0% found this document useful (0 votes)
115 views1 page

Wind and Seismic Loading: Wind Load:: 8" CMU Wall W/ 6" Stone Veneer - 2 Side

This document provides wind and seismic load calculations for an 8-inch concrete masonry unit (CMU) wall with a 6-inch stone veneer. The wind load is calculated to be 13.78 pounds per square foot (psf) based on a basic wind speed of 70 miles per hour and exposure category C. The seismic load is calculated to be 36.61 psf based on equations from the California Building Code that consider factors like the wall's importance factor, response modification coefficient, and seismic weight. The calculated seismic load exceeds the minimum required by code.

Uploaded by

Ciprian Stelea
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
115 views1 page

Wind and Seismic Loading: Wind Load:: 8" CMU Wall W/ 6" Stone Veneer - 2 Side

This document provides wind and seismic load calculations for an 8-inch concrete masonry unit (CMU) wall with a 6-inch stone veneer. The wind load is calculated to be 13.78 pounds per square foot (psf) based on a basic wind speed of 70 miles per hour and exposure category C. The seismic load is calculated to be 36.61 psf based on equations from the California Building Code that consider factors like the wall's importance factor, response modification coefficient, and seismic weight. The calculated seismic load exceeds the minimum required by code.

Uploaded by

Ciprian Stelea
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

JOB

Drake Property

SHEET NO.
CALCULATED BY:

OF
cmc

DATE

CHECKED BY:

DATE

JOB NUMBER:

FILENAME

23-Jul-15

WIND AND SEISMIC LOADING: 8" CMU Wall w/ 6" Stone Veneer - 2 Side
WIND LOAD:

Per CBC 2001 Section 1618, 1619, 1620, 1622

Basic Wind Speed = 70 MPH


Exposure C

P = CeCqQsIw
Ce =
Cq =
Iw =
Qs =

1.06
1.30
1.00
10.00 psf
NOTE 1:

(Table 16-G)
(Table 16-H )
(Table 16-K)
(Table 16-F, Qs= 12.6 PSF )

For fences 12' or less in height, pressure may be reduced to 3/4 of Qs, but
not less than 10 psf per UBC Sec. 1624

Wind Loading Results

P=

13.78 psf

SEISMIC LOAD:

Per CBC 2001 Section 1634.5

V1 = .56Ca I W /1.4

Divided by 1.4 to obtain service loads

and not less than:

V2 =1.6 Z Nv Ip/R Wp/1.4


Rp =
Nv =
Na =
Ca =

Ip =
Wp =
Ca =
Z=

V1 =

3.00
1.00
1.00
0.44 Na
1.00
208.00 psf
0.44
0.40
36.61 psf

Divided by 1.4 to obtain service loads


(Table 16-P)
(Table 16-T)
(Per Sec. 1629.4.2) & Table 16-S
(Per Sec. 1630.2.3.2) & Table 16-Q
(Table 16-K)
8" CMU WALL (SOLID GROUT) & VENEER
(Table 16-I)

OK - V >1.6 Z Nv Ip/R Wp/1.4

Calculate Minimum Seismic Load per Sec. 1632.2

V2 =

31.70 psf

Seismic Loading Results

V=

36.61 psf

NOTE: Percentage of Seismic Load to Total Structure Weight Is 22%