Introduction To ZTE ZXUR9000 v4RNC and Dimensioning
Introduction To ZTE ZXUR9000 v4RNC and Dimensioning
Contents
RNC in UTRAN
Iub
RNC
ATM/IP Iu To CN
Iur To RNC
ZXWR RNC Hardware Architecture
Switch Unit
RAU (RNC Access Unit)
Node B
RAU
RSU
O&M Unit
ROMU APBE, EIPI, GIPI,SDTB, DTB,IMAB
Iur
RNC RSU (RNC Switch Unit)
Peripheral Monitor Unit
PSN, GLI, UIMC, GUIM and CHUB
RPMU
Iu RPU (RNC Processing Unit)
RCB, RUB
CN Power & Fan
RPMU( Peripheral Monitor Unit)
…
S
RCB Process RNC user plane (RUB)
U GLI N
CHUB GIPI, APBE
CLKG I
M Switch shelf
ROMB Main
UIMC
C Control Shelf Switch Shelf BPSN as Backboard
SBCX Supply switch unit for user plane
PSN, GLI
CHUB, ROMB,
CLKG only for
GIPI G main control Interface shelf
U shelf
APBE BGSN as Backboard
I SBCX only in
Main main resource DTB, SDTB, IMAB, EIPI, APBE
RUB M shelf
Resource Shelf
Control Shelf Configuration
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 CHUB, ROMB and CLKG
S R R R R R R U U R R C C C C 1 pair (1+1backup) for
B C C C C C C I I O O L L H H one RNC in the main
C B B B B B B M M M M K K U U
control shelf.
X C C B B G G B B
R R R R R R R R R Other control shelves
S U U M M C C C C only have UIMC, RCB or
V I I P P K K H H SBCX boards.
B M M B B G G B B
2 3 1 2 1 2
Backup
Name Full Name Configuration Principle
Principle
ROMB RNC Operating & Maintenance Board Each RNC 1 pair 1+1
RCB RNC Control plane processing Board BHCA & Cell & Sig Bandwidth 1+1
CHUB Control plane HUB Each RNC 1 pair 1+1
CLKG Clock Generator Each RNC 1 pair 1+1
Each RNC 3 pcs 1+1 for
SBCX X86 Single Board Computer
OMM: 2; Log Server: 1 OMM
UIMC Universal Interface Module of Control plane Each control shelf 1 pair 1+1
Board Dimensioning: RCB in Control Shelf
Processing
RCB Items Formula
capacity
Number of Cells 410 RCB_1=Number of Cells / 410
No. of BHCA 500K RCB_2 =No of BHCA / 500k
RCB_IpSig=Throughput of Signaling
Throughput of Signaling 14Mbps
/ 14Mbps
RCB and SBCX dimensioning principle
Detailed dimensioning principle with detailed traffic model:
RCB=2*MAX(RCB_1, RCB_2) + 2* RCB_IpSig
SBCX:
1 SBCX configured as log server, which will be put in main control shelf
2 SBCX configured as OMM server(1+1 backup), which can be put in
control or switch shelf.
Resource Shelf Configuration
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Each RNC has 2 GIPI
G G A A R R R R G G G G R R R R G (1+1) for OMCB in slot
I I P P U U U U U U I I U U U U I 11/12 of main resource
P P B B B B B B I I P P B B B B P shelf.
I I E E M M I I I
2 GUIM (1+1 backup)
R R R R R R R R R
for internal switching.
G G G G G G M M G
E E I I U U N N E
Providing interface
R R M M M M I I R
1 1 1 2 C C boards for IU interface.
Backup
Name Full Name Configuration Principle
Principle
RNC User plane
RUB Depends on user plan traffic model (CE) N+1
processing Board
Gigabit IP Load sharing
GIPI 1GE or 4FE, Throughput of each Interface
Interface or 1+1
ATM Process 4 ATM STM-1, Throughput of each Interface & ATM Load sharing
APBE
Board Enhanced STM-1 or 1+1
Universal Interface
GUIM Each Resource shelf 1 Pair 1+1
Module of User plane
Board Dimensioning: RUB in Resource Shelf
Voice Data
RUB number = ----------- + ----------
2100 165 Mbps (R99 64k)
265 Mbps (R99 384K)
Voice Data
RUB number = ----------- + ----------
2100 165 Mbps (R99 64k)
265 Mbps (R99 384K)