Comparing Total Load From Pipe Reaction Direction Y With Manual Weight Calc

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

COMPARING TOTAL LOAD FROM PIPE REACTION DIRECTION Y WITH MANUAL WEIGHT CALC

MANUAL CAL =
TOTAL Fy =
=

136339.39
-1505395
-153455.1478

Current Contigencies C1 =

1.125537879

Expected Removable item =

kg
N
kg

1.125537879

MANUAL CAL deduct removable =


After contigencies =
Total load taken direction Y =

62446.16 kg
70285.52 kg
-691440.60 N

Fixed on Skid during lifting


Total Load from piping with contigencies =
153455.15
Bare Load from Piping =
62446.16 kg

73893.23

83169.62935 kg

83169.62935

70285.51846 kg

689500.9361 N

To get 15% Contigencies as per weight datasheet (Fy)


=
=
=
=

(Total piping load value fixed during lifting/C1) x 1.15


71813.084 kg
704486.354 N
FOLLOWING SPECIFICATION OF API-RP2A : DYNAMIC AMPLIFICATION FACTOR FOR NON-RELATED TO
LIFTING EQUIPMENT : DAF = 1.20
All value from piping reaction will be consider the same DAF= 1.20
To get 1.20 DAF factor for the piping :

Fy x 1.20 = New Value need to be consider


for total =

86175.7008 kg

or

845383.6248 N

>>>> ALL THE VALUE SHOWN IN PIPE STRESS NEED TO RE-CALCULATE


=

("F(X,Y,Z)" / C1) x 1.15 x 1.20

Source
Node

From Piping
20

Structural
143

PS-1

LIFTING
DAF

Fx
3480
4266.76

Fy
-126554
-155165.39

Fz
537
658.41

Source
Node

From Piping
55

Structural
153

PS-2A

LIFTING
DAF

Fx
1305
1600.04

Fy
-121101
-148479.57

Fz
829
1016.42

REMOVABLE
N
SUS

REMOVABLE
N
SUS

Source
Node

From Piping
80

Structural
154

PS-6

LIFTING
DAF

Fx
7852
9627.18

Fy
-116764
-143162.06

Fz
871
1067.92

Source
Node

From Piping
85

Structural
155

PS-2

LIFTING
DAF

Fx
-323
-396.02

Fy
-28343
-34750.80

Fz
274
335.95

Source
Node

From Piping
103

Structural
156

PS-3

LIFTING
DAF

Fx
96
117.70

Fy
-22227
-27252.09

Fz
9085
11138.94

Source
Node

From Piping
105

Structural
157

PS-2

LIFTING
DAF

Fx
61
74.79

Fy
-43530
-53371.28

Fz
-30
-36.78

Source
Node

From Piping
125

Structural
158

PS-5

LIFTING
DAF

Fx
25
30.65

Fy
-73346
-89928.10

Fz
-63
-77.24

Fx
20.91
25.64

Source
Node

From Piping
145

Structural
159

PS-2A

REMOVABLE

LIFTING
DAF

Fx
-366
-448.75

Fy
-129160
-158360.55

Fz
-78
-95.63

Source
Node

From Piping
180

Structural
160

PS-1

LIFTING
DAF

Fx
-979
-1200.33

Fy
-127413
-156218.59

Fz
-130
-159.39

Source
Node

From Piping
225

Structural
152

PS-2A

LIFTING
DAF

Fx
-894
-1096.12

Fy
-121245
-148656.13

Fz
-307
-376.41

REMOVABLE 0.16% ONLY


Fx
6567.13
8051.83

Fy
-97657.16
-119735.54

Fz
728.47
893.17

N
SUS

N
SUS

Mx
9785
11997.20

My
94
115.25

Mz
3971
4868.77

N
SUS

N
SUS

REMOVABLE 0.16% ONLY


Fy
-61343.93
-75212.59

Fz
-52.69
-64.60

N
SUS

N
SUS

REMOVABLE
N
SUS

REMOVABLE
N
SUS

Source
Node

From Piping
250

Structural
151

PS-6

LIFTING
DAF

Fx
-2039
-2499.98

Fy
-94488
-115849.89

Fz
-328
-402.15

Source
Node

From Piping
275

Structural
150

PS-2

LIFTING
DAF

Fx
775
950.21

Fy
-47855
-58674.08

Fz
-154
-188.82

Source
Node

From Piping
277

Structural
149

PS-3

LIFTING
DAF

Fx
-160
-196.17

Fy
-13693
-16788.72

Fz
-2633
-3228.27

Source
Node

From Piping
295

Structural
148

PS-2

LIFTING
DAF

Fx
-272
-333.49

Fy
-39242
-48113.85

Fz
49
60.08

Source
Node

From Piping
297

Structural
147

PS-2

LIFTING
DAF

Fx
-125
-153.26

Fy
-48845
-59887.90

Fz
155
190.04

Fx
-104.55
-128.18

Source
Node

From Piping
315

Structural
146

PS-2A

REMOVABLE

LIFTING
DAF

Fx
1284
1574.29

Fy
-133918
-164194.24

Fz
186
228.05

Source
Node

From Piping
445

Structural
93

PS-4

LIFTING
DAF

Fx
-16175
-19831.85

Fy
-169662
-208019.26

Fz
-3937
-4827.08

Source
Node

From Piping
465

Structural
161

PS-4

LIFTING
DAF

Fx
10598
12994.00

Fy
-48009
-58862.90

Fz
-3592
-4404.08

TOTAL DAF Fy =

-847761.81 N

REMOVABLE 0.16% ONLY


Fx
-1705.35
-2090.89

Fy
-79026.33
-96892.64

Fz
-274.33
-336.35

N
SUS

N
SUS

Mx
4748
5821.43

My
276
338.40

Mz
909
1114.51

N.m
SUS

N
SUS

REMOVABLE 0.16% ONLY


Fy
-40852.18
-50088.06

Fz
129.64
158.94

N
SUS

N
SUS

N
SUS

N
SUS

OK