0% found this document useful (0 votes)
551 views20 pages

Introduction To ZTE ZXUR9000 v4RNC and Dimensioning

RNC Introduction and Configuration fir the ZXUR9000 V4 RNC •ZXWR RNC Introduction •ZXWR RNC Dimensioning Principle •ZXWR RNC Dimensioning Example

Uploaded by

bob_mirk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
551 views20 pages

Introduction To ZTE ZXUR9000 v4RNC and Dimensioning

RNC Introduction and Configuration fir the ZXUR9000 V4 RNC •ZXWR RNC Introduction •ZXWR RNC Dimensioning Principle •ZXWR RNC Dimensioning Example

Uploaded by

bob_mirk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

RNC Introduction and Configuration

Contents

• ZXWR RNC Introduction


• ZXWR RNC Dimensioning Principle
• ZXWR RNC Dimensioning Example
RNC Overview

RNC in UTRAN

Iub
RNC

ATM/IP Iu To CN

Iur To RNC
ZXWR RNC Hardware Architecture

RNC Hardware Logical Units


Iub ZXWR RNC
Process Unit  ROMU (RNC O&M unit)

RPU GPS ROMB, CLKG, SBCX


Access Unit

Switch Unit
 RAU (RNC Access Unit)
Node B
RAU

RSU
O&M Unit
ROMU APBE, EIPI, GIPI,SDTB, DTB,IMAB
Iur
RNC  RSU (RNC Switch Unit)
Peripheral Monitor Unit
PSN, GLI, UIMC, GUIM and CHUB
RPMU
Iu  RPU (RNC Processing Unit)

RCB, RUB
CN Power & Fan
 RPMU( Peripheral Monitor Unit)

PWRD: Power Distributor


STM-1 FE/GE
485 ALB: Alarm Board
E1
ZXWR RNC Features ZTE Large Capacity All-IP RNC

ZXWR RNC 2 Racks Capacity


 Modularity design, four types of shelves
Subscribers 1 Million  Control shelf
 Resource shelf
Traffic Vol. 52,500Erl
 Switch shelf
BHCA 7,000K  Interface shelf
 Rich interface: E1T1/FE/GE/STM-1/CSTM-1
Switch Capacity 80Gbps
Data Throughput 6,600 Mbps
Max. Node B 1,900
Max. Cell 5,700

Interface shelf can


expand
independently to
provide access
interface, easy for
future evolution to
IP UTRAN.
Contents

• ZXWR RNC Introduction


• ZXWR RNC Dimensioning Principle
• ZXWR RNC Dimensioning Example
ZXWR RNC System Structure
Control shelf
Control Signal  BCTC as Backboard
DTB G IMAB
Data Signal  Process RNC control plane (RCB)
SDTB U EIPI  ROMB,CLKG,CHUB,SBCX
I
APBE
M Resource shelf
Interface Shelf
GLI P  BGSN as Backboard


S
RCB  Process RNC user plane (RUB)
U GLI N
CHUB  GIPI, APBE
CLKG I
M Switch shelf
ROMB Main
UIMC
C Control Shelf Switch Shelf  BPSN as Backboard
SBCX  Supply switch unit for user plane
 PSN, GLI
 CHUB, ROMB,
CLKG only for
GIPI G main control Interface shelf
U shelf
APBE  BGSN as Backboard
I  SBCX only in
Main main resource  DTB, SDTB, IMAB, EIPI, APBE
RUB M shelf
Resource Shelf
Control Shelf Configuration
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17  CHUB, ROMB and CLKG
S R R R R R R U U R R C C C C 1 pair (1+1backup) for
B C C C C C C I I O O L L H H one RNC in the main
C B B B B B B M M M M K K U U
control shelf.
X C C B B G G B B
R R R R R R R R R  Other control shelves
S U U M M C C C C only have UIMC, RCB or
V I I P P K K H H SBCX boards.
B M M B B G G B B
2 3 1 2 1 2

Backup
Name Full Name Configuration Principle
Principle
ROMB RNC Operating & Maintenance Board Each RNC 1 pair 1+1

RCB RNC Control plane processing Board BHCA & Cell & Sig Bandwidth 1+1
CHUB Control plane HUB Each RNC 1 pair 1+1
CLKG Clock Generator Each RNC 1 pair 1+1
Each RNC 3 pcs 1+1 for
SBCX X86 Single Board Computer
OMM: 2; Log Server: 1 OMM

UIMC Universal Interface Module of Control plane Each control shelf 1 pair 1+1
Board Dimensioning: RCB in Control Shelf

Processing
RCB Items Formula
capacity
Number of Cells 410 RCB_1=Number of Cells / 410
No. of BHCA 500K RCB_2 =No of BHCA / 500k
RCB_IpSig=Throughput of Signaling
Throughput of Signaling 14Mbps
/ 14Mbps
RCB and SBCX dimensioning principle
 Detailed dimensioning principle with detailed traffic model:
 RCB=2*MAX(RCB_1, RCB_2) + 2* RCB_IpSig

 Simple dimensioning principle without detailed traffic model:


 RCB = RUB + RCB_IpSig
 RCB_IpSig =
2, if (RUB)<=4;
4, else (RUB)<=10;
6, else (RUB)>10;

Notes: RUB is user plane processing boards, of which dimensioning will be


introduced in following slide.

 SBCX:
 1 SBCX configured as log server, which will be put in main control shelf
 2 SBCX configured as OMM server(1+1 backup), which can be put in
control or switch shelf.
Resource Shelf Configuration
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17  Each RNC has 2 GIPI
G G A A R R R R G G G G R R R R G (1+1) for OMCB in slot
I I P P U U U U U U I I U U U U I 11/12 of main resource
P P B B B B B B I I P P B B B B P shelf.
I I E E M M I I I
 2 GUIM (1+1 backup)
R R R R R R R R R
for internal switching.
G G G G G G M M G
E E I I U U N N E
 Providing interface
R R M M M M I I R
1 1 1 2 C C boards for IU interface.

Backup
Name Full Name Configuration Principle
Principle
RNC User plane
RUB Depends on user plan traffic model (CE) N+1
processing Board
Gigabit IP Load sharing
GIPI 1GE or 4FE, Throughput of each Interface
Interface or 1+1
ATM Process 4 ATM STM-1, Throughput of each Interface & ATM Load sharing
APBE
Board Enhanced STM-1 or 1+1
Universal Interface
GUIM Each Resource shelf 1 Pair 1+1
Module of User plane
Board Dimensioning: RUB in Resource Shelf
Voice Data
RUB number = ----------- + ----------
2100 165 Mbps (R99 64k)
265 Mbps (R99 384K)

 Voice processing capacity is 2100.


 For different data server, the data throughput capacity is different.
GIPI & APBE Dimensioning
Interfaces Throughput Calculation

Iub BIub = BIubData + BlubSig

Iu-CS BIuCS = BIuCSData + BIuCSSig


Iu

Iu-PS BIuPS = BIuPSData + BIuPSSig

BIur= BIurData + BIurSig


Iur
BIurData = (BIuCSData + BIuPSData) * RIur

GIPI=IP interface throughput / 1Gbps

APBE=MAX (ATM interface throughput / 140Mbps, STM-1 Interface / 4)


Interface Shelf Configuration
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17  2 GUIM (1+1 backup)
(S) (S) I E (S) (S) I E G G (S) (S) I I (S) for internal switching.
D D M I D D M I U U D D M M D
T T A P T T A P I I T T A A T  Providing interface
B B B I B B B I M M B B B B B boards for IUB
R R R R R R R R R
D D D D G G D D D  Interface boards
T T T T U U T T T depend on networking
B B B B M M B B B
requirements.
1 2

Name Full Name Configuration Principle Backup Principle

DTB Digital Trunk Board 32E1, DTB = N_E1/32 Load sharing

SDTB SONET Digital Trunk Board 63E1, SDTB=N_E1/63 Load sharing/1+1

4 ATM STM-1, Throughput of each


APBE ATM Process Board Enhanced Load sharing/1+1
Interface & ATM STM-1

IMAB/ 1IMAB/EIPI + 2DTB,


IMA & EIPI Board Load sharing/1+1
EIPI 1IMAB/EIPI + 1SDTB
Interface boards dimensioning principle

 ATM over E1 : DTB + IMAB


 ATM over CSMT-1 : SDTB + IMAB
 IP over E1 : DTB + EIPI
 IP over CSTM-1: SDTB + EIPI
 ATM over STM-1: APBE
 FE/GE: GIPI

 IMAB dimensioning principle:


 2 DTB need 1 IMAB;
 1 SDTB need 1 IMAB;

 EIPI dimensioning principle:


 2 DTB need 1 EIPI;
 1 SDTB need 1 EIPI;
Switch Shelf Configuration
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17  Each GUIM has 2 GE,
G G G G G G P P U U each GLI has 4 GE.
L L L L L L S S I I
 1 GLI can connect two
I I I I I I N N M M
C C resource shelf or
R R
interface shelf.
U U
I I
M M
2 3

Name Full Name Configuration Principle Backup Principle

PSN Packet Switching Network 1 pair for switch shelf 1+1

GLI GE Line Interface 2 pairs GUIM need 1 pair GLI 1+1

Universal Interface Module of


UIMC 1 pair for switch shelf 1+1
Control plane
Contents

• ZXWR RNC Introduction


• ZXWR RNC Dimensioning Principle
• ZXWR RNC Dimensioning Example
RNC Dimensioning Example

Voice Data
RUB number = ----------- + ----------
2100 165 Mbps (R99 64k)
265 Mbps (R99 384K)

RUB= CEILING (5805/2100+388/200+92/200,1) = 6; After N+1 backup, RUB=8;

RCB = RUB + RCB_IpSig RCB Dimensioning Checking:


RCB_IpSig =
2, if (RUB)<=4; Cell Processing Capacity=4*420=1680
4, else (RUB)<=10; NodeB Processing Capacity=4*140=560
6, else (RUB)>10;

RCB = RUB+RCB_Ip Sig = 8+4 = 12;


RNC Dimensioning Result
IUB planning :

After 1+1 backup,


SDTB dimensioning result is 9+9;
APBE dimensioning result is 2+2;
GIPI dimensioning result is 2+2;

GLI Dimensioning result:


Resource shelf + Interface shelf=5
GLI=6;