The document provides preliminary specifications for an MVC 4000 evaporator, including its estimated dimensions, capacities, electrical connections, and chemical usage. It has an operating volume of 5,000 gallons, weighs 150,000 pounds dry and 187,000 pounds operating. It requires 30-40 PSI of steam for start-up and has electrical needs of 2,030 amps at full load. Chemical usage is estimated at 30-50 PPM of anti-scalant and 200-600 PPM of anti-foam.

Uploaded by

Pragathees Waran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views1 page

MVC 4000 Preliminary Specifications - 1

The document provides preliminary specifications for an MVC 4000 evaporator, including its estimated dimensions, capacities, electrical connections, and chemical usage. It has an operating volume of 5,000 gallons, weighs 150,000 pounds dry and 187,000 pounds operating. It requires 30-40 PSI of steam for start-up and has electrical needs of 2,030 amps at full load. Chemical usage is estimated at 30-50 PPM of anti-scalant and 200-600 PPM of anti-foam.

Uploaded by

Pragathees Waran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ENCON

ENERGY CONSCIOUS INNOVATION

MVC 4000 EVAPORATOR


PRELIMINARY SPECIFICATIONS
Estimated Dimensions
Length
Width
Height

1040
288
408

Inches
Inches
Inches

Estimated Capacities
Operating Volume
Dry Weight
Operating Weight
Feed Inlet*
Residue Outlet*
Distillate Outlet*
Steam Inlet Pressure system requires a 261 HP boiler for

5,000
150,000
187,000
68.67
2
66.67
30-40

Gallons
Lbs
Lbs
GPM
GPM
GPM
PSI

start-up and it is not included in price

Start Up Steam Volume


9,467 x 1-2 hrs LBS/HR
Compressed Air Pressure
100
PSI
Compressed Air Volume (Peak)
220
ACFM
* Assumes 97% Reduction in Volume will need to be confirmed with water samples prior to
beginning design/build phase
Estimated Electrical Connections at 480 V/3 PH/60 Hz
Full Load Amps
2,030
Evaporator Skid Breaker
180
Blower 1 Breaker
1800
Blower 2 Breaker
1800
Recirculation Pump Breaker
700

Amps
Amps
Amps
Amps
Amps

Estimated Chemical Usage**


Anti-Scalant
30-50
PPM
Anti-Foam
200-600
PPM
** Esimates only due to no sample available for testing; actual volumes and recommended
chemistry may change in full-scale operation.