0% found this document useful (0 votes)
180 views2 pages

Vjti Pull Out Test Report

ekhfugvefbef

Uploaded by

Payal Chauhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
180 views2 pages

Vjti Pull Out Test Report

ekhfugvefbef

Uploaded by

Payal Chauhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 2
Telegram : “VUETINST” Matunga, Tel : 24198100 Ext 245/248/252 ‘Mumbai 400019 { PAX : 91-022-24152874 VEERMATA JIJABAL TECHNOLOGICAL INSTITUTE. (VITI) [Central Technological Institute, Maharashtra State] Matunga, Mumbai 400019 No /St/Con//pullout /Galbro /56/2014/57 | 2672_ 23-7-2014, 130 JUL 2014 To Galbro Ispat Galvanisers Pvt Ltd. 801, 8" Fl, Palm spring , Chincholl Bunder Unk Road , Malad (W) , Mumbai 400064. ‘Subject :Report on comparison between pullout strengths of Non galvanised (ordinary) and galvanized HYSD bar , by pullout test.. Reference No: Letter No.GIGPL/VITI/047-2014 dt 16-4-2014. Dear Sir, With reference to the above mer ned subject kindly find enclosed report on the same. Kindly feel free to discuss anything arising out of this report. Se Prof. P.W.ubde, 44.8 Bambole, DrOG Kakde , Project Coordinator, Structural Head, Structural Engineering Director, VITI. Engg, Deptt. iTI Department, VJTI Thanking you, ‘Yours faithfully, VEERMATA JLJABAL TECHNOLOGICAL INSTITUTE, MATUNGA, MUMBAI-400 019. STRUCTURAL ENGINEERING DEPARTMENT NoJ/SE/Conl/pullout /Galbro /56/2014/57 23-7-2014. Report on comparison between pullout strengths of Non galvanised (ordinary) and galvanized HYSD bar , by pullout test.. Tested for _: Galbro Ispat Galvanisers Pvt Ltd. , 801, 8" FI, Palm Spring , Chincholi Bunder , Link Read, Malad (W) , Mumbai 400064 Reference No: Letter No.GIGPL/VJTU047-2014 dt 16-4-2014. Project: To compare effect of galvanization on bond strength by pull out test , it was decided to cast cubs 6 cubes with A/C = 4.0 and W/C cubes with A/C = 4.0 and W/C = 0.45 with 16 mm diameter HYSD bars , 3 galvanised and 3 nongalvanised embedded into it to perform pull out tes. OBSERVATIONS AND RESULTS. 1. Average compressive strength of Cubes at 7 days, (N/mm?) :33.85 2. Average compressive strength of Cubes at 7 days. (N/mm?) :40.40 =0.45 to measure compressive strength and 6 Sr. No. Galvanized bars ‘Non galvanized Bars. Maximum load at | Slippage at | Maximum load at | Slippage at failure (KN) failure failure (KN) failure (mm) (mm) 1 121 25 120, 10 2 123 9 10 3 M8 M4 10 Type of failure | Bond gave up Bond gave up =a for all above. ‘Thus galvanized HYSD bars are found to give average 2.57% extra pull out strength as compared to non galvanized. HYSD bars. yor (Prof. PW Kubde) Project Coordinator.

You might also like