This document provides specifications for a flow meter installed for Customer FLOWQUIP. It details the maximum design flow rate of 26.5 cubic meters per hour, with a differential pressure of 725 kPa. The pipe is carbon steel, with a primary 316 stainless steel meter using restrictive orifice plate taps. Key measurements include a pressure of 750 kPa gauge and a temperature of 34 degrees Celsius.

Uploaded by

JasperTan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
380 views1 page

Restriction Orifice Final Calculation

This document provides specifications for a flow meter installed for Customer FLOWQUIP. It details the maximum design flow rate of 26.5 cubic meters per hour, with a differential pressure of 725 kPa. The pipe is carbon steel, with a primary 316 stainless steel meter using restrictive orifice plate taps. Key measurements include a pressure of 750 kPa gauge and a temperature of 34 degrees Celsius.

Uploaded by

JasperTan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

FMC TECHNOLOGIES

6 Baird Way
Thetford, Norfolk IP24 1JA
Tel: 01842 822900 Fax: 01842 765402
email:
Customer:FLOWQUIP
TAG
:RO44600
TAGFluid :DIESELOIL
Fluid Ref. :
Pipe
:Carbon Steel
Meter
:Pipe Taps, Restrictive Orifice
Coeff Eq :Miller/Stolz
Preparer :J.H.

PO
:
Doc
:
Sales Order#:
Service
:
Primary
:316 Stainless Steel
Taps
:2 1/2 & 8 D
Calculation :SIZE
Date
:08-20-2007

-----------------------------------------------------Max/Design/Normal---------------------------------------------Flow Rate
26.5000
m^3/h(Flow Volume)
Differential
725.0000
kPa
Pipe Reynolds Number
24519.
----------------------------------------------------------Measurements----------------------------------------------Pressure pG
750.0000
kPa,gage
Barometric
101.3250
kPa,abs
Temperature (Flowing)
34.0000
degC
--------------------------------------------------------Fluid Properties------------------------------------------------Density (Flowing)
850.00000
kg/m^3
Specific Gravity (GF)
0.85084
Viscosity
6.60000
cP
------------------------------------------------------------Factors-------------------------------------------------------Sizing Factor(SM)
0.09364
@ Normal Flow
Discharge Coefficient(C)
0.65966
@ Normal Flow
Pipe Thermal Expansion(FaD)
1.00015
Bore Thermal Expansion(Fad)
1.00023
---------------------------------------------Flow Meter Constant (for AGA/API C'=FMC)---------------------FMC=(m^3/h)/(dp)^ 0.5
0.9841
------------------------------------------------------Design Information---------------------------------------------Pipe Diameter(D)
49.2200
[email protected]
Bore Diameter
18.4507
mm@20. degC
Orifice plate thickness Minimum
Clamped
1.0420
mm@20. degC
Beta
0.3748
@20. degC
Pipeline Velocity (Max)
12.68
ft/s
Overall Pressure Loss(Max)
725.
kPa
Energy Cost
93500.
$/[email protected]/kwh

Meter is starting to cavitate


R.W. Miller and Associates, Inc. The FLOW CONSULTANT TM Licensed Software C1987-2007 Version 6.0.10