Isolated Square Footing Excel

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 9

GUAGUA NATIONAL COLLEG

GUAGUA, PAMPANGA
1-Jul-15

ISOLATED FOOTING PROGRAM


SQUARE FOOTING : CENTER COLUMN
Dungo, Allain Paul L.
Magsipoc, Renilo
Santos, Aldrin

INPUT DATA
DEAD LOAD
900
KN

fy
414

LIVE LOAD
1600
KN

DIAMETER OF STEEL
mPa

20

AREA OF COLUMN
x
480
480 mm

mm - RSB

Value added to thickness1


100

CONCRETE COVER
75

OUTPUT
FOOTING DIMENSIONS

------------------------

No. of steel bars

------------------------

PUNCHING SHEAR

-----------------------

3.7m
27pcs. of 20mm. RSB
1.41539462

BEAM SHEAR

-----------------------

0.49484792

DEVELOPMENT LENGTH

-----------------------

480.24

WEIGHT OF FOOTING

-----------------------

229.504

DESIGN OF SPREAD FOOTI


Total Loads

Determine the total loads


=

Determine the required area, footing length


Required area

Footing length
Estimate

=
=

Actual Area

Determine the PU and Net Ultimate Upwar


PU

NUSP

Analyze the Proportional Foot


Flexure
Pmin
W
Mmax

=
=
=

Thickness (d)
Assume

=
=

Area of Steel

No. Of Steel Bars


20mm. RSB

PUNCHING SHEAR
VPAll

VPact

CONDITION

HENCE SAFE
BEAM SHEAR

VAll

VActual

CONDITION

HENCE SAFE

CHECK FOR DEVELOPMENT LENG


Ldmin

Ldrequired

Ldfurnish

CONDITION

Wt. Of Footing
Wt.allowable
CONDITION

HENCE SAFE
CHECK WEIGHT OF FOOTING
=
=
REDESIGN

AGUA NATIONAL COLLEGES


GUAGUA, PAMPANGA

NG PROGRAM

ER COLUMN
Eng'r. Alfie Lejarde

*Input data on yellow cell

INPUT DATA
SOIL BEARING CAPACITY
200
kPa

f`c
20.7

WEIGHT OF CONCRETE
2300

kg/m

% Weight of Column
6

ue added to thickness1
100

desired thickness added to (d)

percentage difference to the actual area

OUTPUT
3.7m

pcs. of 20mm. RSB


<

Percentage of Area Required2


100
%

mPa

------------------------------------Thickness (d)

1.50141

------------

------------------------------------

13.690 mm2
658 mm.
HENCE SAFE

<

0.77345

<

543.15

<

150

------------------------------------<

1535 -----------

-------------------------------------

HENCE SAFE
HENCE SAFE
REDESIGN

OF SPREAD FOOTING (USD)


Determine the total loads
2650 KN

equired area, footing length and actual area


13.25 m2
3.64 m
3.70 m
0.658m

13.690 m2
3.7m

PU and Net Ultimate Upward Soil Pressure


3980 KN
290.72315559 KN/m2

3.7m

alyze the Proportional Footing


0.0033816425

3.7m

0.0676328502
1394129459 N*mm

Note: Mmax = MuCap

558.09476346 mm
658 mm
8232.9468599 mm2
26.219575987 ----------27pcs. of 20mm. RSB

PUNCHING SHEAR
1.5014093379 mPa
1.4153946205 mPa
HENCE SAFE
BEAM SHEAR
0.7734532953 mPa
0.4948479244 mPa
HENCE SAFE

HECK FOR DEVELOPMENT LENGTH


480.24 mm
543.15 mm
1535 mm
HENCE SAFE
CHECK WEIGHT OF FOOTING
229.504 KN
150 KN
REDESIGN