0% found this document useful (0 votes)
673 views1 page

Gas Line

This document provides guidelines for installing natural gas pipes underground and through exterior walls. It specifies that gas pipes installed in or under buildings must be placed inside gastight conduits or sleeves. The conduits and sleeves must be vented to the outside and sealed at the floor line and wall to prevent gas leaks. Access panels should also be included to allow removal or maintenance of underground gas lines. The guidelines aim to ensure subslab and exterior gas pipes are safely installed to code.

Uploaded by

ebbys89
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
673 views1 page

Gas Line

This document provides guidelines for installing natural gas pipes underground and through exterior walls. It specifies that gas pipes installed in or under buildings must be placed inside gastight conduits or sleeves. The conduits and sleeves must be vented to the outside and sealed at the floor line and wall to prevent gas leaks. Access panels should also be included to allow removal or maintenance of underground gas lines. The guidelines aim to ensure subslab and exterior gas pipes are safely installed to code.

Uploaded by

ebbys89
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Exterior Wall

FLEXIBLE NATURAL
GAS
LINE TO ISLAND
APPLIANCE

Island
Counter

Gas Pipe From Above


Rigid or CSST

Sealed to Sleeve
and Gas Pipe

Access Door

Connector
Sealed to Sleeve and Gas Pipe
Flex connection to Rigid Gas
Pipe at Access Door

Concrete Floor

Vent to Outside
Flexible Gas Pipe
Wardflex or Equal

ABS or PVC Sleeve, min. 1/2 inch Larger than Gas Pipe

Exterior Wall
Seal

Seal

Overhead Gas
Line to Meter

RIGID NATURAL
GAS
LINE TO ISLAND
APPLIANCE

Vented Access
Panel for Removal
of Gas Line

Watertight Cap

Sleeve to Exterior

ABS or PVC Sleeve, min. 1/2 inch Larger than Gas Pipe

SLAB CHASES
FOR
NATURAL GAS
PIPING

Pipe to
Conduit Seal

A. Provide channel or recess


in slab. Use removable cover
plate.
B. Pipe in conduit sealed at
floor line, with vent outside.

A
Vent

Seal

UPC 1211.4 No gas piping shall be installed in or on the ground


under any building or structure unless installed in gastight
conduit, and all exposed gas piping shall be kept at least six (6)
inches above grade or structure. The term "building or structure"
shall include structures such as porches and steps, whether
covered or uncovered, breezeways, roofed porte-cocheres,
roofed patios, carports, covered walks, covered driveways and
similar structures or appurtenances.