This document provides instructions for checking the status of alarms, blocks, and other issues in BTS sites and components within a BSC. It describes commands to check the status of alarms, blocks, units, TRXs, channels, LAPD, ET, and G.826. It also provides troubleshooting steps for various common issues like blocked TRXs, sites offline, performance issues, and alarms. These include resetting and locking/unlocking components, checking configurations, and escalating to engineers when needed.

Uploaded by

Biorn Opalia
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views

Command OSS

This document provides instructions for checking the status of alarms, blocks, and other issues in BTS sites and components within a BSC. It describes commands to check the status of alarms, blocks, units, TRXs, channels, LAPD, ET, and G.826. It also provides troubleshooting steps for various common issues like blocked TRXs, sites offline, performance issues, and alarms. These include resetting and locking/unlocking components, checking configurations, and escalating to engineers when needed.

Uploaded by

Biorn Opalia
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

BTS PART

Mengetahui BTS2 yang sudah ada dalam BSC


ZEBP;
ZEEP;

CHECK STATUS UNIT YANG BLOCK DALAM BTS DI SATU BSC


ZEEL:BL; hal ini maka semua alarm blocking di BTS akan diprint
Berikut alarm block dalam BTS ;;
Daily BTS cmd

ZEEL:BL-RST;
ZEEL:BL-RSL;
ZEEL:BL-TRX;
ZEEL:BL-CLK;
ZEEL:BL-SYS;
ZEEL:BL-TSL;
ZEEL:BL-FTY;
OR LANGSUNG < ZEEL:BL; >
ZAHO::NR=4000&4001&4002&4003&4004&4005&4006&4007&4008&4009;
BL
=
BL-BCF=
BL-BTS=
BL-CF =
BL-CLK=
BL-CU =
BL-DGN=
BL-FLO=
BL-FTY=
BL-FU =
BL-PWR=
BL-RSL=
BL-RST=
BL-SHD=
BL-SU =
BL-SWO=
BL-SYS=
BL-TRX=
BL-TSL=
BL-TST=
BL-USR=
BL-WAC=

blocked
blocked-bcf_fault
blocked-bts_fault
blocked-cu/fu_fault
blocked-clock_fault
blocked-cu_fault
blocked-diagnostic
blocked-floating
blocked-faulty
blocked-fu_fault
blocked-mains_power_fault
blocked-rsl_fault
blocked-reset
blocked-shutting_down
blocked-bcsu_reset
blocked-background_data_switchover
blocked-system
blocked-trx_fault
blocked-timeslot_fault
blocked-testing
blocked-user
blocked-waiting for autoconfiguration

CHECK STATUS ALARM ACTIVE DI SITE


ZEOL:<BCF identification>:NR=<BTS alarm number>,CLS=<alarm class>;

BIASANYA MENGGUNAKAN BCF ID ATAU ALARM NUMBER SAJA


ZEOL:BCF id;
ZEOL:NR;

CHECK STATUS ALARM HISTORY DI SITE


ZEOH:
[ <date>
| <current> def ], [ <time> | 00-00-00 def]:[
BCF = <BCF
identification> | <all> def ] | [ OBJ = <object type> | <all> def ] | [ STA =
<current state of object> | <all> def ] | [ NR = <BTS alarm number> | <all>
def ] | [ CLS = <alarm class> | <all> def ]]... ;

Untuk mengetahui semua alarm di BCF cukup dengan


ZEOH: YYYY-MM-DD: HH-MM-SS:BCF ID,:;

Atau diikuti alarm number


ZEOH: YYYY-MM-DD: HH-MM-SS:BCF ID,NR=xxxx:;

CHECK STATUS BTS-SITE


ZEEI: [ [ BCF = <BCF identification> ... | SEG = <SEG identification> ...
<option> | SEGNAME = <SEG name> ... <option> | BTS = <BTS identification> ...
| NAME = <BTS name> ... ] | <all> def ]:[ <output type> | <NORM> def ];

BIASANYA MENGGUNAKAN BCF ID


ZEEI:bcf id;
EXAPMPLE Print out
ZEEI:BCF=1;
ET PCM

BSC3i
KAYUN
2007-04-16
RADIO NETWORK CONFIGURATION IN BSC:

09:23:41

F
ADM OP
R ET- BCCH/CBCH/
LAC
CI
HOP STA STATE FREQ T PCM ERACH
===================== === ====== ==== == ==== ===========
BCF-001 ULTRASITE
16906 63291 BTS-001
SANGKAPURA1
RF
EDGE TRX-001
EDGE TRX-002
16906 63292 BTS-002
SANGKAPURA2
RF
EDGE TRX-005
EDGE TRX-006
16906 63293 BTS-003
SANGKAPURA3
RF
EDGE TRX-009
EDGE TRX-010

E
T
R
X
=

P
R
E
F
=

B
C
S
U
=

U
U

WO
WO

U
U
U

WO
WO
WO

1
29

U
U
U

WO
WO
WO

7
33

0
0

34
34 MBCCH+CBCH

0
0

U
U

WO
WO

13
35

0
0

34
34 MBCCH+CBCH

0
P 0

D-CHANNEL BUSY
O&M LINK HR FR
NAME ST
/GP
===== == === ===

0 OM001 WO
0
0

34
34 MBCCH+CBCH

0
0

3
0

0
P 0

2
0

HR or FR more detail
chek dgn ZERO:BTS is,
TRX id;
Trafik GPRS

Check apakah ada status TRX,BTS atau Site dan OMU dalam kondisi tidak
WO ?
Jika ya
1. Hanya 1 TRX dalam satu sektor
BL-TRX or BL-SYS;
Check alarm history atau current alarm
- Jika ada masalah dengan HW maka coba reset dengan cara Lockunlock TRX ( ZERS:BTS id:TRX id:L/U; )
- Jika problem masih ada coba disable-enable LAPD di TRX tsb.
ZDTC:NAME LAPD:BL/WO;
Jika
not
solve
report
ke
engineer
area
bersangkutan
( coordinator area ) atau all bss biar semua tahu untuk difollow
up nantinya
2. 2 TRX dalam satu base-band yang sama
( ZERS:BTS id:TRX id:L/U; )
- Jika problem masih ada coba disable-enable LAPD di TRX tsb.
ZDTC:NAME LAPD:BL/WO;
- Jika problem masih ada check alarm di ZEOL apakah ada masalah
berhubungan dengan combiner, baseband atau multicoupler, lalu
request engineer to site reset-replace proble di HW tsb.
3. Jika semua TRX blocking dalam satu sector
Coba check ZEOL atau ZEOH dan P3knya, reset BTS (ZEQS:BTS id:L;)
Jika problem masih ada report ke coordinator area atau
koordiantor BSS or all bss

4. Jika satu site off atau block termasuk OMU maka coba check alarm ET.
Dari printout ZEEI:BCF id; diketahui ET-PCM.
-Coba check alarm history BTS tsb
ZEOL:bcf id;
Apakah ada alarm environment seperti main failure, major rectifier.
Jika ada maka itulah penyebabnya dan harus ada engineer on site.
- Jika tidak ada alarm diatas check sbb;
ZAHO:ET,et pcm;
Apakah ada AIS atau PCM Failure?
Jika ada maka ada masalah transmisi di BTS tsb;
CHECK STATUS LAPD DI PCM SITE
ZDTI:::PCM=ET PCM,;
EXAMPLE PRINT OUT
ZDTI:::PCM=34,;
BSC3i

KAYUN

2007-04-16

09:30:18

INTERROGATING D-CHANNEL WORKING STATE

OMU SITE
Harus kondisi
WO biar Site
bisa diremote
atau
dimonitor
LAPD TRX
Kondisi /
working state
harus WO-EX

NAME
----OM001
T0011
T0012
T0015
T0016
T0019
T001A

NUM
--4
5
6
7
8
9
10

UNIT
-----BCSU-0
BCSU-0
BCSU-0
BCSU-0
BCSU-0
BCSU-0
BCSU-0

INTERFACE
SIDE
--------NETW
NETW
NETW
NETW
NETW
NETW
NETW

EXT
SUB
PCM-TSL-TSL
----------34-31-00
34-28-00
34-28-04
34-29-00
34-29-04
34-30-00
34-30-04

SAPI
---62
0
0
0
0
0
0

WORKING
STATE
------WO-EX
WO-EX
WO-EX
WO-EX
WO-EX
WO-EX
WO-EX

OMU Merupakan FUNGSI MAINTENANCE DAN INTERFACE KE BSC sehingga Status harus dalam WO-EX.

- Jika hanya ada alarm Fault rate saja bisa saja koneksi kabel di DDF
tidak bagus.
CHECK STATUS G.826 PCM , Overview G.826 ada di file G.826.pdf
ZYMO:ET,ET NUMBER;
CONTOH PRINT OUT
< YMO:ET,034;

LOADING PROGRAM VERSION 6.2-0


BSC3i

KYN02

2007-05-07

16:42:37

PCM STATISTICS
PERMANENT MEASUREMENT
UNIT
ET-34

START TIME
2007-05-07 00:00

DISTURBANCES:
DISTTYPE
NOINSGN
FALOST
AIS
REMOTE

COUNTER LIMITS (MS)


10-50
50-200
0
0
0
0

200-1000

0
0
0
0

1000-

0
0
0
0

0
0
0
0

FRAME ALIGNMENT SIGNAL ERRORS:


COUNTER LIMITS (ERRORS/ 5 SEC)
1-39
40-79
80-159
0

160-

SLIPS:
POSITIVE
0

NEGATIVE
0

CRC PERFORMANCE MONITORING:


TOTAL
TIME

AVAIL
TIME

UNAVAIL
TIME

LOCAL END
REMOTE END

16:42:25
16:42:25

16:42:25
16:42:25

00:00:00
00:00:00

(%)

EFS

ES

SES

DM

LOCAL END
REMOTE END

100.00
100.00

0.00
0.00

0.00
0.00

0.00
0.00

5. Jika banyak BTS atau site off dala waktu bersamaan bisa dicheck ZEEL:BL;
dan ZEOL:BCF id; dimana matinya bersamaan maka coba check transmisi via
OSS Connection Tools dan check apakah link2 BTS tsb dalam HOP yang sama
dalam TRS di excel.
6. Jika ada site off tapi ET ok dan transmisi ok maka coba reset OMU dulu
baru reset site.
ZEFR:bcf id:OMU; ( hal ini untuk update status OMU ke BSC )
Jika masih belum naik maka reset site
ZEFR:bcf id:site;
7. Jika ada alarm block per channel / Time slot cukup dengan lock unlock
channel di TRX ;
ZERS:BTS=x,TRX=x,CH=x,:L;
ZERS:BTS=x,TRX=x,CH=x,:U;
Atau Lock-unlock TRX

CHECK STATUS 1 TRX DALAM SEKTOR


ZERO:bts id:TRX id;
atau semua TRX dalam sektor
CHECK STATUS semua TRX DALAM SEKTOR
ZERO:bts id:;
8. Jika site off
reset ET : 1.
2.
3.
4.

karena ET failure dengan mengetahui dari ZAHO maka coba


ZUSC:ET,et number:BL:fcd; buat status block
ZUSC:ET,et number:TE:fcd; buat status Test
ZUDU:ET,ET NUMBER:::;
Check status diagnose sampai mana
ZUDH; jika sudah ada informasi no diagnostic
5. Check hasil diagnostic
ZUDH:ET,NOMER ET::YYYY-MM-DD,:; ATAU CUKUP
DENGAN
ZUDH:ET,NOMER ET:::;
9. Dari ZEOL dan ZEEL jika ada masalah berhubungan dengan performansi TRX,
sektor maupun Site.
- Masalah performansi di site

Contoh : 7124, 7125, 7126, 7127-7138, 7508,7511, 7538, 7601, 7604, 7606 dan lihat
detailnya di alarm printout.
-

contoh 7743/7745 = mean holding time below threshold artinya call


tidak pernah berhasil diatas 4 detik di timeslot atau channel TRX
tertentu
Coba check via service terminal
ZDDS:; lalu ketik ? apakah indek Radio Resource Monitoring ada ?
Jika belum aktifkan sbb : ZLE:index,E00_BXSX; pilih index yang
belum ada saya buat disini N sebagai index
CONTOH;
1. Untuk bisa execute setelah mengaktifkan service terminal
diataslalu ketik ? dan ketik index diikuti enter.
2. CHECK eaktu pendudukan; ( ditandai dengan OCCU or occupancy
hitungan dalam hexa & nanti deterjemahkan dalam detik / decimal
TC:BTS id dalam hexa,TRX id dalam hexa;
00-MAN>?
DX200 SERVICE TERMINAL MAIN LEVEL COMMANDS:
?
A
B
C
D
E

.....
.....
.....
.....
.....
.....

MENU / HELP
ANALYZER
DEFINE ENVIRONMENT
COMMAND LANGUAGE UTILITIES
MEMORY AND I/O HANDLING
EXIT DEBUGGER SESSION

I
L
O
R
S
T

.....
.....
.....
.....
.....
.....

GENERAL INFORMATION
EXTENSION HANDLING
OPERATING SYSTEM COMMANDS
REMOTE DEBUGGER HANDLING
SYSTEM MONITORING COMMANDS
TERMINAL HANDLING

INDEX

EXTENSIONS:
G ..... COMPUTER LOG HANDLER
M ..... MASS MEMORY HANDLING

00-RRM>TC:4,1

(DEF)

P ..... BCF PHASE MONITORING


N ..... RADIO RESOURCE MON

(LOA)
(LOA)

Contoh print out


2007-05-10
DX 200 BSC

11:54:32.13
RADIO CHANNEL INFORMATION FOR BTS NUMBER 04

TRX 02 N-TRX REGULAR


PCM 01E0 ARFCN 0001 LINK ID 0044 BITRATE 0020
TSL _CONFIG ____ STATE __ STATUS _______ IF-LVL ___ CALL TIME TIME ___ USAGE
FR,HR0 HR1
F0 H0 H1
FR,HR0
HR1
-00 PERM FR
WORKING IDLE
00
00000000
CSW
-01 PERM FR
WORKING OCCU
00
000000BA
CSW
-02 PERM FR
WORKING IDLE
00
00000000
CSW
-03 PERM FR
WORKING IDLE
00
00000000
CSW
-04 PERM FR
WORKING OCCU
00
00000028
CSW
-05 PERM FR
WORKING IDLE
00
00000000
CSW
-06 PERM FR
WORKING OCCU
00
00000009
CSW
-07 PERM FR
WORKING OCCU
00
00000000
CSW

Oendudukan dalam
hexa , CSW =
circuit switch

> Coba check apakah hanya 1 TRX atau 2 TRX dibaseband yang sama
Jika hanya 1 TRX coba reset atau lock-unlock TRX.
Jika alarm masih muncul coba info ke engineer areanya untuk
check HW di site tsb untuk check konfigurasi baik mencocokkan
mapping timeslot di BTS manager dengan BSC via
ZDSB:NAME=T0BCFidTRXid; CHECK lapd name bisa dilihat dari
DTI:::PCM=; dan ZERO:BTS=X,TRX=X:; CHECK TIMESLOT TRX
Jika semua sama coba langkah dibawah
Reset TRX jika masih lakukan dibawah
On site check konfigurasi dan jika ok coba dibawah
Replace HW diTRX maupun baseband.
Jika ada alarm ditrx di baseband yang sama maka perlu ganti
Baseband or lainnya disite.
> 7745 / channel failure
Masalah ini call akan selalu fail bisa dilakukan langkah seperti
7743 diatas
> 7604 / bts operation degrade
> Coba check via BTS manager di OSS , check RSSI di Site tsb
apakah ada perbedaan signal level di main diversity lebih dari
10 dB jika hanya 1 TRX saja coba info ke engineer check dan
replace TRX.
> Jika ada banyak TRX dalam sector yang sama RSSInya beda 10 dB
antara main dan diversity maka coba check DVJA atau multicoupler
dan kablenya ke site.
> 7601 / bcf operation degrade
Coba check sinkronisasi BTS di E-1/T1 atau RRI apakah
sinkronisasi primer tidak ekternal ? jika belum ganti ke
ekternal

> 7738 BTS WITH NO TRANSACTIONS


Contoh printout
KYN02
BCF-025
BTS-025
QUAL
** ALARM TUNJUNGANPZ2
(18009) 7738 BTS WITH NO TRANSACTIONS

2007-05-07

12:00:09.97

10
10 = tidak ada trasaksi GPRS
Coba check pakai ZEEI atau ZERO disektor tsb apakah memang GP
idle semua ? Coba check ZEQO:bts id:GPRS:;

PRINT OUT
BSC3i

KYN02

GPRS PARAMETERS:
================
SEG-001
BBDTOWER1
BCF-001
BTS-001
BBDTOWER1
------------------------------------BTS ADMINISTRATIVE STATE ... UNLOCKED
BTS OPERATIONAL STATE ...... WO
BTS BACKGROUND DATA STATE .. NOT DEFINED
GPRS ENABLED.............................(GENA)...
NETWORK SERVICE ENTITY IDENTIFIER.....(NSEI)...
BSSGP VIRTUAL CONNECTION IDENTIFIER...(BVCI)...
BVCI OPERATIONAL STATE.........................
ROUTING AREA IDENTIFICATION..............(RAI)
MOBILE COUNTRY CODE...................(MCC)....
MOBILE NETWORK CODE...................(MNC)....
LOCATION AREA CODE....................(LAC)....
ROUTING AREA CODE........................(RAC)....
EGPRS ENABLED............................(EGENA)..
DEDICATED GPRS CAPACITY..................(CDED)...
DEFAULT GPRS CAPACITY....................(CDEF)...
MAX GPRS CAPACITY........................(CMAX)...
PREFER BCCH FREQUENCY GPRS...............(BFG)....
DL ADAPTION PROBABILITY THRESHOLD........(DLA)....
UL ADAPTION PROBABILITY THRESHOLD........(ULA)....
DL BLER CROSSPOINT CS SELECTION NO HOP...(DLB)....
UL BLER CROSSPOINT CS SELECTION NO HOP...(ULB)....
DL BLER CROSSPOINT CS SELECTION HOP......(DLBH)...
UL BLER CROSSPOINT CS SELECTION HOP......(ULBH)...
CODING SCHEME NO HOP.....................(COD)....
CODING SCHEME HOP........................(CODH)...
INITIAL MCS FOR ACKNOWLEDGED MODE........(MCA)....
INITIAL MCS FOR UNACKNOWLEDGED MODE......(MCU)....
MAXIMUM BLER IN ACKNOWLEDGED MODE........(BLA)....
MAXIMUM BLER IN UNACKNOWLEDGED MODE......(BLU)....
MEAN BEP OFFSET GMSK.....................(MBG)....
MEAN BEP OFFSET 8PSK.....................(MBP)....
EGPRS LINK ADAPTATION ENABLED............(ELA)....

Y
4343
10001
UNBLOCKEK
510
01
13372
3
Y
17 %
67 %
100 %
0
20 %
10 %
68 %
87 %
11 %
24 %
2
0
9
9
90 %
10 (1%)
0
0
1

Kondisi BVCI harus WO-EX


Biasnya unblock yg bikin
masalah tidak 17:15:33
bisa diduduki GPRSnya.
2007-05-07
1. Coba disable GPRS
ZEQV:BTS=BTS ID:GENA=N;
ZEQV:BTS=BTS ID:GENA=Y;
Jika masih unblock ulangi langkah diatas diikuti lock-unlock BTS
Jika maslaha belum selesai coba check BTS ini terhubung ke NSEI mana ? dengan
ZFWO:BCSU=0&&6:BTS;
Lalu ubah NSEI BTS yg bermasalah tsb dengana cara;
ZEQV:BTS=x:GENA=N;
ZEQV:BTS=x:GENA=Y,:NSEI=yg lainnya:;
Pemilihan NSEI dgn melihat load atau jumalah BTS yg terhubung ke NSEI
terendah.
2. Coba lock-unlock BTS
ZEQS:BTS id:L;
ZEQS:BTS id:U;
3. Jika belum solve BVCI tsb, coba recreate TRX yg sebelumnya dilog dulu
konfigurasi TRX ( ZERO: BTS=id,TRX=number; )
dan LAPDnya ( DTI:::PCM=number ) ; ZDSB:NAME=name;
- lock trx ( ZERS:BTS=id,TRX=number,:L; ) lalu delete TRX (ERD:BTS=id,TRX=number:; )
- LOCK ( DTC:id:BL; ) and DEACTIVATE LAPD ( DTC:id:AD; ) lalu delete LAPD
(DSD:id:; )
- Create Ulang TRX
> ZDSE:id:BCSU,x:0,y:32, pcm-tsl,sub-tsl;
> ACTIVATE LAPD ZDTC lalu diWOkan
> Create TRX ZERC: lalu data disamakan dengan ZERO sebelumnya
> Unlock TRXnya

CHECK PARAMETER DAN STATUS FUNGSI DI SEKTOR


DALAM OSS MAINTENANCE YANG PERLU DIPERHATIKAN ADALAH STATUS GPRS DAN
CELL-BARRED, STATUS GPRS HARUS KONDISI WO-EX DAN CELL BARRED HARUS N
ZEQO:BTS ID:GPRS;
Kondisi GENA HARUS Y dan BVCI dalam WO-EX;
Jika belum berhasil coba check kembali semua GPRS di semua BTS
ZEOL::NR=7738; ( BTS NO TRANSACTION DENGAN TAMBAHAN INFO 10 ) jika
banyak BTS ada alarm tsb check apakah BTS2 tsb dalam NSEI BCSU yang
sama ?
==================================================================
CHECK STATUS DAN ALARM BSC LEVEL PER HOURS
==================================================================
CHECK STATUS OMU ( OPERATION MAINTENANCE UNIT )
ZUSI:OMU;
CHECK ALARM OMU
ZAHO:OMU;
ZAHP:MB,:::;
CHECK STATUS MB ( MESSAGE BUS UNIT )
ZUSI:MB;
CHECK ALARM OMU
ZAHO:MB;
ZAHP:MB,:::;
CHECK STATUS BCSU ( CARD SIGNALLING UNIT )
ZUSI:BCSU;
CHECK ALARM BCSU
ZAHO:BCSU,0;
ZAHO:BCSU,1;
ZAHO:BCSU,2;
ZAHO:BCSU,3;
ZAHO:BCSU,4;
ZAHO:BCSU,5;
ZAHO:BCSU,6;

ZAHP:BCSU,0::;
ZAHP:BCSU,1::;
ZAHP:BCSU,2::;
ZAHP:BCSU,3::;
ZAHP:BCSU,4::;
ZAHP:BCSU,5::;
ZAHP:BCSU,6::;

CHECK STATUS MCMU ( MARKER / CARD SWITCHING UNIT )


ZUSI:MCMU;
CHECK ALARM MCMU
ZAHO:MCMU;
ZAHP:MCMU,:::;
CHECK STATUS CLOCK ( CLOCK UNIT )
ZUSI:CLS;
CHECK ALARM CLOCK
ZAHO:CLS;
ZAHP:CLS,:::;
CHECK STATUS TRANSCODER ( TRANSCODER UNIT )
ZUSI:TCSM;
CHECK ALARM TRACODER
ZAHO:TCSM,(lihat number dari ZUSI:TCSM; );

ZAHP:TCSM,0::;

CHECK CIRCUIT BSC-MSC via TC


ZCEL:CGR=1,;
ZCEL:CGR=1,FORM=EXT;
CHECK SINKRONISASI BSC ( 2M1 = ATER 32, 2M2 = ATER 96, 2M3 = ATER 160, 2M4 = ATER 224 )

ZDRI;
CHECK SIGALLING UTILIZATION EVERY HOURS
ZOLT;
CHECK SIGNALLING BSC-MSC
ZNET;
CHECK SCCP STATE BSC-MSC
ZNGI;
CHECK ROUTE SET STATE BSC-MSC
ZNRI:NA0;
CHECK STATUS GB LINK BSC-SGSN UNTUK GPRS BSC
ZFUI;
ZFWO:BCSU=0&&6:BTS;
Check External Alarm BSC dan OMU
ZAHO:OMU:NR=4000&4001&4002&4003&4004&4005&4006&4007&4008&4009;
ZAHO:OMU:NR=4010;
CHECK ALARM YG DICREATE DI BSC
ZWAT;

FLOW OF DAILY CHECKLIST IN BSC

1. CHECK LINK GB-LINK


ZFUI;
ZFWO:BCSU=0&&6:BTS;
Operation state harus WO dan AV-EX
2. CHECK LINK DARI PCM di ZFUI
ZAHP:ET,33:::;
ZAHP:ET,xx:::;
Ada 1 BSC yg hanya menggunakan PCM / ET-33 saja untuk
GB-Linkl tapi ada yg lain Bisa dilihat di ZFUI;
3. Jk ada history problem di ET tsb
Check
ZAHP:BCSU,0::;
ZAHP:BCSU,1::;
ZAHP:BCSU,2::;
ZAHP:BCSU,3::;
ZAHP:BCSU,4::;
ZAHP:BCSU,5::;
ZAHP:BCSU,6::;
Atau ZAHO:BCSU;
Karena Frame relay via E-1 dari SGSN ke BSC
dieksekusi oleh PCU di BCSU
Jika semua alarm baik 3025, 3020, 3031 hanya terjadi satu PCU
di BCSU tertentu maka kemungkinan BCSU bermasalah tapi
jika semua BCSU mengalaminya maka kemungkinan Link
masalah bisa dicheck di point-2 atau jika link dari ET tsb tidak
pernah masalah konfirmasi ke temen2 SGSN ( skrg by Nanang /
ahot )

SGSN

MSC

1. CHECK LINK A-TRUNK


a. ZCEL:CGR=1,;
b. ZCEL:CGR=1,FORM=EXT;
c. ZRCI:SEA=1:TYPE=CCS:PRINT=5;
ANALISA JIKA ADA MASALAH DI
HISTORYNYA, APAKAH ADA MASALAH
LINK ATAU HW PROBLEM DI TC or BSC.

BSC

TCSM

1. CHECK LINK ATER


ZUSI:TCSM;
ZAHO:TCSM;
ZAHP:TCSM,::;
ANALISA JIKA ADA MASALAH DI HISTORYNYA, APAKAH ADA
MASALAH LINK ATAU HW PROBLEM DI TC or BSC.
> jika ada HW problem check circuit di poin b sebelah apah blok system ?
lakukan segera perbaikan
> Cara buat TCSM tsb dalam kondisi TE atau Test (
ZUSC:TCSM,x:TE,FCD; ) Tapi circuit harus diblok dulu
ZCEC::ETPCM=40,CRCT=1-1&&-31&2-1&&-31&3-1&&-31&4-1&&XX:BL; xx = sampai dengan cara melihat di poin B.
> kemudian test TCSM tsb setelah kondisi TE ( ZUDU:TCSM,xyz:::; ) dan
lihat proses ZUDQ;
Jika sudah ada no diagnostic test berarti test selesai dan lihat hasilnya
ZUDH:TCSM,xyz:::;
Jika ada masalah koordinasi untuk penggantian HW. Jika tidak ada fault saat test
bisa jadi hang TRCO.
2. CHECK SIGNALLING LINK
ZNET;
ZNGI;
ZNRI:NA0;
ANALISA JIKA ADA MASALAH DI current printout, APAKAH ADA
MASALAH LINK ATAU HW PROBLEM DI TC or BSC.
3. CHECK SINKRONISASI

ZDRI;

CONTOH PERFORMANSI E-1 DI ET;


YMO:ET,32;
BSC3i

NK_SIER1

2007-08-15

15:12:58

PCM STATISTICS
PERMANENT MEASUREMENT
UNIT
ET-32

START TIME
2007-08-15 00:00

DISTURBANCES:
DISTTYPE
NOINSGN
FALOST
AIS
REMOTE

COUNTER LIMITS (MS)


10-50
50-200
0
0
0
0
0
0
0
0

200-1000
0
0
0
0

FRAME ALIGNMENT SIGNAL ERRORS:


COUNTER LIMITS (ERRORS/ 5 SEC)
1-39
40-79
80-159
0

10000
0
0
0

160-

SLIPS:
POSITIVE
0
CRC PERFORMANCE MONITORING:
TOTAL
TIME
LOCAL END
15:12:25
REMOTE END
15:12:25
(%)
LOCAL END
REMOTE END

EFS
100.00
100.00

NEGATIVE
0
AVAIL
TIME
15:12:25
15:12:25
ES
0.00
0.00

EFS

= ERROR FREE SECOND =

ES

= Error terjadi tiap 10

SES
0.00
0.00

UNAVAIL
TIME
00:00:00
00:00:00
DM
0.00
0.00

TRANSMI.OK ( normal kondisi = 100% )


6
3

bit perdetik ( normal kondisi = 0 )

= Error terjadi tiap 10 bit perdetik ( normal kondisi = 0 )


= Degradasi bit per menit setelah counter SES tinggi artinya sudah lebih
parah dari SES. ( normal kondisi = 0 )
Slip = ada perbedaan sinkronisasi antara near dan far end
Negatif maupun positif sama jelek ( normal kondisi = 0 )
Local = jika kita ukur di BSC terhadap TC maka rx BSCnya sebagai local dan
sebaliknya.
SES
DM

You might also like