is to be modified. If nothing is specified, the modification is applied to the shock
detection level of the job control group in this instruction. However, in
case of coordinated job, the modification is applied to the shock detection level of the slave axis group.
8-87
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
3
S-axis L-axis
If the non-existing axis in the system was specified to change the shock
detection level for each axis, the its specified shock detection level is
invalid.
SHCKRST instruction
The shock detection level changed by the SHCKSET instruction is reset
and returned to the detection level of the standard (value set in condition
number 8) by the SHCKRST instruction.
The additional item of the SHCKRST instruction is as follows.
SHCKRST R1
Robot Setting
Specifies the manipulator of which shock detection level is to be reset.
If nothing is specified, the modification will be applied to the shock
detection level of the job control group of this instruction. However, in
case of coordinated job, the modification is applied to the shock detection level of the slave axis group.
Instruction Registration
The instruction is registered when the cursor is in the address area in the
JOB CONTENT window in teach mode.
1. Select {JOB} under the main menu.
Address
Area
Instruction
2. Select {JOB}.
3. Move the cursor in the address area.
8-88
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
SHCKSET
1. Move the cursor to the immediately preceding line where the
SHCKSET instruction is to be registered.
2. Press [INFORM LIST].
The inform list dialog box is shown.
(2) Press [ENTER] to change the number in the input buffer line.
8-89
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
When the robot specification is added
(1) When the robot specification is added, move the cursor to the
instruction in the input buffer line and press [SELECT] to display
the DETAIL window.
8-90
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
When the shock detection level for the each axis change is
added
(1) Move the cursor over the instruction in the input buffer line, and
select [Select] to display the DETAIL EDIT window.
(3)
8-91
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
When changing the shock detection level for the each axis
(1) When changing the shock detection level for the each axis, move
the cursor to the shock detection level; hold down [SHIFT] and
press the up/down cursor key to change the level.
(2) Input the numbers, and then press [ENTER]. The value in the
input buffers is changed.
5. Press [INSERT] then [ENTER].
The instruction displayed in the input buffer line is registered.
SHCKRST
1. Move the cursor to the immediately preceding line where the
SHCKRST instruction is to be registered.
2. Press [INFORM LIST].
The inform list appears.
8-92
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
(1) When adding the robot specification, move the cursor to instruction in the input buffer line and press [SELECT] to display the
DETAIL window.
8-93
RE-CTO-A220
165292-1CD
DX200 Controller
8.7.2.6
8 System Setup
8.7 Shock Detection Function
The shock detection alarm in teach mode and play mode can be reset by
the following operation.
1. Press [SELECT].
The alarm is reset when RESET is selected on the alarm display,
and the shock detection status is released.
2. Operation after resetting the detection status.
In teach mode, the JOG operation of the manipulator is enabled by
resetting the status.
In the play mode, move the manipulator once to the safety position
in the teach mode to check the damage though the playback
operation is possible after resetting the status.
NOTE
8-94
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
8.7.3
WARNING
This function does not completely avoid damage to the peripheral
devices; moreover, it does not guarantee the users safety.
Make sure to prepare safety measures such as safeguarding etc.
Refer to chapter 1 Safety at page 1-1 to chapter 6 Test of Program
Operation on page 6-1 for the safety measures in details.
Failure to observe this warning may result in injury or damage to
machinery caused by contact with the manipulator.
8.7.3.1
8-95
RE-CTO-A220
165292-1CD
DX200 Controller
8.7.3.2
8 System Setup
8.7 Shock Detection Function
8.7.3.3
Reading the Tool Load Information on the MAKER INITIAL VALUE Window
1. Change the SECURITY MODE to the MANAGEMENT MODE, then
select {ROBOT} under the main menu.
2. Select {TOOL}.
The TOOL window appears.
3. Select the desired tool number.
4. Select {DATA} under the menu.
The pull-down menu appears.
8-96
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
5. Select {READING}.
The MAKER INITIAL VALUE window appears.
8-97
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
7. Select {YES}.
The tool load information is read into the tool file, and the TOOL
window appears.
When NO is selected, the tool load information is NOT read into
the tool file, and the TOOL window appears.
NOTE
NOTE
8-98
RE-CTO-A220
165292-1CD
DX200 Controller
NAME
The name of tool load information prepared by Yaskawa is indicated.
When using the tool in the following figure, select 300R BUILT MODEL,
308R BUILT MODEL, or 308RR UNIV MODEL.
397.7
(385.4)
395
325
(312.1)
8.7.3.4
8 System Setup
8.7 Shock Detection Function
40
35
15
15
31
(116.5)
82.5
125
NOTE
15
(74.8)
8-99
RE-CTO-A220
165292-1CD
DX200 Controller
8.7.3.5
8 System Setup
8.7 Shock Detection Function
8-100
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
4. Select {READING}.
The MAKER INITIAL VALUE window appears.
8-101
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.7 Shock Detection Function
6. Select {YES}.
The U-arm payload is read into the ARM CONTROL window, and
the ARM CONTROL window appears.
When {NO} is selected, the ARM CONTROL window appears
without the U-arm payload being read into the ARM CONTROL
window.
8-102
RE-CTO-A220
165292-1CD
DX200 Controller
8.7.3.6
8 System Setup
8.7 Shock Detection Function
NAME
The name of U-arm payload information prepared by Yaskawa is indicated.
When using the U-arm payload in the following figure, select from the
MAKER INITIAL VALUE window.
340MELC
310ELC
NOTE
340ELC
8-103
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.8 User Coordinate Setting
8.8
8.8.1
Z-axis
X-axis
XX
XY
Y-axis
ORG
NOTE
8-104
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.8 User Coordinate Setting
8.8.2
8.8.2.1
(2) The "" mark indicates that the user coordinates is completed to
set and the "" mark indicates that it is not completed.
(3) To check the position of the user coordinates select {DISPLAY}
{COORDINATE DATA}.
(4) The following window appears.
8-105
RE-CTO-A220
165292-1CD
DX200 Controller
8.8.2.2
8 System Setup
8.8 User Coordinate Setting
3. Move the manipulator to the desired position with the axis keys.
8-106
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.8 User Coordinate Setting
4. Press [MODIFY] then [ENTER].
Taught position is registered.
Repeat the steps 2 to 4 to teach ORG, XX and XY.
indicates that teaching is completed and "" indicates that it is
not completed.
8-107
RE-CTO-A220
165292-1CD
DX200 Controller
8.8.2.3
8 System Setup
8.8 User Coordinate Setting
3. Select {YES}.
All data is cleared.
8-108
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.9 Overrun/Tool Shock Sensor Releasing
8.9
CAUTION
To operate the manipulator with the overrun or shock sensor released,
pay extra attention to the safety of the surrounding operation
environment.
If the manipulator stops by overrun detection or tool shock sensor
detection, release the overrun or tool shock sensor by the following
procedure and reset the alarm and move the manipulator with the axis
keys.
1. Select {ROBOT} under the main menu.
2. Select {OVERRUN & S-SENSOR}.
The OVERRUN & SHOCK SENSOR window appears.
Select either "EMERGENCY STOP" or "HOLD" to set the item
"SHOCK SENSOR STOP COMMAND" which specifies the stop
condition in the current shock sensor detection.
E-STOP and HOLD are displayed alternately every time
[SELECT] is pressed.
8-109
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.9 Overrun/Tool Shock Sensor Releasing
3. Select RELEASE.
The control group in which overrun or shock sensor is detected is
indicated with ".
If RELEASE is selected, overrun or tool shock sensor is released
and CANCEL indication will be displayed.
NOTE
8-110
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.10 Soft Limit Release Function
8.10
NOTE
8-111
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.11 All Limit Release Function
8.11
CAUTION
To operate the manipulator with all limits released, pay extra attention
to ensure the safety of the surrounding operation environment.
Failure to observe this caution may result in injury or damage to
equipment due to the unexpected manipulator motion exceeding its
range of motion.
The following limits can be released with the All Limit Release function:
Limit Type
Contents
Mechanical Limit
L-U Interference
Cube Interference
NOTE
8-112
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.11 All Limit Release Function
1. Select {ROBOT} under the main menu.
2. Select {LIMIT RELEASE}.
The LIMIT RELEASE window appears.
8-113
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.12 Instruction Level Setting
8.12
8.12.1
8.12.1.1
Instruction Set
There are three instruction sets that can be used when registering the
instructions for the robot programming language (INFORM III): the subset
instruction set, the standard instruction set, and the expanded instruction
set.
Subset Instruction Set
The instructions displayed in the instruction list are limited to just those
that are most frequently used, reducing the number of instructions that
can be registered. Since few instructions are shown, selection and input
are simple.
Standard Instruction Set / Expanded Instruction Set
All the INFORM III instructions can be used. The number of additional
items to be used in each instruction differ in the standard instruction set
and expansion instruction set.
In the standard instruction set, the following functions cannot be used.
However, operation becomes easier because the number of data items
decreases when registering an instruction.
Use of local variables and arrangement variable
Use of variables for additional items (Example: MOVJ VJ = I000)
When instructions are executed, for example during playback, all the
instructions can be executed regardless of the instruction set used.
All instructions
Frequency used
instructions
Instruction set
8-114
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.12 Instruction Level Setting
8-115
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.12 Instruction Level Setting
3. Select LANGUAGE LEVEL.
The selection list appears.
8-116
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.12 Instruction Level Setting
8.12.3 Setting the Learning Function
The learning function is set at "VALID" by default.
1.
8-117
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.13 Setting the Controller Clock
8.13
8-118
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.14 Setting the Play Speed
8.14
8-119
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.14 Setting the Play Speed
4. Select JOINT or LNR/CIR.
The type of speed alternately changes from JOINT to LNR/CIR.
8-120
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
8.15
NOTE
Function
Description
Manufacturer
allocation
Instruction
allocation
Display allocation
8-121
RE-CTO-A220
165292-1CD
DX200 Controller
8.15.2.2
8 System Setup
8.15 Numeric Key Customize Function
Function
Description
Alternate output
allocation
Momentary output
allocation
Pulse output
allocation
Group output
allocation
(4-bit/8-bit)
Analog output
allocation
Analog incremental
output allocation
SUPPLEMENT
8-122
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
8.15.3 Allocating Operation
3. Select {DISPLAY}.
Pull-down menu appears.
To call up the KEY ALLOCATION (SIM) window, select {ALLOCATE
SIM. KEY}.
8-123
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
4. Select {ALLOCATE SIM. KEY}.
The KEY ALLOCATION (SIM) window appears.
In a system multiple applications, press the [PAGE] to change the
window to the allocation window for each application, or click on
[PAGE] to select the desired application number.
8.15.3.2
Instruction Allocation
1. Set this function in the KEY ALLOCATION (EACH) window. Move the
cursor to FUNCTION of the key to be allocated and press [SELECT].
Selection list appears.
2. Select INSTRUCTION.
The instruction is shown in the ALLOCATION CONTENT.
8-124
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
(1) To change the instruction, move the cursor to the instruction and
press [SELECT]. Then the instruction group list appears.
8-125
RE-CTO-A220
165292-1CD
DX200 Controller
8.15.3.3
8 System Setup
8.15 Numeric Key Customize Function
(1) To change the reserved job registration No. move the cursor to the
No. and press [SELECT]. Then input buffer line appears.
(2)
8-126
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
8-127
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
6. Press [INTERLOCK] and the allocated key at the same time.
A message Reserved display registered appears, and the window
is registered.
In this case, the CURRENT POSITION window is registered by
pressing [INTERLOCK] + [0] with the CURRENT POSITION window
displayed on the screen.
SUPPLEMENT
8-128
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
(1) To change the output No., move the cursor to the No. and press
[SELECT]. Then numeric value can be entered.
(2)
8-129
RE-CTO-A220
165292-1CD
DX200 Controller
8.15.3.6
8 System Setup
8.15 Numeric Key Customize Function
(1) To change the output No., move the cursor to the No. and press
[SELECT]. Then numeric value can be entered.
(2) Input the number to be changed, and press [ENTER].
8-130
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
(1) To change the output No. or output time, move the cursor to the
No. or time and press [SELECT]. Then numeric value can be
entered.
(2) Input the number or time to be changed, and press [ENTER].
8-131
RE-CTO-A220
165292-1CD
DX200 Controller
8.15.3.8
8 System Setup
8.15 Numeric Key Customize Function
(1) To change the output No. or output value, move the cursor to the
No. or value and press [SELECT]. Then numeric value can be
entered.
(2)
8.15.3.9
8-132
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
2. Select ANALOG OUTPUT.
The output port number and the output voltage value are displayed
in the ALLOCATION CONTENT.
(1) To change the output port No. or output voltage value, move the
cursor to the No. or voltage value and press [SELECT]. Then
numeric value can be entered.
(2)
8.15.3.10
(1) To change the output port No. or incremental value, move the cursor to the No. or incremental value and press [SELECT]. Then
numeric values can be entered.
(2)
8-133
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
8.15.4
Function
2. Move the cursor to the FUNCTION of the key that has been allocated
with I/O control with key allocation (SIM) and press [SELECT].
8-134
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
3. Select OUTPUT CONTROL INST.
The instruction corresponding to the I/O control allocated by key
allocation (SIM) is displayed in the ALLOCATION CONTENT.
8-135
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.15 Numeric Key Customize Function
8.15.5
8.15.5.1
Execution of Allocation
8.15.5.2
8.15.5.3
8.15.5.4
8-136
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.16 Changing the Output Status
8.16
NOTE
8-137
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.16 Changing the Output Status
4. Press [INTERLOCK] +[SELECT].
The output status is changed. (: status ON; : status OFF.)
SUPPLEMENT
8-138
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.17 Changing the Parameter Setting
8.17
Binary Data
Decimal Data
8-139
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.17 Changing the Parameter Setting
(1) Move the cursor to a parameter number and press [SELECT].
(2)
8-140
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.17 Changing the Parameter Setting
Set the parameters in the following manner.
1. Select the parameter data to be set.
(1) Move the cursor to the parameter number data (decimal or binary)
in the PARAMETER window, and press [SELECT].
(2)
(3)
3. Press [ENTER].
The new setting appears in the position where the cursor is located.
8-141
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.18 File Initialization
8.18
File Initialization
8.18.1
5. Select {JOB}.
A confirmation dialog box appears.
6. Select {YES}.
The job data is initialized.
When JOB is initialized, the following files are reset at the
same time.
Be careful when initializing JOB.
NOTE
User coordinates
Memory play file
Spot monitor data
Variable data
System definition parameter (S4D)
Robot calibration data
Conveyor calibration data
8-142
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.18 File Initialization
8.18.2 Initializing Data File
1. Turn ON the power supply again while pressing [MAIN MENU]
simultaneously.
2. Change the security mode to the management mode.
3. Select {FILE} under the main menu.
4. Select {INITIALIZE}.
5. Select {FILE/GENERAL DATA}.
The INITIALIZE window appears.
8-143
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.18 File Initialization
7. Press [ENTER].
A confirmation dialog box appears.
8. Select {YES}.
The selected data file/general data are initialized.
8-144
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.18 File Initialization
8.18.3 Initializing Parameter File
1. Turn ON the power supply again while pressing [MAIN MENU]
simultaneously.
2. Change the security mode to the management mode.
3. Select {FILE} under the Main Menu.
4. Select {INITIALIZE}.
5. Select {PARAMETER}.
The parameter selection window appears.
8-145
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.18 File Initialization
7. Press [ENTER].
A confirmation dialog box appears.
8. Select {YES}.
The selected parameter is initialized.
8-146
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.18 File Initialization
8.18.4 Initializing I/O Data
1. Turn ON the power supply again while pressing [MAIN MENU]
simultaneously.
2. Change the security mode to the management mode.
3. Select {FILE} under the main menu.
4. Select {INITIALIZE}.
5. Select {I/O DATA}.
The I/O data selection window appears.
8-147
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.18 File Initialization
7. Press [ENTER].
A confirmation dialog box appears.
8. Select {YES}.
The selected data is initialized.
8-148
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.18 File Initialization
8.18.5 Initializing System Data
1. Turn ON the power supply again while pressing [MAIN MENU]
simultaneously.
2. Change the security mode to the management mode.
3. Select {FILE} under the main menu.
4. Select {INITIALIZE}.
5. Select {SYSTEM DATA}.
The system data selection window appears.
8-149
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.18 File Initialization
7. Press [ENTER].
A confirmation dialog box appears.
8. Select {YES}.
The selected data is initialized.
8-150
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
8.19
Font Style
Small
Regular
Small
Bold
Regular
Regular
Regular
Bold
Large
Regular
Large
Bold
Extra large
Regular
Extra large
Bold
8-151
RE-CTO-A220
165292-1CD
DX200 Controller
8.19.1.3
8 System Setup
8.19 Display Setting Function
2. The font size setting dialog box appears on the center of the current
window.
8-152
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
To set the font size in the font size setting dialog box, follow the
procedure below.
1. Specify the font style.
The {Bold Type} check box can be checked or unchecked
alternately each time the check box is selected.
Check the {Bold Type} check box as follows to set the font to the bold
style.
Clear the {Bold Type} check box as follows to set the font to the
regular style.
8-153
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
3. The font size setting dialog box is closed, and the screen displays the
font specified in the dialog box.
8-154
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
To cancel the setting of the font size, follow the procedure below.
1. Select {Cancel} in the font size setting dialog box.
NOTE
Do not turn OFF the DX200 power supply when the font
size is being changed (when the font size setting dialog box
is on the screen).
8-155
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
8.19.2
8.19.2.1
8.19.2.2
Button Size
Font Style
Small
Regular
Bold
Regular
Regular
Bold
Large
Regular
Bold
8-156
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
The font size setting dialog box appears on the center of the current
window.
8-157
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
To set the button size in the button size setting dialog box, follow the
procedure below.
1. Specify the area to set the button size.
(1) Select the desired area from the area setting buttons.
(2) The buttons in the selected area is subject to size setting.
(3) Note that only the last-selected button determines the area subject
to size setting, even if settings are performed several times before
then.
Clear the {Bold Type} check box as follows to set the font to the
regular style.
8-158
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
3. Specify the button size.
Select a button from the three buttons in the dialog box.
4. The font size setting dialog box is closed, and the screen displays the
buttons specified in the dialog box.
The modification is applied only to the buttons in the area selected
with the area setting button. (In this example, the change is applied
only to the pull-down menu buttons in the menu area.)
8-159
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
To cancel the setting of the button size, follow the procedure below.
1.
NOTE
Do not turn OFF the DX200 power supply when the button
size is being changed (when the button size setting dialog
box is on the screen, or when an hourglass is indicated in
the middle of the screen).
8-160
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
8.19.3 Initialization of Screen Layout
The font/button size changed with the font/button size setting function can
be collectively changed back to the regular size.
8-161
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
The dialog box is closed, and the font/button sizes are collectively
changed to the regular size.
8-162
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.19 Display Setting Function
The dialog box closes without changing the current screen layout.
NOTE
Do not turn OFF the DX200 power supply when the screen
layout is being initialized (when the confirmation dialog box
is on the screen, or when an hourglass is indicated in the
middle of the screen).
8-163
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.20 Encoder Back-up Error Recovery Function
8.20
8.20.1
8.20.2
8-164
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.20 Encoder Back-up Error Recovery Function
7. Select {UTILITY} in the menu.
The pull-down menu appears.
8-165
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.20 Encoder Back-up Error Recovery Function
10. Select {YES}.
The absolute data of the selected axis is recovered.
Select {NO} to cancel the operation.
11. Select the current position.
To display the current position window, refer to DX200
MAINTENANCE MANUAL section 7.8.1 Current Position Window.
12. Confirm the current position.
Confirm the recovered current position, and modify the followings
depending on its values.
(1) The pulse number is approximately 0.
Recovered normally.
(2) The pulse number is approximately 4096.
Move the recovered axis to the 4096 pulse position, and register
the individual axis to calibrate the home position.
(3) The pulse number is approximately -4096.
Move the recovered axis to the -4096 pulse position, and register
the individual axis to calibrate the home position.
As for the registering the individual axis, refer to DX200
INSTRUCTION section 8.1.2 Calibrating Operation on page 85.
8-166
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8.21
NOTE
8-167
RE-CTO-A220
165292-1CD
DX200 Controller
8.21.2.1
8 System Setup
8.21 Preventive Maintenance Function
Outline
This function calculates the torque and the speed of the each axis during
the job operation, and diagnoses the time to replace the speed reducer by
the lifetime calculation. The replacement time is informed by displaying
the message and turning the replacement signal ON.
Operating the job in the play mode performs the diagnosis automatically.
NOTE
This function is only available for the robot axes. As for the
external axes, this function is not available.
8-168
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
5. Select {=SETUP CONDITION}.
The condition setup window is appears.
8-169
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8-170
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
4. Move the cursor over the =WARNING to invalidate the desired axis,
and select [Select]. [Invalid] and [Valid] will alternate each time when
press the [Select].
8-171
RE-CTO-A220
165292-1CD
DX200 Controller
8.21.2.2
8 System Setup
8.21 Preventive Maintenance Function
Diagnosis Element
Monitors the torque waveform during the job operation, and calculates the
average value of the vibration amplitude by extracting the waveform from
the torque arising from the speed reducer. This data is called the torque
average value, and it is the basis data to diagnose the lifetime. The
following chart shows the lifetime curved line according to the torque
average value and the operation hours.
Failure
Started operation
Lifetime curved line
Running in
Normal operation
Deterioration
Operation hours
Torque
Speed
Torque
Speed
8-172
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
By operating a job in the play mode, a data (the torque element arising
from the deterioration of the speed reducer) for each axis is recorded
automatically on a daily basis, and the data is accumulated.
When the difference value between the latest value the average value
from the measured result of the five days (the initial value) including the
day to diagnose and the average value the average of 30 days (the initial
value) between prior to 60 days from the day to diagnose and prior to 90
days from the day to diagnose becomes the threshold value or more, it
determines the speed reducer is almost failure, and outputs the warning.
The average value is indicated with%, and 100% indicates the standard
torque.
Prior to 90 days
A day to diagnose
Prior to 60 days
8-173
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
Setting Procedures
The setting procedures are described as follows.
1. Change the security mode to the management mode.
2. Select {=RM} in the main menu.
3. Select {=RM(REDUCER)}.
The lifetime calculation window appears.
8-174
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
5. Select {=SETUP CONDITION}.
The setup window appears.
Modify the condition as necessary.
1
3
4
5
6
7
8
9
8-175
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
=CALCULATION DAYS
Set the period to calculate the average value. The initial value of this item
is 30 (days).
=ELAPSED DAYS FROM CALC. START
Set the period to calculate the average value from the day to diagnose.
The initial value of this item is 60 (days).
=LATEST MEASURED DAYS
Set the period to calculate the latest value. The initial value of this item is
5 (days).
=ERROR DELETE FILTER
Use to delete the error when calculate the average value. The following
values (torque average) are excepted from the calculation of the average
value.
The average from the previous day exists.
The average from the previous day / any measurement value of the
average period100 > filter setting value
The any measurement value of the average period / the average
from the previous day100 > filter setting value
The average from the previous day does not exist.
The latest value / any measurement value of the average
period100 > filter setting value
The any measurement value of the average period / the latest
value100 > filter setting value
The initial value of this item is 200 (%).
=GRAPH NAME
Able to register the name of the graph.
=REPLACEMENT SIGNAL
Use this item to calculate the lifetime. Refer to Set the Replacement
Notice Signal at page 8-165.
NOTE
Even though the initial value is set, the accuracy of the life
diagnosis is not guaranteed performance.
8-176
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
Data Confirmation
By operating a job in the play mode, a data (the torque element arising
from the deterioration of the speed reducer) for each axis is recorded
automatically on a daily basis, and the data is accumulated. It is
unnecessary to prepare the job for this diagnosis.
Able to refer the data by following procedures.
1. Select {=RM} in the main menu.
2. Select {=RM(REDUCER)}.
3. Select {Display}.
The pull down menu appears.
1
2
3
SUPPLEMENT
8-177
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
Each item on the screen represents the following description.
=NG COUNT (IN A ROW)
Shows the number of the variation days, which is higher than the value of
the torque variation HIGH. The warning output signal, which is set by
=ACCEPT RATE HIGH, is turned ON when the number of the day above is
more than the number of the consecutive accept NG days.
=NG COUNT (ACCUM.)
Shows the total number of the variation days, which is higher than the
value of the torque variation HIGH. The number of =NG COUNT (IN A
ROW) is reset as 0, when a day does not exceed the torque variation.
However, this =NG COUNT (ACCM.) will not be reset.
=MEASURED DATE
Shows the date of the measurement or the updated speed reducer
diagnosis database.
=MEAS.
Shows the measured torque average.
=AVE.
Shows the arithmetic mean of the average period (certain number of the
days, which is calculated in the past, based on the MEASURED DATE).
However, the measured values excepted in the =ERROR DELETE
FILTER are not included.
=VARIATION (The Determining Value)
Shows the difference value between the latest value and the average
value. When this value exceeds the value, which is set at the torque
variation, it is determined as accept NG.
=LATEST
Shows the arithmetic mean of the latest period (certain number of the
days included the measured day).
=WARNING
Select this item to invalidate the warning output signal. [Invalid] and
[Valid] will alternate each time when press the [Select].
=RESET
Select this item after replacement of the speed reducer. The warning
output signal will be turned OFF, and the old data will not be used for the
lifetime diagnosis.
8-178
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8-179
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
Graph Display
Able to confirm the variation by a graph after the measurement. The
graph is updated every 24 hours automatically. The measured value and
changes of the variation can be displayed on the programming pendant.
Thus, able to confirm the changes of the torque visually. Use the graph
display as the one of the methods to determine the duration of life for the
speed reducer.
The graph can be displayed by the following procedures.
1. Select {=RM} in the main menu.
2. Select {=RM(REDUCER)}.
3. Select {Display}.
The pull down menu appears.
4. Select {=GRAPH}.
The graph appears.
3
4
5
2
8
9
10
5. Select {CLOSE}.
Return to the lifetime calculation window.
8-180
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
In the case of the graph above, it shows a variation > Lo of the T-axis,
and the warning output signal, which is set by torque variation low, is
ON.
When selecting =Meas.,
the measured value is displayed on the graph.
8-181
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
=Group
Select {=Group}, and the pull down menu appears. Select the group to
display.
=Name
The names set in the each setting window are displayed.
=Renew
Pressing the =Renew button updates the latest data.
=Days
Set the number of the days between 5 and 150 days to be displayed. The
latest data is displayed on the right side of the graph, and the old data set
by =Days is displayed on the left side of the graph.
=Torque
The minimum value and the maximum value of the vertical axis can be
set. MIN is the minimum value, and MAX is the maximum value.
=Axis
Removing the tick in the box hides the axis on the screen.
=Save CSV
Pressing the CSV button saves the variation and measured value into
the external memory device as CSV format. As for the external device, it
can be saved into both CF card and USB, but the data is priory save into
the CF card. The followings are the name for a file and a folder to be
saved.
File name: the name which is set in the each setting window + year/
month/day + hour/minute/second. CSV
Folder name: SR LIFE DIAGNOSIS
8-182
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
=Hard COPY
Pressing the =Hard COPY button saves the hard copy of the screen as
JPG format into the CF card.
The following is a name for the file.
File name: year/month/day + hour/minute/second. JPG
=CLOSE
Pressing =CLOSE button closes the graph window.
8-183
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
5. Move the cursor over the Reset on the axis window of which speed
reducer is replaced, and press {Select}.
The confirmation dialog appears.
6. Select Yes.
The data of its axis is reset, and the replacement day is recorded
into the =INSPECTION RECORD window.
The operation is cancelled when select No.
The procedures above can be performed in the lifetime window or the
torque monitor window.
The replacement day is recorded into the INSPECTION RECORD
window by performing the procedures above.
8.21.3
8-184
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8-185
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
6. Move the cursor over the =INSPECTION SIGNAL, and select.
It becomes the numeric value input status.
8-186
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
NOTE
8-187
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8.21.4
8-188
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8.21.5 Management of the Data
According to the torque average value, such as the speed reducer
preventive maintenance data base, the preventive maintenance elements,
the record of the inspection and replacement, can be loaded/saved by the
external memory device.
As for the external device menu, refer to Chapter 7 External Memory
Devices of DX200 OPERATORS MANUAL for more details.
1. Select {External memory} in the main menu.
The external memory menu window appears.
8-189
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
3. Select the {System data}.
The system data selection window appears.
(The following is an example of a window.)
8-190
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8.21.6 Preventive Maintenance for the Hardware
This function estimates the life span of the controller components by
calculating the consumed amount with considering the usage environment
and the load, and outputs general signals to be the reference for the
replacement time.
The function overview is described below.
Judgement
display
Status
8-191
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8.21.6.3
Replacement of Component
8-192
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8.21.7 Setting of Preventive Maintenance for the Hardware
8-193
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
3. Input the numerical value of the alarm signal.
When any of components in this controller comes to the replacement
time, the general output signal which is already set turns ON.
8-194
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
5. The following information is displayed:
Starting from the left,
(1) is displayed when the replacement time is judged as D.
(2) Component name
(3) General output signal valid/invalid
(4) The first day of use
(5) Leftover life judgement
When {COOLING FAN} is selected:
(1
(2
(3
(4
(5
8-195
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
When {CONTACTOR} is selected:
8-196
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8. When manually setting the approximate value to the leftover life, input
the numerical value 0 - 100%.
8-197
RE-CTO-A220
165292-1CD
DX200 Controller
8.21.7.2
8 System Setup
8.21 Preventive Maintenance Function
8-198
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
3. The general output signal turns OFF. And the message turns to be
hidden. However, the stepwise display remains D.
8-199
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8.21.8
8.21.8.1
8.21.8.2
8-200
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.21 Preventive Maintenance Function
8-201
RE-CTO-A220
165292-1CD
DX200 Controller
8.21.8.4
8 System Setup
8.21 Preventive Maintenance Function
1. Select the number of the axis to be reset by moving the cursor to it,
and then set the number.
To set the day of the first use (BEGINNING), select the date of the axis
to be reset by moving the cursor to it, and then set the date.
8-202
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.22 Break Line Ground Judgement Function
8.22
8-203
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.22 Break Line Ground Judgement Function
8.22.3
8.22.3.1
Operation
8-204
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.22 Break Line Ground Judgement Function
2. Press YES.
The confirmation dialog appears due to prevent the mis-operation.
Select YES, then the break line ground check appears.
Select NO, the window returns to the previous window.
8-205
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.22 Break Line Ground Judgement Function
3. Move the cursor over the axis to perform the break line ground check,
and press [SERVO ON READY]. Grip the enable switch and long
press [SELECT] while pressing down the [INTER LOCK] to perform
the break line ground check.
Perform the break line ground check to the every single axis
displayed on the screen.
The break line ground check is cancelled in the case of following
conditions.
[SELECT] is detached.
The emergency button of the programming pendant, controller or
external signal is pressed.
The servo power is disconnected by the servo power supply
individual control function.
The servo alarm occurs.
8-206
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.22 Break Line Ground Judgement Function
4. Detecting the Break Line Ground Fault
When the break line ground fault or the short circuit is detected, the
alarm 1694 GROUND FAULT (BRAKE LINE) occurs.
Inspect the break line of the axis which raised the alarm.
Restart the control power, and perform the break line ground check
to the rest of the axes.
8.22.3.3
8-207
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.22 Break Line Ground Judgement Function
3. Select {CLEAR}.
The confirmation dialog appears.
4. Press YES.
The related information of the break line ground check is initialized.
{BREAK LINE GROUND CHECK} does not appear in the {Main
Menu} until the alarm 1683 DC24V POWER SUPPLY
FAILURE(SV) occurs.
8-208
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8.23
8.23.1 Outline
The safety logic circuit is a function to create the safety logic circuit on the
programming pendant. It enables to set up the logical operations, such
as stopping the manipulator and outputting the servo ON signal.
The followings are the contents of this function.
(1) Executes the safety logic circuit by the machine safety logic circuit
board (type:YSF21-E) corresponded to the secure authentication.
(2) The safety logic circuit is composed by two inputs and one output
circuits, and can be set up the up to 128 circuits.
(3) The safety logic circuit is operated every 4 ms cycle.
(4) The safety logic circuit is referred by the all modes regardless the
security mode, and it can be edit only when the security mode is
higher than SAFETY MODE plus under the teach mode and the
servo is OFF.
(5) By using this safety logic circuit function, the hard-wired connection is no longer need to create the circuit, and becomes less wiring.
8-209
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8.23.2
8.23.2.1
8-210
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
Enter the password for the safety mode, and then press [ENTER].
8-211
RE-CTO-A220
165292-1CD
DX200 Controller
8.23.2.2
8 System Setup
8.23 Safety Logic Circuit
8-212
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
3. Canceling the edit
To start over the editing, select {CANCEL EDIT} from {EDIT} in the
pull-down menu.
8-213
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
Press YES, and then the file is updated.
The file transferred to the machine safety circuit board
(type:YSF21-E) is written in the FLASH ROM.
The status becomes DONE from NOT DONE.
If press NO, the file will not be updated. The status remains NOT
DONE.
NOTE
NOTE
8-214
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8-215
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8-216
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
4. Transferring or updating the file
After editing, select {WRITE} button.
The file is transferred to the machine safety circuit board
(type:YSF21-E). When the file transfer is done correctly, the
confirmation dialog Update the file? appears.
If press NO, the file will not be updated. The status remains NOT
DONE.
8-217
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
NOTE
NOTE
8-218
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
Output
500msec
ON DELAY time
Output
300msec
OFF DELAY time
8-219
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
1. Displaying the window.
Select {TIMER DELAY} from {SAFETY FUNC.} in the main menu.
8-220
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
3. Canceling the edit
To start over the editing, select {CANCEL EDIT} from {EDIT} in the
pull-down menu.
8-221
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
Press YES, and then the file is updated.
The file transferred to the machine safety circuit board (type:YSF21E) is written in the FLASH ROM.
The status becomes DONE from NOT DONE.
If press NO, the file will not be updated. The status remains NOT
DONE.
NOTE
NOTE
8-222
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8-223
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
After the setting, the status changes from DONE to NOT DONE.
The WRITE button is displayed on the left down corner of the
screen.
8-224
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
4. Line clear
To clear the one line, select {LINE CLEAR} from {EDIT} in the pulldown menu.
8-225
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
6. Copy
Choose the desired area to make a copy, and select {COPY} from
{EDIT} in the pull-down menu.
8-226
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
7. Transferring or updating the file
After editing, select {WRITE} button.
If there is a blank line in the safety logic board, it will be filled
automatically.
The file is transferred to the machine safety circuit board
(type:YSF21-E). When the file transfer is done correctly, the
confirmation dialog Update the file? appears.
If press NO, the file will not be updated. The status remains NOT
DONE.
8-227
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
NOTE
NOTE
8-228
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
No.
Signal Name
Abbreviation
Logic
OFF(0)
Note
ON (1)
Play mode
PLAY
Play mode
Teach mode
TEACH
Not teach
mode
Teach mode
Not under
emergency
stop
[Short circuit]
Under
emergency
stop
(Emergency
stop button is
pressed)
[Release]
Grip
[Short circuit]
Released
[Release]
Controller emergency
stop
PBESP
Not under
emergency
stop
[Short circuit]
Under
emergency
stop
(Emergency
stop button is
pressed)
[Release]
External emergency
stop
EXESP
Not under
emergency
stop
[Short circuit]
Under
emergency
stop
(Emergency
stop button is
pressed)
[Release]
External enable
switch
EXDSW
Grip
[Short circuit]
Released
[Release]
Safeguarding
SAFF
Close
[Short circuit]
Open
[Release]
Servo ON status
SVON
Servo OFF
Servo ON
10
GSIN1,
GSIN2
OFF
[Short circuit]
ON
[Release]
11
SFBIN1 to
SFBIN64
OFF
ON
12
Auxiliary relay
R1 to R128
OFF
ON
NOTE
8-229
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
Logic
The usable logical signals are shown below.
No. Signal Name
No.
Signal Name
Abbreviation
Logic OR
OR
Logic AND
AND
Note
Output Signal
The usable output signals are shown below.
Abbreviation
Logic
OFF(0)
Note
ON (1)
GSIN1,
GSIN2
OFF
ON
Manipulator stop
immediately
SVOFF CAT0
OFF
ON
Manipulator
deceleration to a stop
SVOFF CAT1
OFF
ON
SFBIN1 to
SFBIN64
OFF
ON
Auxiliary relay
R1 to R128
OFF
ON
NOTE
8-230
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
NOTE
NOTE
8-231
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
No.
Timer
Signal Name
Abbreviation
Note
ON delay timer1 to ON
delay timer4
TIMI1 ON DELAY ~
TIM4 ON DELAY
1. Turn ON the power of DX200 while pressing Main Menu key of the
programming pendant.
2. Select {SYSTEM} - {SECURITY} and change the security mode to the
safety mode.
3. Select {SYSTEM} - {SETTING} - {OPTION FUNCTION} - {Machine
Safety function}. Then the following window appears and the setting
change becomes possible.
8-232
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
Whether the universal input signals (signal name: GSIN1, 2) are used,
whether the universal output signals (signal name: GSOUT1, 2) are used,
and the polarity of the universal output signals can be set.
1. Select {DETAIL} of Machine Safety.
The DETAIL settings window of the machine safety function
appears. If the two or more YSF22 boards exist in the robot
coordinated specifications, press [PAGE] on the pendant and
perform the settings of the second pages and the later.
Polarity of GSOUT
Feedback signal
Output of GSOUT
signal
Synchronization is
performed
(SYNC.)
Synchronization is not
performed
(OUT OF SYNC.)
8-233
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
2. Press [ENTER].
The confirmation dialog box of parameter change appears.
3. Select {YES}.
If {YES} is selected, the system parameter is set automatically, and
then the OPTION FUNCTION window appears.
Feedback Signal
(1) With feedback signal connection
DX200
Machine Safety I/O
Logic Circuit Board
(JANCD-YSF22-E)
CN219
GSOUT1_1+
69
GSOUT1_1-
70
GSOUT1_2+
71
GSOUT1_2-
72
GSEDM1+
77
GSEDM1-
78
Dual Sianals
Safety Signal
Intaken as a feedback signal(*) of the devices driven by
the universal safety output signal(GSOUT) (safety relay,
contactor, etc.), and detects the wire sticking.
(*) It connects the contact B with forced guide nomally.
8-234
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
(2) Without feedback signal connection
DX200
Machine Safety I/O
Logic Circuit Board
(JANCD-YSF22-E)
CN219
GSOUT1_1+
69
GSOUT1_1-
70
GSOUT1_2+
71
GSOUT1_2-
72
GSEDM1+
77
GSEDM1-
78
Dual Sianals
DX200
Machine Safety I/O
Logic Circuit Board
(JANCD-YSF22-E)
CN219
GSOUT1_1+
69
GSOUT1_1-
70
GSOUT1_2+
71
GSOUT1_2-
72
GSEDM1+
77
GSEDM1-
78
Lamp
Universal output 1
8-235
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8.23.3
8-236
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8.23.4 Saving or Loading the File
8-237
RE-CTO-A220
165292-1CD
DX200 Controller
8.23.4.2
8 System Setup
8.23 Safety Logic Circuit
8-238
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
NOTE
When loading the safety logic circuit file, the file is not
transferred to the machine safety circuit board (type:
YSF21-E). Thus, perform {WRITE} in the one of the
following windows, such as {M-SAFETY SIGNAL ALLOC},
{TIMER DELAY SET}, {SAFETY LOGIC CIRCUIT} or
{SAFETY SIG. BOARD ALLOC}. The all display information
above are updated, and the file written in the FLASH ROM
of the machine safety circuit board is also updated.
8-239
RE-CTO-A220
165292-1CD
DX200 Controller
8.23.5.1
8 System Setup
8.23 Safety Logic Circuit
Enter the password for the safety mode, and press {ENTER}.
8-240
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
3. When the entered password is correct, the mode is changed to
{SAFETY MODE}. After changing to the safety mode, the icon
displayed on the status area.
is
8-241
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
5. Perform the initialization.
Select {ENTER}.
The confirmation dialog appears.
Select {YES}.
The file written in the FLASH ROM of the machine safety circuit
board (type: YSF21-E) is initialized.
8-242
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
NOTE
8-243
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8-244
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8.23.6 Example of Safety Logic Circuit
The followings are the examples of the safety logic circuit.
Signal 2:
Logic:
AND
ON
#1 GSIN1
OFF
#1 GSIN1: ON
ON
#1 GSIN2
OFF
#1 GSIN2: ON
ON
#1 GSOUT1
OFF
#1 GSIN1 and #1 GSIN2 are ON,
so that #1 GSOUT1 will be ON.
8-245
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
3. Verifying the safety logic circuit.
Switch ON the universal safety signal 1 and 2.
The mark becomes
.
8-246
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
<The safety logic circuit: example 2>
1. The emergency button of the programming pendant is pressed, and
the first universal input safety signal of the I/O circuit board
(type:YSF22 -E) 1 is OFF, and the I/O circuit board (type:YSF22 E) of the first universal output safety signal is ON after one second
passed.
Signal 1:
Signal 2:
Logic:
AND
ON
PPESP(press)
#1 GSIN1
OFF
GSIN1: OFF
NOT
#1 GSIN1
ON
OFF
NOT GSIN1: ON
Setting value
TM1 ON
DELAY
0
Timer (start)
ON
#1 GSOUT1
OFF
PPESP and NOT #1 GSIN1 are ON, and
ON DELAY TIM1 reached to the specified value
so that #1 GSOUT1will be ON
8-247
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
3. Verifying the safety logic circuit.
Confirm that the mark becomes when pressing the
programming pendant and switching the universal safety signal ON.
The mark of the universal safety output signal 1 becomes
after one second passed.
8-248
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
<The safety logic circuit: example 3>
1. When the first universal input safety signal of the I/O circuit board
(type:YSF22-E) 1 is ON (#1 GSIN1) and under the teaching mode,
the manipulator will decelerate and stop.
Signal 1:
Signal 2:
Logic:
AND
PLAY
NOT
#1 GSIN1
ON
OFF
#1 GSIN1: ON
ON
Decelerating
processing
OFF
Starts decelerating
processing
Ends decelerating
processing
ON
Servo ON
OFF
Under the teach mode and #1 GSIN1 is ON,
so that the servo will be turned ON after
the decelerating processing
8-249
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
3. Verifying the safety logic circuit.
Set up the teach mode, and turn the servo ON. When switching the
universal safety signal ON, the mark of the universal safety output
signal 1 becomes .
NOTE
8-250
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
<The safety logic circuit: example 4>
1. The setting example by using the auxiliary relay is described below.
When the any one of the status of the programming pendant
emergency stop, controller emergency stop or external emergency
stop is stopped, the first universal output safety signal 1 of the I/O
circuit board (type:YSF22 -E) is ON.
Signal 1:
Signal 2:
Signal 3:
Logic:
AND
ON(press)
P B ES P
OFF
(release)
ON
(release)
EX ES P
OFF
(short-circuit)
#1 G S O U T 1
8-251
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
3. Verifying the safety logic circuit.
When the one of the programming pendant emergency stop, controller
emergency stop or the external emergency stop is inputted, the mark
of the universal safety output signal 1 becomes .
8-252
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.23 Safety Logic Circuit
8.23.7 Alarm List of the Safety Logic Circuit
Alarm
Number
Sub-code Message
300
Remedy
Machine Safety board save data The safety logic circuit files in the file written in the Main
error
CPU circuit board (type: YCP21-E) and the machine
safety circuit board (type: YSF21-E) does not match.
Refer to section 8.23.5.2 Machine Safety Flash Data
Erase or Reset on page 8-243 for more details to
restore.
4776
4777
M-safety signal alloc information An alarm occurred while transferring the safety logic
transmission error was
circuit file to the machine safety circuit board
detected.
(type:YSF21-E). Reset the alarm, and re-send the
safety logic circuit file.
253
254
255
8-253
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.24 Robot Stop Factor Monitor Function
8.24
8.24.1
8.24.1.1
Table 8-1: The List of the Servo OFF Factors by Main CPU Instructions
Displayed Item
Secondary Indication
None
None
None
PARAMETER CHANGE
None
INST SVOFF
None
COMMAND SVON
None
None
None
None
TOOL CALIBLATION
None
ENCODER RESET
None
ROBOT DETACHMENT
None
None
None
None
SERVO ON ERROR
None
None
8-254
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.24 Robot Stop Factor Monitor Function
Table 8-2: The List of the Servo OFF Factors by Machine Safety Circuit Board Instructions
Displayed Item
Secondary Indication
PP EMERGENCY STOP
Programming pendant
emergency stop
PP ENABLE SWITCH
EXTERNAL EMERGENCY
STOP
EXTERNAL ENABLE
SWITCH
SAFETY FENCE
Safety guard
EXTERNAL SERVO ON
External servo ON
It is displayed only when the
level (S1D271=0) is specified
RDY0 OFF
RDY0OFF
Servo OFF request from the
main CPU
CATEGORY1 REQUEST
M3 COMMUNICATION
ERROR
Servo OFF by M3
communication error of the
main CPU or among the servo
circuit boards
CATEGORY0 SAFETY
LOGIC CIRCUIT
CATEGORY0 FUNCTION
SAFETY
CATEGORY1 SAFETY
LOGIC CIRCUIT
CATEGORY1 FUNCTION
SAFETY
YSF21 ALARM
CATEGORY0 STOP
CATEGORY1 STOP
OVER TRAVEL1
OVER TRAVEL2
OVER TRAVEL3
OVER TRAVEL4
8-255
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.24 Robot Stop Factor Monitor Function
Table 8-2: The List of the Servo OFF Factors by Machine Safety Circuit Board Instructions
Displayed Item
Secondary Indication
ON ENABLE1
ON ENABLE2
ON ENABLE3
ON ENABLE4
CATEGORY ON ENABLE1
CATEGORY ON ENABLE2
CATEGORY ON ENABLE3
CATEGORY ON ENABLE4
2ND CONTACTOR1
2NDSF1
The time of an auxiliary
contactor 1 in the secondary
contactor is up, and switch OFF
the servo of the machine safety.
2ND CONTACTOR2
2NDSF2
The time of an auxiliary
contactor 2 in the secondary
contactor is up, and switch OFF
the servo of the machine safety.
2ND CONTACTOR3
2NDSF3
The time of an auxiliary
contactor 3 in the secondary
contactor is up, and switch OFF
the servo of the machine safety.
2ND CONTACTOR4
2NDSF4
The time of an auxiliary
contactor 4 in the secondary
contactor is up, and switch OFF
the servo of the machine safety.
8-256
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.24 Robot Stop Factor Monitor Function
Secondary Indication
HOLD
None
None
INDIVIDUAL HOLD
None
None
None
HOLD (API)
None
None
Task number
TASK#0 to TASK#15
None
None
8-257
RE-CTO-A220
165292-1CD
DX200 Controller
8.24.1.2
8 System Setup
8.24 Robot Stop Factor Monitor Function
8.24.2
8.24.2.1
Operation
8-258
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.24 Robot Stop Factor Monitor Function
The following items are displayed on the RB STOP FACTOR
MONITOR window.
DETECT TIME: Shows the time when the robot stop factor was
detected.
The data on the first page is the latest one, and the page 20 is the
oldest data.
8-259
RE-CTO-A220
165292-1CD
DX200 Controller
8.24.2.2
8 System Setup
8.24 Robot Stop Factor Monitor Function
NOTE
8-260
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.25 Robot Detachment Function
8.25
8-261
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.25 Robot Detachment Function
3. Select {SECURITY}.
Mode selection screen is shown.
8-262
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.25 Robot Detachment Function
6. Input the password for safety mode and press [ENTER].
When the correct password is input, security mode is changed.
8-263
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.25 Robot Detachment Function
2. Select {SETUP}.
SETUP screen is shown.
8-264
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.25 Robot Detachment Function
5. Change the setting contents.
Move the cursor to the target group and select to change the setting.
Select ATTACHED or DETACHED.
8-265
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.25 Robot Detachment Function
7. Press [ENTER].
Confirmation message for parameter change is shown.
8-266
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.26 Axes Detachment Function
8.26
8.26.1 Outline
The axes detachment function is to invalid the connection of specific axes
by setting in maintenance mode. When the axes detachment function is
set, the system can be started without any alarm even if some axes are
not connected physically during setup or motor exchange.
8.26.2 Setting Maintenance Mode
Start the maintenance mode and set the security mode to the safety
mode. (Refer to section 8.25.1.)
8.26.3 Setting Axes Detachment Function
Operator can set or modify the setting items for axes detachment function
in detail setting screen.
The specified parameters are to be set automatically according to the
setting contents in detail setting screen.
1. Select {SYSTEM} under the main menu.
Sub menu is shown.
8-267
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.26 Axes Detachment Function
2. Select {SETUP}.
Setting selection screen is shown.
8-268
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.26 Axes Detachment Function
5. By pressing [PAGE], the target group for setting is switched.
7. Press [ENTER].
Confirmation message for parameter change is shown.
8-269
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.26 Axes Detachment Function
8. Select YES to confirm the change.
System parameters are to be set automatically, then the screen
returns to the option function screen.
8.26.4
8-270
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.26 Axes Detachment Function
8.26.5 Restrictions
1. Operation with restrictions
When the axes detachment function is set, the following operations are
restricted. If these operations are tried to be performed, an error or an
alarm occurs.
Playback
Test run
Job registration (insert/modify/delete jobs in the target control group)
Variable registration
Second home position registration
Home position registration
Work home position registration
SUPPLEMENT
Alarm
Playback
Test run
Job registration
(insertion, modification,
deletion)
Home position
registration
8-271
RE-CTO-A220
165292-1CD
DX200 Controller
8 System Setup
8.26 Axes Detachment Function
2. Operation without restrictions
CAUTION
While the axes detachment function is set, even if try to move the
manipulator to the taught position, the manipulator may not be
moved to the right position or operated in the right posture because
the specific axes dont operate. When performing the operations
mentioned below while the axes detachment function is set, be very
careful to the manipulators motion and the interference between
the manipulator and the peripheral devices.
8-272
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.1 System Backup with DX200
System Backup
For the DX200, the system data can be collectively backed up in advance
so that the data can be immediately loaded and restored in case of an
unexpected trouble such as data loss.
9.1
9.1.1
9.1.1.1
CMOS.BIN
For the normal backup, use this data.
Save: Perform in the normal or maintenance mode.
Load: Perform in the maintenance mode.
(the management mode or higher mode)
The loading/saving procedures in the maintenance mode,
refer to section 9.2 Backup by CMOS.BIN on page 9-3.
As for saving in the normal mode, refer to DX200 OPERATORS
MANUAL section 7.3.0.2 Saving Data .
Target Area: All areas of the internally stored data.
(Note that the monitoring time is not loaded.)
9.1.1.2
CMOSBK.BIN
This data is used in the automatic backup function.
Save: Saves with the preset conditions in the normal mode.
Load: Perform for the system restoration in the maintenance mode
(the management mode or higher mode)
For details, refer to section 9.3 Automatic Backup Function on page 9-7.
Target Area: All areas of the internally stored data.
(Note that the monitoring time is not loaded.)
9.1.2
Device
For the backup of the DX200 system, the CompactFlash or the USB
memory is used. (The USB slot of the programming pendant is not
available in the automatic backup function.)
The following tables show the recommended CompactFlash and USB
memory.
<Recommended CompactFlash>
No. Manufacturer
Model
Remarks
Hagiwara Solutions
MCF10P-256MS-YE
256MB
Hagiwara Solutions
MCF10P-512MS
512MB
Hagiwara Solutions
MCF10P-A01GS
1GB
Hagiwara Solutions
MCF10P-A02GS
2GB
9-1
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.1 System Backup with DX200
< Recommended USB Memory>
No. Manufacturer
1
Hagiwara Solutions
Model
Remarks
UDG4-xGDRJ
In order to save the batch data, the following free space per file is needed
in the media.
Approx. 26 MByte
Note that the free space for one working file is needed in addition to the
free space for the stored files when using the automatic backup function.
Also, it is recommended to store the backup data in two or more media
cards to minimize problems if the media is damaged.
The water-proof function of the Pendant is not effective
while the USB memory is connected.
NOTE
When using the USB memory, insert it in the USB slot of the CPU circuit
board. Be careful about the insertion direction of the connector: The USB
memory should be inserted slowly with the upper surface right. Forcible
insertion may cause the damage of the USB memory and the USB
connector.
USB memory
9-2
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.2 Backup by CMOS.BIN
9.2
Backup by CMOS.BIN
Perform the backup by CMOS.BIN in the normal or maintenance mode.
The chart below shows the availability of CMOS save/CMOS load in each
security mode in the maintenance mode.
9.2.1
Security
CMOS Save
CMOS Load
Operation Mode
Editing Mode
Management Mode
Safety Mode
CMOS.BIN Save
Follow the procedures below to save CMOS.BIN in the maintenance
mode.
1. Turn ON the DX200 power supply while pressing [MAIN MENU].
2. Insert a CompactFlash into the CompactFlash slot on the
programming pendant.
when USB memory is used instead of CompactFlash, mount USB
memory and select one among USB: PENDANT, USB1:
CONTROLLER and USB2: CONTROLLER in the {DEVICE}.
3. Select {FD/PC CARD} under the main menu.
The sub menu appears.
9-3
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.2 Backup by CMOS.BIN
4. Select {SAVE}.
The save display appears.
9-4
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.2 Backup by CMOS.BIN
6. Select {YES}.
Select {YES} to save the CMOS data into the CompactFlash.
When saving the file, if the CMOS.BIN file already exists in the
CompactFlash, the following confirmation dialog box appears.
7. Select {YES}.
The CMOS.BIN file is overwritten in the CompactFlash.
9.2.2
CMOS.BIN Load
Follow the procedures below to load CMOS.BIN.
1. Turn ON the DX200 power supply while pressing [MAIN MENU].
2. Change the security mode to the maintenance mode or higher mode.
3. Insert a CompactFlash into the CompactFlash on the programming
pendant.
When USB memory is used instead of CompactFlash, mount USB
memory and select one among USB: PENDANT, USB1:
CONTROLLER and USB2: CONTROLLER in the {DEVICE}.
4. Select {FD/PC CARD} under the main menu.
The sub menu appears.
9-5
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.2 Backup by CMOS.BIN
5. Select {LOAD}.
The load display appears.
7. Select {YES}.
The loaded CMOS.BIN file contents are reflected in the data inside
the robot.
CAUTION
When the CMOS load is performed, the current CMOS data is
replaced with the CMOS data (the contents of "CMOS.BIN") in the
CompactFlash. Therefore, before performing the load, make sure to
perform the CMOS Save of the CMOS data to be loaded.
9-6
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
9.3
9.3.1
9.3.1.1
Objective
With the automatic backup function, the data saved in the DX200 such as
system setting or operational condition are collectively backed up in the
CompactFlash, which is stored in the programming pendant, or the
selected device at the automatic backup window.
speed ethernet server function is effective.)
DN1.50-00 or higher: The automatic backup function is expanded. In
order to use the automatic backup extension function, set the following
parameter.
For the setting of the automatic backup extension function, refer to section
9.3.2.7 AUTO BACKUP EXTENSION FUNCTION SET Window .
Parameter
Content
Initial Value
S2C737
NOTE
9.3.1.2
Outline
The automatic backup function saves the internally stored data in a single
file in advance for the smooth restoration from unexpected troubles of the
DX200.
The teaching operation is one of the factors that changes the internally
stored data. Thus, a mode which backs up the latest data after the
teaching operation is prepared. To confirm the termination of the teaching
operation, check the mode key whether it is changed from teach mode to
play mode.
Other than the teaching operation, the present position of the robot or the
value of a variable can be pointed out as the factors to change the
internally stored data. These data, however, are changed after each
operation and have very little need to be retained permanently.
Accordingly, backing up these data at regular interval should be well
enough to operate and the mode to back up the data at regular interval is
also prepared.
Furthermore, the mode to back up the data when starting up the DX200
and when inputting signals are also available for some specific versions.
9-7
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
With the automatic backup function, all the part where the internal data is
stored in the physical memory area is collectively saved. If there is any
data which is in the middle of changing while executing the automatic
backup function, the data might not be usable for restoration because of
its inconsistency. Therefore, the function is terminated with an error
during the play back operation or while the manipulator is in motion so that
the automatic backup cannot be operated. Set the automatic backup
function to be executed while the manipulator is not in the playback status
and while the manipulator is stopped.
The automatic backup function has the following functions and features.
No Function/Feature
Explanation
Cyclic backup
In the teach mode, the data in
memory is backed up in a specified
cycle from a specified starting time.
Backup in binary
The data is saved as binary data.
Setting of items
Parameters can limit the settings of
the backup condition.
9-8
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
9.3.2
NOTE
9.3.2.1
9-9
RE-CTO-A220
165292-1CD
DX200 Controller
9.3.2.2
9 System Backup
9.3 Automatic Backup Function
NOTE
9-10
RE-CTO-A220
165292-1CD
DX200 Controller
9.3.2.3
9 System Backup
9.3 Automatic Backup Function
9.3.2.4
From a
specified
starting time
When a
specified signal
(#40560) is
input
Teach mode
Automatic Backup
Editing
(Accessing to
the memory)
Compact
Flash
ready to
save the
data
Absence or
insufficient
capacity of the
CompactFlash
Retry
Retry
Error
Play mode
Remote mode
Executing jobs
Disabled
Disabled
When stopped
Backup
Error
Teach mode
Editing
(Accessing to
the memory)
Error
Error
Error
Executing jobs
Disabled
Disabled
When stopped
Backup
Error
Backup
Error
When the
DX200 starts
up
Backup
Error
Play mode
Remote mode
9-11
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
9-12
RE-CTO-A220
165292-1CD
DX200 Controller
9.3.2.5
9 System Backup
9.3 Automatic Backup Function
Setting Examples
Setting Example 1
The following diagram shows a setting example with the following
conditions:
BASE TIME: 12:30
BACKUP CYCLE: 60 (minutes)
RETRY CYCLE: 10 (minutes)
BASE TIME
Power ON
BACKUP CYCLE
RETRY CYCLE
11:00
1st day
11:30 11:40
1st day
11:50
12:30
1st day
Backup
Backup
13:30
1st day
Backup
Setting Example 2
The following diagram shows a setting example with the following
conditions:
BASE TIME: 20:00
BACKUP CYCLE: 1440 (minutes) (24 hours)
RETRY CYCLE: 60 (minutes)
Power ON
BASE TIME
BACKUP CYCLE
RETRY CYCLE
8:00
1st day
20:00 21:00
1st day
22:00
20:00
2nd day
Backup
NOTE
Backup
20:00
3rd day
Backup
9-13
RE-CTO-A220
165292-1CD
DX200 Controller
9.3.2.6
9 System Backup
9.3 Automatic Backup Function
Settings
Select the following items on the AUTO BACKUP SET display and set
values for the automatic backup.
RESERVE TIME BACKUP (VALID/INVALID of the cyclic backup)
BASE TIME
BACKUP CYCLE
RETRY CYCLE
MODE CHANGE BACKUP (VALID/INVALID of the backup when
switching the mode from teach mode to play mode)
STARTUP AUTO BACKUP (VALID/INVALID of the backup when the
DX200 is started up)
SPECIFIC INPUT BACKUP (VALID/INVALID of the backup when
inputting specified signals)
UNIV.OUT NO. ON ERROR
DISPLAY AT EMERGENCY
DURING ALARM OCCURENCE
STORED FILE SETTING (It is possible to set when CF:pendant is
set on the device.)
When the CF: pendant or CF:Controller is selected on
the auto backup display, the capacity of the CompactFlash
card in the specified device will be checked. Therefore, a
few seconds may be needed to open the setting window.
For the CF: Pendant, an error may occur without seting in
the CompactFlash card.
NOTE
9-14
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
1. Turn ON the DX200.
Insert the CompactFlash to the programming pendant, when the
backup is set on the CompactFlash of the programming pendant.
2. Change the security mode to the management or higher mode.
3. Select {SETUP} under the main menu.
4. Select {AUTO BACKUP SET}.
The AUTO BACKUP SET display appears.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
9-15
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
D. RETRY CYCLE
Specify the length of time for a cycle to retry backing up when the
backup operation is suspended.
After being suspended, the backup is retried in the time specified in the
RETRY CYCLE.
Set the retry cycle in units of minutes. The cycle setting ranges from 0
to 255, and is shorter than the BACKUP CYCLE.
When it is set to 0, retry will not be performed.
E. MODE CHANGE BACKUP
Set the automatic backup function to be valid or invalid when the mode
is switched from teach mode to play mode.
Each time [SELECT] is pressed, "INVALID" and "VALID" are displayed
alternately.
F. STARTUP AUTO BACKUP
Set the backup function to be valid or invalid when the power of the
DX200 is turned ON.
Each time [SELECT] is pressed, "INVALID" and "VALID" are displayed
alternately.
G. SPECIFIC INPUT BACKUP
Set the backup function to be valid or invalid when specific input signal
(# 40560) is input (rising edge from 0 to 1).
Each time [SELECT] is pressed, "INVALID" and "VALID" are displayed
alternately.
H. UNIV.OUT NO. ON ERROR
Set "1" to the specified user output signal which was specified in this
chapter when the automatic backup error occurs.
The term "automatic backup error" here means that the backup is not
performed successfully before the next backup (including retry operation) starts.
I. DISPLAY AT EMERGENCY
Set the method of notification of the automatic backup error to
"ERROR" or "MESSAGE."
Each time [SELECT] is pressed, "ERROR" and "MESSAGE" are displayed alternately.
J. DURING ALARM OCCURENCE
Set the backup function to be valid or invalid when an alarm occurs.
Each time [SELECT] is pressed, "INVALID" and "VALID" are displayed
alternately.
9-16
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
K.DEVICE
Press {SELECT} to display the device list.
The Device Name in Display
Explanation
CF: pendant
CF: controller
RAMDISK
USB1: controller
USB2: controller
9-17
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
Window Settings
RS parameter can restrict the settings of some items in the automatic
backup window.
When setting the bit of RS096 parameter shown below to "1", the
corresponding items are restricted. The restricted items are indicated with
"INVALID" in the display and inputting/modification to the item becomes
impossible. Also, the automatic backup does not function with the
restricted items.
D7 D6 D5 D4 D3 D2 D1 D0
9-18
RE-CTO-A220
165292-1CD
DX200 Controller
9.3.2.7
9 System Backup
9.3 Automatic Backup Function
Settings
Automatic backup setting is performed by setting the following items on
the AUTO BACKUP SET window:
RESERVE TIME BACKUP
(Setting for performing the backup on what day of the week, every
day, or in a specific cycle)
BASE TIME
BACKUP CYCLE
RETRY CYCLE
MODE CHANGE BACKUP
(VALID/INVALID of the backup when switching the mode from the
teach mode to the play mode)
STARTUP AUTO BACKUP
(VALID/INVALID of the backup when the DX200 is started up)
SPECIFIC INPUT BACKUP
(VALID/INVALID of the backup when inputting specified signals)
UNIV.OUT NO. ON ERROR
DISPLAY AT EMERGENCY
DURING ALARM OCCURENCE
DEVICE
(Setting of the device to store the automatic backup file)
STORED FILE SETTING
(It is possible to set when CF:Pendant is set in DEVICE.)
NOTE
9-19
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
1.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
9-20
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
"INVALID"
"SET CYCLE"
B. BASE TIME
Specify the reference time to start the automatic backup.
The reference time ranges from 0:00 to 23:59.
C. BACKUP CYCLE
Specify the backup cycle to perform the cyclic back up.
Set the backup cycle in units of minutes. The cycle setting ranges from
10 to 9999 minutes. After the first backup, the following backups are
performed automatically in every BACKUP CYCLE.
When "EVERY DAY" or the day of the week ("MONDAY" to "SUNDAY")
for RESERVE TIME BACKUP is selected, BACKUP CYCLE cannot be
input.
9-21
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
D. RETRY CYCLE
Every time the automatic backup is implemented, the memory data in
the controller is obtained, and the data is compared with the original
memory data. If they are not the same, the retry of the automatic
backup is implemented. However, please note that when the device is
not inserted and the automatic backup is failed, for example, the retry is
not executed.
Set the retry cycle in units of minutes. The cycle setting ranges from 0
to 255, and should be shorter than the BACKUP CYCLE. If the value is
the same as or longer than the BACKUP CYCLE, RESERVE TIME
BACKUP cannot set to "VALID".
When it is set to 0, retry will not be performed.
E. MODE CHANGE BACKUP
Set the automatic backup function to be valid or invalid when the mode
is switched from teach mode to play mode.
Each time [SELECT] is pressed, "INVALID" and "VALID" are displayed
alternately.
F. STARTUP AUTO BACKUP
Set the backup function to be valid or invalid when the power of the
DX200 is turned ON.
Each time [SELECT] is pressed, "INVALID" and "VALID" are displayed
alternately.
G. SPECIFIC INPUT BACKUP
Set the backup function to be valid or invalid when specific input signal
(# 40560) is input (rising edge from 0 to 1).
Each time [SELECT] is pressed, "INVALID" and "VALID" are displayed
alternately.
H. UNIV.OUT NO. ON ERROR
Set "1" to the specified user output signal which was specified in this
chapter when the automatic backup error occurs.
The term "automatic backup error" here means that the backup is not
performed successfully before the next backup (including retry operation) starts.
I. DISPLAY AT EMERGENCY
Set the method of notification of the automatic backup error to
"ERROR" or "MESSAGE."
Each time [SELECT] is pressed, "ERROR" and "MESSAGE" are displayed alternately.
J. DURING ALARM OCCURENCE
Set the backup function to be valid or invalid when an alarm occurs.
Each time [SELECT] is pressed, "INVALID" and "VALID" are displayed
alternately.
9-22
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
K.DEVICE
Press {SELECT} to display the device list.
The Device Name in Display
Explanation
CF: pendant
CF: controller
RAMDISK
USB1: controller
USB2: controller
9-23
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
Window Settings
RS parameter can restrict the settings of some items in the automatic
backup window.
When setting the bit of RS096 parameter shown below to "1", the
corresponding items are restricted. The restricted items are indicated with
"INVALID" in the display and inputting/modification to the item becomes
impossible. Also, the automatic backup does not function with the
restricted items.
D7 D6 D5 D4 D3 D2 D1 D0
NOTE
9-24
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.3 Automatic Backup Function
9.3.3
9.3.3.1
Parameter number
Contents
Setting value
S0C682
0 (Invalid)
1 (Valid)
NOTE
9-25
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.4 Loading the Backup Data from the CompactFlash
9.4
9.4.1
Loading Procedure
To restore from the CompactFlash of the programming pendant, perform
the following procedures No.1 to 8. To restore from the CompactFlash on
the YCP21 board, perform the following procedures from No.9.
For the USB memory, select one among the USB: pendant, USB1:
controller and USB2: controller in the {EX. MEMORY} -{DEVICE} to
restore.
1. Insert the CompactFlash with the backup data in the CompactFlash
slot on the programming pendant.
(When selecting USB1: controller or USB2: controller, insert it in the
YCP21 board.)
The backup data is stored under the file name "CMOSBK.BIN" or
"CMOSBK??.BIN" (?? denotes figures.)
2. Turn ON the DX200 power supply while pressing [MAIN MENU].
3. Change the security mode to the management or higher mode.
4. Select {EX. MEMORY} under the main menu.
The sub menu appears.
9-26
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.4 Loading the Backup Data from the CompactFlash
When set the {SYSTEM}- {SETUP}- {OPTIONAL FUNCTION}{AUTO BACKUP (YCP21)} as USE, the following sub menu
appears.
9-27
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.4 Loading the Backup Data from the CompactFlash
6. Select the file to be loaded.
The dialog box appears for the YIF/YCP21 board replacement
confirmation.
9-28
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.4 Loading the Backup Data from the CompactFlash
9. Turn the power on, while pressing the [MAIN MENU].
10. Change the security mode to the management or higher mode.
11. Select {External memory} in the main menu.
The sub menu will appear. .
9-29
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.4 Loading the Backup Data from the CompactFlash
13. Select desired date file.
The YIF/YCP21 board dialog will appear.
9-30
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.4 Loading the Backup Data from the CompactFlash
CAUTION
Note that executing "SYSTEM RESTORE" or SYSTEM RESTORE
(YCP21) replaces the current CMOS data with the data of the file
"CMOSBK.BIN" or "CMOSBK??.BIN" (?? denotes figures) in the
CompactFlash.
After "CMOSBK.BIN" has been loaded, check if the new data is the
same as the previously saved data in the CMOS, and call the master
job to confirm that the current manipulator position is correct and safe.
Then, start moving the manipulator.
9-31
RE-CTO-A220
165292-1CD
DX200 Controller
9 System Backup
9.5 Error List
9.5
9.5.1
Error List
Error Contents
Cause
No.
0770
3390
3430
3460
3501
3550
3551
3560
3580
3581
9-32
RE-CTO-A220
165292-1CD
DX200 Controller
10 Upgrade Function
10.1 Functional Overview
10 Upgrade Function
10.1
Functional Overview
DX200 applies two software for the CPU configuration: a software for
YCP21 (for the main CPU board) and a software for YPP (for
programming pendant). The system works only with the combination of
certain versions due to a compatibility problem of each software.
Therefore, with the system version NS3.00 and the subsequent versions,
DX200 can upgrade the software for YPP if the combination of the
software for YCP21 and YPP is invalid.
10.2
Upgrade Procedure
10-1
RE-CTO-A220
165292-1CD
DX200 Controller
10 Upgrade Function
10.2 Upgrade Procedure
10.2.2
NOTE
NOTE
10-2
RE-CTO-A220
165292-1CD
DX200 Controller
10 Upgrade Function
10.2 Upgrade Procedure
NOTE
10-3
RE-CTO-A220
165292-1CD
DX200 Controller
10 Upgrade Function
10.3 Error Message
10.3
Error Message
If Error occurs while automatic upgrading, exercise the following
procedure.
10-4
RE-CTO-A220
165292-1CD
DX200 Controller
11 Programming Pendant
11.1 Disconnection Function
11 Programming Pendant
11.1
Disconnection Function
Disconnection function enables to cut off the communication between the
programming pendant and the controller.
1. Long press [Simple Menu] key to show the pop-up menu.
11-1
RE-CTO-A220
165292-1CD
DX200 Controller
11 Programming Pendant
11.1 Disconnection Function
3. Select YES to disconnect the communication between the controller
and the programming pendant. After disconnecting the
communication, the message is displayed.
11-2
RE-CTO-A220
165292-1CD
DX200 Controller
11 Programming Pendant
11.2 Reset Function
11.2
Reset Function
Reset function enables to restart only the programming pendant while the
main power supply of the controller is ON.
If unable to operate the robot by the programming pendant causing from
the communications error of the programming pendant, recover the
programming pendant by following procedures.
5. Confirmation of the LED (DS1) display on the JANCD-YIF01- E
Check the LED display on the JANCD-YIF01- E.
11-3
RE-CTO-A220
165292-1CD
DX200 Controller
11 Programming Pendant
11.3 Touch Panel Invalidate Function
11.3
2. Move the focus area over the YES on the confirmation dialog by
using [] key.
3. Press [Select] key. The touch panel becomes invalid.
When the touch panel is invalid, an icon, which shows the invalidating
the touch panel, is displayed on the status area, and the message
Touch operation is invalid is displayed on the message area.
11-4
RE-CTO-A220
165292-1CD
DX200 Controller
11 Programming Pendant
11.3 Touch Panel Invalidate Function
2. Move the focus area over the YES on the confirmation dialog by
using [] key.
3. Press [Select].
The touch panel become valid.
NOTE
11-5
RE-CTO-A220
165292-1CD
DX200 Controller
SUPPLEMENT
4. Select {SETUP}.
The SETUP window appears.
The items marked with "" cannot be selected.
12-1
RE-CTO-A220
165292-1CD
DX200 Controller
DO
AI
AO
BOARD
7. Press [ENTER].
Confirm the statuses of the mounted I/O modules for the other
stations.
12-2
RE-CTO-A220
165292-1CD
DX200 Controller
9. Select {YES}.
The system parameters are then set automatically according to the
current mounted hardware status, and the window will be changed
to the external I/O setup window.
NOTE
12-3
RE-CTO-A220
165292-1CD
DX200 Controller
12.2
NOTE
12-4
RE-CTO-A220
165292-1CD
DX200 Controller
12-5
RE-CTO-A220
165292-1CD
DX200 Controller
6. Select MODIFY, and input the external input signal number (at the
change destination) to be changed. (In the setting example, enter
20190.)
The external I/O signal is changed.
12-6
RE-CTO-A220
165292-1CD
DX200 Controller
9. Like the case of the external input signal, select/modify the external
output signal.
Repeat select/modify until it becomes the desired allocation.
10. Press [ENTER].
The confirmation dialog box appears.
12-7
RE-CTO-A220
165292-1CD
DX200 Controller
12-8
RE-CTO-A220
165292-1CD
DX200 Controller
14
16
16
YSF21
#20060
#20070
0
0
254
1
0
1
1
5
DN4-PCU-1
DN4-PCU-1
#20120
16
DN4-PCU-1
#20160
#20190
16
17
0
0
3
254
10
0
3
1
DN4-PCU-1
CCS-PCU
#20200
17
CCS-PCU
17
CH
Indicates the channel number (network communication system) on the
board. The following contents are displayed.
0: I/O area for channel 1
1: I/O area for channel 2
12-9
RE-CTO-A220
165292-1CD
DX200 Controller
12-10
RE-CTO-A220
165292-1CD
DX200 Controller
12.3
SUPPLEMENT
When adding a base and a station axis, set the following items:
TYPE
Select one in the type list.
In case of base axis (B1,B2,B3...B8)
Select one of RECT-X, -Y, -Z, -XY, -XZ, -YZ or -XYZ.
In case of station axis (S1,S2,S3,S4,S5... S24)
Select UNIV-* ("*" represents the number of axes) when using a
mechanism other than the registered type as a station axis.
CONNECTION
In the CONNECTION window, specify the SERVOPACK which is
connected with each axis group, the contactor which is used for the
SERVOPACK, and the overrun signal (OT).
AXIS TYPE
Select from the axis type list.
In case of TURN-* type
No need to select (The axis type is set as TURN type.)
In case of RECT-* type
Select BALL-SCREW type or RACK & PINION type.
In case of UNIV-* type
Select BALL-SCREW type, RACK & PINION type or TURN type.
MECHANICAL SPECIFICATION
If axis type is ball-screw type, set the following items:
MOTION RANGE (+)
[mm]
[mm]
[mm/r]
If axis type is rack & pinion type, set the following items.
MOTION RANGE (+)
[mm]
[mm]
[mm]
12-11
RE-CTO-A220
165292-1CD
DX200 Controller
[deg]
[deg]
[mm]
MOTOR SPECIFICATION
Set the following items.
MOTOR
SERVO AMP
CONVERTER
ROTATION DIRECTION
[normal/reverse]
MAX. RPM
[rpm]
12-12
RE-CTO-A220
165292-1CD
DX200 Controller
12.3.1.1
4. Select {SETUP}.
The SETUP window appears.
Note that the items marked with "" cannot be set.
12-13
RE-CTO-A220
165292-1CD
DX200 Controller
6. Move the cursor to the type of control group to be modified, and press
[SELECT].
The MACHINE LIST window is displayed.
RECT-X: traverse X-axis base
RECT-Y: traverse Y-axis base
RECT-Z: traverse Z-axis base
RECT-XZ: traverse XZ-axis base
RECT-XY: traverse XY-axis base
RECT-XYZ: traverse XYZ-axis base
(See the figures on the next page)
12-14
RE-CTO-A220
165292-1CD
DX200 Controller
RECT-Y
RECT-X
RECT-Z
Y
X
Y
X
CARTESIAN
Y-AXIS
CARTESIAN
X-AXIS
Base axis direction of travel coincides
with robot coordinate X-Axis.
RECT-XY
RECT-YZ
Y
X
CARTESIAN
Y-AXIS
CARTESIAN
Z-AXIS
CARTESIAN CARTESIAN
X-AXIS
Y-AXIS
Base 1st and 2nd axes directions of
travel coincide with robot coordinate
X-Axis and Y-Axis, respecitively.
RECT-XZ
Z
CARTESIAN
Z-AXIS
RECT-XYZ
CARTESIAN
X-AXIS
CARTESIAN
Z-AXIS
Base 1st and 2nd axes directions of
travel coincide with robot coordinate
X-Axis and Z-Axis,respectively.
CARTESIAN
Z-AXIS
Y
X
CARTESIAN CARTESIAN
Y-AXIS
X-AXIS
12-15
RE-CTO-A220
165292-1CD
DX200 Controller
12-16
RE-CTO-A220
165292-1CD
DX200 Controller
12-17
RE-CTO-A220
165292-1CD
DX200 Controller
1st axis
Connector (7CN),
Connector (8CN)
Connector (9CN)
(OT2)
12-18
RE-CTO-A220
165292-1CD
DX200 Controller
12-19
RE-CTO-A220
165292-1CD
DX200 Controller
12-20
RE-CTO-A220
165292-1CD
DX200 Controller
12.3.1.4
Selected group,
type, axis no.,
and axis type
are shown.
MOTION RANGE
Selected group,
type, axis no.,
and axis type
are shown.
MOTION RANGE
12-21
RE-CTO-A220
165292-1CD
DX200 Controller
12-22
RE-CTO-A220
165292-1CD
DX200 Controller
12.3.1.5
Normal direction
12-23
RE-CTO-A220
165292-1CD
DX200 Controller
12-24
RE-CTO-A220
165292-1CD
DX200 Controller
12.3.2.1
12-25
RE-CTO-A220
165292-1CD
DX200 Controller
TURN-1
12-26
RE-CTO-A220
165292-1CD
DX200 Controller
12.3.2.2
Connection Setting
In the CONNECT window, it is specified that each axis of each control
group is connected to which connector of the SERVO board, which break
of the contactor unit, which converter, and which overrun signal.
12-27
RE-CTO-A220
165292-1CD
DX200 Controller
Connector (7CN),
Connector (8CN),
(OT2)
12-28
RE-CTO-A220
165292-1CD
DX200 Controller
12-29
RE-CTO-A220
165292-1CD
DX200 Controller
12-30
RE-CTO-A220
165292-1CD
DX200 Controller
12-31
RE-CTO-A220
165292-1CD
DX200 Controller
OFFSET is displayed on
the screen of the 1st axis
only when the TURN-2 type
is selected.
MOTION RANGE
TURN-2
OFFSET
STATION 1ST AXIS
(INCLINATION AXIS)
12-32
RE-CTO-A220
165292-1CD
DX200 Controller
MOTION RANGE
MOTION RANGE
12-33
RE-CTO-A220
165292-1CD
DX200 Controller
12-34
RE-CTO-A220
165292-1CD
DX200 Controller
12.3.2.5
Normal direction
12-35
RE-CTO-A220
165292-1CD
DX200 Controller
CAUTION
When the data, motion range for example, should be changed after
the addition of a base axis or station axis, the change can be done
in the same procedure as shown above.
In this case, the control axis configuration is not changed so the job
file data should not be initialized.
12-36
RE-CTO-A220
165292-1CD
DX200 Controller
13
DX200 Specification
13 DX200 Specification
WARNING
Make sure that there is no one within the P-point maximum envelope of
the manipulator and that you are in a safe place before turning ON the
DX200 power.
Injury may result from collision with the manipulator to anyone entering
the P-point maximum envelope of the manipulator.
13-1
RE-CTO-A220
165292-1CD
DX200 Controller
13
DX200 Specification
CAUTION
Make sure that a system manager stores the key of the mode select
switch on the programming pendant.
After operation, the key should be removed and stored by the
system manager.
13-2
RE-CTO-A220
165292-1CD
DX200 Controller
13 DX200 Specification
13.1 Specification List
13.1
Specification List
Controller Dust/Splash-proof
Construction
Dimensions
Cooling System
Indirect cooling
Power Supply
3-phase,
200V/220V AC (+10% to -15%) at
60Hz(2%)
200V AC (+10% to -15%) at 50Hz(2%)
Grounding
Noise Level
Less than 62 dB
Digital I/O
Positioning System
By serial communication
(absolute encoder)
Drive Unit
Acceleration/
Deceleration
Memory Capacity
Ambient
Ambient
Conditions
Temperature
Relative Humidity
Vibration
Acceleration
0.5G or less
Others
Type
Dimension
Small capacity
13-3
RE-CTO-A220
165292-1CD
DX200 Controller
13 DX200 Specification
13.2 Function List
13.2
Function List
Programming Coordinate
System
Pendant
Modification of
Operation
Teaching Points
Inching Operation
Possible
Path
Confirmation
Safety
Feature
Maintenance
Function
Interface
Application
Essential
Measures
Running Speed
Limit
User definable
Enable Switch
Collision proof
Frames
Self-Diagnosis
User Alarm
Display
Machine Lock
Door Interlock
Operation Time
Display
Alarm Display
I/O Diagnosis
T.C.P. Calibration
13-4
RE-CTO-A220
165292-1CD
DX200 Controller
13 DX200 Specification
13.3 Programming Pendant
Programing
Functions
Programming
Interactive programming
Language
Robot Motion
Control
Speed Setting
Program Control
Instructions
13.3
Operation
Instructions
Variable
Variable Type
Byte type, Integer-type, Double precisiontype, Real type, Position type, String type
I/O Instructions
Programming Pendant
Material
Dimensions
Displayed Units
Operated Units
Others
13-5
RE-CTO-A220
165292-1CD
DX200 Controller
13 DX200 Specification
13.4 Equipment Configuration
13.4
Equipment Configuration
.
NOTE
Small Capacity
Fig. 13-1: Configuration for Small-Capacity
Machine safety
CPU circuit board
JANCD-YSF21-E
Robot I/F
circuit board
Universal I/O
circuit board
JANCD-YIO21-E
CPU unit
JZNC-YRK21-1E
Control power
supply unit
JZNC-YPS21-E
Emergency stop
button
HW1B-V404R
A
Breaker
NF32-SVF
Power ON unit
JZRCR-YPU51-1
Capacitor module
SRDA-CUA662AA
Regenerative resistor
SMVK500W6R0J A6103
Inside Controller
Back View
Converter
SRDA-COA30A21B-E
Inside Controller
Front View
Front Door
Inside View
CPU Unit
CPU Circuit Board
Robot I/F Circuit Board
13-6
RE-CTO-A220
165292-1CD
DX200 Controller
13 DX200 Specification
13.4 Equipment Configuration
Robot I/F
Machine safety
circuit board
terminal block circuit board
JANCD-YFC22-E
Universal I/O
circuit board
JANCD-YIO21-E
CPU unit
JZNC-YRK21-1E
Control power
supply unit
JZNC-YPS21-E
Amplifier module
(Refer to the chap14.14)
Emergency stop
button
XW1E-BV404MR
Breaker
NF32-SVF
Power ON unit
JZRCR-YPU51-1
Capacitor module
SRDA-CUA133AA
Regenerative resistor
SMVK500W2R0J A5978
Inside Controller
Back View
Converter
SRDA-COA30A21B-E
Inside Controller
Front View
Heat exchanger
TCSIP-16A4Y-OC
Front Door
Inside View
CPU Unit
CPU Circuit Board
Robot I/F Circuit Board
Control Power Supply Unit
Machine Safety I/O Logic Circuit Board
Machine Safety Terminal Block Circuit Board
Universal I/O Circuit Board
Converter
Capacitor Module
Amplifier Module
Breaker
13-7
RE-CTO-A220
165292-1CD
DX200 Controller
13 DX200 Specification
13.4 Equipment Configuration
13.4.2 Cooling System of the Controller Interior
The backside duct fan draws in air from the air intake and expels it from
the air outlet to cool the SERVOPACK. The fan mounted inside the door
circulates the air to keep temperature even throughout the interior of the
DX200. Make sure the door of the DX200 is closed when its used to keep
this cooling system effective.
Fig. 13-3: .Cooling System for Small Capacity
Circulation HCP
Backside Duct Fan
Air Intake
Air Outlet
Heat exchanger
Backside Duct Fan
Air Intake
Air Intake
Air Outlet
Air Outlet
13-8
RE-CTO-A220
165292-1CD
DX200 Controller
14
WARNING
Injury may result from collision with the manipulator to anyone entering
the P-point maximum envelope of the manipulator. Always press the
emergency stop button immediately if there are problems.
14-1
RE-CTO-A220
165292-1CD
DX200 Controller
14
CAUTION
Perform the following inspection procedures prior to performing
teaching operations. If problems are found, correct them immediately,
and be sure that all other necessary processing has been performed.
Check for problems in manipulator movement.
Check for damage to insulation and sheathing of external wires.
Make sure that a system manager stores the key of the mode select
switch on the programming pendant.
After operation, the key should be removed and stored by the
system manager.
14-2
RE-CTO-A220
165292-1CD
DX200 Controller
14
CAUTION
Connect the switch (contact) that turns the dual signals ON and
OFF simultaneously.
If the timing that turns the two signals ON and OFF is not right, a
disagreement alarm occurs. Refer to the figure below.
DX200
Switch
-24V2
Turn ON/OFF
at the same time
Input signal 1
Input signal 2
024V
CAUTION
Since the power supply for each signal is reversed, it will shortcircuit and may cause breakdown of DX200 Unit if the signals are
connected to the same contact point.
DX200
Switch
3
4
-24V2
Input signal 1
Input signal 2
024V
Short-circuit current
14-3
RE-CTO-A220
165292-1CD
DX200 Controller
14.1
(1FU), (2FU)
Fuse for AC control
power supply
0218010P(10A 250V)
(CN603,CM604,CN605)
AC control power
supply connector
(3FU), (4FU)
Fuse for AC cooling fan
GP25(2.5A 250V)
(CN601)
Main power supply
Input connector
(CN606)
AC cooling fan connector
(CN602)
Main power supply output connector
14-4
RE-CTO-A220
165292-1CD
DX200 Controller
14.2
14.2.1
(CN513)
Brake control signal
(CN515)
Control communication
(CN507)
Converter I/F
(CN516)
Control communication
(CN510)
DC control power supply
(F1)
PG power supply protective fuse
(CN502)
PWM amplifier 2 I/F
(CN508)
Encoder signal
(CN504)
PWM amplifier 4 I/F
(CN519)
Analog monitor I/F
(CN506)
PWM amplifier 6 I/F
(CN501)
PWM amplifier 1 I/F
(CN503)
PWM amplifier 3 I/F
(CN505)
PWM amplifier 5 I/F
14-5
RE-CTO-A220
165292-1CD
DX200 Controller
(CN523)
STO control signal I/F
(CN524)
STO control signal I/F
(CN533)
PWM amplifier 9 I/F
CN531(Lower)
PWM amplifier 7 I/F
CN532(Upper)
PWM amplifier 8 I/F
(CN542) Encorder distribution for
the machine safety system (9th axis)
(CN541) Encorder distribution for
the machine safety system (8th axis)
(CN540) Encorder distribution for
the machine safety system (7th axis)
(CN536)
Encoder I/F (9th axis)
(CN535)
Encoder I/F (8th axis)
(CN534)
Encoder I/F (7th axis)
14-6
RE-CTO-A220
165292-1CD
DX200 Controller
14.3
14.3.1
LED
(CN114)
I/O I/F
(Communication with
the optional I/O)
(CN107)
Compact flash
(CN106)
USB
(CN113)
(CN105)
For Programming pendant
DriveI/F
(Communication with the
major axes control circuit board)
PCI Slot X2
Battery
(CN203)
I/O I/F
(Communication with the
functional safety circuit board)
(CN202)
I/O I/F
(Communication with the
machine safety I/O logic
circuit board: 2ch side)
14-7
RE-CTO-A220
165292-1CD
DX200 Controller
14.3.2.1
NOTE
14-8
RE-CTO-A220
165292-1CD
DX200 Controller
14.4
MonitorAlarm Display
(CN154/CN155)
+24V1/+24V2 Power Supply Output
(CN153)
+24V3 Power Supply Output
(CN151)
AC Power Supply Input
(CN152)
Remote Control
14-9
RE-CTO-A220
165292-1CD
DX200 Controller
Items
Specifications
Input
Output Voltage
DC + 5V
DC +24V (24V1: System, 24V2: I/O, 24V3: break)
Indicator
Control Power
ON/OFF
DISPLAY
Color
Status
SOURCE
Green
POWER ON
Green
+5V
Red
+24V
Red
FAN
Red
OHT
Red
To turn ON the DX200 controller power, turn ON the non-fuse breaker of the controller
so that the control power supply is turned ON. If the controller is not located at the
workplace, the control power supply can be turned ON/OFF by an external device,
etc. after the non-fuse breaker of the controller is turned ON. It is operated by the
external switch connected with CN152 of the Control power supply unit as shown in
the following figure. (CN152-1 and CN152-2 are short-circuited when shipment)
CN152
1
R-IN
2
R-INCOM
See section 14.8 break Control Circuit Board (JANCD-YBK21-3E) on page 14-44
for wiring of CN152 connector.
14-10
RE-CTO-A220
165292-1CD
DX200 Controller
14.5
14.5.1
(F2)
Fuse for protecting
the power supply
2A/250V
(CN213)
Power supply input connector
(S1/S2)
Rotary switch
(CN211)
I/O I/F
(Communication with the
CPU unit: 1ch side)
(CN219)
Machine safety terminal circuit
board I/F connector
(CN212)
I/O I/F
(Communication with the
CPU unit: 2ch side)
(CN214)
Major axes control circuit
board I/F connector
(CN218)
PP I/F connector
(CN217)
Contactor control
output connector
NOTE
(CN215)
OT,SHOCK,LAMP
(CN216)
FANALM,FANCTL
14-11
RE-CTO-A220
165292-1CD
DX200 Controller
14.5.2.1 To connect the tool shock sensor directly to the tool shock sensor signal line
1. Disconnect the minus SHOCK (-) and +24V2 pin terminal from the
DINAMIC connector, the machine safety I/O logic circuit board
(YSF22 -CN215). The pin terminal for the shock sensor is attached
on the right side of the controller.
2. Connect the minus SHOCK (-) and +24V2 pin terminals to the signal
line of the tool shock sensor. Use the following pin terminals for
preparing the end of the signal line.
SHOCK-
TMEDN-630809-MA
TMEDN-630809-FA
(manufactured by NICHIFU Co.,
Ltd.)
+24V2
TMEDN-630809-FA
TMEDN-630809-MA
(manufactured by NICHIFU Co.,
Ltd.)
DX200
Machine safety I/O logic
circuit board
TMEDN-630809-FA (NICHIFU)
+24V2
CN215
A3
SHOCK+
TMEDN-630809-MA (NICHIFU)
TMEDN-630809-FA (NICHIFU)
Shock sensor
(Option)
B3
SHOCK-
SHOCKTMEDN-630809-MA (NICHIFU)
14-12
RE-CTO-A220
165292-1CD
DX200 Controller
14.5.2.2
To connect the tool shock sensor with the cable that is built into the manipulator
1. Disconnect the minus SHOCK (-) and +24V2 pin terminal from the
DINAMIC connector, the machine safety I/O logic circuit board
(YSF22 -CN215). The pin terminal for the shock sensor is attached
on the right side of the controller.
2. Connect the minus SHOCK (-) pin terminal to the plus SHOCK(+) pin
terminal of the manipulator.
NOTE
DX200
Machine safety I/O logic
circuit board
CN215
A3
+24V2
TMEDN-630809-FA (NICHIFU)
Shock sensor
(Option)
TMEDN-630809-FA (NICHIFU)
SHOCK+
B3
SHOCK+
SHOCK-
SHOCKTMEDN-630809-MA (NICHIFU)
Supply cables (PG)
SUPPLEMENT
14-13
RE-CTO-A220
165292-1CD
DX200 Controller
14.6
14-14
RE-CTO-A220
165292-1CD
DX200 Controller
Function
Factory Setting
SAFF1+
SAFF1-
-1
-2
Safety Plug
Short-circuit with a
jumper cable
SAFF2+
SAFF2-
-3
-4
EXESP1+
EXESP1-
-5
-6
EXESP2+
EXESP2-
-7
-8
EXDSW1+
EXDSW1-
-9
-10
EXDSW2+
EXDSW2-
-11
-12
FST1+
FST1-
-13
-14
FST2+
FST2-
-15
-16
SSP+
SSP-
-17
-18
EXHOLD+
EXHOLD-
-19
-20
EXSVON+
EXSVON-
-21
-22
SYSRUN+
SYSRUN-
-23
-24
Applicable
Applicable
Short-circuit with a
jumper cable
Short-circuit with a
jumper cable
Full-speed Test
Open
Used to reset the slow speed limit for the test run
in the teach mode.
If this signal input circuit is short-circuited, the
speed of the test run becomes 100% in the teach
mode. If this signals circuit is open, the status
SSP input signal determines the safety speed:
The first slow speed (16%) or second slow speed
(2%).
Slow Speed Mode Selection
Used to determine the speed of the test run when
the FST (full-speed test) signal input circuit is
open.
Open: Second slow speed (2%)
Short-circuit: First slow speed (16%)
External Hold
Used to connect the temporary stop switch of an
external device.
If the signal is input, the job is stopped.
While the signal is input, starting and axis
operations are disabled.
External Servo ON
Short-circuit with a
jumper cable
Short-circuit with a
jumper cable
Open
Open
14-15
RE-CTO-A220
165292-1CD
DX200 Controller
Connection Dual
Function
Factory Setting
No. (MXT)
input
ONEN11+
ONEN11-
-25
-26
ONEN12+
ONEN12-
-27
-28
ONEN21+
ONEN21-
-29
-30
ONEN22+
ONEN22-
-31
-32
ONEN31+
ONEN31-
-33
-34
ONEN32+
ONEN32-
-35
-36
ONEN41+
ONEN41-
-37
-38
ONEN42+
ONEN42-
-39
-40
OT21+
OT21-
-41
-42
OT22+
OT22-
-43
-44
OT31+
OT31-
-45
-46
OT32+
OT32-
-47
-48
OT41+
OT41-
-49
-50
OT42+
OT42-
-51
-52
PPESP3+
PPESP3-
-53
-54
PPESP4+
PPESP4-
-55
-56
PBESP3+
PBESP3-
-57
-58
PBESP4+
PBESP4-
-59
-60
Short-circuit with a
jumper cable
Applicable
Applicable
Open
Open
14-16
RE-CTO-A220
165292-1CD
DX200 Controller
Connection
Dual
No. (MXT)
input
GSIN11+
GSIN11-
-61
-62
GSIN12+
GSIN12-
-63
-64
GSIN21+
GSIN21-
-65
-66
GSIN22+
GSIN22-
-67
-68
GSOUT11+
GSOUT11-
-69
-70
GSOUT12+
GSOUT12-
-71
-72
GSOUT21+
GSOUT21-
-73
-74
GSOUT22+
GSOUT22-
-75
-76
GSEDM1+
GSEDM1-
-77
-78
GSEDM2+
GSEDM2-
-79
-80
+24V2U3
-81
-82
-92
-93
-83
-84
-94
-95
AXDIN_COM
AXDIN1
AXDIN2
AXDIN3
AXDIN4
AXDIN5
AXDIN6
-85
-86
-87
-88
-89
-90
-91
AIN_COM
AXIN1
AXIN2
-96
-97
-98
AXOUT1
AXOUT2
-99
-100
024V2
Function
Factory
Setting
Open
Applicable
Open
Open
Open
Open
Open
Open
14-17
RE-CTO-A220
165292-1CD
DX200 Controller
2. Applicable Wires
(1) The length of the exposed conductor (L) should be as follows:
L
* The length of the exposed conductor set for the terminal block (L)
WAGO series 250 (with 5.0 mm pitch): 9-10 mm
* Applicable max cable outside diameter: 3.1 mm dia.
(2) In case that the conductor is bent or frayed, make it straight as
illustrated in the figure above.
14-18
RE-CTO-A220
165292-1CD
DX200 Controller
(1) Place the screwdriver on the lever upright as shown in the figure
below and push straight down.
(2) Insert the wire into the connection hole slowly until its leading end
touches the end of the hole.
For thin wires, never insert the wire with force, or the wire
jacket may get caught in.
(3) Pull out the screwdriver to clamp the conductor with a spring.
(4) Check if the wire is connected firmly by pulling the wire softly.
14-19
RE-CTO-A220
165292-1CD
DX200 Controller
CAUTION
SUPPLEMENT
Safety plug
SAFF_1+
SAFF_1-
SAFF_2+
SAFF_2-
Turn ON/OFF
at the same time
14-20
RE-CTO-A220
165292-1CD
DX200 Controller
Safeguarding
DX200
Safeguarding
Safety Plug
Taked Plug
Emergency
Stop
If the servo power is ON when the interlock signal is input, the servo
power turns OFF. The servo power cannot be turned ON while the
interlock signal is input. However, the servo power does not turn OFF
when the door is opened only during the teach mode. In this case, the
servo power can be turned ON while the interlock signal is input.
14-21
RE-CTO-A220
165292-1CD
DX200 Controller
CAUTION
EXESP_1+
EXESP_1-
EXESP_2+
EXESP_2-
Turn ON/OFF
at the same time
14-22
RE-CTO-A220
165292-1CD
DX200 Controller
CAUTION
EXDSW1+
10
EXDSW1-
11
EXDSW2+
12
EXDSW2-
Turned ON/OFF
at the same time
14-23
RE-CTO-A220
165292-1CD
DX200 Controller
Full-speed test
13
FST_1+
14
FST_1-
15
FST_2+
16
FST_2-
Turned ON/OFF
at the same time
14-24
RE-CTO-A220
165292-1CD
DX200 Controller
Operation Speed
When the full-speed test mode is set, operation speed is set depending on
the setting of manual speed as follows.
At the time of setting the full-speed mode, the setting of manual speed
shifts to Inching automatically.
When changing the setting of manual speed, make sure that there is no
person around the manipulator and pay great attention to perform the
operation.
Manual
speed
Inching
20%
Slow
50%
Medium
75%
Fast
NOTE
14-25
RE-CTO-A220
165292-1CD
DX200 Controller
CAUTION
SSP+
18
SSP-
14-26
RE-CTO-A220
165292-1CD
DX200 Controller
External Hold
This signal is used to connect the temporary stop switch of an external
device. If the signal is input, the job is stopped. While the signal is input,
starting and axis operations are disabled.
CAUTION
External Hold
19
EXHOLD+
20
EXHOLD-
14-27
RE-CTO-A220
165292-1CD
DX200 Controller
External servo ON
21
EXSVON+
22
EXSVON-
14-28
RE-CTO-A220
165292-1CD
DX200 Controller
SYSRUN OFF
23
SYSRUN-
24
SYSRUN+
SYSRUN-
Because the pulse signal is outputted from the specific output signal
(#50911) to the external device for each 100ms, it is also able to check
whether the DX200s control circuit board is normal or abnormal.
Refer to section 4.12 Specific Output Signals of DX200 OPTIONS
INSTRUCTIONS FOR CONCURRENT I/O (165294-1CD) for more
details.
14-29
RE-CTO-A220
165292-1CD
DX200 Controller
25
ONEN1_1+
26
ONEN1_1-
27
ONEN1_2+
28
ONEN1_2-
Turn ON/OFF
at the same time
14-30
RE-CTO-A220
165292-1CD
DX200 Controller
CAUTION
41
OT2_1+
42
OT2_1-
43
OT2_2+
44
OT2_2-
Turn ON/OFF
at the same time
14-31
RE-CTO-A220
165292-1CD
DX200 Controller
CN219
41
OT2_1+
42
OT2_1-
Turn ON/OFF
at the same time
43
OT2_2+
44
OT2_2-
45
OT3_1+
46
OT3_1-
47
OT3_2+
48
OT3_2-
Turn ON/OFF
at the same time
49
OT4_1+
50
OT4_1-
51
OT4_2+
52
OT4_2-
Turn ON/OFF
at the same time
14-32
RE-CTO-A220
165292-1CD
DX200 Controller
CAUTION
Do not use the emergency stop button with 24 VAC, 0.5 A or more.
Emergency
stop button
CN219
PBESP3+
57
PBESP3-
58
PBESP4+
59
PBESP4-
60
PPESP3+
53
PPESP3-
54
PPESP4+
55
PPESP4-
56
PBESP3+
PBESP3PBESP4+
PBESP4-
Programming pendant
Emergency
stop button
PPESP3+
PPESP3PPESP4+
PPESP4-
14-33
RE-CTO-A220
165292-1CD
DX200 Controller
61
GSIN1_1+
62
GSIN1_1-
63
GSIN1_2+
64
GSIN1_2-
Turn ON/OFF
at the same time
14.6.13
DX200
Machine safety terminal
block circuit board
(JANCD-YFC22-E)
Monitoring signal
14-34
RE-CTO-A220
165292-1CD
DX200 Controller
NOTE
14-35
RE-CTO-A220
165292-1CD
DX200 Controller
Direct-in (Servo) 1
Direct-in (Servo) 2
Direct-in (Servo) 3
Direct-in (Servo) 4
Direct-in (Servo) 5
Direct-in (Servo) 6
024V2
86
AXDIN1
87
AXDIN2
88
AXDIN3
89
AXDIN4
90
AXDIN5
91
AXDIN6
85
AXDIN_COM
81,82
+24V2
83,84
024V2
86
AXDIN1
87
AXDIN2
88
AXDIN3
89
AXDIN4
90
AXDIN5
91
AXDIN6
85
AXDIN_COM
81,82
+24V2
The
part of wiring is that if there is a slave for the coordinated control side
major axes control circuit board (SRDA-EAXA21A).
14-36
RE-CTO-A220
165292-1CD
DX200 Controller
94,95
024V2
97
AXIN1
98
AXIN2
96
AXIN_COM
92,93
+24V2
14.6.16
Machine safety
terminal block
circuit board
(JANCD-YFC22-E)
CN219
AXOUT1
99
100
+24V2
92,93
14-37
RE-CTO-A220
165292-1CD
DX200 Controller
14.7
(CN303)
For Switching External Power Supply
F1,F2
Power Supply Protective Fuse
3.15A/250V
(CN304)
Power Supply Output
(CN307)
Digital I/O
(CN309)
Digital I/O
(CN306)
Digital I/O
(CN308)
Digital I/O
14-38
RE-CTO-A220
165292-1CD
DX200 Controller
B1
A20
A1
B1
A20
A1
Connector A
CN309 CN308
Connector C
CN307 CN306
Connector B
B20
A1
A20
TIFS553YS
B1
A1
B2
A2
B3
A3
B4
A4
B5
A5
B6
A6
21-187-3201 R
B8
A8
B9
A9
B10
A10
B11
A11
+24VU +24VU
B12
A12
B13
A13
B14
A14
FG
Model: TIFS553YS
14-39
RE-CTO-A220
165292-1CD
DX200 Controller
NOTE
Inductive load
Flyback Diode
Current limiting
resistor
Lamp
024VU
14-40
RE-CTO-A220
165292-1CD
DX200 Controller
Servo ON
External Servo ON
External Start
Operating
External Hold
<Timing Chart>
Manipulator
RUN
STOP
ON
While Servo ON OFF
Servo ON
ON
OFF
External Start
ON
OFF
Operating
ON
OFF
External Hold
ON
OFF
Ext. E-Stop
ON
OFF
14-41
RE-CTO-A220
165292-1CD
DX200 Controller
Fig. 14-31: Example of the Servo ON Sequence Circuit from the External Device
Servo ON PB
Servo ON
confirmation
X2
DX200
Servo ON
command
Servo ON
command
Servo power ON
X3 (30011)
Servo ON
confirmation
Servo power ON
While
Servo ON
Run PB (30011)
Selecting
play mode
(30016)
Alarm/Error
occuring
(30013)
Running
confirmation
X5
DX200
Running
X6 (30010)
Start
(Command)
Ex. Start
Command
Running
Confirmation
Running, etc.
External Start
Input
(20011)
Running Output
(30010), etc.
14-42
RE-CTO-A220
165292-1CD
DX200 Controller
CN303
+24VU
1(EX+24VIN) F1
2(EX024VIN) F2
3.15A
CN303
+24VU
+24V
1(EX+24VIN) F1
0V
2(EX024VIN) F2
3.15A
3.15A
3.15A
(Ready by Customer)
024VU
024VU
+24V
+24V
3(+24V)
3(+24V)
4(024V)
4(024V)
024V
024V
NOTE
Power supply circuit for I/O (+24 VU, 024 VU) has 3.15A
fuses (F1, F2).
Install the external power supply outside the DX200 to
avoid electric noise problems.
If the internal power supply is selected and the external
power supply is connected to CN303-1 to -3 and CN303-2
to -4, do not connect the line of the external power supply
to the +24VU and 0VU terminals. The unit may
malfunction if the external power supply is also connected.
14-43
RE-CTO-A220
165292-1CD
DX200 Controller
14.8
14.8.1
(CN403)
Brake power supply input
(CN402)
Brake interlock
(CN401)
Handbrake release unit I/F
(CN400)
Brake I/F
14-44
RE-CTO-A220
165292-1CD
DX200 Controller
14.9
Converter (SRDA-COA30A21B-E)
The converter (SRDA-COA30A21B-E) exchanges the power supply (3phase: AC200/220V) supplied by the power ON unit for DC power supply
and supplies the power to the amplifier module (PWM amplifiers).
(CN557)
Regenerative resistor
(CN556)
Main circuit power
supply output
(CN554)
Grounding detection input
(CN553)
Converter control signal
(CN559)
Power supply regenerative
unit connection
(CN558)
External axes main
circuit connection
(CN552A)
Control power supply output
for six axes amplifier
(CN552B)
Control power supply output
for external axes amplifier
Charge lamp
Grounding terminal
14-45
RE-CTO-A220
165292-1CD
DX200 Controller
14.10
Small capacity
SRDA-CUA662AA
Large capacity
SRDA-CUA133AA
14-46
RE-CTO-A220
165292-1CD
DX200 Controller
14.11
(CN583)
Main circuit power supply input
(CN582)
Control power supply input
(CN582)
Control power supply input
(CN581)
PWM signal
(CN581)
PWM signal
(CN584)
Motor power output
(CN584)
Motor power output
54&###'
54&###'
54&###'
54&###'
54&###'
54&###'
AMP8
AMP7
AMP9
AMP5
AMP4
AMP6
AMP1
AMP3
AMP2
14-47
RE-CTO-A220
165292-1CD
DX200 Controller
14.12
WAGO Connector
The control power supply unit: CN152 on (JZNC-YPS21-E), and CN303
on the universal I/O circuit board (JANCD-YIO21-E) are equipped with a
connector made by WAGO.
The wiring tool for the WAGO connector is necessary to wire the WAGO
connector.
The tools (total 3, 2 types) are supplied with the DX200.
Use them with the appropriate sizes of connectors.
The wiring procedure is described as follows:
1. Insert part A of the wiring tool into one of the holes designed for the
tool.
Part A
Wire
Specification
Connector to be applied
Max cable outside diameter:
Control power supply unit:
(JANC-YPS21-E) CN152 Stripped lentgh:
Max cable outside diameter:
Universal I/O unit:
(JANCD-YIO21-E) CN303 Stripped lentgh:
4.1mm dia.
8-9mm
3.4mm dia.
7mm
2. Insert or pull out the wire while pushing the wiring tool downward
(Direction of the arrow).
Wiring tool for WAGO connector
Push
14-48
RE-CTO-A220
165292-1CD
DX200 Controller
14.13
14.13.1
Arc Welding
Fig. 14-38: JANCD-YIO21-E (CN308 Connector) I/O Allocation and
Connection Diagram (For Arc Welding)
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
CN308 Connector
Logical Connector
Number Number
Each Point
24VDC
6.9 mA (TYP)
Name
External Start
IN
B1
IN
A1
B1
A1
20012 B2
20013 A2
IN
B2
B2
Alarm/Error Reset
-
IN
A2
B3
A2
B3
20015 A3
20016 B4
20017 A4
024VU
A3
B4
IN
IN
A4
A4
B5
B5
A5
A5
B6
B6
A6
A6
B7
024VU
024VU
Work Prohibited
20023 A6
Work Response
IN
024VU
A7
024VU
OUT
B8
B8
30011 A8
Running
Servo is ON
OUT
A8
30012 B9
OUT
B9
A8
B9
OUT
A9
A9
OUT
B10
B10
A10
A10
B11
B11
A11
A11
OUT
B12
B12
OUT
A12
A12
B13
A13
B13
A13
B14
B14
B14
A14
A14
A14
B15
B15
B15
A15
A15
A15
B16 024VU
A16 024VU
B16
A16
024VU
B17 024VU
A17 024VU
B17
A17
024VU
024VU
B18 +24VU
A18 +24VU
B18
A18
+24VU
B19 +24VU
A19 +24VU
B20 FG
B19
A19
B20
FG
A20
A20
024VU
+24VU
B4
20022 B6
Alarm/Error Occurred
30014 B10 Battery Alarm
-1
A3
IN
IN
30013 A9
-2
IN
IN
Interference1 Entrance
Prohibited
Interference2 Entrance
Prohibited
30010 B8
External
Power Supply
+24 VE
024 VE
IN
20020 B5
20021 A5
B7
A7
CN303 Internal
Power Supply
-3
+24 V
024 V
-4
(24V,1A)
Terminal
Number
Signal
20011 A1
20010 B1
20014 B3
Each Point
24VDC
50mA (max.)
024VU
+24VU
+24VU
+24VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-49
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
CN309 Connector
Logical
Number
Each Point
24VDC
6.9mA (TYP)
Connector
Number
Name
Signal
IN
B1
B1
IN
A1
A1
20026 B2
20027 A2
Weaving Prohibited
IN
B2
B2
Sensing Prohibited
IN
20030 B3
IN
A2
B3
A2
B3
20025 A1
20031 A3
IN02
IN03
IN
IN
A3
B4
A3
20032 B4
20033 A4
IN04
IN
A4
A4
20034 B5
20035 A5
IN05
IN
B5
IN06
A5
B5
A5
20036 B6
20037 A6
IN07
IN
IN
IN08
IN
024VU
A7 024VU
30024 B8 Gas Shortage (Monitor) OUT
30025 A8 Wire Shortage (Monitor) OUT
30026 B9 Wire Sticking (Monitor) OUT
-4
External
Power Supply
+24 VE
024 VE
-1
+24VU
-2
024VU
B6
A6
B6
B7
A7
024VU
024VU
B8
B8
A8
B9
A8
B9
A6
A9
A9
OUT
B10
B10
OUT
A10
A10
OUT
B11
B11
OUT
A11
OUT
A11
B12
OUT
A12
A12
OUT
B13
A13
B13
A13
B14
B14
A14
A14
B15
B15
B15
A15
A15
A15
B16 024VU
A16 024VU
B16
A16
024VU
B17 024VU
B17
A17
024VU
024VU
B18
+24VU
A18 +24VU
A18
+24VU
B19 +24VU
A19 +24VU
B19
+24VU
A19
+24VU
OUT
B14
A14
Internal
Power Supply
+24 V
024 V
(24V,1A)
B4
30027 A9
CN303
-3
Terminal
Number
20024 B1
B7
Each Point
24VDC
50mA (max.)
A17 024VU
B18 +24VU
B20 FG
A20
B12
024VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-50
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
CN306 Connector
Logical
Number
Each Point
24VDC
6.9mA (TYP)
Connector
Number
Name
20040 B1
IN09
20041 A1
20042 B2
20043 A2
20044 B3
IN13
20045 A3
IN14
20046 B4
20047 A4
B1
IN10
IN
A1
A1
IN11
IN
B2
B2
IN12
IN
IN
A2
B3
A2
B3
IN
IN
A3
B4
A3
IN15
IN16
IN
A4
A4
B5
B5
A5
A5
B5
A5
B6
A6
B6
A6
B6
B7
A7
024VU
024VU
024VU
024VU
-4
External
Power Supply
+24 VE
024 VE
-1
+24VU
-2
024VU
B4
A6
30040 B8
B8
B8
30041 A8
OUT10
OUT
30042 B9
OUT11
OUT
A8
B9
A8
B9
30043 A9
OUT12
OUT
A9
A9
OUT
B10
B10
OUT
A10
A10
OUT
B11
B11
OUT
A11
B12
A12
A11
B13
A13
B13
A13
B14
B14
B14
A14
A14
A14
B15
B15
B15
A15
A15
A15
B16 024VU
B16
A16
024VU
A17 024VU
B17
A17
024VU
024VU
B18 +24VU
B18
+24VU
A18 +24VU
A18
+24VU
B19 +24VU
B19
+24VU
A19
+24VU
A12
Internal
Power Supply
+24 V
024 V
(24V,1A)
Terminal
Number
B1
User Input
B12
CN303
-3
Signal
IN
B7
A7
Each Point
24VDC
50mA (max.)
B13
A13
A16 024VU
B17 024VU
A19 +24VU
B20 FG
A20
B12
A12
024VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-51
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
Each Point
24VDC
6.9mA (TYP)
CN307 Connector
Logical Connector
Number Number
-4
024 V
(24V,1A)
IN
B1
B1
20051 A1
IN18
IN
A1
A1
20052 B2
20053 A2
IN19
IN
B2
B2
IN20
IN
20054 B3
IN21
IN
A2
B3
A2
B3
20055 A3
IN22
IN23
IN
IN
A3
20056 B4
20057 A4
B4
A3
B4
IN24
IN
A4
A4
B5
B5
A5
A5
B5
A5
B6
A6
B6
A6
B6
B7
A7
024VU
024VU
024VU
024VU
OUT17-
OUT
B8
B8
A8
OUT17+
OUT
A8
OUT18-
OUT
B9
A8
B9
RLY
30051 B9
A9
RLY
OUT18+
OUT
A9
A9
OUT
B10
B10
OUT
A10
A10
OUT
B11
B11
OUT
OUT
A11
B12
A12
A11
A12
RLY
B13
A13
B13
A13
RLY
B14
B14
+24VU
-2
024VU
OUT
OUT
OUT
OUT
OUT
A14
A14
OUT
B15
B15
A15 OUT24+
OUT
A15
A15
B16
A16
024VU
B17
A17
024VU
024VU
B18
A18
+24VU
B19
A19
+24VU
A16 024VU
B17 024VU
A18 +24VU
B19 +24VU
A19 +24VU
B20 FG
A20
RLY
RLY
B12
A14 OUT23+
30057 B15 OUT24-
A17 024VU
-1
A6
30050 B8
B18 +24VU
External
Power Supply
+24 VE
024 VE
Terminal
Number
IN17
B16 024VU
CN303 Internal
Power Supply
-3
+24 V
Signal
20050 B1
B7
A7
Each Point
24VDC
500mA (max.)
Name
RLY
RLY
024VU
+24VU
+24VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-52
RE-CTO-A220
165292-1CD
DX200 Controller
Number
20010
EXTERNAL START
Functions the same as the [START] button in the programming pendant. Only the
rising edge of the signal is valid. It starts robot operation (playback). This signal is
invalid if external start is prohibited from the playback condition display.
20012
20013
ALARM/ERROR RESET
After an alarm or error has occurred and the cause been corrected, this signal resets
the alarm or error.
20015
20016
20020
20021
20022
20023
20026
WEAVING PROHIBITED
Weaving is prohibited while this signal is ON. Use this signal to check taught steps
and movements without performing the weaving operation.
20027
SENSlNG PROHIBITED
Arc sensing is prohibited while this signal is ON. Use this signal to check taught steps
and movements if an arc sensor is mounted.
1 A master job is a job (program) which can be called by CALL MASTER JOB.Other functions are the same as for
normal jobs. Normally, the parent job, which manages the child jobs called up immediately after the power is
turned ON, is set as the master job.
2 See section 8.6 Interference Area on page 8-59.
14-53
RE-CTO-A220
165292-1CD
DX200 Controller
Number
30010
RUNNING
This signal signifies that the job is running. (Signifies that the job is running, system
status is waiting reserved start, or test run is running.) This signal status is the same
status as [START] in the programming pendant.
30011
SERVO IS ON
This signal signifies that the servo power is turned ON, internal processing such as
current position creation is complete, and the system is able to receive the START
command. This signal turns OFF when the servo power supply turns OFF. It can be
used for DX200 status diagnosis for an external start.
30012
30013
ALARM/ERROR OCCURRED
This signal signifies that an alarm or an error occurred. If a major error occurs, this
signal remains ON until the main power is turned OFF.
30014
BATTERY ALARM
This signal turns ON to notify that the battery requires replacing when the voltage
drops from the battery for backup memory of the encoder. Major problems may result
if memory data is lost because of an expired battery. It is recommended to avoid these
problems by using this signal as a warning signal.
30015 to
30017
30020
IN CUBE 1
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 1).
Use this signal to prevent interference with other manipulators and positioners.
30021
IN CUBE 2
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 2).
Use this signal to prevent interference with other manipulators and positioners.
30022
30023
INTERMEDIATE START OK
This signal turns ON when the manipulator operates. It turns OFF when the currently
executed line is moved with the cursor or when editing operation is carried out after
HOLD is applied during operation. Therefore, this signal can be used as a restart
interlock after a HOLD is applied. However, it also turns ON in the teach mode and
TEACH MODE SELECTED signal must be referred together.
30024
30025
30026
30027
14-54
RE-CTO-A220
165292-1CD
DX200 Controller
Handling
Fig. 14-42: JANCD-YIO21-E (CN308 Connector) I/O Allocation and
Connection Diagram (For Handling)
DX200
Universal I/O circuit board(JANCD-YIO21-E)
+24VU
Each Point
24VDC
6.9mA (TYP)
CN308 Connector
Logical Connector
Number Number
Name
IN
B1
B1
20011 A1
IN
A1
A1
20012 B2
20013 A2
IN
B2
B2
Alarm/Error Reset
IN
20014 B3
IN
A2
B3
A2
B3
20015 A3
IN
IN
A3
20016 B4
20017 A4
B4
A3
B4
B7
A7
IN
A4
A4
IN
B5
A5
B5
A5
IN
IN
IN
Interference1 Entrance
Prohibited
Interference2 Entrance
Prohibited
024VU
024VU
-4
External
Power Supply
+24 VE
024 VE
-1
+24VU
-2
024VU
B6
A6
B6
B7
A7
024VU
024VU
A6
30010 B8
Running
OUT
B8
B8
30011 A8
Servo is ON
OUT
A8
30012 B9
OUT
B9
A8
B9
30013 A9
Alarm/Error Occurred
OUT
A9
A9
OUT
B10
B10
A10
A10
B11
B11
OUT
A11
OUT
A11
B12
OUT
A12
A12
OUT
B13
A13
B13
A13
B14
B14
B14
A14
A14
A14
B15
B15
B15
A15
A15
A15
B16 024VU
A16 024VU
B16
A16
024VU
B17 024VU
A17 024VU
B17
A17
024VU
024VU
B18 +24VU
A18 +24VU
B18
+24VU
A18
+24VU
B19 +24VU
A19 +24VU
B20 FG
B19
+24VU
A19
+24VU
B20
FG
A20
A20
024VU
+24 V
024 V
(24V,1A)
Terminal
Number
External Start
20022 B6
20023 A6
CN303 Internal
Power Supply
-3
Signal
20010 B1
20020 B5
20021 A5
Each Point
24VDC
50mA (max.)
OUT
B12
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-55
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board(JANCD-YIO21-E)
+24VU
Each Point
24VDC
6.9mA (TYP)
CN309 Connector
Logical Connector
Number Number
Name
-4
External
Power Supply
+24 VE
024 VE
+24 V
024 V
(24V,1A)
IN
B1
B1
20025 A1
IN
A1
A1
IN
B2
B2
IN
A2
B3
A2
B3
20026 B2
20027 A2
20030 B3
IN01
IN
20031 A3
IN02
A3
IN03
IN
IN
A3
20032 B4
20033 A4
B4
B4
IN04
IN
A4
A4
20034 B5
20035 A5
IN05
IN06
IN
B5
A5
B5
A5
20036 B6
20037 A6
IN07
IN
IN
IN08
IN
024VU
024VU
+24VU
-2
024VU
B6
A6
B6
B7
A7
024VU
024VU
A6
30024 B8
OUT
B8
B8
30025 A8
OUT
30026 B9
OUT
A8
B9
A8
B9
30027 A9
OUT
A9
A9
OUT
B10
B10
OUT
A10
A10
OUT
B11
B11
OUT
A11
B12
A12
A11
B13
A13
B13
A13
B14
B14
A14
A14
B15
B15
B15
A15
A15
A15
B16 024VU
A16 024VU
B16
A16
024VU
B17 024VU
B17
A17
024VU
024VU
OUT
OUT
OUT
OUT
B14
A14
A17 024VU
B18 +24VU
-1
Terminal
Number
CN303 Internal
Power Supply
-3
Signal
20024 B1
B7
A7
Each Point
24VDC
50mA (max.)
B12
A12
024VU
B18
+24VU
A18 +24VU
A18
+24VU
B19 +24VU
A19 +24VU
B20 FG
B19
A19
+24VU
B20
FG
A20
A20
024VU
+24VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-56
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
CN306 Connector
Logical Connector
Number Number
Each Point
24VDC
6.9mA (TYP)
Name
IN
B1
B1
20041 A1
IN10
IN
A1
A1
20042 B2
20043 A2
IN11
IN
B2
B2
IN12
IN13
IN
A2
B3
A2
B3
IN
20045 A3
IN14
A3
IN15
IN
IN
A3
20046 B4
20047 A4
B4
B4
IN16
IN
A4
A4
B5
A5
B5
B5
A5
B6
A6
B6
A6
B6
B7
A5
024VU
A7
024VU
024VU
30040 B8
30041 A8
OUT09
OUT10
OUT
B8
B8
OUT
A8
30042 B9
30043 A9
OUT11
OUT12
OUT
B9
A8
B9
OUT
A9
A9
OUT
B10
B10
024VU
OUT
A10
A10
OUT
B11
B11
OUT
A11
B12
A11
B12
A12
A12
A12
B13
B13
A13
B13
A13
B14
B14
A14
A14
B15
B15
B15
A15
A15
A15
B16 024VU
B16
A16
024VU
B17
A17
024VU
024VU
B18
+24VU
A18
+24VU
B19
+24VU
A19
+24VU
A13
A16 024VU
B17 024VU
A17 024VU
B18 +24VU
-1
+24VU
-2
024VU
A6
B7
A7
A14
External
Power Supply
+24 VE
024 VE
Terminal
Number
IN09
B14
CN303 Internal
Power Supply
-3
+24 V
024 V
-4
(24V,1A)
Signal
20040 B1
20044 B3
Each Point
24VDC
50mA (max.)
A18 +24VU
B19 +24VU
A19 +24VU
B20 FG
A20
B12
024VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-57
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
Each Point
24VDC
6.9mA (TYP)
CN307 Connector
Logical Connector
Number Number
20050 B1
Name
IN
B1
B1
20051 A1
IN
A1
A1
20052 B2
20053 A2
Sensor Input 3
IN
B2
B2
Sensor Input 4
IN
20054 B3
Sensor Input 5
IN
A2
B3
A2
B3
20055 A3
Sensor Input 6
A3
20056 B4
IN
IN
A3
Sensor Input 7
B4
B4
20057 A4
Sensor Input 8
IN
A4
A4
B5
B5
A5
A5
A5
B6
A6
B7
024VU
A7
024VU
-2
+24VU
024VU
B7
A7
024VU
024VU
A6
OUT
B8
B8
A8
OUT
A8
A8
30051 B9
A9
OUT
B9
B9
OUT
OUT
A10
B11
B11
OUT
A11
B12
A11
A12
A12
RLY
B13
A13
B13
A13
RLY
B14
B14
A14
A14
B15
B15
OUT
OUT
OUT
OUT
OUT
A17 024VU
A18 +24VU
B19 +24VU
A19 +24VU
B20 FG
A20
RLY
A10
B17 024VU
A9
B10
OUT
OUT
A16 024VU
A9
B10
RLY
OUT
B18 +24VU
-1
B6
B16 024VU
External
Power Supply
+24 VE
024 VE
B6
A6
30050 B8
CN303 Internal
Power Supply
-3
+24 V
024 V
-4
(24V,1A)
Terminal
Number
Signal
Sensor Input 1
Sensor Input 2
B5
Each Point
24VDC
500mA (max.)
OUT
OUT
RLY
RLY
B12
A15
A15
B16
A16
024VU
B17
A17
024VU
024VU
B18
+24VU
A18
+24VU
B19
A19
+24VU
RLY
RLY
024VU
+24VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-58
RE-CTO-A220
165292-1CD
DX200 Controller
Number
20010
EXTERNAL START
Functions the same as the [START] button in the programming pendant. Only the
rising edge of the signal is valid. It starts robot operation (playback). This signal is
invalid if external start is prohibited from the playback condition display.
20012
20013
ALARM/ERROR RESET
After an alarm or error has occurred and the cause been corrected, this signal resets
the alarm or error.
20015
20016
20020
20021
20026
20027
20050 to
20057
SENSOR INPUT 1 - 8
Inputs 1 to 8 are monitored with the HSEN handling specific instructions. Sensor
inputs 1 to 8 correspond to HSEN 1 to 8.
1 A master job is a job (program) which can be called by CALL MASTER JOB. Other functions are the same as for
normal jobs. Normally, the parent job, which manages the child jobs called up immediately after the power is
turned ON, is set as the master job.
2 See section 8.6 Interference Area on page 8-59.
14-59
RE-CTO-A220
165292-1CD
DX200 Controller
Number
30010
RUNNING
This signal signifies that the job is running. (Signifies that the job is running, system
status is waiting reserved start, or test run is running.) This signal status is the same
status as [START] in the programming pendant.
30011
SERVO IS ON
This signal signifies that the servo power is turned ON, internal processing such as
current position creation is complete, and the system is able to receive the START
command. This signal turns OFF when the servo power supply turns OFF. It can be
used for DX200 status diagnosis for an external start.
30012
30013
ALARM/ERROR OCCURRED
This signal signifies that an alarm or an error occurred. If a major error occurs, this
signal remains ON until the main power is turned OFF.
30014
BATTERY ALARM
This signal turns ON to notify that the battery requires replacing when the voltage
drops from the battery for backup memory of the encoder. Major problems may result
if memory data is lost because of an expired battery. It is recommended to avoid these
problems by using this signal as a warning signal.
30015 to
30017
30020
IN CUBE 1
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 1).
Use this signal to prevent interference with other manipulators and positioners.
30021
IN CUBE 2
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 2).
Use this signal to prevent interference with other manipulators and positioners.
30022
30023
INTERMEDIATE START OK
This signal turns ON when the manipulator operates. It turns OFF when the currently
executed line is moved with the cursor or when editing operation is carried out after
HOLD is applied during operation. Therefore, this signal can be used as a restart
interlock after a HOLD is applied. However, it also turns ON in the teach mode and
TEACH MODE SELECTED signal must be referred together.
30050 to
30057
14-60
RE-CTO-A220
165292-1CD
DX200 Controller
General Application
Fig. 14-46: JANCD-YIO21-E (CN308 Connector) I/O Allocation and
Connection Diagram (For General Application)
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
CN308 Connector
Logical Connector
Number Number
Each Point
24VDC
6.9mA (TYP)
Name
20010 B1
20011 A1
Signal
B1
B1
IN
A1
A1
IN
B2
B2
Alarm/Error Reset
IN
A2
B3
A2
B3
External Start
IN
20015 A3
IN
IN
A3
20016 B4
20017 A4
B4
A3
B4
IN
A4
A4
Interference1 Entrance
Prohibited
IN
B5
Interference2 Entrance
Prohibited
IN
IN
A5
B5
A5
20020 B5
20021 A5
Work Prohibited
20022 B6
20023 A6
IN
+24VU
-2
024VU
B7
A6
A7
Running
OUT
B8
B8
30011 A8
Servo is ON
OUT
A8
A8
30012 B9
OUT
B9
B9
A9
A9
OUT
B10
B10
A10
A10
B11
B11
A11
B12
A11
A12
A12
B13
A13
B13
A13
B14
B14
A14
A14
B15
B15
024VU
OUT
OUT
OUT
OUT
OUT
B14
A14
B15
-1
B6
30010 B8
024VU
External
Power Supply
+24 VE
024 VE
B6
A6
024VU
024VU
B7
A7
CN303 Internal
Power Supply
-3
+24 V
024 V
-4
(24V,1A)
Terminal
Number
IN
20012 B2
20013 A2
20014 B3
Each Point
24VDC
50mA (max.)
B12
A15
A15
A15
B16 024VU
A16 024VU
B16
A16
024VU
B17 024VU
A17 024VU
B17
A17
024VU
024VU
B18 +24VU
A18 +24VU
B18
+24VU
A18
+24VU
B19
A19
+24VU
B19 +24VU
A19 +24VU
B20 FG
A20
024VU
+24VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-61
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
CN309 Connector
Logical Connector
Number Number
Each Point
24VDC
6.9mA (TYP)
20024 B1
20025 A1
Name
Interference3 Entrance
Prohibited
Interference4 Entrance
Prohibited
-1
+24VU
-2
024VU
B1
B1
IN
A1
A1
IN
B2
B2
IN
20030 B3
IN
A2
B3
A2
B3
20031 A3
IN02
A3
IN03
IN
IN
A3
20032 B4
B4
B4
20033 A4
IN04
IN
A4
A4
20034 B5
20035 A5
IN05
IN
B5
IN06
IN07
IN
IN
A5
B5
A5
IN08
IN
B7
024VU
A7
024VU
B6
A6
B6
B7
A6
A7
024VU
024VU
30024 B8
In Cube 3
OUT
B8
B8
30025 A8
In Cube 4
OUT
A8
A8
30026 B9
30027 A9
Work Instruction
OUT
B9
B9
OUT
A9
A9
OUT
B10
B10
OUT
A10
A10
OUT
B11
B11
OUT
A11
OUT
A11
B12
OUT
A12
A12
OUT
OUT
B13
A13
B13
A13
B14
B14
A14
A14
B15
B15
B15
A15
A15
A15
B16 024VU
A16 024VU
B16
A16
024VU
B17 024VU
B17
A17
024VU
024VU
External
Power Supply
+24 VE
024 VE
Terminal
Number
IN
20037 A6
CN303 Internal
Power Supply
-3
+24 V
024 V
-4
(24V,1A)
Signal
20026 B2
20027 A2
20036 B6
Each Point
24VDC
50mA (max.)
B14
A14
A17 024VU
B18 +24VU
B12
024VU
B18
+24VU
A18 +24VU
A18
+24VU
B19 +24VU
A19 +24VU
B20 FG
B19
+24VU
A19
+24VU
B20
FG
A20
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-62
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
Each Point
24VDC
6.9m A (TYP)
CN306 Connector
Name
Logical Connector
Number Number
Terminal
Number
Signal
IN
B1
B1
IN10
IN
A1
A1
IN11
IN
B2
B2
A2
B3
A2
B3
A3
A3
B4
B4
A4
A4
B5
B5
A5
20040 B1
IN09
20041 A1
20042 B2
20043 A2
General Input
IN12
IN
20044 B3
IN13
IN
20045 A3
IN14
20046 B4
IN15
IN
IN
20047 A4
IN16
IN
B5
A5
A5
B6
B6
A6
B6
B7
A7
024VU
024VU
B8
B8
A8
A8
A6
B7
A7
024VU
30040 B8
OUT09
30041 A8
OUT10
OUT
30042 B9
30043 A9
OUT11
OUT
024VU
General Output
OUT12
OUT
OUT
OUT
OUT
OUT
B12
A12
B13
A13
Each Point
24VDC
50mA (max.)
B14
A14
B15
A15
B16 024VU
CN303 Internal
Power Supply
-3
+24V
024V
-4
(24V, 1A)
A16 024VU
B17 024VU
A17 024VU
B18 +24VU
External
Power Supply
+24VE
024VE
-1
-2
+24VU
024VU
OUT
A18 +24VU
B19 +24VU
A19 +24VU
B20 FG
A20
A6
B9
B9
A9
A9
B10
B10
A10
A10
B11
B11
A11
B12
A11
A12
A12
B13
A13
B13
A13
B14
B14
A14
A14
B15
B15
B12
A15
A15
B16
A16
024VU
B17
A17
024VU
024VU
B18
+24VU
A18
+24VU
B19
+24VU
A19
+24VU
024VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-63
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
Each Point
24VDC
6.9mA (TYP)
CN307 Connector
Logical
Number
Connector
Number
Name
IN17
IN
B1
B1
20051 A1
IN18
IN
A1
A1
20052 B2
20053 A2
IN19
IN
B2
B2
IN20
IN
20054 B3
IN21
IN
A2
B3
A2
B3
20055 A3
IN22
A3
IN23
IN
IN
A3
20056 B4
B4
B4
20057 A4
IN24
IN
A4
A4
B5
B5
A5
A5
A5
B6
B6
A6
B6
B7
A6
A7
30050 B8
OUT17-
OUT
B8
B8
A8
OUT17+
OUT
A8
OUT18-
OUT
A8
B9
RLY
B9
OUT18+
OUT
RLY
30051 B9
A9
024VU
024VU
-1
+24VU
-2
024VU
A9
A9
B10
OUT
B10
OUT
A10
A10
OUT
B11
B11
OUT
OUT
A11
B12
A11
A12
A12
RLY
OUT
B13
A13
B13
A13
RLY
OUT
B14
B14
A14 OUT23+
30057 B15 OUT24-
A14
A14
OUT
B15
B15
A15 OUT24+
OUT
A15
A15
B16
A16
024VU
B17
A17
024VU
024VU
B18
+24VU
A18
+24VU
B19
A19
+24VU
OUT
OUT
OUT
B16 024VU
External
Power Supply
+24 VE
024 VE
A6
024VU
024VU
B7
A7
CN303 Internal
Power Supply
-3
+24 V
-4
024 V
(24V,1A)
Terminal
Number
Signal
20050 B1
B5
Each Point
24VDC
500mA (max.)
A16 024VU
B17 024VU
A17 024VU
B18 +24VU
A18 +24VU
B19 +24VU
A19 +24VU
B20 FG
A20
RLY
RLY
B12
RLY
RLY
024VU
+24VU
B20
FG
A20
024VU
*
RLY
means
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-64
RE-CTO-A220
165292-1CD
DX200 Controller
Number
20010
EXTERNAL START
Functions the same as the [START] button in the programming pendant. Only the
rising edge of the signal is valid. It starts robot operation (playback). This signal is
invalid if external start is prohibited from the playback condition display.
20012
20013
ALARM/ERROR RESET
After an alarm or error has occurred and the cause been corrected, this signal resets
the alarm or error.
20015
20016
20020
20021
20022
20024
20025
1 A master job is a job (program) which can be called by CALL MASTER JOB.
Other functions are the same as for normal jobs. Normally, the parent job, which manages the child jobs called
up immediately after the power is turned ON, is set as the master job.
2 See section 8.6 Interference Area on page 8-59.
14-65
RE-CTO-A220
165292-1CD
DX200 Controller
Number
30010
RUNNING
This signal signifies that the job is running. (Signifies that the job is running, system
status is waiting reserved start, or test run is running.) This signal status is the same
status as [START] in the programming pendant.
30011
SERVO IS ON
This signal signifies that the servo power is turned ON, internal processing such as
current position creation is complete, and the system is able to receive the START
command. This signal turns OFF when the servo power supply turns OFF. It can be
used for DX200 status diagnosis for an external start.
30012
30013
ALARM/ERROR OCCURRED
This signal signifies that an alarm or an error occurred. If a major error occurs, this
signal remains ON until the main power is turned OFF.
30014
BATTERY ALARM
This signal turns ON to notify that the battery requires replacing when the voltage
drops from the battery for backup memory of the encoder. Major problems may result
if memory data is lost because of an expired battery. It is recommended to avoid these
problems by using this signal as a warning signal.
30015 to
30017
30020
IN CUBE 1
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 1).
Use this signal to prevent interference with other manipulators and positioners.
30021
IN CUBE 2
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 2).
Use this signal to prevent interference with other manipulators and positioners.
30022
30023
INTERMEDIATE START OK
This signal turns ON when the manipulator operates. It turns OFF when the currently
executed line is moved with the cursor or when editing operation is carried out after
HOLD is applied during operation. Therefore, this signal can be used as a restart
interlock after a HOLD is applied. However, it also turns ON in the teach mode and
TEACH MODE SELECTED signal must be referred together.
30024
IN CUBE 3
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 3).
Use this signal to prevent interference with other manipulators and positioners.
30025
IN CUBE 4
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 4).
Use this signal to prevent interference with other manipulators and positioners.
30026
WORK COMMAND
This signal provides the command for the general tool to operate. TOOL ON
instruction execution or the [TOOL ON] key in the programming pendant turns this
signal ON and TOOL OFF instruction execution or the [TOOL OFF] key in the
programming pendant turns it OFF. However, it remains OFF while the WORK
PROHIBITED signal (2022) is input or while the robot is stopped.
14-66
RE-CTO-A220
165292-1CD
DX200 Controller
Spot Welding
Fig. 14-50: JANCD-YIO21-E (CN308 Connector) I/O Allocation and
Connection Diagram (For Spot Welding)
DX200
Universal I/O circuit board(JANCD-YIO21-E)
+24VU
CN308 Connector
Logical Connector
Number Number
Each Point
24VDC
6.9mA (TYP)
Name
20010 B1
20011 A1
IN
B1
B1
IN
A1
A1
IN
B2
B2
Alarm/Error Reset
IN
A2
B3
A2
B3
IN
IN
A3
A3
B4
B4
IN
A4
A4
Interference1 Entrance
Prohibited
IN
B5
Interference2 Entrance
Prohibited
IN
IN
B5
A5
External Start
IN
20015 A3
20016 B4
20017 A4
20020 B5
20021 A5
20022 B6
20023 A6
Welding ON/OFF
Welding Pause
IN
-1
-2
+24VU
024VU
B6
A6
B6
B7
A6
A7
OUT
B8
B8
30011 A8
Servo is ON
OUT
A8
A8
30012 B9
30013 A9
OUT
024VU
024VU
30010 B8
Running
B9
B9
A9
A9
OUT
30014 B10 Battery Alarm
30015 A10 Remote Mode Selected OUT
OUT
30016 B11 Play Mode Selected
B10
B10
A10
A10
B11
B11
A11
B12
A12
A11
B13
A13
B13
A13
B14
B14
A14
A14
B15
B15
OUT
30021 A12 In Cube 2
30022 B13 Work Home Position OUT
Intermediate Start OK
30023 A13 (continuousing Sequence) OUT
B14
A14
B15
External
Power Supply
+24 VE
024 VE
A5
024VU
024VU
B7
A7
CN303 Internal
Power Supply
-3
+24 V
024 V
-4
(24V,1A)
Terminal
Number
Signal
20012 B2
20013 A2
20014 B3
Each Point
24VDC
50mA (max.)
B12
A12
A15
A15
A15
B16 024VU
A16 024VU
B16
A16
024VU
B17 024VU
A17 024VU
B17
A17
024VU
024VU
B18 +24VU
A18 +24VU
B18
+24VU
A18
+24VU
B19
+24VU
A19
+24VU
B19 +24VU
A19 +24VU
B20 FG
A20
024VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-67
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
CN309 Connector
Logical Connector
Number Number
Each Point
24VDC
6.9mA (TYP)
Name
IN
B1
B1
20025 A1
IN
A1
A1
20026 B2
20027 A2
IN
B2
B2
IN
20030 B3
IN
A2
B3
A2
B3
20031 A3
IN2
A3
IN3
IN
IN
A3
20032 B4
20033 A4
B4
B4
IN
A4
A4
IN
B5
A5
B5
A5
IN4
IN5
20034 B5
20035 A5
IN6
20036 B6
IN7
IN
IN
IN8
IN
External
Power Supply
+24 VE
024 VE
A7
024VU
In Cube 3
A7
OUT
B8
B8
30025 A8
In Cube 4
OUT
A8
30026 B9
30027 A9
A8
B9
A9
A9
OUT
B10
B10
OUT
A10
A10
OUT
B11
B11
OUT
A11
B12
A12
A11
B13
A13
B13
A13
B14
B14
A14
A14
B15
B15
OUT
OUT
OUT
OUT
OUT
OUT
B14
A14
-2
024VU
B9
B12
A12
A15
A15
A15
B16 024VU
A16 024VU
B16
A16
024VU
B17 024VU
B17
A17
024VU
024VU
B18
+24VU
A18
+24VU
B19
A19
+24VU
A18 +24VU
+24VU
A6
30024 B8
A17 024VU
B18 +24VU
-1
B7
024VU
024VU
B15
+24 V
024 V
(24V,1A)
B6
024VU
-4
B6
A6
B7
CN303 Internal
Power Supply
-3
Terminal
Number
Signal
Interference3 Entrance
Prohibited
Interference4 Entrance
Prohibited
20024 B1
20037 A6
Each Point
24VDC
50mA (max.)
B19 +24VU
A19 +24VU
B20 FG
A20
024VU
+24VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-68
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
CN306 Connector
Logical Connector
Number Number
Each Point
24VDC
6.9mA (TYP)
Name
IN17
IN
B1
B1
20041 A1
IN18
IN
A1
A1
20042 B2
20043 A2
IN19
IN
B2
B2
IN
20044 B3
IN20
IN21
A2
B3
A2
B3
20045 A3
IN22
A3
A3
B4
B4
A4
A4
B5
B5
A5
IN
IN
IN
IN23
IN24
IN
B5
A5
A5
B6
A6
B7
A7
024VU
30040 B8
OUT17
OUT
30041 A8
OUT18
OUT
30042 B9
OUT19
OUT
024VU
30043 A9
OUT
OUT20
30044 B10 OUT21
30045 A10 OUT22
30046 B11 OUT23
OUT
OUT
OUT
OUT
B12
A12
B13
A13
B14
A14
B15
-2
024VU
A7
024VU
024VU
B8
B8
A8
B9
A8
A9
A9
B10
B10
A10
A10
B11
B11
A11
B12
A11
A12
A12
B13
A13
B13
A13
B14
B14
A14
A14
B15
B15
A6
B9
B12
A15
B17
A17
024VU
024VU
B18
+24VU
A18
+24VU
+24VU
B19 +24VU
B19
A19
A19 +24VU
B20 FG
B20
FG
A20
024VU
A16 024VU
B17 024VU
A17 024VU
A18 +24VU
+24VU
B7
024VU
B18 +24VU
-1
B6
B16
A16
B16 024VU
External
Power Supply
+24 VE
024 VE
B6
A6
A15
A15
CN303 Internal
Power Supply
-3
+24 V
024 V
-4
(24V,1A)
Terminal
Number
Signal
20040 B1
20046 B4
20047 A4
Each Point
24VDC
50mA (max.)
A20
024VU
+24VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-69
RE-CTO-A220
165292-1CD
DX200 Controller
DX200
Universal I/O circuit board (JANCD-YIO21-E)
+24VU
Each Point
24VDC
6.9mA (TYP)
CN307 Connector
Logical Connector
Number Number
20050 B1
Name
Timer Cooling Water
Error (IN09)
Gun Cooling Water
Error (IN10)
Signal
B1
B1
IN
A1
A1
20052 B2
20053 A2
B2
B2
IN
20054 B3
IN13
IN
A2
B3
A2
B3
20055 A3
IN14
20056 B4
IN
IN
A3
IN15
B4
A3
B4
20057 A4
IN16
IN
A4
A4
B5
B5
A5
20051 A1
A5
B6
A6
B7
A7
A8
30051 B9
A9
A7
B8
B8
OUT
A8
A8
OUT
B9
B9
A9
OUT
A10
A10
B11
B11
A11
B12
A11
A12
A12
RLY
B13
A13
B13
A13
RLY
B14
B14
A14
A14
B15
B15
OUT
OUT
30055 B13
A15
A15
B16 024VU
B16
A16
024VU
B17
A17
024VU
024VU
B18
+24VU
A18
+24VU
B19
+24VU
A19
+24VU
A16 024VU
B17 024VU
A17 024VU
A18 +24VU
024VU
B19 +24VU
A19 +24VU
B20 FG
A20
RLY
RLY
RLY
B12
B18 +24VU
-2
RLY
B10
OUT
+24VU
A6
A9
30054 B12
-1
B7
B10
30052 B10
External
Power Supply
+24 VE
024 VE
B6
OUT
024VU
Weld ON/OFF (OUT09)***
B6
A6
024VU
024VU
024VU
30050 B8
CN303
Internal
Power Supply
-3
+24 V
024 V
-4
(24V,1A)
Terminal
Number
IN
B5
A5
Each Point
24VDC
500mA (max.)
RLY
RLY
024VU
B20
FG
A20
024VU
024VU
024VU
024VU
024VU
024VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
+24VU
14-70
RE-CTO-A220
165292-1CD
DX200 Controller
Number
20010
EXTERNAL START
Functions the same as the [START] button in the programming pendant. Only the
rising edge of the signal is valid. It starts robot operation (playback). This signal is
invalid if external start is prohibited from the playback condition display.
20012
20013
ALARM/ERROR RESET
After an alarm or error has occurred and the cause been corrected, this signal resets
the alarm or error.
20015
20016
20020
20021
20022
20023
20024
20025
20050
20051
3)
3)
14-71
RE-CTO-A220
165292-1CD
DX200 Controller
Number
20052
TRANSTHERMO ERROR
Error signal is sent from the transformer in the gun to the robot. This signal is ON
normally (NC) and an alarm occurs when the signal is OFF. The servo power supply
remains ON.
20053
4)
WELD COMPLETION
This signal indicates that the Power Source completed welding without error. This
signal is used as a confirmation signal for welding instruction execution and manual
spot welding.
After this signal is input, the welding sequence is completed and the next step is
executed when confirmation limit switch is not provided.
4)
WELDING ERROR
This signal indicates an abnormal welding result or Power Sources error. Alarm
occurs and the manipulator stops if this signal is input during welding.
4)
STICK DETECTION
This signal indicates an abnormal welding result or Power Sources error. Alarm
occurs and the manipulator stops if this signal is input during welding.
4)
4)
4)
4)
3)
3)
1 A master job is a job (program) which can be called by CALL MASTER JOB.
Other functions are the same as for normal jobs. Normally, the parent job, which manages the child jobs called
up immediately after the power is turned ON, is set as the master job.
2 See section 8.6 Interference Area on page 8-59.
3 This signal can be set as USE or NOT USE by pseudo input signal 8202x. If NOT USE is selected, this
signal can be used as the universal I/O signal described in parentheses.
4 This signal can be allocated to any universal I/O signal at the I/O allocation display in operation condition.
Pseudo Input
Signal 8202x
7 6 5 4 3 2 1 0
0 0 0 1 1 1 1 1
Timer Cooling Water Error Validating (or IN09)
Gun Cooling Water Error Validating (or IN10)
Transthermo Error Validating (or IN11)
Low Air Pressure Validating (or IN12)
Weld ON/OFF Validating (or OUT09)
14-72
RE-CTO-A220
165292-1CD
DX200 Controller
Number
30010
RUNNING
This signal signifies that the job is running. (Signifies that the job is running, system
status is waiting reserved start, or test run is running.) This signal status is the same
status as [START] in the programming pendant.
30011
SERVO IS ON
This signal signifies that the servo power is turned ON, internal processing such as
current position creation is complete, and the system is able to receive the START
command. This signal turns OFF when the servo power supply turns OFF. It can be
used for DX200 status diagnosis for an external start.
30012
30013
ALARM/ERROR OCCURRED
This signal signifies that an alarm or an error occurred. If a major error occurs, this
signal remains ON until the main power is turned OFF.
30014
BATTERY ALARM
This signal turns ON to notify that the battery requires replacing when the voltage
drops from the battery for backup memory of the encoder. Major problems may result
if memory data is lost because of an expired battery. It is recommended to avoid these
problems by using this signal as a warning signal.
30015 to
30017
30020
IN CUBE 1
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 1).
Use this signal to prevent interference with other manipulators and positioners.
30021
IN CUBE 2
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 2).
Use this signal to prevent interference with other manipulators and positioners.
30022
30057
30023
INTERMEDIATE START OK
This signal turns ON when the manipulator operates. It turns OFF when the currently
executed line is moved with the cursor or when editing operation is carried out after
HOLD is applied during operation. Therefore, this signal can be used as a restart
interlock after a HOLD is applied. However, it also turns ON in the teach mode and
TEACH MODE SELECTED signal must be referred together.
30024
IN CUBE 3
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 3).
Use this signal to prevent interference with other manipulators and positioners.
30025
IN CUBE 4
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 4).
Use this signal to prevent interference with other manipulators and positioners.
30050
WELD ON/OFF
Outputs a signal input from the interlock panel, etc.considering the robot status.
3)
14-73
RE-CTO-A220
165292-1CD
DX200 Controller
Number
30051
30052 to
30056
4)
WELDING COMMAND
This signal outputs execution command signal to the Power Source. This signal is not
necessary for a Power Source which is executed using the WELDING CONDITION
signal.
4)
STROKE CHANGE1
SINGLE SOLENOID
DOUBLE SOLENOID
This is a signal, when a double stroke gun is used, to change the open stroke of the
welding gun.
4)
4)
4)
Pseudo Input
Signal 8202x
7 6 5 4 3 2 1 0
0 0 0 1 1 1 1 1
Timer Cooling Water Error Validating (or IN09)
Gun Cooling Water Error Validating (or IN10)
Transthermo Error Validating (or IN11)
Low Air Pressure Validating (or IN12)
Weld ON/OFF Validating (or OUT09)
14-74
RE-CTO-A220
165292-1CD
DX200 Controller
14.13.5.1
Arc Welding
This circuit board is a welder I/F circuit board for the welding, and it is an
optional for the DX200. It is necessary to use this circuit board when
operating the instructions by the analog instruction to the welder.
DX200
MR Connector
Logical Connector
Number
Pin No.
Name
Signal
IN
IN
1
2
3
IN
CN322-1
Each point
24 VDC
5mA MAX
A/D +5V
IN
IN
IN
IN
CN322-9
8
10
IN
IN
11
12
IN
13
DC24V
5mA MAX
IN
14
DC24V
0.5A MAX
OUT
15
OUT
16
OUT
17
OUT
18
OUT
19
OUT
20
OUT
OUT
21
22
CN322-23
Detector
24
CN322-25
25
IN
26
IN
27
CN322-28 CH2 -G
IN
28
D/A 14V
3
17BYTE 32BYTE
DC24V
0.5A MAX
Welder
29
30
OUT
31
CN322-32 CH1-G
OUT
32
OUT
33
CN322-34 CH2 -G
OUT
34
CN322-30 024VU
D/A 14V
23
CN322-24
CN322-29 +24VU
SW2
1
CN322-10
A/D +5V
MS Connector
CN321-1 +24VU
OUT
OUT
CN321-5 024VU
WAGO Connector(231-105/026-A0)
MRP-34M01 Housing
MRP-M113 Contactor
MR-34L+ Casing
MS3106 A, 20-29P
MS3106 A, 20-29S
14-75
RE-CTO-A220
165292-1CD
DX200 Controller
14.14
SUPPLEMENT
For the models which are not in Table 14-10, Table 14-11(a)
and Table 14-11(b), refer to DX200 INSTRUCTIONS
SUPPLEMENT FOR Controller Specification List: ANSI
Specification (171270-1CD).
MA1440/MH12
Type
ERER-MA1440/MH12-A00
600mm730mm520mm
Breaker
NF32-SVF 3P 15A
JZNC-YPS21-E
CPU unit
JZNC-YRK21-1E
CPU circuit board
JANCD-YCP21-E
JANCD-YBB21-E
JANCD-YIF01- E
JANCD-YSF21-E
JANCD-YSF22 -E
JANCD-YIO21-E
Power ON unit
JZRCR-YPU51-1
SRDA-EAXA21A
JANCD-YBK21-3E
Converter
SRDA-COA30A21B-E
Capacitor module
SRDA-CUA662AA
Amplifier module
Regenerative
resistor
AMP1
SRDA-SDA14A01A-E
AMP2
SRDA-SDA21A01A-E
AMP3
SRDA-SDA14A01A-E
AMP4
SRDA-SDA06A01A-E
AMP5
SRDA-SDA06A01A-E
AMP6
SRDA-SDA06A01A-E
Type
SMVK500W6R0J A6103
Rated value
500W
Resister value
6
4715MS-22T-B50-B00 or
11938MB-B2N-EA-01
4715MS-22T-B50-B00 x3 or
11938MB-B2N-EA-01 x3
Circulation fan
Cooling fan
14-76
RE-CTO-A220
165292-1CD
DX200 Controller
MS210/MH225
Type
ERER-MS210/MH225-A00
600mm730mm520mm
Breaker
NF32-SVF 3P 30A
JZNC-YPS21-E
CPU unit
JZNC-YRK21-1E
CPU circuit board
JANCD-YCP21-E
JANCD-YBB21-E
JANCD-YBB22-E
JANCD-YIF01- E
JANCD-YSF21-E
JANCD-YSF22 -E
JANCD-YFC22-E
JANCD-YIO21-E
Power ON unit
JZRCR-YPU51-1
SRDA-EAXA21A
JANCD-YBK21-3E
Converter
SRDA-COA30A21B-E
Capacitor module
SRDA-CUA133AA
Amplifier module
Regenerative
resistor
AMP1
SRDA-SDA71A01A-E
AMP2
SRDA-SDA71A01A-E
AMP3
SRDA-SDA71A01A-E
AMP4
SRDA-SDA35A01A-E
AMP5
SRDA-SDA35A01A-E
AMP6
SRDA-SDA35A01A-E
Type
SMVK500W2R0J A5978 x3
Rated value
1500W
Resister value
Heat exchanger
TCSIP-16A4Y-0C
Cooling fan
4715MS-22T-B50-B00 x3 or
11938MB-B2N-EA-01 x3
14-77
RE-CTO-A220
165292-1CD
DX200 Controller
MS165/MH180
Type
ERER-MS165/MH180-A00
600mm730mm520mm
Breaker
NF32-SVF 3P 30A
JZNC-YPS21-E
CPU unit
JZNC-YRK21-1E
CPU circuit board
JANCD-YCP21-E
JANCD-YBB21-E
JANCD-YBB22-E
JANCD-YIF01- E
JANCD-YSF21-E
JANCD-YSF22 -E
JANCD-YFC22-E
JANCD-YIO21-E
Power ON unit
JZRCR-YPU51-1
SRDA-EAXA21A
JANCD-YBK21-3E
Converter
SRDA-COA30A21B-E
Capacitor module
SRDA-CUA133AA
Amplifier module
Regenerative
resistor
AMP1
SRDA-SDA71A01A-E
AMP2
SRDA-SDA71A01A-E
AMP3
SRDA-SDA71A01A-E
AMP4
SRDA-SDA35A01A-E
AMP5
SRDA-SDA35A01A-E
AMP6
SRDA-SDA35A01A-E
Type
SMVK500W2R0J A5978 x3
Rated value
1500W
Resister value
Heat exchanger
TCSIP-16A4Y-0C
Cooling fan
4715MS-22T-B50-B00 x3 or
11938MB-B2N-EA-01 x3
14-78
RE-CTO-A220
165292-1CD
DX200 Controller
14-79
RE-CTO-A220
165292-1CD
DX200 Controller
Appendix A
A.1
Equipment Configuration
The DX200 NAS is comprised of individual units and modules (circuit
boards). Malfunctioning components can generally be easily repaired after
a failure by replacing a unit or a module.
This section explains the configuration of the DX200 NAS equipment.
Small Capacity
Capacitor unit
165539-1
Machine PC
safety board
166927-1
Disconnect
Switch
166702-1
ServoPack
167284-1
Converter module
164291-1
Contactor
Power On/Off
164288-1
Machine CPU
safety board
164282-1
Power supply
164279-1
I/O NPN board
164287-1
I/O machine
safety board
164283-1
Transformer
159437-1
Regenerative resistor
149500-3
Inside Controller
Back View
Inside Controller
Right Side
Inside Controller
Front View
A-1
RE-CTO-A220
165292-1CD
DX200 Controller
Capacitor unit
165539-2
Machine PC
safety board
166927-1
Disconnect
Switch
166702-1
ServoPack
167284-2
Converter module
164291-1
Contactor
Power On/Off
164288-1
Machine CPU
safety board
164282-1
Power supply
164279-1
I/O NPN board
164287-1
I/O machine
safety board
164283-1
Transformer
159437-2
Regenerative resistor
152661-1
Inside Controller
Back View
A.1.2
Inside Controller
Right Side
Inside Controller
Front View
Back Side
Air Intake
A-2
RE-CTO-A220
DX200
INSTRUCTIONS
HEAD OFFICE
2-1 Kurosakishiroishi, Yahatanishi-ku, Kitakyushu 806-0004, Japan
Phone +81-93-645-7703
Fax +81-93-645-7802
YASKAWA America Inc. (Motoman Robotics Division)
100 Automation Way, Miamisburg, OH 45342, U.S.A.
Phone +1-937-847-6200
Fax +1-937-847-6277
YASKAWA Europe GmbH
Robotics Divsion )
Yaskawastrasse 1, 85391 Allershausen, Germany
Phone +49-8166-90-100
Fax +49-8166-90-103
YASKAWA Nordic AB
Bredbandet 1 vn. 3 varvsholmen 392 30 Kalmar, Sweden
Phone +46-480-417-800
Fax +46-480-417-999
YASKAWA Electric (China) Co., Ltd.
22/F One Corporate Avenue No.222, Hubin Road, Huangpu District, Shanghai 200021, China
Phone +86-21-5385-2200
Fax 86-21-5385-3299
YASKAWA SHOUGANG ROBOT Co. Ltd.
No7 Yongchang North Road, Beijing E&T Development AreaChina 100176
Phone +86-10-6788-2858
Fax +86-10-6788-2878
YASKAWA India Private Ltd. (Robotics Division)
#426, Udyog Vihar, Phase- IV,Gurgaon, Haryana, India
Phone +91-124-475-8500
Fax +91-124-475-8542
YASKAWA Electric Korea Co., Ltd
9F, KyoboSecuritiesBldg., 26-4, Yeouido-dong,Yeongdeungpo-gu, Seoul 150-737, Korea
Phone +82-2-784-7844
Fax +82-2-784-8495
YASKAWA Electric Taiwan Corporation
12F, No.207, Sec. 3, Beishin Rd., Shindian District, New Taipei City 23143, Taiwan
Phone +886-2-8913-1333
Fax +886-2-8913-1513
YASKAWA Electric (Singapore) PTE Ltd.
151 Lorong Chuan, #04-02A, New Tech Park, Singapore 556741
Phone +65-6282-3003
Fax +65-6289-3003
YASKAWA Electric (Thailand) Co., Ltd.
252/125-126 27th Floor, Tower B Muang Thai-Phatra Complex Building,
Rachadaphisek RoadHuaykwang, Bangkok 10320, Thailand
Phone +66-2693-2200
Fax +66-2693-4200
PT. YASKAWA Electric Indonesia
Secure Building-Gedung B Lantai Dasar & Lantai 1 JI. Raya Protokol Halim Perdanakusuma,
Jakarta 13610, Indonesia
Phone +62-21-2982-6470
Fax +62-21-2982-6741
MANUAL NO.
RE-CTO-A220