0% found this document useful (0 votes)
447 views

PSL

This document describes the mapping of digital data bus (DDB) signals for opto inputs, outputs, and logic functions in the MiCOM P443 programmable logic relay. It lists the DDB number and function for various circuit breaker states, protection elements, trip outputs, alarms, start signals, and LED indications. The mappings are used for internal logic, fault recording, and display on the LCD panel.

Uploaded by

maheshknm
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
447 views

PSL

This document describes the mapping of digital data bus (DDB) signals for opto inputs, outputs, and logic functions in the MiCOM P443 programmable logic relay. It lists the DDB number and function for various circuit breaker states, protection elements, trip outputs, alarms, start signals, and LED indications. The mappings are used for internal logic, fault recording, and display on the LCD panel.

Uploaded by

maheshknm
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

MiCOM P443 Programmable Logic

Opto Input Mappings

CB OPEN
DDB #034

CB CLOSE
DDB #035

CB Aux 3ph(52-B)
DDB #424

CB Aux 3ph(52-A)
DDB #420

LINE VT MCB TRIP


DDB #036

MCB/VTS
DDB #438

SOTF INIT LO&REM


DDB #037

Init Close CB
DDB #440

SPARE
DDB #038

External Trips:
Initiate Breaker Fail,
and Autoreclose (if
enabled).

CB Healthy
DDB #436

WEAK FEED
DDB #040

SPRAE
DDB #041

AR Enable
DDB #1384

SPARE
DDB #042

SPARE
DDB #043

Block CB AR
DDB #448

DIST RECV
DDB #044

Aided1 Scheme Rx
DDB #493

DEF RECV
DDB #045

Aided2 Scheme Rx
DDB #507

Trip Outputs are


generated by the
internal single/thre
phase trip
conversion logic

Block Zone 1 Gnd


DDB #384
Block Zone 1 Phs
DDB #385

BLOCK DIST/DEF
DDB #039

Block Zone 2 Gnd


DDB #386
Block Zone 2 Phs
DDB #387
Block Zone 3 Gnd
DDB #388
Block Zone 3 Phs
DDB #389
Block Zone P Gnd
DDB #390
Block Zone P Phs
DDB #391
Block Zone 4 Gnd
DDB #392
Block Zone 4 Phs
DDB #393
Inhibit IN>1
DDB #467

0
SPARE
DDB #004

Pick-Up
0

Page 1

ee

MiCOM P443 Programmable Logic


Output Contacts

Zone 1 Trip
DDB #608

Aid 1 Dist Trip


DDB #503

ZONE1 OPTD
DDB #017

Straight
0

Aid 2 Dist Trip


DDB #519

0
Zone 2 Trip
DDB #613

ZONE2 OPTD
DDB #018

Straight
0

0
Zone 3 Trip
DDB #618

ZONE3 OPTD
DDB #019

Straight
0

Zone 4 Trip
DDB #628

ZONE4&P OPTD
DDB #021

Straight

Zone P Trip
DDB #623

0
Aid 1 DEF Trip
DDB #505

DEF TRIP
DDB #023

Straight
0

WEAK FEED
DDB #040
Aided 1 Receive
DDB #494

&

WEAK FEED
DDB #040
Aided 2 Receive
DDB #508

DIST WEI ECHO


DDB #026

Straight

&

DEF WEI ECHO


DDB #028

Straight
0

.
Zone P A Start
DDB #753
Zone P B Start
DDB #754

DIST REV START


DDB #030

Straight

Zone P C Start
DDB #755

Zone P N Start
DDB #756

0
DEF Reverse
DDB #997

DEF REV START


DDB #031

Straight
0

Trip Output A
DDB #523
Trip Output B
DDB #524

0
AR INITIATION
DDB #003

Straight
Trip Output C
DDB #525

AR 3pole in prog
DDB #844
AR 1pole in prog
DDB #845

CB Succ 3P AR
DDB #852
CB Succ 1P AR
DDB #1571

Latching

FnKey LED6 Red


DDB #1050
FnKey LED6 Grn
DDB #1051

1
0

A/R Lockout
DDB #306
AR Blocked
DDB #859
AR In Service
DDB #1385

AR BLOCK
DDB #006

Straight
0

Page 2

MiCOM P443 Programmable Logic


Output Contacts

SG-opto Invalid
DDB #288
Prot'n Disabled
DDB #289
Static Test Mode
DDB #290
Test Loopback
DDB #291
Test IM64
DDB #292
VT Fail Alarm
DDB #293
CT Fail Alarm
DDB #294
Power Swing
DDB #297
CB Fail Alarm
DDB #298
CB Monitor Alarm
DDB #299
CB Mon LO Alarm
DDB #300
CB Status Alarm
DDB #301
CB Trip Fail
DDB #302
CB Close Fail
DDB #303
Man CB Unhealthy
DDB #304
No C/S Man Close
DDB #305
A/R Lockout
DDB #306

A/R CB Unhealthy
DDB #307
A/R No Checksync
DDB #308

General Alarm

Signalling Fail
DDB #311
IM64 SchemeFail
DDB #314
IEEE C37.94 Fail
DDB #315
Aid 1 Chan Fail
DDB #317
Aid 2 Chan Fail
DDB #318
F out of Range
DDB #319
InValid Mesg Fmt
DDB #333
Main Prot. Fail
DDB #334
Comms Changed
DDB #337
Battery Fail
DDB #352
Field Volts Fail
DDB #353
Max Prop. Alarm
DDB #338
Backup Usr Curve
DDB #371

Page 3

MiCOM P443 Programmable Logic


Output Contacts
0
Aided 1 Send
DDB #498

DIST SEND
DDB #000

Straight
0
0

Aided 2 Send
DDB #514

DEF SEND
DDB #001

Straight
0

Zone 1 Trip
DDB #608
Aid 1 Dist Trip
DDB #503

INST TRIP
DDB #002

Straight
0

Aid 1 DEF Trip


DDB #505

SOTF Trip Zone 1


DDB #709

LED6 Red
DDB #1034

Latching

LED6 Grn
DDB #1035

SOTF Trip Zone 2


DDB #710
SOTF Trip Zone 3
DDB #711

SOTF TRIP
DDB #024

Straight
0

SOTF Trip Zone 4


DDB #712
SOTF Trip Zone P
DDB #713

Zone 2 Trip
DDB #613
Zone 3 Trip
DDB #618

Zone 4 Trip
DDB #628

DELAYED TRIP
DDB #007

Straight

Zone P Trip
DDB #623

I>1 Trip
DDB #655
I>2 Trip
DDB #659
IN>1 Trip
DDB #671

1
0

IN>2 Trip
DDB #672

AIDED TRIP
DDB #022

Straight
0

Aid 1 Dist Trip


DDB #503

0
Aid 2 DEF Trip
DDB #521

CARR AIDED TRIP


DDB #015

Straight
0

0
Any Trip
DDB #522

GENERAL TRIP
DDB #020

Straight
0
0

Power Swing
DDB #297

PSB OPTD
DDB #029

Pick-Up
0

0
Aid1 WI Trip 3Ph
DDB #642

DIST WEI TRIP


DDB #025

Straight
0
0

Aid2 WI Trip 3Ph


DDB #652

DEF WEI TRIP


DDB #027

Straight
0

Page 4

MiCOM P443 Programmable Logic


LEDs

Any Trip
DDB #522

Latching

Zone 1 Trip
DDB #608

Latching

Zone 2 Trip
DDB #613
Zone 3 Trip
DDB #618

Zone P Trip
DDB #623

Zone 4 Trip
DDB #628

Latching

Latching

Aided 1 Receive
DDB #494

Latching

Aided 2 Receive
DDB #508

Latching

Aided 1 Send
DDB #498

Latching

Aided 2 Send
DDB #514

Latching

AR Blocked
DDB #859

Latching

P Swing Detector
DDB #1014

Power Swing
DDB #297
I>1 Trip
DDB #655

IN>1 Trip
DDB #671

Latching

Latching

I>2 Trip
DDB #659

LED2 Red
DDB #1026
LED2 Grn
DDB #1027
LED3 Red
DDB #1028
LED3 Grn
DDB #1029
LED4 Red
DDB #1030
LED4 Grn
DDB #1031
LED5 Red
DDB #1032
LED5 Grn
DDB #1033

FnKey LED1 Red


DDB #1040
FnKey LED1 Grn
DDB #1041

FnKey LED2 Red


DDB #1042
FnKey LED2 Grn
DDB #1043

FnKey LED3 Red


DDB #1044
FnKey LED3 Grn
DDB #1045

FnKey LED4 Red


DDB #1046
FnKey LED4 Grn
DDB #1047

FnKey LED5 Red


DDB #1048
FnKey LED5 Grn
DDB #1049

FnKey LED8 Red


DDB #1054
FnKey LED8 Grn
DDB #1055
LED7 Red
DDB #1036
LED7 Grn
DDB #1037

IN>2 Trip
DDB #672

VT Fail Alarm
DDB #293

Latching

LINE VT MCB TRIP


DDB #036

Aid1 WI Trip 3Ph


DDB #642

Non Latching

FnKey LED7 Red


DDB #1052
FnKey LED7 Grn
DDB #1053

FnKey LED9 Red


DDB #1056
FnKey LED9 Grn
DDB #1057

Aid2 WI Trip 3Ph


DDB #652

Any Trip
DDB #522

Fault REC TRIG


DDB #702

Page 5

Non Latching

FnKey LED10 Red


DDB #1058
FnKey LED10 Grn
DDB #1059

MiCOM P443 Programmable Logic


Zone 1 A Start
DDB #741

Start Phase Mappings.


Used in Fault Record &
on LCD Display

Zone 2 A Start
DDB #745

Zone 3 A Start
DDB #749

Zone P A Start
DDB #753

Zone 4 A Start
DDB #757

Started Phase A
DDB #956

I>1 Start A
DDB #762

DIST PH-A START


DDB #008

Pick-Up
0

I>2 Start A
DDB #766

Caution: Do Not
remove "Started
Phase" DDB
signals

I>3 Start A
DDB #770

I>4 Start A
DDB #774

Zone 1 B Start
DDB #742

Any Phase Start >> page7

Zone 2 B Start
DDB #746

Zone 3 B Start
DDB #750

Zone P B Start
DDB #754

Zone 4 B Start
DDB #758

Started Phase B
DDB #957

I>1 Start B
DDB #763

DIST PH-B START


DDB #009

Pick-Up
0

I>2 Start B
DDB #767

I>3 Start B
DDB #771

I>4 Start B
DDB #775

Zone 1 C Start
DDB #743

Zone 2 C Start
DDB #747

Zone 3 C Start
DDB #751

Zone P C Start
DDB #755

Zone 4 C Start
DDB #759

I>1 Start C
DDB #764

Started Phase C
DDB #958

0
DIST PH-C START
DDB #010

Pick-Up
I>2 Start C
DDB #768

I>3 Start C
DDB #772

I>4 Start C
DDB #776

Page 6

MiCOM P443 Programmable Logic


Zone 1 N Start
DDB #744

Any Ground Start >> page8

Zone 2 N Start
DDB #748

Zone 3 N Start
DDB #752

>>

>>

Zone P N Start
DDB #756

Zone 4 N Start
DDB #760

IN>1 Start
DDB #777

IN>2 Start
DDB #778

IN>3 Start
DDB #779

Started Phase N
DDB #959

IN>4 Start
DDB #780

ISEF>1 Start
DDB #781

ISEF>2 Start
DDB #782

ISEF>3 Start
DDB #783

ISEF>4 Start
DDB #784

Phase Select N
DDB #1013

&

Any Trip
DDB #522

>> page6 Any Phase Start

Any Phase Start >> page8

Phase Select N
DDB #1013

&
10

Any Trip
DDB #522

Pulse
0

This logic ensures correct N


indications for faults involving
ground. The pulse prevents pole
scatter affecting the N indication.

AR In Service
DDB #1385

N Phase Start >> page8 then page 9 then page 10

&

Reset Relays/LED
DDB #444

This reset controls:


Reset latched relays,
Reset latched LEDs,
Reset A/R Lockout.
This logic clears all latched indications at the
start of Any Trip

>
Page 7

MiCOM P443 Programmable Logic

> page7 Any Ground Start

> page7 Any Phase Start

>> page 7 N Phase Start

LED1 Red
DDB #1024

Latching

LED1 Grn
DDB #1025

Any Trip
DDB #522
I2>1 Start
DDB #567
I2>2 Start
DDB #568

Any Start
DDB #736

I2>3 Start
DDB #569

Used in Fault Record


initiation

I2>4 Start
DDB #570
V<1 Start
DDB #788

Caution: Do Not
remove "Any Start"
DDB signal

V<2 Start
DDB #792
V>1 Start
DDB #796
V>2 Start
DDB #800
VN>1 Start
DDB #804
VN>2 Start
DDB #805

F<1 Start
DDB #1155
F<2 Start
DDB #1156
F<3 Start
DDB #1157
F<4 Start
DDB #1158
F>1 Start
DDB #1159
F>2 Start
DDB #1160
V1>1 Cmp Start
DDB #923
V1>2 Cmp Start
DDB #924
df/dt>1 Start
DDB #597
df/dt>2 Start
DDB #598
df/dt>3 Start
DDB #599
df/dt>4 Start
DDB #600

N Phase Start >>page 9 then page 10


Page 8

>> pag

MiCOM P443 Programmable Logic

Zone 1 A Trip
DDB #609
Zone 2 A Trip
DDB #614
Zone 3 A Trip
DDB #619
Zone P A Trip
DDB #624
Zone 4 A Trip
DDB #629
Aided 1 Trip A
DDB #633
Aid 1 WI Trip A
DDB #637

Aided 2 Trip A
DDB #643

Faulted Phase A
DDB #952

Aid 2 WI Trip A
DDB #647
I>1 Trip A
DDB #656
I>2 Trip A
DDB #660
I>3 Trip A
DDB #664
I>4 Trip A
DDB #668
AR Trip Test A
DDB #577

Faulted Phase Flag, Used in


Fault record and on LCD
display.

AR Trip Test 3Ph


DDB #576

ge 7 then page 8 N Phase Start

Caution: Do Not remove


"Faulted Phase" DDB signals

Zone 1 B Trip
DDB #610
Zone 2 B Trip
DDB #615
Zone 3 B Trip
DDB #620
Zone P B Trip
DDB #625
Zone 4 B Trip
DDB #630
Aided 1 Trip B
DDB #634
Aid 1 WI Trip B
DDB #638
Aided 2 Trip B
DDB #644

Faulted Phase B
DDB #953

Aid 2 WI Trip B
DDB #648
I>1 Trip B
DDB #657
I>2 Trip B
DDB #661
I>3 Trip B
DDB #665
I>4 Trip B
DDB #669
AR Trip Test B
DDB #578
AR Trip Test 3Ph
DDB #576

N Phase Start >> page 10


Page 9

>> page 7

MiCOM P443 Programmable Logic

Zone 1 C Trip
DDB #611
Zone 2 C Trip
DDB #616
Zone 3 C Trip
DDB #621
Zone P C Trip
DDB #626
Zone 4 C Trip
DDB #631
Aided 1 Trip C
DDB #635
Aid 1 WI Trip C
DDB #639
Aided 2 Trip C
DDB #645

Faulted Phase
DDB #954

Aid 2 WI Trip C
DDB #649
I>1 Trip C
DDB #658
I>2 Trip C
DDB #662
I>3 Trip C
DDB #666
I>4 Trip C
DDB #670
AR Trip Test C
DDB #579

Faulted Phase Flag, Used in


Fault record and on LCD
display.

AR Trip Test 3Ph


DDB #576

Caution: Do Not remove


"Faulted Phase" DDB signals

Zone 1 N Trip
DDB #612
Zone 2 N Trip
DDB #617
Zone 3 N Trip
DDB #622
Zone P N Trip
DDB #627
Zone 4 N Trip
DDB #632
Aided 1 Trip N
DDB #636
Aided 2 Trip N
DDB #646
IN>1 Trip
DDB #671
IN>2 Trip
DDB #672

IN>3 Trip
DDB #673
IN>4 Trip
DDB #674
VN>1 Trip
DDB #700
VN>2 Trip
DDB #701
ISEF>1 Trip
DDB #675
ISEF>2 Trip
DDB #676
ISEF>3 Trip
DDB #677
ISEF>4 Trip
DDB #678

7 then page 8 the page 9 N Phase Start


Page 10

Faulted P
DDB

Phase N
#955

MiCOM P443 Programmable Logic


Inputs to Trip Conversion
Logic:These Raw trip signals
are then processed in relay fixed
logic, to obtain the correct
single, or three pole trip
response.

Zone 1 A Trip
DDB #609

Aided 1 Trip A
DDB #633

Aid 1 WI Trip A
DDB #637

Trip Inputs A
DDB #530

Aided 2 Trip A
DDB #643

Aid 2 WI Trip A
DDB #647

Caution: Do Not
remove "Trip Inputs"
DDB signals

AR Trip Test A
DDB #577

Zone 1 B Trip
DDB #610

Aided 1 Trip B
DDB #634

Aid 1 WI Trip B
DDB #638

Trip Inputs B
DDB #531

Trip Inputs C
DDB #532

Aided 2 Trip B
DDB #644

Aid 2 WI Trip B
DDB #648

AR Trip Test B
DDB #578

Zone 1 C Trip
DDB #611

Aided 1 Trip C
DDB #635

Aid 1 WI Trip C
DDB #639

Aided 2 Trip C
DDB #645

Aid 2 WI Trip C
DDB #649

AR Trip Test C
DDB #579

Page 11

MiCOM P443 Programmable Logic

pa

V<1 Trip
DDB #683
V<2 Trip
DDB #687
V>1 Trip
DDB #691
V>2 Trip
DDB #695
VN>1 Trip
DDB #700

Caution: Do Not
remove "Trip Inputs"
DDB signals

VN>2 Trip
DDB #701
F<1 Trip
DDB #1161
F<2 Trip
DDB #1162
F<3 Trip
DDB #1163

CBF Non I Trip


DDB #874

F<4 Trip
DDB #1164

Caution: Non
Current Protections
required to Initiate
CB Fail

F>1 Trip
DDB #1165
F>2 Trip
DDB #1166
df/dt>1 Trip
DDB #601
df/dt>2 Trip
DDB #602
df/dt>3 Trip
DDB #603
df/dt>4 Trip
DDB #604
V1>1 Cmp Trip
DDB #925
V1>2 Cmp Trip
DDB #926

AR Trip Test 3Ph


DDB #576
Broken Line Trip
DDB #679
Thermal Trip
DDB #680
I2>1 Trip
DDB #571
I2>2 Trip
DDB #572
I2>3 Trip
DDB #573
I2>4 Trip
DDB #574
ISEF>1 Trip
DDB #675

Trip Inputs 3Ph >> page 13


Caution: Do Not
remove "Trip Inputs"
DDB signals

ISEF>2 Trip
DDB #676
ISEF>3 Trip
DDB #677
ISEF>4 Trip
DDB #678
IREF> Trip
DDB #682

Page 12

MiCOM P443 Programmable Logic

age 12 >> Trip Inputs 3Ph


Stub Bus Trip
DDB #591
Pred. OST
DDB #551
OST
DDB #553
Zone 2 Trip
DDB #613
Zone 3 Trip
DDB #618
Zone P Trip
DDB #623
Zone 4 Trip
DDB #628
I>1 Trip
DDB #655
I>2 Trip
DDB #659
I>3 Trip
DDB #663
I>4 Trip
DDB #667
IN>1 Trip
DDB #671
IN>2 Trip
DDB #672
IN>3 Trip
DDB #673
IN>4 Trip
DDB #674
Aid1 Delta Tr3Ph
DDB #640
Aid1 DEF Trip3Ph
DDB #641
Aid1 WI Trip 3Ph
DDB #642
Aid2 Delta Tr3Ph
DDB #650
Aid2 DEF Trip3Ph
DDB #651
Aid2 WI Trip 3Ph
DDB #652

Trip Inputs 3Ph


DDB #529

Caution: Do Not
remove "Trip Inputs"
DDB signals

Loss ofLoad Trip


DDB #654
Pole Discrepancy
DDB #699
TOR Trip Zone 1
DDB #704
TOR Trip Zone 2
DDB #705
TOR Trip Zone 3
DDB #706
TOR Trip Zone P
DDB #708
TOR Trip Zone 4
DDB #707
TOR Trip CNV
DDB #557
SOTF Trip CNV
DDB #558
SOTF Trip Zone 1
DDB #709
SOTF Trip Zone 2
DDB #710
SOTF Trip Zone 3
DDB #711
SOTF Trip Zone P
DDB #713
SOTF Trip Zone 4
DDB #712

Page 13

Aid 1 Dist Trip


DDB #503
Aid 2 Dist Trip
DDB #519

Aid 1 DEF Trip


DDB #505
Aid 2 DEF Trip
DDB #521

CB Open A ph
DDB #904
CB Closed A ph
DDB #908

CB Open B ph
DDB #905
CB Closed B ph
DDB #909

CB Open C ph
DDB #906
CB Closed C ph
DDB #910

A/R Lockout
DDB #306

AR In Service
DDB #1385

CB ARIP
DDB #1544
CB Succ 3P AR
DDB #852
CB Succ 1P AR
DDB #1571

DIST PH-A START


DDB #008
DIST PH-B START
DDB #009

DIST PH-B START


DDB #009
DIST PH-C START
DDB #010

DIST PH-C START


DDB #010
DIST PH-A START
DDB #008

DIST 3PH START


DDB #014

Pick-Up

&

0
DIST PH AB START
DDB #011

Pick-Up

&

0
0

&

DIST PH BC START
DDB #012

Pick-Up

&

0
DIST PH CA START
DDB #013

Pick-Up
0