0% found this document useful (0 votes)
97 views1 page

1 2 Flex

The document describes a 1/2" flexible cable for transmitting power or signals. It has an inner conductor made of copper-clad aluminum rod surrounded by foam dielectric insulation. An outer corrugated copper conductor provides flexibility. The cable is jacketed in black LDPE for protection from UV rays. It lists the cable's mechanical and electrical parameters, such as impedance, attenuation at various frequencies, voltage ratings, and temperature ranges for operation and storage.

Uploaded by

microqual
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views1 page

1 2 Flex

The document describes a 1/2" flexible cable for transmitting power or signals. It has an inner conductor made of copper-clad aluminum rod surrounded by foam dielectric insulation. An outer corrugated copper conductor provides flexibility. The cable is jacketed in black LDPE for protection from UV rays. It lists the cable's mechanical and electrical parameters, such as impedance, attenuation at various frequencies, voltage ratings, and temperature ranges for operation and storage.

Uploaded by

microqual
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1/2” FLEX FEEDER CABLE

Description : The 1/2” Flexible cable is manufactured with inner conductor of Copper Clad Aluminium rod and outer corrugated copper
conductor to give flexibility to the cable. The inner conductor is insulated with foam dielectric having over high degree of foaming. The cable
is jacketed with Black LDPE jacketing compound to impart protection against UV rays.

Inner Copper Clad Aluminium Conductor


LDPE + HDPE Foam Insulation
Outer Corrugated copper Conductor

Jacket

Model No : MQT - 1/2F


Mechanical Parameters

Inner Conductor Copper Clad Aluminium Rod 4.8+/- 0.1 mm


Dielectric Foam Dielectric 11.9+/- 0.1 mm
Diameter Over Outer Conductor Corrugated Copper Tape 13.7 +/- 0.2mm
Diameter Over Outer Jacket PE 15.8 +/- 0.3 mm
Cable Weight 220 kg/km
Tensile Strength 1200 N
Minimum Bending Radius , Single Turn 70 mm
Minimum Bending Radius , Repeated 120 mm
Number of Bends , Minimum (Typical) 20 ( 50)
Bending Moment 5 Nm
Flat Plate Crush Strength 2kg/mm
Recommended Hanger Spacing 0.8 m
Installation Temperature Range -40 to + 60 Deg C
Operating Temperature Range -55 to + 85 Deg C
Storage Temperature Range -70 to + 85 Deg C

Electrical Parameters

Impedance 50 +/- 1 Ω Frequency Attenuation Mean Power


Relative Velocity of Propagation 88% MHz dB/100 M Rating
Insulation Resistance > 5G Ohm/k.m 100 2.17 3.52
Capacitance 75 pf/mt 200 3.10 2.47
Inductance 0.187 µH/mt 300 3.83 2.00
Maximum Operating Frequency 8.8 GHz 400 4.46 1.71
Cut Off Frequency 10.0 GHz 450 4.75 1.61
Peak Power Rating 40 KW 600 5.53 1.38
DC Break Down Voltage 4000 V 700 6.01 1.27
Jacket Spark , Volts RMS 8000 V 800 6.45 1.19
Inner Conductor DC Resistance 1.6 Ω / km 890 6.85 1.12
Outer Conductor DC Resistance 1.9 Ω / km 960 7.12 1.07
Return Loss 400 – 500 MHz 26 dB 1000 7.28 1.05
Return Loss 800 – 1000 MHz 26 dB 1500 9.09 0.84
Return Loss 1700 – 2200 MHz 26 dB 1700 9.74 0.78
Return Loss 2200 – 2700 MHz 26 dB 1800 10.10 0.76
VSWR 400 – 500 MHz 1.10 2000 10.70 0.71
VSWR 800 – 1000 MHz 1.10 2100 10.90 0.70
VSWR 1700 – 2200 MHz 1.10 2170 11.15 0.69
VSWR 2200 – 3000 MHz 1.10 2200 11.20 0.68
2300 11.50 0.66
2500 12.30 0.62
2700 12.80 0.60
3000 13.40 0.57
4000 15.80 0.48
5000 18.00 0.42
6000 20.10 0.38
8000 23.80 0.32
# Attenuation at 20 Deg C