Brayton Cycle

This document contains a calculation sheet for a Brayton power cycle. It provides inlet and outlet temperatures, pressures, and mass flow rates for the compressor and turbine. It also includes combustion calculations showing fuel and air ratios and combustion temperature. Power calculations show the turbine produces 114.4 MW of power and the total plant power is 189.95 MW.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
243 views4 pages

Brayton Cycle

This document contains a calculation sheet for a Brayton power cycle. It provides inlet and outlet temperatures, pressures, and mass flow rates for the compressor and turbine. It also includes combustion calculations showing fuel and air ratios and combustion temperature. Power calculations show the turbine produces 114.4 MW of power and the total plant power is 189.95 MW.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

Power Plant Calculation Sheet

Brayton Cycle Calculation Sheet


Unit
1 Point

Compressor

Turbine

Inlet (1)

Outlet (2)
100
1367.55
303.5
692.05

P (kPa)
T (K)
MW
Air
Fuel

Inlet (3)
Outlet (4)
1367.55
100
1319.559
782

P (kPa)
T (K)

mole

Flowrate
29 15.2827586 QAIR
16.848 0.46164398 QFUEL

443.2 kg/s
7.7777777778 kg/s

Combustion Calculation
Fuel & Air to Fuel Ratio
mole frac.

Combustion Temp.
COMB
TADIABATIC

mass frac.

28 ton/h

0.98

1332.365

CH4

(A)

0.9564

TINLETTURB

C2H6

(B)

0.0064

IdAir

CO2

(C)

0.0195

12.83952893 -155.2468 -90.66693 1818.053 -305.8244

N2

(D)

0.0177

0.9233983271 24.68366 33.75467 19.06406 31.51366

H2O

(E)

0.33

0.0001109065 0.026192 -0.003076 0.018131 -0.007391

1319.559
CO2
H2O

O2

N2

Air+Ex

360
d
4.69522E-009
-9E-006 7.65E-006
-1E-005 9.30E-006
(X)
-5.4877E-012 1.01E-009
-2E-009 2.41E-009
-3E-009
A/F
56.7658667
e
Note : Air + Excess (X) is a theoretical value. QAIR = A/F x QFUEL.
Entalpy &Work Calculation at Compressor
H
Cp(T )dt = M(a+bT+cT2+dT3+eT4)
H1
MAIR(a+bT1+(cT12)+(dT13)+(eT14))
303.39146462 kJ/kg
2
3
4
H2
MAIR(a+bT2+(cT2 )+(dT2 )+(eT2 ))
705.29160028 kJ/kg
W COMP
H2 - H1
401.90013566 kJ/kg
Entalpy &Work Calculation at Compressor
CO2
H2O
O2
MR
m
Cp
H3 (Gas)

61.0800509 114.422309

H2O

178122.1 kJ/s

N2

44
18
32
28
0.04442782 0.04158176 0.16443223 0.7495581917
Cp( TCO) dt Cp ( T ) dt Cp( TO) dt Cp ( TN ) dt Total
2

PCOMP

219.92159 1090.1419934 1485.566 kJ/kg

H4 (Gas)

31.5598435 62.8381856 122.893268 619.6577025 836.949 kJ/kg


56.7658667 G/A
1.01761622
(G/A)H3
1511.7360003 kJ/kg
H4 (Air)
(G/A)H4
PTURB
851.69287702 kJ/kg
W TURB
H4 - H3
660.04312324 kJ/kg
292531.1 kJ/s
PTURB - PCOMP
PBRAYTON
Power Calculation
114408.9721 kJ/s
114.409 MW
Em(kg/s) CO2
20.0372792 SO2
9.53408E-005 NO2
0.008803
A/F
H3 (Air)

Rankine Cycle Calculation Sheet


HRSG
ON
Heat Rate
TOUT-TURB
782 TOUT-HRSG
H4 (Gas)
G/A

9150 BTUIN/kWhOUT
373

836.948999 H4 (Air)
1.01761622 QAIR

851.692877

CO2

O2

H2O

H5 (Gas)

12.3693299 28.6987609

HHRSG

449.152649 kJ/kg

2.681601 kWhIN/kWhOUT
MW

443.2
N2

Total

56.407044 290.32121519 387.7963 kJ/kg


HHRSG(AIR) 457.06502121 kJ/kg

Sum
235424.8

(HHRSG/Heat Rate).QAIR
Power Calculation
PRANKINE
PTOTAL
75.54116 MW

75541.16 kJ/s

235425

189.9501 MW

TADIABATIC Calculation
TFUEL
TIN
R
HR
P
HP

298 TSTEAM
692.05 TADIABATIC

514

1332.365
CH4
C2H6
CO2
N2
H20
Air
-71459.15 -540.9216 -7676.3544
0 -77402.31 392503.5
CO2
H20
N2
O2
-337880 -455997 855457.403 173844.4726

You might also like