Compressor Data Sheet: Atlas Copco

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 1

COMPRESSOR DATA SHEET

Rotary Compressor: Variable Frequency Drive


MODEL DATA - FOR COMPRESSED AIR
1

Manufacturer:

Atlas Copco

Model Number:

GA75VSD-175 AP

Air-cooled

Water-cooled

Oil-injected

Oil-free

Date:

6/15/2012

Type:

Screw

# of Stages:

Rated Operating Pressure

125

psigb

Drive Motor Nominal Rating

100

hp

Drive Motor Nominal Efficiency

94.2

percent

Fan Motor Nominal Rating (if applicable)

5.1

hp

Fan Motor Nominal Efficiency

83

Input Power (kW)

Capacity (acfm)

92.0
8*

Max

percent
Specific Power
(kW/100 acfm)d

488

18.9

72.4

382

19.0

56.6

293

19.3

41.9

207

20.2

28.3

127

22.3

Min

94

24.5

c, d

0.0

kW

23.0
9*

a,d

Total Package Input Power at Zero Flow


35.0

10

Specific Power
(kW/100 ACFM)

30.0

25.0

20.0

15.0

10.0
0

25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 525

Capacity (ACFM)
Note: Graph is only a visual representation of the data in Section 8
Note: Y-Axis Scale, 10 to 35, + 5kW/100acfm increments if necessary above 35
X-Axis Scale, 0 to 25% over maximum capacity

*For models that are tested in the CAGI Performance Verification Program, these items are verified by program administrator
Consult CAGI website for a list of participants in the third party verification program:
www.cagi.org
NOTES:
Member

a. Measured at the discharge terminal point of the compressor package in accordance with
ISO 1217, Annex E; acfm is actual cubic feet per minute at inlet conditions.
b. The operating pressure at which the Capacity and Electrical Consumption were measured for this data sheet.
c. No Load Power. In accordance with ISO 1217, Annex E, if measurement of no load power equals less than 1%,
manufacturer may state not significant or 0 on the test report.
d. Tolerance is specified in ISO 1217, Annex E, as shown in table below:
NOTE: The terms "power" and "energy" are synonymous for purposes of this document.
Volume Flow Rate
at specified conditions
m3 / min

ROT 031
10/11 R7

Volume Flow Rate

Specific Energy
Consumption

ft3 / min

Below 0.5

Below 15

+/- 7

+/- 8

0.5 to 1.5

15 to 50

+/- 6

+/- 7

1.5 to 15

50 to 500

+/- 5

+/- 6

Above 15

Above 500

+/- 4

+/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

No Load / Zero Flow


Power

+/- 10%